{"product_id":"abb-1sda067091r1-xt2n-160-ekip-dip-ls-i-in-25a-4p-f-f","title":"ABB 1SDA067091R1 XT2N 160 Ekip Dip LS\/I In=25A 4p F F 36kA Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe XT2N 160 Ekip Dip LS\/I In=25A 4p F F, ABB 1SDA067091R1, is a fixed four-pole Tmax XT2 moulded case circuit breaker in the 160 A N-class frame, with its Ekip Dip LS\/I electronic release set to 25 A. Icu reaches 36 kA at 415 V AC, Short-Circuit Performance Level N, matching the breaker to feeders sized around a 25 A overload point.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA067091R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXT2N 160 Ekip Dip LS\/I In=25A 4p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub-type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644009960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Setting (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Uninterrupted Current (Iu, frame)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue\/Ur)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LS\/I, electronic (EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kA (220-240 V AC) \/ 36 kA (380-440 V AC) \/ 30 kA (500 V AC) \/ 20 kA (525 V AC) \/ 10 kA (690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esame as Icu for this variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Performance Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity Main Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 32.5-100 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, Bolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpening Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ms (with SOR) \/ 30 ms (with UVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 25 A setting sits a step above the lowest In adjustment on this XT2N 160 frame, suiting slightly larger feeders while keeping the same 36 kA Icu at 415 V AC N-class rating. Because the setting is adjustable within the release, confirm the actual load current before fixing the trip point rather than assuming the frame's 160 A nameplate rating applies.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229063909659,"sku":"1SDA067091R1","price":422.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda067091r1-xt2n-160-ekip-dip-ls-i-25a-mccb.png?v=1790959318","url":"https:\/\/stoklink.com\/products\/abb-1sda067091r1-xt2n-160-ekip-dip-ls-i-in-25a-4p-f-f","provider":"Stoklink","version":"1.0","type":"link"}