{"product_id":"abb-1sbl157001r1310-af12-30-10-13-power-contactor","title":"ABB 1SBL157001R1310 AF12-30-10-13 3-Pole 12A 690V AC 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12-30-10-13 power contactor (SKU: 1SBL157001R1310) is a 3-pole AC switching contactor rated at 28 A and 690 V IEC, designed for demanding industrial motor control and switching applications. Part of ABB's versatile AF-series lineup, the AF12-30-10-13 features a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), eliminating the need for multiple coil variants across global installations. Rated at 5.5 kW at 400 V AC (AC-3) and 7-1\/2 hp at 480 V UL, this compact contactor fits tightly in control panels with dimensions of only 45 mm × 86 mm × 77 mm and a lightweight 0.27 kg body.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12-30-10-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL157001R1310\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110335\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC (IEC) \/ 600 V (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-1\/2 hp @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliance for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed — Underwriters Laboratories safety certification for North America\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for heat pumps, air-conditioners, and dehumidifiers (ref: LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified — Canadian Standards Association approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 (LZGH2A2L):\u003c\/strong\u003e CSA standard for HVAC switching equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA household and commercial electrical equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA low-voltage switchgear and controlgear standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary quality standard for electrical products in China\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore equipment certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification and certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme (IEC System for Conformity Testing) — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — mechanical shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle and recover electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary assessment standard for recyclability and recoverability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHVAC systems — air-conditioners, heat pumps, compressors, and fans\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor belt motor control\u003c\/li\u003e\n  \u003cli\u003ePump and compressor on\/off switching in process industries\u003c\/li\u003e\n  \u003cli\u003eOEM control panels requiring compact, globally certified contactors\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations (ABS\/BV certified)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229123744027,"sku":"1SBL157001R1310","price":18.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl157001r1310-af12-30-10-13-contactor-ac-switching_5080cbad-1186-441e-b89c-1162048edbd1.webp?v=1777156812","url":"https:\/\/stoklink.com\/products\/abb-1sbl157001r1310-af12-30-10-13-power-contactor","provider":"Stoklink","version":"1.0","type":"link"}