{"product_id":"abb-1sda071221r1-e4-2v-4000-ekip-dip-li-3p-f-hr","title":"ABB 1SDA071221R1 E4.2V 4000 Ekip Dip LI 3p F HR 150kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA071221R1 is a fixed, three-pole SACE Emax 2 E4.2V air circuit breaker with rear horizontal terminals, rated for the highest breaking-capacity class in the E4.2 frame. Fitted with an Ekip Dip LI release, it withstands 4000 A continuously and breaks up to 150 kA (Icu) at 400 V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA071221R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE4.2V 4000 Ekip Dip LI 3p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644750718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In \/ Iu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Breaking Capacity (Icu, 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Breaking Capacity (Ics, 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA (100% of Icu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA for 1 s \/ 75 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear flat Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for IT Networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e465 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e384 × 371 × 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003e1SDA071221R1 uses an Ekip Dip LI release - long-time overload (L) plus instantaneous (I) only, with no adjustable short-time delay stage - so it clears a short circuit as soon as the instantaneous threshold is crossed rather than holding off for selective coordination with a downstream device. That trade-off comes with the V performance class, the highest in the E4.2 frame at 150 kA Icu and 100 kA Icw for 1 s, which suits it to high-fault-level incomers where clearing speed matters more than staged selectivity. The fixed, rear horizontal (F HR) terminals bolt straight to busbars; choose the LSI-release variant instead when the installation needs the adjustable short-time stage for coordination.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228916125979,"sku":"1SDA071221R1","price":9062.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda071221r1-e4-2v-4000-ekip-dip-li-3p-f-hr-air-circuit-breaker.jpg?v=1790953954","url":"https:\/\/stoklink.com\/products\/abb-1sda071221r1-e4-2v-4000-ekip-dip-li-3p-f-hr","provider":"Stoklink","version":"1.0","type":"link"}