{"title":"VFD Accessories (Power Modules, Reactors, Panels)","description":"\u003cp\u003eVFD accessories from Siemens, ABB and Schneider Electric include power modules, reactors, filters, operator panels and option modules. The range spans 0.55 kW to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request. Check the type code of your drive before ordering.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSiemens SINAMICS power modules such as PM240-2, G120 and G130 modules for modular drive systems.\u003c\/li\u003e\n\u003cli\u003eLine reactors and du\/dt filters, including SINAMICS S120 reactors and FOCH filters.\u003c\/li\u003e\n\u003cli\u003eABB assistant panels and flange kits.\u003c\/li\u003e\n\u003cli\u003eSchneider Altivar display terminals and interface modules, such as resolver interface cards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMatch the part to the exact drive family and frame size. Accessories are rarely interchangeable.\u003c\/li\u003e\n\u003cli\u003ePower module rating must match the control unit and motor.\u003c\/li\u003e\n\u003cli\u003eFilters and reactors: select by drive current and cable length.\u003c\/li\u003e\n\u003cli\u003eOption modules: check the fieldbus or encoder type needed.\u003c\/li\u003e\n\u003cli\u003eRated current and voltage class of the drive the part will serve.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does a power module do?\u003c\/h3\u003e\u003cp\u003eIn modular drives, the power module holds the inverter section. The control unit is separate and plugs onto it.\u003c\/p\u003e\u003ch3\u003eWhen do I need a du\/dt filter?\u003c\/h3\u003e\u003cp\u003eUse one with long motor cables or older motors, to limit voltage rise that stresses winding insulation.\u003c\/p\u003e\u003ch3\u003eDo you ship drive accessories outside Turkey?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"siemens-6sl3255-0aa00-4ca1-sinamics-g120-bop-2-basic-operator-panel","title":"Siemens 6SL3255-0AA00-4CA1 SINAMICS G120 BOP-2 Basic Operator Panel","description":"\u003cp\u003eThe Siemens 6SL3255-0AA00-4CA1 is the BOP-2 basic operator panel for SINAMICS G120 frequency converters. It snaps directly onto the control unit and provides a two-line display with menu-based navigation for commissioning, parameterization, monitoring and diagnostics of the drive — no PC or software required.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3255-0AA00-4CA1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic Operator Panel (BOP-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-line, menu-based\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 control units (CU230P-2, CU240B-2, CU240E-2, CU250S-2), G120C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSnap-on (drive front)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eUsed for local commissioning and operation of SINAMICS G120 family drives: set parameters, copy parameter sets between drives, monitor actual values and read out fault diagnostics directly at the cabinet. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631447994651,"sku":"6SL3255-0AA00-4CA1","price":31.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3255-0aa00-4ca1.webp?v=1784565557"},{"product_id":"siemens-6sl3210-1pe31-8ul0-sinamics-g120-pm240-2-power-module-90kw-400v-3ac","title":"Siemens 6SL3210-1PE31-8UL0 SINAMICS G120 PM240-2 Power Module 90kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE31-8UL0 is a SINAMICS G120 PM240-2 power module rated 90 kW for 380-480 V 3 AC supply. It delivers 172 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE31-8UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e172.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnfiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 708 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n  \u003cli\u003eSEMI F47\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE31-8UL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631448486171,"sku":"6SL3210-1PE31-8UL0","price":5358.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe31-8ul0.webp?v=1784565566"},{"product_id":"siemens-6sl3210-1pe32-1ul0-sinamics-g120-pm240-2-power-module-110kw-400v-3ac","title":"Siemens 6SL3210-1PE32-1UL0 SINAMICS G120 PM240-2 Power Module 110kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE32-1UL0 is a SINAMICS G120 PM240-2 power module rated 110 kW for 380-480 V 3 AC supply. It delivers 198 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE32-1UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e356.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnfiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 708 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n  \u003cli\u003eSEMI F47\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE32-1UL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631448551707,"sku":"6SL3210-1PE32-1UL0","price":6052.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe32-1ul0.webp?v=1784565573"},{"product_id":"siemens-6sl3210-1pe32-5ul0-sinamics-g120-pm240-2-power-module-132kw-400v-3ac","title":"Siemens 6SL3210-1PE32-5UL0 SINAMICS G120 PM240-2 Power Module 132kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE32-5UL0 is a SINAMICS G120 PM240-2 power module rated 132 kW for 380-480 V 3 AC supply. It delivers 242 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE32-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e242.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnfiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 708 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n  \u003cli\u003eSEMI F47\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE32-5UL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631448682779,"sku":"6SL3210-1PE32-5UL0","price":6746.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe32-5ul0.webp?v=1784565582"},{"product_id":"siemens-6sl3210-1pe33-0cl0-sinamics-g120-pm240-2-power-module-160kw-400v-3ac","title":"Siemens 6SL3210-1PE33-0CL0 SINAMICS G120 PM240-2 Power Module 160kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE33-0CL0 is a SINAMICS G120 PM240-2 power module rated 160 kW for 380-480 V 3 AC supply. It delivers 300 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE33-0CL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSG\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 1,000 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE33-0CL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631448781083,"sku":"6SL3210-1PE33-0CL0","price":8172.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe33-0cl0.webp?v=1784565589"},{"product_id":"siemens-6sl3210-1pe33-7cl0-sinamics-g120-pm240-2-power-module-200kw-400v-3ac","title":"Siemens 6SL3210-1PE33-7CL0 SINAMICS G120 PM240-2 Power Module 200kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE33-7CL0 is a SINAMICS G120 PM240-2 power module rated 200 kW for 380-480 V 3 AC supply. It delivers 365 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE33-7CL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e365.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e604.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSG\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 1,000 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE33-7CL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631448846619,"sku":"6SL3210-1PE33-7CL0","price":9541.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe33-7cl0.webp?v=1784565596"},{"product_id":"siemens-6sl3210-1pe34-8cl0-sinamics-g120-pm240-2-power-module-250kw-400v-3ac","title":"Siemens 6SL3210-1PE34-8CL0 SINAMICS G120 PM240-2 Power Module 250kW 400V 3AC","description":"\u003cp\u003eThe Siemens 6SL3210-1PE34-8CL0 is a SINAMICS G120 PM240-2 power module rated 250 kW for 380-480 V 3 AC supply. It delivers 470 A rated output current with vector control when combined with a CU240E-2 control unit, integrated braking chopper, and IP20 \/ UL open type protection for control-cabinet mounting.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE34-8CL0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e740.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSG\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm × 1,000 mm × 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC61800-9\u003c\/li\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eC-Tick (RCM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 6SL3210-1PE34-8CL0 is designed for modular SINAMICS G120 drive systems: paired with a CU240E-2\/CU250S-2 control unit it forms a complete frequency converter for pumps, fans, conveyors and industrial machinery in the higher power range.\u003c\/p\u003e\n\u003cp\u003eGenuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52631449075995,"sku":"6SL3210-1PE34-8CL0","price":11025.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe34-8cl0.webp?v=1784565603"},{"product_id":"siemens-6sl3054-4ag00-2aa0-sinamics-sd-card-512mb","title":"Siemens 6SL3054-4AG00-2AA0 SINAMICS SD Card 512 MB Empty VFD Memory Card","description":"\u003cp\u003eThe Siemens 6SL3054-4AG00-2AA0 is a 512 MB empty SD card for the SINAMICS drive family. It provides onboard non-volatile storage for drive parameter sets, firmware, and application data, enabling fast commissioning and parameter transfer across multiple drive units without a PC connection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3054-4AG00-2AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4042948664049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSD Card 512 MB, empty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85235110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6SL3054-4AG00-2AA0 ships blank, making it the correct choice when you need to load a custom or site-specific parameter set rather than a pre-cloned drive image. Insert it into a compatible SINAMICS drive (such as the V20 or G120 series), then use the drive's upload function or STARTER\/Startdrive to write parameters directly to the card. At 512 MB, the card accommodates firmware files and multiple parameter backups simultaneously — useful on multi-drive installations where a single card is rotated through units during commissioning.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959402422555,"sku":"6SL3054-4AG00-2AA0","price":43.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3054-4ag00-2aa0-sinamics-sd-card-512mb.png?v=1789641264"},{"product_id":"siemens-6sl3201-2ad20-8va0-sinamics-v20-braking-module","title":"Siemens 6SL3201-2AD20-8VA0 SINAMICS V20 Braking Module 400V\/230V VFD Braking Module","description":"\u003cp\u003eThe Siemens 6SL3201-2AD20-8VA0 is a SINAMICS V20 braking module rated 380-480 V 3AC input \/ 200-240 V output, housed in a compact 90 x 150 x 88 mm (W x H x D) enclosure weighing 0.7 kg. It supports a duty cycle from 5% to 100%, allowing continuous energy dissipation in SINAMICS V20 applications with frequent braking cycles.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3201-2AD20-8VA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e6940408102842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS V20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V 3AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e5% ... 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e90 x 150 x 88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 5-100% duty cycle rating means this module can handle continuous braking duty, not just occasional stops - relevant for hoists, centrifuges, or unwind\/rewind axes on a SINAMICS V20 drive where the motor regenerates energy frequently. Match the 380-480 V 3AC input rating to the drive's line voltage class before ordering; a 200 V class V20 drive requires the corresponding lower-voltage braking module variant.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePairs with SINAMICS V20 drives on 380-480 V 3AC supplies to dissipate regenerative energy from decelerating loads such as hoists, winders, and centrifuges.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959404388635,"sku":"6SL3201-2AD20-8VA0","price":122.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3201-2ad20-8va0-braking-module-vfd-braking-module.png?v=1789681331"},{"product_id":"siemens-6sl3210-1pb13-0ul0-sinamics-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PB13-0UL0 SINAMICS PM240-2 IP20 FSA 230V 0.55kW VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB13-0UL0 is a SINAMICS G120 PM240-2 Power Module, unfiltered with an integrated braking chopper, rated for 200–240 V 1\/3 AC input and 0.55 kW (Low Overload) \/ 0.37 kW (High Overload) output at 230 V IEC. Frame size FSA, degree of protection IP20, the module measures 196 × 73 × 165 mm (H×W×D) and weighs 1.4 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB13-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4042948666210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2 IP20-FSA-U-230V-0.55KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 … 240 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 … 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V IEC \/ 240 V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power — Low Overload (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kW (0.75 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power — High Overload (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kW (0.50 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (LO) — 1-phase \/ 3-phase input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.50 A \/ 4.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (HO) — 1-phase \/ 3-phase input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.60 A \/ 3.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (LO) — Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (HO) — Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency — Vector Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 … 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency — V\/f Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 … 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLO Overload Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 % for 3 s, 110 % for 57 s, 100 % for 240 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHO Overload Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 % for 3 s, 150 % for 57 s, 100 % for 240 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Air Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 m³\/s (0.177 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude (without derating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1,000 m (3,280 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature — LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 … +40 °C (14 … 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature — HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 … +50 °C (14 … 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 … +55 °C (-13 … +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e196 × 73 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Braking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnfiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum CU Firmware Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV4.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6SL3210-1PB13-0UL0 accepts both single-phase and three-phase 200–240 V supply, making it deployable in 230 V single-phase infrastructure without a separate line reactor — useful in retrofit situations where a three-phase feed is unavailable. At the LO rating of 0.55 kW, the maximum ambient is 40 °C; switching to the HO profile (0.37 kW, 200 % overload for 3 s) raises the ceiling to 50 °C, which matters in warm control-cabinet environments. The integrated braking chopper eliminates the need for an external braking module at this power level, keeping FSA footprint at 73 mm wide. For applications needing 0.75 kW LO or a filtered variant, step up to the next frame or the PM240-2 F (filtered) equivalent; for sub-0.37 kW loads, a smaller frame reduces panel space further. This module ships without a Control Unit — pair it with a CU240B-2, CU240E-2, or CU250S-2 running firmware ≥ V4.6.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959404781851,"sku":"6SL3210-1PB13-0UL0","price":245.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb13-0ul0-pm240-2-vfd-power-module.png?v=1789641270"},{"product_id":"siemens-6sl3210-1pb13-8ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PB13-8UL0 SINAMICS G120 PM240-2 FSA 0.75kW 230V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB13-8UL0 is a SINAMICS G120 Power Module PM240-2 in FSA frame, rated 0.75kW low overload \/ 0.55kW high overload at 200-240V 1\/3AC input, with an integrated braking chopper. Output current reaches 6.40A max at a 4kHz pulse frequency, unfiltered and rated IP20 without Control Unit or operating unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB13-8UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e9.60 A \/ 5.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e8.40 A \/ 4.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage (3AC output)\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e0.75 kW \/ 1.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e0.55 kW \/ 0.75 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e4.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e3.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e6.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.005 m3\/s (0.177 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis FSA-frame PM240-2 covers the 0.75kW (LO) \/ 0.55kW (HO) power point, the smallest rating in the PM240-2 range at 200-240V single\/three-phase input, with a 4.20A rated LO current and a 6.40A maximum output current for loads with occasional 150% or 200% overload peaks. The built-in braking chopper lets a braking resistor connect directly without a separate module, and because the module is unfiltered, an external EMC filter is needed where conducted-emission limits apply. Higher power points in the same PM240-2 family step up from FSA to FSB and FSC frames.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 modular drive together with a matching Control Unit for small pumps, fans, and conveyor motors on a 200-240V supply. Requires Control Unit firmware V4.6 or later; rated for -10 to 40C at low overload and -10 to 50C at high overload.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959405175067,"sku":"6SL3210-1PB13-8UL0","price":265.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb13-8ul0-pm240-2-vfd-power-module.png?v=1789714238"},{"product_id":"siemens-6sl3210-1pb15-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PB15-5UL0 SINAMICS G120 PM240-2 FSB 1.1kW 230V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB15-5UL0 is a SINAMICS G120 Power Module PM240-2 in FSB frame, rated 1.1kW low overload \/ 0.75kW high overload at 200-240V 1\/3AC input, with an integrated braking chopper. Output current reaches 9.00A max at a 4kHz pulse frequency, unfiltered and rated IP20 without Control Unit or operating unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB15-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e13.50 A \/ 7.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e11.80 A \/ 6.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage (3AC output)\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e1.10 kW \/ 1.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e0.75 kW \/ 1.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e6.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e4.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e9.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.05 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.009 m3\/s (0.325 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis FSB-frame PM240-2 covers the 1.1kW (LO) \/ 0.75kW (HO) power point, one step up from the FSA frame's 0.75kW \/ 0.55kW rating, with a 6.00A rated LO current and a 9.00A maximum output current for loads with occasional overload peaks. The built-in braking chopper lets a braking resistor connect directly without a separate module, and because the module is unfiltered, an external EMC filter is needed where conducted-emission limits apply. Larger power points in the same PM240-2 family continue into the FSC frame and beyond.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 modular drive together with a matching Control Unit for pumps, fans, and conveyor motors on a 200-240V supply. Requires Control Unit firmware V4.6 or later; rated for -10 to 40C at low overload and -10 to 50C at high overload.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959406387483,"sku":"6SL3210-1PB15-5UL0","price":284.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb15-5ul0-pm240-2-vfd-power-module.png?v=1789714245"},{"product_id":"siemens-6sl3210-1pb17-4ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PB17-4UL0 SINAMICS G120 PM240-2 IP20 FSB 230V 1.5kW VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB17-4UL0 is a SINAMICS G120 PM240-2 power module in IP20 FSB frame, rated 1.5 kW low-overload (1.1 kW high-overload) from a 200-240 V single\/three-phase supply, delivering up to 12 A output current. Built-in braking chopper and internal air cooling let it drive loads to 7.40 A continuous without an external filter.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB17-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948666241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO), 1AC \/ 3AC\u003c\/td\u003e\n\u003ctd\u003e18.10 A \/ 10.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO), 1AC \/ 3AC\u003c\/td\u003e\n\u003ctd\u003e15.80 A \/ 9.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e1.50 kW (2.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e1.10 kW (1.50 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e7.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e6.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e12.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.07 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.009 m3\/s (0.325 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated for both LO (light overload, 150% for 60s) and HO (heavy overload, 200% for 3s) duty per its 1.50 kW \/ 1.10 kW split rating - choose the HO rating for high-inertia loads needing frequent overload headroom, and the LO rating where overload events are rare. The single\/three-phase 200-240 V input (18.10 A single-phase vs 10.50 A three-phase LO current) lets it run from either a single-phase or three-phase 230 V supply - check the higher single-phase input current against the branch circuit before wiring 1-phase. Because filtering is not built in, add an external EMC filter where conducted emissions limits apply; the built-in braking chopper avoids a separate braking module for moderate braking duty.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits SINAMICS G120 systems on machines needing a 230 V class drive up to 1.5 kW - conveyors, pumps, and fans supplied from either single-phase or three-phase 200-240 V mains.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959406780699,"sku":"6SL3210-1PB17-4UL0","price":324.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb17-4ul0-pm240-2-power-module.png?v=1789681337"},{"product_id":"siemens-6sl3210-1pb21-0ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PB21-0UL0 SINAMICS G120 PM240-2 1.5kW\/2.2kW 200-240V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB21-0UL0 is a SINAMICS G120 PM240-2 power module for 1\/3AC 200-240V supply, rated 1.50 kW at high overload and 2.20 kW at low overload in the compact FSB frame. It has a built-in braking chopper, ships without an input filter, control unit, or operator panel, and is approved from CU firmware version V4.6 onward. IP20 protection and a 3.0 kg weight suit direct panel mounting in a 291 x 100 x 165 mm footprint.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB21-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948666258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e291 x 100 x 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e24.00 A \/ 13.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e20.90 A \/ 12.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e2.20 kW \/ 3.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e1.50 kW \/ 2.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e10.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e7.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e15.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.009 m³\/s (0.325 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 °C (14 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 °C (14 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe dual rating - 1.50 kW at high overload, 2.20 kW at low overload - lets the same FSB module cover a constant-torque load such as a conveyor at the high-overload figure, or a quadratic-torque load such as a fan or pump at the higher low-overload figure; size by the duty class the machine actually needs, not the nameplate maximum. Because the module ships without a filter, add an external EMC filter where the installation must meet conducted-emission limits beyond the unfiltered baseline. The integrated braking chopper covers occasional regeneration, such as a load lowering under gravity, without a separate braking module; a sustained regenerative duty cycle still needs an external braking resistor.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959408058651,"sku":"6SL3210-1PB21-0UL0","price":382.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb21-0ul0-pm240-2-vfd-power-module.png?v=1790181456"},{"product_id":"siemens-6sl3210-1pb21-4ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PB21-4UL0 SINAMICS G120 PM240-2 FSC 3kW 230V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB21-4UL0 is a SINAMICS G120 Power Module PM240-2 in FSC frame, rated 3.00kW low overload \/ 2.20kW high overload at 200-240V 1\/3AC input, with an integrated braking chopper. Output current reaches 20.80A max at a 4kHz pulse frequency, unfiltered and rated IP20 without Control Unit or operating unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB21-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e35.90 A \/ 20.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e31.30 A \/ 18.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage (3AC output)\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e3.00 kW \/ 4.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e2.20 kW \/ 3.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e13.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e10.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e20.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.14 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.018 m3\/s (0.653 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis FSC-frame PM240-2 covers the 3.00kW (LO) \/ 2.20kW (HO) power point, larger than the FSB frame's 1.1kW \/ 0.75kW rating, with a 13.60A rated LO current and a 20.80A maximum output current for loads with occasional overload peaks. The built-in braking chopper lets a braking resistor connect directly without a separate module, and because the module is unfiltered, an external EMC filter is needed where conducted-emission limits apply. The same FSC frame also houses a 4kW PM240-2 variant one step further up the power range.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 modular drive together with a matching Control Unit for pumps, fans, and conveyor motors on a 200-240V supply. Requires Control Unit firmware V4.6 or later; rated for -10 to 40C at low overload and -10 to 50C at high overload.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959409238299,"sku":"6SL3210-1PB21-4UL0","price":480.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb21-4ul0-pm240-2-vfd-power-module.png?v=1789714251"},{"product_id":"siemens-6sl3210-1pb21-8ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PB21-8UL0 SINAMICS G120 PM240-2 FSC 4kW 230V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PB21-8UL0 is a SINAMICS G120 Power Module PM240-2 in FSC frame, rated 4.00kW low overload \/ 3.00kW high overload at 200-240V 1\/3AC input, with an integrated braking chopper. Output current reaches 27.20A max at a 4kHz pulse frequency, unfiltered and rated IP20 without Control Unit or operating unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PB21-8UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e1 \/ 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e200 ... 240 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e43.00 A \/ 24.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 1AC\/3AC input\u003c\/td\u003e\n\u003ctd\u003e37.50 A \/ 21.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage (3AC output)\u003c\/td\u003e\n\u003ctd\u003e230V IEC \/ 240V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e4.00 kW \/ 5.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e3.00 kW \/ 4.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO), 3AC\u003c\/td\u003e\n\u003ctd\u003e17.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO), 3AC\u003c\/td\u003e\n\u003ctd\u003e13.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e27.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.018 m3\/s (0.653 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis FSC-frame PM240-2 covers the 4.00kW (LO) \/ 3.00kW (HO) power point, the top rating in the FSC frame, with a 17.50A rated LO current and a 27.20A maximum output current for loads with occasional overload peaks. The built-in braking chopper lets a braking resistor connect directly without a separate module, and because the module is unfiltered, an external EMC filter is needed where conducted-emission limits apply. Choose this variant over a lower 3kW\/2.2kW FSC unit when the driven motor's continuous current exceeds roughly 13.6A LO or 10.4A HO.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 modular drive together with a matching Control Unit for pumps, fans, and conveyor motors on a 200-240V supply. Requires Control Unit firmware V4.6 or later; rated for -10 to 40C at low overload and -10 to 50C at high overload.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959410745627,"sku":"6SL3210-1PB21-8UL0","price":579.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pb21-8ul0-pm240-2-vfd-power-module.png?v=1789714258"},{"product_id":"siemens-6sl3210-1pe11-8ul1-pm240-2-0-55kw-power-module","title":"Siemens 6SL3210-1PE11-8UL1 SINAMICS PM240-2 0.55kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE11-8UL1 is a SINAMICS PM240-2 power module rated 0.55 kW in Low Overload mode and 0.37 kW in High Overload mode, for 380-480 V 3 AC input, frame size FSA, IP20 without Control Unit. It has an integrated braking chopper, is unfiltered for EMC, and is released from CU firmware version V4.6 for use with a compatible SINAMICS Control Unit to form a modular G120 drive.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE11-8UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2, unfiltered, integrated braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (without Control Unit and operator panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 - 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 - 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kW \/ 0.75 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kW \/ 0.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V IEC \/ 480 V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (Vector Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (V\/f Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.005 m3\/s air requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m (3280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport \/ Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eLow Overload (LO) mode gives the higher continuous rating, 0.55 kW at 150% overload for 57 s, and suits variable-torque loads such as pumps and fans; High Overload (HO) mode drops continuous power to 0.37 kW but allows 200% for 3 s, which fits constant-torque loads with load spikes such as conveyors. Choose the next higher power rating in frame size FSA when the application's continuous current exceeds this module's 1.70 A \/ 1.30 A output rating, and choose the filtered variant instead of this unfiltered one where EN 61800-3 conducted-emission limits must be met at the drive terminals.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSpeed control of small three-phase asynchronous or synchronous-reluctance motors in modular SINAMICS G120 drives, paired with a matching SINAMICS Control Unit, for pumps, fans, and light conveyors on a 380-480 V 3 AC supply.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959412089115,"sku":"6SL3210-1PE11-8UL1","price":272.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe11-8ul1-pm240-2-0-55kw-vfd-power-module.png?v=1789663686"},{"product_id":"siemens-6sl3210-1pe12-3ul1-pm240-2-power-module","title":"Siemens 6SL3210-1PE12-3UL1 SINAMICS PM240-2 0.75kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE12-3UL1 is a SINAMICS PM240-2 power module rated 0.75 kW (low overload) \/ 0.55 kW (high overload) at 400 V, built for 380-480 V 3AC ±10% supply at 47-63 Hz. Frame size FSA carries an integrated braking chopper and IP20 protection without the Control Unit, and it needs CU firmware V4.6 or later to operate.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE12-3UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 \/ PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 V ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current (LO \/ HO)\u003c\/td\u003e\n\u003ctd\u003e2.90 A \/ 2.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V IEC \/ 480 V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (LO \/ HO)\u003c\/td\u003e\n\u003ctd\u003e0.75 kW \/ 0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current (LO \/ HO)\u003c\/td\u003e\n\u003ctd\u003e2.20 A \/ 1.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e3.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Vector Control)\u003c\/td\u003e\n\u003ctd\u003e0 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (V\/f Control)\u003c\/td\u003e\n\u003ctd\u003e0 to 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-10 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 0.75 kW low-overload \/ 0.55 kW high-overload FSA frame variant — pick the low-overload rating for pumps and fans with light, continuous loads, and treat the high-overload figure as the ceiling for applications with overload spikes such as conveyors or mixers. The unfiltered designation means an external EMC filter is needed if the installation requires Class A or B conducted-emission compliance; the integrated braking chopper lets a braking resistor be added directly at this power module without a separate chopper module. IP20 protection applies only without the Control Unit and operator panel fitted, so mount it inside an enclosed cabinet.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSingle-axis pump, fan, and conveyor drives on the SINAMICS G120 modular platform where a separate Control Unit provides PROFINET\/PROFIBUS control of the power stage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959413170459,"sku":"6SL3210-1PE12-3UL1","price":294.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe12-3ul1-pm240-2-power-module.png?v=1789663692"},{"product_id":"siemens-6sl3210-1pe13-2ul1-sinamics-pm240-2-power-module","title":"Siemens 6SL3210-1PE13-2UL1 SINAMICS PM240-2 FSA 1.1kW 380-480V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE13-2UL1 is a SINAMICS PM240-2 power module, frame size FSA, unfiltered, with an integrated braking chopper for 380-480 V 3 AC supply. It delivers 1.10 kW at low overload, 150% for 57 s, or 0.75 kW at high overload, 200% for 3 s, with a maximum output current of 4.70 A. IP20 protection, without Control Unit or operator panel.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE13-2UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 V, +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, low overload\u003c\/td\u003e\n\u003ctd\u003e4.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, high overload\u003c\/td\u003e\n\u003ctd\u003e3.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400 V IEC, 480 V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power, low overload\u003c\/td\u003e\n\u003ctd\u003e1.10 kW, 1.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power, high overload\u003c\/td\u003e\n\u003ctd\u003e0.75 kW, 1.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, low overload (2)\u003c\/td\u003e\n\u003ctd\u003e3.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, high overload (2)\u003c\/td\u003e\n\u003ctd\u003e2.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e4.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 to 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.04 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.005 m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation, low overload\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation, high overload\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis PM240-2 module is rated 1.10 kW at low overload, 150% for 57 s, 100% continuous up to 40 degrees C, or 0.75 kW at high overload, 200% for 3 s, 100% continuous up to 50 degrees C. Pick the low-overload rating for centrifugal loads like pumps and fans with steady torque, and the high-overload rating for applications needing short-duration torque spikes, such as extruders or positioning axes, at the cost of a lower continuous ambient rating. It is unfiltered, so an external EMC filter is required where conducted-emission limits apply, and the integrated braking chopper handles regenerative energy from decelerating loads without a separate braking module. Frame size FSA fits motors around this power range; move to a larger frame size for higher power.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to small pump, fan, and conveyor drives on a SINAMICS G120 system built from a separate Power Module and Control Unit, where the braking chopper handles occasional deceleration energy without an external braking module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959414251803,"sku":"6SL3210-1PE13-2UL1","price":316.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe13-2ul1-sinamics-pm240-2-power-module.png?v=1789663277"},{"product_id":"siemens-6sl3210-1pe14-3ul1-pm240-2-1-5kw-vfd-power-module","title":"Siemens 6SL3210-1PE14-3UL1 SINAMICS PM240-2 1.5kW\/1.1kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE14-3UL1 is a SINAMICS PM240-2 power module in frame size FSA, unfiltered with an integrated braking chopper, rated for 380-480 V 3 AC input. It delivers 1.5 kW at low overload (150% for 57 s) or 1.1 kW at high overload (200% for 3 s), requiring a separate Control Unit to operate.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE14-3UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 \/ PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2, Frame Size FSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V 3 AC, ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50 kW (2.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.10 kW (1.50 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Capability (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150% for 57 s, 100% for 240 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Capability (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200% for 3 s, 150% for 57 s, 100% for 240 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (Vector Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (V\/f Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnfiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Low Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 ... +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (High Overload)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 ... +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (without Control Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1.5 kW low-overload rating suits pumps and fans with light, continuous torque demand, while the 1.1 kW high-overload rating covers applications needing a 200% current spike for 3 s, such as a conveyor start against a loaded belt. Because this is an unfiltered PM240-2, an external EMC filter is required where conducted emissions limits apply; the filtered PM240-2 variant in the same frame size skips that added component. The integrated braking chopper dissipates regenerative energy from decelerating loads directly through a braking resistor without an external braking unit, and the module needs a compatible SINAMICS Control Unit (CU firmware V4.6 or later) to run — it is not a standalone drive.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eVariable speed control of pumps, fans, and conveyors in the 1.1-1.5 kW range on a 380-480 V 3 AC supply, where cabinet space favors the modular PM240-2\/Control Unit architecture over a compact all-in-one drive.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959415333147,"sku":"6SL3210-1PE14-3UL1","price":360.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe14-3ul1-pm240-2-power-module.png?v=1789663517"},{"product_id":"siemens-6sl3210-1pe16-1ul1-sinamics-pm240-2-power-module","title":"Siemens 6SL3210-1PE16-1UL1 SINAMICS PM240-2 2.2kW 400V IP20 Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE16-1UL1 is a SINAMICS PM240-2 power module (Frame Size A, unfiltered) with an integrated braking chopper, rated 2.2 kW low-overload \/ 1.5 kW high-overload from a 380-480 V 3 AC supply. Max output current is 8.9 A at up to 4 kHz pulse frequency. It weighs 1.38 kg and requires a Control Unit running firmware V4.6 or later.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE16-1UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 (PM240-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e3 AC, 380-480 V ±10%, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (Low Overload)\u003c\/td\u003e\n\u003ctd\u003e2.2 kW (3.0 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (High Overload)\u003c\/td\u003e\n\u003ctd\u003e1.5 kW (2.0 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rated Current (LO \/ HO)\u003c\/td\u003e\n\u003ctd\u003e7.70 A \/ 6.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rated Current (LO \/ HO)\u003c\/td\u003e\n\u003ctd\u003e5.90 A \/ 4.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e8.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, Vector Control\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, V\/f Control\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.005 m³\/s airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003eup to 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-10 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e196 x 73 x 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Firmware\u003c\/td\u003e\n\u003ctd\u003eCU firmware V4.6 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRating depends on overload class: at low overload (LO, light\/variable-torque loads like pumps and fans) this module delivers 2.2 kW continuous with 150% for 57 s; at high overload (HO, constant-torque loads) it drops to 1.5 kW with 200% for 3 s — size it against the load's actual overload profile, not just the continuous kW figure. The integrated braking chopper handles dynamic braking energy without an external braking module, useful for applications with frequent deceleration such as hoists or centrifuges, as long as a braking resistor is fitted. It requires a CU240 Control Unit running firmware V4.6 or later — check the paired control unit's firmware before combining with an existing G120 build.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage in modular SINAMICS G120 drives for pumps, fans, conveyors and mixers in the 1.5-2.2 kW range, paired separately with a CU240 control unit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462125851,"sku":"6SL3210-1PE16-1UL1","price":425.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe16-1ul1-sinamics-pm240-2-power-module.png?v=1789663699"},{"product_id":"siemens-6sl3210-1pe18-0ul1-pm240-2-380-480v-3kw-power-module","title":"Siemens 6SL3210-1PE18-0UL1 SINAMICS PM240-2 380-480V 3kW FSA IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE18-0UL1 is a SINAMICS PM240-2 power module in frame size FSA with an integrated braking chopper, rated 380-480 V 3 AC, 47-63 Hz. Low-overload power is 3.00 kW and high-overload power is 2.20 kW, with a maximum output current of 11.80 A and IP20 protection without control unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE18-0UL1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e380-480 V 3 AC +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power, Low Overload (LO)\u003c\/td\u003e\n\u003ctd\u003e3.00 kW \/ 4.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power, High Overload (HO)\u003c\/td\u003e\n\u003ctd\u003e2.20 kW \/ 3.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current, Low Overload\u003c\/td\u003e\n\u003ctd\u003e7.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current, High Overload\u003c\/td\u003e\n\u003ctd\u003e5.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e11.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, Vector Control\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, V\/f Control\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Low Overload\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, High Overload\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe high-overload (HO) rating of 2.20 kW at up to 200% for 3 s covers punch, cutting, or press-type loads with brief torque spikes, while the low-overload (LO) 3.00 kW rating with only 150% for 3 s fits centrifugal pumps and fans with steady loading - pick the duty class that matches the load profile rather than the higher kW number by default. The integrated braking chopper drives an external braking resistor directly for fast-decelerating loads without an add-on braking module. As a Power Module rather than a Control Unit, it requires a matching CU (e.g. CU230P-2 or CU240E-2) to form a complete SINAMICS G120 drive.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eVariable-speed control of 3-phase induction motors up to 3 kW (LO) or 2.2 kW (HO) on 380-480 V supplies, in modular SINAMICS G120 drive assemblies for pumps, fans, and general machine axes.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462289691,"sku":"6SL3210-1PE18-0UL1","price":534.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe18-0ul1-pm240-2-power-module.png?v=1789664136"},{"product_id":"siemens-6sl3210-1pe21-1ul0-sinamics-pm240-2-4kw-power-module","title":"Siemens 6SL3210-1PE21-1UL0 SINAMICS PM240-2 3AC 400V 4kW IP20 Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE21-1UL0 is a SINAMICS PM240-2 power module rated 4 kW low-overload \/ 3 kW high-overload at 3 AC 380-480 V input, with a built-in braking chopper and IP20 protection in frame size FSB. It supplies output current up to 15.4 A and is ordered without a control unit or operator panel.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE21-1UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120 PM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V +\/-10%, 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.00 kW (5.00 hp) \/ 3.00 kW (4.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current @400V, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.30 A \/ 11.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current @480V, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.20 A \/ 7.70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency, Vector \/ V-f\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz \/ 0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 C \/ -10 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size \/ IP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSB \/ IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe 4 kW\/3 kW LO\/HO split follows Siemens' dual-rating convention: use the 4 kW low-overload figure for continuous, steady loads such as pumps and fans, and the 3 kW high-overload figure when the application needs 200% torque for 3 s starting transients such as conveyors or positioning axes. The built-in braking chopper removes the need for a separate braking module wherever the drive needs dynamic braking, such as vertical axes or fast decelerations. Frame size FSB and IP20 protection mean it is a power stage for cabinet mounting only - a G120 control unit is still required to run it.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eUsed in modular SINAMICS G120 drive assemblies for pumps, fans, conveyors, and mixers in the 3-5 kW range where the built-in braking chopper handles occasional dynamic braking.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462420763,"sku":"6SL3210-1PE21-1UL0","price":643.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe21-1ul0-sinamics-pm240-2-4kw-power-module.png?v=1789664754"},{"product_id":"siemens-6sl3210-1pe21-4ul0-pm240-2-5-5kw-400v","title":"Siemens 6SL3210-1PE21-4UL0 SINAMICS G120 PM240-2 5.5kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE21-4UL0 is a SINAMICS G120 PM240-2 power module rated 5.5kW low overload (LO) \/ 4.0kW high overload (HO) at 380-480V 3AC, IP20, with a built-in braking chopper and no line filter fitted. It requires a separate SINAMICS control unit to run, ships without a control unit or operator panel, and supports control unit firmware version V4.6.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE21-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.50 kW \/ 7.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.00 kW \/ 5.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated output current, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated output current, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200% 3s, 150% 57s, 100% 240s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150% 3s, 110% 57s, 100% 240s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput frequency, vector control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput frequency, V\/f control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.009 m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e291 x 100 x 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\/storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe built-in braking chopper means no separate braking module is needed for dynamic braking within its capacity, which matters for overhauling loads or fast decel cycles. The HO rating (4.0kW, 200% overload for 3s) suits constant-torque loads such as conveyors that need high starting torque, while the LO rating (5.5kW, 150% overload for 3s) suits variable-torque loads like pumps and fans that run mostly at steady speed. This module ships without a line filter, so an external EMC filter is required where conducted-emission limits apply, and it needs a separate SINAMICS control unit since the power module itself has no onboard control electronics or operator interface.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eMotor control for pumps, fans and conveyors in the 4-5.5kW range on modular SINAMICS G120 drive systems where a built-in braking chopper is needed without an EMC filter fitted at the power module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462650139,"sku":"6SL3210-1PE21-4UL0","price":752.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe21-4ul0-pm240-2-vfd-power-module.png?v=1789664378"},{"product_id":"siemens-6sl3210-1pe22-7ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE22-7UL0 SINAMICS G120 PM240-2 11kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE22-7UL0 is a SINAMICS PM240-2 power module rated 11 kW low-overload \/ 7.5 kW high-overload at 3AC 380-480V, with an integrated braking chopper and an IP20 FSC-frame enclosure. It pairs with a separate SINAMICS G120 control unit, runs on a 47-63 Hz line, and delivers up to 39 A maximum output current for V\/f- or vector-controlled loads.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE22-7UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948666104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2, without filter, built-in braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO)\u003c\/td\u003e\n\u003ctd\u003e32.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO)\u003c\/td\u003e\n\u003ctd\u003e27.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (LO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (HO)\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO) (2)\u003c\/td\u003e\n\u003ctd\u003e26.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO) (2)\u003c\/td\u003e\n\u003ctd\u003e18.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e39.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Vector Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (V\/f Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Air Requirement\u003c\/td\u003e\n\u003ctd\u003e0.018 m3\/s (0.653 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (LO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (HO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temp\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick this module by load type: 11 kW low-overload (LO) suits variable-torque duty such as pumps and fans, while 7.5 kW high-overload (HO) suits constant-torque loads needing 150% for 57 s of a cycle. It ships without an EMC filter, so a filter has to be added externally if the installation needs a defined emissions class - the with-filter version of the same PM240-2 frame removes that extra step. The built-in braking chopper accepts a resistor directly, without a separate chopper module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits SINAMICS G120 assemblies running variable-torque pump and fan loads at 11 kW, or constant-torque conveyor and agitator loads at 7.5 kW, in cabinets that already handle EMC filtering and use a SINAMICS G120 control unit for the fieldbus connection.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462781211,"sku":"6SL3210-1PE22-7UL0","price":1308.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe22-7ul0-pm240-2-vfd-power-module.png?v=1789664761"},{"product_id":"siemens-6sl3210-1pe23-3ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE23-3UL0 SINAMICS G120 PM240-2 15kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE23-3UL0 is a SINAMICS PM240-2 power module rated 15 kW low-overload \/ 11 kW high-overload at 3AC 380-480V, with an integrated braking chopper and an IP20 FSC-frame enclosure. It pairs with a separate SINAMICS G120 control unit, accepts a 47-63 Hz line frequency, and delivers up to 52 A maximum output current for V\/f- or vector-controlled motor loads.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE23-3UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948666128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2, without filter, built-in braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO)\u003c\/td\u003e\n\u003ctd\u003e39.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO)\u003c\/td\u003e\n\u003ctd\u003e36.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (LO)\u003c\/td\u003e\n\u003ctd\u003e15.00 kW \/ 20.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (HO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO) (2)\u003c\/td\u003e\n\u003ctd\u003e32.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO) (2)\u003c\/td\u003e\n\u003ctd\u003e26.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e52.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Vector Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (V\/f Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Air Requirement\u003c\/td\u003e\n\u003ctd\u003e0.018 m3\/s (0.653 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (LO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 40 C (14 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (HO)\u003c\/td\u003e\n\u003ctd\u003e-10 ... 50 C (14 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temp\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe two overload ratings on this module define which load type it fits: the 15 kW low-overload (LO) rating covers variable-torque loads such as pumps and fans, while the 11 kW high-overload (HO) rating covers constant-torque loads that need 150% for 57 s. Because this is the without-filter variant, add an external EMC filter if the installation needs a defined conducted-emissions class; a with-filter power module in the same PM240-2 frame skips that step. The built-in braking chopper lets a braking resistor be wired directly without a separate chopper module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits SINAMICS G120 drive assemblies for variable-torque pump and fan duty at 15 kW, or constant-torque conveyor and mixer duty at 11 kW, wherever a control cabinet already handles EMC filtering and a SINAMICS G120 control unit provides the fieldbus interface.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959462879515,"sku":"6SL3210-1PE23-3UL0","price":1744.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe23-3ul0-pm240-2-vfd-power-module.png?v=1789664767"},{"product_id":"siemens-6sl3210-1pe23-8ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PE23-8UL0 SINAMICS G120 PM240-2 400V 18.5kW FSD VFD Power Module","description":"\u003cp\u003eThe Siemens SINAMICS G120 PM240-2 (6SL3210-1PE23-8UL0) is a frame size FSD power module for 3 AC 380-480 V supply, rated 18.5 kW \/ 38 A output at low overload and 15 kW \/ 32 A at high overload, with a built-in braking chopper. It runs without a filter, covers 0-550 Hz in V\/f control, and carries IP20 protection for panel mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE23-8UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V AC +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (IEC) \/ 480 V (NEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.00 A \/ 33.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current, LO \/ HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.00 A \/ 32.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.50 kW (25 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.00 kW (20 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency, Vector Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency, V\/f Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temp., Operation LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temp., Operation HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe FSD frame's 18.5 kW low-overload \/ 15 kW high-overload split lets the same power module cover pump- or fan-type loads at the higher 18.5 kW rating, or true constant-torque loads at 15 kW - size it against the actual overload duty cycle, not just peak motor power. The built-in braking chopper handles regenerative energy from decelerating loads without an external braking module, though a braking resistor is still needed to dissipate that energy. Ordering without a filter means a separate EMC or output filter must be added where the installation requires one.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eVariable-speed control of 3-phase induction motors on pumps, fans, conveyors, and mixers in the 15-18.5 kW class, where this modular power module plus a matching control unit forms the complete drive. IP20 protection suits enclosed control-panel installation rather than direct field mounting.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959463010587,"sku":"6SL3210-1PE23-8UL0","price":2159.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe23-8ul0-pm240-2-vfd-power-module.png?v=1789664773"},{"product_id":"siemens-6sl3210-1pe24-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE24-5UL0 SINAMICS G120 PM240-2 400V 22kW IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens SINAMICS G120 PM240-2 power module 6SL3210-1PE24-5UL0 delivers 22 kW low-overload and 18.5 kW high-overload output at 400 V 3AC, with a built-in braking chopper and an IP20 frame size FSD enclosure. It pairs with a separate control unit to form a modular G120 drive, rated for a 380-480 V line supply at 47-63 Hz.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE24-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e42.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e38.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e22.00 kW \/ 30.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e18.50 kW \/ 25.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e45.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e76.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.68 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m3\/s (1.942 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating humidity\u003c\/td\u003e\n\u003ctd\u003e95 %, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e16.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 22 kW LO \/ 18.5 kW HO this is a lighter frame FSD variant than the higher-current PM240-2 modules in the same series, at 16.6 kg against 18.3 kg for the next size up, which matters when the drive cabinet's mounting plate or lifting limit is a constraint. The 45 A output current headroom over the 42 A line-side LO rating gives margin for a motor running close to its nameplate current without tripping on the HO duty cycle (150% for 3 s, 110% for 57 s). As with the rest of the modular G120 line, this power module ships without a control unit, so a CU240 or CU250S-2 plus operator panel is needed to complete the drive.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSized for 18.5-22 kW induction motors in modular G120 drive cabinets: pumps, fans, and conveyors in the mid-power range where the plant standardizes on separate power module and control unit hardware.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959463141659,"sku":"6SL3210-1PE24-5UL0","price":2483.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe24-5ul0-pm240-2-power-module.png?v=1789679102"},{"product_id":"siemens-6sl3210-1pe26-0ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE26-0UL0 SINAMICS G120 PM240-2 30kW 400V IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE26-0UL0 is a SINAMICS G120 PM240-2 power module rated 30 kW low overload \/ 22 kW high overload from a 380-480 V three-phase supply. It includes a built-in braking chopper but no line filter, mounts in IP20 frame size D, and pairs with a CU240 control unit to form a complete G120 drive.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE26-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePM240-2 Power Module, without filter, built-in braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e380 V to 480 V +10% \/ -20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 Hz to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V (IEC) \/ 480 V (NEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (LO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (HO)\u003c\/td\u003e\n\u003ctd\u003e22.00 kW \/ 30.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO)\u003c\/td\u003e\n\u003ctd\u003e57.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO)\u003c\/td\u003e\n\u003ctd\u003e47.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO), 2nd rating\u003c\/td\u003e\n\u003ctd\u003e60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO), 2nd rating\u003c\/td\u003e\n\u003ctd\u003e45.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e90.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 to 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.77 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling; 0.055 m3\/s air requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude, max.\u003c\/td\u003e\n\u003ctd\u003e1,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-20C to 40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-20C to 50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\/Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25C to 55C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e18.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis PE26 variant omits the integrated line filter, so an external EMC filter is needed if the installation requires Category C2\/C3 conformance - choose the filtered PM240-2 variant instead when there is no panel space for a separate filter. The built-in braking chopper dissipates regenerative energy from decelerating loads without an external braking module, up to the chopper's rated duty. Rated 30 kW at low overload (150% for 3 s) versus 22 kW at high overload (200% for 3 s), it suits centrifugal-load applications like pumps and fans better than high-inertia loads that need the HO rating's higher instantaneous overload margin.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMotor speed control for pumps, fans, and conveyors on 380-480 V three-phase supplies, paired with a CU240 control unit and, where required, an external EMC filter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959463862555,"sku":"6SL3210-1PE26-0UL0","price":3131.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe26-0ul0-pm240-2-power-module.png?v=1789679108"},{"product_id":"siemens-6sl3210-1pe27-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE27-5UL0 SINAMICS G120 PM240-2 400V 37kW IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens SINAMICS G120 PM240-2 power module 6SL3210-1PE27-5UL0 delivers 37 kW low-overload and 30 kW high-overload output at 400 V 3AC, with a built-in braking chopper and an IP20 frame size FSD enclosure. It pairs with a separate control unit to form a modular G120 drive, rated for a 380-480 V line supply at 47-63 Hz.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE27-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e70.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e62.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e75.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e120.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.01 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m3\/s (1.942 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LO (low overload) rating of 37 kW covers pump and fan loads that only need 110% overload for 57 s, while the HO (high overload) rating of 30 kW is the figure to size against for conveyor or extrusion loads that need 150% for 3 s. Choose this frame over the lower-current PM240-2 variants in the same series when the driven motor's full-load current exceeds roughly 62 A; the built-in braking chopper removes the need for an external chopper module when a braking resistor is added for fast-stop or overhauling-load applications. The module ships without a control unit, so a CU240 or CU250S-2 control unit and an operator panel must be ordered separately to run the drive.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits general-purpose 30-37 kW induction motor control in modular G120 drive cabinets: pumps, fans, compressors, and conveyors where the plant standardizes on a separate power module plus control unit architecture rather than a single-housing inverter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959463960859,"sku":"6SL3210-1PE27-5UL0","price":3833.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe27-5ul0-pm240-2-power-module.png?v=1789678502"},{"product_id":"siemens-6sl3210-1pe28-8ul0-pm240-2-45kw-power-module","title":"Siemens 6SL3210-1PE28-8UL0 SINAMICS G120 PM240-2 45kW IP20 FSE VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE28-8UL0 is a SINAMICS G120 PM240-2 power module rated 45 kW low overload \/ 37 kW high overload at 3AC 380-480V, with a built-in braking chopper and IP20 (frame size FSE) enclosure. It operates without a filter and requires a separate Control Unit, firmware V4.7 HF8 or compatible.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE28-8UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2, without filter, IP20, frame size FSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 to 480 V AC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power, low overload (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW \/ 60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power, high overload (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW \/ 50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current, low overload (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current, high overload (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput frequency, vector control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput frequency, V\/f control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.19 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.083 m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature, LO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature, HO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e551 x 275 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePM240-2 without filter means an external EMC or output filter must be added if long motor cable runs or strict EMC class compliance are required — factor that into the bill of materials. The built-in braking chopper allows a braking resistor to be connected directly without a separate braking unit, useful for cranes, centrifuges, or other applications with regenerative loads. Frame size FSE (551 x 275 x 237 mm, 26.4 kg) sits at the top of the PM240-2 range at this power point; check panel clearance and cooling airflow (0.083 m3\/s) before specifying the enclosure.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePairs with a SINAMICS G120 Control Unit to form a complete drive for fans, pumps, and conveyors up to 45 kW where a compact, filterless power stage with an integrated braking chopper is sufficient.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959464124699,"sku":"6SL3210-1PE28-8UL0","price":4643.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe28-8ul0-pm240-2-45kw-power-module.png?v=1789679578"},{"product_id":"siemens-6sl3210-1pe31-1ul0-pm240-2-55kw-vfd-power-module","title":"Siemens 6SL3210-1PE31-1UL0 SINAMICS G120 PM240-2 3AC 400V 55kW\/45kW VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE31-1UL0 is a SINAMICS G120 PM240-2 power module rated 55 kW low overload \/ 45 kW high overload at 3AC 380-480V, supplied in an IP20 frame size FSE without a filter but with a built-in braking chopper. It delivers up to 180 A maximum output current at a 4 kHz pulse frequency and requires a separate PM240-2 control unit to operate.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE31-1UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V AC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55.00 kW \/ 75.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.00 kW \/ 60.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (Vector Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency (V\/f Control)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.54 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.083 m³\/s airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20, frame size FSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e551 x 275 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis PM240-2 has an integrated braking chopper but no line filter - add an external EMC filter if the installation needs conducted-emission compliance, since the filtered PM240-2 variants in the same frame carry one built in. Rate the load against the low-overload figures (55 kW \/ 104 A) for continuous variable-torque duty such as pumps and fans, and against the high-overload figures (45 kW \/ 94 A) for constant-torque duty like conveyors and extruders that need 150% for 57 s. This power module needs a matching PM240-2 control unit - it has no onboard I\/O or fieldbus interface of its own.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a modular SINAMICS G120 drive for pump, fan, and conveyor applications at 380-480 V, where the built-in braking chopper handles regenerative energy from decelerating loads without a separate braking module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959464288539,"sku":"6SL3210-1PE31-1UL0","price":5344.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe31-1ul0-pm240-2-vfd-power-module.png?v=1789679584"},{"product_id":"siemens-6sl3210-1pe31-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE31-5UL0 SINAMICS G120 PM240-2 Power Module 75kW IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PE31-5UL0 is a SINAMICS G120 PM240-2 power module rated 75.00 kW (low overload) or 55.00 kW (high overload) on a 3AC 380-480V supply, with a built-in braking chopper and IP20 protection in frame size FSF. It runs without a filter and requires a separate Control Unit and operator panel.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE31-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V plus\/minus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power, low overload (LO)\u003c\/td\u003e\n\u003ctd\u003e75.00 kW \/ 100.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power, high overload (HO)\u003c\/td\u003e\n\u003ctd\u003e55.00 kW \/ 75.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, low overload (LO)\u003c\/td\u003e\n\u003ctd\u003e140.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, high overload (HO)\u003c\/td\u003e\n\u003ctd\u003e117.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, low overload (LO), alt. rating\u003c\/td\u003e\n\u003ctd\u003e145.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current, high overload (HO), alt. rating\u003c\/td\u003e\n\u003ctd\u003e110.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e220.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.78 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.153 m3\/s (5.403 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation, low overload (LO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation, high overload (HO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP20, frame size FSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e58.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe low-overload rating of 75.00 kW (140.00 A) covers loads such as pumps and fans that run near continuous full load, while the high-overload rating of 55.00 kW (117.00 A) is the figure to check for applications with 150% overload spikes for 57 s, such as conveyors or extruders. The 220.00 A max. output current sets the ceiling for short-duration current spikes on either rating. This module ships without a filter and needs a Control Unit and operator panel added separately, so it fits builds that reuse an existing CU or want to select filter class independently. Frame size FSF and IP20 protection mean it belongs inside a cabinet, not on an open panel.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePumps, fans, conveyors, and extruders in the 55-75 kW range on a 380-480 V supply, built up as a modular SINAMICS G120 drive with a separately ordered Control Unit and BOP\/IOP operator panel, inside a ventilated IP20-rated enclosure.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959464419611,"sku":"6SL3210-1PE31-5UL0","price":6424.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe31-5ul0-pm240-2-power-module-vfd.png?v=1789680179"},{"product_id":"siemens-6sl3210-1ph21-4ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH21-4UL0 SINAMICS G120 PM240-2 7.5kW\/11kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH21-4UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 7.50 kW at high overload and 11.00 kW at low overload in the FSD frame. A braking chopper is built in, no input filter is fitted, and the module ships without a control unit or operator panel; it is approved from CU firmware V4.7 HF8. At 17.4 kg and IP20-rated, it fits a 472 x 200 x 237 mm cabinet footprint on 690V industrial distribution.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH21-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e472 x 200 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e14.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e11.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 7.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e22.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.32 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operation humidity\u003c\/td\u003e\n\u003ctd\u003e95 % RH, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 500-690V, this module connects directly to 690V industrial distribution, unlike the lower-voltage PM240-2 frame sizes built for 200-240V supply. Within the FSD frame, 7.50 kW \/ 11.00 kW is the lowest power point offered in this batch, so it fits pumps and fans whose overload demand stays close to the low-overload rating rather than machines needing sustained torque near the frame's upper current limit. The built-in braking chopper covers occasional regenerative events without an added braking module, screw-type terminals simplify field wiring versus spring-clamp alternatives.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959464550683,"sku":"6SL3210-1PH21-4UL0","price":1539.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph21-4ul0-pm240-2-vfd-power-module.png?v=1790181463"},{"product_id":"siemens-6sl3210-1ph22-0ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH22-0UL0 SINAMICS G120 PM240-2 11kW\/15kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH22-0UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 11.00 kW at high overload and 15.00 kW at low overload in the FSD frame. It has an integrated braking chopper, ships unfiltered and without a control unit or operator panel, and is approved from CU firmware V4.7 HF8. Net weight is 17.4 kg with IP20 protection in the same 472 x 200 x 237 mm FSD enclosure used across this power step.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH22-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e472 x 200 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e18.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e14.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e15.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e19.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e29.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.41 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBetween the 7.50 kW and 18.50 kW FSD variants, this 11.00 kW \/ 15.00 kW step covers motors that outgrow the smallest FSD module without moving up to the larger FSE frame. Max. output current of 29.00 A gives roughly 50% headroom above the 19.00 A rated output current, which is the margin the drive uses to ride through the 200% \/ 3 s overload window rather than trip. The braking chopper is built in, so occasional regenerative loads do not need a separate braking module in this frame size.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959465238811,"sku":"6SL3210-1PH22-0UL0","price":2021.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph22-0ul0-pm240-2-vfd-power-module.png?v=1790181469"},{"product_id":"siemens-6sl3210-1ph22-3ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH22-3UL0 SINAMICS G120 PM240-2 15kW\/18.5kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH22-3UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 15.00 kW at high overload and 18.50 kW at low overload in the FSD frame. The module integrates a braking chopper, has no input filter, and ships without a control unit or operator panel; it runs from CU firmware V4.7 HF8. It weighs 17.4 kg with IP20 protection in the 472 x 200 x 237 mm FSD frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH22-3UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e472 x 200 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e22.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e20.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e18.50 kW \/ 20.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e15.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e23.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e19.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e38.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.48 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the top of the mid-range FSD lineup in this batch before stepping up to the FSE frame at 37.00 kW low-overload; pick it over the 11.00 kW \/ 15.00 kW module when the driven load's continuous current draw is closer to 23.00 A than to 19.00 A. Max. output current of 38.00 A gives headroom for the 200% \/ 3 s overload window on high-overload duty, which matters for machines with high breakaway torque, such as positive-displacement pumps. Since the module ships unfiltered, plan for an external EMC filter if conducted-emission limits apply to the installation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959465402651,"sku":"6SL3210-1PH22-3UL0","price":2483.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph22-3ul0-pm240-2-vfd-power-module.png?v=1790181475"},{"product_id":"siemens-6sl3210-1ph22-7ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PH22-7UL0 SINAMICS G120 PM240-2 IP20 FSD 690V 22kW VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH22-7UL0 is a SINAMICS G120 PM240-2 power module in IP20 FSD frame, rated 22 kW low-overload (18.5 kW high-overload) for a 3 AC 500-690 V line supply, delivering up to 46 A output current. Internal air cooling and a built-in braking chopper support the 27.00 A continuous output rating without an external filter.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH22-7UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e25.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e24.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e22.00 kW (25.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e18.50 kW (20.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e27.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e23.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e46.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.56 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m3\/s (1.942 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 22.00 kW LO \/ 18.50 kW HO split means this module carries more overload margin at the HO rating (200% for 3s) for high-inertia starts, while the LO rating (150% for 60s) suits steady loads run closer to full power. The 500-690 V input covers medium-voltage industrial distribution without a step-down transformer - verify the site supply falls within this class before ordering, since lower-voltage PM240-2 variants in the same family are not interchangeable across voltage classes. At 2 kHz pulse frequency, lower than smaller-frame PM240-2 units, expect more audible motor noise but lower switching losses at this power level.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSized for medium-voltage 500-690 V industrial drives - large pumps, fans, and compressors where a 22 kW motor runs directly from a SINAMICS G120 PM240-2 power module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959465533723,"sku":"6SL3210-1PH22-7UL0","price":2856.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph22-7ul0-pm240-2-power-module.png?v=1789681344"},{"product_id":"siemens-6sl3210-1ph23-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PH23-5UL0 SINAMICS PM240-2 30kW 690V FSD VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH23-5UL0 is a SINAMICS PM240-2 power module without a filter, built for a 3AC 500-690 V ±10% supply and rated 30 kW \/ 33.00 A at low overload or 22 kW \/ 28.00 A at high overload. It has a built-in braking chopper, frame size FSD, IP20 degree of protection, and weighs 17.4 kg. It is supplied without a control unit or operator panel.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH23-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVFD Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (LO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW (30.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power (HO)\u003c\/td\u003e\n\u003ctd\u003e22.00 kW (25.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (LO)\u003c\/td\u003e\n\u003ctd\u003e33.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (HO)\u003c\/td\u003e\n\u003ctd\u003e28.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e54.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC \/ 600 V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (Vector Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (V\/f Control)\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.72 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling, 0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Chopper\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 690 V rating (600 V NEC) is the key differentiator on this PM240-2: it covers 500-690 V lines, above the more common 380-480 V PM240-2 variants, so confirm supply voltage before ordering. Sizing splits into low overload (LO, 30 kW \/ 33.00 A, for variable-torque loads like pumps and fans with light overload duty) and high overload (HO, 22 kW \/ 28.00 A, for constant-torque loads needing 150% for 57 s \/ 200% for 3 s per the catalog's HO overload profile). The built-in braking chopper handles dynamic braking energy without an external braking module, and the FSD frame ships without a control unit, so a separate CU240 control unit is required to operate it.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed in SINAMICS G120 modular VFD assemblies on 690 V lines — common in mining, cement, and heavy material-handling plants — for pump, fan, and conveyor loads sized between 22 kW and 30 kW depending on the duty's overload profile.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959465730331,"sku":"6SL3210-1PH23-5UL0","price":3601.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph23-5ul0-sinamics-pm240-2-power-module.png?v=1789715140"},{"product_id":"siemens-6sl3210-1ph24-2ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH24-2UL0 SINAMICS G120 PM240-2 30kW\/37kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH24-2UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 30.00 kW at high overload and 37.00 kW at low overload in the FSD frame. It has a built-in braking chopper, no input filter, and ships without a control unit or operator panel, running from CU firmware V4.7 HF8. At 17.4 kg with IP20 protection, it is the largest module built into the 472 x 200 x 237 mm FSD enclosure in this power range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH24-2UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e472 x 200 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e40.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e36.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW \/ 30.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e42.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e35.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e70.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.88 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the highest-power FSD variant in this batch before the next size up moves to the larger FSE frame at 45.00 kW low-overload; choose it when the load's continuous current sits near 42.00 A output rather than the 35.00 A figure that matches lighter, high-overload duty. Max. output current of 70.00 A is roughly double the rated output current, the margin the module draws on during the 200% \/ 3 s overload window. Power loss of 0.88 kW at this rating is the largest in the FSD group, so cabinet ventilation sizing should account for it rather than reusing the figure from a smaller module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959465894171,"sku":"6SL3210-1PH24-2UL0","price":4408.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph24-2ul0-pm240-2-vfd-power-module.png?v=1790181482"},{"product_id":"siemens-6sl3210-1ph25-2ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH25-2UL0 SINAMICS G120 PM240-2 37kW\/45kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH25-2UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 37.00 kW at high overload and 45.00 kW at low overload in the FSE frame. A braking chopper is built in, the module ships unfiltered and without a control unit or operator panel, and it is approved from CU firmware V4.7 HF8. It weighs 27.1 kg, carries IP20 protection, and measures 551 x 275 x 237 mm.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH25-2UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e551 x 275 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e50.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e44.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e45.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e52.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e42.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e84.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.083 m³\/s (2.931 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e27.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eStepping up from the FSD frame's 37.00 kW low-overload ceiling, this is the entry point of the FSE range in this batch; pick it once the driven load's continuous current exceeds the FSD frame's 70.00 A max. output current. Cooling air requirement rises to 0.083 m³\/s here, so cabinet airflow planning should use this figure rather than the smaller FSD value once frame size changes. The integrated braking chopper still covers occasional regeneration without an external braking module, though sustained regenerative duty on a 45 kW load needs a dedicated resistor sized for it.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466025243,"sku":"6SL3210-1PH25-2UL0","price":5339.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph25-2ul0-pm240-2-vfd-power-module.png?v=1790181488"},{"product_id":"siemens-6sl3210-1ph26-2ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH26-2UL0 SINAMICS G120 PM240-2 45kW\/55kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH26-2UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 45.00 kW at high overload and 55.00 kW at low overload in the FSE frame. It has an integrated braking chopper, no input filter, and ships without a control unit or operator panel; it is approved from CU firmware V4.7 HF8. Net weight is 27.1 kg, protection is IP20, and dimensions match the FSE frame at 551 x 275 x 237 mm.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH26-2UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e551 x 275 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e59.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e54.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e55.00 kW \/ 60.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e45.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e62.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e52.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e104.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.21 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.083 m³\/s (2.931 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e27.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the largest FSE-frame module in this batch before the next step moves to the FSF frame at 75.00 kW low-overload; choose it over the 37.00 kW \/ 45.00 kW FSE variant when continuous current draw runs closer to 62.00 A than 52.00 A. Power loss of 1.21 kW is the highest figure in the FSE group, so it drives the cabinet's heat-dissipation sizing more than the frame's physical size does. The braking chopper is built in, handling occasional regeneration without an external module, though at 55 kW a dedicated braking resistor is still needed for continuous regenerative duty.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466221851,"sku":"6SL3210-1PH26-2UL0","price":6147.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph26-2ul0-pm240-2-vfd-power-module.png?v=1790181495"},{"product_id":"siemens-6sl3210-1ph28-0ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH28-0UL0 SINAMICS G120 PM240-2 55kW\/75kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH28-0UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 55.00 kW at high overload and 75.00 kW at low overload in the FSF frame. It has a built-in braking chopper, ships unfiltered and without a control unit or operator panel, and runs from CU firmware V4.7 HF8. At 61.0 kg with IP20 protection and a 708 x 305 x 357 mm footprint, it opens the FSF frame size in this power range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH28-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e708 x 305 x 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e78.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e66.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e75.00 kW \/ 75.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e55.00 kW \/ 60.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e80.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e62.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e124.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.153 m³\/s (5.403 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e61.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the entry point of the FSF frame in this batch, stepping up from the FSE frame's 55.00 kW low-overload ceiling; select it once continuous current exceeds the FSE frame's 104.00 A max. output current. Max. output current here reaches 124.00 A against an 80.00 A output rated current, keeping the same roughly 50% overload margin used across the smaller frames for the 200% \/ 3 s window. Net weight jumps to 61.0 kg with this frame change, a factor for panel and lifting-hardware sizing that the FSD and FSE frames do not require.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466615067,"sku":"6SL3210-1PH28-0UL0","price":7388.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph28-0ul0-pm240-2-vfd-power-module.png?v=1790181502"},{"product_id":"siemens-6sl3210-1ph31-0ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH31-0UL0 SINAMICS G120 PM240-2 75kW\/90kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH31-0UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 75.00 kW at high overload and 90.00 kW at low overload in the FSF frame. A braking chopper is integrated, the module ships unfiltered and without a control unit or operator panel, and it is approved from CU firmware V4.7 HF8. It weighs 61.0 kg, carries IP20 protection, and shares the 708 x 305 x 357 mm FSF footprint used across this power step.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH31-0UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e708 x 305 x 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e97.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e85.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e90.00 kW \/ 100.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e75.00 kW \/ 75.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e100.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e80.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e160.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.153 m³\/s (5.403 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e61.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBetween the 55.00 kW and 90.00 kW FSF variants, this 75.00 kW \/ 90.00 kW module suits motors that outgrow the smallest FSF size without needing the top rating in this line. Output rated current of 100.00 A against a 160.00 A max. output current preserves the frame's usual overload margin for the 200% \/ 3 s window. Power loss of 1.55 kW is noticeably higher than the entry FSF module's 1.22 kW, so cabinet cooling calculations should use this module's own figure rather than reusing the smaller unit's value.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466746139,"sku":"6SL3210-1PH31-0UL0","price":8630.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph31-0ul0-pm240-2-vfd-power-module.png?v=1790181508"},{"product_id":"siemens-6sl3210-1ph31-2ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH31-2UL0 SINAMICS G120 PM240-2 90kW\/110kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH31-2UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 90.00 kW at high overload and 110.00 kW at low overload - the highest power step in this FSF frame line. It has a built-in braking chopper, ships unfiltered and without a control unit or operator panel, and is approved from CU firmware V4.7 HF8. It weighs 61.0 kg with IP20 protection in a 708 x 305 x 357 mm enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH31-2UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668368\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e708 x 305 x 357 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e111.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e106.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e110.00 kW \/ 100.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e90.00 kW \/ 100.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e115.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e100.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e200.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.82 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.153 m³\/s (5.403 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e61.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the top of the FSF range and the highest-power PM240-2 module in this line; pick it over the 75.00 kW \/ 90.00 kW module once continuous output current needs to reach closer to 115.00 A than 100.00 A. Max. output current of 200.00 A keeps the frame's overload margin for the 200% \/ 3 s window even at this rating. Power loss reaches 1.82 kW, the highest in the FSF group, so it sets the upper bound for cabinet ventilation sizing across this entire PM240-2 power module range.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466877211,"sku":"6SL3210-1PH31-2UL0","price":9748.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph31-2ul0-pm240-2-vfd-power-module.png?v=1790181515"},{"product_id":"siemens-6sl3210-1ph31-4ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH31-4UL0 SINAMICS G120 PM240-2 690V 132kW FSF VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH31-4UL0 is a SINAMICS G120 Power Module PM240-2 in frame size FSF with a built-in braking chopper, rated 500-690V 3AC input at 47-63Hz. Low-overload power reaches 132.00kW and high-overload power 110.00kW, with a maximum output current of 230.00A and IP20 protection without a control unit or panel fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH31-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e137.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e122.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e132.00 kW \/ 125.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e110.00 kW \/ 100.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e142.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e115.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e230.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e2.33 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.153 m3\/s (5.403 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e61.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 500-690V input rating covers 690V three-phase networks that fall outside the standard 380-480V PM240-2 range, avoiding a separate step-down transformer. The built-in braking chopper switches an external resistor directly, useful for winders, cranes, and other fast-decelerating loads without a bolt-on braking module. At 132.00kW (LO) \/ 110.00kW (HO) in frame FSF, this sits at the top of the PM240-2 range - the HO rating with 200% overload for 3s fits load profiles with brief torque spikes such as presses, while the LO rating with only 150% overload suits steadier centrifugal loads such as large pumps and fans.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eVariable-speed control of 3-phase induction motors up to 132kW (LO) or 110kW (HO) on 500-690V supplies, in modular SINAMICS G120 drive assemblies for large pumps, fans, and heavy machine axes where a separate braking resistor absorbs regenerated energy.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467041051,"sku":"6SL3210-1PH31-4UL0","price":10865.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph31-4ul0-pm240-2-vfd-power-module.png?v=1790181521"},{"product_id":"siemens-6sl3225-0be25-5aa1-pm250-power-module","title":"Siemens 6SL3225-0BE25-5AA1 SINAMICS G120 PM250 FSC 5.5kW 400V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE25-5AA1 is a SINAMICS G120 Power Module PM250 in frame size FSC with an integrated Class A EMC filter and energy-recovery capability, rated 380-480V 3AC input at 47-63Hz. Low-overload power is 7.50kW and high-overload power 5.50kW, with a maximum output current of 26.40A and IP20 protection without control unit fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE25-5AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e18.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e13.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e5.50 kW \/ 7.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e26.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.038 m3\/s (1.342 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 C (32 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal version\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe integrated Class A filter and energy-recovery capability set the PM250 apart from a PM240-2 of similar power - braking energy returns to the supply instead of heating a resistor, which matters for hoists, centrifuges, and other frequently decelerating loads. At 7.50kW (LO) \/ 5.50kW (HO) with an 18.00A rated LO current, this is the smallest FSC-frame PM250 in the range; step up to the next current rating once continuous torque exceeds what this module supports.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 drive for fans, pumps, and small hoists on a 380-480V three-phase supply where regenerative braking reduces resistor heat load. Pairs with a matching Control Unit and BOP display; screw-type terminals are fitted as standard.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467303195,"sku":"6SL3225-0BE25-5AA1","price":1554.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be25-5aa1-pm250-vfd-power-module.png?v=1790181546"},{"product_id":"siemens-6sl3225-0be27-5aa1-pm250-power-module","title":"Siemens 6SL3225-0BE27-5AA1 SINAMICS G120 PM250 FSC 7.5kW 400V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE27-5AA1 is a SINAMICS G120 Power Module PM250 in frame FSC with an integrated Class A EMC filter and energy-recovery capability, rated 380-480V 3AC input at 47-63Hz. Low-overload power is 11.00kW and high-overload power 7.50kW, with a maximum output current of 38.00A and IP20 protection without control unit fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE27-5AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e25.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e19.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e38.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.28 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.038 m3\/s (1.342 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 C (32 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal version\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe Class A filter and energy-recovery capability distinguish this PM250 from a PM240-2 of similar power - braking energy is returned to the supply rather than dissipated in a resistor, relevant for hoists, centrifuges, and other frequently decelerating loads. At 11.00kW (LO) \/ 7.50kW (HO) with a 19.00A rated HO current and 38.00A maximum output, it sits above the 5.5kW FSC variant in the same frame - pick it once the driven load's continuous torque exceeds what the smaller module supports.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 drive for fans, pumps, and hoists on a 380-480V three-phase supply where regenerative braking reduces resistor heat load. Pairs with a matching Control Unit and BOP display; screw-type terminals are fitted as standard.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467467035,"sku":"6SL3225-0BE27-5AA1","price":1962.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be27-5aa1-pm250-vfd-power-module.png?v=1790181552"},{"product_id":"siemens-6sl3225-0be31-1aa1-pm250-power-module","title":"Siemens 6SL3225-0BE31-1AA1 SINAMICS G120 PM250 FSC 11kW 400V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE31-1AA1 is a SINAMICS G120 Power Module PM250 in FSC frame, rated 15.00kW low overload \/ 11.00kW high overload at 380-480V 3AC input, with an integrated Class A EMC filter and energy-recovery capability. Output current reaches 52.00A max at a 4kHz pulse frequency, rated IP20 without Control Unit or BOP.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE31-1AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e32.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e26.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e15.00 kW \/ 20.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 15.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e52.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.31 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.038 m3\/s (1.342 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 C (32 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal version\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe PM250's integrated Class A filter and energy-recovery capability distinguish it from a PM240-2 unit of similar power: braking energy is fed back into the supply instead of dissipated in a resistor, which matters for cranes, centrifuges, or other frequently decelerating loads. At 15.00kW (LO) \/ 11.00kW (HO) with a 26.00A rated HO current and 52.00A maximum output, this module sits at the lower end of the PM250 FSC power range; the Class A filter limits conducted emissions for standard industrial environments but is not sufficient for residential Class B installations.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 drive for fans, pumps, and hoists on a 380-480V three-phase supply where regenerative braking reduces resistor heat load. Pairs with a matching Control Unit and BOP display; screw-type terminals are fitted as standard.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467598107,"sku":"6SL3225-0BE31-1AA1","price":2480.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be31-1aa1-pm250-vfd-power-module.png?v=1789714264"},{"product_id":"siemens-6sl3225-0be31-5aa0-sinamics-g120-pm250-power-module","title":"Siemens 6SL3225-0BE31-5AA0 SINAMICS G120 PM250 380-480V 15kW IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE31-5AA0 is a SINAMICS G120 PM250 power module with a built-in Class A filter and regenerative capability, fed from a 3 AC 380-480 V ±10% line at 47-63 Hz. It delivers 15 kW at high overload (200% for 3 s) or 18.5 kW at light overload, with up to 64 A output current in an IP20 frame size D enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE31-5AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE31-5AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003ePM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e36.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e30.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400 V (IEC) \/ 480 V (NEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e18.50 kW (25.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e15.00 kW (20.00 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e38.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e32.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e64.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.42 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.022 m³\/s (0.777 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation (LO)\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 °C (32 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation (HO)\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 °C (32 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (without control unit and BOP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e512 x 275 x 204 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSize this module on the light-overload (LO) rating, 18.5 kW at 38 A, for continuous-load applications such as pumps and fans that only need 110% for 57 s; use the high-overload (HO) rating, 15 kW at 30-32 A, for loads needing 150% for 57 s and 200% for 3 s, such as conveyors or mixers with starting torque spikes. The built-in Class A filter and regeneration capability let this frame size D module feed energy back to the line during braking without an external braking resistor, which matters for hoist or centrifuge duty cycles with frequent deceleration.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467729179,"sku":"6SL3225-0BE31-5AA0","price":2996.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be31-5aa0-sinamics-g120-pm250-power-module.png?v=1790181558"},{"product_id":"siemens-6sl3225-0be31-8aa0-pm250-power-module","title":"Siemens 6SL3225-0BE31-8AA0 SINAMICS G120 PM250 FSD 18.5kW 400V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE31-8AA0 is a SINAMICS G120 Power Module PM250 in frame FSD with an integrated Class A EMC filter and energy-recovery capability, rated 380-480V 3AC input at 47-63Hz. Low-overload power is 22.00kW and high-overload power 18.50kW, with a maximum output current of 76.00A and IP20 protection without control unit fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE31-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e42.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e36.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e22.00 kW \/ 30.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e18.50 kW \/ 25.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e45.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e38.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e76.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.52 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.022 m3\/s (0.777 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 C (32 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe FSD frame steps up from the FSC modules in current handling - 36.00A rated HO input current and 76.00A maximum output current support motors well beyond the FSC range's top end on the same 380-480V supply. Class A filter and energy-recovery capability carry over from the smaller PM250 modules, so braking energy still returns to the supply instead of heating a resistor. At 22.00kW (LO) \/ 18.50kW (HO), pick the FSD frame over FSC once continuous torque runs past the FSC range.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 drive for larger pumps, fans, and hoists on a 380-480V three-phase supply where regenerative braking reduces resistor heat load. Pairs with a matching Control Unit and BOP display.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467893019,"sku":"6SL3225-0BE31-8AA0","price":3428.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be31-8aa0-pm250-vfd-power-module.png?v=1790181565"}],"url":"https:\/\/stoklink.com\/collections\/vfd-accessories.oembed?page=3","provider":"Stoklink","version":"1.0","type":"link"}