{"title":"Cam Switches","description":"\u003cp\u003eCam switches from Schneider Electric in the Harmony K range, available in 1P to 4P versions with changeover, stepping and voltmeter functions. Stoklink lists over 15 items across the K1, K2, K30 and K63 sizes. We ship worldwide from Turkey and quote project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eK1 cam switches for 12 A control and small loads.\u003c\/li\u003e\n\u003cli\u003eK2 cam switches for 20 A duty.\u003c\/li\u003e\n\u003cli\u003eK30 and K63 sizes for higher current, up to the 63 A changeover type.\u003c\/li\u003e\n\u003cli\u003eChangeover, stepping and voltmeter selector versions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSize and rated current. K1, K2, K30 and K63 correspond to increasing ampere ratings.\u003c\/li\u003e\n\u003cli\u003eFunction. Choose on-off, changeover, stepping or voltmeter selector.\u003c\/li\u003e\n\u003cli\u003ePoles. Count the circuits to be switched.\u003c\/li\u003e\n\u003cli\u003eOperating angle. Versions with 45 or 60 degree steps change the handle positions.\u003c\/li\u003e\n\u003cli\u003eMounting. Front mount fits panel door cut-outs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat is a cam switch used for?\u003c\/h3\u003e\u003cp\u003eIt selects between circuits or positions with a rotary handle. Typical jobs are manual on-off, source selection, and voltmeter or ammeter phase selection.\u003c\/p\u003e\u003ch3\u003eCan a cam switch be used as a main isolator?\u003c\/h3\u003e\u003cp\u003eOnly if the datasheet declares isolation and the rating fits the load. Otherwise use a switch disconnector for isolation duty.\u003c\/p\u003e\u003ch3\u003eDo you ship outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-k1a001alh-harmony-k","title":"Schneider Electric K1A001ALH Harmony K","description":"\u003cp data-start=\"209\" data-end=\"460\"\u003eThe \u003cstrong data-start=\"213\" data-end=\"245\"\u003eSchneider Electric K1A001ALH\u003c\/strong\u003e is a precision 1-pole cam switch from the Harmony K family. Designed for robust industrial control, it offers reliable ON\/OFF switching, durable build quality, and compatibility with standard panel installations.\u003c\/p\u003e\n\u003chr data-start=\"462\" data-end=\"465\"\u003e\n\u003ch3 data-start=\"467\" data-end=\"494\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"496\" data-end=\"1962\"\u003e\n\u003cli data-start=\"496\" data-end=\"670\"\u003e\n\u003cp data-start=\"498\" data-end=\"670\"\u003e\u003cstrong data-start=\"498\" data-end=\"540\"\u003eSingle-Pole, Two-Position (0-1) Switch\u003c\/strong\u003e\u003cbr data-start=\"540\" data-end=\"543\"\u003eProvides two stable positions: “OFF (0)” and “ON (1)” for simple and intuitive control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"672\" data-end=\"853\"\u003e\n\u003cp data-start=\"674\" data-end=\"853\"\u003e\u003cstrong data-start=\"674\" data-end=\"714\"\u003e12 A Free-Air Thermal Current Rating\u003c\/strong\u003e\u003cbr data-start=\"714\" data-end=\"717\"\u003eRated conventional free-air thermal current of \u003cstrong data-start=\"766\" data-end=\"774\"\u003e12 A\u003c\/strong\u003e, sufficient for moderate load switching.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"855\" data-end=\"994\"\u003e\n\u003cp data-start=\"857\" data-end=\"994\"\u003e\u003cstrong data-start=\"857\" data-end=\"883\"\u003eSwitching Angle of 45°\u003c\/strong\u003e\u003cbr data-start=\"883\" data-end=\"886\"\u003eSmooth operation with a compact 45° rotary travel between positions.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"996\" data-end=\"1204\"\u003e\n\u003cp data-start=\"998\" data-end=\"1204\"\u003e\u003cstrong data-start=\"998\" data-end=\"1060\"\u003eMulti-Fixing, Front Mount Design with 45×45 mm Front Plate\u003c\/strong\u003e\u003cbr data-start=\"1060\" data-end=\"1063\"\u003eAllows for versatile mounting in panels; the 45 mm × 45 mm front plate helps streamline installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1400\"\u003e\n\u003cp data-start=\"1208\" data-end=\"1400\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1255\"\u003eBlack Handle with Clear 0-1 Metallic Legend\u003c\/strong\u003e\u003cbr data-start=\"1255\" data-end=\"1258\"\u003eThe rotary handle (≈ 35 mm) is black, with “0-1” printed clearly, aiding visual clarity for operators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1402\" data-end=\"1573\"\u003e\n\u003cp data-start=\"1404\" data-end=\"1573\"\u003e\u003cstrong data-start=\"1404\" data-end=\"1443\"\u003eHigh Insulation \u0026amp; Voltage Endurance\u003c\/strong\u003e\u003cbr data-start=\"1443\" data-end=\"1446\"\u003eRated insulation voltage up to \u003cstrong data-start=\"1479\" data-end=\"1488\"\u003e690 V\u003c\/strong\u003e, pollution degree 3 per IEC 60947-1 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1575\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1577\" data-end=\"1768\"\u003e\u003cstrong data-start=\"1577\" data-end=\"1591\"\u003eDurability\u003c\/strong\u003e\u003cbr data-start=\"1591\" data-end=\"1594\"\u003eMechanical life rated to \u003cstrong data-start=\"1621\" data-end=\"1643\"\u003e≈ 1,000,000 cycles\u003c\/strong\u003e under AC-15 usage; slow-break contacts help protect equipment and extend contact life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1770\" data-end=\"1962\"\u003e\n\u003cp data-start=\"1772\" data-end=\"1962\"\u003e\u003cstrong data-start=\"1772\" data-end=\"1793\"\u003eProtection Rating\u003c\/strong\u003e\u003cbr data-start=\"1793\" data-end=\"1796\"\u003eIP40 protection (front and body) suitable for indoor panel-mounted use where the switch is not exposed to water or heavy dust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1964\" data-end=\"1967\"\u003e\n\u003ch3 data-start=\"1969\" data-end=\"2007\"\u003eTechnical Specifications (Summary)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2009\" data-end=\"2532\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2009\" data-end=\"2034\"\u003e\n\u003ctr data-start=\"2009\" data-end=\"2034\"\u003e\n\u003cth data-start=\"2009\" data-end=\"2025\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2025\" data-end=\"2034\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2049\" data-end=\"2532\"\u003e\n\u003ctr data-start=\"2049\" data-end=\"2093\"\u003e\n\u003ctd data-start=\"2049\" data-end=\"2057\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2057\" data-end=\"2093\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"2059\" data-end=\"2072\"\u003eK1A001ALH\u003c\/strong\u003e (Harmony K Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2094\" data-end=\"2119\"\u003e\n\u003ctd data-start=\"2094\" data-end=\"2102\" data-col-size=\"sm\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-start=\"2102\" data-end=\"2119\" data-col-size=\"md\"\u003e1P (one pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2120\" data-end=\"2155\"\u003e\n\u003ctd data-start=\"2120\" data-end=\"2132\" data-col-size=\"sm\"\u003ePositions\u003c\/td\u003e\n\u003ctd data-start=\"2132\" data-end=\"2155\" data-col-size=\"md\"\u003e2 (0 = OFF, 1 = ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2156\" data-end=\"2181\"\u003e\n\u003ctd data-start=\"2156\" data-end=\"2174\" data-col-size=\"sm\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2174\" data-end=\"2181\"\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2182\" data-end=\"2223\"\u003e\n\u003ctd data-start=\"2182\" data-end=\"2204\" data-col-size=\"sm\"\u003eRated Current (Ith)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2204\" data-end=\"2223\"\u003e12 A (free-air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2224\" data-end=\"2254\"\u003e\n\u003ctd data-start=\"2224\" data-end=\"2245\" data-col-size=\"sm\"\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2245\" data-end=\"2254\" data-col-size=\"md\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2255\" data-end=\"2316\"\u003e\n\u003ctd data-start=\"2255\" data-end=\"2272\" data-col-size=\"sm\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-start=\"2272\" data-end=\"2316\" data-col-size=\"md\"\u003eFront-mount, multifixing, 45×45 mm plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2317\" data-end=\"2372\"\u003e\n\u003ctd data-start=\"2317\" data-end=\"2326\" data-col-size=\"sm\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-start=\"2326\" data-end=\"2372\" data-col-size=\"md\"\u003eBlack, 35 mm rotary, metallic legend “0-1”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2373\" data-end=\"2402\"\u003e\n\u003ctd data-start=\"2373\" data-end=\"2394\" data-col-size=\"sm\"\u003eProtection (Front)\u003c\/td\u003e\n\u003ctd data-start=\"2394\" data-end=\"2402\" data-col-size=\"md\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2403\" data-end=\"2450\"\u003e\n\u003ctd data-start=\"2403\" data-end=\"2421\" data-col-size=\"sm\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd data-start=\"2421\" data-end=\"2450\" data-col-size=\"md\"\u003e~1,000,000 cycles (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2451\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2463\" data-col-size=\"sm\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-start=\"2463\" data-end=\"2532\" data-col-size=\"md\"\u003eComplies with IEC\/EN 60947-1, IEC\/EN 60947-3, etc. as appropriate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2534\" data-end=\"2537\"\u003e\n\u003ch3 data-start=\"2539\" data-end=\"2563\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2565\" data-end=\"2893\"\u003e\n\u003cli data-start=\"2565\" data-end=\"2647\"\u003e\n\u003cp data-start=\"2567\" data-end=\"2647\"\u003eON\/OFF switching in control panels, motor control, or machinery power circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2648\" data-end=\"2741\"\u003e\n\u003cp data-start=\"2650\" data-end=\"2741\"\u003ePower switching in industrial automation setups where clear, labeled positions are needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2742\" data-end=\"2802\"\u003e\n\u003cp data-start=\"2744\" data-end=\"2802\"\u003eControl of lighting, small motors, or auxiliary circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2803\" data-end=\"2893\"\u003e\n\u003cp data-start=\"2805\" data-end=\"2893\"\u003eReplacement or upgrade of older selector cam switches in panels with standard cut-outs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230559834395,"sku":"K1A001ALH","price":19.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1a001alh-k1a001alh-harmony-k_aaa388b3-fffe-4b12-b18e-d1e2e12595aa.jpg?v=1777185518"},{"product_id":"schneider-electric-k1b001ulh-harmony-k-cam-switch","title":"Schneider Electric K1B001ULH Harmony K K1 1-Pole Changeover Cam Switch 12 A 45 Degree","description":"\u003cp\u003eThe Schneider Electric K1B001ULH is a Harmony K1 cam changeover switch with a single pole, an off position, and a 45-degree switching angle. Rated for 12 A conventional free-air thermal current (Ith) and 690 V insulation voltage, it mounts to a 45 x 45 mm front plate with multi-fixing and carries IP40 protection for panel-door control stations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1B001ULH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight: 0-45 deg | Left: 0-315 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free-Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional Enclosed Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V (pollution degree 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (isolating) \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current, AC-3 3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 A at 690 V | 2.8 A at 500 V | 3.3 A at 400 V | 4.6 A at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG cartridge fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront mounting, multi-fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm2 flexible \/ 1 x 2.5 mm2 solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K1B001ULH is the 1-pole changeover variant in the Harmony K1 cam-switch line, moving between two positions plus an off position across a 45-degree arc, unlike the 2-pole configuration used where two independent circuits need switching together. Its 12 A Ith rating and 690 V insulation voltage (pollution degree 3) size it for control-circuit switching rather than direct motor starting, and the 16 A gG fuse back-up sets the coordinated short-circuit protection. IP40 keeps it suited to enclosed panel fronts rather than washdown areas.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual selector or changeover element on control panel doors, for example switching between two control modes or supply sources, where the 45-degree throw and metallic 2-0-1 legend give operators clear position feedback. Multi-fixing front-plate mounting on a 45 x 45 mm cut-out fits standard pilot-device panel layouts alongside pushbuttons and pilot lights.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230559965467,"sku":"K1B001ULH","price":18.59,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1b001ulh-harmony-k-cam-switch.jpg?v=1790284042"},{"product_id":"schneider-electric-k1b002alh-harmony-k-cam-switch","title":"Schneider Electric K1B002ALH Harmony K K1 2-Pole Cam Switch 12 A 45 Degree","description":"\u003cp\u003eThe Schneider Electric K1B002ALH is a Harmony K1 cam switch with two poles, an off position, and a 45-degree switching angle. Rated for 12 A conventional free-air thermal current (Ith) and 690 V insulation voltage, it mounts to a 45 x 45 mm front plate with multi-fixing and carries IP40 protection for panel-door control stations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1B002ALH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight: 0-45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free-Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional Enclosed Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V (pollution degree 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (isolating) \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current, AC-3 3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 A at 690 V | 2.8 A at 500 V | 3.3 A at 400 V | 4.6 A at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG cartridge fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront mounting, multi-fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm2 flexible \/ 1 x 2.5 mm2 solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.113 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K1B002ALH is the 2-pole configuration in the Harmony K1 cam-switch line, switching two independent circuits together across a single 0-45-degree throw rather than the changeover (double-throw) action of the 1-pole variant. Its 12 A Ith rating and 690 V insulation voltage (pollution degree 3) size it for control-circuit switching, and the 16 A gG fuse back-up sets the coordinated short-circuit protection. CCC and GB\/T 14048.3 \/ 14048.5 certification alongside the IEC 60947 base standards extend its use to China-market panel builds. IP40 keeps it suited to enclosed panel fronts rather than washdown areas.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual on\/off selector on control panel doors, for two circuits switched together such as a two-speed selection or dual-supply isolation, where the 45-degree throw and 0-1 legend give operators clear position feedback. Multi-fixing front-plate mounting on a 45 x 45 mm cut-out fits standard pilot-device panel layouts alongside pushbuttons and pilot lights.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230560162075,"sku":"K1B002ALH","price":18.59,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1b002alh-harmony-k-cam-switch.jpg?v=1790284049"},{"product_id":"schneider-electric-k1b002qlh-cam-switch","title":"Schneider Electric K1B002QLH Harmony K K1 1-Pole 12A 45deg Cam Stepping Switch","description":"\u003cp\u003eThe Schneider Electric K1B002QLH is a Harmony K1 cam stepping switch with a single pole, a 45° switching angle, and a 12 A conventional free-air thermal current (Ith). It has two steps plus an off position, uses a black handle with a 0-1-2 metallic legend, and mounts to a front panel via multifixing for local two-step or two-source selection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1B002QLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStepping switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45° - 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 400V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 230V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K1B002QLH's 0-1-2 stepping function with an off position suits two-step selection or dual-source changeover panels where an operator needs a visible off state between steps. Its single-pole, 45° switching angle and 12 A Ith rating fit small control or signal circuits rather than direct motor switching — at 400 V AC-3 the rated operational current drops to 3.3 A, so size it for pilot or auxiliary circuits, not the main power feed. Multifixing mounting lets it drop into a standard 45 x 45 mm cutout alongside other Harmony K series switches on the same panel.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual selector or stepping switch on control-panel doors for two-speed selection, dual-source changeover, or sequence-step control in machine-building and panel-shop applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230560227611,"sku":"K1B002QLH","price":18.86,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1b002qlh-harmony-k1-cam-switch.jpg?v=1790287288"},{"product_id":"schneider-electric-k1c003alh-cam-switch","title":"Schneider Electric K1C003ALH Harmony K K1 3-Pole 12A 45deg Cam Switch","description":"\u003cp\u003eThe Schneider Electric K1C003ALH is a Harmony K1 cam switch with three poles, a 45° switching angle, and a 12 A conventional free-air thermal current (Ith). It switches between an off position and one on position (0-1 marking) via a black handle with metallic legend, and mounts to a front panel by multifixing for three-phase circuit on\/off control.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1C003ALH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 400V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 230V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K1C003ALH switches three poles simultaneously between off and one on position, making it a straightforward three-phase disconnect or selector rather than a stepping switch — pick a stepping variant in the K1 range instead if the application needs multiple on positions. Its 12 A Ith and 690 V Ui rating size it for pilot power or small three-phase loads on a control panel, not as the main motor disconnect. CCC and GB\/T 14048.3\/14048.5 certification on this variant supports use in installations that require Chinese national approval alongside the IEC\/CENELEC base standards.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual three-phase selector or disconnect switch on control-panel doors in machine-building and panel-shop assemblies where a compact 45 x 45 mm cam switch replaces a separate toggle or rotary disconnect.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230560948507,"sku":"K1C003ALH","price":21.01,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1c003alh-harmony-k1-cam-switch.jpg?v=1790287295"},{"product_id":"schneider-electric-k1c003nlh-cam-switch","title":"Schneider Electric K1C003NLH Harmony K K1 1-Pole 12A 3-Step Cam Stepping Switch","description":"\u003cp\u003eThe Schneider Electric K1C003NLH is a Harmony K1 cam stepping switch with a single pole, a 45° switching angle, and a 12 A conventional free-air thermal current (Ith). It has three steps (1-2-3 marking) with no off position, so the circuit stays live at every switch position, and it mounts to a front panel by multifixing for continuous three-position selection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1C003NLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStepping switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45° - 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 400V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) at 230V AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the off-position stepping switch in the K1 range, the K1C003NLH has no off position — the circuit is always connected to step 1, 2, or 3, so use it where a de-energized state is never required, such as selecting between three fixed setpoints that must always have one active. Its single pole and 12 A Ith rating suit pilot or signal circuits rather than direct motor power. The 0°-45°-90° switching range gives three distinct 45° detents for the three positions.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a three-position selector switch on control-panel doors for choosing between three fixed setpoints, ranges, or signal sources where the circuit must always remain connected to one of the positions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230561145115,"sku":"K1C003NLH","price":22.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1c003nlh-harmony-k1-cam-switch.jpg?v=1790287301"},{"product_id":"schneider-electric-k1c003qlh-cam-stepping-switch","title":"Schneider Electric K1C003QLH Harmony K K1 12A 1P 3-Step Cam Stepping Switch","description":"\u003cp\u003eThe Schneider Electric K1C003QLH is a Harmony K1 cam stepping switch with a single pole, three switching steps at 45-degree increments, and a 12 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate and screw-clamp terminals, it switches AC-21 loads up to 8.3 kW at 400 V within an IP40 enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1C003QLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStepping switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg - 45 deg - 90 deg - 135 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1-pole, 3-step configuration suits simple sequential control, selecting between three positions in 45-degree increments off a single pole, such as switching a single-phase load between two speeds or supply sources plus an off position. Choose the 4-step variant of the same K1 stepping switch when a fourth position is needed, or a K1 changeover version when only two directions without intermediate steps are required. The 690 V insulation rating and 10 kA short-circuit withstand behind a 16 A gG fuse suit control-panel front-plate mounting ahead of contactor-controlled motor circuits rather than direct motor switching at full load.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230561276187,"sku":"K1C003QLH","price":22.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1c003qlh-k1-cam-stepping-switch.jpg?v=1790284914"},{"product_id":"schneider-electric-k1d002ulh-cam-changeover-switch","title":"Schneider Electric K1D002ULH Harmony K K1 12A 2P 45° Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K1D002ULH is a Harmony K1 cam changeover switch with two poles, a 45-degree switching angle, and a 12 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate, screw-clamp terminals, and a metallic 2-0-1 legend, it handles AC-3 motor loads up to 1.5 kW at 400 V within an IP40 enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1D002ULH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft: 0 deg - 315 deg | Right: 0 deg - 45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2-pole changeover configuration switches a single-phase circuit between two sources or directions through a 45-degree throw, using the metallic 2-0-1 legend to mark both positions plus off. Choose the 3-pole or 4-pole K2 changeover switches when the circuit is three-phase; this K1 body is sized for the lighter 12 A Ith \/ 10 A Ithe duty rather than direct three-phase motor reversing at full load. The 10 kA short-circuit withstand behind a 16 A gG fuse sets the upstream fuse protection needed ahead of the switch.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230561538331,"sku":"K1D002ULH","price":25.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1d002ulh-k1-cam-changeover-switch.jpg?v=1790284922"},{"product_id":"schneider-electric-k1d004qlh-cam-stepping-switch","title":"Schneider Electric K1D004QLH Harmony K K1 12A 1P 4-Step Cam Stepping Switch","description":"\u003cp\u003eThe Schneider Electric K1D004QLH is a Harmony K1 cam stepping switch with a single pole, four switching steps spanning 0 to 180 degrees at 45-degree increments, and a 12 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate and screw-clamp terminals, it switches AC-21 loads up to 8.3 kW at 400 V within an IP40 enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1D004QLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStepping switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg - 45 deg - 90 deg - 135 deg - 180 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4-step configuration adds a fourth 45-degree position over the 3-step K1 stepping switch, giving an extra selectable position for control or indicator-lamp circuit switching from a single pole. Use the 3-step version when only three positions are needed; both share the same 45 x 45 mm plate and 12 A Ith rating. The 690 V insulation rating and 16 A gG fuse back-up match the K1 body's 10 kA short-circuit withstand.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230562193691,"sku":"K1D004QLH","price":26.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1d004qlh-k1-cam-stepping-switch.jpg?v=1790284928"},{"product_id":"schneider-electric-k1d024mlh-cam-switch","title":"Schneider Electric K1D024MLH Harmony K K1 3-Phase 12A Cam Voltmeter Switch","description":"\u003cp\u003eThe Schneider Electric K1D024MLH is a Harmony K1 cam voltmeter switch that selects between three line-to-line voltage pairs (L1L2, L2L3, L3L1) plus an off position, with a 12 A conventional free-air thermal current (Ith) and 690 V rated insulation voltage. Its black handle carries a 0-L1L2-L2L3-L3L1 metallic legend across four 45° switching positions for connecting a single voltmeter to any of the three phase pairs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1D024MLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK1 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltmeter switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween 3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45° - 90° - 135°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K1D024MLH is a voltmeter selector, not a load switch — it lets one panel-mounted voltmeter read any of the three line-to-line pairs by rotating through four positions instead of wiring three separate meters. Its off position isolates the voltmeter circuit when the panel is not being monitored. Size it for a voltmeter's instrumentation-level burden, not for motor or power switching, since no AC-3 operational current rating applies to this voltmeter-switch function.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed on switchboard and panel-builder projects that need a single voltmeter to display all three line-to-line voltages via a front-panel selector instead of a dedicated meter per phase pair.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230562881819,"sku":"K1D024MLH","price":26.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1d024mlh-harmony-k1-cam-switch.jpg?v=1790287308"},{"product_id":"schneider-electric-k1f003mlh-harmony-k","title":"Schneider Electric K1F003MLH Harmony K","description":"\u003cp data-start=\"227\" data-end=\"539\"\u003eUse the \u003cstrong data-start=\"235\" data-end=\"267\"\u003eSchneider Electric K1F003MLH\u003c\/strong\u003e to monitor currents across three circuits safely and reliably. Part of the Harmony K line, this cam ammeter switch offers precise measurements, solid construction, and standard industrial protection—designed for electrical panels and industrial automation applications.\u003c\/p\u003e\n\u003chr data-start=\"541\" data-end=\"544\"\u003e\n\u003ch3 data-start=\"546\" data-end=\"573\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"575\" data-end=\"1828\"\u003e\n\u003cli data-start=\"575\" data-end=\"815\"\u003e\n\u003cp data-start=\"577\" data-end=\"815\"\u003e\u003cstrong data-start=\"577\" data-end=\"616\"\u003eThree-Circuit Ammeter Functionality\u003c\/strong\u003e\u003cbr data-start=\"616\" data-end=\"619\"\u003eAllows switching between three measurement lines (L1, L2, L3), plus an OFF (0) position. Useful for selecting which line your measuring instrument monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"817\" data-end=\"975\"\u003e\n\u003cp data-start=\"819\" data-end=\"975\"\u003e\u003cstrong data-start=\"819\" data-end=\"842\"\u003e90° Switching Angle\u003c\/strong\u003e\u003cbr data-start=\"842\" data-end=\"845\"\u003eDistinct positions at 0°, 90°, 180°, and 270°, giving clear feedback and stable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"977\" data-end=\"1137\"\u003e\n\u003cp data-start=\"979\" data-end=\"1137\"\u003e\u003cstrong data-start=\"979\" data-end=\"994\"\u003e12 A Rating\u003c\/strong\u003e\u003cbr data-start=\"994\" data-end=\"997\"\u003eRated for a conventional free-air thermal current of \u003cstrong data-start=\"1052\" data-end=\"1060\"\u003e12 A\u003c\/strong\u003e, suitable for many panel applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1139\" data-end=\"1436\"\u003e\n\u003cp data-start=\"1141\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1141\" data-end=\"1205\"\u003eFront Mounting, Multifixing Design with 45×45 mm Front Plate\u003c\/strong\u003e\u003cbr data-start=\"1205\" data-end=\"1208\"\u003eIncludes a standard front plate (45 mm × 45 mm), enabling installation into standard panel cutouts. The black 35 mm handle with metallic legend (“0 – L1 – L2 – L3”) ensures clear labeling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1438\" data-end=\"1541\"\u003e\n\u003cp data-start=\"1440\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1440\" data-end=\"1454\"\u003eDurability\u003c\/strong\u003e\u003cbr data-start=\"1454\" data-end=\"1457\"\u003eMechanical life rated at ≈ 1,000,000 cycles.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1677\"\u003e\n\u003cp data-start=\"1545\" data-end=\"1677\"\u003e\u003cstrong data-start=\"1545\" data-end=\"1566\"\u003eProtection Rating\u003c\/strong\u003e\u003cbr data-start=\"1566\" data-end=\"1569\"\u003eIP40 protected: guards against solid objects but not water exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1828\"\u003e\n\u003cp data-start=\"1681\" data-end=\"1828\"\u003e\u003cstrong data-start=\"1681\" data-end=\"1711\"\u003eInsulation \u0026amp; Rated Voltage\u003c\/strong\u003e\u003cbr data-start=\"1711\" data-end=\"1714\"\u003eInsulation voltage up to 690 V, with pollution degree 3 per IEC standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1830\" data-end=\"1833\"\u003e\n\u003ch3 data-start=\"1835\" data-end=\"1873\"\u003eTechnical Specifications (Summary)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1875\" data-end=\"2595\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1875\" data-end=\"1900\"\u003e\n\u003ctr data-start=\"1875\" data-end=\"1900\"\u003e\n\u003cth data-start=\"1875\" data-end=\"1891\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1891\" data-end=\"1900\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1916\" data-end=\"2595\"\u003e\n\u003ctr data-start=\"1916\" data-end=\"1949\"\u003e\n\u003ctd data-start=\"1916\" data-end=\"1924\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1924\" data-end=\"1949\" data-col-size=\"md\"\u003eK1F003MLH (Harmony K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1950\" data-end=\"2011\"\u003e\n\u003ctd data-start=\"1950\" data-end=\"1961\" data-col-size=\"sm\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-start=\"1961\" data-end=\"2011\" data-col-size=\"md\"\u003eCam ammeter selector switch — 3 circuits + OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2012\" data-end=\"2070\"\u003e\n\u003ctd data-start=\"2012\" data-end=\"2031\" data-col-size=\"sm\"\u003ePoles \/ Circuits\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2031\" data-end=\"2070\"\u003e3 measurement circuits (L1, L2, L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2071\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2071\" data-end=\"2083\" data-col-size=\"sm\"\u003ePositions\u003c\/td\u003e\n\u003ctd data-start=\"2083\" data-end=\"2122\" data-col-size=\"md\"\u003e4 stable positions: OFF, L1, L2, L3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2181\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2141\" data-col-size=\"sm\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2141\" data-end=\"2181\"\u003e90° between positions (0–90–180–270)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2182\" data-end=\"2233\"\u003e\n\u003ctd data-start=\"2182\" data-end=\"2198\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-start=\"2198\" data-end=\"2233\" data-col-size=\"md\"\u003e12 A (free-air thermal current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2234\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2234\" data-end=\"2260\" data-col-size=\"sm\"\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-start=\"2260\" data-end=\"2271\" data-col-size=\"md\"\u003e~ 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2338\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2283\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"2283\" data-end=\"2338\" data-col-size=\"md\"\u003eFront mount, multifixing, with front plate 45×45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2339\" data-end=\"2412\"\u003e\n\u003ctd data-start=\"2339\" data-end=\"2348\" data-col-size=\"sm\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-start=\"2348\" data-end=\"2412\" data-col-size=\"md\"\u003eBlack, 35 mm rotary handle with metallic legend “0-L1-L2-L3”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2413\" data-end=\"2453\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2431\" data-col-size=\"sm\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd data-start=\"2431\" data-end=\"2453\" data-col-size=\"md\"\u003e≈ 1,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2454\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2454\" data-end=\"2467\" data-col-size=\"sm\"\u003eProtection\u003c\/td\u003e\n\u003ctd data-start=\"2467\" data-end=\"2492\" data-col-size=\"md\"\u003eIP40 (front and body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2595\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2505\" data-col-size=\"sm\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2595\" data-col-size=\"md\"\u003eConforms to IEC\/EN 60947-1, IEC\/EN 60947-3, etc.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2597\" data-end=\"2600\"\u003e\n\u003ch3 data-start=\"2602\" data-end=\"2624\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"2626\" data-end=\"2971\"\u003e\n\u003cli data-start=\"2626\" data-end=\"2728\"\u003e\n\u003cp data-start=\"2628\" data-end=\"2728\"\u003ePanel meters and ammeter circuits where you need to select which phase (L1, L2, or L3) to monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2729\" data-end=\"2801\"\u003e\n\u003cp data-start=\"2731\" data-end=\"2801\"\u003eElectrical distribution boards in industrial or commercial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2802\" data-end=\"2888\"\u003e\n\u003cp data-start=\"2804\" data-end=\"2888\"\u003eMaintenance setups where monitoring different circuits is needed without rewiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2889\" data-end=\"2971\"\u003e\n\u003cp data-start=\"2891\" data-end=\"2971\"\u003eSituations where clarity and durability of measurement switching are critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230563766555,"sku":"K1F003MLH","price":45.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1f003mlh-k1f003mlh-harmony-k_5b60aa01-fc03-4509-9fa1-4ce55e52775d.jpg?v=1777185522"},{"product_id":"schneider-electric-k1f003ulh-harmony-k","title":"Schneider Electric K1F003ULH Harmony K","description":"\u003cp data-start=\"207\" data-end=\"533\"\u003eThe \u003cstrong data-start=\"211\" data-end=\"243\"\u003eSchneider Electric K1F003ULH\u003c\/strong\u003e is a reliable 3-pole cam changeover switch from the Harmony K line. With a 12 A rating and changeover capability (“2-0-1” positions), this switch is ideal for control of power sources, switching between circuits, or isolating sections of an installation in industrial or commercial panels.\u003c\/p\u003e\n\u003chr data-start=\"535\" data-end=\"538\"\u003e\n\u003ch3 data-start=\"540\" data-end=\"567\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"569\" data-end=\"2252\"\u003e\n\u003cli data-start=\"569\" data-end=\"777\"\u003e\n\u003cp data-start=\"571\" data-end=\"777\"\u003e\u003cstrong data-start=\"571\" data-end=\"599\"\u003e3-Pole Changeover Design\u003c\/strong\u003e\u003cbr data-start=\"599\" data-end=\"602\"\u003eThe “2-0-1” marking denotes two ON positions (2 and 1) with an OFF (0) center, allowing safe switching between two sources or circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"779\" data-end=\"890\"\u003e\n\u003cp data-start=\"781\" data-end=\"890\"\u003e\u003cstrong data-start=\"781\" data-end=\"804\"\u003e12 A Current Rating\u003c\/strong\u003e\u003cbr data-start=\"804\" data-end=\"807\"\u003eRated at 12 A, suitable for moderate loads.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"892\" data-end=\"1053\"\u003e\n\u003cp data-start=\"894\" data-end=\"1053\"\u003e\u003cstrong data-start=\"894\" data-end=\"917\"\u003eSwitching Angle 45°\u003c\/strong\u003e\u003cbr data-start=\"917\" data-end=\"920\"\u003eProvides a 45° travel for switching between OFF and ON positions (left\/right 0-315° \/ 0-45°).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1055\" data-end=\"1251\"\u003e\n\u003cp data-start=\"1057\" data-end=\"1251\"\u003e\u003cstrong data-start=\"1057\" data-end=\"1104\"\u003eFront Mount Plate (45 × 45 mm), Multifixing\u003c\/strong\u003e\u003cbr data-start=\"1104\" data-end=\"1107\"\u003eMounts neatly into standard panel cutouts using its front plate, allowing flexible installation methods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1418\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1418\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1284\"\u003eDurable Handle and Legend\u003c\/strong\u003e\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eEquipped with a black 35 mm rotary handle and metallic legend indicating positions “2-0-1”.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1596\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1463\"\u003eRated Insulation Voltage \u0026amp; Protection\u003c\/strong\u003e\u003cbr data-start=\"1463\" data-end=\"1466\"\u003eInsulation rated for 690 V, pollution degree 3 per IEC 60947-1. Protection rating is IP40.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1801\"\u003e\n\u003cp data-start=\"1600\" data-end=\"1801\"\u003e\u003cstrong data-start=\"1600\" data-end=\"1629\"\u003eTerminal \u0026amp; Wiring Details\u003c\/strong\u003e\u003cbr data-start=\"1629\" data-end=\"1632\"\u003eIncludes screw clamp (captive) terminals. Capacity includes flexible conductors (2 × 1.5 mm²) and solid conductors (1 × 2.5 mm²).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1803\" data-end=\"2039\"\u003e\n\u003cp data-start=\"1805\" data-end=\"2039\"\u003e\u003cstrong data-start=\"1805\" data-end=\"1843\"\u003eMechanical \u0026amp; Electrical Durability\u003c\/strong\u003e\u003cbr data-start=\"1843\" data-end=\"1846\"\u003eDesigned for high mechanical life (≈ 1,000,000 cycles in some utilization categories) with good performance under IEC AC-3 \/ AC-21 \/ AC-23A duty ratings.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2252\"\u003e\n\u003cp data-start=\"2043\" data-end=\"2080\"\u003e\u003cstrong data-start=\"2043\" data-end=\"2078\"\u003eOperating \u0026amp; Environmental Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2083\" data-end=\"2252\"\u003e\n\u003cli data-start=\"2083\" data-end=\"2173\"\u003e\n\u003cp data-start=\"2085\" data-end=\"2173\"\u003eAmbient temperature (operation): -25 °C … +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2252\"\u003e\n\u003cp data-start=\"2178\" data-end=\"2252\"\u003eStorage temperature: -40 °C … +70 °C\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2254\" data-end=\"2257\"\u003e\n\u003ch3 data-start=\"2259\" data-end=\"2295\"\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2297\" data-end=\"2941\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2297\" data-end=\"2322\"\u003e\n\u003ctr data-start=\"2297\" data-end=\"2322\"\u003e\n\u003cth data-start=\"2297\" data-end=\"2313\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2313\" data-end=\"2322\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2338\" data-end=\"2941\"\u003e\n\u003ctr data-start=\"2338\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2338\" data-end=\"2346\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2346\" data-end=\"2374\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"2348\" data-end=\"2361\"\u003eK1F003ULH\u003c\/strong\u003e, Harmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2388\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2383\" data-col-size=\"sm\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-start=\"2383\" data-end=\"2388\" data-col-size=\"md\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2389\" data-end=\"2456\"\u003e\n\u003ctd data-start=\"2389\" data-end=\"2410\" data-col-size=\"sm\"\u003ePositions \/ Legend\u003c\/td\u003e\n\u003ctd data-start=\"2410\" data-end=\"2456\" data-col-size=\"md\"\u003e“2-0-1” (Changeover with OFF mid position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2457\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2457\" data-end=\"2475\" data-col-size=\"sm\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-start=\"2475\" data-end=\"2482\" data-col-size=\"md\"\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2513\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2505\" data-col-size=\"sm\"\u003eRated Current (Ith)\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2513\" data-col-size=\"md\"\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2514\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2514\" data-end=\"2546\" data-col-size=\"sm\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-start=\"2546\" data-end=\"2555\" data-col-size=\"md\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2600\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2573\" data-col-size=\"sm\"\u003eMounting Plate\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2600\" data-col-size=\"md\"\u003e45 × 45 mm, multifixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2601\" data-end=\"2633\"\u003e\n\u003ctd data-start=\"2601\" data-end=\"2610\" data-col-size=\"sm\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-start=\"2610\" data-end=\"2633\" data-col-size=\"md\"\u003eBlack, 35 mm rotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2634\" data-end=\"2662\"\u003e\n\u003ctd data-start=\"2634\" data-end=\"2654\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-start=\"2654\" data-end=\"2662\" data-col-size=\"md\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2663\" data-end=\"2725\"\u003e\n\u003ctd data-start=\"2663\" data-end=\"2677\" data-col-size=\"sm\"\u003eSwitch Type\u003c\/td\u003e\n\u003ctd data-start=\"2677\" data-end=\"2725\" data-col-size=\"md\"\u003eCam changeover, slow-break with OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2726\" data-end=\"2799\"\u003e\n\u003ctd data-start=\"2726\" data-end=\"2738\" data-col-size=\"sm\"\u003eTerminals\u003c\/td\u003e\n\u003ctd data-start=\"2738\" data-end=\"2799\" data-col-size=\"md\"\u003eCaptive screw clamps: flexible 2×1.5 mm², solid 1×2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2800\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2818\" data-col-size=\"sm\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd data-start=\"2818\" data-end=\"2861\" data-col-size=\"md\"\u003e≈ 1,000,000 cycles (depending on usage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2906\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2887\" data-col-size=\"sm\"\u003eAmbient Operation Temp\u003c\/td\u003e\n\u003ctd data-start=\"2887\" data-end=\"2906\" data-col-size=\"md\"\u003e-25 °C … +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2907\" data-end=\"2941\"\u003e\n\u003ctd data-start=\"2907\" data-end=\"2922\" data-col-size=\"sm\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd data-start=\"2922\" data-end=\"2941\" data-col-size=\"md\"\u003e-40 °C … +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2943\" data-end=\"2946\"\u003e\n\u003ch3 data-start=\"2948\" data-end=\"2970\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"2972\" data-end=\"3319\"\u003e\n\u003cli data-start=\"2972\" data-end=\"3064\"\u003e\n\u003cp data-start=\"2974\" data-end=\"3064\"\u003eSwitching between two power sources or supply circuits in control or distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3065\" data-end=\"3155\"\u003e\n\u003cp data-start=\"3067\" data-end=\"3155\"\u003eElectrical isolation and changeover in motor control centers or machine control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3156\" data-end=\"3203\"\u003e\n\u003cp data-start=\"3158\" data-end=\"3203\"\u003eBackup or redundant power switching systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3204\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3206\" data-end=\"3319\"\u003eIndustrial or commercial installations where robustness, clear positions, and a compact footprint are important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230563897627,"sku":"K1F003ULH","price":39.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1f003ulh-k1f003ulh-harmony-k_5eb7c682-353d-4eab-86b7-0d77168e2770.jpg?v=1777185526"},{"product_id":"schneider-electric-k1f027mlh-harmony-k","title":"Schneider Electric K1F027MLH Harmony K","description":"\u003cp data-start=\"227\" data-end=\"597\"\u003eMonitor voltages accurately and safely with the \u003cstrong data-start=\"275\" data-end=\"307\"\u003eSchneider Electric K1F027MLH\u003c\/strong\u003e voltmeter cam switch from the Harmony K range. This switch is designed for switchboards and distribution panels where selecting between phase-to-phase and phase-to-neutral voltage measurements is required. Ideal for professional applications in industrial, commercial, or utility settings.\u003c\/p\u003e\n\u003chr data-start=\"599\" data-end=\"602\"\u003e\n\u003ch3 data-start=\"604\" data-end=\"631\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"633\" data-end=\"2139\"\u003e\n\u003cli data-start=\"633\" data-end=\"856\"\u003e\n\u003cp data-start=\"635\" data-end=\"856\"\u003e\u003cstrong data-start=\"635\" data-end=\"666\"\u003e7-Position Voltmeter Switch\u003c\/strong\u003e\u003cbr data-start=\"666\" data-end=\"669\"\u003eOffers multiple voltage measurement selections: phase-to-phase (L1-L2, L2-L3, L3-L1) and phase-to-neutral (L1-N, L2-N, L3-N), plus an OFF position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"858\" data-end=\"1059\"\u003e\n\u003cp data-start=\"860\" data-end=\"1059\"\u003e\u003cstrong data-start=\"860\" data-end=\"897\"\u003eHigh Current \u0026amp; Insulation Ratings\u003c\/strong\u003e\u003cbr data-start=\"897\" data-end=\"900\"\u003eRated for \u003cstrong data-start=\"912\" data-end=\"964\"\u003e12 A conventional free-air thermal current (Ith)\u003c\/strong\u003e. Insulation voltage up to \u003cstrong data-start=\"991\" data-end=\"1000\"\u003e690 V\u003c\/strong\u003e, pollution degree 3.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1292\"\u003e\n\u003cp data-start=\"1063\" data-end=\"1292\"\u003e\u003cstrong data-start=\"1063\" data-end=\"1101\"\u003eDesigned for Accurate Measurements\u003c\/strong\u003e\u003cbr data-start=\"1101\" data-end=\"1104\"\u003eEnables switching between different voltage legs or neutral for flexible monitoring. Provides precision in control room or switchboard environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1294\" data-end=\"1555\"\u003e\n\u003cp data-start=\"1296\" data-end=\"1555\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1336\"\u003eFront-Mounting \u0026amp; Standard Plate Size\u003c\/strong\u003e\u003cbr data-start=\"1336\" data-end=\"1339\"\u003eMounts from the front using a \u003cstrong data-start=\"1371\" data-end=\"1403\"\u003e45 × 45 mm multifixing plate\u003c\/strong\u003e. Features a black 35 mm handle, with a clearly marked metallic legend “0 – L1N – L2N – L3N – L1L2 – L2L3 – L3L1”.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1557\" data-end=\"1695\"\u003e\n\u003cp data-start=\"1559\" data-end=\"1695\"\u003e\u003cstrong data-start=\"1559\" data-end=\"1585\"\u003eDurability \u0026amp; Long Life\u003c\/strong\u003e\u003cbr data-start=\"1585\" data-end=\"1588\"\u003eBuilt for mechanical longevity: approximately \u003cstrong data-start=\"1636\" data-end=\"1656\"\u003e1,000,000 cycles\u003c\/strong\u003e.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1916\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1916\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1730\"\u003eRobust Standards Compliance\u003c\/strong\u003e\u003cbr data-start=\"1730\" data-end=\"1733\"\u003eConforms to IEC\/EN standards (such as IEC 60947-1, power circuit switch standards etc.). Offers IP40 protection rating. No padlocking facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1918\" data-end=\"2139\"\u003e\n\u003cp data-start=\"1920\" data-end=\"2139\"\u003e\u003cstrong data-start=\"1920\" data-end=\"1949\"\u003eEnvironmentally Resilient\u003c\/strong\u003e\u003cbr data-start=\"1949\" data-end=\"1952\"\u003eOperates reliably between -25 °C and +55 °C; storage down to -40 °C and up to +70 °C. Designed to withstand vibration and shock per IEC procedures.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2141\" data-end=\"2144\"\u003e\n\u003ch3 data-start=\"2146\" data-end=\"2174\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2176\" data-end=\"2713\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2176\" data-end=\"2201\"\u003e\n\u003ctr data-start=\"2176\" data-end=\"2201\"\u003e\n\u003cth data-start=\"2176\" data-end=\"2192\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2192\" data-end=\"2201\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2216\" data-end=\"2713\"\u003e\n\u003ctr data-start=\"2216\" data-end=\"2279\"\u003e\n\u003ctd data-start=\"2216\" data-end=\"2224\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2224\" data-end=\"2279\"\u003e\u003cstrong data-start=\"2226\" data-end=\"2277\"\u003eSchneider Electric K1F027MLH (Harmony K series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2280\" data-end=\"2340\"\u003e\n\u003ctd data-start=\"2280\" data-end=\"2291\" data-col-size=\"sm\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-start=\"2291\" data-end=\"2340\" data-col-size=\"md\"\u003eVoltmeter selector switch (7 positions + OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2341\" data-end=\"2372\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2364\" data-col-size=\"sm\"\u003eCurrent Rating (Ith)\u003c\/td\u003e\n\u003ctd data-start=\"2364\" data-end=\"2372\" data-col-size=\"md\"\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2373\" data-end=\"2408\"\u003e\n\u003ctd data-start=\"2373\" data-end=\"2399\" data-col-size=\"sm\"\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2399\" data-end=\"2408\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2409\" data-end=\"2433\"\u003e\n\u003ctd data-start=\"2409\" data-end=\"2428\" data-col-size=\"sm\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2433\" data-col-size=\"md\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2434\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2434\" data-end=\"2445\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"2445\" data-end=\"2492\" data-col-size=\"md\"\u003eFront mounted, multifixing plate 45 × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2554\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2502\" data-col-size=\"sm\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2554\" data-col-size=\"md\"\u003eBlack, 35 mm rotary handle, with metallic legend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2555\" data-end=\"2593\"\u003e\n\u003ctd data-start=\"2555\" data-end=\"2568\" data-col-size=\"sm\"\u003eProtection\u003c\/td\u003e\n\u003ctd data-start=\"2568\" data-end=\"2593\" data-col-size=\"md\"\u003eIP40 (front and body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2594\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2594\" data-end=\"2618\" data-col-size=\"sm\"\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd data-start=\"2618\" data-end=\"2639\" data-col-size=\"md\"\u003e~1,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2640\" data-end=\"2677\"\u003e\n\u003ctd data-start=\"2640\" data-end=\"2658\" data-col-size=\"sm\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd data-start=\"2658\" data-end=\"2677\" data-col-size=\"md\"\u003e-25 °C … +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2678\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2678\" data-end=\"2694\" data-col-size=\"sm\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd data-start=\"2694\" data-end=\"2713\" data-col-size=\"md\"\u003e-40 °C … +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2715\" data-end=\"2718\"\u003e\n\u003ch3 data-start=\"2720\" data-end=\"2744\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2746\" data-end=\"3096\"\u003e\n\u003cli data-start=\"2746\" data-end=\"2850\"\u003e\n\u003cp data-start=\"2748\" data-end=\"2850\"\u003eSwitchboards and distribution panels needing to measure phase-to-phase and phase-to-neutral voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2851\" data-end=\"2966\"\u003e\n\u003cp data-start=\"2853\" data-end=\"2966\"\u003eElectrical control rooms where monitoring of different voltage lines is required for diagnostics or maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2967\" data-end=\"3096\"\u003e\n\u003cp data-start=\"2969\" data-end=\"3096\"\u003eIndustrial or utility environments where a reliable selector for voltage measurements improves safety and monitoring accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230564716827,"sku":"K1F027MLH","price":43.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k1f027mlh-k1f027mlh-harmony-k_cff2fa64-4b52-4cfd-885b-395cea281ba9.jpg?v=1777185530"},{"product_id":"schneider-electric-k2a001alh-harmony-k","title":"Schneider Electric K2A001ALH Harmony K","description":"\u003cp data-end=\"521\" data-start=\"210\"\u003eThe \u003cstrong data-end=\"246\" data-start=\"214\"\u003eSchneider Electric K2A001ALH\u003c\/strong\u003e is a reliable 1-pole cam switch from the Harmony K line, engineered to provide robust ON\/OFF functionality with high current capacity and durable construction. Ideal for industrial and panel-mounted applications where dependable switching and clear operation are required.\u003c\/p\u003e\n\u003chr data-end=\"526\" data-start=\"523\"\u003e\n\u003ch3 data-end=\"555\" data-start=\"528\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-end=\"2296\" data-start=\"557\"\u003e\n\u003cli data-end=\"716\" data-start=\"557\"\u003e\n\u003cp data-end=\"716\" data-start=\"559\"\u003e\u003cstrong data-end=\"594\" data-start=\"559\"\u003e1-Pole, 2-Position Switch (0-1)\u003c\/strong\u003e\u003cbr data-end=\"597\" data-start=\"594\"\u003eOffers two stable positions (“0” = OFF, “1” = ON) with a 45° switching angle. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"878\" data-start=\"718\"\u003e\n\u003cp data-end=\"878\" data-start=\"720\"\u003e\u003cstrong data-end=\"768\" data-start=\"720\"\u003eRated for 20 A Conventional Free-Air Current\u003c\/strong\u003e\u003cbr data-end=\"771\" data-start=\"768\"\u003eHandles up to \u003cstrong data-end=\"795\" data-start=\"787\"\u003e20 A\u003c\/strong\u003e under free-air thermal current conditions. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1123\" data-start=\"880\"\u003e\n\u003cp data-end=\"1123\" data-start=\"882\"\u003e\u003cstrong data-end=\"917\" data-start=\"882\"\u003eMultifixing, Front-Mount Design\u003c\/strong\u003e\u003cbr data-end=\"920\" data-start=\"917\"\u003eFeatures a front plate of \u003cstrong data-end=\"962\" data-start=\"948\"\u003e45 × 45 mm\u003c\/strong\u003e with “multifixing” mounting style, allowing flexible installation. Black 35 mm rotary handle with metallic legend “0-1”.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1312\" data-start=\"1125\"\u003e\n\u003cp data-end=\"1312\" data-start=\"1127\"\u003e\u003cstrong data-end=\"1164\" data-start=\"1127\"\u003eHigh Insulation \u0026amp; Voltage Ratings\u003c\/strong\u003e\u003cbr data-end=\"1167\" data-start=\"1164\"\u003eRated insulation voltage (Ui) of \u003cstrong data-end=\"1211\" data-start=\"1202\"\u003e690 V\u003c\/strong\u003e, pollution degree 3. Suitable for industrial power circuits.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1575\" data-start=\"1314\"\u003e\n\u003cp data-end=\"1350\" data-start=\"1316\"\u003e\u003cstrong data-end=\"1348\" data-start=\"1316\"\u003eDurability \u0026amp; Mechanical Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1575\" data-start=\"1353\"\u003e\n\u003cli data-end=\"1434\" data-start=\"1353\"\u003e\n\u003cp data-end=\"1434\" data-start=\"1355\"\u003eMechanical life: ~ \u003cstrong data-end=\"1394\" data-start=\"1374\"\u003e1,000,000 cycles\u003c\/strong\u003e\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1575\" data-start=\"1437\"\u003e\n\u003cp data-end=\"1575\" data-start=\"1439\"\u003eElectrical durability varies by load type (e.g. AC-15, AC-3, etc.) for many thousands of cycles.\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1938\" data-start=\"1577\"\u003e\n\u003cp data-end=\"1614\" data-start=\"1579\"\u003e\u003cstrong data-end=\"1612\" data-start=\"1579\"\u003eProtection \u0026amp; Physical Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1938\" data-start=\"1617\"\u003e\n\u003cli data-end=\"1764\" data-start=\"1617\"\u003e\n\u003cp data-end=\"1764\" data-start=\"1619\"\u003eProtection rating: \u003cstrong data-end=\"1646\" data-start=\"1638\"\u003eIP40\u003c\/strong\u003e (front) — adequate for protection against solid objects, less so for liquids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1875\" data-start=\"1767\"\u003e\n\u003cp data-end=\"1875\" data-start=\"1769\"\u003eDimensions: approx. 45 mm × 45 mm × 77 mm (width × height × depth) \u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003ca class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out\" alt=\"https:\/\/docs.rs-online.com\/4154\/A700000014390562.pdf?utm_source=chatgpt.com\" rel=\"noopener\" href=\"https:\/\/docs.rs-online.com\/4154\/A700000014390562.pdf?utm_source=chatgpt.com\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between absolute\"\u003e\u003cspan class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1938\" data-start=\"1878\"\u003e\n\u003cp data-end=\"1938\" data-start=\"1880\"\u003eWeight: ~ 0.103 kg\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2296\" data-start=\"1940\"\u003e\n\u003cp data-end=\"1985\" data-start=\"1942\"\u003e\u003cstrong data-end=\"1983\" data-start=\"1942\"\u003eTemperature \u0026amp; Environmental Endurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2296\" data-start=\"1988\"\u003e\n\u003cli data-end=\"2077\" data-start=\"1988\"\u003e\n\u003cp data-end=\"2077\" data-start=\"1990\"\u003eOperating ambient temperature: -25 °C to +55 °C\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2149\" data-start=\"2080\"\u003e\n\u003cp data-end=\"2149\" data-start=\"2082\"\u003eStorage: -40 °C to +70 °C\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2296\" data-start=\"2152\"\u003e\n\u003cp data-end=\"2296\" data-start=\"2154\"\u003eResistance to shock and vibration: meets relevant IEC standards (e.g. vibration ~5 gn, shock ~30 gn)\u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2301\" data-start=\"2298\"\u003e\n\u003ch3 data-end=\"2341\" data-start=\"2303\"\u003eTechnical Specifications (Summary)\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2923\" data-start=\"2343\"\u003e\n\u003cthead data-end=\"2368\" data-start=\"2343\"\u003e\n\u003ctr data-end=\"2368\" data-start=\"2343\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2359\" data-start=\"2343\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"2368\" data-start=\"2359\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2923\" data-start=\"2396\"\u003e\n\u003ctr data-end=\"2452\" data-start=\"2396\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2404\" data-start=\"2396\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2452\" data-start=\"2404\"\u003eSchneider Electric \u003cstrong data-end=\"2438\" data-start=\"2425\"\u003eK2A001ALH\u003c\/strong\u003e (Harmony K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2467\" data-start=\"2453\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2461\" data-start=\"2453\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2467\" data-start=\"2461\"\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2491\" data-start=\"2468\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2480\" data-start=\"2468\"\u003ePositions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2491\" data-start=\"2480\"\u003e2 (0-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2517\" data-start=\"2492\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2510\" data-start=\"2492\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-end=\"2517\" data-start=\"2510\" data-col-size=\"md\"\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2554\" data-start=\"2518\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2535\" data-start=\"2518\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2554\" data-start=\"2535\"\u003e20 A (free-air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2585\" data-start=\"2555\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2572\" data-start=\"2555\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2585\" data-start=\"2572\"\u003e~690 V Ui\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2648\" data-start=\"2586\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2603\" data-start=\"2586\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2648\" data-start=\"2603\"\u003eFront mounting, multi-fix, plate 45×45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2714\" data-start=\"2649\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2658\" data-start=\"2649\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2714\" data-start=\"2658\"\u003e35 mm black rotary handle with metallic “0-1” legend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2744\" data-start=\"2715\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2736\" data-start=\"2715\"\u003eProtection (Front)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2744\" data-start=\"2736\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2784\" data-start=\"2745\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2763\" data-start=\"2745\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2784\" data-start=\"2763\"\u003e~1,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2849\" data-start=\"2785\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2808\" data-start=\"2785\"\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2849\" data-start=\"2808\"\u003eVaries by category (AC-15, AC-3 etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2887\" data-start=\"2850\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2867\" data-start=\"2850\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2887\" data-start=\"2867\"\u003e-25 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2923\" data-start=\"2888\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2903\" data-start=\"2888\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2923\" data-start=\"2903\"\u003e-40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2928\" data-start=\"2925\"\u003e\n\u003ch3 data-end=\"2952\" data-start=\"2930\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-end=\"3349\" data-start=\"2954\"\u003e\n\u003cli data-end=\"3056\" data-start=\"2954\"\u003e\n\u003cp data-end=\"3056\" data-start=\"2956\"\u003eON\/OFF switching for industrial panels or machinery where a single position selector is sufficient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3143\" data-start=\"3057\"\u003e\n\u003cp data-end=\"3143\" data-start=\"3059\"\u003eControl circuits in automation setups needing reliable, clearly labelled switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3243\" data-start=\"3144\"\u003e\n\u003cp data-end=\"3243\" data-start=\"3146\"\u003eReplacement of older switches in control cabinets or equipment using standard mounting cut-outs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3349\" data-start=\"3244\"\u003e\n\u003cp data-end=\"3349\" data-start=\"3246\"\u003eEnvironments where moderate exposure to dust or inert solids exists, but not heavy moisture or splash\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230567043355,"sku":"K2A001ALH","price":21.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2a001alh-k2a001alh-harmony-k_06a1dd90-699c-48d3-813a-4ca260db9849.jpg?v=1777185534"},{"product_id":"schneider-electric-k2b001ulh-harmony-k","title":"Schneider Electric K2B001ULH Harmony K","description":"\u003cp data-end=\"548\" data-start=\"231\"\u003eUpgrade your control panel’s switching capabilities with the \u003cstrong data-end=\"324\" data-start=\"292\"\u003eSchneider Electric K2B001ULH\u003c\/strong\u003e, a robust cam changeover switch in the Harmony K line. Engineered for dependable performance and rugged use, this 1-pole switch is ideal for industrial and automation applications where clear OFF-ON-OFF switching is needed.\u003c\/p\u003e\n\u003chr data-end=\"553\" data-start=\"550\"\u003e\n\u003ch3 data-end=\"582\" data-start=\"555\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-end=\"2558\" data-start=\"584\"\u003e\n\u003cli data-end=\"805\" data-start=\"584\"\u003e\n\u003cp data-end=\"805\" data-start=\"586\"\u003e\u003cstrong data-end=\"627\" data-start=\"586\"\u003e20 A (One-Pole) Changeover Capability\u003c\/strong\u003e\u003cbr data-end=\"630\" data-start=\"627\"\u003eRated for \u003cstrong data-end=\"688\" data-start=\"642\"\u003e20 A conventional free-air thermal current\u003c\/strong\u003e (1P), making it appropriate for control circuits and moderate power switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"972\" data-start=\"807\"\u003e\n\u003cp data-end=\"972\" data-start=\"809\"\u003e\u003cstrong data-end=\"843\" data-start=\"809\"\u003eMultifixing Front-Mount Design\u003c\/strong\u003e\u003cbr data-end=\"846\" data-start=\"843\"\u003eIncludes a \u003cstrong data-end=\"885\" data-start=\"859\"\u003e45 × 45 mm front plate\u003c\/strong\u003e, allowing flexible mounting options (multi-fix). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003cspan data-testid=\"webpage-citation-pill\" class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003ca class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out\" alt=\"https:\/\/datasheet.octopart.com\/K2B001ULH-Schneider-Electric-datasheet-180639678.pdf?utm_source=chatgpt.com\" rel=\"noopener\" href=\"https:\/\/datasheet.octopart.com\/K2B001ULH-Schneider-Electric-datasheet-180639678.pdf?utm_source=chatgpt.com\" target=\"_blank\"\u003e\u003cspan class=\"relative start-0 bottom-0 flex h-full w-full items-center\"\u003e\u003cspan class=\"flex h-4 w-full items-center justify-between\"\u003e\u003cspan class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1254\" data-start=\"974\"\u003e\n\u003cp data-end=\"1254\" data-start=\"976\"\u003e\u003cstrong data-end=\"1036\" data-start=\"976\"\u003eSwitching Positions 2-0-1 (Changeover with OFF Position)\u003c\/strong\u003e\u003cbr data-end=\"1039\" data-start=\"1036\"\u003eMarked “2-0-1” metallic legend. Provides two ON positions (2 and 1) with an OFF (0) position in between. Useful for safely isolating circuits or selecting between two sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1405\" data-start=\"1256\"\u003e\n\u003cp data-end=\"1405\" data-start=\"1258\"\u003e\u003cstrong data-end=\"1287\" data-start=\"1258\"\u003eHandle \u0026amp; Operator Details\u003c\/strong\u003e\u003cbr data-end=\"1290\" data-start=\"1287\"\u003eEquipped with a 35 mm black rotary handle. No padlocking facility provided.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1825\" data-start=\"1407\"\u003e\n\u003cp data-end=\"1442\" data-start=\"1409\"\u003e\u003cstrong data-end=\"1440\" data-start=\"1409\"\u003eDurable \u0026amp; Safe Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1825\" data-start=\"1445\"\u003e\n\u003cli data-end=\"1563\" data-start=\"1445\"\u003e\n\u003cp data-end=\"1563\" data-start=\"1447\"\u003eRated insulation voltage up to 690 V (pollution degree 3) per IEC standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1714\" data-start=\"1566\"\u003e\n\u003cp data-end=\"1714\" data-start=\"1568\"\u003eIP40 protection (front \u0026amp; body) – suitable for indoor environments with minimal exposure to liquid ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1825\" data-start=\"1717\"\u003e\n\u003cp data-end=\"1825\" data-start=\"1719\"\u003eMechanical durability: about \u003cstrong data-end=\"1768\" data-start=\"1748\"\u003e1,000,000 cycles\u003c\/strong\u003e under rated use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2027\" data-start=\"1827\"\u003e\n\u003cp data-end=\"2027\" data-start=\"1829\"\u003e\u003cstrong data-end=\"1860\" data-start=\"1829\"\u003eSwitching Angle \u0026amp; Positions\u003c\/strong\u003e\u003cbr data-end=\"1863\" data-start=\"1860\"\u003eProvides a switching angle of \u003cstrong data-end=\"1902\" data-start=\"1895\"\u003e45°\u003c\/strong\u003e. The “Left” position is approx. 315° from OFF, the “Right” position at 45° from OFF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2327\" data-start=\"2029\"\u003e\n\u003cp data-end=\"2327\" data-start=\"2031\"\u003e\u003cstrong data-end=\"2065\" data-start=\"2031\"\u003eElectrical Ratings \u0026amp; Endurance\u003c\/strong\u003e\u003cbr data-end=\"2068\" data-start=\"2065\"\u003eGood performance under various duty categories (AC-15, AC-21, AC-3 etc.), with durability at thousands of cycles depending on usage. Short-circuit rating up to 10,000 A (with proper protection) is noted in datasheets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2558\" data-start=\"2329\"\u003e\n\u003cp data-end=\"2558\" data-start=\"2331\"\u003e\u003cstrong data-end=\"2373\" data-start=\"2331\"\u003eOperating and Environmental Conditions\u003c\/strong\u003e\u003cbr data-end=\"2376\" data-start=\"2373\"\u003eOperates safely between \u003cstrong data-end=\"2423\" data-start=\"2402\"\u003e–25 °C and +55 °C\u003c\/strong\u003e, with storage from –40 °C to +70 °C. Withstands typical industrial vibration and shock levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2563\" data-start=\"2560\"\u003e\n\u003ch3 data-end=\"2605\" data-start=\"2565\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3159\" data-start=\"2607\"\u003e\n\u003cthead data-end=\"2638\" data-start=\"2607\"\u003e\n\u003ctr data-end=\"2638\" data-start=\"2607\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2623\" data-start=\"2607\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"2638\" data-start=\"2623\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3159\" data-start=\"2659\"\u003e\n\u003ctr data-end=\"2692\" data-start=\"2659\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2667\" data-start=\"2659\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2692\" data-start=\"2667\"\u003eK2B001ULH (Harmony K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2718\" data-start=\"2693\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2701\" data-start=\"2693\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2718\" data-start=\"2701\"\u003e1P (one pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2784\" data-start=\"2719\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2741\" data-start=\"2719\"\u003eSwitching Positions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2784\" data-start=\"2741\"\u003e3 positions: “2-0-1” with OFF in middle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2832\" data-start=\"2785\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2807\" data-start=\"2785\"\u003eRated Current (Ith)\u003c\/td\u003e\n\u003ctd data-end=\"2832\" data-start=\"2807\" data-col-size=\"md\"\u003e20 A free-air thermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2889\" data-start=\"2833\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2859\" data-start=\"2833\"\u003eInsulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2889\" data-start=\"2859\"\u003e690 V (pollution degree 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2915\" data-start=\"2890\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2908\" data-start=\"2890\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-end=\"2915\" data-start=\"2908\" data-col-size=\"md\"\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2982\" data-start=\"2916\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2927\" data-start=\"2916\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2982\" data-start=\"2927\"\u003eFront mounting, front plate 45 × 45 mm, Multifixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3022\" data-start=\"2983\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2992\" data-start=\"2983\"\u003eHandle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3022\" data-start=\"2992\"\u003eBlack, 35 mm rotary handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3051\" data-start=\"3023\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3043\" data-start=\"3023\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-end=\"3051\" data-start=\"3043\" data-col-size=\"md\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3097\" data-start=\"3052\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3076\" data-start=\"3052\"\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3097\" data-start=\"3076\"\u003e~1,000,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3129\" data-start=\"3098\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3115\" data-start=\"3098\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3129\" data-start=\"3115\"\u003e-25…+55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3159\" data-start=\"3130\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3145\" data-start=\"3130\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3159\" data-start=\"3145\"\u003e-40…+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"3164\" data-start=\"3161\"\u003e\n\u003ch3 data-end=\"3188\" data-start=\"3166\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-end=\"3544\" data-start=\"3190\"\u003e\n\u003cli data-end=\"3277\" data-start=\"3190\"\u003e\n\u003cp data-end=\"3277\" data-start=\"3192\"\u003eSwitching between two power sources (changeover) or selecting alternate power lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3359\" data-start=\"3278\"\u003e\n\u003cp data-end=\"3359\" data-start=\"3280\"\u003eControl panels where a visible 3-position selector with OFF state is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3456\" data-start=\"3360\"\u003e\n\u003cp data-end=\"3456\" data-start=\"3362\"\u003eIndustrial machines, motor controls, or auxiliary circuits needing reliable ON-OFF switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3544\" data-start=\"3457\"\u003e\n\u003cp data-end=\"3544\" data-start=\"3459\"\u003eReplacing or upgrading old switches with modern ones conforming to IEC\/EN standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230567108891,"sku":"K2B001ULH","price":26.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2b001ulh-k2b001ulh-harmony-k_6147fa4c-3b06-440b-952c-9e491d2943b3.jpg?v=1777185538"},{"product_id":"schneider-electric-k2b002alh-cam-switch","title":"Schneider Electric K2B002ALH Harmony K K2 2-Pole 20A 45deg Cam Switch","description":"\u003cp\u003eThe Schneider Electric K2B002ALH is a Harmony K2 cam switch with two poles, a 45° switching angle, and a 20 A conventional free-air thermal current (Ith) — higher than the K1 frame in the same Harmony K range. It switches between an off position and one on position (0-1 marking) via a black handle with metallic legend, mounted to a front panel by multifixing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2B002ALH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.113 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K2B002ALH carries a 20 A Ith rating on the larger K2 frame, versus 12 A on the K1 cam switches in the same Harmony K range — pick it when the panel's pilot or small-power circuit exceeds the K1 frame's current rating but still needs the same 45 x 45 mm front-plate footprint. Its two-pole, on\/off function with a visible off position suits single-phase or DC circuit isolation rather than multi-step selection.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual on\/off disconnect on control-panel doors for two-pole pilot or small-power circuits that exceed the K1 frame's current rating, in machine-building and panel-shop assemblies.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230567272731,"sku":"K2B002ALH","price":19.53,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2b002alh-harmony-k2-cam-switch.jpg?v=1790287315"},{"product_id":"schneider-electric-k2c003alh-cam-switch","title":"Schneider Electric K2C003ALH Harmony K K2 3-Pole 20A 45deg Cam Switch","description":"\u003cp\u003eThe Schneider Electric K2C003ALH is a Harmony K2 cam switch with three poles, a 45° switching angle, and a 20 A conventional free-air thermal current (Ith). It switches all three poles together between an off position and one on position (0-1 marking), and mounts to a front panel by multifixing for three-phase disconnect or selector duty.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2C003ALH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2 (complete cam switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° - 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosed Thermal Current (Ithe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV (4 kV isolating function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A gG fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, 1x2.5 mm² solid \/ 2x1.5 mm² flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 20 A Ith on the K2 frame, the K2C003ALH handles a higher pilot or small three-phase load than the 12 A K1-frame switches in the same Harmony K range, while keeping the same 45° on\/off function and visible off position. CCC and GB\/T 14048.3\/14048.5 certification on this variant supports installations needing Chinese national approval. Choose the K1 frame instead when panel space is tighter and the circuit stays under 12 A.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a manual three-phase disconnect or selector switch on control-panel doors in machine-building and panel-shop assemblies where the load exceeds the K1 frame's current rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230567797019,"sku":"K2C003ALH","price":22.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2c003alh-harmony-k2-cam-switch.jpg?v=1790287322"},{"product_id":"schneider-electric-k2d002ulh-cam-changeover-switch","title":"Schneider Electric K2D002ULH Harmony K K2 20A 2P 45° Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K2D002ULH is a Harmony K2 cam changeover switch with two poles, a 45-degree switching angle, and a 20 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate, screw-clamp terminals, and a metallic 2-0-1 legend, it carries a 10 kA short-circuit withstand and an IP40 enclosure rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2D002ULH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft: 0 deg - 315 deg | Right: 0 deg - 45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2-pole changeover configuration is sized for the heavier-duty K2 body, 20 A Ith versus the K1's 12 A, suited to switching single-phase loads between two sources at 400 V. Choose the 3-pole or 4-pole K2 changeover versions for three-phase circuits, or the smaller K1 body where the 12 A rating is sufficient. Upstream protection is a 20 A gG cartridge fuse against the 10 kA short-circuit rating. The 45 x 45 mm front plate and metallic 2-0-1 legend keep the panel cutout and marking identical across the whole K2 changeover family regardless of pole count.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230568190235,"sku":"K2D002ULH","price":27.56,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2d002ulh-k2-cam-changeover-switch.jpg?v=1790284935"},{"product_id":"schneider-electric-k2f003ulh-cam-changeover-switch","title":"Schneider Electric K2F003ULH Harmony K K2 20A 3P 45° Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K2F003ULH is a Harmony K2 cam changeover switch with three poles, a 45-degree switching angle, and a 20 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate and screw-clamp terminals, it withstands a 10,000 A short-circuit current behind a 20 A gG fuse and carries an IP40 enclosure rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2F003ULH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight: 0 deg - 45 deg | Left: 0 deg - 315 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 97 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3-pole changeover configuration switches a three-phase circuit between two sources or motor rotation directions at up to 20 A Ith. Choose the 2-pole version for single-phase circuits or the 4-pole version when a neutral or fourth conductor must also be switched; all share the same K2 body and 45 x 45 mm front plate. The 10 kA short-circuit withstand is backed by a 20 A gG cartridge fuse upstream. Screw-clamp terminals accept flexible conductors up to 1.5 mm² or solid conductors up to 2.5 mm², matching the 2-pole and 4-pole K2 versions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230568812827,"sku":"K2F003ULH","price":34.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2f003ulh-k2-cam-changeover-switch.jpg?v=1790284942"},{"product_id":"schneider-electric-k2h004ulh-cam-changeover-switch","title":"Schneider Electric K2H004ULH Harmony K K2 20A 4P 45° Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K2H004ULH is a Harmony K2 cam changeover switch with four poles, a 45-degree switching angle, and a 20 A conventional free air thermal current (Ith). Front-mounted with a 45 x 45 mm plate and screw-clamp terminals, it withstands a 10,000 A short-circuit current behind a 20 A gG fuse and carries an IP40 enclosure rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2H004ULH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft: 0 deg - 315 deg | Right: 0 deg - 45 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, multifixing, 45 x 45 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 1.5 mm² flexible \/ 1 x 2.5 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 45 x 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCENELEC EN 50013\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4-pole changeover configuration switches all four conductors of a three-phase-plus-neutral circuit between two sources at up to 20 A Ith, where the 3-pole version would leave the neutral unswitched. It shares the K2 body, 45 x 45 mm front plate, and 20 A gG fuse back-up with the 2-pole and 3-pole changeover variants, differing only in depth, 107 mm, to fit the extra pole. Screw-clamp terminals accept flexible conductors up to 1.5 mm² or solid conductors up to 2.5 mm² on every pole.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230569632027,"sku":"K2H004ULH","price":40.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k2h004ulh-k2-cam-changeover-switch.jpg?v=1790284949"},{"product_id":"schneider-electric-k30b001up-harmony-k","title":"Schneider Electric K30B001UP Harmony K","description":"\u003cp data-start=\"212\" data-end=\"489\"\u003eThe \u003cstrong data-start=\"216\" data-end=\"248\"\u003eSchneider Electric K30B001UP\u003c\/strong\u003e is a robust front-mount cam change-over switch from the Harmony K line. Designed for reliable ON\/OFF or changeover control in industrial panel applications, it delivers high current capacity, multiple positions, and standardized mounting.\u003c\/p\u003e\n\u003chr data-start=\"491\" data-end=\"494\"\u003e\n\u003ch3 data-start=\"496\" data-end=\"523\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"525\" data-end=\"2193\"\u003e\n\u003cli data-start=\"525\" data-end=\"703\"\u003e\n\u003cp data-start=\"527\" data-end=\"703\"\u003e\u003cstrong data-start=\"527\" data-end=\"563\"\u003e1-Pole, 2-Position (SPST) Switch\u003c\/strong\u003e\u003cbr data-start=\"563\" data-end=\"566\"\u003eProvides two switching positions (marked “1 \/ 0 \/ 2”) for changeover operation with an OFF state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"705\" data-end=\"861\"\u003e\n\u003cp data-start=\"707\" data-end=\"861\"\u003e\u003cstrong data-start=\"707\" data-end=\"730\"\u003eRated Current: 32 A\u003c\/strong\u003e\u003cbr data-start=\"730\" data-end=\"733\"\u003eSupports 32 A conventional free-air thermal current, suitable for many industrial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"863\" data-end=\"1058\"\u003e\n\u003cp data-start=\"865\" data-end=\"1058\"\u003e\u003cstrong data-start=\"865\" data-end=\"899\"\u003eSwitching Angle \u0026amp; OFF Position\u003c\/strong\u003e\u003cbr data-start=\"899\" data-end=\"902\"\u003eThe switching angle is 60°, with an OFF position included. This allows safe “no contact” position between ON states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1060\" data-end=\"1265\"\u003e\n\u003cp data-start=\"1062\" data-end=\"1265\"\u003e\u003cstrong data-start=\"1062\" data-end=\"1108\"\u003eStandard Front-Mount with 64 × 64 mm Plate\u003c\/strong\u003e\u003cbr data-start=\"1108\" data-end=\"1111\"\u003eDesigned to mount from the front using a 64 mm × 64 mm plate with four mounting holes—fits standard panel cutouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1267\" data-end=\"1422\"\u003e\n\u003cp data-start=\"1269\" data-end=\"1422\"\u003e\u003cstrong data-start=\"1269\" data-end=\"1305\"\u003ePlastic Enclosure \u0026amp; Black Handle\u003c\/strong\u003e\u003cbr data-start=\"1305\" data-end=\"1308\"\u003eDurable plastic body with black rotary handle and metallic legend “1-0-2”.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1424\" data-end=\"1698\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1455\"\u003e\u003cstrong data-start=\"1426\" data-end=\"1453\"\u003eProtection \u0026amp; Durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1460\" data-end=\"1698\"\u003e\n\u003cli data-start=\"1460\" data-end=\"1593\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1593\"\u003eIP40 protection at the front (basic protection against solid objects, no water resistance).\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1698\"\u003e\n\u003cp data-start=\"1600\" data-end=\"1698\"\u003eMechanical life: ~300,000 cycles — built for long service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1870\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1870\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1736\"\u003eVoltage \u0026amp; Standards Compliance\u003c\/strong\u003e\u003cbr data-start=\"1736\" data-end=\"1739\"\u003eRated insulation voltage up to 690 V per IEC\/EN 60947-1 standards. Slow-break contact type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1872\" data-end=\"2054\"\u003e\n\u003cp data-start=\"1874\" data-end=\"2054\"\u003e\u003cstrong data-start=\"1874\" data-end=\"1903\"\u003eTerminal \u0026amp; Handle Details\u003c\/strong\u003e\u003cbr data-start=\"1903\" data-end=\"1906\"\u003eUses captive screw clamp terminals (flexible ~2×4 mm²; solid ~2×6 mm²). Tightening torque approx. 1.2 N·m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2056\" data-end=\"2193\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2193\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2093\"\u003eOperating \u0026amp; Storage Temperature\u003c\/strong\u003e\u003cbr data-start=\"2093\" data-end=\"2096\"\u003eOperation: −25 °C to +55 °C. Storage: −40 °C to +70 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2195\" data-end=\"2198\"\u003e\n\u003ch3 data-start=\"2200\" data-end=\"2224\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2226\" data-end=\"2519\"\u003e\n\u003cli data-start=\"2226\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2228\" data-end=\"2297\"\u003eON\/OFF or changeover switching in control panels and motor circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2298\" data-end=\"2378\"\u003e\n\u003cp data-start=\"2300\" data-end=\"2378\"\u003eIndustrial machinery power isolation where a durable rotary switch is needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2379\" data-end=\"2450\"\u003e\n\u003cp data-start=\"2381\" data-end=\"2450\"\u003eReplacement of older selector \/ cam switches in industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2451\" data-end=\"2519\"\u003e\n\u003cp data-start=\"2453\" data-end=\"2519\"\u003ePanels where space and standard mounting format (64×64) are used\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230572777755,"sku":"K30B001UP","price":85.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k30b001up-k30b001up-harmony-k_ccb08405-60ab-4f99-82a5-34cccca03e2f.jpg?v=1777185543"},{"product_id":"schneider-electric-k30c003ap-harmony-k","title":"Schneider Electric K30C003AP Harmony K","description":"\u003cp data-start=\"185\" data-end=\"485\"\u003eUpgrade electrical control in panels, machines, or industrial equipment with the \u003cstrong data-start=\"266\" data-end=\"309\"\u003eSchneider Electric K30C003AP cam switch\u003c\/strong\u003e, part of the durable Harmony K series. This rotary switch is designed for reliable ON\/OFF operation under demanding conditions, with robust current capacity and clear marking.\u003c\/p\u003e\n\u003chr data-start=\"487\" data-end=\"490\"\u003e\n\u003ch3 data-start=\"492\" data-end=\"519\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"521\" data-end=\"1911\"\u003e\n\u003cli data-start=\"521\" data-end=\"722\"\u003e\n\u003cp data-start=\"523\" data-end=\"722\"\u003e\u003cstrong data-start=\"523\" data-end=\"559\"\u003e3-Pole, 2-Position ON\/OFF Switch\u003c\/strong\u003e\u003cbr data-start=\"559\" data-end=\"562\"\u003eOffers two stable positions (“0-1”) with a 60° switching angle, allowing controlled switching between OFF and ON states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"724\" data-end=\"897\"\u003e\n\u003cp data-start=\"726\" data-end=\"897\"\u003e\u003cstrong data-start=\"726\" data-end=\"749\"\u003e32 A Current Rating\u003c\/strong\u003e\u003cbr data-start=\"749\" data-end=\"752\"\u003eSupports up to 32 A conventional free-air thermal current—suitable for many industrial load applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"1062\"\u003e\n\u003cp data-start=\"901\" data-end=\"1062\"\u003e\u003cstrong data-start=\"901\" data-end=\"947\"\u003eFront Mounting with 64 × 64 mm Front Plate\u003c\/strong\u003e\u003cbr data-start=\"947\" data-end=\"950\"\u003eDesigned to mount on panels using a 64 × 64 mm front plate with 4 holes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1258\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1258\"\u003e\u003cstrong data-start=\"1066\" data-end=\"1106\"\u003eMarked Legend (“0-1”) \u0026amp; Black Handle\u003c\/strong\u003e\u003cbr data-start=\"1106\" data-end=\"1109\"\u003eClearly labeled with metallic legend “0-1” and includes a black rotary handle for easy visual identification.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1260\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1262\" data-end=\"1478\"\u003e\u003cstrong data-start=\"1262\" data-end=\"1301\"\u003eInsulation \u0026amp; Voltage Specifications\u003c\/strong\u003e\u003cbr data-start=\"1301\" data-end=\"1304\"\u003eRated insulation voltage up to ~690 V, pollution degree 3. Provides protection against overvoltage and meets IEC\/EN 60947-1 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1715\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1715\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1510\"\u003eConstruction \u0026amp; Terminals\u003c\/strong\u003e\u003cbr data-start=\"1510\" data-end=\"1513\"\u003eUses screw mounting, captive screw clamp terminals: accommodates flexible conductors (≈ 2 × 4 mm²) and solid conductors (≈ 2 × 6 mm²). Tightening torque ~1.2 N·m.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1717\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1719\" data-end=\"1911\"\u003e\u003cstrong data-start=\"1719\" data-end=\"1732\"\u003eIP Rating\u003c\/strong\u003e\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eFront protection is IP40—good for basic protection against dust and contact but not suited for exposure to water jets or heavy moisture.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1913\" data-end=\"1916\"\u003e\n\u003ch3 data-start=\"1918\" data-end=\"1946\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1948\" data-end=\"2616\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1948\" data-end=\"1973\"\u003e\n\u003ctr data-start=\"1948\" data-end=\"1973\"\u003e\n\u003cth data-start=\"1948\" data-end=\"1964\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1964\" data-end=\"1973\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2034\" data-end=\"2616\"\u003e\n\u003ctr data-start=\"2034\" data-end=\"2071\"\u003e\n\u003ctd data-start=\"2034\" data-end=\"2042\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2042\" data-end=\"2071\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"2044\" data-end=\"2057\"\u003eK30C003AP\u003c\/strong\u003e (Harmony K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2072\" data-end=\"2100\"\u003e\n\u003ctd data-start=\"2072\" data-end=\"2080\" data-col-size=\"sm\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-start=\"2080\" data-end=\"2100\" data-col-size=\"md\"\u003e3P (three poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2101\" data-end=\"2137\"\u003e\n\u003ctd data-start=\"2101\" data-end=\"2113\" data-col-size=\"sm\"\u003ePositions\u003c\/td\u003e\n\u003ctd data-start=\"2113\" data-end=\"2137\" data-col-size=\"md\"\u003e2 (OFF “0” \/ ON “1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2138\" data-end=\"2163\"\u003e\n\u003ctd data-start=\"2138\" data-end=\"2156\" data-col-size=\"sm\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-start=\"2156\" data-end=\"2163\" data-col-size=\"md\"\u003e60°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2164\" data-end=\"2208\"\u003e\n\u003ctd data-start=\"2164\" data-end=\"2181\" data-col-size=\"sm\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd data-start=\"2181\" data-end=\"2208\" data-col-size=\"md\"\u003e32 A (free-air thermal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2209\" data-end=\"2246\"\u003e\n\u003ctd data-start=\"2209\" data-end=\"2236\" data-col-size=\"sm\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2236\" data-end=\"2246\" data-col-size=\"md\"\u003e~690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2247\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2247\" data-end=\"2266\" data-col-size=\"sm\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd data-start=\"2266\" data-end=\"2271\" data-col-size=\"md\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2304\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2295\" data-col-size=\"sm\"\u003eHead \/ Handle Colour\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2295\" data-end=\"2304\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2305\" data-end=\"2340\"\u003e\n\u003ctd data-start=\"2305\" data-end=\"2315\" data-col-size=\"sm\"\u003eMarking\u003c\/td\u003e\n\u003ctd data-start=\"2315\" data-end=\"2340\" data-col-size=\"md\"\u003eMetallic legend \"0-1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2341\" data-end=\"2408\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2358\" data-col-size=\"sm\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-start=\"2358\" data-end=\"2408\" data-col-size=\"md\"\u003eFront mounting, 4-hole front plate, 64 × 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2409\" data-end=\"2466\"\u003e\n\u003ctd data-start=\"2409\" data-end=\"2429\" data-col-size=\"sm\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2429\" data-end=\"2466\"\u003eFlexible ~2×4 mm², Solid ~2×6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2467\" data-end=\"2499\"\u003e\n\u003ctd data-start=\"2467\" data-end=\"2487\" data-col-size=\"sm\"\u003eTightening Torque\u003c\/td\u003e\n\u003ctd data-start=\"2487\" data-end=\"2499\" data-col-size=\"md\"\u003e~1.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2500\" data-end=\"2529\"\u003e\n\u003ctd data-start=\"2500\" data-end=\"2521\" data-col-size=\"sm\"\u003eProtection (Front)\u003c\/td\u003e\n\u003ctd data-start=\"2521\" data-end=\"2529\" data-col-size=\"md\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2530\" data-end=\"2616\"\u003e\n\u003ctd data-start=\"2530\" data-end=\"2542\" data-col-size=\"sm\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2616\" data-col-size=\"md\"\u003eEN\/IEC 60947-1 and related norms\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2618\" data-end=\"2621\"\u003e\n\u003ch3 data-start=\"2623\" data-end=\"2645\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"2647\" data-end=\"2999\"\u003e\n\u003cli data-start=\"2647\" data-end=\"2750\"\u003e\n\u003cp data-start=\"2649\" data-end=\"2750\"\u003eON\/OFF control in industrial power panels or motor starters where a compact rotary switch is needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2751\" data-end=\"2814\"\u003e\n\u003cp data-start=\"2753\" data-end=\"2814\"\u003eMachinery requiring clear, simple selector control of power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2815\" data-end=\"2896\"\u003e\n\u003cp data-start=\"2817\" data-end=\"2896\"\u003eReplacement or upgrade of existing cam or rotary switches in control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2897\" data-end=\"2999\"\u003e\n\u003cp data-start=\"2899\" data-end=\"2999\"\u003eEnvironments where high current switching is needed, but exposure to moisture or splash is minimal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230572908827,"sku":"K30C003AP","price":107.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k30c003ap-k30c003ap-harmony-k_2931e12a-a7d3-4346-befb-6d978acef7ec.jpg?v=1777185547"},{"product_id":"schneider-electric-k30d002up-harmony-k-cam-switch","title":"Schneider Electric K30D002UP Harmony K K30 2-Pole 32A Front Mount Cam Switch","description":"\u003cp\u003eThe Schneider Electric K30D002UP is a Harmony K series front-mounted cam changeover switch with 2 poles, rated for 32 A conventional free-air thermal current (Ith) and 690 V insulation voltage (Ui). The 64 x 64 mm plastic front plate carries a black handle marked 1-0-2, switching 60 degrees between two positions with an off position in the center, IP40 rated.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK30D002UP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110083330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Free Air Thermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A cartridge fuse gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-0-2 marked, with off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, 4 holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Head Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront plate 64 x 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Operator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, flexible 2 x 4 mm2 \/ solid 2 x 6 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 64 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II (IEC 60536)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2-pole configuration suits circuits where only two conductors need to switch between sources, such as single-phase changeover or switching one motor winding pair between two supplies. With a 32 A Ith rating and 690 V Ui, it covers general-purpose motor and lighting changeover duty inside enclosed panels; the 3-pole version exists for full three-phase changeover where all three line conductors must switch together. Pick the 2P body when a leg or neutral stays common between the two switched sources.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTypical uses include changeover between two single-phase supplies, switching a control circuit between manual and automatic operating mode, or alternating a two-wire load between main and standby feed. The captive screw clamp terminals accept 2 x 4 mm2 flexible or 2 x 6 mm2 solid conductors, so panel wiring does not need ferrules. The 4-hole front mounting and 64 x 64 mm cutout match the standard Harmony K panel footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230573760795,"sku":"K30D002UP","price":94.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k30d002up-k30-cam-switch.jpg?v=1790287774"},{"product_id":"schneider-electric-k30f003up-harmony-k-cam-switch","title":"Schneider Electric K30F003UP Harmony K K30 3-Pole 32A Front Mount Cam Switch","description":"\u003cp\u003eThe Schneider Electric K30F003UP is a Harmony K series front-mounted cam changeover switch with 3 poles, rated for 32 A conventional free-air thermal current (Ith) and 690 V insulation voltage (Ui). The 64 x 64 mm plastic front plate carries a black handle marked 1-0-2, switching 60 degrees between two positions with an off position in the center, IP40 rated.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK30F003UP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110083354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional Free Air Thermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A cartridge fuse gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-0-2 marked, with off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, 4 holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam Switch Head Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront plate 64 x 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Operator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, flexible 2 x 4 mm2 \/ solid 2 x 6 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 64 x 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.425 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II (IEC 60536)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3-pole configuration switches all three line conductors together, which is what three-phase changeover duty requires - for example alternating a three-phase load between mains and generator, or selecting between two three-phase feeders. With 32 A Ith and 690 V Ui it covers general-purpose three-phase motor and distribution changeover in enclosed panels; the 2-pole version exists for circuits where only two conductors need to switch. Pick the 3P body whenever the load is three-phase and all three lines must transfer at once.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTypical uses include transferring a three-phase motor or distribution board between mains and generator supply, or selecting between two three-phase feeders in a dual-source panel. The captive screw clamp terminals accept 2 x 4 mm2 flexible or 2 x 6 mm2 solid conductors, so panel wiring does not need ferrules. The 4-hole front mounting and 64 x 64 mm cutout match the standard Harmony K panel footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230574612763,"sku":"K30F003UP","price":120.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k30f003up-k30-cam-switch.jpg?v=1790287781"},{"product_id":"schneider-electric-k50f003up-harmony-k-cam-changeover-switch","title":"Schneider Electric K50F003UP Harmony K K50 3-Pole 50A Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K50F003UP is a Harmony K front-mounted cam changeover switch rated 50 A, built for 3-pole 0-1-2 position control at up to 690 V insulation voltage. Its 64 x 64 mm front plate mounts with 4 holes, and the black rotary handle switches between 0° and 60° on the right or 0° and 300° on the left, with a metallic 1-0-2 legend marking each position.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eK50F003UP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Name\u003c\/td\u003e\n\u003ctd\u003eK50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110083361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eComplete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCam Switch Function\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Positions\u003c\/td\u003e\n\u003ctd\u003eRight: 0°-60°, Left: 0°-300°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff Position\u003c\/td\u003e\n\u003ctd\u003eWith off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixing Mode\u003c\/td\u003e\n\u003ctd\u003e4 holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Plate\u003c\/td\u003e\n\u003ctd\u003e64 x 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e63 A gG cartridge fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, flexible 2 x 6 mm² \/ solid 2 x 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25...55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe off position gives a true 3-pole isolating function between the two switching positions, which sets a changeover cam switch apart from a simple selector: with Off at the center of the 1-0-2 sequence, the load is fully disconnected before the operator reverses direction or switches source. The 5000 A short-circuit rating, backed by a 63 A gG fuse ahead of it, lets it sit directly on a feeder without a separate isolator. The 690 V insulation rating and Class II overvoltage category are why this frame suits panels built to a higher insulation margin than a standard 400 V motor circuit needs. Front mounting with a 64 x 64 mm plate and 4-hole fixing keeps the footprint compact on a control panel door.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230575399195,"sku":"K50F003UP","price":178.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k50f003up-harmony-k-cam-switch.jpg?v=1790282078"},{"product_id":"schneider-electric-k63c003ap-harmony-series-k","title":"Schneider Electric K63C003AP Harmony Series K","description":"\u003cp data-start=\"223\" data-end=\"507\"\u003eControl power safely and reliably with the \u003cstrong data-start=\"266\" data-end=\"298\"\u003eSchneider Electric K63C003AP\u003c\/strong\u003e cam switch from the Harmony K product line. Designed for industrial panels and machinery, this 3-pole switch handles high current loads, provides robust insulation, and is engineered for long-term durability.\u003c\/p\u003e\n\u003chr data-start=\"509\" data-end=\"512\"\u003e\n\u003ch3 data-start=\"514\" data-end=\"541\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"543\" data-end=\"2440\"\u003e\n\u003cli data-start=\"543\" data-end=\"755\"\u003e\n\u003cp data-start=\"545\" data-end=\"755\"\u003e\u003cstrong data-start=\"545\" data-end=\"590\"\u003eHigh Current Rating (63 A, 3-Pole Switch)\u003c\/strong\u003e\u003cbr data-start=\"590\" data-end=\"593\"\u003eRated for 63 A of conventional free-air thermal current, across 3 poles. Ideal for mains power control and load switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"757\" data-end=\"990\"\u003e\n\u003cp data-start=\"759\" data-end=\"990\"\u003e\u003cstrong data-start=\"759\" data-end=\"806\"\u003eFront-Mounting Design with 64 × 64 mm Plate\u003c\/strong\u003e\u003cbr data-start=\"806\" data-end=\"809\"\u003eMounts from the front using a 64 × 64 mm plate (4 holes) for solid panel integration. Black rotary handle provides “0-1” switching positions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1211\"\u003e\n\u003cp data-start=\"994\" data-end=\"1211\"\u003e\u003cstrong data-start=\"994\" data-end=\"1034\"\u003eRated Insulation Voltage up to 690 V\u003c\/strong\u003e\u003cbr data-start=\"1034\" data-end=\"1037\"\u003eInsulation and operational voltage standards comply with IEC\/EN 60947-1; suitable for use in three-phase and industrial power systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1384\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1384\"\u003e\u003cstrong data-start=\"1215\" data-end=\"1246\"\u003eSwitching Positions \u0026amp; Angle\u003c\/strong\u003e\u003cbr data-start=\"1246\" data-end=\"1249\"\u003eTwo positions: OFF (“0”) and ON (“1”), with a switching angle of 60°, enabling precise control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1386\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1388\" data-end=\"1630\"\u003e\u003cstrong data-start=\"1388\" data-end=\"1435\"\u003eSlow-Break Contacts \u0026amp; Robust Power Capacity\u003c\/strong\u003e\u003cbr data-start=\"1435\" data-end=\"1438\"\u003eSwitch handles AC-3 and AC-23A duty, with operational power up to ~18.5 kW for 3-phase systems. This switch is built to break current safely under load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1912\"\u003e\n\u003cp data-start=\"1634\" data-end=\"1715\"\u003e\u003cstrong data-start=\"1634\" data-end=\"1673\"\u003eDurable Construction \u0026amp; Terminations\u003c\/strong\u003e\u003cbr data-start=\"1673\" data-end=\"1676\"\u003eUses captive screw clamp terminals:\u003c\/p\u003e\n\u003cul data-start=\"1718\" data-end=\"1912\"\u003e\n\u003cli data-start=\"1718\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1720\" data-end=\"1753\"\u003eFlexible conductors: 2 × 10 mm²\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1756\" data-end=\"1912\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1912\"\u003eSolid conductors: 2 × 16 mm²\u003cbr data-start=\"1824\" data-end=\"1827\"\u003eAlso positive opening of contacts for safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"2148\"\u003e\n\u003cp data-start=\"1916\" data-end=\"2148\"\u003e\u003cstrong data-start=\"1916\" data-end=\"1946\"\u003eModerate Protection Rating\u003c\/strong\u003e\u003cbr data-start=\"1946\" data-end=\"1949\"\u003eIP40 protection for the enclosure—suitable in environments where solid objects and limited ingress are concerns, but not for water or dust-sealed applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2150\" data-end=\"2301\"\u003e\n\u003cp data-start=\"2152\" data-end=\"2301\"\u003e\u003cstrong data-start=\"2152\" data-end=\"2177\"\u003eMechanical Durability\u003c\/strong\u003e\u003cbr data-start=\"2177\" data-end=\"2180\"\u003eRated for \u003cstrong data-start=\"2192\" data-end=\"2223\"\u003e≈ 300,000 mechanical cycles\u003c\/strong\u003e, ensuring long life under repeated use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2303\" data-end=\"2440\"\u003e\n\u003cp data-start=\"2305\" data-end=\"2440\"\u003e\u003cstrong data-start=\"2305\" data-end=\"2336\"\u003eOperating Temperature Range\u003c\/strong\u003e\u003cbr data-start=\"2336\" data-end=\"2339\"\u003e-25 °C to +55 °C in operation; storage from -40 °C to +70 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2442\" data-end=\"2445\"\u003e\n\u003ch3 data-start=\"2447\" data-end=\"2487\"\u003eTechnical Specifications at a Glance\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2489\" data-end=\"3174\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2489\" data-end=\"2514\"\u003e\n\u003ctr data-start=\"2489\" data-end=\"2514\"\u003e\n\u003cth data-start=\"2489\" data-end=\"2505\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2505\" data-end=\"2514\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2529\" data-end=\"3174\"\u003e\n\u003ctr data-start=\"2529\" data-end=\"2572\"\u003e\n\u003ctd data-start=\"2529\" data-end=\"2537\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2537\" data-end=\"2572\"\u003e\n\u003cstrong data-start=\"2539\" data-end=\"2552\"\u003eK63C003AP\u003c\/strong\u003e, Harmony K Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2573\" data-end=\"2611\"\u003e\n\u003ctd data-start=\"2573\" data-end=\"2591\" data-col-size=\"sm\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd data-start=\"2591\" data-end=\"2611\" data-col-size=\"md\"\u003e3P (three poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2612\" data-end=\"2661\"\u003e\n\u003ctd data-start=\"2612\" data-end=\"2634\" data-col-size=\"sm\"\u003eRated Current (Ith)\u003c\/td\u003e\n\u003ctd data-start=\"2634\" data-end=\"2661\" data-col-size=\"md\"\u003e63 A (free air thermal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2662\" data-end=\"2703\"\u003e\n\u003ctd data-start=\"2662\" data-end=\"2694\" data-col-size=\"sm\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2694\" data-end=\"2703\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2704\" data-end=\"2769\"\u003e\n\u003ctd data-start=\"2704\" data-end=\"2723\" data-col-size=\"sm\"\u003eSwitching Rating\u003c\/td\u003e\n\u003ctd data-start=\"2723\" data-end=\"2769\" data-col-size=\"md\"\u003eAC-3, AC-23A, various voltages up to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2770\" data-end=\"2812\"\u003e\n\u003ctd data-start=\"2770\" data-end=\"2792\" data-col-size=\"sm\"\u003eSwitching Positions\u003c\/td\u003e\n\u003ctd data-start=\"2792\" data-end=\"2812\" data-col-size=\"md\"\u003eOFF “0” \/ ON “1”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2813\" data-end=\"2838\"\u003e\n\u003ctd data-start=\"2813\" data-end=\"2831\" data-col-size=\"sm\"\u003eSwitching Angle\u003c\/td\u003e\n\u003ctd data-start=\"2831\" data-end=\"2838\" data-col-size=\"md\"\u003e60°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2839\" data-end=\"2866\"\u003e\n\u003ctd data-start=\"2839\" data-end=\"2858\" data-col-size=\"sm\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd data-start=\"2858\" data-end=\"2866\" data-col-size=\"md\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2867\" data-end=\"2952\"\u003e\n\u003ctd data-start=\"2867\" data-end=\"2894\" data-col-size=\"sm\"\u003eTerminal Type \u0026amp; Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2894\" data-end=\"2952\" data-col-size=\"md\"\u003eCaptive screw clamp: flexible 2×10 mm², solid 2×16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2953\" data-end=\"2990\"\u003e\n\u003ctd data-start=\"2953\" data-end=\"2971\" data-col-size=\"sm\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd data-start=\"2971\" data-end=\"2990\" data-col-size=\"md\"\u003e~300,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2991\" data-end=\"3023\"\u003e\n\u003ctd data-start=\"2991\" data-end=\"3009\" data-col-size=\"sm\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd data-start=\"3009\" data-end=\"3023\" data-col-size=\"md\"\u003e-25…+55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3024\" data-end=\"3054\"\u003e\n\u003ctd data-start=\"3024\" data-end=\"3040\" data-col-size=\"sm\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd data-start=\"3040\" data-end=\"3054\" data-col-size=\"md\"\u003e-40…+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3055\" data-end=\"3174\"\u003e\n\u003ctd data-start=\"3055\" data-end=\"3082\" data-col-size=\"sm\"\u003eDimensions (Front Plate)\u003c\/td\u003e\n\u003ctd data-start=\"3082\" data-end=\"3174\" data-col-size=\"md\"\u003e64 x 64 mm mounting plate; overall depth ~111 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3176\" data-end=\"3179\"\u003e\n\u003ch3 data-start=\"3181\" data-end=\"3203\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"3205\" data-end=\"3538\"\u003e\n\u003cli data-start=\"3205\" data-end=\"3307\"\u003e\n\u003cp data-start=\"3207\" data-end=\"3307\"\u003eOn-\/Off control for industrial loads (motors, heaters) where a simple, reliable switch is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3308\" data-end=\"3408\"\u003e\n\u003cp data-start=\"3310\" data-end=\"3408\"\u003ePanel-mounted control switch in machine control, automation panels, or power distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3409\" data-end=\"3538\"\u003e\n\u003cp data-start=\"3411\" data-end=\"3538\"\u003eReplacement of aging or failed switches in power circuits limited to protected environments (not exposed to water\/dust ingress)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230575661339,"sku":"K63C003AP","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k63c003ap-harmony-series-k_9f0944ce-3bc5-43f5-ab36-e9d56f9a0acc.jpg?v=1777185551"},{"product_id":"schneider-electric-k63f003up-cam-changeover-switch","title":"Schneider Electric K63F003UP Harmony K K63 63A 3P 60° Cam Changeover Switch","description":"\u003cp\u003eThe Schneider Electric K63F003UP is a Harmony K63 cam changeover switch with three poles, a 60-degree switching angle, and a 63 A conventional free air thermal current (Ith). Front-mounted with a 64 x 64 mm plate and screw-clamp terminals rated to 16 mm², it withstands a 10,000 A short-circuit current behind an 80 A gG fuse within an IP40 enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK63F003UP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110083378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCam switch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight: 0 deg - 60 deg | Left: 0 deg - 300 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V, pollution degree 3, IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV, EN\/IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront, 4-hole fixing, 64 x 64 mm front plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 2 x 10 mm² flexible \/ 2 x 16 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 64 x 132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eIEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe K63 body steps up to 63 A Ith with a 60-degree switching angle and a larger 64 x 64 mm front plate, sized for direct three-phase motor switching or changeover duty well beyond the 20 A K2 range. Screw-clamp terminals accept conductors up to 16 mm² solid, and the 10 kA short-circuit rating is backed by an 80 A gG cartridge fuse upstream. Choose the K1 or K2 body instead for control-circuit or light three-phase switching where 12-20 A is sufficient.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230575956251,"sku":"K63F003UP","price":202.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-k63f003up-k63-cam-changeover-switch.jpg?v=1790284958"}],"url":"https:\/\/stoklink.com\/en-sa\/collections\/cam-switch.oembed","provider":"Stoklink","version":"1.0","type":"link"}