{"product_id":"abb-1sbl156001r2110-af12z-30-10-21-contactor","title":"ABB 1SBL156001R2110 AF12Z-30-10-21 3-Pole 28A 690V 24-60V AC\/DC Coil AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12Z-30-10-21 power contactor (SKU: 1SBL156001R2110) is a 3-pole AC switching contactor rated at 28 A and 690 V, designed for demanding industrial motor control and automation applications. Part of ABB's proven AF series, this contactor features a wide-range coil accepting 24–60 V AC (50\/60 Hz) and 20–60 V DC, enabling flexible integration across diverse control voltage architectures. Compact at 45 × 86 × 77 mm and weighing only 0.31 kg, the AF12Z-30-10-21 delivers reliable switching performance at up to 5.5 kW.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12Z-30-10-21\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL156001R2110\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523113510\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V AC 50\/60 Hz \/ 20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping approved\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC CB Scheme certification for international market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Standard for household and similar electrical appliances — heating and cooling equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL listing under file LZGH2A2L\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian standard for heating and cooling equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA listing under file LZGH2A2L\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e Canadian standard series for electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e Canadian standard series for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 (IEC60947-4):\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 (IEC60947-5):\u003c\/strong\u003e Control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715 (IEC60715):\u003c\/strong\u003e Dimensions of low-voltage switchgear for DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529 (IEC60529):\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 (IEC60947-1):\u003c\/strong\u003e Low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e General methods for assessing the recyclability and recoverability of energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets UK post-Brexit market requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starting and stopping in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment control including compressors and fan motors up to 5.5 kW\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor system switching\u003c\/li\u003e\n  \u003cli\u003ePump and compressor control in process industries\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and facility management systems\u003c\/li\u003e\n  \u003cli\u003eReversing starter configurations when paired with a second contactor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229139931419,"sku":"1SBL156001R2110","price":28.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl156001r2110-af12z-30-10-21-contactor-ac-switching_b817318f-9164-4f79-bfd6-ac47263b7a7a.webp?v=1777156784","url":"https:\/\/stoklink.com\/products\/abb-1sbl156001r2110-af12z-30-10-21-contactor","provider":"Stoklink","version":"1.0","type":"link"}