{"product_id":"schneider-electric-a9n61533-acti9-c60h-dc-2p-25a-dc-mcb","title":"Schneider Electric A9N61533 Acti9 C60H-DC 2P 25A C Curve DC Miniature Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric A9N61533 is a 2-pole, 25 A, C-curve DC miniature circuit breaker from the Acti9 C60H-DC range, rated for 500 V DC operational voltage. Its thermal-magnetic trip unit covers overload and short-circuit protection, it is suitable for isolation to IEC\/EN 60947-2, and it breaks 20 kA at 220-250 V DC or 6 kA at 500 V DC in a 36 mm DIN-rail body.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA9N61533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActi9 C60H-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P (2 protected poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu] (IEC\/EN 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA at 220 V DC · 20 kA at 250 V DC · 10 kA at 440 V DC · 6 kA at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 % of Icu: 15 kA at 220\/250 V DC · 7.5 kA at 440 V DC · 4.5 kA at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × 9 mm pitches (36 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComb Busbar Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop or bottom, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 N·m, power circuit top or bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlockable in O position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle, ON\/OFF contact position indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 in enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree \/ Overvoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 \/ IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.256 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN 60947-2\u003c\/li\u003e\n\u003cli\u003eGB 14048.2\u003c\/li\u003e\n\u003cli\u003eEU RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe A9N61533 carries its 25 A rating at a 25 °C reference, so in a sealed DC enclosure running warmer than that the usable continuous current falls; when the steady load already sits close to 25 A, the 32 A variant of the same C60H-DC frame is the safer pick. Breaking capacity depends on how high the DC bus voltage is: 20 kA Icu at 220-250 V DC, but only 10 kA at 440 V DC and 6 kA at 500 V DC, so check the prospective fault current of the battery bank or rectifier against the voltage you actually run before specifying it. With two protected poles, the positive and negative conductors are both opened and isolated, which suits floating or unearthed DC systems where either conductor can carry fault current. The C curve tolerates the moderate switch-on current of DC power supplies and small DC motors without nuisance tripping, while a B-curve breaker is the closer match for long cable runs with low fault levels.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230111240475,"sku":"A9N61533","price":217.47,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-a9n61533-c60h-dc-dc-miniature-circuit-breaker.jpg?v=1794834248","url":"https:\/\/stoklink.com\/en-sa\/products\/schneider-electric-a9n61533-acti9-c60h-dc-2p-25a-dc-mcb","provider":"Stoklink","version":"1.0","type":"link"}