{"product_id":"abb-1sbl347001r1311-af40-30-11-13-contactor","title":"ABB 1SBL347001R1311 AF40-30-11-13 3-Pole 70A AC-1 18.5kW 690V 100-250V Coil AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF40-30-11-13 (SKU: 1SBL347001R1311) is a 3-pole AC power contactor from ABB's AF series, rated at 70 A AC-1 and 690 V IEC, delivering 18.5 kW at 400 V AC-3 for robust industrial AC switching applications. Featuring a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), the AF40-30-11-13 simplifies installation and reduces spares inventory across diverse control systems. Compact dimensions of 67 × 125.5 × 111 mm and a lightweight 0.99 kg profile make it ideal for high-density panel layouts in industrial automation and motor control centres.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF40-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL347001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 mm × 125.5 mm × 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523132139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL (UL 60335-2-40):\u003c\/strong\u003e UL-listed per UL 60335-2-40 for safety of electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL-certified per low-voltage switchgear general rules standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL-certified per contactors and motor starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA (CSA C22.2 No. 60335-2-40):\u003c\/strong\u003e CSA-certified per Canadian safety standard for electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA-certified per low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA-certified per contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA certification per safety of household electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA certification per low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-4:\u003c\/strong\u003e International standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-5:\u003c\/strong\u003e International standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European standard for enclosure protection degrees (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability of electrical and electronic products to be repaired, reused, and upgraded\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-91:\u003c\/strong\u003e Supplementary European standard for repairability and upgradability assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval for marine and offshore use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB scheme certification — international mutual recognition of safety test results\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — required for sale in China\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment — compliant with EU Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control centres (MCC) for 3-phase induction motors up to 18.5 kW \/ 400 V\u003c\/li\u003e\n  \u003cli\u003eHVAC systems — compressor and fan motor switching including A2L refrigerant equipment\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and process control panels\u003c\/li\u003e\n  \u003cli\u003ePump stations and conveyor drive control\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and energy management systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229127545115,"sku":"1SBL347001R1311","price":76.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl347001r1311-af40-30-11-13-contactor-ac-switching_964d0429-e744-4f9b-b306-9a9b78c8ef97.jpg?v=1777156935","url":"https:\/\/stoklink.com\/products\/abb-1sbl347001r1311-af40-30-11-13-contactor","provider":"Stoklink","version":"1.0","type":"link"}