{"title":"Siemens SENTRON 3VM MCCBs","description":"\u003cp\u003eSiemens SENTRON 3VM MCCBs are molded case circuit breakers for 16 A to 630 A distribution circuits. The range covers 3-pole and 4-pole breakers at 415 V, with more than 100 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e3VM1 breakers in several frame sizes.\u003c\/li\u003e\n\u003cli\u003eTM210, TM220 and similar thermal-magnetic trip units.\u003c\/li\u003e\n\u003cli\u003eBreaking capacities of 25 kA and 36 kA at 415 V in the listed parts.\u003c\/li\u003e\n\u003cli\u003eHigher ratings: \u003ca href=\"\/collections\/siemens-sentron-3va\"\u003eSiemens SENTRON 3VA MCCBs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFrame size and rated current must cover the load.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity at 415 V must exceed the fault level.\u003c\/li\u003e\n\u003cli\u003ePole count follows the neutral arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does LI mean in a 3VM title?\u003c\/h3\u003e\u003cp\u003eLI refers to the protection functions of the trip unit, long-time and instantaneous.\u003c\/p\u003e\u003ch3\u003eWhen should I pick 3VA over 3VM?\u003c\/h3\u003e\u003cp\u003eFor ratings above 630 A or where electronic trip units are required, choose 3VA.\u003c\/p\u003e\u003ch3\u003eDo you export 3VM breakers?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"siemens-3vm1010-3ed32-0aa0-3vm1-3p-100a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1010-3ED32-0AA0 3VM1 3P 100A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1010-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1010-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.941 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 25 kA breaking capacity, the 3VM1010-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713151259,"sku":"3VM1010-3ED32-0AA0","price":101.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1010-3ed32-0aa0.webp?v=1784360766"},{"product_id":"siemens-3vm1010-3ed42-0aa0-3vm1-4p-100a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1010-3ED42-0AA0 3VM1 4P 100A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1010-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1010-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.164 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 25 kA breaking capacity, the 3VM1010-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713184027,"sku":"3VM1010-3ED42-0AA0","price":127.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1010-3ed42-0aa0.webp?v=1784360772"},{"product_id":"siemens-3vm1010-4ed32-0aa0-3vm1-3p-100a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1010-4ED32-0AA0 3VM1 3P 100A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1010-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1010-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VM1010-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713216795,"sku":"3VM1010-4ED32-0AA0","price":131.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1010-4ed32-0aa0.webp?v=1784360779"},{"product_id":"siemens-3vm1010-4ed42-0aa0-3vm1-4p-100a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1010-4ED42-0AA0 3VM1 4P 100A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1010-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1010-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.164 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VM1010-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713249563,"sku":"3VM1010-4ED42-0AA0","price":131.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1010-4ed42-0aa0.webp?v=1784360785"},{"product_id":"siemens-3vm1020-3ed32-0aa0-3vm1-3p-20a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1020-3ED32-0AA0 3VM1 3P 20A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1020-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 20 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1020-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.944 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 25 kA breaking capacity, the 3VM1020-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713282331,"sku":"3VM1020-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1020-3ed32-0aa0.webp?v=1784360792"},{"product_id":"siemens-3vm1020-3ed42-0aa0-3vm1-4p-20a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1020-3ED42-0AA0 3VM1 4P 20A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1020-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 20 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1020-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 25 kA breaking capacity, the 3VM1020-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713315099,"sku":"3VM1020-3ED42-0AA0","price":147.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1020-3ed42-0aa0.webp?v=1784360802"},{"product_id":"siemens-3vm1020-4ed32-0aa0-3vm1-3p-20a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1020-4ED32-0AA0 3VM1 3P 20A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1020-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1020-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.941 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VM1020-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713347867,"sku":"3VM1020-4ED32-0AA0","price":123.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1020-4ed32-0aa0.webp?v=1784360809"},{"product_id":"siemens-3vm1020-4ed42-0aa0-3vm1-4p-20a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1020-4ED42-0AA0 3VM1 4P 20A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1020-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 20 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1020-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 20 A rated current and 36 kA breaking capacity, the 3VM1020-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713380635,"sku":"3VM1020-4ED42-0AA0","price":150.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1020-4ed42-0aa0.webp?v=1784360815"},{"product_id":"siemens-3vm1025-3ed32-0aa0-3vm1-3p-25a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1025-3ED32-0AA0 3VM1 3P 25A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1025-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 25 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1025-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.945 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 25 kA breaking capacity, the 3VM1025-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713446171,"sku":"3VM1025-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1025-3ed32-0aa0.webp?v=1784360822"},{"product_id":"siemens-3vm1025-3ed42-0aa0-3vm1-4p-25a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1025-3ED42-0AA0 3VM1 4P 25A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1025-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 25 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1025-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 25 kA breaking capacity, the 3VM1025-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713478939,"sku":"3VM1025-3ED42-0AA0","price":147.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1025-3ed42-0aa0.webp?v=1784360828"},{"product_id":"siemens-3vm1025-4ed32-0aa0-3vm1-3p-25a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1025-4ED32-0AA0 3VM1 3P 25A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1025-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1025-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.942 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VM1025-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713511707,"sku":"3VM1025-4ED32-0AA0","price":100.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1025-4ed32-0aa0.webp?v=1784360836"},{"product_id":"siemens-3vm1025-4ed42-0aa0-3vm1-4p-25a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1025-4ED42-0AA0 3VM1 4P 25A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1025-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 25 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1025-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 25 A rated current and 36 kA breaking capacity, the 3VM1025-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713544475,"sku":"3VM1025-4ED42-0AA0","price":150.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1025-4ed42-0aa0.webp?v=1784360842"},{"product_id":"siemens-3vm1032-3ed32-0aa0-3vm1-3p-32a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1032-3ED32-0AA0 3VM1 3P 32A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1032-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 32 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1032-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.917 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 32 A rated current and 25 kA breaking capacity, the 3VM1032-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713577243,"sku":"3VM1032-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1032-3ed32-0aa0.webp?v=1784360849"},{"product_id":"siemens-3vm1032-3ed42-0aa0-3vm1-4p-32a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1032-3ED42-0AA0 3VM1 4P 32A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1032-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 32 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1032-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 32 A rated current and 25 kA breaking capacity, the 3VM1032-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713610011,"sku":"3VM1032-3ED42-0AA0","price":120.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1032-3ed42-0aa0.webp?v=1784360855"},{"product_id":"siemens-3vm1032-4ed32-0aa0-3vm1-3p-32a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1032-4ED32-0AA0 3VM1 3P 32A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1032-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 32 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1032-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.945 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 32 A rated current and 36 kA breaking capacity, the 3VM1032-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713642779,"sku":"3VM1032-4ED32-0AA0","price":100.67,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1032-4ed32-0aa0.webp?v=1784360862"},{"product_id":"siemens-3vm1032-4ed42-0aa0-3vm1-4p-32a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1032-4ED42-0AA0 3VM1 4P 32A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1032-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 32 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1032-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.177 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 32 A rated current and 36 kA breaking capacity, the 3VM1032-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713675547,"sku":"3VM1032-4ED42-0AA0","price":150.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1032-4ed42-0aa0.webp?v=1784360868"},{"product_id":"siemens-3vm1040-3ed32-0aa0-3vm1-3p-40a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1040-3ED32-0AA0 3VM1 3P 40A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1040-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 40 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1040-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.855 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 40 A rated current and 25 kA breaking capacity, the 3VM1040-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713708315,"sku":"3VM1040-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1040-3ed32-0aa0.webp?v=1784360875"},{"product_id":"siemens-3vm1040-3ed42-0aa0-3vm1-4p-40a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1040-3ED42-0AA0 3VM1 4P 40A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1040-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 40 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1040-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.182 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 40 A rated current and 25 kA breaking capacity, the 3VM1040-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713806619,"sku":"3VM1040-3ED42-0AA0","price":120.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1040-3ed42-0aa0.webp?v=1784360882"},{"product_id":"siemens-3vm1040-4ed32-0aa0-3vm1-3p-40a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1040-4ED32-0AA0 3VM1 3P 40A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1040-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 40 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1040-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.953 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 40 A rated current and 36 kA breaking capacity, the 3VM1040-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713839387,"sku":"3VM1040-4ED32-0AA0","price":100.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1040-4ed32-0aa0.webp?v=1784360889"},{"product_id":"siemens-3vm1040-4ed42-0aa0-3vm1-4p-40a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1040-4ED42-0AA0 3VM1 4P 40A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1040-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 40 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1040-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.182 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 40 A rated current and 36 kA breaking capacity, the 3VM1040-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713872155,"sku":"3VM1040-4ED42-0AA0","price":122.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1040-4ed42-0aa0.webp?v=1784360899"},{"product_id":"siemens-3vm1050-3ed32-0aa0-3vm1-3p-50a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1050-3ED32-0AA0 3VM1 3P 50A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1050-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 50 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1050-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.934 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 50 A rated current and 25 kA breaking capacity, the 3VM1050-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619713970459,"sku":"3VM1050-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1050-3ed32-0aa0.webp?v=1784360906"},{"product_id":"siemens-3vm1050-3ed42-0aa0-3vm1-4p-50a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1050-3ED42-0AA0 3VM1 4P 50A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1050-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 50 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1050-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 50 A rated current and 25 kA breaking capacity, the 3VM1050-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714003227,"sku":"3VM1050-3ED42-0AA0","price":120.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1050-3ed42-0aa0.webp?v=1784360912"},{"product_id":"siemens-3vm1050-4ed32-0aa0-3vm1-3p-50a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1050-4ED32-0AA0 3VM1 3P 50A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1050-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 50 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1050-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.936 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 50 A rated current and 36 kA breaking capacity, the 3VM1050-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714035995,"sku":"3VM1050-4ED32-0AA0","price":100.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1050-4ed32-0aa0.webp?v=1784360919"},{"product_id":"siemens-3vm1050-4ed42-0aa0-3vm1-4p-50a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1050-4ED42-0AA0 3VM1 4P 50A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1050-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 50 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1050-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.161 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 50 A rated current and 36 kA breaking capacity, the 3VM1050-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714068763,"sku":"3VM1050-4ED42-0AA0","price":122.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1050-4ed42-0aa0.webp?v=1784360927"},{"product_id":"siemens-3vm1063-3ed32-0aa0-3vm1-3p-63a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1063-3ED32-0AA0 3VM1 3P 63A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1063-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 63 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1063-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.919 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 63 A rated current and 25 kA breaking capacity, the 3VM1063-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714101531,"sku":"3VM1063-3ED32-0AA0","price":89.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1063-3ed32-0aa0.webp?v=1784360934"},{"product_id":"siemens-3vm1063-3ed42-0aa0-3vm1-4p-63a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1063-3ED42-0AA0 3VM1 4P 63A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1063-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 63 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1063-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 63 A rated current and 25 kA breaking capacity, the 3VM1063-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714167067,"sku":"3VM1063-3ED42-0AA0","price":147.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1063-3ed42-0aa0.webp?v=1784360941"},{"product_id":"siemens-3vm1063-4ed32-0aa0-3vm1-3p-63a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1063-4ED32-0AA0 3VM1 3P 63A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1063-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 63 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1063-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.941 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 63 A rated current and 36 kA breaking capacity, the 3VM1063-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714199835,"sku":"3VM1063-4ED32-0AA0","price":100.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1063-4ed32-0aa0.webp?v=1784360948"},{"product_id":"siemens-3vm1063-4ed42-0aa0-3vm1-4p-63a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1063-4ED42-0AA0 3VM1 4P 63A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1063-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 63 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1063-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.182 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 63 A rated current and 36 kA breaking capacity, the 3VM1063-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714232603,"sku":"3VM1063-4ED42-0AA0","price":150.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1063-4ed42-0aa0.webp?v=1784360954"},{"product_id":"siemens-3vm1080-3ed32-0aa0-3vm1-3p-80a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1080-3ED32-0AA0 3VM1 3P 80A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1080-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 80 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1080-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.922 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 80 A rated current and 25 kA breaking capacity, the 3VM1080-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714363675,"sku":"3VM1080-3ED32-0AA0","price":101.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1080-3ed32-0aa0.webp?v=1784360961"},{"product_id":"siemens-3vm1080-3ed42-0aa0-3vm1-4p-80a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1080-3ED42-0AA0 3VM1 4P 80A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1080-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 80 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1080-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 80 A rated current and 25 kA breaking capacity, the 3VM1080-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714396443,"sku":"3VM1080-3ED42-0AA0","price":127.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1080-3ed42-0aa0.webp?v=1784360967"},{"product_id":"siemens-3vm1080-4ed32-0aa0-3vm1-3p-80a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1080-4ED32-0AA0 3VM1 3P 80A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1080-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 80 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1080-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.938 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 80 A rated current and 36 kA breaking capacity, the 3VM1080-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714429211,"sku":"3VM1080-4ED32-0AA0","price":107.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1080-4ed32-0aa0.webp?v=1784360974"},{"product_id":"siemens-3vm1080-4ed42-0aa0-3vm1-4p-80a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1080-4ED42-0AA0 3VM1 4P 80A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1080-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 80 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1080-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.181 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 80 A rated current and 36 kA breaking capacity, the 3VM1080-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714461979,"sku":"3VM1080-4ED42-0AA0","price":157.49,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1080-4ed42-0aa0.webp?v=1784360980"},{"product_id":"siemens-3vm1096-3ed32-0aa0-3vm1-3p-16a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1096-3ED32-0AA0 3VM1 3P 16A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1096-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 16 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1096-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.956 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 16 A rated current and 25 kA breaking capacity, the 3VM1096-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714494747,"sku":"3VM1096-3ED32-0AA0","price":109.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1096-3ed32-0aa0.webp?v=1784360987"},{"product_id":"siemens-3vm1096-3ed42-0aa0-3vm1-4p-16a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1096-3ED42-0AA0 3VM1 4P 16A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1096-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 16 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1096-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 16 A rated current and 25 kA breaking capacity, the 3VM1096-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714527515,"sku":"3VM1096-3ED42-0AA0","price":147.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1096-3ed42-0aa0.webp?v=1784360993"},{"product_id":"siemens-3vm1096-4ed32-0aa0-3vm1-3p-16a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1096-4ED32-0AA0 3VM1 3P 16A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1096-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 16 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1096-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.961 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 16 A rated current and 36 kA breaking capacity, the 3VM1096-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714625819,"sku":"3VM1096-4ED32-0AA0","price":123.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1096-4ed32-0aa0.webp?v=1784361000"},{"product_id":"siemens-3vm1096-4ed42-0aa0-3vm1-4p-16a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1096-4ED42-0AA0 3VM1 4P 16A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1096-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 16 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1096-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 16 A rated current and 36 kA breaking capacity, the 3VM1096-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714658587,"sku":"3VM1096-4ED42-0AA0","price":150.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1096-4ed42-0aa0.webp?v=1784361006"},{"product_id":"siemens-3vm1110-3ee32-0aa0-3vm1-3p-100a-25ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VM1110-3EE32-0AA0 3VM1 3P 100A 25kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1110-3EE32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1110-3EE32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.875 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 25 kA breaking capacity, the 3VM1110-3EE32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714691355,"sku":"3VM1110-3EE32-0AA0","price":122.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1110-3ee32-0aa0.webp?v=1784361014"},{"product_id":"siemens-3vm1110-4ee42-0aa0-3vm1-4p-100a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VM1110-4EE42-0AA0 3VM1 4P 100A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1110-4EE42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1110-4EE42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70–100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.182 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 36 kA breaking capacity, the 3VM1110-4EE42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714724123,"sku":"3VM1110-4EE42-0AA0","price":162.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1110-4ee42-0aa0.webp?v=1784361020"},{"product_id":"siemens-3vm1110-5mh32-0aa0-3vm1-3p-100a-55ka-415v-tm120m-i-molded-case-circuit-breaker","title":"Siemens 3VM1110-5MH32-0AA0 3VM1 3P 100A 55kA 415V TM120M I Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1110-5MH32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 100 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM120M I thermal-magnetic trip unit providing overload and short-circuit protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1110-5MH32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM120M — I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.983 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 100 A rated current and 55 kA breaking capacity, the 3VM1110-5MH32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM120M I trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714756891,"sku":"3VM1110-5MH32-0AA0","price":151.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1110-5mh32-0aa0.webp?v=1784361027"},{"product_id":"siemens-3vm1112-3ed32-0aa0-3vm1-3p-125a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-3ED32-0AA0 3VM1 3P 125A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.931 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 25 kA breaking capacity, the 3VM1112-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714789659,"sku":"3VM1112-3ED32-0AA0","price":144.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-3ed32-0aa0.webp?v=1784361034"},{"product_id":"siemens-3vm1112-3ed42-0aa0-3vm1-4p-125a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-3ED42-0AA0 3VM1 4P 125A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.254 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 25 kA breaking capacity, the 3VM1112-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714822427,"sku":"3VM1112-3ED42-0AA0","price":188.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-3ed42-0aa0.webp?v=1784361040"},{"product_id":"siemens-3vm1112-3ee32-0aa0-3vm1-3p-125a-25ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-3EE32-0AA0 3VM1 3P 125A 25kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-3EE32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-3EE32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.004 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 25 kA breaking capacity, the 3VM1112-3EE32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714855195,"sku":"3VM1112-3EE32-0AA0","price":160.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-3ee32-0aa0.webp?v=1784361047"},{"product_id":"siemens-3vm1112-4ed32-0aa0-3vm1-3p-125a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-4ED32-0AA0 3VM1 3P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.931 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VM1112-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619714887963,"sku":"3VM1112-4ED32-0AA0","price":158.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-4ed32-0aa0.webp?v=1784361055"},{"product_id":"siemens-3vm1112-4ed42-0aa0-3vm1-4p-125a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-4ED42-0AA0 3VM1 4P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-4ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-4ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.263 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VM1112-4ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715019035,"sku":"3VM1112-4ED42-0AA0","price":194.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-4ed42-0aa0.webp?v=1784361061"},{"product_id":"siemens-3vm1112-4ee42-0aa0-3vm1-4p-125a-36ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VM1112-4EE42-0AA0 3VM1 4P 125A 36kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-4EE42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-4EE42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87–125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.259 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 36 kA breaking capacity, the 3VM1112-4EE42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715084571,"sku":"3VM1112-4EE42-0AA0","price":292.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-4ee42-0aa0.webp?v=1784361067"},{"product_id":"siemens-3vm1112-5mh32-0aa0-3vm1-3p-125a-55ka-415v-tm120m-i-molded-case-circuit-breaker","title":"Siemens 3VM1112-5MH32-0AA0 3VM1 3P 125A 55kA 415V TM120M I Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1112-5MH32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 125 A with a breaking capacity of 55 kA (Icu) at 415 V AC (utilisation class M). It is equipped with the TM120M I thermal-magnetic trip unit providing overload and short-circuit protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1112-5MH32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM120M — I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA @415V AC (Icu, class M)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 125 A rated current and 55 kA breaking capacity, the 3VM1112-5MH32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM120M I trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715182875,"sku":"3VM1112-5MH32-0AA0","price":223.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1112-5mh32-0aa0.webp?v=1784361075"},{"product_id":"siemens-3vm1116-3ed32-0aa0-3vm1-3p-160a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1116-3ED32-0AA0 3VM1 3P 160A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1116-3ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 160 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1116-3ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 25 kA breaking capacity, the 3VM1116-3ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715313947,"sku":"3VM1116-3ED32-0AA0","price":150.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1116-3ed32-0aa0.webp?v=1784361082"},{"product_id":"siemens-3vm1116-3ed42-0aa0-3vm1-4p-160a-25ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1116-3ED42-0AA0 3VM1 4P 160A 25kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1116-3ED42-0AA0 is a four-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 160 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1116-3ED42-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 101.5 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.253 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 25 kA breaking capacity, the 3VM1116-3ED42-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715412251,"sku":"3VM1116-3ED42-0AA0","price":202.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1116-3ed42-0aa0.webp?v=1784361088"},{"product_id":"siemens-3vm1116-3ee32-0aa0-3vm1-3p-160a-25ka-415v-tm220-li-molded-case-circuit-breaker","title":"Siemens 3VM1116-3EE32-0AA0 3VM1 3P 160A 25kA 415V TM220 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1116-3EE32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 160 A with a breaking capacity of 25 kA (Icu) at 415 V AC (utilisation class N). It is equipped with the TM220 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1116-3EE32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM220 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Overload (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112–160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @415V AC (Icu, class N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.931 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 25 kA breaking capacity, the 3VM1116-3EE32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM220 LI trip unit offers adjustable overload and short-circuit settings for selectivity coordination with upstream and downstream devices.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715445019,"sku":"3VM1116-3EE32-0AA0","price":170.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1116-3ee32-0aa0.webp?v=1784361096"},{"product_id":"siemens-3vm1116-4ed32-0aa0-3vm1-3p-160a-36ka-415v-tm210-li-molded-case-circuit-breaker","title":"Siemens 3VM1116-4ED32-0AA0 3VM1 3P 160A 36kA 415V TM210 LI Molded Case Circuit Breaker","description":"\u003cp\u003eThe Siemens 3VM1116-4ED32-0AA0 is a three-pole molded case circuit breaker (MCCB) from the SENTRON 3VM1 series, rated 160 A with a breaking capacity of 36 kA (Icu) at 415 V AC (utilisation class S). It is equipped with the TM210 LI thermal-magnetic trip unit providing overload (L) and instantaneous short-circuit (I) protection. Rated for distribution and motor-feeder protection in low-voltage switchgear up to 500 V AC.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1116-4ED32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3VM1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM210 — LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @415V AC (Icu, class S)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIcu @240V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm × 76.2 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.003 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eAt 160 A rated current and 36 kA breaking capacity, the 3VM1116-4ED32-0AA0 is dimensioned for feeder, sub-distribution and motor-circuit protection in low-voltage main and sub-distribution boards. The TM210 LI trip unit provides fixed overload and short-circuit protection matched to the rated current.\u003c\/p\u003e\n\u003cp\u003eThe IEC Frame  enclosure supports fixed mounting in form-separated switchgear (form 2–4) and accepts a range of Siemens 3VA accessories — auxiliary and alarm switches, shunt and undervoltage releases, rotary and motor operators — for adaptation to the specific installation and control scheme.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619715477787,"sku":"3VM1116-4ED32-0AA0","price":207.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3vm1116-4ed32-0aa0.webp?v=1784361103"}],"url":"https:\/\/stoklink.com\/collections\/siemens-sentron-3vm.oembed?page=6","provider":"Stoklink","version":"1.0","type":"link"}