{"product_id":"abb-1sda070821r1-e1-2b-1250-ekip-dip-li-3p-f-f-acb","title":"ABB 1SDA070821R1 E1.2B 1250 Ekip Dip LI 3p F F 1250A 3P 42kA Fixed Air Power Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA070821R1, catalog number \u003cstrong\u003eE1.2B 1250 Ekip Dip LI 3p F F\u003c\/strong\u003e, is a 1250A 3-pole fixed-mount air power circuit breaker from the SACE Emax2 E1.2 series, delivering a breaking capacity of 42 kA at 400 V AC for reliable protection of transformers, generators, and electrical installations. Equipped with the Ekip Dip LI (Long-time and Instantaneous) protective release unit, the E1.2B 1250 Ekip Dip LI 3p F F provides precise overcurrent coordination in demanding industrial power distribution systems. Weighing 14 kg with compact dimensions of 210 mm × 296 mm × 183 mm, this breaker is engineered for high-density control panels and switchgear assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE1.2B 1250 Ekip Dip LI 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA070821R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax2 E1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644746711\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtective Release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI (Long-time \/ Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm × 296 mm × 183 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir Power Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union low-voltage and electromagnetic compatibility directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC 60947-2 for low-voltage circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed to UL 2799 standard for electrical system safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in potentially explosive atmospheres per ATEX directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and approved by Verband der Elektrotechnik (VDE), Germany\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive (2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered and compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incoming protection for transformers up to and including medium-scale industrial substations\u003c\/li\u003e\n  \u003cli\u003eGenerator circuit breaker and back-up protection in standby and prime-power installations\u003c\/li\u003e\n  \u003cli\u003eBusbar and feeder circuit protection in low-voltage main distribution switchboards (MDB)\u003c\/li\u003e\n  \u003cli\u003eIndustrial plant power distribution in manufacturing, oil \u0026amp; gas, mining, and utilities sectors\u003c\/li\u003e\n  \u003cli\u003eData centre and critical infrastructure power supply protection requiring high breaking performance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228908425499,"sku":"1SDA070821R1","price":2156.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda070821r1-e1-2b-1250-ekip-dip-li-3p-f-f-air-circuit-breakers_3221844d-5160-443b-ad08-19c200d8377e.webp?v=1777184458","url":"https:\/\/stoklink.com\/products\/abb-1sda070821r1-e1-2b-1250-ekip-dip-li-3p-f-f-acb","provider":"Stoklink","version":"1.0","type":"link"}