{"title":"Harting","description":null,"products":[{"product_id":"harting-19200031440-han-a-hood-3a-m20","title":"Harting 19200031440 Han A Single-Lever Hood 3A Top Entry M20 Heavy Duty Connector Hood","description":"\u003cp\u003eThe Harting 19200031440 is a Han A hood in size 3 A, with a single locking lever and one top-entry M20 cable gland. The zinc die-cast shell is powder-coated RAL 7037 and rated IP44 as supplied, reaching IP65\/IP67 once the separate seal screw is fitted, for service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19200031440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number (formatted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 20 003 1440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140124585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x M20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeal screw ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 | IP65 with seal screw | IP67 with seal screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZinc die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.4 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean customs tariff number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs supplied this hood is only IP44 - order the seal screw separately if the installation needs the IP65\/IP67 rating, since it is not bundled with the hood. Top entry suits panels where the cable has to drop straight down into the gland rather than approach from the side, which is the main layout difference against the Han B hoods in this size range. Zinc die-cast construction is specific to the Han A series; it is lighter than the aluminium die-cast used on Han B but has the same -40 to +125 °C rating.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090347872539,"sku":"19200031440","price":4.19,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19200031440-han-a-hood-3a-m20.jpg?v=1791033527"},{"product_id":"harting-19200031750-han-a-hood-coupler-3a-m20","title":"Harting 19200031750 Han A Single-Lever Hood Coupler 3A Top Entry M20 Heavy Duty Connector Hood","description":"\u003cp\u003eThe Harting 19200031750 is a Han A hood coupler, a cable-to-cable housing in size 3 A, with a single locking lever and one top-entry M20 cable gland. The zinc die-cast shell is powder-coated RAL 7037 and rated IP44 as supplied, reaching IP65\/IP67 once the separate seal screw is fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19200031750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number (formatted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 20 003 1750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140124639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable to cable housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x M20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeal screw ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 | IP65 with seal screw | IP67 with seal screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZinc die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (locking)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel, zinc plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eA cable-to-cable housing couples two cable ends directly rather than mounting one side to a panel, which is what separates this part from the standard 3 A hood also offered in Han A. It still needs the same seal screw, ordered separately, to move past the as-supplied IP44 rating up to IP65\/IP67. The locking lever here is steel rather than the polycarbonate-and-stainless combination used on larger Han B hoods, matched to the smaller 3 A frame's lower mating force.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090348462363,"sku":"19200031750","price":6.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19200031750-han-a-hood-coupler-3a-m20.jpg?v=1791033540"},{"product_id":"harting-19300100272-han-b-surface-base-10b-m32","title":"Harting 19300100272 Han B Double-Lever Surface Base 10B HC 2x M32 Heavy Duty Connector Housing","description":"\u003cp\u003eThe Harting 19300100272 is a Han B surface mounted housing in size 10 B, high construction, with a double Han-Easy Lock locking lever. Two M32 side entries bring cables in, and the aluminium die-cast body is sealed to IP65 with an NBR gasket, rated for continuous service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19300100272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140125308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHan-Easy Lock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x M32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 | 4X | 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMating cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminium die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (locking)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC) | Stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (seal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 182.3\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe double lever on this 10 B base matches the double-lever 10 B hoods in the line - check lever count before pairing, since a single-lever hood will not latch onto this base. Two M32 entries suit metric gland stock already used elsewhere on the panel; choose the Pg 29 sibling base instead where the cable assembly already terminates in Pg thread. Han-Easy Lock keeps mating repeatable without tooling, which matters on a base handling many connect\/disconnect cycles.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090349019419,"sku":"19300100272","price":22.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19300100272-han-b-surface-base-10b-m32.jpg?v=1791033551"},{"product_id":"harting-19300240282-han-b-surface-base-24b-m32","title":"Harting 19300240282 Han B Central-Lever Surface Base 24B HC 2x M32 IP65 Heavy Duty Connector Housing","description":"\u003cp\u003eThe Harting 19300240282 is a Han B surface mounted housing in size 24 B, rated IP65 and built in high construction for pairing with a central-locking-lever hood. Two M32 cable entries come in from the side face, and the aluminium die-cast body with an NBR seal is rated for continuous service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19300240282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140126633\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral locking lever (on the hood)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x M32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 | 4X | 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMating cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminium die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (seal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e426 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean customs tariff number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis base takes a size 24 B Han B insert frame and pairs only with a matching central-locking-lever hood - a double-lever hood will not latch onto this base, so lever type has to match across the two halves. The two M32 side entries route both cables out from the same face, which helps in panel layouts where entry depth above the connector is tight. IP65 covers washdown-adjacent panel mounting; the double-lever PG-entry hood in the same frame size reaches IP66\/IP67 when fully sealed cable glands are needed instead of M32 fittings.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090349773083,"sku":"19300240282","price":36.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19300240282-han-b-surface-base-24b.jpg?v=1791033562"},{"product_id":"harting-24020050010-havis-econ-2050b-a-5-port-switch","title":"Harting 24020050010 Ha-VIS eCon 2000 2050B-A 5-Port Unmanaged Industrial Ethernet Switch","description":"\u003cp\u003eThe Harting 24020050010 Ha-VIS eCon 2050B-A is an unmanaged 5-port Fast Ethernet switch for DIN-rail mounting, built for 24 V DC or 48 V DC supply (permissible range 9-60 V DC) and an IP30 housing. It switches on all 5 10\/100 Mbit\/s RJ45 ports using store-and-forward technology, and runs from 0 to +55 °C operating temperature, which covers a standard control cabinet without forced cooling.\u003c\/p\u003e\u003cp\u003eEach port auto-negotiates speed and duplex and auto-detects straight or crossover cabling (Auto-MDI(X)), so installers do not need to match cable types port by port. The switch is non-blocking across all 5 ports and supports basic quality-of-service handling and Energy Efficient Ethernet, but it has no management interface, no PoE output, and no redundancy protocol - it is a plug-and-forward device, not a configurable node on the network.\u003c\/p\u003e\u003cp\u003ePower connects through a 3-pin pluggable screw terminal (+, -, FE) rated for 0.08-2.5 mm² conductors (AWG 28-12), with reverse-polarity protection and a 2 A input overcurrent protection built in. At 24 V DC the switch draws under 42 mA in steady state (1.01 W); inrush current on power-up stays under 2.8 A. The aluminium housing is 46.5 mm wide on the DIN rail and is rated IP30 once mated, so it still needs an enclosure against dust and moisture ingress.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 02 005 0010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24020050010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHa-VIS eCon 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnmanaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal number of ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\/100 Mbit\/s RJ45 ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStore and Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMAC table size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1k Entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacket buffer size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44 Megabit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon blocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuality of service\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Efficient Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail acc. to EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC | 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 ... 60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;42 mA @ 24 V DC, \u0026lt;23 mA @ 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A at input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePluggable screw contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.08 ... 2.5 mm² (AWG 28 ... AWG 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eFCC\u003c\/li\u003e\n\u003cli\u003eEN 55022\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-2\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-3\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-4\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-5\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-6\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eIEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 5-port 2050B-A is the smallest body in the eCon 2000 family at 46.5 mm wide, sized for a cell-level switch serving a handful of drives or I\/O blocks on one machine rather than a cabinet backbone. Step up to the 2080B-A (8 ports) or 2160B-A (16 ports) when more end devices need to land on the same segment - all three share identical voltage range, port electronics, and mounting, so swapping sizes does not change the wiring or power design.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090350231835,"sku":"24020050010","price":148.54,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-24020050010-havis-econ-2050b-a-5-port-switch.jpg?v=1791033574"},{"product_id":"harting-24020160010-havis-econ-2160b-a-16-port-switch","title":"Harting 24020160010 Ha-VIS eCon 2000 2160B-A 16-Port Unmanaged Industrial Ethernet Switch","description":"\u003cp\u003eThe Harting 24020160010 Ha-VIS eCon 2160B-A is an unmanaged 16-port Fast Ethernet switch for DIN-rail mounting, built for 24 V DC or 48 V DC supply (permissible range 9-60 V DC) and an IP30 housing. It switches on all 16 10\/100 Mbit\/s RJ45 ports using store-and-forward technology, and runs from 0 to +55 °C operating temperature, which covers a standard control cabinet without forced cooling.\u003c\/p\u003e\u003cp\u003eEach port auto-negotiates speed and duplex and auto-detects straight or crossover cabling (Auto-MDI(X)), so installers do not need to match cable types port by port. The switch is non-blocking across all 16 ports and supports basic quality-of-service handling and Energy Efficient Ethernet, but it has no management interface, no PoE output, and no redundancy protocol - it is a plug-and-forward device, not a configurable node on the network.\u003c\/p\u003e\u003cp\u003ePower connects through a 3-pin pluggable screw terminal (+, -, FE) rated for 0.08-2.5 mm² conductors (AWG 28-12), with reverse-polarity protection and a 2 A input overcurrent protection built in. At 24 V DC the switch draws under 93 mA in steady state (2.23 W); inrush current on power-up stays under 1.6 A. The aluminium housing is 120 mm wide on the DIN rail and is rated IP30 once mated, so it still needs an enclosure against dust and moisture ingress.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 02 016 0010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24020160010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHa-VIS eCon 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnmanaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal number of ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\/100 Mbit\/s RJ45 ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStore and Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMAC table size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8k Entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacket buffer size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Megabit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon blocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuality of service\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Efficient Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail acc. to EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC | 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 ... 60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;93 mA @ 24 V DC, \u0026lt;49 mA @ 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A at input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePluggable screw contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.08 ... 2.5 mm² (AWG 28 ... AWG 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eFCC\u003c\/li\u003e\n\u003cli\u003eEN 55022\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-2\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-3\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-4\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-5\u003c\/li\u003e\n\u003cli\u003eEN 61000-4-6\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eIEC 60068-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 16-port 2160B-A is the largest body in the eCon 2000 family at 120 mm wide, with an 8k-entry MAC table and 2 Megabit packet buffer - both larger than the 5- and 8-port variants - sized for a cabinet-level switch aggregating multiple machine segments rather than a single cell. Pick the 2050B-A or 2080B-A instead when the port count needed is 5 or 8, since the smaller bodies save DIN-rail space for the same unmanaged feature set.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090350657819,"sku":"24020160010","price":403.67,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-24020160010-havis-econ-2160b-a-16-port-switch.jpg?v=1791033588"}],"url":"https:\/\/stoklink.com\/en-sa\/collections\/harting.oembed","provider":"Stoklink","version":"1.0","type":"link"}