{"product_id":"abb-1sda070971r1-e2-2h-1250-ekip-dip-li-3p-f-hr","title":"ABB 1SDA070971R1 E2.2H 1250 Ekip Dip LI 3p F HR 100kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA070971R1 is a SACE Emax 2 E2.2H 1250 Ekip Dip LI three-pole air circuit breaker, fixed version with rear horizontal terminals. The H performance level pushes breaking capacity (Icu) to 100 kA at 400 V AC, with an 85 kA short-time withstand (Icw) for 1 s. Rated at 1250 A, it suits high-fault-level 690 V AC installations needing maximum short-circuit performance from the E2.2 frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Designation\u003c\/td\u003e\n\u003ctd\u003eE2.2H 1250 Ekip Dip LI 3p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e1SDA070971R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2 (E2.2 frame, performance level H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8015644748210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Uninterrupted Current (Iu \/ In)\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e12 kV, acc. to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 400-440 V AC; 85 kA at 500-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e100 kA at 220-440 V AC; 85 kA at 500-690 V AC (100% of Icu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e85 kA for 1 s, 66 kA for 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease \/ Trip Unit\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Performance Level\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eRear flat, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Capacity\u003c\/td\u003e\n\u003ctd\u003e1200 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e83 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e276 x 371 x 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for IT Networks\u003c\/td\u003e\n\u003ctd\u003eYes, up to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe H performance level pushes Icu to 100 kA at 400 V AC - more than double the 42 kA of the E2.2B frame - making this 1250 A breaker suited to installations with high prospective fault current. The LI release trips instantaneously on overcurrent without a short-time delay stage; an LSI-equipped version is the alternative where selective coordination with downstream breakers is needed. Fixed, rear-horizontal terminals mean no separate cradle is required.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228914585883,"sku":"1SDA070971R1","price":3236.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda070971r1-e22h-1250-ekip-dip-li-3p-f-hr-acb.jpg?v=1790953877","url":"https:\/\/stoklink.com\/products\/abb-1sda070971r1-e2-2h-1250-ekip-dip-li-3p-f-hr","provider":"Stoklink","version":"1.0","type":"link"}