{"product_id":"abb-1sbl407001r1111-af96-30-11-11-130a-power-contactor","title":"ABB 1SBL407001R1111 AF96-30-11-11 3-Pole 130A 1000V AC 45kW AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF96-30-11-11 (SKU: 1SBL407001R1111) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 130 A (AC-1) and 1000 V IEC, this AF-series contactor delivers 45 kW at 400 V AC (AC-3) and is suitable for demanding motor control and load switching duties. Its wide-range coil accepts 24–60 V AC (50\/60 Hz) or 20–60 V DC, simplifying integration across diverse control voltage systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF96-30-11-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL407001R1111\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL, 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed for North American safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA certified for Canadian market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Safety of household and similar appliances — heat pumps, air conditioners (UL listing ref: LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian equivalent for heat pump and air conditioning applications (listing ref: LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health and environmental directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA standard for contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Harmonised IEC and European low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Harmonised IEC and European standard for contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear — standardised mounting on DIN rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for reliability and durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e General CSA Canadian electrical standard compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e3-phase motor control and switching in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration systems (UL 60335-2-40 \/ CSA C22.2 No. 60335-2-40 approved)\u003c\/li\u003e\n  \u003cli\u003eControl panels and motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003ePump and compressor control in water treatment and process industries\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore applications (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding services and infrastructure control\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229137932571,"sku":"1SBL407001R1111","price":239.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl407001r1111-af96-30-11-11-contactor-ac-switching_0b2da9a7-f5ec-40f5-9e48-d7ebcd6d66c4.jpg?v=1777156990","url":"https:\/\/stoklink.com\/products\/abb-1sbl407001r1111-af96-30-11-11-130a-power-contactor","provider":"Stoklink","version":"1.0","type":"link"}