{"product_id":"abb-1sda070951r1-e2-2n-1250-ekip-dip-li-3p-f-hr-acb","title":"ABB 1SDA070951R1 E2.2N 1250 Ekip Dip LI 3p F HR 1250A 3P 66kA Air Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA070951R1 E2.2N 1250 Ekip Dip LI 3p F HR is a 1250 A, 3-pole fixed-mount air circuit breaker from the SACE Emax2 E2.2 series, delivering a breaking capacity of 66 kA at 400 V AC. The E2.2N 1250 Ekip Dip LI 3p F HR features ABB's Ekip Dip trip unit with Long-time (L) and Instantaneous (I) protection functions, making it a robust solution for low-voltage power distribution and switchgear panel applications requiring high fault-current interruption capability.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N 1250 Ekip Dip LI 3p F HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA070951R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax2 E2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2.2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644748012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir Circuit Breaker (ACB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI (Long-time + Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal Rear (HR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e276 mm × 371 mm × 270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with applicable EU directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Directive 2015\/863 amending REACH substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS 2 hazardous substances restriction directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2015\/863:\u003c\/strong\u003e RoHS 3 amendment extending restricted substance list\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC standards for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed under UL's electrical waste reduction standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Suitable for use in potentially explosive atmospheres per ATEX directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Approved to VDE standards for electrical safety (Germany)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomer protection in low-voltage main distribution boards (MDB)\u003c\/li\u003e\n\u003cli\u003eBus-coupler and feeder protection in industrial switchgear panels\u003c\/li\u003e\n\u003cli\u003eGenerator and transformer secondary protection\u003c\/li\u003e\n\u003cli\u003ePower distribution in petrochemical, oil \u0026amp; gas, and mining plants (ATEX rated)\u003c\/li\u003e\n\u003cli\u003eData centre and critical infrastructure main switchgear\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228911178011,"sku":"1SDA070951R1","price":2414.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda070951r1-e2-2n-1250-ekip-dip-li-3p-f-hr-3p-f-hr_b2bb6492-901f-49e7-8c55-dbb7f569dc4e.webp?v=1777184498","url":"https:\/\/stoklink.com\/products\/abb-1sda070951r1-e2-2n-1250-ekip-dip-li-3p-f-hr-acb","provider":"Stoklink","version":"1.0","type":"link"}