{"product_id":"abb-1sda071191r1-e4-2n-4000-ekip-dip-li-3p-f-hr-acb","title":"ABB 1SDA071191R1 E4.2N 4000 Ekip Dip LI 3p F HR 4000A 3P 66kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA071191R1 — catalog number \u003cstrong\u003eE4.2N 4000 Ekip Dip LI 3p F HR\u003c\/strong\u003e — is a 4000 A, 3-pole fixed-mount air circuit breaker from the SACE Emax2 E4.2 series, delivering a breaking capacity of 66 kA at 400 V AC for demanding low-voltage power distribution applications. Equipped with the Ekip Dip LI electronic trip unit, this open-type ACB provides precise long-time (L) and instantaneous (I) overcurrent protection in a robust HR (High Rated) frame, making it an authoritative choice for main switchboards, incoming feeders, and bus-coupler positions in industrial and infrastructure installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE4.2N 4000 Ekip Dip LI 3p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA071191R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax2 E4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE4.2N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644750411\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI (Long-time \u0026amp; Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHR (High Rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir Circuit Breaker (ACB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e384 mm × 371 mm × 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC 60947-2 for low-voltage circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed to UL 2799, covering electrical systems for electric drive vehicles and industrial switchgear applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Suitable for use in environments with explosive atmosphere requirements per ATEX directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements for industrial electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and verified by VDE (Verband der Elektrotechnik), Germany's leading electrical engineering standards body\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive (2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substance safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incoming and bus-coupler positions in low-voltage main distribution boards (MDBs)\u003c\/li\u003e\n  \u003cli\u003eFeeder protection in large industrial plants, data centres, and infrastructure facilities\u003c\/li\u003e\n  \u003cli\u003eGenerator and transformer outgoing protection where high rated current and breaking capacity are critical\u003c\/li\u003e\n  \u003cli\u003eSwitchgear panels requiring a fixed-mount, open-type ACB with electronic trip unit flexibility\u003c\/li\u003e\n  \u003cli\u003eOil \u0026amp; gas, petrochemical, and mining installations requiring ATEX-compliant switchgear\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228912587035,"sku":"1SDA071191R1","price":6916.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda071191r1-e4-2n-4000-ekip-dip-li-3p-f-hr-3p-f-hr_4c470a2b-9c47-48a2-8b21-af3932f4aab0.webp?v=1777184610","url":"https:\/\/stoklink.com\/products\/abb-1sda071191r1-e4-2n-4000-ekip-dip-li-3p-f-hr-acb","provider":"Stoklink","version":"1.0","type":"link"}