{"product_id":"abb-1sda067575r1-xt2s-160-tma-40-400-4p-f-f-mccb","title":"ABB 1SDA067575R1 XT2S 160 TMA 40-400 4p F F 40A 4-Pole Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA067575R1 XT2S 160 TMA 40-400 4p F F is a 4-pole, 40 A fixed moulded case circuit breaker from ABB's Tmax XT2 series, engineered for reliable protection of transformers, generators, and distribution installations. The XT2S 160 TMA 40-400 4p F F features a thermomagnetic TMA release with an adjustable current range of 40–400 A, delivering precise overload and short-circuit protection in demanding industrial environments. Compact, robust, and compliant with IEC 60947-2, this MCCB is a trusted choice for panel builders and electrical engineers worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXT2S 160 TMA 40-400 4p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA067575R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXT2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644014711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMA (Thermomagnetic Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Setting Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40–400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 220 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified to German electrotechnical standards (Verband der Elektrotechnik)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres per EU ATEX directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU — restriction of hazardous substances in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS recast directive covering hazardous substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU RoHS amendment extending substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard compliance for electrical construction products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive (2012\/19\/EU)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTransformer primary and secondary circuit protection\u003c\/li\u003e\n\u003cli\u003eGenerator feeder and output protection\u003c\/li\u003e\n\u003cli\u003eMain and sub-distribution board incoming protection\u003c\/li\u003e\n\u003cli\u003eIndustrial control panel feeder circuits\u003c\/li\u003e\n\u003cli\u003eMotor feeder protection in combination with suitable overload relays\u003c\/li\u003e\n\u003cli\u003eApplications requiring ATEX-rated circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229060108571,"sku":"1SDA067575R1","price":154.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda067575r1-xt2s-160-tma-40-400-4p-f-f-4p-f-f_002cf6ac-b194-46c3-943b-d7f5e86c5be7.webp?v=1777393457","url":"https:\/\/stoklink.com\/products\/abb-1sda067575r1-xt2s-160-tma-40-400-4p-f-f-mccb","provider":"Stoklink","version":"1.0","type":"link"}