{"title":"Schneider TeSys Giga Contactors","description":"\u003cp\u003eSchneider Electric TeSys Giga contactors are high-current power contactors for large motors and heavy loads. Stoklink carries over 50 TeSys Giga items from 115 A to 800 A and 55 kW to 450 kW, in 3 pole and 4 pole versions. We ship worldwide from Turkey and quote project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-pole LC1G contactors for AC-3 motor duty, up to 800 A.\u003c\/li\u003e\n\u003cli\u003eFour-pole versions rated for AC-1 switching.\u003c\/li\u003e\n\u003cli\u003eElectronic AC\/DC coils in bands such as 48-130 V, 100-250 V and 200-500 V.\u003c\/li\u003e\n\u003cli\u003eLower frames from 115 A for mid-size motors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelect by AC-3 current and kW at the motor voltage.\u003c\/li\u003e\n\u003cli\u003eUse 4P only where the neutral must be switched.\u003c\/li\u003e\n\u003cli\u003ePick the AC\/DC coil band that covers your control supply, including its tolerance.\u003c\/li\u003e\n\u003cli\u003eCheck the busbar or lug connection space against your cable size.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhen should I use TeSys Giga instead of TeSys Deca?\u003c\/h3\u003e\u003cp\u003eUse Giga above the Deca limit of 200 A, or for motors in the upper kW range. Giga frames start at 115 A.\u003c\/p\u003e\u003ch3\u003eAre the coils AC or DC?\u003c\/h3\u003e\u003cp\u003eThe Giga items listed use AC\/DC coils in voltage bands. Check the band in the part number against your control voltage.\u003c\/p\u003e\u003ch3\u003eDo you ship contactors outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-lc1g1154ehen-tesys-giga-contactor","title":"Schneider Electric LC1G1154EHEN TeSys Giga Contactor 4P 4NO AC-1 250 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1154EHEN is a 4-pole TeSys Giga contactor rated 250 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1154EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1040 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 250 A AC-1, the LC1G1154EHEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1040 A breaking capacity and 1.1 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 48-130 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230437544219,"sku":"LC1G1154EHEN","price":431.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1154ehen-tesys-giga-contactor.jpg?v=1790901048"},{"product_id":"schneider-electric-lc1g1154kuen-tesys-giga-contactor","title":"Schneider Electric LC1G1154KUEN TeSys Giga Contactor 4P 4NO AC-1 250 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1154KUEN is a 4-pole TeSys Giga contactor rated 250 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1154KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1040 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 250 A AC-1, the LC1G1154KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1040 A breaking capacity and 1.1 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230437806363,"sku":"LC1G1154KUEN","price":431.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1154kuen-tesys-giga-contactor.jpg?v=1790900901"},{"product_id":"schneider-electric-lc1g1154lsea-tesys-giga-contactor","title":"Schneider Electric LC1G1154LSEA TeSys Giga Contactor 4P 4NO AC-1 250 A 200-500 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1154LSEA is a 4-pole TeSys Giga contactor rated 250 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1154LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1040 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 250 A AC-1, the LC1G1154LSEA is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1040 A breaking capacity and 1.1 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 200-500 V AC\/DC coil with PLC-level control and remote (not just local) contact-wear diagnosis. The remote diagnostic capability is the practical reason to pick this coil tier over the EHEN\/KUEN options when the contactor sits somewhere a technician can't walk up to read the local contact-wear indicator, such as a sealed switchgear line-up or an outdoor enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230438101275,"sku":"LC1G1154LSEA","price":495.99,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1154lsea-tesys-giga-contactor.jpg?v=1790900909"},{"product_id":"schneider-electric-lc1g115ehen-tesys-giga-contactor","title":"Schneider Electric LC1G115EHEN TeSys Giga Contactor 3P 3NO AC-3 115 A 55 kW 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G115EHEN is a 3-pole TeSys Giga contactor rated 115 A AC-3, switching motors up to 55 kW at 400 V. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.1 kA for 10 s on a short circuit on the 193 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G115EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1040 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-2-40\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 115 A AC-3 (55 kW at 400 V), the LC1G115EHEN is sized for motor starting and running duty; the 1.1 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 48-130 V AC\/DC coil keeps the design simple for panels already running a low-voltage control loop, with contact-wear status read locally at the device. Where the motor load is close to the 55 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230439018779,"sku":"LC1G115EHEN","price":307.69,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g115ehen-tesys-giga-contactor.jpg?v=1790901056"},{"product_id":"schneider-lc1g115kuen-lc1g-115a-3p-440v-contactor","title":"Schneider Electric LC1G115KUEN LC1G 3-Pole 115A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G115KUEN is a TeSys Giga series 3-pole power contactor rated at 115A and 440V, engineered for reliable motor switching and heavy industrial load control. Belonging to the proven LC1G family, this contactor delivers robust performance in demanding AC motor starter and distribution applications where dependable make-and-break switching is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G115KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting:\u003c\/strong\u003e Ideal for AC-3 duty motor starter applications in pumps, compressors, fans, and conveyor drives up to 115A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for integration into motor control centres (MCCs) and automated production line panels requiring high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Used in large air-handling units and chiller plant motor control panels demanding reliable contactor performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Applicable for resistive and inductive load switching in AC-1 category distribution boards and panel boards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230439248155,"sku":"LC1G115KUEN","price":344.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g115kuen-giga-power-contactor_958a9d8b-d27e-4b4b-9793-cf1490f87285.jpg?v=1777165996"},{"product_id":"schneider-electric-lc1g115lsea-tesys-giga-contactor","title":"Schneider Electric LC1G115LSEA TeSys Giga Contactor 3P 3NO AC-3 115 A 55 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G115LSEA is a 3-pole TeSys Giga contactor rated 115 A AC-3, switching motors up to 55 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.1 kA for 10 s on a short circuit on the 255 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G115LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1040 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 115 A AC-3 (55 kW at 400 V), the LC1G115LSEA is sized for motor starting and running duty; the 1.1 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 255 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 55 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230439543067,"sku":"LC1G115LSEA","price":354.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g115lsea-tesys-giga-contactor.jpg?v=1790900917"},{"product_id":"schneider-electric-lc1g1504kuen-tesys-giga-contactor","title":"Schneider Electric LC1G1504KUEN TeSys Giga Contactor 4P 4NO AC-1 275 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1504KUEN is a 4-pole TeSys Giga contactor rated 275 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1504KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 275 A AC-1, the LC1G1504KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1280 A breaking capacity and 1.2 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230440460571,"sku":"LC1G1504KUEN","price":484.11,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1504kuen-tesys-giga-contactor.jpg?v=1790900925"},{"product_id":"schneider-electric-lc1g1504lsea-tesys-giga-contactor","title":"Schneider Electric LC1G1504LSEA TeSys Giga Contactor 4P 4NO AC-1 275 A 200-500 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1504LSEA is a 4-pole TeSys Giga contactor rated 275 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1504LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 275 A AC-1, the LC1G1504LSEA is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1280 A breaking capacity and 1.2 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 200-500 V AC\/DC coil with PLC-level control and remote (not just local) contact-wear diagnosis. The remote diagnostic capability is the practical reason to pick this coil tier over the EHEN\/KUEN options when the contactor sits somewhere a technician can't walk up to read the local contact-wear indicator, such as a sealed switchgear line-up or an outdoor enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230440755483,"sku":"LC1G1504LSEA","price":556.58,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1504lsea-tesys-giga-contactor.jpg?v=1790900933"},{"product_id":"schneider-lc1g150kuen-lc1g-150a-3p-tesys-giga-contactor","title":"Schneider Electric LC1G150KUEN LC1G 3-Pole 150A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G150KUEN is a TeSys Giga series 3-pole power contactor rated at 150A and 440V AC, engineered for heavy-duty industrial motor switching and load control applications. As part of Schneider's TeSys Giga line, the LC1G150KUEN delivers robust performance in demanding environments where reliable contactor operation is critical for motor starters, pump controllers, and high-power electrical distribution systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G150KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line (DOL) and star-delta motor starter configurations in industrial machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Control:\u003c\/strong\u003e Suitable for switching high-current loads in HVAC, water treatment, and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Used in motor control centers (MCCs) and switchgear panels for reliable load switching at 150A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Industry:\u003c\/strong\u003e Appropriate for mining, oil \u0026amp; gas, and manufacturing environments requiring robust 3-pole contactors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230441509147,"sku":"LC1G150KUEN","price":387.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g150kuen-giga-power-contactor_07723dbb-94e6-4476-b138-64cf246253f9.jpg?v=1777166000"},{"product_id":"schneider-electric-lc1g150lsea-tesys-giga-contactor","title":"Schneider Electric LC1G150LSEA TeSys Giga Contactor 3P 3NO AC-3 150 A 75 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G150LSEA is a 3-pole TeSys Giga contactor rated 150 A AC-3, switching motors up to 75 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.2 kA for 10 s on a short circuit on the 255 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G150LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 150 A AC-3 (75 kW at 400 V), the LC1G150LSEA is sized for motor starting and running duty; the 1.2 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 255 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 75 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230441771291,"sku":"LC1G150LSEA","price":397.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g150lsea-tesys-giga-contactor.jpg?v=1790900942"},{"product_id":"schneider-electric-lc1g1854ehen-tesys-giga-contactor","title":"Schneider Electric LC1G1854EHEN TeSys Giga Contactor 4P 4NO AC-1 305 A 48-130 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1854EHEN is a 4-pole TeSys Giga contactor rated 305 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1854EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 305 A AC-1, the LC1G1854EHEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1610 A breaking capacity and 1.5 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 48-130 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230442262811,"sku":"LC1G1854EHEN","price":583.31,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1854ehen-tesys-giga-contactor.jpg?v=1790900950"},{"product_id":"schneider-electric-lc1g1854kuen-tesys-giga-contactor","title":"Schneider Electric LC1G1854KUEN TeSys Giga Contactor 4P 4NO AC-1 305 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1854KUEN is a 4-pole TeSys Giga contactor rated 305 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1854KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 305 A AC-1, the LC1G1854KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 1610 A breaking capacity and 1.5 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230442524955,"sku":"LC1G1854KUEN","price":583.31,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1854kuen-tesys-giga-contactor.jpg?v=1790900958"},{"product_id":"schneider-lc1g185kuen-lc1g-185a-3p-440v-contactor","title":"Schneider Electric LC1G185KUEN LC1G 3-Pole 185A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G185KUEN is a TeSys Giga series 3-pole power contactor rated at 185A and 440V AC, engineered for heavy-duty motor switching and industrial power control applications. Part of Schneider Electric's high-performance TeSys Giga range, the LC1G185KUEN delivers reliable switching performance in demanding industrial environments. Weighing 4.4 kg, this robust contactor is built for continuous duty in motor starter and drive control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G185KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line (DOL) and reversing motor starter configurations in industrial plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching large resistive and inductive loads in manufacturing, HVAC, and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Building:\u003c\/strong\u003e Designed for integration into motor control centres (MCC) and switchgear panels requiring high-current switching capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cycling:\u003c\/strong\u003e Built for high-frequency switching cycles in demanding industrial duty applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230443311387,"sku":"LC1G185KUEN","price":467.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g185kuen-giga-power-contactor_3a7c5e49-9248-4293-ba96-1df5cd452196.jpg?v=1777166004"},{"product_id":"schneider-electric-lc1g185lsea-tesys-giga-contactor","title":"Schneider Electric LC1G185LSEA TeSys Giga Contactor 3P 3NO AC-3 185 A 90 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G185LSEA is a 3-pole TeSys Giga contactor rated 185 A AC-3, switching motors up to 90 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.5 kA for 10 s on a short circuit on the 255 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G185LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 185 A AC-3 (90 kW at 400 V), the LC1G185LSEA is sized for motor starting and running duty; the 1.5 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 255 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 90 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230443376923,"sku":"LC1G185LSEA","price":479.36,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g185lsea-tesys-giga-contactor.jpg?v=1790900966"},{"product_id":"schneider-electric-lc1g2254ehen-tesys-giga-contactor","title":"Schneider Electric LC1G2254EHEN TeSys Giga Contactor 4P 4NO AC-1 330 A 48-130 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2254EHEN is a 4-pole TeSys Giga contactor rated 330 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2254EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2050 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 330 A AC-1, the LC1G2254EHEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2050 A breaking capacity and 1.8 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 48-130 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230443507995,"sku":"LC1G2254EHEN","price":638.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2254ehen-tesys-giga-contactor.jpg?v=1790900974"},{"product_id":"schneider-electric-lc1g2254kuen-tesys-giga-contactor","title":"Schneider Electric LC1G2254KUEN TeSys Giga Contactor 4P 4NO AC-1 330 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2254KUEN is a 4-pole TeSys Giga contactor rated 330 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 193 x 143 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2254KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2050 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 143 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 330 A AC-1, the LC1G2254KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2050 A breaking capacity and 1.8 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230443573531,"sku":"LC1G2254KUEN","price":638.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2254kuen-tesys-giga-contactor.jpg?v=1790900983"},{"product_id":"schneider-electric-lc1g225ehen-tesys-giga-contactor","title":"Schneider Electric LC1G225EHEN TeSys Giga Contactor 3P 3NO AC-3 225 A 110 kW 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G225EHEN is a 3-pole TeSys Giga contactor rated 225 A AC-3, switching motors up to 110 kW at 400 V. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.8 kA for 10 s on a short circuit on the 193 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G225EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2050 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 225 A AC-3 (110 kW at 400 V), the LC1G225EHEN is sized for motor starting and running duty; the 1.8 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 48-130 V AC\/DC coil keeps the design simple for panels already running a low-voltage control loop, with contact-wear status read locally at the device. Where the motor load is close to the 110 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444032283,"sku":"LC1G225EHEN","price":455.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g225ehen-tesys-giga-contactor.jpg?v=1790900991"},{"product_id":"schneider-lc1g225kuen-lc1g-225a-3p-tesys-giga-contactor","title":"Schneider Electric LC1G225KUEN LC1G 3-Pole 225A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G225KUEN is a TeSys Giga series 3-pole power contactor rated at 225A and 440V, designed for heavy-duty motor switching and industrial load control applications. Part of the LC1G model family, the LC1G225KUEN delivers robust AC switching performance suited to demanding environments where reliable motor starting and stopping is critical. Weighing 8.2 kg, this contactor is built for panel integration in industrial motor control centres and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G225KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing large AC motors in industrial plants and process facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centres (MCC):\u003c\/strong\u003e Suitable for integration into MCC panels for centralised motor management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Load Switching:\u003c\/strong\u003e Rated for continuous high-current switching in demanding AC-3 and AC-1 duty cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumping \u0026amp; HVAC Systems:\u003c\/strong\u003e Widely used for controlling compressors, fans, pumps, and HVAC equipment in commercial and industrial buildings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing \u0026amp; Process Automation:\u003c\/strong\u003e Used in conveyor systems, mixers, crushers, and other heavy machinery requiring reliable contactor switching.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444163355,"sku":"LC1G225KUEN","price":510.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g225kuen-giga-power-contactor_a706d224-5139-48b6-ae3a-d798e0f637ec.jpg?v=1777166008"},{"product_id":"schneider-electric-lc1g225lsea-tesys-giga-contactor","title":"Schneider Electric LC1G225LSEA TeSys Giga Contactor 3P 3NO AC-3 225 A 110 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G225LSEA is a 3-pole TeSys Giga contactor rated 225 A AC-3, switching motors up to 110 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 1.8 kA for 10 s on a short circuit on the 255 x 108 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G225LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2050 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 x 108 x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 225 A AC-3 (110 kW at 400 V), the LC1G225LSEA is sized for motor starting and running duty; the 1.8 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 255 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 110 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444359963,"sku":"LC1G225LSEA","price":523.91,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g225lsea-tesys-giga-contactor.jpg?v=1790901000"},{"product_id":"schneider-electric-lc1g2654ehen-tesys-giga-contactor","title":"Schneider Electric LC1G2654EHEN TeSys Giga Contactor 4P 4NO AC-1 385 A 48-130 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2654EHEN is a 4-pole TeSys Giga contactor rated 385 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2654EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2380 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 385 A AC-1, the LC1G2654EHEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2380 A breaking capacity and 2.2 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 48-130 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444425499,"sku":"LC1G2654EHEN","price":1135.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2654ehen-tesys-giga-contactor.jpg?v=1790901008"},{"product_id":"schneider-electric-lc1g2654kuen-tesys-giga-contactor","title":"Schneider Electric LC1G2654KUEN TeSys Giga Contactor 4P 4NO AC-1 385 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2654KUEN is a 4-pole TeSys Giga contactor rated 385 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2654KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2380 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 385 A AC-1, the LC1G2654KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2380 A breaking capacity and 2.2 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444491035,"sku":"LC1G2654KUEN","price":1135.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2654kuen-tesys-giga-contactor.jpg?v=1790901017"},{"product_id":"schneider-electric-lc1g265ehen-tesys-giga-contactor","title":"Schneider Electric LC1G265EHEN TeSys Giga Contactor 3P 3NO AC-3 265 A 132 kW 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G265EHEN is a 3-pole TeSys Giga contactor rated 265 A AC-3, switching motors up to 132 kW at 400 V. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops, ships with a 1 NO + 1 NC auxiliary block, and withstands 2.2 kA for 10 s on a short circuit on the 225 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G265EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2380 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 140 x 209 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 265 A AC-3 (132 kW at 400 V), the LC1G265EHEN is sized for motor starting and running duty; the 2.2 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 48-130 V AC\/DC coil keeps the design simple for panels already running a low-voltage control loop, with contact-wear status read locally at the device. Where the motor load is close to the 132 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444720411,"sku":"LC1G265EHEN","price":810.81,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g265ehen-tesys-giga-contactor.jpg?v=1790901025"},{"product_id":"schneider-lc1g265kuen-tesys-giga-265a-3p-contactor","title":"Schneider Electric LC1G265KUEN TeSys Giga LC1G 3-Pole 265A 440V AC Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G265KUEN is a TeSys Giga series 3-pole AC power contactor rated at 265A and 440V, engineered for heavy-duty motor control and industrial power switching applications. Part of the LC1G model family, this contactor delivers robust, reliable performance in demanding environments where high current switching is required. Weighing 8.7 kg, the LC1G265KUEN is built to handle the rigors of continuous industrial duty cycles.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G265KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty motor starting:\u003c\/strong\u003e Ideal for direct-on-line and star-delta motor starters in industrial plants, controlling large AC induction motors up to and beyond 100 kW.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower distribution switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in power distribution panels and motor control centres (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump and compressor control:\u003c\/strong\u003e Deployed in water treatment, HVAC, and process industries to manage high-power pump and compressor drives reliably.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial automation:\u003c\/strong\u003e Integrated into PLC-controlled systems for automated start\/stop sequences of large machinery and production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding services:\u003c\/strong\u003e Used in commercial HVAC systems, escalators, and lift motor control where a robust 265A contactor is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444851483,"sku":"LC1G265KUEN","price":908.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g265kuen-ac-power-contactor_f807a128-b190-4bc4-a84b-755e5b11c677.jpg?v=1777166013"},{"product_id":"schneider-electric-lc1g265lsea-tesys-giga-contactor","title":"Schneider Electric LC1G265LSEA TeSys Giga Contactor 3P 3NO AC-3 265 A 132 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G265LSEA is a 3-pole TeSys Giga contactor rated 265 A AC-3, switching motors up to 132 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 2.2 kA for 10 s on a short circuit on the 290 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G265LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2380 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 x 140 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 265 A AC-3 (132 kW at 400 V), the LC1G265LSEA is sized for motor starting and running duty; the 2.2 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 290 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 132 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230444982555,"sku":"LC1G265LSEA","price":931.99,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g265lsea-tesys-giga-contactor.jpg?v=1790901034"},{"product_id":"schneider-electric-lc1g3304kuen-tesys-giga-contactor","title":"Schneider Electric LC1G3304KUEN TeSys Giga Contactor 4P 4NO AC-1 440 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G3304KUEN is a 4-pole TeSys Giga contactor rated 440 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G3304KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2940 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 440 A AC-1, the LC1G3304KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2940 A breaking capacity and 2.65 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445310235,"sku":"LC1G3304KUEN","price":1237.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g3304kuen-tesys-giga-contactor.jpg?v=1790900883"},{"product_id":"schneider-electric-lc1g3304lsea-tesys-giga-contactor","title":"Schneider Electric LC1G3304LSEA TeSys Giga Contactor 4P 4NO AC-1 440 A 200-500 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G3304LSEA is a 4-pole TeSys Giga contactor rated 440 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G3304LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2940 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 440 A AC-1, the LC1G3304LSEA is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 2940 A breaking capacity and 2.65 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 200-500 V AC\/DC coil with PLC-level control and remote (not just local) contact-wear diagnosis. The remote diagnostic capability is the practical reason to pick this coil tier over the EHEN\/KUEN options when the contactor sits somewhere a technician can't walk up to read the local contact-wear indicator, such as a sealed switchgear line-up or an outdoor enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445441307,"sku":"LC1G3304LSEA","price":1422.63,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g3304lsea-tesys-giga-contactor.jpg?v=1790900892"},{"product_id":"schneider-lc1g330kuen-lc1g-330a-3p-tesys-giga-contactor","title":"Schneider Electric LC1G330KUEN LC1G 3-Pole 330A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G330KUEN is a TeSys Giga series 3-pole power contactor rated at 330A and 440V, engineered for heavy-duty motor switching and industrial power control applications. The LC1G contactor delivers reliable performance in demanding environments where high current switching is required, making it a trusted choice for large motor starters and industrial drive systems. Weighing 8.7 kg, the LC1G330KUEN is a robust, high-capacity contactor suited for use across a wide range of industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G330KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Motor Starting:\u003c\/strong\u003e Ideal for AC-3 and AC-1 utilization categories in heavy-duty motor starter configurations requiring high current capacity up to 330A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Switching:\u003c\/strong\u003e Suitable for switching large resistive and inductive loads in manufacturing plants, utilities, and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Commonly integrated into MCC panels for centralized motor management in industrial facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Control:\u003c\/strong\u003e Frequently used for starting and stopping large pumps, compressors, and fans in HVAC, water treatment, and oil \u0026amp; gas applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Speed Drive Bypass:\u003c\/strong\u003e Deployed as a bypass or line contactor in VFD installations to provide direct-on-line backup switching capability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445637915,"sku":"LC1G330KUEN","price":990.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g330kuen-giga-power-contactor_86a653be-3106-421c-bf79-e17f02015b26.jpg?v=1777166017"},{"product_id":"schneider-electric-lc1g330lsea-tesys-giga-contactor","title":"Schneider Electric LC1G330LSEA TeSys Giga Contactor 3P 3NO AC-3 330 A 160 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G330LSEA is a 3-pole TeSys Giga contactor rated 330 A AC-3, switching motors up to 160 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 2.65 kA for 10 s on a short circuit on the 290 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G330LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2940 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 x 140 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 330 A AC-3 (160 kW at 400 V), the LC1G330LSEA is sized for motor starting and running duty; the 2.65 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 290 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 160 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445703451,"sku":"LC1G330LSEA","price":1016.93,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g330lsea-tesys-giga-contactor.jpg?v=1790900900"},{"product_id":"schneider-electric-lc1g4004kuen-tesys-giga-contactor","title":"Schneider Electric LC1G4004KUEN TeSys Giga Contactor 4P 4NO AC-1 550 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G4004KUEN is a 4-pole TeSys Giga contactor rated 550 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G4004KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3480 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 550 A AC-1, the LC1G4004KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 3480 A breaking capacity and 3.6 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445768987,"sku":"LC1G4004KUEN","price":1699.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g4004kuen-tesys-giga-contactor.jpg?v=1790900908"},{"product_id":"schneider-electric-lc1g4004lsea-tesys-giga-contactor","title":"Schneider Electric LC1G4004LSEA TeSys Giga Contactor 4P 4NO AC-1 550 A 200-500 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G4004LSEA is a 4-pole TeSys Giga contactor rated 550 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G4004LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3480 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 550 A AC-1, the LC1G4004LSEA is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 3480 A breaking capacity and 3.6 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 200-500 V AC\/DC coil with PLC-level control and remote (not just local) contact-wear diagnosis. The remote diagnostic capability is the practical reason to pick this coil tier over the EHEN\/KUEN options when the contactor sits somewhere a technician can't walk up to read the local contact-wear indicator, such as a sealed switchgear line-up or an outdoor enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230445900059,"sku":"LC1G4004LSEA","price":1954.26,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g4004lsea-tesys-giga-contactor.jpg?v=1790900916"},{"product_id":"schneider-electric-lc1g400ehen-tesys-giga-contactor","title":"Schneider Electric LC1G400EHEN TeSys Giga Contactor 3P 3NO AC-3 400 A 200 kW 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G400EHEN is a 3-pole TeSys Giga contactor rated 400 A AC-3, switching motors up to 200 kW at 400 V. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops, ships with a 1 NO + 1 NC auxiliary block, and withstands 3.6 kA for 10 s on a short circuit on the 225 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G400EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3480 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 140 x 209 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 400 A AC-3 (200 kW at 400 V), the LC1G400EHEN is sized for motor starting and running duty; the 3.6 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 48-130 V AC\/DC coil keeps the design simple for panels already running a low-voltage control loop, with contact-wear status read locally at the device. Where the motor load is close to the 200 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446031131,"sku":"LC1G400EHEN","price":1097.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g400ehen-tesys-giga-contactor.jpg?v=1790900925"},{"product_id":"schneider-lc1g400kuen-lc1g-400a-3p-tesys-giga-contactor","title":"Schneider Electric LC1G400KUEN LC1G 3-Pole 400A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G400KUEN is a TeSys Giga series 3-pole power contactor rated at 400A and 440V, engineered for heavy-duty industrial motor control and high-current switching applications. Part of the LC1G model family, this contactor delivers reliable performance in demanding environments where robust, high-capacity switching is essential. Weighing 8.2 kg, the LC1G400KUEN is built to handle the rigorous demands of industrial power distribution and large motor starting circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G400KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty motor starting:\u003c\/strong\u003e Ideal for controlling large AC motors in pumping stations, compressors, conveyors, and industrial fans requiring high-current switching capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower distribution switching:\u003c\/strong\u003e Suitable for switching large electrical loads in industrial plants, manufacturing facilities, and infrastructure projects where 400A capacity is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control centers (MCC):\u003c\/strong\u003e The LC1G400KUEN integrates into MCC panels for centralized motor management in process industries including oil \u0026amp; gas, water treatment, and mining.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC and building services:\u003c\/strong\u003e Used in large commercial and industrial HVAC systems for controlling high-power motors and compressors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446096667,"sku":"LC1G400KUEN","price":1228.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g400kuen-giga-power-contactor_f87096ad-a8a7-488c-9f5b-215f7eb7afbb.jpg?v=1777166021"},{"product_id":"schneider-electric-lc1g400lsea-tesys-giga-contactor","title":"Schneider Electric LC1G400LSEA TeSys Giga Contactor 3P 3NO AC-3 400 A 200 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G400LSEA is a 3-pole TeSys Giga contactor rated 400 A AC-3, switching motors up to 200 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 3.6 kA for 10 s on a short circuit on the 290 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G400LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3480 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 x 140 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 400 A AC-3 (200 kW at 400 V), the LC1G400LSEA is sized for motor starting and running duty; the 3.6 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 290 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 200 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446162203,"sku":"LC1G400LSEA","price":1261.06,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g400lsea-tesys-giga-contactor.jpg?v=1790900935"},{"product_id":"schneider-electric-lc1g5004ehen-tesys-giga-contactor","title":"Schneider Electric LC1G5004EHEN TeSys Giga Contactor 4P 4NO AC-1 700 A 48-130 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G5004EHEN is a 4-pole TeSys Giga contactor rated 700 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G5004EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4600 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 700 A AC-1, the LC1G5004EHEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 4600 A breaking capacity and 4.0 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 48-130 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446293275,"sku":"LC1G5004EHEN","price":2696.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g5004ehen-tesys-giga-contactor.jpg?v=1790900943"},{"product_id":"schneider-electric-lc1g5004kuen-tesys-giga-contactor","title":"Schneider Electric LC1G5004KUEN TeSys Giga Contactor 4P 4NO AC-1 700 A 100-250 V AC\/DC V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G5004KUEN is a 4-pole TeSys Giga contactor rated 700 A AC-1 at up to 440 V, for heavy resistive and power-switching duty such as heater banks, capacitor banks or bypass circuits. It runs on a 100-250 V AC\/DC wide-band electronic coil matched to standard 110\/230 V control transformers and ships with a 1 NO + 1 NC auxiliary block factory-fitted on the 225 x 185 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G5004KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower switching (AC-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4600 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower circuit busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 185 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 700 A AC-1, the LC1G5004KUEN is sized for power-switching and resistive duty — heater banks, capacitor banks, bus-tie and bypass circuits — rather than motor starting; the 4600 A breaking capacity and 4.0 kA 10 s short-time withstand are what matter for coordinating with an upstream breaker on this frame. It carries a 100-250 V AC\/DC coil. Local contact-wear diagnosis (CWD) is read directly at the device; where the panel is inaccessible or centrally monitored, the LSEA electronic-coil variant of the same current frame adds remote diagnostics without changing the mechanical footprint.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446358811,"sku":"LC1G5004KUEN","price":2696.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g5004kuen-tesys-giga-contactor.jpg?v=1790900952"},{"product_id":"schneider-electric-lc1g500ehen-tesys-giga-contactor","title":"Schneider Electric LC1G500EHEN TeSys Giga Contactor 3P 3NO AC-3 500 A 250 kW 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G500EHEN is a 3-pole TeSys Giga contactor rated 500 A AC-3, switching motors up to 250 kW at 400 V. It runs on a 48-130 V AC\/DC wide-band electronic coil for low-voltage control loops, ships with a 1 NO + 1 NC auxiliary block, and withstands 4.0 kA for 10 s on a short circuit on the 225 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G500EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4600 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 x 140 x 209 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 500 A AC-3 (250 kW at 400 V), the LC1G500EHEN is sized for motor starting and running duty; the 4.0 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 48-130 V AC\/DC coil keeps the design simple for panels already running a low-voltage control loop, with contact-wear status read locally at the device. Where the motor load is close to the 250 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446620955,"sku":"LC1G500EHEN","price":1781.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g500ehen-tesys-giga-contactor.jpg?v=1790900960"},{"product_id":"schneider-lc1g500kuen-tesys-giga-500a-3p-contactor","title":"Schneider Electric LC1G500KUEN TeSys Giga 3-Pole 500A 440V AC Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G500KUEN is a TeSys Giga series 3-pole AC power contactor rated at 500A and 440V, engineered for demanding industrial motor control and power switching applications. Designed to handle high-current loads with reliability and precision, the LC1G500KUEN delivers the robust performance expected from Schneider Electric's flagship TeSys Giga contactor range. Weighing 17.3 kg, this contactor is built for panel-mounted installations in heavy-duty environments where continuous high-current operation is required.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G500KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty motor control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing large AC motors in manufacturing, pumping, and compressor stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower distribution switching:\u003c\/strong\u003e Suitable for switching high-current power circuits in industrial distribution panels and motor control centres (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrastructure \u0026amp; utilities:\u003c\/strong\u003e Used in water treatment plants, HVAC systems, mining operations, and oil \u0026amp; gas facilities requiring reliable high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial automation:\u003c\/strong\u003e Compatible with PLC-driven control systems and automation architectures that demand robust, high-cycle contactor performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446817563,"sku":"LC1G500KUEN","price":1996.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g500kuen-ac-power-contactor_4c797c65-b9e4-4a67-ac13-4937324aa998.jpg?v=1777166025"},{"product_id":"schneider-electric-lc1g500lsea-tesys-giga-contactor","title":"Schneider Electric LC1G500LSEA TeSys Giga Contactor 3P 3NO AC-3 500 A 250 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G500LSEA is a 3-pole TeSys Giga contactor rated 500 A AC-3, switching motors up to 250 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 4.0 kA for 10 s on a short circuit on the 290 x 140 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G500LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4600 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 x 140 x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 500 A AC-3 (250 kW at 400 V), the LC1G500LSEA is sized for motor starting and running duty; the 4.0 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 290 mm-tall frame sits in a line-up a technician can't walk up to on every shift. Where the motor load is close to the 250 kW boundary, the next current step up in the same Giga 3-pole family keeps the AC-3 rating comfortably inside its nameplate rather than at the ceiling.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230446883099,"sku":"LC1G500LSEA","price":2048.11,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g500lsea-tesys-giga-contactor.jpg?v=1790900968"},{"product_id":"schneider-lc1g630kuen-lc1g-630a-3p-tesys-giga-contactor","title":"Schneider Electric LC1G630KUEN LC1G 3-Pole 630A 440V TeSys Giga Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G630KUEN is a TeSys Giga series 3-pole power contactor rated at 630A and 440V, designed for heavy-duty motor switching and industrial load control applications. As part of the proven TeSys Giga range, the LC1G630KUEN delivers reliable performance in demanding AC power distribution environments where high current switching is required. Weighing 14.2 kg, this robust contactor is built to handle the most challenging industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G630KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty motor starting:\u003c\/strong\u003e Ideal for AC-3 and AC-1 utilization categories in large motor starter contactor configurations up to 630A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial power distribution:\u003c\/strong\u003e Suited for switching large resistive and inductive loads in manufacturing plants, water treatment facilities, and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor controller panels:\u003c\/strong\u003e Commonly integrated into motor control centres (MCCs) and motor starter assemblies requiring high-current AC contactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump and compressor control:\u003c\/strong\u003e Reliable switching for large pump motors, compressors, and HVAC systems where a robust power contactor is essential.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated current of the LC1G630KUEN?\u003c\/strong\u003e The LC1G630KUEN is rated at 630A, making it one of the highest-capacity contactors in the TeSys Giga series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage is the LC1G630KUEN rated for?\u003c\/strong\u003e This contactor is rated at 440V AC, suitable for standard industrial three-phase power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles does the LC1G630KUEN have?\u003c\/strong\u003e The LC1G630KUEN is a 3-pole contactor designed for three-phase motor and load switching applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat series does the LC1G630KUEN belong to?\u003c\/strong\u003e It belongs to the Schneider Electric TeSys Giga series, engineered for high-power industrial contactor applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230447145243,"sku":"LC1G630KUEN","price":2404.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g630kuen-giga-power-contactor_0c8598e8-4615-4f29-b734-8768b1780f8c.jpg?v=1777166030"},{"product_id":"schneider-electric-lc1g630lsea-tesys-giga-contactor","title":"Schneider Electric LC1G630LSEA TeSys Giga Contactor 3P 3NO AC-3 630 A 335 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G630LSEA is a 3-pole TeSys Giga contactor rated 630 A AC-3, switching motors up to 335 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 5.05 kA for 10 s on a short circuit on the 388.5 x 211 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G630LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1050 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5550 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.05 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e388.5 x 211 x 266 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 630 A AC-3 (335 kW at 400 V), the LC1G630LSEA is sized for motor starting and running duty; the 5.05 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 388.5 mm-tall frame sits in a line-up a technician can't walk up to on every shift. At this frame size the mechanical durability drops to 1,800,000 cycles rather than the 3,000,000 of the smaller Giga frames — worth checking against the expected duty cycle on applications with frequent starts.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230447243547,"sku":"LC1G630LSEA","price":2466.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g630lsea-tesys-giga-contactor.jpg?v=1790900977"},{"product_id":"schneider-lc1g800kuen-lz1h-tesys-giga-800a-3p-contactor","title":"Schneider Electric LC1G800KUEN LZ1H TeSys Giga 3-Pole 800A 440V Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G800KUEN is a TeSys Giga series 3-pole power contactor rated at 800A and 440V AC, engineered for heavy-duty motor starting and industrial load switching applications. Part of the renowned TeSys Giga family, the LC1G800KUEN (model LZ1H) delivers robust, reliable switching performance in demanding industrial environments where high-current control is critical. Weighing just 0.212 kg, this contactor combines high current capacity with a compact, efficient design suited to modern switchgear panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G800KUEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLZ1H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.212 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty motor starting:\u003c\/strong\u003e Ideal for AC-3 direct-on-line starting of large induction motors in industrial plants, pumping stations, and compressor rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower distribution switching:\u003c\/strong\u003e Suitable for switching large resistive and inductive loads in main distribution boards and motor control centres (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial machinery:\u003c\/strong\u003e Used in steel mills, mining equipment, water treatment facilities, and large HVAC systems requiring reliable high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control centres:\u003c\/strong\u003e Integrates seamlessly into TeSys Giga-based MCC assemblies for centralised motor management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the rated current of the LC1G800KUEN?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1G800KUEN is rated at 800A, making it suitable for very large motor and load switching applications.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow many poles does this contactor have?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThis is a 3-pole contactor, designed for three-phase AC power circuits.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat series does the LC1G800KUEN belong to?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt belongs to the Schneider Electric TeSys Giga series, a range of high-power contactors for industrial applications.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the model number for this contactor?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe model number is LZ1H, which identifies the specific variant within the TeSys Giga family.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230447374619,"sku":"LC1G800KUEN","price":2951.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g800kuen-440v-power-contactor_797cf199-e66a-4e5e-bd44-a3c5ba9bd60a.jpg?v=1777166034"},{"product_id":"schneider-electric-lc1g800lsea-tesys-giga-contactor","title":"Schneider Electric LC1G800LSEA TeSys Giga Contactor 3P 3NO AC-3 800 A 450 kW 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G800LSEA is a 3-pole TeSys Giga contactor rated 800 A AC-3, switching motors up to 450 kW at 400 V. It runs on a 200-500 V AC\/DC wide-band electronic coil with PLC-level control input and remote contact-wear diagnosis, ships with a 1 NO + 1 NC auxiliary block, and withstands 5.5 kA for 10 s on a short circuit on the 388.5 x 211 mm Giga frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G800LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContactor application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor control (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC 50\/60 Hz \/ ≤ 460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at \u0026lt; 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie, AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1050 A at \u0026lt; 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5870 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kA for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A aM at ≤ 440 V (motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical durability (B10d)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800,000 cycles (EN\/ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds (IEC 60529 \/ VDE 0106)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e388.5 x 211 x 266 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated 800 A AC-3 (450 kW at 400 V), the LC1G800LSEA is sized for motor starting and running duty; the 5.5 kA short-time withstand for 10 s is the figure to check against the upstream breaker's let-through when coordinating selectivity on a motor feeder. Its 200-500 V AC\/DC coil accepts PLC-level control signals directly and reports contact wear remotely, which matters when this 388.5 mm-tall frame sits in a line-up a technician can't walk up to on every shift. At this frame size the mechanical durability drops to 1,800,000 cycles rather than the 3,000,000 of the smaller Giga frames — worth checking against the expected duty cycle on applications with frequent starts.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230447440155,"sku":"LC1G800LSEA","price":3028.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g800lsea-tesys-giga-contactor.jpg?v=1790900985"},{"product_id":"schneider-electric-lc1g1504ehen-tesys-giga-4p-contactor","title":"Schneider Electric LC1G1504EHEN TeSys Giga Contactor 4P 4NO AC-1 275 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1504EHEN is a 4-pole TeSys Giga high-power contactor rated 275 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 48-130 V AC\/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 143 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1504EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481922038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (power switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kA (10 s) \/ 0.6 kA (1 min) \/ 0.35 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A aM (≤440 V) \/ 315 A gG (≤690 V) \/ 300 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W AC-1 \/ 5 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640 VA AC \/ 445 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 300 cyc\/h AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 mm x 143 mm x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4P\/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 48-130 V AC\/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077037478171,"sku":"LC1G1504EHEN","price":484.11,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1504ehen-tesys-giga-4p-contactor.jpg?v=1790875015"},{"product_id":"schneider-electric-lc1g150ehen-tesys-giga-3p-contactor","title":"Schneider Electric LC1G150EHEN TeSys Giga Contactor 3P 3NO AC-3 150 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G150EHEN is a 3-pole TeSys Giga high-power contactor rated 150 A AC-3 (75 kW at 400 V) for direct motor starting, with a separate AC-1 rating of 275 A for pure power switching. It runs on a 48-130 V AC\/DC wide-band electronic coil with built-in peak limiting and ships with a 1 NO + 1 NC auxiliary contact block, mounted on a plate 108 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G150EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481921833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 \/ AC-3 \/ AC-3e \/ AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kA (10 s) \/ 0.6 kA (1 min) \/ 0.35 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A aM (≤440 V) \/ 315 A gG (≤690 V) \/ 300 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W AC-1 \/ 5 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 150 cyc\/h AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 mm x 108 mm x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-2-40\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe AC-3 rating of 150 A (75 kW at 400 V) sizes this contactor for direct-on-line motor starting; its AC-1 rating of 275 A applies only to resistive switching, not motor duty. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. Pick a higher-current Giga variant in the same range if the motor's AC-3 current exceeds this frame's rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077038461211,"sku":"LC1G150EHEN","price":345.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g150ehen-tesys-giga-3p-contactor.jpg?v=1790875029"},{"product_id":"schneider-electric-lc1g1854lsea-tesys-giga-4p-contactor","title":"Schneider Electric LC1G1854LSEA TeSys Giga Contactor 4P 4NO AC-1 305 A 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G1854LSEA is a 4-pole TeSys Giga high-power contactor rated 305 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 200-500 V AC\/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 143 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G1854LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481922748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (power switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2310 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kA (10 s) \/ 0.74 kA (1 min) \/ 0.4 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A aM (≤440 V) \/ 315 A gG (≤690 V) \/ 300 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 W AC-1 \/ 6 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e295 VA AC \/ 215 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 300 cyc\/h AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 mm x 143 mm x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4P\/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 200-500 V AC\/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077039378715,"sku":"LC1G1854LSEA","price":670.63,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g1854lsea-tesys-giga-4p-contactor.jpg?v=1790875044"},{"product_id":"schneider-electric-lc1g185ehen-tesys-giga-3p-contactor","title":"Schneider Electric LC1G185EHEN TeSys Giga Contactor 3P 3NO AC-3 185 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G185EHEN is a 3-pole TeSys Giga high-power contactor rated 185 A AC-3 (90 kW at 400 V) for direct motor starting, with a separate AC-1 rating of 305 A for pure power switching. It runs on a 48-130 V AC\/DC wide-band electronic coil with built-in peak limiting and ships with a 1 NO + 1 NC auxiliary contact block, mounted on a plate 108 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G185EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481921840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 \/ AC-3 \/ AC-3e \/ AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1610 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2310 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kA (10 s) \/ 0.74 kA (1 min) \/ 0.4 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A aM (≤440 V) \/ 315 A gG (≤690 V) \/ 300 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 W AC-1 \/ 6 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 150 cyc\/h AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193 mm x 108 mm x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-2-40\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe AC-3 rating of 185 A (90 kW at 400 V) sizes this contactor for direct-on-line motor starting; its AC-1 rating of 305 A applies only to resistive switching, not motor duty. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. Pick a higher-current Giga variant in the same range if the motor's AC-3 current exceeds this frame's rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077041213723,"sku":"LC1G185EHEN","price":416.99,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g185ehen-tesys-giga-3p-contactor.jpg?v=1790875060"},{"product_id":"schneider-electric-lc1g2254lsea-tesys-giga-4p-contactor","title":"Schneider Electric LC1G2254LSEA TeSys Giga Contactor 4P 4NO AC-1 330 A 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2254LSEA is a 4-pole TeSys Giga high-power contactor rated 330 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 200-500 V AC\/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 143 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2254LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481922755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (power switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2050 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2720 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kA (10 s) \/ 0.85 kA (1 min) \/ 0.44 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A aM (≤440 V) \/ 400 A gG (≤690 V) \/ 400 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 W AC-1 \/ 8 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e295 VA AC \/ 215 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 300 cyc\/h AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 mm x 143 mm x 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4P\/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 200-500 V AC\/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077041803547,"sku":"LC1G2254LSEA","price":734.18,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2254lsea-tesys-giga-4p-contactor.jpg?v=1790875075"},{"product_id":"schneider-electric-lc1g2654lsea-tesys-giga-4p-contactor","title":"Schneider Electric LC1G2654LSEA TeSys Giga Contactor 4P 4NO AC-1 385 A 200-500 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G2654LSEA is a 4-pole TeSys Giga high-power contactor rated 385 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 200-500 V AC\/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 185 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G2654LSEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481922762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (power switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-500 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2380 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3320 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kA (10 s) \/ 0.95 kA (1 min) \/ 0.48 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A aM (≤440 V) \/ 400 A gG (≤690 V) \/ 450 A UL Type J (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 W AC-1 \/ 11 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e530 VA AC \/ 300 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 300 cyc\/h AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mm x 185 mm x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4P\/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 200-500 V AC\/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077046653211,"sku":"LC1G2654LSEA","price":1305.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g2654lsea-tesys-giga-4p-contactor.jpg?v=1790875091"},{"product_id":"schneider-electric-lc1g3304ehen-tesys-giga-4p-contactor","title":"Schneider Electric LC1G3304EHEN TeSys Giga Contactor 4P 4NO AC-1 440 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G3304EHEN is a 4-pole TeSys Giga high-power contactor rated 440 A AC-1 at up to 440 V, built for heavy power-switching duty rather than motor AC-3 starting. It runs on a 48-130 V AC\/DC wide-band electronic coil with built-in peak limiting, ships with a 1 NO + 1 NC auxiliary contact block and local Contact Wear Diagnosis, and mounts on a plate 185 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G3304EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481922076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (power switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2940 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3830 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65 kA (10 s) \/ 1.3 kA (1 min) \/ 0.75 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A aM (≤440 V) \/ 500 A gG (≤690 V) \/ 600 A UL Type L (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W AC-1 \/ 16 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e780 VA AC \/ 695 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 300 cyc\/h AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 mm x 185 mm x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4P\/4NO contact arrangement with AC-1-only duty targets heavy resistive or power-distribution switching rather than three-phase motor starting; for motor AC-3 duty at a comparable frame size, pick the corresponding 3-pole Giga variant instead. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. The 48-130 V AC\/DC coil spans the whole band without a separate coil code per voltage, which simplifies sourcing across regions.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077050093851,"sku":"LC1G3304EHEN","price":1237.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g3304ehen-tesys-giga-4p-contactor.jpg?v=1790875104"},{"product_id":"schneider-electric-lc1g330ehen-tesys-giga-3p-contactor","title":"Schneider Electric LC1G330EHEN TeSys Giga Contactor 3P 3NO AC-3 330 A 48-130 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1G330EHEN is a 3-pole TeSys Giga high-power contactor rated 330 A AC-3 (160 kW at 400 V) for direct motor starting, with a separate AC-1 rating of 440 A for pure power switching. It runs on a 48-130 V AC\/DC wide-band electronic coil with built-in peak limiting and ships with a 1 NO + 1 NC auxiliary contact block, mounted on a plate 140 mm wide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G330EHEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Giga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481921871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 \/ AC-3 \/ AC-3e \/ AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1000 V AC 50\/60 Hz \/ ≤460 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-3 (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 A at ≤440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, AC-1 (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 A at ≤1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48-130 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2940 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity (Irms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3830 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65 kA (10 s) \/ 1.3 kA (1 min) \/ 0.75 kA (10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A aM (≤440 V) \/ 500 A gG (≤690 V) \/ 600 A UL Type L (≤600 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W AC-1 \/ 16 W AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 cyc\/h AC-3 \/ 150 cyc\/h AC-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X front face with shrouds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 mm x 140 mm x 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEU-RO-MR by DNV-GL\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-4-1\u003c\/li\u003e\n\u003cli\u003eJIS C8201-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-1\u003c\/li\u003e\n\u003cli\u003eIEC 60335-2-40\u003c\/li\u003e\n\u003cli\u003eUL 60335-1\u003c\/li\u003e\n\u003cli\u003eUL 60335-2-40\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe AC-3 rating of 330 A (160 kW at 400 V) sizes this contactor for direct-on-line motor starting; its AC-1 rating of 440 A applies only to resistive switching, not motor duty. Local Contact Wear Diagnosis flags power-contact wear before failure, and the switching module can be replaced in place without removing busbars. Pick a higher-current Giga variant in the same range if the motor's AC-3 current exceeds this frame's rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077053665563,"sku":"LC1G330EHEN","price":884.47,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1g330ehen-tesys-giga-3p-contactor.jpg?v=1790875117"}],"url":"https:\/\/stoklink.com\/collections\/schneider-tesys-giga.oembed","provider":"Stoklink","version":"1.0","type":"link"}