{"product_id":"abb-1sca151028r1001-oxb500e3x2qt","title":"ABB 1SCA151028R1001 OXB500E3X2QT 500A 3P 42kA Automatic Transfer Switch","description":"\u003cp\u003eABB's 1SCA151028R1001 (OXB500E3X2QT) is a 500 A TruONE open-style automatic transfer switch with 3-pole switching for standby and backup-power circuits. The 200-480 V AC rated unit pairs a Level 2 DIP controller with a 42 kA (0.1 s) short-time withstand current and a delayed I-O-II transfer sequence. Line terminals are top-fed.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB500E3X2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA151028R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE Automatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current AC-31B (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A (200-415 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw, 0.1 s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 kA rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Free-air Thermal Current (Ith at 40°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLevel 2 (DIP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelayed (open style, I-O-II operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePosition of Line Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplies on Top - Load on Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.2 W per pole, 51.6 W total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e447 x 313 x 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019812854\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3-pole configuration switches only the phase conductors and leaves the neutral solid, which fits three-wire distribution or installations where the neutral is bonded elsewhere and does not need to follow the transfer; pick the 4-pole (S) version instead when the system requires the neutral to open with the phases. The Level 2 DIP controller is configured through on-board switches, appropriate where transfer parameters are set once at commissioning. Top-fed line terminals (QT) suit panels wired with incoming supply above the switch; pick the QB variant instead when busbars feed in from below. For higher continuous-current duty, the 630 A frame in the same OXB TruONE range covers loads this 500 A unit does not.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229232599323,"sku":"1SCA151028R1001","price":2941.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca151028r1001-oxb500e3x2qt-automatic-transfer-switch.png?v=1790958171","url":"https:\/\/stoklink.com\/products\/abb-1sca151028r1001-oxb500e3x2qt","provider":"Stoklink","version":"1.0","type":"link"}