{"title":"Schneider TeSys Deca Contactors","description":"\u003cp\u003eSchneider Electric TeSys Deca contactors are modular power contactors for motor control and load switching. Stoklink offers over 200 TeSys Deca items from 9 A to 200 A and 4 kW to 75 kW, in 3 pole and 4 pole versions. We ship worldwide from Turkey and quote project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLC1D three-pole contactors, rated for AC-3 duty.\u003c\/li\u003e\n\u003cli\u003eFour-pole versions for AC-1 switching of four-wire loads.\u003c\/li\u003e\n\u003cli\u003eA wide choice of AC and DC coil voltages, set by the code at the end of the part number.\u003c\/li\u003e\n\u003cli\u003eModels with snap-in or EverLink terminals, as listed in the titles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePick the frame by AC-3 current at your voltage. The digits after LC1D give the rated current.\u003c\/li\u003e\n\u003cli\u003eRead the coil code at the end of the part number. It sets voltage and AC or DC.\u003c\/li\u003e\n\u003cli\u003eChoose 3P for motors and 4P for neutral switching.\u003c\/li\u003e\n\u003cli\u003ePlan add-on auxiliary blocks and overload relays from the same series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eHow do I read an LC1D part number?\u003c\/h3\u003e\u003cp\u003eLC1D is the series, the next digits give the AC-3 current, and the letters at the end give the coil voltage code.\u003c\/p\u003e\u003ch3\u003eCan I swap the coil on a TeSys Deca contactor?\u003c\/h3\u003e\u003cp\u003eCoils are replaceable within a frame. Use the coil reference listed for that exact contactor size.\u003c\/p\u003e\u003ch3\u003eDo you ship contactors outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"schneider-lc1d09b7-tesys-deca-9a-3p-contactor","title":"Schneider Electric LC1D09B7 TeSys Deca 3-Pole 9A 480VAC Coil 24V AC-3 Motor Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09B7 is a TeSys Deca series 3-pole AC contactor rated at 9A and 480VAC, designed for reliable motor switching and control in industrial applications. With a 24V AC coil voltage and a 5HP power rating, this contactor delivers robust performance for AC-3 utilization category loads. Engineered to IEC standards, the LC1D09B7 is a compact, dependable power contactor suitable for motor starter panels and control systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09B7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in compliance with IEC standards for industrial contactors and motor control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starting and stopping in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment and pump control panels\u003c\/li\u003e\n  \u003cli\u003eConveyor and compressor motor control\u003c\/li\u003e\n  \u003cli\u003eMachine tool and packaging line power switching\u003c\/li\u003e\n  \u003cli\u003eMotor starter assemblies with thermal overload relays\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337208603,"sku":"LC1D09B7","price":27.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09b7-ac-3-motor-contactor_1736acb2-3e38-4f18-91e3-c293977a705e.jpg?v=1777165557"},{"product_id":"schneider-lc1d09bd-tesvs-d-9a-3p-24vdc-contactor","title":"Schneider Electric LC1D09BD TeSys D 3P 9A 4kW 24VDC Coil AC-3 Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09BD is a TeSys D series 3-pole AC power contactor rated 9A (AC-3, ≤440V AC) with a 24V DC coil, delivering 4kW motor switching capability at 380–400V AC 50\/60Hz. Designed for industrial motor control and power switching applications, the LC1D09BD carries a comprehensive set of international certifications including IEC 60947-4-1, UL 508, and CSA, making it suitable for global deployments. Its compact footprint — 77mm H × 45mm W × 95mm D — supports both DIN rail and plate mounting for flexible panel integration.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09BD\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys D\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-3, ≤440V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690V AC \/ ≤300V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 380–400V 50\/60Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A @ 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail \/ Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment (USA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Industrial Control Equipment (Canada)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor-starters (Europe)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements (Europe)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e International standard for contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e International standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP rating)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-30:\u003c\/strong\u003e Environmental testing — damp heat, cyclic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60695-2-1:\u003c\/strong\u003e Fire hazard testing — glow-wire test\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN\/ISO 13849-1:\u003c\/strong\u003e Safety of machinery — safety-related parts of control systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine\/industrial approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas marine\/offshore approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGL:\u003c\/strong\u003e Germanischer Lloyd marine approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGOST:\u003c\/strong\u003e Russian\/CIS standards certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR (Lloyds Register of Shipping):\u003c\/strong\u003e Marine equipment approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL94 V1:\u003c\/strong\u003e Flammability rating for plastic enclosure materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances (EU Directive 2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Chemical safety regulation compliance (EU SVHC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect-on-line (DOL) starting of three-phase induction motors up to 4kW \/ 400V\u003c\/li\u003e\n  \u003cli\u003eStar-delta motor starter circuits in pump and fan applications\u003c\/li\u003e\n  \u003cli\u003eReversing contactor assemblies for conveyor and hoist control\u003c\/li\u003e\n  \u003cli\u003ePLC-controlled switching in automated production lines\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore panel boards (DNV, LR, BV, GL, RINA approved)\u003c\/li\u003e\n  \u003cli\u003eHVAC compressor and fan motor control\u003c\/li\u003e\n  \u003cli\u003eMachine tool and industrial automation panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337470747,"sku":"LC1D09BD","price":39.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09bd-ac-3-power-contactor_ca016fce-1474-4c4a-9313-acad110d2658.jpg?v=1777165562"},{"product_id":"schneider-lc1d09bl-tesys-deca-9a-3p-contactor","title":"Schneider Electric LC1D09BL TeSys Deca 3-Pole 9A 480V AC 100kA Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09BL is a TeSys Deca series 3-pole contactor rated at 9A and 480V AC, designed for reliable motor switching and control in industrial applications. With a breaking capacity of 100 kA and a 5HP power rating, the LC1D09BL delivers robust performance for motor starter and power switching duties. Weighing just 0.32 kg, this compact contactor is well-suited for panel builders and OEMs requiring high-density installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for switching and controlling AC induction motors up to 5HP in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Commonly used in direct-on-line (DOL) and star-delta motor starter configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for resistive and inductive load switching in control panels and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Panel Building:\u003c\/strong\u003e Compact form factor makes the LC1D09BL an excellent choice for high-density control panel designs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337601819,"sku":"LC1D09BL","price":34.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09bl-ac-100ka-contactor_7db185e2-0c9b-4b34-b94f-93f553543890.jpg?v=1777165566"},{"product_id":"schneider-electric-lc1d09d7-contactor","title":"Schneider Electric LC1D09D7 TeSys Deca Contactor 3P 3NO AC-3 9 A 42 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09D7 is a 3-pole TeSys Deca contactor rated 9 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 4 kW at 400 V. It carries a 42 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09D7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110348712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3 it covers motors up to 4 kW at 400 V; The 42 V AC coil matches low-voltage control transformers used where reduced control-circuit voltage is a panel safety requirement. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337798427,"sku":"LC1D09D7","price":22.22,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09d7-contactor.jpg?v=1790900933"},{"product_id":"schneider-lc1d09e7-tesys-deca-9a-3p-480v-contactor","title":"Schneider Electric LC1D09E7 TeSys Deca 3-Pole 9A 480V AC Coil 5HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09E7 is a TeSys Deca series 3-pole power contactor rated at 9A and 480V AC, designed for reliable motor switching and control in industrial applications. With a 5HP power rating and an impressive 100kA SCCR (Short Circuit Current Rating), this AC contactor delivers robust performance in demanding environments. It is an ideal motor starter contactor for use in machine control panels, HVAC systems, and industrial automation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09E7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Coil)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC standards for industrial contactors and motor control equipment, ensuring safety and interoperability in global installations.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor starting and switching in industrial machinery and conveyor systems\u003c\/li\u003e\n\u003cli\u003eHVAC and refrigeration compressor control\u003c\/li\u003e\n\u003cli\u003ePump and fan motor control panels\u003c\/li\u003e\n\u003cli\u003eFactory automation and process control switchgear\u003c\/li\u003e\n\u003cli\u003eLight and capacitor bank switching\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat is the coil voltage of the LC1D09E7?\u003c\/strong\u003e\u003cbr\u003eThe LC1D09E7 contactor has a coil voltage of 480V AC, making it suitable for direct integration into 480V power systems without an additional control transformer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat motor power can the LC1D09E7 handle?\u003c\/strong\u003e\u003cbr\u003eThis TeSys Deca contactor is rated for up to 5HP motor loads at 480V AC, suitable for small to medium industrial motor applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the LC1D09E7 IEC certified?\u003c\/strong\u003e\u003cbr\u003eYes, the LC1D09E7 is designed and tested in compliance with IEC standards for contactors and motor starters.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the SCCR of the LC1D09E7?\u003c\/strong\u003e\u003cbr\u003eThe Short Circuit Current Rating (SCCR) is 100 kA, providing robust protection in high-fault-current environments.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337896731,"sku":"LC1D09E7","price":27.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09e7-5hp-power-contactor_15c82e70-1edf-4747-8f28-e659e45ef2b1.jpg?v=1777165570"},{"product_id":"schneider-electric-lc1d09ed-contactor","title":"Schneider Electric LC1D09ED TeSys Deca Contactor 3P 3NO AC-3 9 A 48 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09ED is a 3-pole TeSys Deca contactor rated 9 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 4 kW at 400 V. It carries a 48 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03389110353174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3 it covers motors up to 4 kW at 400 V; The 48 V DC coil suits battery-backed or DC control circuits commonly found in rail and marine panels. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230337962267,"sku":"LC1D09ED","price":32.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09ed-contactor.jpg?v=1790900942"},{"product_id":"schneider-lc1d09f7-tesys-deca-9a-3p-480v-contactor","title":"Schneider Electric LC1D09F7 TeSys Deca 3-Pole 9A 480V AC 5HP 100kA SCCR Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09F7 is a TeSys Deca series 3-pole AC contactor rated at 9A and 480V AC, designed for reliable motor switching and control in industrial applications. With a 5HP power rating and an impressive 100kA SCCR (Short Circuit Current Rating), this contactor delivers robust protection and performance for motor starter circuits, HVAC systems, and automation panels. The LC1D series is one of the most widely used contactor families in industrial electrical installations worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.368 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230338060571,"sku":"LC1D09F7","price":27.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09f7-100ka-sccr-contactor_5b16c036-5732-42b1-bba6-e94c37338bc9.jpg?v=1777165575"},{"product_id":"schneider-electric-lc1d09fd-contactor","title":"Schneider Electric LC1D09FD TeSys Deca Contactor 3P 3NO AC-3 9 A 110 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09FD is a 3-pole TeSys Deca contactor rated 9 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 4 kW at 400 V. It carries a 110 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110353181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3 it covers motors up to 4 kW at 400 V; The 110 V DC coil matches substation and switchgear control-circuit standards that run DC at this level. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230338158875,"sku":"LC1D09FD","price":32.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09fd-contactor.jpg?v=1790900951"},{"product_id":"schneider-electric-lc1d09kue-contactor","title":"Schneider Electric LC1D09KUE TeSys Deca Contactor 3P 3NO AC-3 9 A 100-250 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09KUE is a 3-pole TeSys Deca contactor rated 9 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 4 kW at 400 V. It carries a 100-250 V AC\/DC electronic coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09KUE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480987656\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...250 V AC 50\/60 Hz \/ 100...250 V DC (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.368 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 100-250 V AC\/DC electronic coil accepts both AC and DC supply over its full voltage band, so the same reference covers 100-250 V control circuits without a separate AC or DC part number, and its low hold-in consumption reduces heat inside the enclosure versus a conventional coil. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety circuits without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230338322715,"sku":"LC1D09KUE","price":47.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09kue-contactor.jpg?v=1790900959"},{"product_id":"schneider-lc1d09m7-tesys-deca-9a-3p-480v-contactor","title":"Schneider Electric LC1D09M7 TeSys Deca 9A 3-Pole 480V AC Coil 5HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09M7 is a TeSys Deca series 3-pole power contactor rated at 9A with a 480V AC coil, designed for reliable motor switching and control in industrial applications. With a breaking capacity of 100 kA and a 5HP power rating, the LC1D09M7 delivers robust performance in demanding environments. Weighing just 0.32 kg, this compact contactor is engineered for panel builders and OEMs requiring dependable AC motor starter solutions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for switching and controlling AC induction motors up to 5HP in industrial machinery and HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Panels:\u003c\/strong\u003e Commonly used with thermal overload relays to form a complete motor starter assembly in MCC panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps \u0026amp; Compressors:\u003c\/strong\u003e Suitable for controlling pump and compressor motors in process industries requiring reliable switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Used in conveyor and material handling applications where frequent motor starting and stopping is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Equipment:\u003c\/strong\u003e Preferred by OEM machine builders for its compact footprint and high breaking capacity in automated production lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230338421019,"sku":"LC1D09M7","price":27.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09m7-5hp-power-contactor_194033c5-9636-4d6f-a2af-9f06ba69fa96.jpg?v=1777165579"},{"product_id":"schneider-lc1d09q7-tesys-deca-9a-3p-480v-contactor","title":"Schneider Electric LC1D09Q7 TeSys Deca 9A 3-Pole 480V AC Coil 5HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09Q7 is a TeSys Deca series 3-pole power contactor rated at 9A with a 480V AC coil, designed for reliable motor switching and control in industrial applications. Built for AC-3 utilization category, this contactor delivers a 100 kA breaking capacity and supports up to 5HP motor loads, making it an ideal solution for motor starter panels, machine control, and automation systems. The LC1D series is widely recognized for its compact footprint and robust performance across demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09Q7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line starting of 3-phase AC motors up to 5HP in industrial machinery and HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Panels:\u003c\/strong\u003e Suited for PLC-controlled switchgear panels requiring reliable 9A load switching with a compact contactor footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Used in OEM machine control cabinets where TeSys Deca contactors are a standard building block for motor starter circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Excellent for repetitive switching of pump and fan motors in building services and process industries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230338748699,"sku":"LC1D09Q7","price":27.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09q7-5hp-power-contactor_4cb1cf6c-e39d-43f9-97fe-0f8182fd6b4e.jpg?v=1777165583"},{"product_id":"schneider-electric-lc1d09v7-contactor","title":"Schneider Electric LC1D09V7 TeSys Deca Contactor 3P 3NO AC-3 9 A 400 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D09V7 is a 3-pole TeSys Deca contactor rated 9 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 4 kW at 400 V. It carries a 400 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D09V7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3 it covers motors up to 4 kW at 400 V; The 400 V AC coil connects straight to the incoming three-phase supply, removing the need for a separate control transformer. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230339109147,"sku":"LC1D09V7","price":22.22,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d09v7-contactor.jpg?v=1790900967"},{"product_id":"schneider-lc1d115bd-tesys-deca-115a-3p-contactor","title":"Schneider Electric LC1D115BD TeSys Deca 3-Pole 115A 75HP 480V AC 24VDC Coil Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D115BD is a TeSys Deca series 3-pole power contactor rated at 115A and 75HP for 480V AC motor control applications. Designed for demanding industrial environments, the LC1D115BD operates on a 24VDC coil and delivers a breaking capacity of 100 kA, making it a reliable solution for heavy-duty motor switching, load control, and distribution panel integration. With a compact yet robust construction weighing 2.5 kg, this contactor suits high-power motor starter assemblies across manufacturing, HVAC, and process industries.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D115BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating (HP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Direct-on-line starting and stopping of 3-phase AC motors up to 75HP at 480V AC in AC-3 utilization category.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Switching large fan motors, compressors, and pump drives in commercial and industrial HVAC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing \u0026amp; Process:\u003c\/strong\u003e Integration into motor control centers (MCCs) for conveyors, mixers, and heavy machine drives requiring reliable high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Used as a main switching element within control panels where 24VDC control circuits are standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Compatible with PLC-driven control architectures using 24VDC output modules for direct coil actuation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat coil voltage does the LC1D115BD use?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D115BD is fitted with a 24V DC coil, making it directly compatible with standard PLC output cards and 24VDC control panels.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the maximum motor rating for this contactor?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eAt 480V AC, the LC1D115BD is rated for motors up to 75 HP, suitable for heavy-duty 3-phase induction motor applications.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan auxiliary contact blocks be added to the LC1D115BD?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes, the TeSys Deca platform supports front- and side-mount auxiliary contact blocks for signalling and interlocking functions.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat utilization category does this contactor cover?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D115BD is designed for AC-3 (squirrel-cage motor starting) and AC-1 (non-inductive or slightly inductive loads) applications.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230340976923,"sku":"LC1D115BD","price":424.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d115bd-coil-power-contactor_1c1de1d9-a3fd-42c3-9381-e8d5bb599621.jpg?v=1777165587"},{"product_id":"schneider-lc1d115f7-tesys-deca-115a-3p-contactor","title":"Schneider Electric LC1D115F7 TeSys Deca 3-Pole 115A 75HP 480V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D115F7 is a TeSys Deca series 3-pole AC contactor rated at 115A and 75HP at 480V AC, engineered for robust motor control and industrial power switching applications. With a short-circuit current rating (SCCR) of 100kA, the LC1D115F7 delivers exceptional fault protection in demanding electrical installations. Weighing 2.5kg, this contactor offers a compact yet powerful solution for panel builders and OEMs requiring reliable motor starter contactors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D115F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing 3-phase AC motors up to 75HP in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Suitable for controlling large compressor and fan motors in commercial and industrial HVAC equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Conveyor Control:\u003c\/strong\u003e Reliable switching for pumping stations, conveyor drives, and material handling systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Building \u0026amp; OEM:\u003c\/strong\u003e Designed for integration into motor control centers (MCCs), switchboards, and custom control panels requiring high fault-withstand ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Compatible with PLC-driven control architectures where frequent switching cycles and long service life are required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the rated current of the LC1D115F7?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D115F7 is rated at 115A, suitable for motor loads up to 75HP at 480V AC.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the SCCR of this contactor?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe short-circuit current rating (SCCR) is 100kA, providing robust protection in high fault-current installations.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow many poles does the LC1D115F7 have?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is a 3-pole contactor, designed for three-phase AC motor and power switching applications.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhich series does this contactor belong to?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D115F7 is part of Schneider Electric's TeSys Deca series, known for high reliability and compact design.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230341763355,"sku":"LC1D115F7","price":342.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d115f7-480v-ac-contactor_4caafd96-e820-4156-ab1a-75cc0b6ffe9b.jpg?v=1777165591"},{"product_id":"schneider-lc1d115m7-tesys-deca-115a-3p-contactor","title":"Schneider Electric LC1D115M7 TeSys Deca 3P 115A 55kW AC-3 Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D115M7 is a TeSys Deca series 3-pole power contactor rated at 115 A (AC-3, ≤440 V, below 60 °C) with a 55 kW motor power rating at 380–400 V AC 50\/60 Hz, designed for demanding industrial motor switching and load control applications. Built to IEC 60947-4-1 and UL 508 standards, the LC1D115M7 delivers a breaking capacity of 1100 A at 440 V, making it a robust and reliable choice for engineers specifying high-current motor starter circuits. With a wide voltage tolerance up to 1000 V AC at 25–400 Hz, rail or plate mounting flexibility, and a comprehensive global certification portfolio, the LC1D115M7 suits a broad range of industrial environments worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D115M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 A at ≤ 440 V AC (below 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1000 V AC, 25–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW at 380–400 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 A at 440 V (IEC 60947 power circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158 mm × 120 mm × 136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4-1:\u003c\/strong\u003e European harmonized standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e European harmonized standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN\/ISO 13849-1:\u003c\/strong\u003e Safety of machinery — safety-related parts of control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment (UL listed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories general listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No 14:\u003c\/strong\u003e Industrial Control Equipment — Canadian standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — international safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOST:\u003c\/strong\u003e Russian\/CIS conformity certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVL \/ DNV \/ GL \/ RINA \/ ROS (Lloyd's Register of Shipping) \/ IACS E10:\u003c\/strong\u003e Marine and offshore approvals for shipboard electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP ratings)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-30:\u003c\/strong\u003e Environmental testing — damp heat cyclic test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60695-2-1:\u003c\/strong\u003e Fire hazard testing — glow-wire flammability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL94 V1:\u003c\/strong\u003e Flammability rating for plastic materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230342156571,"sku":"LC1D115M7","price":342.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d115m7-55kw-ac-3-contactor_deff9ed9-0b8b-447b-8ff0-3a59b90caa5e.jpg?v=1777165595"},{"product_id":"schneider-lc1d12b7-tesys-deca-12a-3p-contactor","title":"Schneider Electric LC1D12B7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12B7 is a TeSys Deca series 3-pole AC contactor rated at 12A and 480V AC, delivering reliable motor switching for loads up to 7.5HP. Designed for industrial motor control and power switching applications, the LC1D12B7 features a 100kA SCCR (Short-Circuit Current Rating), making it suitable for demanding electrical installations where high fault-current withstand capability is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12B7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.485 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Switching:\u003c\/strong\u003e Ideal for direct-on-line starting of 3-phase motors up to 7.5HP in HVAC, pump, and conveyor applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suited for PLC-controlled switching circuits requiring reliable, repetitive operation in manufacturing and process control environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Integrates seamlessly into MCC (Motor Control Center) designs and control panels requiring compact, high-performance contactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Fault-Current Installations:\u003c\/strong\u003e The 100kA SCCR rating makes LC1D12B7 appropriate for installations with high available fault current, ensuring system safety and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the coil voltage of the LC1D12B7?\u003c\/strong\u003e The suffix \"B7\" in the Schneider Electric LC1D naming convention designates a 24V AC coil voltage. Verify with your local Schneider Electric representative to confirm for your specific application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the LC1D12B7 be used with auxiliary contact blocks?\u003c\/strong\u003e Yes, the TeSys Deca LC1D series is compatible with a range of add-on auxiliary contact blocks for expanded control and signaling functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat utilization category does this contactor support?\u003c\/strong\u003e TeSys Deca contactors are designed for AC-3 (squirrel-cage motor starting) and AC-1 (non-inductive loads) utilization categories per IEC 60947-4-1.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346285339,"sku":"LC1D12B7","price":30.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12b7-ac-7-5hp-contactor_59e6993b-428d-44d4-8a58-8371b871f583.jpg?v=1777165600"},{"product_id":"schneider-lc1d12bd-tesys-deca-12a-3p-contactor","title":"Schneider Electric LC1D12BD TeSys Deca 3-Pole 12A 480V AC 7.5HP 24VDC Coil Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12BD is a TeSys Deca series 3-pole power contactor rated at 12A and 480V AC, delivering reliable motor switching for loads up to 7.5HP with a robust 100kA SCCR. Designed for demanding industrial motor control applications, the LC1D12BD operates on a 24VDC coil and offers compact, DIN-rail-compatible construction suited for panel builders and OEM machine builders alike.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current Rating (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.325 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Switching and controlling three-phase AC induction motors up to 7.5HP in industrial panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Reliable ON\/OFF switching for HVAC fans, water pumps, and cooling systems requiring 12A load management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Machine Tool Automation:\u003c\/strong\u003e Used in automated production lines where consistent 3-pole switching with high SCCR protection is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Compact TeSys Deca form factor fits tight panel layouts; the 24VDC coil integrates directly with PLC outputs without additional relays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversing Starter Combinations:\u003c\/strong\u003e Pairs with matching LC1D contactors and LRD overload relays to form complete IEC motor starter assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346350875,"sku":"LC1D12BD","price":45.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12bd-coil-power-contactor_211c4819-3db0-449b-89d7-d72dc70446f5.jpg?v=1777165604"},{"product_id":"schneider-electric-lc1d12bl-tesys-deca-contactor","title":"Schneider Electric LC1D12BL TeSys Deca LC1D 12 A 24 VDC 3-Pole Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12BL is a TeSys Deca IEC contactor with 3 poles (3 NO) rated 12 A AC-3, switching motors up to 5.5 kW at 380\/400 V. It runs on a low-consumption 24 V DC coil with a built-in transient suppressor and includes 1 NO + 1 NC mirror-certified auxiliary contacts, rated for up to 3600 operating cycles per hour at 60 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current [Ie] AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current [Ie] AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage [Uc]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW at 380\/400 V AC; 5.5 kW at 415\/440 V AC; 7.5 kW at 500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit up to 690 V AC \/ 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s; 105 A - 10 s (40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC, mirror contact certified (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.485 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C (with derating to 70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110361469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eEN 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12 A AC-3 this contactor covers motors up to 5.5 kW at 400 V and 7.5 kW at 690 V; a higher current variant in the same LC1D range is needed for larger motors. The low-consumption 24 V DC coil with its built-in transient suppressor draws only 2.4 W holding, which matters when many contactors share a single 24 V control supply. The built-in 1 NO + 1 NC auxiliary block is mirror-contact certified, meaning the NC contact can be used directly for safety-related positive-guided feedback (up to B10d = 1,369,863 cycles under nominal load per EN\/ISO 13849-1) without an add-on auxiliary contact block.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the switching element in direct-on-line and reversing motor starters, and for resistive load switching, in panels standardized on a 24 V DC control circuit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346481947,"sku":"LC1D12BL","price":31.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12bl-tesys-deca-contactor.jpg?v=1790283448"},{"product_id":"schneider-electric-lc1d12d7-contactor","title":"Schneider Electric LC1D12D7 TeSys Deca Contactor 3P 3NO AC-3 12 A 42 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12D7 is a 3-pole TeSys Deca contactor rated 12 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 5.5 kW at 400 V. It carries a 42 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12D7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.325 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12 A AC-3 it covers motors up to 5.5 kW at 400 V; The 42 V AC coil matches low-voltage control transformers used where reduced control-circuit voltage is a panel safety requirement. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346645787,"sku":"LC1D12D7","price":24.81,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12d7-contactor.jpg?v=1790900976"},{"product_id":"schneider-lc1d12e7-tesys-deca-12a-3p-contactor","title":"Schneider Electric LC1D12E7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Motor Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12E7 is a TeSys Deca series 3-pole AC contactor rated at 12A and 480V AC, designed for motor switching and control applications up to 7.5 HP. Built to IEC standards with a breaking capacity of 100 kA, the LC1D12E7 delivers reliable performance in industrial motor starter circuits, HVAC systems, and machine control panels. Weighing just 0.325 kg, this compact contactor suits DIN rail or panel-mount installations where space and dependability are critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12E7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.325 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC standards for industrial contactors and motor switching devices, ensuring global compliance and interoperability.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346744091,"sku":"LC1D12E7","price":30.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12e7-7-5hp-motor-contactor_40d49129-3c42-490b-831c-07da631e2bf6.jpg?v=1777165608"},{"product_id":"schneider-lc1d12f7-tesys-deca-12a-3p-480v-contactor","title":"Schneider Electric LC1D12F7 TeSys Deca 3-Pole 12A 480V AC Coil 7.5HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12F7 is a TeSys Deca series 3-pole power contactor rated at 12A with a 480V AC coil, designed for motor control and industrial power switching applications. With a 7.5HP motor rating and a short-circuit current rating (SCCR) of 100 kA, the LC1D12F7 delivers reliable performance in demanding industrial environments. Weighing just 0.485 kg, this compact contactor fits easily into control panels and motor control centers.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.485 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Switching and controlling three-phase induction motors up to 7.5HP in pump, fan, compressor, and conveyor applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Used in motor control centers (MCCs), machine tool panels, and automated manufacturing lines requiring reliable power switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Suitable for controlling HVAC fan and compressor motors in commercial and industrial buildings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e General-purpose load switching for resistive and inductive loads in industrial control panels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346809627,"sku":"LC1D12F7","price":30.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12f7-7-5hp-power-contactor_28c6091c-3fb5-4287-8346-c8203a5890f8.jpg?v=1777165613"},{"product_id":"schneider-electric-lc1d12fd-contactor","title":"Schneider Electric LC1D12FD TeSys Deca Contactor 3P 3NO AC-3 12 A 110 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12FD is a 3-pole TeSys Deca contactor rated 12 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 5.5 kW at 400 V. It carries a 110 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110353914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.485 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12 A AC-3 it covers motors up to 5.5 kW at 400 V; The 110 V DC coil matches substation and switchgear control-circuit standards that run DC at this level. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230346875163,"sku":"LC1D12FD","price":36.52,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12fd-contactor.jpg?v=1790900984"},{"product_id":"schneider-lc1d12m7-tesys-deca-12a-3p-480v-contactor","title":"Schneider Electric LC1D12M7 TeSys Deca 3-Pole 12A 480V AC 7.5HP 100kA SCCR Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12M7 is a TeSys Deca series 3-pole AC contactor rated at 12A and 480V AC, delivering 7.5HP motor switching capability with a 100kA SCCR for robust short-circuit protection. Engineered for industrial motor control applications, this contactor provides reliable performance in demanding environments where dependable load switching is critical. The LC1D12M7 is a compact, high-performance solution trusted by engineers and panel builders worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.325 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230347104539,"sku":"LC1D12M7","price":30.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12m7-100ka-sccr-contactor_9fd7e68a-6a0f-4db7-9c2e-164b6318c701.jpg?v=1777165620"},{"product_id":"schneider-electric-lc1d12q7-contactor","title":"Schneider Electric LC1D12Q7 TeSys Deca Contactor 3P 3NO AC-3 12 A 380 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D12Q7 is a 3-pole TeSys Deca contactor rated 12 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 5.5 kW at 400 V. It carries a 380 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D12Q7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.325 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12 A AC-3 it covers motors up to 5.5 kW at 400 V; The 380 V AC coil matches 380 V three-phase control circuits common on older or imported panel designs. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230347399451,"sku":"LC1D12Q7","price":24.81,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d12q7-contactor.jpg?v=1790900993"},{"product_id":"schneider-lc1d150b7-tesys-deca-150a-3p-contactor","title":"Schneider Electric LC1D150B7 TeSys Deca 3-Pole 150A 480V AC 100HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D150B7 is a TeSys Deca series 3-pole power contactor rated at 150A and 480V AC, delivering up to 100HP of motor switching capability with a breaking capacity of 100 kA. Designed for demanding industrial motor control applications, the LC1D150B7 offers robust performance and reliable operation in AC-3 and AC-1 utilization categories. With a compact yet rugged construction and a weight of 2.5 kg, this contactor is engineered to meet the high expectations of electrical engineers and procurement professionals specifying equipment for motor starters, drives, and power distribution panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D150B7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230349005083,"sku":"LC1D150B7","price":394.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d150b7-100hp-power-contactor_bdf9e07a-cd9e-44d3-972d-96226753074c.jpg?v=1777165625"},{"product_id":"schneider-lc1d150bd-tesys-deca-150a-3p-contactor","title":"Schneider Electric LC1D150BD TeSys Deca 3-Pole 150A 480V AC 24V DC Coil Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D150BD is a TeSys Deca series 3-pole power contactor rated at 150A and 480V AC, designed for demanding motor control and power switching applications up to 100HP. With a 24V DC control coil and a robust 100 kA breaking capacity, the LC1D150BD delivers reliable performance in industrial automation, HVAC, pump, and compressor control panels. Weighing 2.5 kg, this contactor is engineered for switchboard and DIN-rail installations where space efficiency and operational durability are critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D150BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing large AC motors up to 100HP in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Suitable for controlling compressors, air handling units, and large fan motors in commercial and industrial HVAC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Control:\u003c\/strong\u003e Used in water treatment plants, oil \u0026amp; gas facilities, and process industries for reliable pump and compressor switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Integrates into MCC (Motor Control Centers) and switchboard assemblies requiring high-current switching capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Compatible with PLC-driven control architectures requiring a 24V DC coil signal for switching heavy loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230349103387,"sku":"LC1D150BD","price":496.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d150bd-coil-power-contactor_d3f38533-3f87-474a-914e-41ddd5527706.jpg?v=1777165630"},{"product_id":"schneider-lc1d150f7-tesys-deca-150a-3p-contactor","title":"Schneider Electric LC1D150F7 TeSys Deca 3-Pole 150A 480V AC 100HP 100kA SCCR Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D150F7 is a TeSys Deca series 3-pole power contactor rated at 150A and 480V AC, delivering 100HP motor control capability with a robust 100kA SCCR breaking capacity. Designed for demanding industrial motor switching and power distribution applications, this contactor carries cULus certification, making it fully compliant for use in North American installations. Built for reliability in AC-3 and AC-1 utilization categories, it is a trusted choice for engineers and procurement professionals specifying motor starter contactors.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D150F7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to Canadian and US safety standards (CSA and UL), confirming suitability for North American industrial and commercial electrical installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty AC motor starting and stopping in industrial plants and manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003eMotor control centers (MCCs) requiring a high-current 150A power contactor\u003c\/li\u003e\n  \u003cli\u003eHVAC systems, pumps, compressors, and conveyor drives rated up to 100HP at 480V AC\u003c\/li\u003e\n  \u003cli\u003ePanel builders and OEMs designing UL-listed motor starter assemblies for the North American market\u003c\/li\u003e\n  \u003cli\u003eApplications demanding high short-circuit current rating (100kA SCCR) for overcurrent coordination\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230349594907,"sku":"LC1D150F7","price":394.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d150f7-100ka-sccr-contactor_ec37a328-5484-424c-b08f-52a360126748.jpg?v=1777165635"},{"product_id":"schneider-lc1d150m7-tesys-deca-150a-3p-contactor","title":"Schneider Electric LC1D150M7 TeSys Deca 3-Pole 150A 480V AC 100HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D150M7 is a TeSys Deca series 3-pole power contactor rated at 150A and 480V AC, designed for controlling motors up to 100HP in industrial power distribution and motor control applications. Built for demanding environments, the LC1D150M7 delivers a breaking capacity of 100 kA and features an open-type mounting configuration suitable for panel builders and OEM integrators. The LC1D series is a trusted solution for AC-3 motor switching, offering reliable performance in variable-duty industrial cycles.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D150M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Ideal for switching and controlling three-phase induction motors up to 100HP in MCC assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Used in compressors, conveyors, pumps, and fans requiring reliable high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Builders \u0026amp; OEM Systems:\u003c\/strong\u003e Open mounting design makes the LC1D150M7 easy to integrate into custom control panels and switchgear assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Suitable for AC-3 utilization category applications where frequent starting and stopping of squirrel-cage motors is required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat utilization category is the LC1D150M7 rated for?\u003c\/strong\u003e The LC1D150M7 is designed for AC-3 utilization category, making it suitable for direct-on-line starting of squirrel-cage motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the breaking capacity of the LC1D150M7?\u003c\/strong\u003e It has a breaking capacity of 100 kA, ensuring robust short-circuit protection capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated motor power for this contactor?\u003c\/strong\u003e The LC1D150M7 is rated for 100HP (approximately 75 kW) motor loads at 480V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat mounting type does the LC1D150M7 use?\u003c\/strong\u003e It features an open mounting type, suitable for DIN rail or panel mounting configurations depending on the accessory used.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230349791515,"sku":"LC1D150M7","price":394.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d150m7-100hp-power-contactor_b2004746-4761-418a-a345-adff560733aa.jpg?v=1777165639"},{"product_id":"schneider-lc1d18b7-tesyns-d-18a-3p-contactor","title":"Schneider Electric LC1D18B7 TeSys D 3P 18A 7.5kW 24V AC Coil Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18B7 is a TeSys D series 3-pole power contactor rated at 18 A (AC-3) and 32 A (AC-1), designed for motor switching and control applications up to 7.5 kW at 380–400 V AC. With a 24 V AC coil and compatibility with DIN rail or plate mounting, the LC1D18B7 delivers reliable performance across a wide voltage range up to 690 V AC, making it an industry-standard choice for industrial motor starters and power control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18B7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Power Circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 380–400 V AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 415–440 V AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 500 V AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power @ 660–690 V AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail, Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4-1:\u003c\/strong\u003e European harmonized standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e European harmonized standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No 14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas marine approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGL:\u003c\/strong\u003e Germanischer Lloyd marine approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOST:\u003c\/strong\u003e Russian\/CIS certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLROS:\u003c\/strong\u003e Lloyd's Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN\/ISO 13849-1:\u003c\/strong\u003e Safety of machinery — safety-related parts of control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-30:\u003c\/strong\u003e Environmental testing — damp heat cyclic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60695-2-1:\u003c\/strong\u003e Fire hazard testing — glow-wire method\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 94:\u003c\/strong\u003e Flammability rating for plastic materials\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase AC motor switching and starting in industrial machinery\u003c\/li\u003e\n\u003cli\u003eMotor control centres (MCCs) and distribution boards\u003c\/li\u003eli\u0026gt;\u003cli\u003eHVAC systems — compressor and fan motor control\u003c\/li\u003e\n\u003cli\u003ePump and conveyor motor starters\u003c\/li\u003e\n\u003cli\u003eMarine and offshore electrical control panels (BV, DNV, GL, LROS, RINA approved)\u003c\/li\u003e\n\u003cli\u003eMachine safety circuits conforming to EN\/ISO 13849-1\u003c\/li\u003e\n\u003cli\u003eOEM control panels requiring compact DIN rail-mounted switching\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230354313499,"sku":"LC1D18B7","price":36.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18b7-coil-power-contactor_7e404c00-2d48-458a-8396-412c545165c9.jpg?v=1777165643"},{"product_id":"schneider-lc1d18bd-tesys-deca-18a-3p-contactor","title":"Schneider Electric LC1D18BD TeSys Deca 3-Pole 18A 24VDC Coil 10HP 480V AC Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18BD is a TeSys Deca series 3-pole power contactor rated at 18A with a 24V DC coil, designed for motor switching and control applications up to 10 HP at 480V AC. Built for industrial environments, this contactor delivers robust performance with a short-circuit current rating (SCCR) of 100 kA, making it a reliable choice for demanding motor starter and power switching duties.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting and stopping AC induction motors up to 10 HP in industrial machinery and HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in control panels and motor control centers (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Commonly paired with thermal overload relays to form a complete motor starter in AC-3 utilization category applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Compatible with PLCs and control systems using 24V DC coil signals for seamless integration into automated production lines.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the coil voltage of the LC1D18BD?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D18BD features a 24V DC coil, making it directly compatible with PLC outputs and low-voltage DC control circuits.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat utilization category does this contactor suit?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe TeSys Deca LC1D series is designed for AC-3 utilization category, which covers the starting and switching of squirrel-cage induction motors.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan auxiliary contacts be added to the LC1D18BD?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes, the TeSys Deca platform supports the addition of auxiliary contact blocks for expanded control and signaling functions.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the SCCR rating?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe LC1D18BD carries a Short-Circuit Current Rating (SCCR) of 100 kA, meeting requirements for high-fault-current industrial installations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230354510107,"sku":"LC1D18BD","price":55.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18bd-ac-power-contactor_d41b7df9-d31e-451a-aea9-5b8bd1ae4677.jpg?v=1777165647"},{"product_id":"schneider-lc1d18bl-lc1d-18a-480v-3pole-contactor","title":"Schneider Electric LC1D18BL LC1D 3-Pole 18A 480V AC 10HP TeSys Deca Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18BL is a TeSys Deca 3-pole AC contactor rated at 18A and 480V AC, delivering reliable motor switching and power control for industrial applications. Designed for demanding environments, this contactor handles up to 10HP at 480V AC and features a short-circuit current rating (SCCR) of 100 kA, making it a robust choice for motor starters and load switching panels. The LC1D18BL is part of the proven TeSys Deca series, widely trusted by engineers and panel builders worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Switching:\u003c\/strong\u003e Ideal for direct-on-line (DOL) motor starters controlling 3-phase induction motors up to 10HP at 480V AC in pumps, fans, conveyors, and compressors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Suitable for OEM panel builders assembling motor control centers (MCCs) and distribution boards requiring reliable, compact contactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversing Starters:\u003c\/strong\u003e Can be integrated into reversing starter configurations paired with a second LC1D series contactor and appropriate interlocking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistive \u0026amp; Heating Load Switching:\u003c\/strong\u003e Applicable for AC-1 utilization category loads including resistive heating elements and distribution loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Compatible with PLC outputs and relay logic for automated start\/stop sequences in manufacturing and process control environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230354837787,"sku":"LC1D18BL","price":48.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18bl-tesys-deca-contactor_52133d08-8eff-4aed-8848-69137d8e10ff.jpg?v=1777165652"},{"product_id":"schneider-electric-lc1d18d7-contactor","title":"Schneider Electric LC1D18D7 TeSys Deca Contactor 3P 3NO AC-3 18 A 42 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18D7 is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 42 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18D7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18 A AC-3 it covers motors up to 7.5 kW at 400 V; The 42 V AC coil matches low-voltage control transformers used where reduced control-circuit voltage is a panel safety requirement. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230355296539,"sku":"LC1D18D7","price":29.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18d7-contactor.jpg?v=1790900934"},{"product_id":"schneider-lc1d18e7-tesys-deca-18a-3p-480v-contactor","title":"Schneider Electric LC1D18E7 TeSys Deca 3-Pole 18A 480V AC 10HP Motor Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18E7 is a TeSys Deca series 3-pole AC contactor rated at 18A and 480V AC, delivering reliable motor switching for loads up to 10HP at 480V AC. Designed for demanding industrial motor control applications, the LC1D18E7 offers a robust 100kA SCCR (Short Circuit Current Rating), making it suitable for use in high-fault-current environments. Weighing just 0.49 kg, this compact contactor integrates seamlessly into motor control centres, panel boards, and machine control systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18E7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for switching and controlling three-phase AC motors up to 10HP in industrial and commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centres (MCC):\u003c\/strong\u003e Compact form factor suits DIN rail or panel-mount MCC configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Used in automated machinery requiring reliable, repetitive switching of inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Suitable for HVAC systems, pump stations, and ventilation fan control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Fault-Current Environments:\u003c\/strong\u003e 100kA SCCR rating ensures compliance in systems with high available fault current.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230355591451,"sku":"LC1D18E7","price":36.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18e7-10hp-motor-contactor_814fb7d7-4bd2-4694-b5aa-0d19cf9e3731.jpg?v=1777165656"},{"product_id":"schneider-electric-lc1d18ed-contactor","title":"Schneider Electric LC1D18ED TeSys Deca Contactor 3P 3NO AC-3 18 A 48 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18ED is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 48 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110354812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18 A AC-3 it covers motors up to 7.5 kW at 400 V; The 48 V DC coil suits battery-backed or DC control circuits commonly found in rail and marine panels. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230355951899,"sku":"LC1D18ED","price":44.61,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18ed-contactor.jpg?v=1790900942"},{"product_id":"schneider-lc1d18f7-tesys-deca-18a-3pole-contactor","title":"Schneider Electric LC1D18F7 TeSys Deca 3-Pole 18A 10HP 480V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18F7 is a TeSys Deca series 3-pole AC contactor rated at 18A with a 10HP motor load capacity at 480V AC, designed for reliable motor switching and industrial power control applications. With a 100kA SCCR short-circuit current rating, the LC1D18F7 delivers robust protection in demanding installations. Weighing just 0.378 kg, this compact contactor integrates seamlessly into motor control centers, control panels, and distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18F7\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.378 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Switching:\u003c\/strong\u003e Suitable for AC-3 duty motor control up to 10HP at 480V AC in industrial machinery and HVAC systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e The LC1D18F7 is a standard building block in MCC panels for factory automation and process control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Reliable switching for pump stations, ventilation fans, and compressor systems requiring frequent operation cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Used in industrial distribution boards where a compact, high-SCCR contactor is required for load switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Machine Builders:\u003c\/strong\u003e Lightweight and DIN-rail-compatible design makes the LC1D18F7 a preferred choice for OEM panel builders requiring proven Schneider Electric reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the rated current of the LC1D18F7?\u003c\/strong\u003e The LC1D18F7 is rated at 18A continuous current.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat motor horsepower can the LC1D18F7 handle?\u003c\/strong\u003e It is rated for 10HP at 480V AC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the SCCR of the LC1D18F7?\u003c\/strong\u003e The short-circuit current rating (SCCR) is 100 kA.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhich series does the LC1D18F7 belong to?\u003c\/strong\u003e It belongs to the Schneider Electric TeSys Deca series of contactors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow many poles does the LC1D18F7 have?\u003c\/strong\u003e It is a 3-pole contactor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230356246811,"sku":"LC1D18F7","price":36.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18f7-ac-coil-contactor.jpg?v=1777165660"},{"product_id":"schneider-electric-lc1d18fd-contactor","title":"Schneider Electric LC1D18FD TeSys Deca Contactor 3P 3NO AC-3 18 A 110 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18FD is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 110 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110354829\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18 A AC-3 it covers motors up to 7.5 kW at 400 V; The 110 V DC coil matches substation and switchgear control-circuit standards that run DC at this level. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230356771099,"sku":"LC1D18FD","price":44.61,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18fd-contactor.jpg?v=1790900952"},{"product_id":"schneider-electric-lc1d18kue-contactor","title":"Schneider Electric LC1D18KUE TeSys Deca Contactor 3P 3NO AC-3 18 A 100-250 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18KUE is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 100-250 V AC\/DC electronic coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18KUE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480987717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...250 V AC 50\/60 Hz \/ 100...250 V DC (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.378 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 100-250 V AC\/DC electronic coil accepts both AC and DC supply over its full voltage band, so the same reference covers 100-250 V control circuits without a separate AC or DC part number, and its low hold-in consumption reduces heat inside the enclosure versus a conventional coil. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety circuits without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230357360923,"sku":"LC1D18KUE","price":63.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18kue-contactor.jpg?v=1790901002"},{"product_id":"schneider-electric-lc1d18m7-tesys-deca-18a-3p-contactor","title":"Schneider Electric LC1D18M7 TeSys Deca 3-Pole 18A 10HP 480V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18M7 is a TeSys Deca series 3-pole AC contactor rated at 18A with a 10HP motor load capacity at 480V AC, designed for reliable motor switching and control applications in industrial environments. As a power contactor in the widely trusted TeSys Deca lineup, the LC1D18M7 delivers a 100kA SCCR (Short-Circuit Current Rating), making it suitable for demanding industrial power distribution panels. This contactor is an ideal solution for engineers and procurement professionals sourcing IEC-compliant motor starter contactor assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP at 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Compliant with International Electrotechnical Commission standards for industrial contactors and motor switching devices\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230357557531,"sku":"LC1D18M7","price":36.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18m7-480v-ac-contactor_4167ac62-b959-4000-a512-5247c7d71ec9.jpg?v=1777165665"},{"product_id":"schneider-electric-lc1d18q7-contactor","title":"Schneider Electric LC1D18Q7 TeSys Deca Contactor 3P 3NO AC-3 18 A 380 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18Q7 is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 380 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18Q7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18 A AC-3 it covers motors up to 7.5 kW at 400 V; The 380 V AC coil matches 380 V three-phase control circuits common on older or imported panel designs. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230359032091,"sku":"LC1D18Q7","price":29.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18q7-contactor.jpg?v=1790900960"},{"product_id":"schneider-electric-lc1d18v7-contactor","title":"Schneider Electric LC1D18V7 TeSys Deca Contactor 3P 3NO AC-3 18 A 400 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D18V7 is a 3-pole TeSys Deca contactor rated 18 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 7.5 kW at 400 V. It carries a 400 V AC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D18V7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110349603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003erail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77 x 45 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18 A AC-3 it covers motors up to 7.5 kW at 400 V; The 400 V AC coil connects straight to the incoming three-phase supply, removing the need for a separate control transformer. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230359589147,"sku":"LC1D18V7","price":29.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d18v7-contactor.jpg?v=1790900968"},{"product_id":"schneider-lc1d25b7-tesys-deca-25a-3p-480v-contactor","title":"Schneider Electric LC1D25B7 TeSys Deca 3-Pole 25A 480V AC 15HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25B7 is a TeSys Deca series 3-pole power contactor rated at 25A and 480V AC, designed for reliable motor switching and industrial automation applications. With a 15HP motor rating and 100kA breaking capacity, the LC1D25B7 delivers robust performance for AC-3 motor control in demanding environments. Weighing just 0.433 kg, this compact contactor is engineered for panel space efficiency without compromising switching reliability.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25B7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.433 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Stopping:\u003c\/strong\u003e Ideal for AC-3 duty — direct-on-line starting of squirrel-cage induction motors up to 15HP at 480V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for use in machine control panels, conveyor systems, pumps, fans, and compressors requiring reliable switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Compact 3-pole design integrates seamlessly into MCC assemblies and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Well-suited for controlling HVAC fans, blower motors, and compressor units in commercial and industrial buildings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industry:\u003c\/strong\u003e Applicable in manufacturing, water treatment, and material handling where frequent motor switching is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230366470427,"sku":"LC1D25B7","price":49.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25b7-15hp-power-contactor_62a859ca-fef2-42e4-954a-0fdb0aff216b.jpg?v=1777165669"},{"product_id":"schneider-lc1d25bd-tesys-deca-25a-3p-contactor","title":"Schneider Electric LC1D25BD TeSys Deca 3-Pole 25A 15HP 480V AC 24VDC Coil Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25BD is a TeSys Deca series 3-pole power contactor rated at 25A and 15HP at 480V AC, designed for reliable motor switching and industrial load control. Built with a 24VDC control coil and a 100kA SCCR, the LC1D25BD delivers robust short-circuit protection performance suitable for demanding industrial installations. Weighing just 0.53 kg, this compact contactor integrates seamlessly into motor control centers, panel boards, and automation panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 HP at 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current Rating (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing three-phase AC induction motors up to 15HP at 480V AC in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Designed for integration into modular MCC panels, switchgear lineups, and automation enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pump Systems:\u003c\/strong\u003e Commonly deployed in HVAC compressor control, chiller systems, and industrial pump motor switching applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Material Handling:\u003c\/strong\u003e Suitable for conveyor drives, hoists, and other cyclic duty motor applications requiring reliable switching endurance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Compatible with PLC-driven control circuits requiring a 24VDC coil signal for remote energization and de-energization.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230366732571,"sku":"LC1D25BD","price":73.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25bd-coil-power-contactor_17cab819-aba0-4e84-aad7-580f720eedb2.jpg?v=1777165673"},{"product_id":"schneider-electric-lc1d25bl-tesys-deca-contactor","title":"Schneider Electric LC1D25BL TeSys Deca LC1D 25 A 24 VDC 3-Pole Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25BL is a TeSys Deca IEC contactor with 3 poles (3 NO) rated 25 A AC-3, switching motors up to 11 kW at 380\/400 V. It runs on a low-consumption 24 V DC coil with a built-in transient suppressor and includes 1 NO + 1 NC mirror-certified auxiliary contacts, rated for up to 3600 operating cycles per hour at 60 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current [Ie] AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current [Ie] AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage [Uc]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW at 380\/400 V AC; 11 kW at 415\/440 V AC; 15 kW at 500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit up to 690 V AC \/ 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 A - 1 s; 240 A - 10 s (40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC, mirror contact certified (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 85 x 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C (with derating to 70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110361773\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eEN 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN 60947-5-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 A AC-3 this contactor covers motors up to 11 kW at 400 V and 15 kW at 690 V; a lower current variant in the same LC1D range fits smaller loads. The low-consumption 24 V DC coil with its built-in transient suppressor draws only 2.4 W holding, which matters when many contactors share a single 24 V control supply. The built-in 1 NO + 1 NC auxiliary block is mirror-contact certified, meaning the NC contact can be used directly for safety-related positive-guided feedback (up to B10d = 1,369,863 cycles under nominal load per EN\/ISO 13849-1) without an add-on auxiliary contact block.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the switching element in direct-on-line and reversing motor starters, and for resistive load switching, in panels standardized on a 24 V DC control circuit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230366994715,"sku":"LC1D25BL","price":51.59,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25bl-tesys-deca-contactor.jpg?v=1790283454"},{"product_id":"schneider-electric-lc1d25bne-contactor","title":"Schneider Electric LC1D25BNE TeSys Deca Contactor 3P 3NO AC-3 25 A 24-60 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25BNE is a 3-pole TeSys Deca contactor rated 25 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 11 kW at 400 V. It carries a 24-60 V AC\/DC electronic coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25BNE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480987724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24...60 V AC 50\/60 Hz \/ 24...60 V DC (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 92 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.433 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 24-60 V AC\/DC electronic coil accepts both AC and DC supply over its full voltage band, so the same reference covers 100-250 V control circuits without a separate AC or DC part number, and its low hold-in consumption reduces heat inside the enclosure versus a conventional coil. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety circuits without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230367355163,"sku":"LC1D25BNE","price":84.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25bne-contactor.jpg?v=1790901010"},{"product_id":"schneider-lc1d25e7-tesys-deca-25a-3p-480v-contactor","title":"Schneider Electric LC1D25E7 TeSys Deca 3-Pole 25A 480V AC Coil 15HP Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25E7 is a TeSys Deca series 3-pole power contactor rated at 25A with a 480V AC coil, designed for reliable motor switching and industrial power control applications. With a breaking capacity of 100 kA and a 15HP power rating, the LC1D25E7 delivers robust performance in demanding environments where dependable load switching is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25E7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Switching:\u003c\/strong\u003e Suited for AC-3 duty cycle applications including direct-on-line motor starters up to 15HP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Used in conveyor systems, pumps, compressors, fans, and HVAC equipment requiring reliable contactor switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCCs):\u003c\/strong\u003e Compatible with standard MCC configurations for centralized motor management in industrial plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Installed in control panels for switching resistive and inductive loads in manufacturing and process industries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230368043291,"sku":"LC1D25E7","price":49.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25e7-15hp-power-contactor_9abcee2b-d00c-4b12-96cc-89dbe83ec8c7.jpg?v=1777165677"},{"product_id":"schneider-electric-lc1d25ed-contactor","title":"Schneider Electric LC1D25ED TeSys Deca Contactor 3P 3NO AC-3 25 A 48 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25ED is a 3-pole TeSys Deca contactor rated 25 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 11 kW at 400 V. It carries a 48 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25ED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110356298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail; screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 A AC-3 it covers motors up to 11 kW at 400 V; The 48 V DC coil suits battery-backed or DC control circuits commonly found in rail and marine panels. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230368567579,"sku":"LC1D25ED","price":59.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25ed-contactor.jpg?v=1790900976"},{"product_id":"schneider-lc1d25f7-tesys-deca-25a-3p-contactor","title":"Schneider Electric LC1D25F7 TeSys Deca 3-Pole 25A 15HP 480V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25F7 is a TeSys Deca series 3-pole AC contactor rated at 25A and 15HP at 480V AC, designed for reliable motor switching and control in industrial applications. With a 100kA SCCR rating, the LC1D25F7 delivers robust short-circuit current protection suitable for demanding power distribution environments. Weighing just 0.37 kg, this compact contactor integrates seamlessly into motor control centers, panel boards, and machine control systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 HP at 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current Rating (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Switching and controlling three-phase AC motors in pumps, fans, compressors, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Plug-in or fixed mounting within MCC panels for centralized motor management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Used in OEM machinery where reliable, frequent switching of motor loads is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Controlling large fan and pump motors in commercial and industrial HVAC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Boards \u0026amp; Distribution:\u003c\/strong\u003e Integration into power distribution panels requiring high SCCR-rated switching devices.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230368796955,"sku":"LC1D25F7","price":49.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25f7-ac-coil-contactor_b5d82d69-dc74-4d10-9556-6a180bad290a.jpg?v=1777165682"},{"product_id":"schneider-electric-lc1d25fd-contactor","title":"Schneider Electric LC1D25FD TeSys Deca Contactor 3P 3NO AC-3 25 A 110 V DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25FD is a 3-pole TeSys Deca contactor rated 25 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 11 kW at 400 V. It carries a 110 V DC coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals on both power and control circuits for DIN-rail mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3389110356519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 A AC-3 it covers motors up to 11 kW at 400 V; The 110 V DC coil matches substation and switchgear control-circuit standards that run DC at this level. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230369091867,"sku":"LC1D25FD","price":59.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25fd-contactor.jpg?v=1790900985"},{"product_id":"schneider-electric-lc1d25kue-contactor","title":"Schneider Electric LC1D25KUE TeSys Deca Contactor 3P 3NO AC-3 25 A 100-250 V AC\/DC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25KUE is a 3-pole TeSys Deca contactor rated 25 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 11 kW at 400 V. It carries a 100-250 V AC\/DC electronic coil, a mechanically-linked 1 NO + 1 NC auxiliary contact with mirror-contact certification, and screw-clamp terminals for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25KUE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480987748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...250 V AC 50\/60 Hz \/ 100...250 V DC (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC (mirror contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 A - 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (front face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...60 °C \/ 60...70 °C (derated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 45 x 92 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.433 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 100-250 V AC\/DC electronic coil accepts both AC and DC supply over its full voltage band, so the same reference covers 100-250 V control circuits without a separate AC or DC part number, and its low hold-in consumption reduces heat inside the enclosure versus a conventional coil. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety circuits without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230370238747,"sku":"LC1D25KUE","price":82.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25kue-contactor.jpg?v=1790901018"},{"product_id":"schneider-lc1d25m7-tesys-deca-25a-3p-contactor","title":"Schneider Electric LC1D25M7 TeSys Deca 3-Pole 25A 15HP 480V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1D25M7 is a TeSys Deca series 3-pole AC contactor rated at 25A and 15HP at 480V AC, designed for reliable motor switching and industrial power control applications. With a short-circuit current rating (SCCR) of 100 kA, the LC1D25M7 delivers robust protection and performance in demanding electrical installations. Weighing just 0.37 kg, this compact contactor is engineered for panel space efficiency without compromising on switching capability.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D25M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 HP @ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (SCCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Switching:\u003c\/strong\u003e Ideal for AC-3 duty motor starters in industrial machinery, pumps, compressors, and conveyor systems up to 15HP at 480V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Board Integration:\u003c\/strong\u003e Compact form factor suits MCC (motor control center) panels and distribution boards where space is at a premium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for use in automated production lines, HVAC systems, and process control applications requiring reliable high-cycle switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e The 100 kA SCCR rating makes the LC1D25M7 appropriate for high-fault-current environments, ensuring system-level protection compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated motor horsepower for the LC1D25M7?\u003c\/strong\u003e The LC1D25M7 is rated for 15HP at 480V AC three-phase motor loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the suffix M7 indicate?\u003c\/strong\u003e The M7 suffix typically denotes the coil voltage variant. Consult the Schneider Electric TeSys Deca coil voltage table for the specific voltage this suffix represents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the LC1D25M7 part of the TeSys Deca series?\u003c\/strong\u003e Yes, the LC1D25M7 belongs to the Schneider Electric TeSys Deca contactor series, known for enhanced durability and optimized energy consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the SCCR of this contactor?\u003c\/strong\u003e The LC1D25M7 has a Short-Circuit Current Rating (SCCR) of 100 kA, suitable for high-fault-current industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230370533659,"sku":"LC1D25M7","price":49.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1d25m7-480v-ac-contactor_49db16ff-61df-4728-abce-b2fa255f618a.jpg?v=1777165686"}],"url":"https:\/\/stoklink.com\/collections\/schneider-tesys-deca.oembed?page=7","provider":"Stoklink","version":"1.0","type":"link"}