{"product_id":"abb-1sca022872r1680-ot1000e03cp","title":"ABB 1SCA022872R1680 OT1000E03CP 3P 1000V 50kA Manual Change-Over Switch Changeover Switch","description":"\u003cp\u003eThe ABB OT1000E03CP (SKU 1SCA022872R1680) is a 1000 A, 3-pole manual change-over switch rated for a 1000 V main circuit, built around an open-transition pistol handle with a 50 kA 1-second short-time withstand current (Icw). It mounts to the base of an enclosure and switches between two incoming sources without an automatic control board.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No\u003c\/td\u003e\n\u003ctd\u003eOT1000E03CP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SCA022872R1680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eManual Change-over Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e6417019338989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Main Circuit)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free-air Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current AC-23A (Ie)\u003c\/td\u003e\n\u003ctd\u003e1000 A (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Power AC-23A (Pe)\u003c\/td\u003e\n\u003ctd\u003e560-1000 kW (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e50 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eFront IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eBase mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition of Line Terminals\u003c\/td\u003e\n\u003ctd\u003eTop In - Bottom Out \/ Bottom In - Top Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransition Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss per Pole\u003c\/td\u003e\n\u003ctd\u003e19 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e400 x 306 x 309 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the 3-pole OT1000E03CP where the neutral conductor is unswitched and solidly connected in both source positions — common on TN-C-S distribution boards. The 50 kA Icw rating sets the maximum upstream fault current the switch can survive for 1 second while an upstream breaker clears a fault, so size the upstream protection device within that limit. A 4-pole version of the same frame is available where the neutral itself must transfer with the switch.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229275525403,"sku":"1SCA022872R1680","price":1745.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022872r1680-ot1000e03cp-change-over-switch.jpg?v=1790956940","url":"https:\/\/stoklink.com\/products\/abb-1sca022872r1680-ot1000e03cp","provider":"Stoklink","version":"1.0","type":"link"}