{"product_id":"abb-1sbl397001r1311-af80-30-11-13-125a-3p-contactor","title":"ABB 1SBL397001R1311 AF80-30-11-13 3-Pole 125A 1000V AC-1 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF80-30-11-13 (SKU: 1SBL397001R1311) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 125 A (AC-1) and up to 1000 V IEC, it delivers 37 kW at 400 V AC (AC-3) with a wide-range 100–250 V AC\/DC coil, making it highly versatile across global installations. Part of ABB's AF series, this contactor combines robust performance with a compact 82 × 125.5 × 116 mm footprint and a weight of just 1.21 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF80-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL397001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3 @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — equivalent to CE for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL 60335-2-40 — UL Listed under file LZGH2A2L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e Contactors and motor-starters (UL standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA C22.2 No. 60335-2-40 — CSA certified under LZGH2A2L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules (CSA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e Contactors and motor-starters (CSA standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC CB Scheme — internationally recognised safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and industrial type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor starting and switching in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and pump control (AC-3 duty)\u003c\/li\u003e\n\u003cli\u003eControl panel integration for manufacturing machinery\u003c\/li\u003e\n\u003cli\u003eHeating and resistive load switching (AC-1 duty)\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS\/BV approved)\u003c\/li\u003e\n\u003cli\u003eGlobal deployments requiring UL\/CSA\/CE\/CCC multi-certification\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the coil voltage range for the AF80-30-11-13?\u003c\/strong\u003e The coil accepts 100–250 V AC\/DC at 50\/60 Hz, eliminating the need for multiple coil variants across different supply voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat auxiliary contacts are included?\u003c\/strong\u003e The AF80-30-11-13 configuration includes 1 NO + 1 NC auxiliary contacts (as indicated by the -11-13 designation).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this contactor suitable for UL-listed installations?\u003c\/strong\u003e Yes. It is UL Listed (UL 60947-4-1, UL 60335-2-40) and CSA certified, rated at 105 A general use and 60 hp at 480 V for North American applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated power for motor applications?\u003c\/strong\u003e 37 kW at 400 V AC under AC-3 duty (IEC), and 60 hp at 480 V (UL).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229127905563,"sku":"1SBL397001R1311","price":148.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl397001r1311-af80-30-11-13-contactor-ac-switching_359d8eb2-2da6-4976-a2d4-ce44a4b43901.jpg?v=1777156980","url":"https:\/\/stoklink.com\/products\/abb-1sbl397001r1311-af80-30-11-13-125a-3p-contactor","provider":"Stoklink","version":"1.0","type":"link"}