{"product_id":"abb-1sca022872r1500-ot1000e04cp","title":"ABB 1SCA022872R1500 OT1000E04CP 4P 1000V 50kA Manual Change-Over Switch Changeover Switch","description":"\u003cp\u003eABB's OT1000E04CP (SKU 1SCA022872R1500) is a 1000 A, 4-pole manual change-over switch for a 1000 V main circuit. Its fourth pole switches simultaneously with the other three, so the neutral transfers along with the phases, and its open-transition pistol handle carries a 50 kA, 1-second Icw rating for base mounting in an enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No\u003c\/td\u003e\n\u003ctd\u003eOT1000E04CP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e1SCA022872R1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eManual Change-over Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e6417019338972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFourth Pole Type\u003c\/td\u003e\n\u003ctd\u003eSwitched - Simultaneous Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage (Main Circuit)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free-air Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current AC-23A (Ie)\u003c\/td\u003e\n\u003ctd\u003e1000 A (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Power AC-23A (Pe)\u003c\/td\u003e\n\u003ctd\u003e560-1000 kW (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short-time Withstand Current (Icw)\u003c\/td\u003e\n\u003ctd\u003e50 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eFront IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eBase mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransition Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss per Pole\u003c\/td\u003e\n\u003ctd\u003e19 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e42.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e480 x 306 x 309 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the 4-pole OT1000E04CP over its 3-pole counterpart when the neutral must switch together with the phases — typical for generator changeover, where an unswitched neutral would create a parallel earth path between two sources. The open-transition design breaks the first source before making the second, so downstream equipment sees a brief interruption rather than a momentary parallel connection. Its 50 kA Icw matches the 3-pole variant, so frame and fault-current sizing are unaffected by the pole-count choice.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229276967195,"sku":"1SCA022872R1500","price":1822.18,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022872r1500-ot1000e04cp-change-over-switch.jpg?v=1790956931","url":"https:\/\/stoklink.com\/products\/abb-1sca022872r1500-ot1000e04cp","provider":"Stoklink","version":"1.0","type":"link"}