{"product_id":"abb-1sda071692r1-e2-2n-2500-ekip-dip-lsi-4p-f-hr-acb","title":"ABB 1SDA071692R1 E2.2N 2500 Ekip Dip LSI 4p F HR 2500A 4P 66kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA071692R1 — catalog number \u003cstrong\u003eE2.2N 2500 Ekip Dip LSI 4p F HR\u003c\/strong\u003e — is a 2500A, 4-pole, fixed-mount air circuit breaker from the SACE Emax2 E2.2 series, featuring the Ekip Dip LSI trip unit with a breaking capacity of 66 kA at 400 V AC. Designed for demanding low-voltage power distribution applications, it delivers precise LSI (Long-time, Short-time, Instantaneous) protection in a robust fixed (F) horizontal rear (HR) withdrawable format, making it a reliable backbone for industrial and commercial switchgear installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N 2500 Ekip Dip LSI 4p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA071692R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax2 E2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644755423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal Rear (HR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e366 mm × 371 mm × 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir Circuit Breaker (ACB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical equipment safety and EMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC international standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Complies with IEC 60947 low-voltage switchgear and controlgear standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed to UL 2799 for electrical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Suitable for use in potentially explosive atmospheres per ATEX directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and approved by VDE (Verband der Elektrotechnik) for German\/European markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation for chemical substance management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and tie circuit breakers in low-voltage main distribution boards (MDB)\u003c\/li\u003e\n\u003cli\u003eIndustrial switchgear panels and power distribution centers\u003c\/li\u003e\n\u003cli\u003eGenerator protection and bus-tie applications\u003c\/li\u003e\n\u003cli\u003eCommercial building main distribution up to 2500 A\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations requiring ATEX compliance\u003c\/li\u003e\n\u003cli\u003eData center and critical infrastructure power distribution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228961575195,"sku":"1SDA071692R1","price":5632.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda071692r1-e2-2n-2500-ekip-dip-lsi-4p-f-hr-4p-f-hr_8b5c0b9b-6b3f-4148-998b-44de85ba86cf.webp?v=1777184732","url":"https:\/\/stoklink.com\/products\/abb-1sda071692r1-e2-2n-2500-ekip-dip-lsi-4p-f-hr-acb","provider":"Stoklink","version":"1.0","type":"link"}