{"product_id":"abb-1sca120096r1001-otm40f3cma230v","title":"ABB 1SCA120096R1001 OTM40F3CMA230V 3P 2.5 kA Icw Motorized Changeover Switch","description":"\u003cp\u003eThe ABB 1SCA120096R1001 is an OTM40F3CMA230V motorized changeover switch rated 40 A at 3 poles, driven by a 110-240 V AC\/DC motor to move a load between two sources. It carries a 2.5 kA short-time withstand for 1 s and an 800 V insulation rating. Like other CMA-suffix units, it has no built-in control logic, so automatic switching requires a separate controller.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA120096R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotorized Change-over Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOTM40F3CMA230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019516851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage, Main Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V (rated insulation class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current AC-21A (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current AC-23A (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A (380-690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Power AC-23A (Pe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW (380-415 V) \/ 22 kW (500 V) \/ 37 kW (690 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Free-air Thermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Thermal Current, Fully Enclosed (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 x 100 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 40 A the 1SCA120096R1001 is the smallest motorized changeover switch in this batch, sized for a distribution board rather than a main incomer, and its 2.5-16 mm2 terminal range matches that scale of cabling. Like the 125 A CMA unit, it has no onboard controller, so a separate ATS control module handles the automatic source-selection logic; the motor itself only executes the switching command. Where a self-contained 40 A, 3-pole device is preferred instead, ABB's Compact ATS variant with the 20D or 21D controller is the single-box alternative.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229278605595,"sku":"1SCA120096R1001","price":1401.54,"currency_code":"SAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca120096r1001-otm40f3cma230v-motorized-changeover-switch.gif?v=1790957380","url":"https:\/\/stoklink.com\/en-sa\/products\/abb-1sca120096r1001-otm40f3cma230v","provider":"Stoklink","version":"1.0","type":"link"}