{"product_id":"abb-1sbl296001r2100-af38z-30-00-21-50a-3p-contactor","title":"ABB 1SBL296001R2100 AF38Z-30-00-21 3-Pole 50A 690V AC 24-60V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF38Z-30-00-21 (SKU: 1SBL296001R2100) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 50 A and up to 690 V IEC (600 V UL), the AF38Z-30-00-21 delivers reliable motor switching up to 18.5 kW at 400 V AC (AC-3) or 25 hp at 480 V UL, with a wide-range coil accepting 24–60 V AC 50\/60 Hz and 20–60 V DC. Its compact 45 × 86 × 86 mm footprint and lightweight 0.35 kg construction make it ideal for space-constrained control panels and machine automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF38Z-30-00-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL296001R2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523114715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU low voltage and EMC directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for voluntary product quality assurance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA safety standard for heat pumps and air conditioners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for the North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard equivalent to IEC 60947-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard equivalent to IEC 60947-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL standard for HVAC equipment with A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for AC contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA standard for HVAC with A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC and EN standard for low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC and EN standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Supplementary energy efficiency standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA safety requirements for household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association general compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant with substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — lead-free and compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor starting and switching in industrial machinery and production lines\u003c\/li\u003e\n\u003cli\u003eHVAC compressor control with A2L refrigerant compatibility\u003c\/li\u003e\n\u003cli\u003eControl panel integration in factory automation and building management systems\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations requiring ABS, BV, or DNV approval\u003c\/li\u003e\n\u003cli\u003eOEM machine builders requiring compact, globally certified contactors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229140947227,"sku":"1SBL296001R2100","price":86.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl296001r2100-af38z-30-00-21-contactor-ac-switching_b79254fd-93de-4cb3-a756-c4c28553a4ea.webp?v=1777156908","url":"https:\/\/stoklink.com\/products\/abb-1sbl296001r2100-af38z-30-00-21-50a-3p-contactor","provider":"Stoklink","version":"1.0","type":"link"}