{"product_id":"abb-1sam451000r1019-ms165-80-motor-protection-circuit-breaker","title":"ABB 1SAM451000R1019 MS165-80 Manual Motor Starter 70-80A 3P 45kW Motor Protection Circuit-Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eABB MS165-80 motor protection circuit-breaker\u003c\/strong\u003e (SKU: 1SAM451000R1019) is a 3-pole manual motor starter rated for 70–80 A continuous current, delivering robust overload and short-circuit protection for motors up to 45 kW in demanding industrial automation environments. The MS165-80 provides a breaking capacity of 30 kA at 230 V AC and fits into control panels with a compact 55 mm width, making it an efficient, space-saving solution for motor protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS165-80\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM451000R1019\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS165\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Protection Circuit-Breaker (Manual Motor Starter)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70…80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (230 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614536632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — North American safety certification for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for use in Canadian electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity — approved for Eurasian Economic Union markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e IEC Scheme for Explosive Atmospheres — certified for use in potentially explosive environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e ATmosphères EXplosibles — EU directive compliance for explosive atmosphere equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — mandatory safety mark for the South Korean market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit-breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electronic and electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European harmonised standard — circuit-breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard — contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-93:\u003c\/strong\u003e Supplementary standard for recovery and energy assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU directive on hazardous materials in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment — registered for compliant end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe ABB MS165-80 is engineered for motor protection in industrial automation and control panel applications where reliable, direct-on-line motor starting and protection is essential. Typical use cases include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of three-phase AC motors up to 45 kW in manufacturing and processing plants\u003c\/li\u003e\n  \u003cli\u003eMotor branch circuit protection in control panels and motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eApplications in potentially explosive atmospheres (ATEX\/IECEx certified)\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty pump, compressor, conveyor, and fan motor protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems requiring compact, reliable motor overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the rated current range of the MS165-80?\u003c\/strong\u003e The MS165-80 is adjustable from 70 A to 80 A, allowing fine-tuned motor protection within this range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the breaking capacity of the MS165-80?\u003c\/strong\u003e It provides a breaking capacity of 30 kA at 230 V AC, ensuring reliable fault clearance in high-fault-level installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs the MS165-80 suitable for explosive atmospheres?\u003c\/strong\u003e Yes — the MS165-80 carries both ATEX and IECEx certifications, making it suitable for use in hazardous and potentially explosive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the catalog number for this product?\u003c\/strong\u003e The customer-facing catalog number is \u003cstrong\u003eMS165-80\u003c\/strong\u003e; the internal SKU reference is 1SAM451000R1019.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229165850907,"sku":"1SAM451000R1019","price":160.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam451000r1019-ms165-80-motor-protection-circuit-breaker_60486c54-b2f3-4240-941d-f35609abdb5c.webp?v=1777156309","url":"https:\/\/stoklink.com\/products\/abb-1sam451000r1019-ms165-80-motor-protection-circuit-breaker","provider":"Stoklink","version":"1.0","type":"link"}