{"product_id":"abb-1sbl397201r1300-af80-40-00-13-125a-4pole-power-contactor","title":"ABB 1SBL397201R1300 AF80-40-00-13 4-Pole 125A 1000V AC 37kW Power Contactor AC Switching 100-250V Coil","description":"\u003cp\u003eThe ABB AF80-40-00-13 power contactor (SKU: 1SBL397201R1300) is a 4-pole AC switching contactor rated at 125 A (AC-1) and up to 1000 V IEC, delivering 37 kW at 400 V AC (AC-3) for demanding industrial motor and load switching applications. The AF80-40-00-13 features a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), making it highly versatile for global installations across diverse control voltage systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF80-40-00-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL397201R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133730\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 x 150 x 103 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU directives for safety and electromagnetic compatibility\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — listed for North American safety standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — approved for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — approved for the South Korean market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping — approved for marine use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for Canadian market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4 \/ IEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL standard for safety of HVAC equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:22:\u003c\/strong\u003e CSA standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA standard for HVAC safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA safety standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked standby products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-91:\u003c\/strong\u003e Supplementary standard for energy efficiency assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant with SVHC substance restrictions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free of restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation systems up to 37 kW \/ 400 V AC-3\u003c\/li\u003e\n  \u003cli\u003eHVAC compressor and fan motor control in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical switchboards (DNV, LR, RMRS approved)\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty load switching in control panels for manufacturing and process industries\u003c\/li\u003e\n  \u003cli\u003eGlobal installations requiring multi-standard certification (IEC, UL, CSA, CCC, KC)\u003c\/li\u003e\n  \u003cli\u003eResistive and capacitive load switching (AC-1) up to 125 A \/ 1000 V IEC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229159428379,"sku":"1SBL397201R1300","price":187.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl397201r1300-af80-40-00-13-switching-100-250v-coil_cf0010c2-a902-4e19-9600-285ef04a9e59.webp?v=1777156985","url":"https:\/\/stoklink.com\/products\/abb-1sbl397201r1300-af80-40-00-13-125a-4pole-power-contactor","provider":"Stoklink","version":"1.0","type":"link"}