{"product_id":"abb-1sap187100r0004-ta5122-2ai-tc","title":"ABB 1SAP187100R0004 TA5122-2AI-TC 2-Channel 16-Bit Thermocouple Input PLC I\/O Module","description":"\u003cp\u003eThe ABB TA5122-2AI-TC (order code 1SAP187100R0004) is an analog input option board for AC500-eCo PLCs. It reads 2 thermocouple channels covering types B, E, J, K, N, R, S and T at 16-bit resolution, with spring terminals included, giving the CPU direct temperature-sensor input without an external signal converter. The board ships with the required spring terminals, so no separate connector part is needed when wiring the eight supported thermocouple types.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder code\u003c\/td\u003e\n\u003ctd\u003e1SAP187100R0004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType code\u003c\/td\u003e\n\u003ctd\u003eTA5122-2AI-TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC500-eCo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4013614561450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e2 AI: Thermocouple B, E, J, K, N, R, S, T. 16-bit. Spring terminals included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eThermocouple (TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (analog input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Configurable I\/Os\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.021 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e0.035 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e54.2 x 28.5 x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the TA5122-2AI-TC when an application needs direct thermocouple input across the B, E, J, K, N, R, S and T types at 16-bit resolution. For RTD sensors, the TA5123-2AI-RTD board uses the same slot and spring terminals, and the TA5120-2AI-UI covers standard U\/I analog input instead. The 16-bit resolution gives finer temperature steps than the 12-bit TA5120-2AI-UI board.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54087231144219,"sku":"1SAP187100R0004","price":103.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sap187100r0004-ta5122-2ai-tc-plc-io-module.png?v=1791006051","url":"https:\/\/stoklink.com\/products\/abb-1sap187100r0004-ta5122-2ai-tc","provider":"Stoklink","version":"1.0","type":"link"}