{"product_id":"abb-1sda071901r1-e6-2v-5000-ekip-dip-li-4p-f-hr","title":"ABB 1SDA071901R1 E6.2V 5000 Ekip Dip LI 4p F HR 150kA Air Circuit Breaker","description":"\u003cp\u003eABB order code 1SDA071901R1 covers the E6.2V 5000 Ekip Dip LI 4p F HR air circuit breaker — a non-withdrawable, 4-pole SACE Emax 2 unit rated 5000 A with a 150 kA breaking capacity at 400 V AC, fixed to the panel with rear horizontal terminals and protected by the Ekip Dip LI electronic release up to 690 V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA071901R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE6.2V 5000 Ekip Dip LI 4p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644757519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e888 x 371 x 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Pole Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50% of Iu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e483 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In = Iu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated \/ Operational Voltage (Ur = Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity (Icu = Ics, 100%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA (400-440 V AC) | 130 kA (500-525 V AC) | 100 kA (690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA for 1 s \/ 100 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear flat horizontal, bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis fixed E6.2V unit, rated 5000 A with 150 kA breaking capacity, bolts directly to rear horizontal busbars. Its Ekip Dip LI release covers only L (overload, long-time), I (instantaneous), with no settable short-time delay. That makes it a faster-clearing choice for outgoing feeder positions where selective coordination with a smaller breaker is not required. Where the installation needs the breaker to ride through a downstream fault for selectivity, the Ekip Dip LSI sibling at the same 5000 A rating adds that S-function delay. The V performance level pushes Icu to 150 kA at 400-440 V AC (dropping to 130 kA at 500-525 V and 100 kA at 690 V), a step above the H-class sibling's flat 100 kA across the same voltage range — worth the difference only where the prospective fault current at this busbar actually exceeds 100 kA. The fourth pole switches the neutral at 50% of the phase rated current, sized for TN systems where neutral unbalance load stays well below the phase loading.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228973076763,"sku":"1SDA071901R1","price":18173.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda071901r1-e6-2v-5000-ekip-dip-li-4p-f-hr-air-circuit-breaker.jpg?v=1790957299","url":"https:\/\/stoklink.com\/products\/abb-1sda071901r1-e6-2v-5000-ekip-dip-li-4p-f-hr","provider":"Stoklink","version":"1.0","type":"link"}