{"title":"Schneider GoPact MCCBs","description":"\u003cp\u003eSchneider Electric GoPact MCCBs are molded case circuit breakers for 16 A to 800 A distribution circuits. The range covers 3-pole and 4-pole breakers in several frame sizes, with 120 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGoPact MCCB 125, 200 and 400 frames.\u003c\/li\u003e\n\u003cli\u003eTM-D adjustable thermal-magnetic trip units.\u003c\/li\u003e\n\u003cli\u003eB and F breaking capacity classes.\u003c\/li\u003e\n\u003cli\u003eRelated ranges: \u003ca href=\"\/collections\/schneider-easypact-cvs\"\u003eSchneider EasyPact CVS MCCBs\u003c\/a\u003e and \u003ca href=\"\/collections\/schneider-compact-nsx\"\u003eSchneider ComPacT NSX MCCBs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFrame size and rated current must cover the load.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity class must exceed the fault level.\u003c\/li\u003e\n\u003cli\u003eAdjustable TM-D units allow fine setting of thermal and magnetic thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does the number in GoPact MCCB 125 mean?\u003c\/h3\u003e\u003cp\u003eIt is the frame size in amperes, the maximum rating the frame carries.\u003c\/p\u003e\u003ch3\u003eDoes GoPact come with electronic trip units?\u003c\/h3\u003e\u003cp\u003eThis range lists TM-D thermal-magnetic units. For electronic trip units see ComPacT NSX.\u003c\/p\u003e\u003ch3\u003eCan you export GoPact breakers?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-g12f3a100-gopact-mccb-125","title":"Schneider Electric G12F3A100 GoPact MCCB 125 3P 100 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A100 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 100 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1000 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (80-100 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1000 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (80-100 A)) lets this 100 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465481499,"sku":"G12F3A100","price":69.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a100-gopact-mccb-125.jpg?v=1790868106"},{"product_id":"schneider-electric-g12f3a125-gopact-mccb-125","title":"Schneider Electric G12F3A125 GoPact MCCB 125 3P 125 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A125 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 125 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1250 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (100-125 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1250 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (100-125 A)) lets this 125 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465547035,"sku":"G12F3A125","price":85.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a125-gopact-mccb-125.jpg?v=1790868115"},{"product_id":"schneider-electric-g12f3a16-gopact-mccb-125","title":"Schneider Electric G12F3A16 GoPact MCCB 125 3P 16 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A16 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 16 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (12.8-16 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (12.8-16 A)) lets this 16 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465612571,"sku":"G12F3A16","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a16-gopact-mccb-125.jpg?v=1790868126"},{"product_id":"schneider-electric-g12f3a20-gopact-mccb-125","title":"Schneider Electric G12F3A20 GoPact MCCB 125 3P 20 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A20 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 20 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (16-20 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (16-20 A)) lets this 20 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465678107,"sku":"G12F3A20","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a20-gopact-mccb-125.jpg?v=1790868135"},{"product_id":"schneider-electric-g12f3a25-gopact-mccb-125","title":"Schneider Electric G12F3A25 GoPact MCCB 125 3P 25 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A25 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 25 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (20-25 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (20-25 A)) lets this 25 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465743643,"sku":"G12F3A25","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a25-gopact-mccb-125.jpg?v=1790868158"},{"product_id":"schneider-electric-g12f3a32-gopact-mccb-125","title":"Schneider Electric G12F3A32 GoPact MCCB 125 3P 32 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A32 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 32 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (320 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (25.6-32 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (320 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (25.6-32 A)) lets this 32 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465809179,"sku":"G12F3A32","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a32-gopact-mccb-125.jpg?v=1790868170"},{"product_id":"schneider-electric-g12f3a40-gopact-mccb-125","title":"Schneider Electric G12F3A40 GoPact MCCB 125 3P 40 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A40 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 40 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (400 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (32-40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (400 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (32-40 A)) lets this 40 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465874715,"sku":"G12F3A40","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a40-gopact-mccb-125.jpg?v=1790868179"},{"product_id":"schneider-electric-g12f3a50-gopact-mccb-125","title":"Schneider Electric G12F3A50 GoPact MCCB 125 3P 50 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A50 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 50 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (500 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (40-50 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (40-50 A)) lets this 50 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229465973019,"sku":"G12F3A50","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a50-gopact-mccb-125.jpg?v=1790868190"},{"product_id":"schneider-electric-g12f3a63-gopact-mccb-125","title":"Schneider Electric G12F3A63 GoPact MCCB 125 3P 63 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A63 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 63 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (630 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (50.4-63 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (630 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (50.4-63 A)) lets this 63 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466202395,"sku":"G12F3A63","price":65.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a63-gopact-mccb-125.jpg?v=1790868199"},{"product_id":"schneider-electric-g12f3a80-gopact-mccb-125","title":"Schneider Electric G12F3A80 GoPact MCCB 125 3P 80 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3A80 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 80 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (800 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3A80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (64-80 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (800 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (64-80 A)) lets this 80 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466399003,"sku":"G12F3A80","price":69.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3a80-gopact-mccb-125.jpg?v=1790868215"},{"product_id":"schneider-g12f3f100-gopact-mccb-125-3p-100a-30ka","title":"Schneider Electric G12F3F100 GoPact MCCB 125 3P 100A 30kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F100 GoPact MCCB 125 is a 3-pole 100A molded case circuit breaker delivering 30 kA breaking capacity at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial control panels and distribution boards. Part of the GoPact MCCB 125 series, the G12F3F100 combines compact dimensions with robust thermal-magnetic trip technology, making it a dependable choice for motor branch circuits and feeder protection in commercial and industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Distribution Panels:\u003c\/strong\u003e Provides upstream feeder and branch circuit protection in low-voltage switchgear and distribution boards operating at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Branch Circuit Protection:\u003c\/strong\u003e Suitable for protecting motor feeders and branch circuits in manufacturing plants, pumping stations, and HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Building Services:\u003c\/strong\u003e Ideal for protecting sub-distribution circuits in commercial electrical installations requiring compact, high-breaking-capacity MCCBs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact form factor facilitates easy DIN rail or busbar mounting within automation and motor control centres (MCCs).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466595611,"sku":"G12F3F100","price":77.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f100-case-circuit-breaker_0411425c-da73-488a-a35b-f7bb4e4fbf40.jpg?v=1777165131"},{"product_id":"schneider-g12f3f125-gopact-mccb-125a-3p-30ka","title":"Schneider Electric G12F3F125 GoPact MCCB 125 3P 125A 30kA 415V Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F125 GoPact MCCB 125 is a 3-pole moulded case circuit breaker rated at 125A with a breaking capacity of 30 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution panels and control systems. Engineered for demanding environments, the GoPact MCCB 125 series delivers consistent performance in commercial and industrial installations where robust protection and compact design are essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Suitable for protecting outgoing feeders and branch circuits in industrial switchboards and distribution panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Provides short-circuit and overload protection for motor branch circuits in manufacturing and process automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Ideal for main and sub-distribution boards in commercial buildings, warehouses, and data centres requiring reliable 125A protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Fits neatly into DIN-rail or fixed-mount control panel assemblies where space efficiency is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery \u0026amp; OEM Equipment:\u003c\/strong\u003e Used by OEMs integrating overcurrent protection into machine control cabinets operating on 415V AC three-phase networks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466857755,"sku":"G12F3F125","price":86.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f125-case-circuit-breaker_b13b83ce-3cc7-4187-8e8d-aad5a3f9d5b9.jpg?v=1777165135"},{"product_id":"schneider-electric-g12f3f16-gopact-mccb-125","title":"Schneider Electric G12F3F16 GoPact MCCB 125 3P 16 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F16 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 16 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (16 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (16 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 16 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466923291,"sku":"G12F3F16","price":52.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f16-gopact-mccb-125.jpg?v=1790868227"},{"product_id":"schneider-electric-g12f3f20-gopact-mccb-125","title":"Schneider Electric G12F3F20 GoPact MCCB 125 3P 20 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F20 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 20 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (20 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (20 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 20 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229466988827,"sku":"G12F3F20","price":52.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f20-gopact-mccb-125.jpg?v=1790868236"},{"product_id":"schneider-g12f3f25-gopact-mccb-3p-25a-30ka","title":"Schneider Electric G12F3F25 GoPact MCCB 3P 25A 30kA Fixed Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F25 GoPact MCCB is a 3-pole, 25A fixed molded case circuit breaker engineered for reliable overcurrent and short-circuit protection in industrial power distribution panels. Delivering a breaking capacity of 30 kA at 380\/400\/415V AC, the G12F3F25 provides robust fault interruption performance suited to demanding commercial and industrial installations. Weighing just 0.7 kg, its compact form factor makes it an efficient choice for space-constrained control panels and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA @ 380\/400\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Distribution Boards:\u003c\/strong\u003e Provides short-circuit and overload protection for outgoing circuits in factory and plant distribution panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Suitable for protecting feeder and branch circuits in commercial electrical infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Compact fixed design integrates readily into motor control centers and automation control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Protection:\u003c\/strong\u003e Protects machinery and equipment circuits against overcurrent faults in manufacturing environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467087131,"sku":"G12F3F25","price":61.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f25-case-circuit-breaker_d8bd0a00-5669-407e-89f7-5c3b0e063427.jpg?v=1777165139"},{"product_id":"schneider-g12f3f32-gopact-mccb-125-3p-32a-30ka","title":"Schneider Electric G12F3F32 GoPact MCCB 125 3P 32A 30kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F32 GoPact MCCB 125 is a 3-pole 32A molded case circuit breaker delivering 30 kA breaking capacity at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial control panels and power distribution systems. Part of the GoPact MCCB 125 series, this compact and robust MCCB is designed to meet the demanding requirements of industrial automation environments. Weighing just 0.7 kg, it offers a space-efficient solution without compromising on performance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides reliable overcurrent and short-circuit protection in motor control centers and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Suited for protecting outgoing feeders in commercial and industrial low-voltage power distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Ideal for integration into industrial automation infrastructure where dependable circuit protection is essential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Building:\u003c\/strong\u003e Compact 3-pole design simplifies installation in DIN rail or fixed-mount panel configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467152667,"sku":"G12F3F32","price":61.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f32-case-circuit-breaker_c9bc2131-c28c-436e-b386-f97d88a779d4.jpg?v=1777165143"},{"product_id":"schneider-g12f3f40-gopact-mccb-3p-40a-30ka","title":"Schneider Electric G12F3F40 GoPact MCCB 3P 40A 30kA Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F40 is a GoPact series 3-pole molded case circuit breaker (MCCB) rated at 40A with a 30 kA breaking capacity, engineered for reliable overcurrent and short-circuit protection in industrial control panels, motor branch circuits, and distribution boards. Combining a compact footprint with robust interrupting performance, the G12F3F40 delivers dependable protection for demanding industrial and commercial electrical installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides overcurrent and short-circuit protection for motor feeders and branch circuits in automation and control panel assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistribution Boards:\u003c\/strong\u003e Suitable as a main or branch protective device in low-voltage distribution boards within commercial and industrial facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Branch Circuit Protection:\u003c\/strong\u003e Protects motors and associated loads against overload and fault currents, helping maintain system uptime and equipment integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Services \u0026amp; Infrastructure:\u003c\/strong\u003e Applicable in HVAC, pumping systems, and general building electrical infrastructure requiring reliable 3-phase protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467218203,"sku":"G12F3F40","price":61.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f40-case-circuit-breaker_d55dad61-d465-4fef-8177-d872bc2efe3a.jpg?v=1777165148"},{"product_id":"schneider-g12f3f50-gopact-mccb-3p-50a-30ka","title":"Schneider Electric G12F3F50 GoPact MCCB 3P 50A 30kA Fixed Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F50 GoPact MCCB is a 3-pole, 50A fixed molded case circuit breaker delivering a breaking capacity of 30kA — engineered for robust overload and short-circuit protection in industrial power distribution and control panel applications. Weighing just 0.7 kg, this compact yet high-performance MCCB from Schneider Electric's GoPact series is designed to meet the demanding requirements of modern industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides reliable overcurrent and short-circuit protection for motor control centers and industrial switchboards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Boards:\u003c\/strong\u003e Suitable for protecting distribution circuits in commercial and industrial facilities requiring up to 50A rated current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Ideal for integration into automation and process control panel assemblies where compact, high-capacity protection is essential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Used by OEMs and panel builders as a main or branch circuit protective device in machinery and equipment applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467283739,"sku":"G12F3F50","price":61.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f50-case-circuit-breaker_22ac84ee-132e-4b1f-8299-a9f4102cd6a6.jpg?v=1777165152"},{"product_id":"schneider-electric-g12f3f63-gopact-mccb-125","title":"Schneider Electric G12F3F63 GoPact MCCB 125 3P 63 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F63 is a 3-pole GoPact MCCB 125 moulded case circuit breaker rated 63 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (630 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (63 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (630 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (63 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 63 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467447579,"sku":"G12F3F63","price":52.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f63-gopact-mccb-125.jpg?v=1790869908"},{"product_id":"schneider-g12f3f80-gopact-mccb-3p-80a-30ka","title":"Schneider Electric G12F3F80 GoPact MCCB 3P 80A 30kA Fixed Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F3F80 is a GoPact series 3-pole molded case circuit breaker (MCCB) rated at 80A with a breaking capacity of 30 kA, designed for reliable overload and short-circuit protection in industrial and commercial power distribution systems. The fixed mounting configuration makes the G12F3F80 well-suited for integration into control panels and switchboards where a compact, high-performance MCCB is required. Weighing just 0.7 kg, this Schneider Electric GoPact MCCB offers an excellent combination of robust protection and space-efficient design.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F3F80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides dependable overcurrent and short-circuit protection in machine control and automation enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Power Distribution:\u003c\/strong\u003e Suitable for switchboards and distribution boards in commercial buildings requiring 80A branch protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Acts as a branch circuit protective device upstream of motor starters and drives in industrial automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrastructure \u0026amp; Utilities:\u003c\/strong\u003e Ideal for feeder and sub-feeder circuits in manufacturing plants, data centres, and utility installations where a 30 kA breaking rating is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467513115,"sku":"G12F3F80","price":77.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f3f80-case-circuit-breaker_3f14caf7-9bfb-43b5-872e-2ecec449bb59.jpg?v=1777165156"},{"product_id":"schneider-electric-g12f4a100-gopact-mccb-125","title":"Schneider Electric G12F4A100 GoPact MCCB 125 4P 100 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A100 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 100 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1000 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (80-100 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1000 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (80-100 A)) lets this 100 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467578651,"sku":"G12F4A100","price":89.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a100-gopact-mccb-125.jpg?v=1790868263"},{"product_id":"schneider-electric-g12f4a125-gopact-mccb-125","title":"Schneider Electric G12F4A125 GoPact MCCB 125 4P 125 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A125 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 125 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1250 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (100-125 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1250 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (100-125 A)) lets this 125 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467644187,"sku":"G12F4A125","price":116.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a125-gopact-mccb-125.jpg?v=1790868275"},{"product_id":"schneider-electric-g12f4a16-gopact-mccb-125","title":"Schneider Electric G12F4A16 GoPact MCCB 125 4P 16 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A16 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 16 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (12.8-16 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (12.8-16 A)) lets this 16 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467709723,"sku":"G12F4A16","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a16-gopact-mccb-125.jpg?v=1790868284"},{"product_id":"schneider-electric-g12f4a20-gopact-mccb-125","title":"Schneider Electric G12F4A20 GoPact MCCB 125 4P 20 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A20 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 20 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (16-20 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (16-20 A)) lets this 20 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467775259,"sku":"G12F4A20","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a20-gopact-mccb-125.jpg?v=1790868293"},{"product_id":"schneider-electric-g12f4a25-gopact-mccb-125","title":"Schneider Electric G12F4A25 GoPact MCCB 125 4P 25 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A25 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 25 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (20-25 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (20-25 A)) lets this 25 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467873563,"sku":"G12F4A25","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a25-gopact-mccb-125.jpg?v=1790868306"},{"product_id":"schneider-electric-g12f4a32-gopact-mccb-125","title":"Schneider Electric G12F4A32 GoPact MCCB 125 4P 32 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A32 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 32 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (320 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (25.6-32 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (320 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (25.6-32 A)) lets this 32 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229467939099,"sku":"G12F4A32","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a32-gopact-mccb-125.jpg?v=1790868315"},{"product_id":"schneider-electric-g12f4a40-gopact-mccb-125","title":"Schneider Electric G12F4A40 GoPact MCCB 125 4P 40 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A40 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 40 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (400 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (32-40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (400 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (32-40 A)) lets this 40 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468037403,"sku":"G12F4A40","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a40-gopact-mccb-125.jpg?v=1790868107"},{"product_id":"schneider-electric-g12f4a50-gopact-mccb-125","title":"Schneider Electric G12F4A50 GoPact MCCB 125 4P 50 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A50 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 50 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (500 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (40-50 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (40-50 A)) lets this 50 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468102939,"sku":"G12F4A50","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a50-gopact-mccb-125.jpg?v=1790868116"},{"product_id":"schneider-electric-g12f4a63-gopact-mccb-125","title":"Schneider Electric G12F4A63 GoPact MCCB 125 4P 63 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A63 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 63 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (630 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (50.4-63 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (630 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (50.4-63 A)) lets this 63 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468168475,"sku":"G12F4A63","price":84.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a63-gopact-mccb-125.jpg?v=1790868125"},{"product_id":"schneider-electric-g12f4a80-gopact-mccb-125","title":"Schneider Electric G12F4A80 GoPact MCCB 125 4P 80 A 30 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4A80 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 80 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (800 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4A80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.8 x In to 1 x In (64-80 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (800 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.8 x In to 1 x In (64-80 A)) lets this 80 A breaker be tuned down for loads sized below the nominal 125 A frame rating instead of locking in a single setting like the fixed-thermal (F) version at the same current. Choose the adjustable model when the actual load current is not fixed at design time; choose the fixed-thermal variant when the setting should never be touched after commissioning. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468234011,"sku":"G12F4A80","price":89.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4a80-gopact-mccb-125.jpg?v=1790868134"},{"product_id":"schneider-electric-g12f4f100-gopact-mccb-125","title":"Schneider Electric G12F4F100 GoPact MCCB 125 4P 100 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F100 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 100 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1000 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (100 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1000 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (100 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 100 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468299547,"sku":"G12F4F100","price":83.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f100-gopact-mccb-125.jpg?v=1790868144"},{"product_id":"schneider-electric-g12f4f125-gopact-mccb-125","title":"Schneider Electric G12F4F125 GoPact MCCB 125 4P 125 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F125 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 125 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (1250 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (125 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (1250 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (125 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 125 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229468496155,"sku":"G12F4F125","price":96.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f125-gopact-mccb-125.jpg?v=1790868153"},{"product_id":"schneider-electric-g12f4f16-gopact-mccb-125","title":"Schneider Electric G12F4F16 GoPact MCCB 125 4P 16 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F16 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 16 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (16 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (16 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 16 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469020443,"sku":"G12F4F16","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f16-gopact-mccb-125.jpg?v=1790868172"},{"product_id":"schneider-electric-g12f4f20-gopact-mccb-125","title":"Schneider Electric G12F4F20 GoPact MCCB 125 4P 20 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F20 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 20 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (20 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (20 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 20 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469085979,"sku":"G12F4F20","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f20-gopact-mccb-125.jpg?v=1790868187"},{"product_id":"schneider-electric-g12f4f25-gopact-mccb-125","title":"Schneider Electric G12F4F25 GoPact MCCB 125 4P 25 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F25 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 25 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 320 A, fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (25 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (25 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 25 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469184283,"sku":"G12F4F25","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f25-gopact-mccb-125.jpg?v=1790868202"},{"product_id":"schneider-electric-g12f4f32-gopact-mccb-125","title":"Schneider Electric G12F4F32 GoPact MCCB 125 4P 32 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F32 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 32 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (320 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (32 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (320 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (32 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 32 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469249819,"sku":"G12F4F32","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f32-gopact-mccb-125.jpg?v=1790868215"},{"product_id":"schneider-electric-g12f4f40-gopact-mccb-125","title":"Schneider Electric G12F4F40 GoPact MCCB 125 4P 40 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F40 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 40 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (400 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (400 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (40 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 40 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469315355,"sku":"G12F4F40","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f40-gopact-mccb-125.jpg?v=1790868231"},{"product_id":"schneider-electric-g12f4f50-gopact-mccb-125","title":"Schneider Electric G12F4F50 GoPact MCCB 125 4P 50 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F50 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 50 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (500 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (50 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (50 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 50 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469413659,"sku":"G12F4F50","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f50-gopact-mccb-125.jpg?v=1790868244"},{"product_id":"schneider-electric-g12f4f63-gopact-mccb-125","title":"Schneider Electric G12F4F63 GoPact MCCB 125 4P 63 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F63 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 63 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (630 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (63 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (630 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (63 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 63 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469511963,"sku":"G12F4F63","price":73.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f63-gopact-mccb-125.jpg?v=1790868263"},{"product_id":"schneider-electric-g12f4f80-gopact-mccb-125","title":"Schneider Electric G12F4F80 GoPact MCCB 125 4P 80 A 30 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G12F4F80 is a 4-pole GoPact MCCB 125 moulded case circuit breaker rated 80 A, built on the 125 A frame with an ultimate breaking capacity (Icu) of 30 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives fixed long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 10 x In (800 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG12F4F80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 30 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 380\/415 V AC, 50 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA at 380\/415 V AC, 25 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 1 x In (80 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 10 x In (800 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed-thermal (F) setting locks Ir at 1 x In (80 A), removing the adjustment dial so the trip point cannot drift after commissioning — the trade-off against the adjustable (A) variant at the same current, which allows the thermal pick-up to be tuned down to 80 A. Choose this fixed version when the circuit's load current is known and stable and a tamper-proof setting is preferred over field adjustability. Rated service breaking capacity (Ics) is 50% of Icu (15 kA of 30 kA) at 380\/415 V AC, in line with the 125 A frame's Category A duty. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229469577499,"sku":"G12F4F80","price":83.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g12f4f80-gopact-mccb-125.jpg?v=1790868275"},{"product_id":"schneider-g20b3a100-gopact-mccb-200-3p-100a-25ka","title":"Schneider Electric G20B3A100 GoPact MCCB 200 3P 100A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A100 is a GoPact MCCB 200 series 3-pole molded case circuit breaker rated at 100A with a breaking capacity of 25 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution and control panel applications. Engineered for demanding environments, this MCCB delivers dependable performance across a wide range of industrial automation and electrical installation scenarios. With a compact design and robust construction, the G20B3A100 is a trusted solution for protecting motors, feeders, and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides overcurrent and short-circuit protection for main and sub-distribution boards in manufacturing and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Feeder Protection:\u003c\/strong\u003e Suitable for protecting motor circuits and feeder lines in industrial automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial \u0026amp; Utility Distribution:\u003c\/strong\u003e Ideal for protecting electrical circuits in commercial buildings and utility distribution networks operating at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Boards:\u003c\/strong\u003e Used as a main or branch circuit protective device in low-voltage switchgear and controlgear assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229470626075,"sku":"G20B3A100","price":91.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a100-case-circuit-breaker_84776599-1d39-4c4b-beca-5cb8d10e0516.jpg?v=1777165161"},{"product_id":"schneider-g20b3a125-gopact-mccb-200-3p-125a-25ka","title":"Schneider Electric G20B3A125 GoPact MCCB 200 3P 125A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A125 GoPact MCCB 200 is a 3-pole 125A molded case circuit breaker rated at 415V AC with a breaking capacity of 25 kA, designed for reliable overcurrent and short-circuit protection in industrial control panels, switchboards, and distribution systems. Part of the GoPact MCCB 200 series, the G20B3A125 delivers robust performance in demanding environments where compact design and dependable protection are essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229470822683,"sku":"G20B3A125","price":105.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a125-case-circuit-breaker_c0da4107-2235-4c7c-bebe-f4a9f81c08d0.jpg?v=1777165165"},{"product_id":"schneider-electric-g20b3a160-gopact-mccb-200","title":"Schneider Electric G20B3A160 GoPact MCCB 200 3P 160 A 25 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A160 is a 3-pole GoPact MCCB 200 moulded case circuit breaker rated 160 A, built on the 200 A frame with an ultimate breaking capacity (Icu) of 25 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 12 x In (1920 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB 25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.7 x In to 1 x In (112-160 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 12 x In (1920 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.7 x In to 1 x In (112-160 A)) lets this 160 A breaker be tuned down for loads sized below the nominal 200 A frame rating, and the instantaneous pick-up is fixed at 12 x In so the magnetic trip scales with the chosen thermal setting. Unlike the 125 A frame, this 200 A frame rates Ics at 100% of Icu (25 kA of 25 kA at 380\/415 V AC), so it can clear its full fault current repeatedly without a derated service rating — a relevant factor for sub-mains where more than one fault clearance may occur before maintenance.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229470920987,"sku":"G20B3A160","price":94.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a160-gopact-mccb-200.jpg?v=1790868294"},{"product_id":"schneider-g20b3a200-gopact-mccb-3p-200a-25ka","title":"Schneider Electric G20B3A200 GoPact MCCB 3P 200A 25kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A200 GoPact MCCB is a 3-pole 200A moulded case circuit breaker rated at 25 kA breaking capacity, designed for overcurrent and short-circuit protection in industrial and commercial power distribution panels. Part of Schneider Electric's GoPact series, this compact MCCB delivers reliable protection for motor circuits, feeder circuits, and control panel applications where robust performance and space efficiency are required.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMCCB (Moulded Case Circuit Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Feeder and branch circuit protection in main distribution boards and sub-panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Short-circuit and overload protection for motor feeders in industrial automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Suitable for integration into control cabinets requiring compact 3-pole MCCB protection up to 200A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Ideal for protecting electrical installations in commercial and light-industrial facilities.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229470986523,"sku":"G20B3A200","price":142.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a200-case-circuit-breaker_42a20984-27b1-4ed9-9fc3-2e7dd21aa9fe.jpg?v=1777165169"},{"product_id":"schneider-g20b3a40-gopact-mccb-200-3p-40a-25ka","title":"Schneider Electric G20B3A40 GoPact MCCB 200 3P 40A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A40 GoPact MCCB 200 is a 3-pole molded case circuit breaker rated at 40A with a breaking capacity of 25 kA at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial power distribution panels. Designed for demanding applications where compact footprint and robust performance are essential, this MCCB delivers dependable protection for motors, feeders, and distribution boards in commercial and industrial installations. With a total weight of just 0.9 kg, the G20B3A40 offers an efficient solution for panel builders and electrical engineers requiring high-performance circuit protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471052059,"sku":"G20B3A40","price":87.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a40-case-circuit-breaker_ef8f1c20-2beb-4f14-a907-04c7ff9a1271.jpg?v=1777165173"},{"product_id":"schneider-g20b3a50-gopact-mccb-200-3p-50a-25ka","title":"Schneider Electric G20B3A50 GoPact MCCB 200 3-Pole 50A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A50 GoPact MCCB 200 is a 3-pole molded case circuit breaker rated at 50A with a breaking capacity of 25 kA at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial power distribution panels. Part of the GoPact MCCB 200 series, the G20B3A50 delivers robust performance in a compact form factor suitable for demanding commercial and industrial installations. Weighing just 0.9 kg, it is designed for straightforward DIN rail or panel mounting integration.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed and tested in accordance with IEC\/CEI international electrotechnical standards for molded case circuit breakers, ensuring compliance with global industrial safety and performance requirements.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471346971,"sku":"G20B3A50","price":87.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a50-case-circuit-breaker_52b5a767-de61-48b9-b8fb-830dea25384d.jpg?v=1777165178"},{"product_id":"schneider-g20b3a63-gopact-mccb-200-3p-63a-25ka","title":"Schneider Electric G20B3A63 GoPact MCCB 200 3P 63A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A63 GoPact MCCB 200 is a 3-pole molded case circuit breaker rated at 63A with a breaking capacity of 25 kA at 415V AC, designed for reliable overload and short-circuit protection in industrial control panels and power distribution systems. Part of the GoPact MCCB 200 series, the G20B3A63 delivers robust performance in a compact form factor suitable for demanding automation and energy management applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides reliable short-circuit and overload protection for motor control centers and distribution boards operating at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Systems:\u003c\/strong\u003e Suitable for feeder and branch circuit protection in commercial and industrial electrical installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation \u0026amp; Manufacturing:\u003c\/strong\u003e Ideal for integration into automated production lines where dependable circuit protection is critical to uptime and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e Used in energy distribution panels to safeguard downstream equipment and wiring against fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471412507,"sku":"G20B3A63","price":87.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a63-case-circuit-breaker_13070208-f682-4f04-9d4f-e5d36dc62b90.jpg?v=1777165182"},{"product_id":"schneider-g20b3a80-gopact-mccb-200-3p-80a-25ka","title":"Schneider Electric G20B3A80 GoPact MCCB 200 3P 80A 25kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B3A80 GoPact MCCB 200 is a 3-pole 80A molded case circuit breaker rated at 415V AC with a breaking capacity of 25 kA, designed for reliable overcurrent and short-circuit protection in industrial power distribution and control panels. Part of Schneider Electric's GoPact MCCB 200 series, the G20B3A80 delivers robust performance in demanding environments where dependable circuit protection is essential for both equipment and personnel safety.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B3A80\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed and tested in accordance with IEC\/CEI international electrotechnical standards for molded case circuit breakers, ensuring compliance with global industrial safety and performance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric G20B3A80 GoPact MCCB 200 is ideally suited for a wide range of industrial and commercial electrical installations, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in industrial facilities\u003c\/li\u003e\n  \u003cli\u003eMotor feeder and branch circuit protection in control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of cables, busbars, and switchgear in automation systems\u003c\/li\u003e\n  \u003cli\u003ePower distribution panels in manufacturing, infrastructure, and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eFeeder protection in machine tool and process control applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471478043,"sku":"G20B3A80","price":91.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b3a80-case-circuit-breaker_776e29d7-75a3-4fd5-8f0e-860ece3d5834.jpg?v=1777165186"},{"product_id":"schneider-electric-g20b4a100-gopact-mccb-200","title":"Schneider Electric G20B4A100 GoPact MCCB 200 4P 100 A 25 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B4A100 is a 4-pole GoPact MCCB 200 moulded case circuit breaker rated 100 A, built on the 200 A frame with an ultimate breaking capacity (Icu) of 25 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 12 x In (1200 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B4A100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB 25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.7 x In to 1 x In (70-100 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 12 x In (1200 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.7 x In to 1 x In (70-100 A)) lets this 100 A breaker be tuned down for loads sized below the nominal 200 A frame rating, and the instantaneous pick-up is fixed at 12 x In so the magnetic trip scales with the chosen thermal setting. Unlike the 125 A frame, this 200 A frame rates Ics at 100% of Icu (25 kA of 25 kA at 380\/415 V AC), so it can clear its full fault current repeatedly without a derated service rating — a relevant factor for sub-mains where more than one fault clearance may occur before maintenance. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471543579,"sku":"G20B4A100","price":99.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b4a100-gopact-mccb-200.jpg?v=1790868303"},{"product_id":"schneider-electric-g20b4a125-gopact-mccb-200","title":"Schneider Electric G20B4A125 GoPact MCCB 200 4P 125 A 25 kA TM-D Adjustable Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric G20B4A125 is a 4-pole GoPact MCCB 200 moulded case circuit breaker rated 125 A, built on the 200 A frame with an ultimate breaking capacity (Icu) of 25 kA at 380\/415 V AC. Its TM-D thermal-magnetic trip unit gives adjustable long-time overload protection (L) and instantaneous short-circuit protection (I) fixed at 12 x In (1500 A), fixed-mounted to a backplate for distribution-board incomers and feeders.\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG20B4A125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGoPact MCCB 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral pole trips at 1 x Ir, same setting as the phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB 25 kA at 380\/415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Ultimate breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA at 380\/415 V AC, 36 kA at 220\/230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-D, thermal-magnetic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLong-time (overload) pick-up Ir\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable, adjustable from 0.7 x In to 1 x In (87.5-125 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous (short-circuit) pick-up Ii\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, fixed at 12 x In (1500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, screw terminals, 25 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 130 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category \/ Pollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex H\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable Ir range (adjustable from 0.7 x In to 1 x In (87.5-125 A)) lets this 125 A breaker be tuned down for loads sized below the nominal 200 A frame rating, and the instantaneous pick-up is fixed at 12 x In so the magnetic trip scales with the chosen thermal setting. Unlike the 125 A frame, this 200 A frame rates Ics at 100% of Icu (25 kA of 25 kA at 380\/415 V AC), so it can clear its full fault current repeatedly without a derated service rating — a relevant factor for sub-mains where more than one fault clearance may occur before maintenance. The fourth pole trips the neutral at the same Ir setting as the phases (4P\/4D), so the breaker protects a 3-phase-plus-neutral feeder without a separate neutral device.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229471609115,"sku":"G20B4A125","price":125.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-g20b4a125-gopact-mccb-200.jpg?v=1790868312"}],"url":"https:\/\/stoklink.com\/collections\/schneider-gopact-mccb.oembed","provider":"Stoklink","version":"1.0","type":"link"}