{"title":"Switch Disconnectors \u0026 Transfer Switches","description":"\u003cp\u003eSwitch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/switch-disconnector\"\u003eSwitch Disconnectors\u003c\/a\u003e – load-break isolators for panels and machines, including handles, shafts and interlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/changeover-switch\"\u003eChangeover Switches (Manual \u0026amp; Motorized)\u003c\/a\u003e – select between two supplies, such as mains and generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/automatic-transfer-switches\"\u003eAutomatic Transfer Switches (ATS)\u003c\/a\u003e – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/cam-switch\"\u003eCam Switches\u003c\/a\u003e – Harmony K rotary switches for control, metering and small loads.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.\u003c\/li\u003e\n\u003cli\u003ePole count. Use 4P where the neutral must be switched, for example when changing between two sources.\u003c\/li\u003e\n\u003cli\u003eVoltage and short-circuit withstand. Check the rating against the fault level at the installation point.\u003c\/li\u003e\n\u003cli\u003eControl method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.\u003c\/li\u003e\n\u003cli\u003eMounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between a switch disconnector and a circuit breaker?\u003c\/h3\u003e\u003cp\u003eA switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.\u003c\/p\u003e\u003ch3\u003eWhen should I use an ATS instead of a manual changeover switch?\u003c\/h3\u003e\u003cp\u003eUse an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.\u003c\/p\u003e\u003ch3\u003eDo you ship outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.\u003c\/p\u003e","products":[{"product_id":"abb-1sda073906r1-terminals-term-box-e1-2-e6-2-xt7-m-10pz","title":"ABB 1SDA073906R1 Terminals term.box E1.2..E6.2-XT7\/M 10pz SACE Emax 2 Terminal Box Accessory for Low-Voltage Circuit Breakers","description":"\u003cp\u003eThe ABB 1SDA073906R1 \u003cstrong\u003eTerminals term.box E1.2..E6.2-XT7\/M 10pz\u003c\/strong\u003e is a genuine OEM terminal box accessory designed for SACE Emax 2 series air circuit breakers (E1.2 through E6.2) with XT7\/M configurations. Supplied in a pack of 10 pieces, this low-voltage switch technology spare part ensures secure, reliable terminal connections within Emax 2 installations and is fully compliant with IEC\/UL, CE, and RoHS requirements.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals term.box E1.2..E6.2-XT7\/M 10pz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA073906R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644778392\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories \/ Spare Parts for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax 2 E1.2 to E6.2 (XT7\/M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 × 200 × 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European CE marking requirements for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on the restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Meets updated RoHS 2 requirements including substances added under Amendment 2015\/863\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC \/ UL:\u003c\/strong\u003e Designed and tested in accordance with IEC and UL standards for low-voltage switchgear accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eReplacement terminal box components for SACE Emax 2 E1.2, E2.2, E3.2, E4.2, E6.2 air circuit breakers in XT7\/M configurations\u003c\/li\u003e\n  \u003cli\u003eMaintenance and service kits for industrial power distribution switchboards and motor control centers\u003c\/li\u003e\n  \u003cli\u003eSpare parts inventory management for facility electrical maintenance teams\u003c\/li\u003e\n  \u003cli\u003eNew installation projects requiring compliant, OEM-grade terminal accessories for low-voltage switchgear panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228987101467,"sku":"1SDA073906R1","price":64.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda073906r1-terminals-term-box-e1-2-e6-2-xt7-m-10pz-term-box-e1-2-e6-2-xt7-m-10pz_acd23083-9147-43bb-ba24-79088776bc4b.webp?v=1777184948"},{"product_id":"abb-1sda065523r1-ats021-automatic-transfer-switch-mutli-voltage","title":"ABB 1SDA065523R1 ATS021 Automatic Transfer Switch Mutli Voltage Automatic Transfer Switch","description":"\u003cp\u003eThe ABB 1SDA065523R1, catalog number \u003cstrong\u003eATS021 Automatic Transfer Switch Mutli Voltage\u003c\/strong\u003e, is an automatic transfer switch designed to manage seamless power source changeover in industrial and commercial electrical installations. Part of ABB's Emax series, this ATS021 Automatic Transfer Switch Mutli Voltage unit ensures continuity of supply by automatically switching between available power sources, making it essential for critical load protection and power reliability applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS021 Automatic Transfer Switch Mutli Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA065523R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 110 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.248 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644682033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical equipment safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety (EC No 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic source changeover in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eCritical load protection in data centres, hospitals, and manufacturing facilities\u003c\/li\u003eBackup power switching between mains supply and generator sets\u003cli\u003eMulti-voltage network integration in commercial and industrial automation systems\u003c\/li\u003e\n\u003cli\u003eIntegration with ABB Emax air circuit breakers for complete power management solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991099163,"sku":"1SDA065523R1","price":868.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda065523r1-ats021-automatic-transfer-switch-mutli-voltage-auto-tran-switch-multi-voltage_a2ad5067-fa1f-4da8-b009-c40cd0f9b8b7.webp?v=1777184394"},{"product_id":"abb-1sda065524r1-ats022-auto-tran-switch-advanced-control","title":"ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL Automatic Transfer Switch","description":"\u003cp\u003eThe ABB \u003cstrong\u003eATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL\u003c\/strong\u003e (SKU: 1SDA065524R1) is an automatic transfer switch designed to ensure seamless power source changeover in critical electrical installations. Engineered for advanced control applications, this ABB ATS022 unit delivers reliable, automated switching between primary and backup supplies, protecting sensitive loads from power interruptions. Compact at 160 × 110 × 240 mm and weighing 1.803 kg, it is well-suited for integration into control panels and distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA065524R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS022\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 110 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.803 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644682040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, restricting use of harmful materials in electrical equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on the registration, evaluation, and restriction of chemical substances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomated power source changeover in commercial and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eBackup power management for critical loads and essential circuits\u003c\/li\u003e\n  \u003cli\u003eIntegration with generators and UPS systems for uninterrupted power supply\u003c\/li\u003e\n  \u003cli\u003eControl panel and distribution board installations requiring advanced transfer switching logic\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems where continuous operation is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991164699,"sku":"1SDA065524R1","price":1042.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda065524r1-ats022-auto-tran-switch-advanced-control-auto-tran-switch-advanced-control_face0eb6-4241-405d-9f24-3b9b9074ccaa.webp?v=1777184398"},{"product_id":"abb-2ccg000242r0001-scu100-insite-pro-m-compact-accessory","title":"ABB 2CCG000242R0001 SCU100 InSite Pro M Compact Accessory for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB SCU100 (2CCG000242R0001) is the InSite Pro M Compact accessory and spare part designed for low-voltage switch technology applications. Part of ABB's InSite series, the SCU100 delivers a compact form factor measuring 161 mm × 87 mm × 64.9 mm and weighing just 329 g, making it well suited for integration into control panels and distribution boards where space and weight are critical considerations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCU100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCG000242R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInSite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInSite Pro M Compact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory \/ Spare Part for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e161 mm × 87 mm × 64.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e329 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271508104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union health, safety, and environmental protection standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB SCU100 accessory is intended for use alongside ABB InSite series low-voltage switching devices in industrial automation, motor control centres, control panels, and distribution switchboards. Its compact dimensions and certified compliance make it a reliable choice for procurement engineers sourcing spare parts for maintenance and system upgrades in manufacturing, infrastructure, and building automation environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991230235,"sku":"2CCG000242R0001","price":3286.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccg000242r0001-scu100-abb-2ccg000242r0001-scu100_1d8e60f0-1ed2-4fcf-8b8d-4216d27860d0.webp?v=1777393271"},{"product_id":"abb-2cds200918r0001-s2c-nt-neutral-accessory-s200","title":"ABB 2CDS200918R0001 S2C-NT Hand Operated Neutral Accessory for S200 Series Low-Voltage Circuit Breakers","description":"\u003cp\u003eThe ABB S2C-NT (SKU: 2CDS200918R0001) is a hand-operated neutral accessory designed for use with ABB S200 series low-voltage circuit breakers, enabling precise neutral conductor switching and control in panel assemblies. Rated at 2 W and DIN rail mountable, the S2C-NT delivers reliable performance in industrial control panels, distribution boards, and automation enclosures. With compact dimensions of 8.8 mm × 85 mm × 69 mm and a lightweight 59 g construction, it integrates seamlessly into space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200918R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHand Operated Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory \/ Spare Part for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.059 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779647625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 — addressing the safe use of chemical substances in products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Meets the European RoHS Directive governing hazardous substance restrictions in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with EU Delegated Directive 2015\/863, which updated Annex II of 2011\/65\/EU with additional restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive — supports proper end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNeutral conductor hand operation in S200 series miniature circuit breaker assemblies\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels and distribution boards requiring neutral switching accessories\u003c\/li\u003e\n\u003cli\u003eAutomation enclosures and machine control cabinets with DIN rail infrastructure\u003c\/li\u003e\n\u003cli\u003ePanel builders seeking compact, certified low-voltage switch technology accessories\u003c\/li\u003e\n\u003cli\u003eRetrofit and spare-part replacement for existing ABB S200 series installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020492059,"sku":"2CDS200918R0001","price":11.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200918r0001-s2c-nt-low-voltage-circuit-breakers_0755e6e2-fa46-41e3-b48f-2f8869f6a722.webp?v=1777160961"},{"product_id":"abb-1sca022295r5600-oxp6x150-switch-operating-shaft","title":"ABB 1SCA022295R5600 OXP6X150 6x6x150mm Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXP6X150 (SKU: 1SCA022295R5600) is a switch operating shaft designed for use with ABB enclosed switches and related switchgear assemblies. Measuring 6 x 6 x 150 mm and weighing just 35 grams, this precision-machined shaft transmits rotary motion from an external operator handle to the internal switch mechanism, enabling reliable manual control of switching operations. The OXP6X150 is an essential mechanical interface component for engineers specifying or maintaining ABB switch enclosure solutions in industrial control panels and automation systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP6X150\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022295R5600\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 x 6 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.035 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019141435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances used in electrical components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered and compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMechanical drive shaft for ABB enclosed switch operators and rotary handle mechanisms\u003c\/li\u003e\n  \u003cli\u003eControl panel integration where external door-mounted handles must couple to internal switch actuators\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machinery requiring reliable manual operator interfaces\u003c\/li\u003e\n  \u003cli\u003eReplacement or spare part for existing ABB switchgear installations referencing catalog no. OXP6X150\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229036941595,"sku":"1SCA022295R5600","price":7.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022295r5600-oxp6x150-switch-operating-shaft_4b36bdad-1afb-415e-8640-7d998289c6ed.webp?v=1777157134"},{"product_id":"abb-1sca022295r6080-oxp6x210-shaft-accessory","title":"ABB 1SCA022295R6080 OXP6X210 Shaft 6mm × 6mm × 210mm Rotary Switch Shaft Accessory","description":"\u003cp\u003eThe ABB OXP6X210 (SKU 1SCA022295R6080) is a precision-machined shaft accessory designed for use with ABB rotary and cam switches in industrial control panel applications. With a cross-section of 6 mm × 6 mm and a length of 210 mm, the OXP6X210 shaft provides reliable mechanical coupling between switch actuators and their mounting configurations. Weighing just 57 g, this compact component simplifies panel assembly and ensures consistent actuation performance in demanding automation environments.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP6X210\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022295R6080\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm × 6 mm × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.057 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019141442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable European Union directives for electrical equipment and machinery\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety (EC No 1907\/2006)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMechanical coupling for ABB rotary cam switches and selector switches in control panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machine control enclosures requiring precise shaft-to-actuator alignment\u003c\/li\u003e\n  \u003cli\u003ePanel builders and OEMs sourcing certified ABB switch accessories for BOM-matched assemblies\u003c\/li\u003e\n  \u003cli\u003eReplacement or extension shaft for maintenance and refurbishment of existing ABB switch installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229037007131,"sku":"1SCA022295R6080","price":7.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022295r6080-oxp6x210-switch-shaft-accessory_8a8d966a-7572-4c49-8ad1-0e7972f1a2f3.webp?v=1777157138"},{"product_id":"abb-1sca022325r6980-oxp12x250-switch-operating-shaft","title":"ABB 1SCA022325R6980 OXP12X250 12x12x250mm 0.275kg Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXP12X250 switch operating shaft (SKU 1SCA022325R6980) is a precision-machined mechanical component from ABB's OXP series, designed to transmit rotary motion from an external actuator to a switch disconnector or enclosed switch mechanism. Measuring 12 × 12 × 250 mm and weighing just 0.275 kg, the OXP12X250 provides a robust, direct-drive coupling solution for control panel and switchgear installations requiring extended reach between the operator handle and the switching device.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP12X250\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022325R6980\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 × 12 × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.275 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019141374\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 — addresses the production and use of chemical substances and their potential impacts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with the EU RoHS Directive and its updated substance restrictions under the 2015\/863 amendment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive — supports proper end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eExtended-reach operation of ABB OXP-series switch disconnectors and enclosed switches in deep control panel enclosures\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and motor control centres requiring mechanical shaft extensions between operator and switching device\u003c\/li\u003e\n  \u003cli\u003eMachine control panels and distribution boards where direct front-of-door operation is not feasible\u003c\/li\u003e\n  \u003cli\u003eOEM machinery builds integrating ABB switch disconnectors with custom door-mounted handles\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229037138203,"sku":"1SCA022325R6980","price":11.36,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022325r6980-oxp12x250-abb-1sca022325r6980-oxp12x250_03d82ce8-1442-42f6-a3af-5bfee59932d7.webp?v=1777393407"},{"product_id":"abb-1sda066180r1-kit-din50022-a1-a2-plate-din","title":"ABB 1SDA066180R1 KIT DIN50022 A1-A2 PLATE DIN FORMULA Series DIN Rail Mounting Plate Accessory for Low-Voltage Circuit Breakers","description":"\u003cp\u003eThe ABB \u003cstrong\u003eKIT DIN50022 A1-A2 PLATE DIN\u003c\/strong\u003e (SKU: 1SDA066180R1) is a genuine FORMULA series DIN rail mounting plate accessory designed to securely mount A1 and A2 low-voltage circuit breakers onto standard DIN 50022 profiles. Engineered for industrial control panel installations, this compact mounting kit measures 40 × 250 × 145 mm and weighs just 0.111 kg, making it a lightweight yet robust solution for organised switchgear assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKIT DIN50022 A1-A2 PLATE DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA066180R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFORMULA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\/Spare Parts for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644000820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN 50022 profile mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 × 250 × 145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.111 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, confirming the product is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical safety and substance registration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with applicable IEC standards for low-voltage switch technology accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMounting ABB FORMULA A1 and A2 series air circuit breakers onto standard DIN 50022 rail in industrial control panels.\u003c\/li\u003e\n\u003cli\u003eRetrofitting or replacing mounting hardware in existing switchgear assemblies during maintenance or panel upgrades.\u003c\/li\u003e\n\u003cli\u003eIntegration into motor control centres (MCCs), distribution boards, and automation cabinets requiring organised DIN rail layouts.\u003c\/li\u003e\n\u003cli\u003eSpare part stocking for facilities maintaining ABB FORMULA series circuit breaker installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229045068059,"sku":"1SDA066180R1","price":12.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda066180r1-kit-din50022-a1-a2-plate-din-low-voltage-circuit-breakers_05c8380c-e5cc-45fb-ab58-01f3b53f0e21.webp?v=1777157844"},{"product_id":"abb-1sda105124r1-mir-p-x-xt5-p-w-630a-fp-mechanic-interlock","title":"ABB 1SDA105124R1 MIR-P x XT5 P\/W 630A FP Mechanic Interlock for Switch Tmax XT","description":"\u003cp\u003eThe ABB 1SDA105124R1 \u003cstrong\u003eMIR-P x XT5 P\/W 630A FP\u003c\/strong\u003e is a mechanical interlock accessory designed for ABB Tmax XT5 series plug-in and withdrawable circuit breakers rated up to 630A, preventing simultaneous closure of two switching devices and ensuring safe, reliable operation in industrial control panels. Part of the ABB Tmax XT \/ SACE Tmax XT accessory range, the MIR-P x XT5 P\/W 630A FP delivers robust interlocking for applications where mutual exclusion between switching devices is a critical safety requirement.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIR-P x XT5 P\/W 630A FP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA105124R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT \/ SACE Tmax XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIR-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanic interlock for switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breaker Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x 250 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8056221027540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Compliant with the international standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMutual interlocking between two Tmax XT5 plug-in or withdrawable circuit breakers in switchboards\u003c\/li\u003e\n\u003cli\u003eMain\/standby power source changeover panels requiring hardware-level mutual exclusion\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and motor control centres (MCCs) where simultaneous switching is prohibited\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution boards in manufacturing, utilities, and infrastructure installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229093826843,"sku":"1SDA105124R1","price":31.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda105124r1-mir-p-x-xt5-p-w-630a-fp-switch-tmax-xt_a3b309a6-b22d-4bcc-83ba-a60ccc86c980.webp?v=1777159464"},{"product_id":"abb-1sda105123r1-mir-p-x-xt5-p-w-400a-fp-mechanic-interlock","title":"ABB 1SDA105123R1 MIR-P x XT5 P\/W 400A FP Mechanic Interlock for Switch Tmax XT5 200x250x10mm","description":"\u003cp\u003eThe ABB 1SDA105123R1 MIR-P x XT5 P\/W 400A FP is a mechanical interlock accessory engineered for ABB Tmax XT5 series plug-in and withdrawable circuit breakers rated up to 400A. Designed to prevent simultaneous closing of two circuit breakers, the MIR-P x XT5 P\/W 400A FP ensures safe interlocking in source changeover and bus-tie applications in industrial control panels. Compact at 200 × 250 × 10 mm and weighing 2.7 kg, it integrates directly with XT5 frames for a reliable mechanical solution.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIR-P x XT5 P\/W 400A FP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA105123R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT \/ XT5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMIR-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanic interlock for switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in \/ Withdrawable (P\/W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 × 250 × 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8056221027533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU Low Voltage and EMC Directives for sale within the European Economic Area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Designed and tested in accordance with IEC 60947-2, the international standard for low-voltage circuit-breakers and their accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive (2011\/65\/EU), restricting use of hazardous materials in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Conforms to EU REACH regulation (EC No 1907\/2006) regarding the safe use of chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSource changeover interlocking between two Tmax XT5 circuit breakers in industrial switchboards\u003c\/li\u003e\n\u003cli\u003eBus-tie protection in main and sub-distribution panels to prevent parallel feed conflicts\u003c\/li\u003e\n\u003cli\u003eGenerator changeover systems requiring proven mechanical interlock between mains and standby breakers\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and motor control centers where simultaneous breaker closure must be mechanically prohibited\u003c\/li\u003e\n\u003cli\u003eControl panel assemblies demanding IEC 60947-2 compliant accessory integration with XT5 P\/W frames\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229093892379,"sku":"1SDA105123R1","price":31.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda105123r1-mir-p-x-xt5-p-w-400a-fp-tmax-xt5-200x250x10mm_f88021e5-47cb-4d3c-ae02-0323f00c029e.webp?v=1777159460"},{"product_id":"abb-1sda054922r1-adp-6pin-aux-t4-t5-t6-p-w","title":"ABB 1SDA054922R1 ADP 6pin AUX T4-T5-T6 P\/W Auxiliary Adapter Accessory for SACE Tmax T4 T5 T6 Circuit Breakers","description":"\u003cp\u003eThe ABB 1SDA054922R1 \u003cstrong\u003eADP 6pin AUX T4-T5-T6 P\/W\u003c\/strong\u003e is a factory-certified auxiliary adapter accessory from the SACE Tmax T series, designed to provide 6-pin auxiliary connectivity for ABB Tmax T4, T5, and T6 moulded case circuit breakers in plug-in and withdrawable (P\/W) configurations. Compact at 110 × 140 × 60 mm and weighing just 0.04 kg, this spare part ensures seamless integration into existing Tmax T4\/T5\/T6 assemblies for control panel and switchboard applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADP 6pin AUX T4-T5-T6 P\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA054922R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Tmax T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644557065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\/spare parts for low-voltage switch technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax T4, T5, T6 (Plug-in\/Withdrawable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-pin AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 × 140 × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements for low-voltage electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Compliant with relevant International Electrotechnical Commission standards for low-voltage switch accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) governing chemical substances in electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for proper end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eADP 6pin AUX T4-T5-T6 P\/W\u003c\/strong\u003e is used wherever Tmax T4, T5, or T6 circuit breakers require auxiliary signal connections in plug-in or withdrawable mounting arrangements. Typical applications include industrial distribution boards, motor control centers (MCCs), switchgear panels, and building automation systems where auxiliary contact wiring must be maintained during breaker withdrawal or replacement. The 6-pin configuration supports auxiliary status, signalling, and control wiring without modification to the primary power circuit.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229110112539,"sku":"1SDA054922R1","price":20.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda054922r1-adp-6pin-aux-t4-t5-t6-p-w-aux-t4-t5-t6-p-w_fbc41282-6942-4001-845a-b4573acadef2.webp?v=1777393810"},{"product_id":"abb-1sbn050010r1000-rv5-50-surge-suppressor","title":"ABB 1SBN050010R1000 RV5\/50 24-50V AC\/DC Clip-On Surge Suppressor Accessory for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB RV5\/50 (SKU: 1SBN050010R1000) is a clip-on surge suppressor accessory designed for low-voltage switch technology, rated for 24–50 V AC (50\/60 Hz) or 24–50 V DC. Engineered to protect contactors and control relays from voltage transients and switching surges, the RV5\/50 snaps directly onto compatible ABB devices without additional wiring tools. Its compact footprint — 30.25 mm × 10.5 mm × 32.4 mm and only 15 g — makes it ideal for space-constrained control panel installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRV5\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN050010R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRV5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurge Suppressor Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–50 V AC 50\/60 Hz or 24–50 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClip-on\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.25 mm × 10.5 mm × 32.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471522121325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union electrical equipment directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with updated EU RoHS II Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO. 60947-5-1-14:\u003c\/strong\u003e Canadian Standards Association certified to IEC 60947-5-1 for low-voltage control circuit devices and switching elements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eSurge suppression on ABB contactors and control relays operating at 24–50 V AC\/DC coil voltages\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies in industrial automation and machine building\u003c\/li\u003e\n  \u003cli\u003eProtection against inductive switching transients in motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC control systems requiring low-voltage coil surge protection\u003c\/li\u003e\n  \u003cli\u003eOEM panel builders seeking quick clip-on installation without additional wiring\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229121384731,"sku":"1SBN050010R1000","price":12.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn050010r1000-rv5-50-low-voltage-switch-technology_bfbad3a1-d170-457a-a613-574cc4b1b07f.jpg?v=1777157095"},{"product_id":"abb-1sbn031005t1000-vm3-mechanical-interlock-unit","title":"ABB 1SBN031005T1000 VM3 Mechanical Interlock Unit Mechanic Interlock for Switch","description":"\u003cp\u003eThe ABB VM3 Mechanical Interlock Unit (SKU: 1SBN031005T1000) is a precision-engineered interlock accessory designed to prevent simultaneous engagement of two contactors or switching devices in industrial control panel applications. The VM3 ensures safe, mutually exclusive switching by mechanically linking two units, eliminating the risk of hazardous parallel operation. Compact and lightweight at just 0.002 kg, it integrates seamlessly into automation and motor control assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN031005T1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical Interlock Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.002 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6975486359352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical equipment safety and electromagnetic compatibility\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for products placed on the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemicals safety (EC 1907\/2006)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO. 60947-5-1-14:\u003c\/strong\u003e Certified to Canadian Standards Association standard for low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment compliant — supports responsible end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eReversing motor starter circuits requiring mutually exclusive forward\/reverse contactor operation\u003c\/li\u003e\n  \u003cli\u003eStar-delta starter assemblies in industrial motor control panels\u003c\/li\u003e\n  \u003cli\u003eAny dual-contactor application in automation systems where simultaneous closure must be physically prevented\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies in manufacturing, HVAC, and process automation environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229121777947,"sku":"1SBN031005T1000","price":8.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn031005t1000-vm3-interlock-for-switch_e9a6cf65-6c74-41d5-b470-77afa5ed3662.webp?v=1777157090"},{"product_id":"abb-1sbn050010r1002-rv5-250-surge-suppressor","title":"ABB 1SBN050010R1002 RV5\/250 Surge Suppressor 110-250V AC\/DC Clip-On Accessories\/Spare Parts for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB RV5\/250 Surge Suppressor (SKU: 1SBN050010R1002) is a clip-on accessory designed for low-voltage switch technology, providing reliable transient voltage suppression across a rated voltage range of 110–250V AC (50\/60Hz) and 110–250V DC. Purpose-built for use with ABB contactors and relays, the RV5\/250 protects coils and sensitive control circuits from voltage spikes and electromagnetic interference in industrial automation and control panel applications. Its compact clip-on design enables fast, tool-free installation without additional wiring.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRV5\/250\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN050010R1002\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRV5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurge Suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–250V AC 50\/60Hz \/ 110–250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClip-on\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.25 mm × 10.5 mm × 32.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471522121349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant with UK market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Updated EU RoHS Directive 2011\/65\/EU compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — responsible end-of-life disposal compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO. 60947-5-1-14:\u003c\/strong\u003e Canadian Standards Association — low-voltage switchgear and controlgear standard for control circuit devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCoil surge suppression on ABB contactors and control relays in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of PLC outputs and automation controllers from inductive switching transients\u003c\/li\u003e\n  \u003cli\u003eMotor control centres (MCC) where coil switching generates voltage spikes\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC control systems using 110–250V AC or DC control circuits\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor control applications requiring enhanced electrical noise suppression\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229122007323,"sku":"1SBN050010R1002","price":12.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn050010r1002-rv5-250-low-voltage-switch-technology_247b3f0a-16be-4ab3-997e-3bc62d16956b.jpg?v=1777157099"},{"product_id":"abb-1sbn081006t1000-bea16-3-connecting-link","title":"ABB 1SBN081006T1000 BEA16-3 Connecting Link with Manual Motor Starter Low-Voltage Switch Technology Accessory","description":"\u003cp\u003eThe ABB BEA16-3 (SKU: 1SBN081006T1000) is a connecting link accessory designed for use with ABB manual motor starters in low-voltage switch technology applications. Part of the BEA16 series, this compact component measures 45 × 37 × 57.3 mm and weighs just 19 g, making it an easy-fit spare part for control panel assemblies and motor protection circuits.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA16-3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN081006T1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\/spare parts for low-voltage switch technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting Link with Manual Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 × 37 × 57.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.019 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6975486359369\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO. 60947-5-1-14:\u003c\/strong\u003e Canadian Standards Association certification for low-voltage switchgear and control devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting link between ABB manual motor starters and associated accessories in low-voltage switch technology panels\u003c\/li\u003e\n  \u003cli\u003eControl panel assembly and motor protection circuit configurations\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machine control cabinets\u003c\/li\u003e\n  \u003cli\u003eReplacement spare part for existing BEA16 series installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229124628763,"sku":"1SBN081006T1000","price":12.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn081006t1000-bea16-3-switch-technology-accessory_3835787e-d329-4e7f-a4ea-097cbf29d0d6.jpg?v=1777157104"},{"product_id":"abb-1sbn030111r1000-vem4-mechanical-electrical-interlock","title":"ABB 1SBN030111R1000 VEM4 Mechanical and Electrical Interlock Set 2P Mechanic Interlock for Switch","description":"\u003cp\u003eThe ABB VEM4 (1SBN030111R1000) is a Mechanical and Electrical Interlock Set designed to prevent simultaneous operation of two contactors or switches, ensuring safe and reliable interlocking in industrial control panels. The VEM4 is a 2-pole interlock accessory with a compact footprint of 25 mm × 43 mm × 31.6 mm and a lightweight 35 g construction, making it ideal for space-constrained switchgear installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVEM4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN030111R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVEM4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical and Electrical Interlock Set\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm × 43 mm × 31.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.035 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with the updated RoHS II Directive 2011\/65\/EU including Annex II\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e European harmonised standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European harmonised standard for enclosure protection (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for the Canadian market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-1-13:\u003c\/strong\u003e CSA standard for low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:\u003c\/strong\u003e CSA standard for contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA general compliance with the 60947 switchgear and controlgear family\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eInterlocking two contactors to prevent simultaneous energisation in reversing starter circuits\u003c\/li\u003e\n  \u003cli\u003eStar-delta motor starter panels requiring mechanical safety interlock between main and delta contactors\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and motor control centres (MCC) where dual-contactor switching is required\u003c\/li\u003e\n  \u003cli\u003eAutomation systems demanding IEC 60947-5 compliant interlock accessories\u003c\/li\u003e\n  \u003cli\u003eOEM machine builders requiring compact, lightweight interlock solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229143798043,"sku":"1SBN030111R1000","price":13.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn030111r1000-vem4-interlock-for-switch_d286d9db-5ac7-46cd-9bba-2a9901d67310.webp?v=1777157086"},{"product_id":"abb-1sbn082306t1000-bea26-4-connecting-link","title":"ABB 1SBN082306T1000 BEA26-4 Connecting Link with Manual Motor Starter 690V AC Accessory","description":"\u003cp\u003eThe ABB BEA26-4 (SKU: 1SBN082306T1000) is a connecting link accessory designed for use with manual motor starters, rated up to 690 V AC and part of ABB's BEA series of low-voltage switch technology accessories. Compact and lightweight at just 25 g with dimensions of 45 × 48 × 41.8 mm, the BEA26-4 simplifies mechanical and electrical interconnection in motor control assemblies, meeting global certifications including UL, CSA, CE, and RoHS for deployment in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA26-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN082306T1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA26-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting Link with Manual Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 × 48 × 41.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.025 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL certification for low-voltage switchgear and controlgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian Standards Association certification for low-voltage motor starters and contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e General CSA C22.2 series compliance for electrical equipment in Canada\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA group certified for use in North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant for responsible end-of-life disposal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229145731355,"sku":"1SBN082306T1000","price":8.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn082306t1000-bea26-4-690v-ac-accessory_44d4cf2f-f358-4c02-8250-2268634e86fd.webp?v=1777157112"},{"product_id":"abb-1sfn035700r1000-vm750h-mechanical-interlock-switch","title":"ABB 1SFN035700R1000 VM750H Mechanical Interlock Unit Mechanic Interlock for Switch 123.8x52x70mm","description":"\u003cp\u003eThe ABB VM750H (1SFN035700R1000) is a mechanical interlock unit designed to prevent simultaneous operation of two switching devices, ensuring safe and reliable control panel configurations. Horizontally mounted and compact at 123.8 x 52 x 70 mm, the VM750H integrates seamlessly into ABB switch assemblies and is trusted by engineers and panel builders in industrial automation and power distribution applications. Weighing just 0.2 kg, this interlock unit offers a straightforward, robust solution for mutual exclusion switching logic.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM750H\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFN035700R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM750H\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical Interlock Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.8 x 52 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500222102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant — free from restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMutual exclusion interlocking between two contactors or switch devices in motor control panels\u003c\/li\u003e\n  \u003cli\u003eReversing starter circuits requiring mechanical prevention of simultaneous energisation\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels where dual-source or changeover switching is employed\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor control systems requiring reliable interlock safety mechanisms\u003c\/li\u003e\n  \u003cli\u003ePanel builders integrating ABB switching devices requiring factory-aligned mechanical interlock accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the VM750H used for?\u003c\/strong\u003e The VM750H is a mechanical interlock unit that physically prevents two switching devices from being engaged simultaneously, providing a hardware-level safety function in control panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the mounting orientation of the VM750H?\u003c\/strong\u003e The VM750H is designed for horizontal mounting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat are the dimensions of the VM750H?\u003c\/strong\u003e The unit measures 123.8 mm (W) x 52 mm (D) x 70 mm (H) and weighs 0.2 kg.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs the VM750H RoHS compliant?\u003c\/strong\u003e Yes, the ABB VM750H carries REACH, RoHS, and WEEE compliance certifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229145796891,"sku":"1SFN035700R1000","price":55.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfn035700r1000-vm750h-for-switch-123-8x52x70mm_e0eda9a4-c6bb-4472-a818-0e776b186cff.webp?v=1777160413"},{"product_id":"abb-1sfn034403r1000-vm140-190-mechanical-interlock","title":"ABB 1SFN034403R1000 VM140\/190 Mechanical Interlock Unit Mechanic Interlock for Switch","description":"\u003cp\u003eThe ABB VM140\/190 Mechanical Interlock Unit (SKU: 1SFN034403R1000) is a certified interlock accessory designed to prevent simultaneous operation of two switches, ensuring safe and reliable switching sequences in industrial control panels and automation systems. Compact and robust, the VM140\/190 is engineered to meet demanding industrial standards and integrates seamlessly into ABB switch assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM140\/190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFN034403R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM140\/190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical Interlock Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 × 41.8 × 84.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500494820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL certification confirming compliance with applicable Canadian safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances (EC No 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMechanical interlocking between two adjacent switches to prevent simultaneous closure\u003c\/li\u003e\n\u003cli\u003eIndustrial motor control centres (MCCs) requiring operational safety interlocks\u003c\/li\u003e\n\u003cli\u003eControl panel assemblies in manufacturing, process automation, and building management systems\u003c\/li\u003e\n\u003cli\u003eChangeover and transfer switch applications where only one circuit may be energised at a time\u003c\/li\u003e\n\u003cli\u003eSafety-critical switching sequences in industrial automation and machine control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229145927963,"sku":"1SFN034403R1000","price":19.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfn034403r1000-vm140-190-interlock-for-switch_13aa72b1-6816-4b5d-a09e-6432b4ccf6a8.webp?v=1777160403"},{"product_id":"abb-1sbn083406r1000-bea65-4-connecting-link-motor-starter","title":"ABB 1SBN083406R1000 BEA65-4 Connecting Link with Manual Motor Starter 3-Pole 35mm DIN Rail Accessory","description":"\u003cp\u003eThe ABB BEA65-4 (SKU: 1SBN083406R1000) is a 3-pole connecting link accessory designed to interface with ABB manual motor starters, enabling reliable and space-saving busbar connections on 35 mm DIN rail installations. Part of the BEA65 series, this compact component measures 55 × 64 × 60 mm and weighs just 71 g, making it ideal for dense control panel assemblies in industrial automation and motor protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA65-4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN083406R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting Link with Manual Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mm × 64 mm × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.071 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523131156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage motor controllers and starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.60947-1-13:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60947-1:\u003c\/strong\u003e European standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60947-4:\u003c\/strong\u003e European standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting ABB manual motor starters in multi-motor control panel configurations\u003c\/li\u003e\n  \u003cli\u003eDIN rail-mounted busbar linking in industrial automation cabinets\u003c\/li\u003e\n  \u003cli\u003eMotor protection and control assemblies in manufacturing and process industries\u003c\/li\u003e\n  \u003cli\u003eOEM machine builders requiring compact, certified motor starter accessories\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229146026267,"sku":"1SBN083406R1000","price":28.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn083406r1000-bea65-4-din-rail-accessory_ea8fb0eb-4e3a-414f-89b3-71f1a85fcb59.webp?v=1777157121"},{"product_id":"abb-1sbn082306t2000-bea38-4-connecting-link","title":"ABB 1SBN082306T2000 BEA38-4 Connecting Link with Manual Motor Starter 690V AC Accessory","description":"\u003cp\u003eThe ABB BEA38-4 (SKU: 1SBN082306T2000) is a connecting link accessory designed for use with manual motor starters, rated up to 690 V AC. Part of ABB's BEA series of low-voltage switch technology accessories, the BEA38-4 provides a reliable mechanical and electrical interface between motor starter components in control panel assemblies, supporting efficient installation and system integrity.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA38-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN082306T2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBEA38-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting Link with Manual Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 48 x 42.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL certification for low-voltage switchgear and controlgear — motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian Standards Association certification for low-voltage motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e CSA general electrical safety standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the UK market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229146091803,"sku":"1SBN082306T2000","price":8.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn082306t2000-bea38-4-690v-ac-accessory_5a52041b-5b6d-496d-9cc3-1bef34b3a569.webp?v=1777157117"},{"product_id":"abb-1sfn035203r1000-vm205-265-mechanical-interlock","title":"ABB 1SFN035203R1000 VM205\/265 Mechanical Interlock Unit Mechanic Interlock for Switch","description":"\u003cp\u003eThe ABB VM205\/265 Mechanical Interlock Unit (SKU: 1SFN035203R1000) is a dedicated mechanic interlock for switch assemblies, designed to prevent simultaneous operation of two switching devices in industrial control panels and automation systems. This compact accessory ensures safe, reliable interlocking in compliance with international standards, making it an essential component for engineers specifying motor control and switchgear installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM205\/265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFN035203R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM205\/265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical Interlock Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 x 42 x 70.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500494813\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO. 60947-5-1-14:\u003c\/strong\u003e Certified to Canadian Standards Association low-voltage switchgear and controlgear standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Underwriters Laboratories certification for the Canadian market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor reversing starter circuits requiring prevention of simultaneous forward\/reverse contactor energisation\u003c\/li\u003e\n\u003cli\u003eStar-delta starter assemblies in industrial motor control centres\u003c\/li\u003e\n\u003cli\u003eControl panel interlocking where two switching devices must never operate concurrently\u003c\/li\u003e\n\u003cli\u003eAutomation and process control switchgear in manufacturing, HVAC, and utilities\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229146517787,"sku":"1SFN035203R1000","price":19.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfn035203r1000-vm205-265-interlock-for-switch_52ed9297-ba84-4614-a51e-7022f74feab3.webp?v=1777160409"},{"product_id":"abb-1saz401110r0001-db200-single-mounting-kit","title":"ABB 1SAZ401110R0001 DB200 Single Mounting Kit Accessories\/Spare Parts for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB DB200 Single Mounting Kit (SKU: 1SAZ401110R0001) is a precision-engineered accessory for low-voltage switch technology, designed to provide secure and reliable single mounting of compatible ABB DB200 series components in industrial control panels and electrical enclosures. Rated for 690 V AC and configured for 3-pole applications, this mounting kit ensures compliant, efficient installation for demanding industrial automation environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAZ401110R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\/Spare Parts for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB200 Single Mounting Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 43 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.225 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614237768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 14:\u003c\/strong\u003e Canadian Standards Association certification for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4-1:\u003c\/strong\u003e Standard for electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear and controlgear — contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricting use of specific hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU health, safety and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB DB200 Single Mounting Kit is suited for use in a wide range of industrial automation and electrical distribution applications. Typical use cases include mounting of DB200 series devices within motor control centers (MCCs), control panels, and switchgear assemblies operating at up to 690 V AC. Its compact form factor (105 x 43 x 40 mm) and light weight (0.225 kg) make it ideal for space-constrained installations in manufacturing, process control, and building automation environments. Procurement engineers and panel builders specify this accessory alongside ABB DB200 series switch technology to ensure manufacturer-approved, standards-compliant assembly.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229158641947,"sku":"1SAZ401110R0001","price":19.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1saz401110r0001-db200-low-voltage-switch-technology_1e532556-8d3b-43a7-bb25-1ca41d6697c1.webp?v=1777156355"},{"product_id":"abb-1sca101655r1001-oxs6x130-switch-operating-shaft","title":"ABB 1SCA101655R1001 OXS6X130 6×6×130mm Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXS6X130 (SKU: 1SCA101655R1001) is a genuine ABB switch operating shaft designed for use with ABB's OXS series switching and disconnector mechanisms. Measuring 6×6×130 mm and weighing just 0.03 kg, the OXS6X130 shaft provides reliable mechanical actuation for industrial switchgear and control panel applications. This precision-engineered component ensures consistent, repeatable operation in demanding automation and power distribution environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXS6X130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA101655R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 × 6 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019365770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) — ensuring safe handling of chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with the updated RoHS2 directive and its amendment expanding the list of restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive — supports responsible end-of-life disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166735643,"sku":"1SCA101655R1001","price":13.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca101655r1001-oxs6x130-switch-operating-shaft_27ff5fe2-bb59-4db0-a238-539e32aaa083.webp?v=1777157529"},{"product_id":"abb-1sca108043r1001-oxs6x105-switch-operating-shaft","title":"ABB 1SCA108043R1001 OXS6X105 6x6x105mm Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXS6X105 (SKU: 1SCA108043R1001) is a genuine ABB switch operating shaft designed for precise mechanical actuation in industrial switching applications. Part of the ABB OXS series, this shaft measures 6×6×105mm and weighs just 0.02 kg, making it a compact yet reliable mechanical interface component for control panels and enclosed switching equipment.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXS6X105\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA108043R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 × 6 × 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019424118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance registration, evaluation, and authorisation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMechanical actuation interface for ABB OXS series enclosed switches and disconnectors\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies requiring extended or offset shaft drive mechanisms\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and motor control centre (MCC) builds\u003c\/li\u003e\n  \u003cli\u003eReplacement or spare shaft for maintenance of existing ABB OXS switch installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167030555,"sku":"1SCA108043R1001","price":13.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca108043r1001-oxs6x105-switch-operating-shaft_9c90073f-d7cc-4662-97a4-4af9e831539b.webp?v=1777157684"},{"product_id":"abb-1sca151422r1001-otm63f2c21d230c-2p-switch-disconnector","title":"ABB 1SCA151422R1001 OTM63F2C21D230C 2P 63A 230V AC Motorized Compact ATS Switch Disconnector","description":"\u003cp\u003eThe ABB OTM63F2C21D230C (SKU 1SCA151422R1001) is a 2-pole motorized Compact ATS switch disconnector from the ABB OTM series, rated at 63A with a 230V AC coil for automatic transfer switching applications. Designed for base mounting or DIN-rail installation, the OTM63F2C21D230C delivers reliable source changeover in a compact footprint suitable for control panels and distribution boards. This IEC60947-compliant device is engineered for industrial and commercial power reliability applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOTM63F2C21D230C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA151422R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOTM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact ATS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounting or DIN-rail Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019818276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, confirming the product is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation concerning the registration, evaluation, authorisation and restriction of chemicals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Designed and tested in accordance with IEC 60947, the international standard for low-voltage switchgear and controlgear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229230403867,"sku":"1SCA151422R1001","price":756.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca151422r1001-otm63f2c21d230c-abb-1sca151422r1001-otm63f2c21d230c_0553b0fe-98c1-4610-b964-77b717d86374.webp?v=1777393900"},{"product_id":"abb-1sca153457r1001-oxb250e3s2qt-4p-ats","title":"ABB 1SCA153457R1001 OXB250E3S2QT TruONE 4P 200-480VAC Open Style Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB250E3S2QT automatic transfer switch (SKU 1SCA153457R1001) is a 4-pole, open-style ATS from the TruONE series, rated for 200–480 VAC and engineered for seamless source switching in critical power infrastructure. Designed to meet the demands of industrial and commercial applications, the OXB250E3S2QT ensures reliable changeover between primary and backup power supplies, minimising downtime in control panels and distribution systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB250E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153457R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019844831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — automatic transfer switching equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of networked equipment and measures to improve the resource efficiency of networked equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted substances per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e CE marked in accordance with applicable EU directives for market access in the European Economic Area\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCritical power backup switching in data centres, hospitals, and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eGenerator-to-mains changeover in commercial buildings and infrastructure projects\u003c\/li\u003e\n  \u003cli\u003eMain distribution boards and MCC panels requiring automatic source transfer\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems where uninterrupted power is essential\u003c\/li\u003e\n  \u003cli\u003eUtility and renewable energy installations requiring dual-source management\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234270491,"sku":"1SCA153457R1001","price":1935.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153457r1001-oxb250e3s2qt-automatic-transfer-switch_497dd88d-0b01-40ff-b516-91e40cdb4ab3.webp?v=1777157778"},{"product_id":"abb-1sca153623r1001-oxb1600e3s2qt-1600a-ats","title":"ABB 1SCA153623R1001 OXB1600E3S2QT 1600A 3-Pole 200-480VAC Open Style TruONE Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB1600E3S2QT (SKU: 1SCA153623R1001) is a 1600A, 3-pole automatic transfer switch from the ABB TruONE series, designed for reliable source changeover in critical power applications. Rated for 200–480 VAC, this open-style ATS ensures seamless transfer between primary and backup power sources, safeguarding industrial installations, data centres, and commercial facilities against supply interruptions. The OXB1600E3S2QT delivers robust performance in demanding environments and meets the highest international electrical standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB1600E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153623R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019846491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — transfer switching equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on the registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on the restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for the CE marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Directive 2012\/19\/EU on waste electrical and electronic equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power backup and source changeover in data centres and server rooms\u003c\/li\u003e\n\u003cli\u003eEmergency power supply systems in hospitals, healthcare facilities, and life-safety installations\u003c\/li\u003e\n\u003cli\u003eIndustrial automation panels requiring uninterrupted power continuity\u003c\/li\u003e  \u003cli\u003eCommercial buildings with standby generator integration\u003c\/li\u003e\n\u003cli\u003eInfrastructure projects including utilities, water treatment, and transportation hubs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234663707,"sku":"1SCA153623R1001","price":5866.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153623r1001-oxb1600e3s2qt-automatic-transfer-switch_2cd56cc5-c02c-4087-a210-d1ee40ea7ae9.webp?v=1777157785"},{"product_id":"abb-1sca150935r1001-oxb800e3s2qt-800a-3p-ats","title":"ABB 1SCA150935R1001 OXB800E3S2QT TruONE 800A 3-Pole 200-480VAC Open Style Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB800E3S2QT automatic transfer switch (SKU: 1SCA150935R1001) is a 800A, 3-pole open-style ATS from the TruONE series, rated for 200–480 VAC systems. Designed for critical power continuity applications, this unit ensures seamless switchover between primary and backup power sources in industrial and commercial installations. Weighing 22.23 kg, the OXB800E3S2QT delivers robust, reliable transfer switching performance in compliance with IEC 60947-6-1 standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB800E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA150935R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019811710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — automatic transfer switching equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e IEC standard for low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability of electrical and electronic products to be repaired, reused, or recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power backup switching in data centres and server rooms\u003c\/li\u003e\n\u003cli\u003eAutomatic source changeover in hospitals and healthcare facilities\u003c\/li\u003e\u0026gt;\u003cli\u003eGenerator-to-mains transfer in industrial plants and manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eCommercial building standby power systems\u003c\/li\u003e\n\u003cli\u003eEmergency power supply (EPS) and uninterruptible power system (UPS) integration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat voltage range does the OXB800E3S2QT support?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe ABB OXB800E3S2QT is rated for 200–480 VAC, making it compatible with a wide range of three-phase industrial supply voltages.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow many poles does this automatic transfer switch have?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThis unit is a 3-pole ATS, suitable for three-phase power distribution systems.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the mounting style of the 1SCA150935R1001?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe OXB800E3S2QT uses an open-style mounting configuration, suitable for integration into enclosures or switchboard assemblies.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this product CE certified?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes, the OXB800E3S2QT carries CE marking and complies with IEC 60947-6-1, RoHS, and REACH requirements.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234991387,"sku":"1SCA150935R1001","price":3872.38,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca150935r1001-oxb800e3s2qt-automatic-transfer-switch_dd87f782-4ab1-4d27-96c3-aae6144a95e2.webp?v=1777157760"},{"product_id":"abb-1sca153430r1001-oxb200e3s3qt-4p-automatic-transfer-switch","title":"ABB 1SCA153430R1001 OXB200E3S3QT 4P 200-480VAC Open Style TruONE Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB200E3S3QT (SKU: 1SCA153430R1001) is a 4-pole open-style automatic transfer switch from the ABB TruONE series, rated for 200–480 VAC operation. Designed for reliable power source changeover in critical industrial and commercial applications, this ATS ensures seamless transition between primary and backup supplies, protecting connected loads from supply interruptions. Weighing 16.27 kg, the OXB200E3S3QT is built for panel integration in demanding control environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB200E3S3QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153430R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019844565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear – transfer switching equipment for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear – multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked standby-capable products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European health, safety, and environmental protection standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive for responsible disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power changeover in data centres, hospitals, and industrial facilities\u003c\/li\u003e\n\u003cli\u003eAutomatic switchover between mains supply and generator or UPS backup\u003c\/li\u003e\n\u003cli\u003eIntegration into MCC panels and centralised power distribution boards\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems requiring uninterrupted power continuity\u003c\/li\u003e\n\u003cli\u003eCommercial buildings with standby generator infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229240267035,"sku":"1SCA153430R1001","price":2477.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153430r1001-oxb200e3s3qt-automatic-transfer-switch_d06c3a44-f0d0-4629-9ba0-19beb26fe8bc.webp?v=1777157767"},{"product_id":"abb-1sca150190r1001-oxes1600g1l-4-terminal-shroud","title":"ABB 1SCA150190R1001 OXES1600G1L\/4 Terminal Shroud Accessory for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB OXES1600G1L\/4 (SKU: 1SCA150190R1001) is a terminal shroud accessory and spare part designed for ABB low-voltage switch technology applications. Catalogued as OXES1600G1L\/4, this precision-engineered component measures 115 x 165 x 167 mm and weighs 0.585 kg, offering a robust and reliable solution for control panel builders and maintenance engineers requiring genuine ABB replacement or supplementary parts.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXES1600G1L\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA150190R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019801292\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\/Spare Parts for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Shroud\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 x 165 x 167 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.585 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006, confirming safe chemical substance management throughout the supply chain.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with the RoHS recast directive and its amendment, meeting the most current European hazardous substance restrictions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life disposal and recycling obligations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eReplacement or supplementary terminal shroud for ABB low-voltage switching equipment\u003c\/li\u003e\n  \u003cli\u003eControl panel assembly and retrofit projects requiring genuine ABB spare parts\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and power distribution board maintenance\u003c\/li\u003e\n  \u003cli\u003eOEM and system integrators sourcing certified ABB accessories for compliance-sensitive installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229248557339,"sku":"1SCA150190R1001","price":45.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca150190r1001-oxes1600g1l-4-abb-1sca150190r1001-oxes1600g1l-4_653a5056-4aff-41f0-9ab7-df937b00c7b0.webp?v=1777393908"},{"product_id":"abb-1sca150202r1001-oxeb1600-6-phase-barrier","title":"ABB 1SCA150202R1001 OXEB1600\/6 Phase Barrier Accessory for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB OXEB1600\/6 (SKU: 1SCA150202R1001) is a phase barrier accessory designed for ABB low-voltage switch technology applications. Catalog number OXEB1600\/6 is the customer-facing reference found on datasheets and bills of materials. Weighing 0.713 kg and measuring 14 × 267 × 182 mm, this phase barrier provides reliable phase separation within switchgear and distribution assemblies, helping maintain electrical isolation and safe operation in industrial control panels and power distribution systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXEB1600\/6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA150202R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019801599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Barrier — Accessory for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 × 267 × 182 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.713 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, confirming the product is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), ensuring safe chemical substance management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life recycling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePhase separation and isolation within low-voltage switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eDistribution boards and motor control centres requiring physical phase barriers\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels where creepage and clearance distances must be maintained\u003c\/li\u003e\n\u003cli\u003eReplacement or spare part for ABB OXEB1600 series switchgear installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229248622875,"sku":"1SCA150202R1001","price":51.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca150202r1001-oxeb1600-6-abb-1sca150202r1001-oxeb1600-6_4a4f5679-08a8-4f89-9b88-549d36fe9ef3.webp?v=1777393912"},{"product_id":"abb-1sca022865r9510-ohb200j12p-pistol-handle","title":"ABB 1SCA022865R9510 OHB200J12P Pistol Handle 400x45x66mm 0.495kg","description":"\u003cp\u003eThe ABB OHB200J12P (SKU: 1SCA022865R9510) is a pistol handle designed for industrial electrical applications, providing reliable manual operation and control in switchgear and control panel assemblies. Compact and robust at 400 x 45 x 66 mm and weighing just 0.495 kg, the OHB200J12P delivers ergonomic, precise actuation suited to demanding automation and industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOHB200J12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022865R9510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019362113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePistol Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 45 x 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.495 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation governing chemicals and their safe use in industrial products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with the EU RoHS recast directive and its updated substance restrictions under Amendment 2015\/863.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eManual operation and actuation in industrial switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eControl panel integration for electrical automation systems\u003c\/li\u003e\n\u003cli\u003eErgonomic operator interface for switch disconnectors and enclosed switches\u003c\/li\u003e\n\u003cli\u003eIndustrial automation environments requiring reliable mechanical actuation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250294043,"sku":"1SCA022865R9510","price":50.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022865r9510-ohb200j12p-handle-400x45x66mm-0-495kg_06311658-f437-40de-9a7f-609138a15930.webp?v=1777157505"},{"product_id":"abb-1sca022056r6030-oxp6x430-switch-operating-shaft","title":"ABB 1SCA022056R6030 OXP6X430 6x6x430mm 0.11kg Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXP6X430 (SKU: 1SCA022056R6030) is a switch operating shaft designed for use with ABB enclosed switches and switch disconnectors. Measuring 6×6×430 mm and weighing just 0.11 kg, this precision-machined shaft transmits rotational force from an external operating mechanism to the internal switch contacts, enabling safe and reliable operation of enclosed switching equipment in industrial control panels and distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP6X430\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022056R6030\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 × 6 × 430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019141473\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals) ensuring safe chemical substance management\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive — supports responsible end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting external rotary handles or padlockable operators to enclosed switch disconnectors\u003c\/li\u003e\n  \u003cli\u003eThrough-door operation of ABB enclosed switches in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eMachine tool and automation panel wiring where safe isolation is required\u003c\/li\u003e\n  \u003cli\u003eBuilding services distribution boards requiring door-interlock switching mechanisms\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250359579,"sku":"1SCA022056R6030","price":6.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022056r6030-oxp6x430-switch-operating-shaft_10fc0ce0-aa25-4835-aa6b-5d8c1a5f97e9.webp?v=1777157130"},{"product_id":"abb-1sca022865r9430-ohb150j12p-handle","title":"ABB 1SCA022865R9430 OHB150J12P Handle 300x66x45mm 0.435kg","description":"\u003cp\u003eThe ABB OHB150J12P (SKU: 1SCA022865R9430) is a genuine ABB handle designed for use with ABB switching and disconnecting devices, providing reliable manual operation and secure mechanical actuation. Compact at 300 x 66 x 45 mm and weighing just 0.435 kg, the OHB150J12P is engineered to meet the demanding requirements of industrial control panels and switchgear assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOHB150J12P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022865R9430\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHandle\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019335223\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 x 66 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.435 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — free from restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety and substance registration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe ABB OHB150J12P handle is suited for industrial switchgear enclosures, control panels, and distribution boards where reliable manual operation of disconnect switches or similar ABB devices is required. Its robust construction and compact form factor make it ideal for automation and electrical control applications across manufacturing, infrastructure, and building services sectors.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250425115,"sku":"1SCA022865R9430","price":50.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022865r9430-ohb150j12p-abb-1sca022865r9430-ohb150j12p_82c0d013-4759-4bcd-bfe7-024d954b40a7.webp?v=1777393915"},{"product_id":"abb-1sca022381r2110-ohb145j12-pistol-handle","title":"ABB 1SCA022381R2110 OHB145J12 Pistol Handle 145mm Base \u0026 DIN-Rail Mount IP65","description":"\u003cp\u003eThe ABB OHB145J12 pistol handle (SKU 1SCA022381R2110) is a 145 mm industrial pistol-grip operating handle designed for base and DIN-rail mounted switch disconnectors and enclosed switches. Rated IP65 and NEMA 12, the OHB145J12 delivers reliable manual actuation in demanding industrial environments where dust and water ingress protection is critical. Weighing just 0.175 kg, it integrates seamlessly into control panels and machine enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOHB145J12\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022381R2110\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019124353\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePistol Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase and DIN-rail mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHandle Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 1, NEMA 3R, NEMA 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP65:\u003c\/strong\u003e Protected against dust ingress and low-pressure water jets from any direction\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEMA 1:\u003c\/strong\u003e General-purpose indoor enclosure protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEMA 3R:\u003c\/strong\u003e Rainproof, sleet-proof and ice-resistant for outdoor use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEMA 12:\u003c\/strong\u003e Industrial use — protection against dust, falling dirt and dripping non-corrosive liquids\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets applicable EU directives for the European market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManual actuation of base-mounted and DIN-rail-mounted switch disconnectors in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eMachine tool enclosures requiring ergonomic pistol-grip handle operation\u003c\/li\u003e\n  \u003cli\u003ePanel boards and motor control centres where IP65 ingress protection is required\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation cabinets in manufacturing, process and utility environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250490651,"sku":"1SCA022381R2110","price":23.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022381r2110-ohb145j12-din-rail-mount-ip65_74de8474-b8e3-4c02-8bbe-f74b4864a54e.webp?v=1777157161"},{"product_id":"abb-1sca022042r6110-oxp12x535-switch-operating-shaft","title":"ABB 1SCA022042R6110 OXP12X535 12x12x535mm 0.59kg Switch Operating Shaft","description":"\u003cp\u003eThe ABB OXP12X535 switch operating shaft (SKU: 1SCA022042R6110) is a precision-engineered OXP series component designed for actuating and transmitting rotational motion in industrial switch and disconnector assemblies. Measuring 12 x 12 x 535 mm and weighing 0.59 kg, the OXP12X535 provides reliable mechanical coupling between external operating handles and internal switch mechanisms in control panels and switchgear installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP12X535\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022042R6110\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Operating Shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 x 12 x 535 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019141404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), confirming safe chemical composition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250556187,"sku":"1SCA022042R6110","price":18.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022042r6110-oxp12x535-switch-operating-shaft_13e07fad-67ee-4d42-9805-d607791a5d23.webp?v=1777157125"},{"product_id":"abb-1sca105004r1001-ot100f3-3p-switch-disconnector","title":"ABB 1SCA105004R1001 OT100F3 3-Pole 100A Base\/DIN-Rail Mount Switch Disconnector","description":"\u003cp\u003eThe ABB OT100F3 (SKU: 1SCA105004R1001) is a 3-pole low-voltage switch disconnector from ABB's OT Series, designed for safe isolation and switching of electrical circuits in industrial control panels and distribution boards. Combining base-mount and DIN-rail mounting flexibility with compact dimensions of 70 × 100 × 74 mm and a lightweight 0.36 kg build, the OT100F3 delivers reliable disconnection in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT100F3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA105004R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Disconnector (Low Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounted, DIN-rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 100 mm × 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019391359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Meets European RoHS legislative requirements including latest amendments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ UL 98 \/ CSA C22.2 NO.4:\u003c\/strong\u003e Certified to international standards for switches for equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 NO.4:\u003c\/strong\u003e Canadian Standards Association — switches for use in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Suitable for use in potentially explosive atmospheres\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European CE marking requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Certified by Underwriters Laboratories for US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Certified by Verband der Elektrotechnik (German electrical engineering association)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eSafe isolation of electrical circuits in industrial machinery and control panels\u003c\/li\u003e\n  \u003cli\u003eMain or branch circuit disconnection in distribution boards and motor control centres\u003c\/li\u003e\n  \u003cli\u003ePanel-building applications requiring both base-mount and DIN-rail mounting flexibility\u003c\/li\u003e\n  \u003cli\u003eUse in potentially explosive atmospheres (ATEX-rated environments)\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems requiring certified, multi-standard compliant switching\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229262549275,"sku":"1SCA105004R1001","price":44.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca105004r1001-ot100f3-mount-switch-disconnector_13f10820-870a-4a25-8c77-e3fdd86954a2.webp?v=1777157592"},{"product_id":"abb-1sca105798r1001-ot80f3-80a-3p-switch-disconnector","title":"ABB 1SCA105798R1001 OT80F3 3-Pole 80A Base\/DIN-Rail Mount Switch Disconnector Low Voltage","description":"\u003cp\u003eThe ABB OT80F3 switch disconnector (SKU 1SCA105798R1001) is a 3-pole, 80 A low-voltage isolating switch designed for safe circuit isolation in industrial control panels and power distribution systems. Part of ABB's trusted OT series, the OT80F3 supports both base mounting and DIN-rail mounting, offering flexible installation in compact enclosures. Compliant with IEC 60947-3, UL 508, and CSA C22.2 No.14, it is engineered for demanding industrial automation and electrical infrastructure applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT80F3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA105798R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounted, DIN-rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 91.5 mm × 72.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019397016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors, and switch-disconnectors in low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment (North America)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined Canadian and US product safety listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking for the EU market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e German electrotechnical institute certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSafe isolation and disconnection of industrial machinery and control panels\u003c\/li\u003e\n\u003cli\u003ePower distribution boards and motor control centres (MCCs)\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC electrical distribution\u003c\/li\u003e\n\u003cli\u003eRenewable energy and generator protection switchboards\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail installations where space is critical\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229262844187,"sku":"1SCA105798R1001","price":34.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca105798r1001-ot80f3-disconnector-low-voltage_ed9ad1e1-54e0-4b43-859d-0ba4c8cdd23c.webp?v=1777157674"},{"product_id":"abb-1sca104902r1001-ot40f3-3p-switch-disconnector","title":"ABB 1SCA104902R1001 OT40F3 3-Pole 40A Base\/DIN-Rail Mount Switch Disconnector Low Voltage","description":"\u003cp\u003eThe ABB OT40F3 (SKU: 1SCA104902R1001) is a 3-pole low voltage switch disconnector from ABB's OT series, designed for safe isolation and switching of electrical circuits in industrial control panels and distribution boards. Compact at 35 mm × 68 mm × 56 mm and weighing just 0.09 kg, the OT40F3 supports both base mounting and DIN-rail mounting, offering installation flexibility across a wide range of applications. Certified to IEC 60947-3, UL508, and ATEX standards, it is a trusted solution for engineers and procurement professionals worldwide.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT40F3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA104902R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Disconnector (Low Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounted, DIN-rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 68 mm × 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019390451\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e EU Directive 2011\/65\/EU — restriction of hazardous substances in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e RoHS 2 amendment updating restricted substance thresholds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors and fuse-combination units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-10:\u003c\/strong\u003e International standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment (North America)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL and CSA certification for US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU directive 2014\/34\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrical engineering standards compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eSafe electrical isolation in industrial control panels and machine switchboards\u003c\/li\u003e\n  \u003cli\u003eCircuit disconnection in distribution boards and motor control centers\u003c\/li\u003e\n  \u003cli\u003eUse in hazardous areas requiring ATEX-rated switching components\u003c\/li\u003e\n  \u003cli\u003eNorth American installations requiring UL508 and CSA C22.2 No.14 compliance\u003c\/li\u003e\n  \u003cli\u003eOEM machinery and automation equipment requiring compact, DIN-rail-compatible disconnectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229263630619,"sku":"1SCA104902R1001","price":19.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca104902r1001-ot40f3-disconnector-low-voltage_bfa17c5a-ee9f-4364-be37-35039b4441da.webp?v=1777157565"},{"product_id":"abb-1sca104811r1001-ot16f3-3p-switch-disconnector","title":"ABB 1SCA104811R1001 OT16F3 3-Pole 16A Base\/DIN-Rail Mount Switch Disconnector Low Voltage","description":"\u003cp\u003eThe ABB OT16F3 switch disconnector (SKU 1SCA104811R1001) is a 3-pole, low-voltage switch disconnector from ABB's OT series, designed for safe isolation and switching in industrial control panels and distribution boards. Compliant with IEC 60947-3, UL 508, and CSA C22.2 No.14, the OT16F3 offers versatile mounting options — both base-mounted and DIN-rail mountable — in a compact 35 × 68 × 56 mm footprint weighing just 0.09 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT16F3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA104811R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounted, DIN-rail mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 68 mm × 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019389554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking for electrical safety and EMC compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by UL for both US (UL 508) and Canadian (CSA C22.2 No.14) markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e German Association for Electrical, Electronic \u0026amp; Information Technologies certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (North American market)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certification for use in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSafe isolation of electrical circuits in industrial control panels\u003c\/li\u003e\n\u003cli\u003eMain or branch switch in distribution boards and motor control centres\u003c\/li\u003e\n\u003cli\u003eOn\/off switching and load isolation in automation systems\u003c\/li\u003e\n\u003cli\u003eApplications requiring ATEX-rated safe disconnection in hazardous areas\u003c\/li\u003e\n\u003cli\u003eCompact installations requiring DIN-rail or base mounting flexibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229263892763,"sku":"1SCA104811R1001","price":14.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca104811r1001-ot16f3-disconnector-low-voltage_bc16c630-aca6-4d3d-ba5a-8321d5665aea.webp?v=1777157556"},{"product_id":"abb-1sca022710r0100-ot250e03p-250a-3p-switch-disconnector","title":"ABB 1SCA022710R0100 OT250E03P 3-Pole Base Mount 250A Switch Disconnector Low Voltage","description":"\u003cp\u003eThe ABB OT250E03P (SKU: 1SCA022710R0100) is a 3-pole, base-mounted low-voltage switch disconnector from ABB's OT series, designed for safe isolation and switching of electrical circuits in industrial control panels and power distribution systems. Rated at 250A and built to IEC 60947-3 standards, this switch disconnector provides reliable galvanic isolation for downstream equipment, making it a trusted choice for engineers and procurement professionals in industrial automation and energy management applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT250E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022710R0100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Disconnector (Low Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145.5 mm × 150 mm × 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019225944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — switches, disconnectors, and switch-disconnectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-115:\u003c\/strong\u003e Supplementary IEC standard applicable to this switch-disconnector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60664:\u003c\/strong\u003e European harmonized version of insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified to German VDE electrical safety standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain isolation and switching in industrial control panels and motor control centers (MCCs)\u003c\/li\u003e\n  \u003cli\u003eSafe disconnection of machinery and equipment for maintenance and servicing\u003c\/li\u003e\n  \u003cli\u003ePower distribution boards in manufacturing, utilities, and process industries\u003c\/li\u003e\n  \u003cli\u003eATEX-rated installations in potentially explosive or hazardous environments\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and energy management systems requiring reliable galvanic isolation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229264187675,"sku":"1SCA022710R0100","price":132.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022710r0100-ot250e03p-disconnector-low-voltage_0e8d2350-2a93-4168-8ee6-ee483919a234.webp?v=1777157314"},{"product_id":"abb-1sca022718r9410-ot800e03p-800a-3p-switch-disconnector","title":"ABB 1SCA022718R9410 OT800E03P 3-Pole 800A Base Mounted Switch-Disconnector","description":"\u003cp\u003eThe ABB OT800E03P (SKU: 1SCA022718R9410) is a 3-pole, base-mounted switch-disconnector from ABB's OT series, engineered for reliable isolation and switching of electrical circuits in demanding industrial environments. Weighing 6.5 kg, the OT800E03P provides robust, safe disconnection for control panels, power distribution boards, and heavy-duty industrial installations. Its compact design and compliance with IEC 60947-3 make it the trusted choice for engineers and procurement professionals worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT800E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022718R9410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with applicable European Union directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and approved by VDE (Verband der Elektrotechnik)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and branch circuit isolation in industrial control panels\u003c\/li\u003e\n\u003cli\u003ePower distribution boards requiring reliable manual disconnection\u003c\/li\u003e\n\u003cli\u003eHeavy-duty motor and machinery isolation\u003c\/li\u003e\n\u003cli\u003eInstallations in potentially explosive atmospheres (ATEX-rated environments)\u003c\/li\u003e\n\u003cli\u003eEnergy management and maintenance isolation in automation systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229264449819,"sku":"1SCA022718R9410","price":409.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022718r9410-ot800e03p-base-mounted-switch-disconnector_e0623843-7720-4d6b-8149-74f42b63f5de.webp?v=1777157350"},{"product_id":"abb-1sca022718r8940-ot630e03p-630a-3p-switch-disconnector","title":"ABB 1SCA022718R8940 OT630E03P 3-Pole 630A Base Mounted Switch-Disconnector","description":"\u003cp\u003eThe ABB OT630E03P (SKU: 1SCA022718R8940) is a 3-pole, base-mounted switch-disconnector from the ABB OT Series, engineered for reliable isolation and switching of electrical circuits in industrial control panels and power distribution applications. Rated at 630A and weighing 6.8 kg, this heavy-duty switch-disconnector meets the rigorous demands of industrial automation environments. Compliant with IEC 60947-3 and a full suite of international standards, the OT630E03P delivers the safe disconnection performance required by engineers and plant operators worldwide.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT630E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022718R8940\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS2 compliance for electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Updated RoHS substance restrictions compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, and switch-disconnectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking for the EU market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Certified by the Association for Electrical, Electronic \u0026amp; Information Technologies (Germany)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain isolation switching in industrial control panels and motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003ePower distribution switchboards requiring reliable 3-pole disconnection\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems where safe maintenance isolation is critical\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty applications in manufacturing, process industries, and utilities\u003c\/li\u003e\n  \u003cli\u003eInstallations in potentially explosive atmospheres (ATEX-rated environments)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229264744731,"sku":"1SCA022718R8940","price":248.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022718r8940-ot630e03p-base-mounted-switch-disconnector_e288f9cf-e50e-48ef-b8a6-19a155cff385.webp?v=1777157345"},{"product_id":"abb-1sca022718r8510-ot315e03p-3p-switch-disconnector","title":"ABB 1SCA022718R8510 OT315E03P 3-Pole Base Mounted Switch-Disconnector 315A OT Series","description":"\u003cp\u003eThe ABB OT315E03P (SKU: 1SCA022718R8510) is a 3-pole base mounted switch-disconnector from ABB's OT series, designed for safe isolation and switching of electrical circuits in industrial control panels and distribution systems. Engineered to IEC 60947-3 standards, the OT315E03P delivers reliable load disconnection and overcurrent isolation for demanding industrial automation environments. With compact dimensions of 191 mm × 185 mm × 107 mm and a weight of 3.5 kg, it is well suited for panel builders and system integrators requiring robust, space-efficient disconnection solutions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT315E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022718R8510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e191 mm × 185 mm × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230436\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS recast directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2015\/863:\u003c\/strong\u003e Amendment to RoHS directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-130:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified to VDE (Verband der Elektrotechnik) German electrical engineering standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSafe isolation of electrical circuits in industrial control panels and machinery\u003c\/li\u003e\n\u003cli\u003eLoad disconnection in distribution boards and motor control centres\u003c\/li\u003e\n\u003cli\u003eOn\/off switching and maintenance isolation in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eApplications in potentially explosive atmospheres (ATEX-rated)\u003c\/li\u003e\n\u003cli\u003ePanel building and switchgear assembly requiring base-mounted 3-pole disconnectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229265596699,"sku":"1SCA022718R8510","price":173.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022718r8510-ot315e03p-315a-ot-series_abd89046-39b3-4edf-8e72-cd7e4d8c8537.webp?v=1777157334"},{"product_id":"abb-1sca022718r8780-ot400e03p-switch-disconnector","title":"ABB 1SCA022718R8780 OT400E03P 3-Pole 400A Base Mounted Switch-Disconnector","description":"\u003cp\u003eThe ABB OT400E03P (SKU: 1SCA022718R8780) is a heavy-duty 3-pole base-mounted switch-disconnector from ABB's OT series, engineered for reliable isolation and switching in industrial power distribution and control panel applications. Rated at 400A, this switch-disconnector meets the rigorous requirements of IEC 60947-3 and carries ATEX certification, making it suitable for use in demanding environments including potentially explosive atmospheres.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT400E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022718R8780\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e191 mm × 185 mm × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-130:\u003c\/strong\u003e Low-voltage switchgear and controlgear supplementary standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres per EU Directive 2014\/34\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — compliant with applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified by the German Association for Electrical, Electronic \u0026amp; Information Technologies\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant (2012\/19\/EU)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain supply isolation in industrial control panels and motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eSafe disconnection of machinery and equipment during maintenance operations\u003c\/li\u003e\n  \u003cli\u003ePower distribution switchboards in manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003eHazardous area installations where ATEX compliance is required\u003c\/li\u003e\n  \u003cli\u003eBuilding services, HVAC, and utility distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229265891611,"sku":"1SCA022718R8780","price":191.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022718r8780-ot400e03p-base-mounted-switch-disconnector_8f48aa52-47a1-4de0-bc56-da95c9f8e73a.webp?v=1777157339"},{"product_id":"abb-1sca022860r5930-ot1000e03p-switch-disconnector","title":"ABB 1SCA022860R5930 OT1000E03P 3-Pole 1000A Base Mount Switch-Disconnector","description":"\u003cp\u003eThe ABB OT1000E03P (SKU: 1SCA022860R5930) is a heavy-duty 3-pole base-mounted switch-disconnector designed for safe isolation and load switching in industrial power distribution systems. Rated for high-current applications and weighing 16.9 kg, the OT1000E03P meets the rigorous demands of industrial control panels, motor circuits, and main distribution boards. Built to IEC 60947-3 standards, this switch-disconnector delivers reliable performance in demanding environments including potentially explosive atmospheres (ATEX certified).\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT1000E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022860R5930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019309309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU RoHS amendment extending restricted substances list\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Certified by Verband der Elektrotechnik — German electrical engineering standards body\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain isolation and load switching in industrial power distribution boards\u003c\/li\u003e\n\u003cli\u003eMotor circuit disconnection and protection in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eSafe isolation of heavy machinery in process automation environments\u003c\/li\u003e\n\u003cli\u003eControl panel main supply isolation for MV\/LV switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eApplications in potentially explosive atmospheres (ATEX-rated environments)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229266153755,"sku":"1SCA022860R5930","price":657.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022860r5930-ot1000e03p-base-mount-switch-disconnector_f497bdae-27aa-4cee-95fd-bae6cfa6acbd.webp?v=1777157490"},{"product_id":"abb-1sca135139r1001-ot160g03p-3p-switch-disconnector","title":"ABB 1SCA135139R1001 OT160G03P 3-Pole Base Mounted 160A Switch Disconnector Low Voltage","description":"\u003cp\u003eThe ABB OT160G03P (SKU: 1SCA135139R1001) is a 3-pole, base-mounted switch disconnector(low voltage) from the OT160G series, designed for safe isolation and switching of electrical circuits in industrial control panels and distribution systems. Compliant with IEC 60947-3, UL98, and CSA C22.2 No.4, this compact disconnect switch measures 123 mm × 130 mm and weighs just 0.9 kg, making it suitable for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT160G03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA135139R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT160G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Disconnector (Low Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123 mm × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019638706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Restriction of hazardous substances in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Updated RoHS substance list compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ UL98 \/ CSA C22.2 No.4:\u003c\/strong\u003e International and North American standards for disconnectors and switch-disconnectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.4:\u003c\/strong\u003e Canadian standard for switches and disconnectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Suitable for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by UL for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified by the German Association for Electrical, Electronic \u0026amp; Information Technologies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSafe isolation of electrical circuits in industrial machinery and control panels\u003c\/li\u003e\n\u003cli\u003eMotor circuit disconnection in compliance with IEC 60947-3\u003c\/li\u003e\n\u003cli\u003eDistribution boards and switchgear assemblies requiring base-mounted disconnectors\u003c\/li\u003e\n\u003cli\u003eHazardous area installations (ATEX-rated environments)\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems requiring reliable on\/off switching and maintenance isolation\u003c\/li\u003e\n\u003cli\u003eOEM panel builders and system integrators requiring cULus and CE dual-certified devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229266579739,"sku":"1SCA135139R1001","price":80.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca135139r1001-ot160g03p-disconnector-low-voltage_f155d970-5158-443e-a41e-c429ebf3f9c0.webp?v=1777157748"},{"product_id":"abb-1sca022860r6230-ot1250e03p-3p-switch-disconnector","title":"ABB 1SCA022860R6230 OT1250E03P 3-Pole 1250A Base Mounted Switch-Disconnector","description":"\u003cp\u003eThe ABB OT1250E03P (SKU: 1SCA022860R6230) is a heavy-duty 3-pole base mounted switch-disconnector from ABB's OT series, rated at 1250A for reliable isolation and load switching in industrial power distribution systems. Designed to meet IEC 60947-3 requirements, this switch-disconnector delivers safe, dependable disconnection of electrical circuits in demanding industrial and commercial environments. Weighing 16.9 kg, the OT1250E03P is built for robust panel and switchgear installations where high-current isolation is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT1250E03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022860R6230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019309330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European adoption of IEC 60664-1 insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrical engineering certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances (EC 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance — supports responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and branch circuit isolation in industrial switchgear panels and motor control centres\u003c\/li\u003e\n\u003cli\u003eSafe disconnection and maintenance isolation of high-current electrical loads up to 1250A\u003c\/li\u003e\n\u003cli\u003ePower distribution boards in manufacturing plants, utilities, and infrastructure projects\u003c\/li\u003e\n\u003cli\u003eATEX-rated installations in hazardous areas such as oil \u0026amp; gas, chemical, and offshore environments\u003c\/li\u003e\n\u003cli\u003eBuilding services and commercial facility management distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229266940187,"sku":"1SCA022860R6230","price":712.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/OT1000_1250E03P_master.jpg?v=1782633628"}],"url":"https:\/\/stoklink.com\/collections\/switch-disconnectors-transfer-switches.oembed?page=6","provider":"Stoklink","version":"1.0","type":"link"}