{"title":"Siemens SENTRON 3VA MCCBs","description":"\u003cp\u003eSiemens SENTRON 3VA MCCBs are molded case circuit breakers for 16 A to 1250 A distribution and industrial circuits. The range covers 3-pole and 4-pole breakers in 3VA1 and 3VA2 versions, with nearly 300 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e3VA1 breakers with TM thermal-magnetic trip units.\u003c\/li\u003e\n\u003cli\u003e3VA2 breakers with ETU electronic trip units, including LSI.\u003c\/li\u003e\n\u003cli\u003eBreaking capacities from 36 kA up to 70 kA at 415 V in the listed parts.\u003c\/li\u003e\n\u003cli\u003eCompact option: \u003ca href=\"\/en-sa\/collections\/siemens-sentron-3vm\"\u003eSiemens SENTRON 3VM MCCBs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFrame size and rated current must cover the load.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity at 415 V must exceed the fault level.\u003c\/li\u003e\n\u003cli\u003ePick TM units for simple feeders and ETU units where selectivity or measurement is needed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between 3VA1 and 3VA2?\u003c\/h3\u003e\u003cp\u003e3VA1 uses thermal-magnetic trip units, while 3VA2 has electronic trip units with adjustable protection.\u003c\/p\u003e\u003ch3\u003eHow do I read a number like 3VA1112-6EF46-0AA0?\u003c\/h3\u003e\u003cp\u003e3VA1 is the family, and the rest encodes frame, rating, breaking capacity and poles. The title lists the values.\u003c\/p\u003e\u003ch3\u003eCan you ship 3VA breakers worldwide?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"siemens-3va1110-5mh36-0aa0-3va1-100a-55ka-3p-mccb","title":"Siemens 3VA1110-5MH36-0AA0 3VA1 100A 55kA 3-Pole Magnetic Protection Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5MH36-0AA0 is a 3-pole molded case circuit breaker from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA at 415 V AC. It provides magnetic-only protection, making it suited for motor branch circuits and starter protection applications where thermal overload is handled separately downstream.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5MH36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON 3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @ 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic only\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 × 92 × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.006 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eMagnetic-only protection in the 3VA1110-5MH36-0AA0 means the trip characteristic responds exclusively to instantaneous overcurrents — short circuits and severe fault currents — without a thermal element for sustained overload. This is the correct configuration when a separate motor overload relay or soft starter handles the thermal protection curve, keeping the MCCB focused on fault clearing at its 55 kA breaking capacity.\u003c\/p\u003e\n\u003cp\u003eAt 150 × 92 × 116 mm and 1.006 kg, the 3VA1 frame fits standard IEC switchboard busbar pitches without requiring extended depth. Three-pole configuration covers standard three-phase 415 V distribution and motor feeder circuits up to 100 A frame size.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52214665085211,"sku":"3VA1110-5MH36-0AA0","price":207.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/3va1110-5mh36-0aa0_d0f3c922-354d-4532-8ef7-d85e8ed01bc0.webp?v=1782491561"},{"product_id":"siemens-3va1225-4ef32-0aa0-sentron-3va12-250a-36ka-mccb","title":"Siemens 3VA1225-4EF32-0AA0 SENTRON 3VA12 250A 36kA 3P Thermal Magnetic Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1225-4EF32-0AA0 is a SENTRON 3VA12 series molded case circuit breaker rated 250 A at 415 V AC with a 36 kA breaking capacity at 380\/415 V. The 3-pole frame features independently adjustable thermal and magnetic trip settings across the 175–250 A range, making it suitable for feeder and motor branch circuit protection in industrial distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Model Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1225-4EF32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON 3VA12\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Thermal Trip Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175–250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 380\/415 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-magnetic, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar connection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 × 125 × 123 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.579 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 3VA1225-4EF32-0AA0 is configured for busbar-mounted installation in low-voltage switchgear panels and distribution boards. Its 36 kA breaking capacity at 415 V covers high fault-current environments typical of transformer secondaries up to ~630 kVA at standard impedance. The adjustable thermal-magnetic trip unit lets engineers dial in overload protection from 175 A to 250 A without changing the frame, reducing panel redesign time when load profiles shift. Three-pole construction handles three-phase distribution without a neutral pole, appropriate where neutral is bonded at the transformer.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52404988215579,"sku":"3VA1225-4EF32-0AA0","price":313.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/3va1225-4ef32-0aa0_34e66cde-ff14-46ba-a761-ecbaf9d1a412.webp?v=1782491119"},{"product_id":"siemens-3va1116-4ee36-0aa0-sentron-3va11-160a-36ka-3p-mccb","title":"Siemens 3VA1116-4EE36-0AA0 SENTRON 3VA11 160A 36kA 3-Pole Thermal Magnetic Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-4EE36-0AA0 is a SENTRON 3VA11 series 3-pole molded case circuit breaker rated at 160 A with a 36 kA breaking capacity at 400 V AC. It uses a thermal-magnetic trip unit with adjustable thermal overload and fixed magnetic short-circuit protection, covering the 112–160 A adjustment range in a compact frame suitable for distribution and feeder applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-4EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON 3VA11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu) @ 400 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-magnetic (adjustable thermal, fixed magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52405078524187,"sku":"3VA1116-4EE36-0AA0","price":212.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/3va1116-4ee36-0aa0_527826e8-e2c4-4776-bc29-d95618bd42c8.webp?v=1782491105"},{"product_id":"siemens-3va1110-4ee36-0aa0-3va1-3p-100a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-4EE36-0AA0 3VA1 3P 100A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-4EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-4EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.028 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VA1110-4EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619675435291,"sku":"3VA1110-4EE36-0AA0","price":154.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-4ee36-0aa0.webp?v=1784357429"},{"product_id":"siemens-3va1110-4ee46-0aa0-3va1-4p-100a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-4EE46-0AA0 3VA1 4P 100A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-4EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-4EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.297 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VA1110-4EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619682775323,"sku":"3VA1110-4EE46-0AA0","price":223.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/G_I202_XX_24632I.jpg?v=1784448066"},{"product_id":"siemens-3va1110-4ef36-0aa0-3va1-3p-100a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-4EF36-0AA0 3VA1 3P 100A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-4EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.026 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VA1110-4EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619682873627,"sku":"3VA1110-4EF36-0AA0","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-4ef36-0aa0.webp?v=1784358326"},{"product_id":"siemens-3va1110-4ef46-0aa0-3va1-4p-100a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-4EF46-0AA0 3VA1 4P 100A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-4EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-4EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VA1110-4EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619682906395,"sku":"3VA1110-4EF46-0AA0","price":229.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-4ef46-0aa0.webp?v=1784358334"},{"product_id":"siemens-3va1110-5ee36-0aa0-3va1-3p-100a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-5EE36-0AA0 3VA1 3P 100A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.981 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 55 kA breaking capacity, the 3VA1110-5EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619682971931,"sku":"3VA1110-5EE36-0AA0","price":181.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-5ee36-0aa0.webp?v=1784358341"},{"product_id":"siemens-3va1110-5ee46-0aa0-3va1-4p-100a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-5EE46-0AA0 3VA1 4P 100A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 55 kA breaking capacity, the 3VA1110-5EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683004699,"sku":"3VA1110-5EE46-0AA0","price":314.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-5ee46-0aa0.webp?v=1784358348"},{"product_id":"siemens-3va1110-5ef36-0aa0-3va1-3p-100a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-5EF36-0AA0 3VA1 3P 100A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.982 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 55 kA breaking capacity, the 3VA1110-5EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683037467,"sku":"3VA1110-5EF36-0AA0","price":189.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-5ef36-0aa0.webp?v=1784358355"},{"product_id":"siemens-3va1110-5ef46-0aa0-3va1-4p-100a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-5EF46-0AA0 3VA1 4P 100A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-5EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-5EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.266 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 55 kA breaking capacity, the 3VA1110-5EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683103003,"sku":"3VA1110-5EF46-0AA0","price":329.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-5ef46-0aa0.webp?v=1784358363"},{"product_id":"siemens-3va1110-6ef36-0aa0-3va1-3p-100a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-6EF36-0AA0 3VA1 3P 100A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-6EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-6EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.983 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 70 kA breaking capacity, the 3VA1110-6EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683135771,"sku":"3VA1110-6EF36-0AA0","price":271.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-6ef36-0aa0.webp?v=1784358370"},{"product_id":"siemens-3va1110-6ef46-0aa0-3va1-4p-100a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1110-6EF46-0AA0 3VA1 4P 100A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-6EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-6EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 70 kA breaking capacity, the 3VA1110-6EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683168539,"sku":"3VA1110-6EF46-0AA0","price":385.07,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-6ef46-0aa0.webp?v=1784358378"},{"product_id":"siemens-3va1110-6mh36-0aa0-3va1-3p-100a-70ka-415v-tm120m-i-molded-case-circuit-breaker","title":"Siemens 3VA1110-6MH36-0AA0 3VA1 3P 100A 70kA 415V TM120M I Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1110-6MH36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 100 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM120M I thermal-magnetic trip unit providing overload and short-circuit protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1110-6MH36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM120M — I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.964 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 70 kA breaking capacity, the 3VA1110-6MH36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM120M I trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683201307,"sku":"3VA1110-6MH36-0AA0","price":296.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1110-6mh36-0aa0.webp?v=1784358386"},{"product_id":"siemens-3va1112-4ee36-0aa0-3va1-3p-125a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-4EE36-0AA0 3VA1 3P 125A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-4EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-4EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.022 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VA1112-4EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683234075,"sku":"3VA1112-4EE36-0AA0","price":200.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-4ee36-0aa0.webp?v=1784358393"},{"product_id":"siemens-3va1112-4ee46-0aa0-3va1-4p-125a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-4EE46-0AA0 3VA1 4P 125A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-4EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-4EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.346 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VA1112-4EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683266843,"sku":"3VA1112-4EE46-0AA0","price":357.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-4ee46-0aa0.webp?v=1784358400"},{"product_id":"siemens-3va1112-4ef36-0aa0-3va1-3p-125a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-4EF36-0AA0 3VA1 3P 125A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-4EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.026 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VA1112-4EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683299611,"sku":"3VA1112-4EF36-0AA0","price":208.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-4ef36-0aa0.webp?v=1784358407"},{"product_id":"siemens-3va1112-4ef46-0aa0-3va1-4p-125a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-4EF46-0AA0 3VA1 4P 125A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-4EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-4EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.347 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VA1112-4EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683332379,"sku":"3VA1112-4EF46-0AA0","price":368.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-4ef46-0aa0.webp?v=1784358414"},{"product_id":"siemens-3va1112-5ee36-0aa0-3va1-3p-125a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-5EE36-0AA0 3VA1 3P 125A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-5EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-5EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VA1112-5EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683430683,"sku":"3VA1112-5EE36-0AA0","price":248.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-5ee36-0aa0.webp?v=1784358423"},{"product_id":"siemens-3va1112-5ee46-0aa0-3va1-4p-125a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-5EE46-0AA0 3VA1 4P 125A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-5EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-5EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.343 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VA1112-5EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683463451,"sku":"3VA1112-5EE46-0AA0","price":450.67,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-5ee46-0aa0.webp?v=1784358429"},{"product_id":"siemens-3va1112-5ef36-0aa0-3va1-3p-125a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-5EF36-0AA0 3VA1 3P 125A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-5EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-5EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VA1112-5EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683496219,"sku":"3VA1112-5EF36-0AA0","price":260.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-5ef36-0aa0.webp?v=1784358436"},{"product_id":"siemens-3va1112-5ef46-0aa0-3va1-4p-125a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-5EF46-0AA0 3VA1 4P 125A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-5EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-5EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.349 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VA1112-5EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683528987,"sku":"3VA1112-5EF46-0AA0","price":471.09,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-5ef46-0aa0.webp?v=1784358447"},{"product_id":"siemens-3va1112-5mh36-0aa0-3va1-3p-125a-55ka-415v-tm120m-i-molded-case-circuit-breaker","title":"Siemens 3VA1112-5MH36-0AA0 3VA1 3P 125A 55kA 415V TM120M I Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-5MH36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM120M I thermal-magnetic trip unit providing overload and short-circuit protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-5MH36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM120M — I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.058 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VA1112-5MH36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM120M I trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683594523,"sku":"3VA1112-5MH36-0AA0","price":267.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-5mh36-0aa0.webp?v=1784358455"},{"product_id":"siemens-3va1112-6ef36-0aa0-3va1-3p-125a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-6EF36-0AA0 3VA1 3P 125A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-6EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-6EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.041 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 70 kA breaking capacity, the 3VA1112-6EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683660059,"sku":"3VA1112-6EF36-0AA0","price":325.66,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-6ef36-0aa0.webp?v=1784358462"},{"product_id":"siemens-3va1112-6ef46-0aa0-3va1-4p-125a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1112-6EF46-0AA0 3VA1 4P 125A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-6EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-6EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.343 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 70 kA breaking capacity, the 3VA1112-6EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683692827,"sku":"3VA1112-6EF46-0AA0","price":630.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-6ef46-0aa0.webp?v=1784358470"},{"product_id":"siemens-3va1112-6mh36-0aa0-3va1-3p-125a-70ka-415v-tm120m-i-molded-case-circuit-breaker","title":"Siemens 3VA1112-6MH36-0AA0 3VA1 3P 125A 70kA 415V TM120M I Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1112-6MH36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 125 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM120M I thermal-magnetic trip unit providing overload and short-circuit protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1112-6MH36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM120M — I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 70 kA breaking capacity, the 3VA1112-6MH36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM120M I trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683758363,"sku":"3VA1112-6MH36-0AA0","price":408.27,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1112-6mh36-0aa0.webp?v=1784358477"},{"product_id":"siemens-3va1116-4ee46-0aa0-3va1-4p-160a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-4EE46-0AA0 3VA1 4P 160A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-4EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-4EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.345 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 36 kA breaking capacity, the 3VA1116-4EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683791131,"sku":"3VA1116-4EE46-0AA0","price":407.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-4ee46-0aa0.webp?v=1784358485"},{"product_id":"siemens-3va1116-4ef36-0aa0-3va1-3p-160a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-4EF36-0AA0 3VA1 3P 160A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-4EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.029 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 36 kA breaking capacity, the 3VA1116-4EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683823899,"sku":"3VA1116-4EF36-0AA0","price":221.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-4ef36-0aa0.webp?v=1784358492"},{"product_id":"siemens-3va1116-4ef46-0aa0-3va1-4p-160a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-4EF46-0AA0 3VA1 4P 160A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-4EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-4EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.333 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 36 kA breaking capacity, the 3VA1116-4EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683856667,"sku":"3VA1116-4EF46-0AA0","price":419.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-4ef46-0aa0.webp?v=1784358499"},{"product_id":"siemens-3va1116-5ee36-0aa0-3va1-3p-160a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-5EE36-0AA0 3VA1 3P 160A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-5EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-5EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.039 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 55 kA breaking capacity, the 3VA1116-5EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683889435,"sku":"3VA1116-5EE36-0AA0","price":264.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-5ee36-0aa0.webp?v=1784358509"},{"product_id":"siemens-3va1116-5ee46-0aa0-3va1-4p-160a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-5EE46-0AA0 3VA1 4P 160A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-5EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-5EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.336 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 55 kA breaking capacity, the 3VA1116-5EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683922203,"sku":"3VA1116-5EE46-0AA0","price":419.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-5ee46-0aa0.webp?v=1784358515"},{"product_id":"siemens-3va1116-5ef36-0aa0-3va1-3p-160a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-5EF36-0AA0 3VA1 3P 160A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-5EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-5EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.042 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 55 kA breaking capacity, the 3VA1116-5EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683954971,"sku":"3VA1116-5EF36-0AA0","price":276.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-5ef36-0aa0.webp?v=1784358522"},{"product_id":"siemens-3va1116-5ef46-0aa0-3va1-4p-160a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-5EF46-0AA0 3VA1 4P 160A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-5EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-5EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.337 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 55 kA breaking capacity, the 3VA1116-5EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619683987739,"sku":"3VA1116-5EF46-0AA0","price":438.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-5ef46-0aa0.webp?v=1784358530"},{"product_id":"siemens-3va1116-6ef36-0aa0-3va1-3p-160a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-6EF36-0AA0 3VA1 3P 160A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-6EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-6EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.044 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 70 kA breaking capacity, the 3VA1116-6EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684020507,"sku":"3VA1116-6EF36-0AA0","price":423.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-6ef36-0aa0.webp?v=1784358538"},{"product_id":"siemens-3va1116-6ef46-0aa0-3va1-4p-160a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1116-6EF46-0AA0 3VA1 4P 160A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1116-6EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 160 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1116-6EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.341 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 70 kA breaking capacity, the 3VA1116-6EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684053275,"sku":"3VA1116-6EF46-0AA0","price":717.46,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1116-6ef46-0aa0.webp?v=1784358545"},{"product_id":"siemens-3va1120-4ee36-0aa0-3va1-3p-20a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-4EE36-0AA0 3VA1 3P 20A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-4EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-4EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.999 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VA1120-4EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684086043,"sku":"3VA1120-4EE36-0AA0","price":189.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-4ee36-0aa0.webp?v=1784358552"},{"product_id":"siemens-3va1120-4ee46-0aa0-3va1-4p-20a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-4EE46-0AA0 3VA1 4P 20A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-4EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-4EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VA1120-4EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684118811,"sku":"3VA1120-4EE46-0AA0","price":226.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-4ee46-0aa0.webp?v=1784358559"},{"product_id":"siemens-3va1120-4ef36-0aa0-3va1-3p-20a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-4EF36-0AA0 3VA1 3P 20A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-4EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.993 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VA1120-4EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684151579,"sku":"3VA1120-4EF36-0AA0","price":193.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-4ef36-0aa0.webp?v=1784358566"},{"product_id":"siemens-3va1120-4ef46-0aa0-3va1-4p-20a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-4EF46-0AA0 3VA1 4P 20A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-4EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-4EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.289 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VA1120-4EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684184347,"sku":"3VA1120-4EF46-0AA0","price":235.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-4ef46-0aa0.webp?v=1784358574"},{"product_id":"siemens-3va1120-5ee36-0aa0-3va1-3p-20a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-5EE36-0AA0 3VA1 3P 20A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-5EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-5EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 55 kA breaking capacity, the 3VA1120-5EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684217115,"sku":"3VA1120-5EE36-0AA0","price":221.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-5ee36-0aa0.webp?v=1784358584"},{"product_id":"siemens-3va1120-5ee46-0aa0-3va1-4p-20a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-5EE46-0AA0 3VA1 4P 20A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-5EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-5EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.299 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 55 kA breaking capacity, the 3VA1120-5EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684282651,"sku":"3VA1120-5EE46-0AA0","price":254.78,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-5ee46-0aa0.webp?v=1784358590"},{"product_id":"siemens-3va1120-5ef36-0aa0-3va1-3p-20a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-5EF36-0AA0 3VA1 3P 20A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-5EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-5EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.032 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 55 kA breaking capacity, the 3VA1120-5EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684348187,"sku":"3VA1120-5EF36-0AA0","price":231.77,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-5ef36-0aa0.webp?v=1784358601"},{"product_id":"siemens-3va1120-5ef46-0aa0-3va1-4p-20a-55ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-5EF46-0AA0 3VA1 4P 20A 55kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-5EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-5EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.279 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 55 kA breaking capacity, the 3VA1120-5EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684380955,"sku":"3VA1120-5EF46-0AA0","price":266.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-5ef46-0aa0.webp?v=1784358609"},{"product_id":"siemens-3va1120-6ef36-0aa0-3va1-3p-20a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-6EF36-0AA0 3VA1 3P 20A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-6EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-6EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.022 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 70 kA breaking capacity, the 3VA1120-6EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684413723,"sku":"3VA1120-6EF36-0AA0","price":271.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-6ef36-0aa0.webp?v=1784358616"},{"product_id":"siemens-3va1120-6ef46-0aa0-3va1-4p-20a-70ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1120-6EF46-0AA0 3VA1 4P 20A 70kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1120-6EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 20 A with a breaking capacity of 70 kA (Icu) at 415 V AC (utilisation class H). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1120-6EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kA @415V AC (Icu, class H)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 70 kA breaking capacity, the 3VA1120-6EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684446491,"sku":"3VA1120-6EF46-0AA0","price":312.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1120-6ef46-0aa0.webp?v=1784358624"},{"product_id":"siemens-3va1125-4ee36-0aa0-3va1-3p-25a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1125-4EE36-0AA0 3VA1 3P 25A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1125-4EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1125-4EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.993 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VA1125-4EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684610331,"sku":"3VA1125-4EE36-0AA0","price":154.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1125-4ee36-0aa0.webp?v=1784358632"},{"product_id":"siemens-3va1125-4ee46-0aa0-3va1-4p-25a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1125-4EE46-0AA0 3VA1 4P 25A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1125-4EE46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1125-4EE46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.305 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VA1125-4EE46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684643099,"sku":"3VA1125-4EE46-0AA0","price":226.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1125-4ee46-0aa0.webp?v=1784358639"},{"product_id":"siemens-3va1125-4ef36-0aa0-3va1-3p-25a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1125-4EF36-0AA0 3VA1 3P 25A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1125-4EF36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1125-4EF36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.002 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VA1125-4EF36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684938011,"sku":"3VA1125-4EF36-0AA0","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1125-4ef36-0aa0.webp?v=1784358646"},{"product_id":"siemens-3va1125-4ef46-0aa0-3va1-4p-25a-36ka-415v-tm240-li-molded-case-circuit-breaker","title":"Siemens 3VA1125-4EF46-0AA0 3VA1 4P 25A 36kA 415V TM240 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1125-4EF46-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM240 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1125-4EF46-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM240 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VA1125-4EF46-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM240 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619684970779,"sku":"3VA1125-4EF46-0AA0","price":235.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1125-4ef46-0aa0.webp?v=1784358653"},{"product_id":"siemens-3va1125-5ee36-0aa0-3va1-3p-25a-55ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VA1125-5EE36-0AA0 3VA1 3P 25A 55kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VA1125-5EE36-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VA1 series, rated 25 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 690 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1125-5EE36-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC Frame 160\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.064 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 55 kA breaking capacity, the 3VA1125-5EE36-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame 160 enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619685003547,"sku":"3VA1125-5EE36-0AA0","price":181.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3va1125-5ee36-0aa0.webp?v=1784358660"}],"url":"https:\/\/stoklink.com\/en-sa\/collections\/siemens-sentron-3va.oembed","provider":"Stoklink","version":"1.0","type":"link"}