The ABB 1SCA152411R1001 (OXB1000E3X2QB) is a 3-pole, 1000 A TruONE automatic transfer switch with a Level 2 DIP-switch controller and bottom-supply, top-load line terminals, built for systems with a solidly bonded neutral. It is rated 200-480 V AC (+/-20%), withstands 65 kA for 0.1 s, and switches with an open-style, delayed I-O-II transition.
Dropping to 3 poles removes the switched neutral the 4-pole 'S' units carry, so this X-coded switch suits systems with a solidly bonded, non-switched neutral rather than one that must transfer with the phases. Its Level 2 DIP-switch controller handles basic transfer logic without a display, and the QB layout brings supply in from the bottom. Move to the 4-pole frame if the installation needs the neutral to switch along with the phases.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Degree of Protection | Front IP20 |
|---|---|
| Pollution Degree | 3 |
| Product Net Width | 597 mm, 23.5 in |
|---|---|
| Product Net Height | 359 mm, 14.13 in |
| Product Net Depth / Length | 212 mm, 8.35 in |
| Product Net Weight | 31.14 kg, 68.65 lb |
| Part number | 1SCA152411R1001 |
|---|---|
| Type designation | OXB1000E3X2QB |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 6417019833927 |
| ETIM class | EC000216 |
| eCl@ss | 27371403 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Controller Type | Level 2 (DIP) |
|---|---|
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 1000 A |
| Handle Type | Direct Mount |
| Number of Poles | 3P |
| Position of Line Terminals | Supplies on Bottom - Load on Top |
| Power Loss | at Rated Operating Conditions per Pole 14 W, Total 42 W |
| Rated Frequency (f) | Main Circuit 50-60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-31B (Ie) | (200 … 415 V AC) 1000 A |
| Rated Operational Current AC-32B (Ie) | (200 … 415 V AC) 1000 A |
| Rated Operational Current AC-33B (Ie) | (200 … 415 V AC) 1000 A |
| Rated Operational Voltage | Main Circuit 200...480 V AC |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 65 kiloampere rms |
| Special Functions | Open style |
| Standards | IEC60947-6-1 |
| Terminal Type | Bolt |
| Transition Type | Delayed |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
|---|---|
| eClass | V11.1 : 27371403 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 430 mm, 16.93 in |
| Package Level 1 Depth / Length | 690 mm, 27.17 in |
| Package Level 1 Height | 450 mm, 17.72 in |
| Package Level 1 Gross Weight | 44.14 kg, 97.31 lb |
| Package Level 1 EAN | 6417019833927 |
| Shipping weight | 31.14 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of OXB1000E3X2QB is 1000 A.
The rated operational voltage of OXB1000E3X2QB is 200–480 V AC.
The tariff (HS) code on file for OXB1000E3X2QB is 853650.
The EAN (GTIN) of OXB1000E3X2QB is 6417019833927.
OXB1000E3X2QB ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
How phase-sequence, voltage/frequency and temperature monitoring relays let an ATS safely transfer a load onto a standby generator and back.