{"product_id":"abb-1sbl397001r1111-af80-30-11-11-125a-3p-contactor","title":"ABB 1SBL397001R1111 AF80-30-11-11 3-Pole 125A AC-1 37kW 400V Coil 24-60V AC\/DC Contactor","description":"\u003cp\u003eThe ABB AF80-30-11-11 contactor (SKU 1SBL397001R1111) is a 3-pole industrial power contactor rated 125 A AC-1 and 37 kW at 400 V (AC-3), designed for demanding motor switching and load control applications. Part of ABB's AF Series, the AF80-30-11-11 accepts a wide-range coil voltage of 24–60 V AC (50\/60 Hz) and 20–60 V DC, enabling flexible integration across international control systems without the need for multiple coil variants.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF80-30-11-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL397001R1111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 \/ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL \/ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1, AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety and EMC requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certificate for global market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Safety of household and commercial electrical appliances — heat pumps, HVAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian equivalent for HVAC\/heat pump appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear, general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for AC electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL file reference for HVAC appliance certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA file reference for HVAC appliance certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA standard for AC contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrotechnical products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e General CSA electrical safety standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substance safety (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase AC motor switching and direct-on-line (DOL) motor starting up to 37 kW \/ 400 V\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and fan motor control in commercial and industrial buildings\u003c\/li\u003e\n\u003cli\u003ePump and conveyor motor control in process industries\u003c\/li\u003e\n\u003cli\u003eResistive and inductive load switching in industrial automation panels\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS, BV approved)\u003c\/li\u003e\n\u003cli\u003eNorth American applications requiring UL\/CSA listed 60 hp \/ 480 V contactors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229136097563,"sku":"1SBL397001R1111","price":184.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl397001r1111-af80-30-11-11-24-60v-ac-dc-contactor_68b1a86f-ee10-4cc8-b885-b62d7a703cfe.jpg?v=1777156975","url":"https:\/\/stoklink.com\/products\/abb-1sbl397001r1111-af80-30-11-11-125a-3p-contactor","provider":"Stoklink","version":"1.0","type":"link"}