{"product_id":"abb-1sda071602r1-e2-2h-1250-ekip-dip-lsi-4p-f-hr","title":"ABB 1SDA071602R1 E2.2H 1250 Ekip Dip LSI 4p F HR 100kA Air Circuit Breaker","description":"\u003cp\u003eBuilt as a four-pole fixed-mount breaker with rear horizontal terminals, the ABB 1SDA071602R1 is a SACE Emax 2 E2.2H 1250 Ekip Dip LSI air circuit breaker rated 1250 A. It reaches a 100 kA breaking capacity (Icu) at 400 V AC and an 85 kA short-time withstand (Icw) for 1 s, with the LSI release enabling selective tripping ahead of downstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eE2.2H 1250 Ekip Dip LSI 4p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e1SDA071602R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2 (E2.2 frame, performance level H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8015644754525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral Pole Current\u003c\/td\u003e\n\u003ctd\u003e100% of Iu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu \/ In)\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e12 kV, acc. to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 400-440 V AC; 85 kA at 500-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-440 V AC; 85 kA at 500-690 V AC (100% of Icu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e85 kA for 1 s, 66 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease \/ Trip Unit\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LSI (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eRear flat, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Capacity\u003c\/td\u003e\n\u003ctd\u003e1200 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e83 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e366 x 371 x 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for IT Networks\u003c\/td\u003e\n\u003ctd\u003eYes, up to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fourth pole on this fixed, rear-horizontal breaker switches the neutral, distinguishing it from the three-pole version for four-wire 690 V AC installations. The LSI release's short-time delay stage supports selective coordination with downstream breakers ahead of the instantaneous trip. At 1250 A, Icu reaches 100 kA at 400 V AC with an 85 kA Icw for 1 s.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228972290331,"sku":"1SDA071602R1","price":4417.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda071602r1-e22h-1250-ekip-dip-lsi-4p-f-hr-acb.jpg?v=1790953980","url":"https:\/\/stoklink.com\/products\/abb-1sda071602r1-e2-2h-1250-ekip-dip-lsi-4p-f-hr","provider":"Stoklink","version":"1.0","type":"link"}