{"title":"Schneider Easy TeSys Contactors","description":"\u003cp\u003eSchneider Electric Easy TeSys contactors are general-purpose three-pole power contactors for motor control. Stoklink carries over 70 Easy TeSys items from 6 A to 630 A and 2.2 kW to 335 kW. We ship worldwide from Turkey and quote project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLC1E contactors from 6 A up to 630 A in one series.\u003c\/li\u003e\n\u003cli\u003eSmall frames, such as 9 A to 38 A, with AC or DC coils.\u003c\/li\u003e\n\u003cli\u003eMid frames around 40 A to 80 A for common industrial motors.\u003c\/li\u003e\n\u003cli\u003eLarge frames, such as the 630 A LC1E630M7.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSelect by AC-3 current and kW at 400 V or your supply voltage.\u003c\/li\u003e\n\u003cli\u003eRead the coil code: for example B5 and M5 are AC codes, BD is 24 V DC.\u003c\/li\u003e\n\u003cli\u003eCheck which auxiliary contact configuration the frame offers.\u003c\/li\u003e\n\u003cli\u003eCompare with TeSys Deca if you need the wider modular accessory range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eHow is Easy TeSys different from TeSys Deca?\u003c\/h3\u003e\u003cp\u003eEasy TeSys is the simpler, lower-cost series and goes up to 630 A. TeSys Deca is the modular range up to 200 A.\u003c\/p\u003e\u003ch3\u003eWhere do I find the coil voltage?\u003c\/h3\u003e\u003cp\u003eIt is the code at the end of the part number, and it is also in the product title.\u003c\/p\u003e\u003ch3\u003eDo you ship contactors outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-lc1e0601bd-contactor","title":"Schneider Electric LC1E0601BD Easy TeSys Control LC1E 3P 6A 24VDC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0601BD is an Easy TeSys Control LC1E contactor with three main poles (3 NO), rated 6 A AC-3 at up to 440 V and a 24 V DC coil. It switches motors up to 2.2 kW at 380\/400 V and includes one normally-closed auxiliary contact, giving a fail-safe signal that opens when the contactor energizes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0601BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-3 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 380\/400 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 10s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E0601BD's 1 NC auxiliary contact opens when the contactor energizes, useful for interlocking or for signalling that the main circuit has gone live. At 6 A AC-3, it covers motors up to 2.2 kW at 380\/400 V; the same LC1E frame scales up to higher current ratings for larger motors without changing the mounting footprint. Its 24 V DC coil suits control systems already running a 24 V DC rail, avoiding a separate AC control transformer.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the motor-switching contactor in Easy TeSys Control motor-control panels and machine-building enclosures where a compact 45 mm-wide DIN-rail contactor with a 24 V DC coil and one auxiliary contact is needed for small three-phase motors.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230292087067,"sku":"LC1E0601BD","price":18.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0601bd-easy-tesys-contactor.jpg?v=1790287328"},{"product_id":"schneider-lc1e0601m5-tese-e-6a-3p-ac-contactor","title":"Schneider Electric LC1E0601M5 TeSys E 3-Pole 6A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0601M5 is a TeSys E series 3-pole AC contactor rated at 6A and 440V, designed for motor starting, stopping, and reversing applications in light industrial and commercial electrical panels. Part of Schneider's proven TeSys E contactor family, the LC1E0601M5 offers a compact footprint and reliable switching performance for low-power motor control circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0601M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Starting and stopping small 3-phase AC motors in pumps, fans, and conveyors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Industrial Panels:\u003c\/strong\u003e Used in control panels requiring compact, reliable power switching at low current ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial HVAC:\u003c\/strong\u003e Switching small motor loads in ventilation and air-handling units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Integrated into OEM machine control circuits for repetitive switching duty cycles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230292349211,"sku":"LC1E0601M5","price":15.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0601m5-440v-ac-contactor_251ce386-a42a-4eb2-b32f-35346b6d79f7.jpg?v=1777165844"},{"product_id":"schneider-electric-lc1e0610b5-easy-tesys-contactor-3p-6a","title":"Schneider Electric LC1E0610B5 Easy TeSys Contactor 3P 3NO AC-3 6 A 2.2 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0610B5 is a 3-pole Easy TeSys contactor rated 6 A AC-3 at up to 440 V, switching motors up to 2.2 kW at 400 V. It carries a 24 V AC 50 Hz coil and one built-in 1NO auxiliary contact, with power and control connections by screw clamp terminals in a 45 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0610B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW at 380\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles mechanical, 1.4 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 x 45 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 6 A AC-3, the LC1E0610B5 sits at the entry point of the Easy TeSys 3-pole range, suited to motors up to 2.2 kW at 400 V where the 45 mm frame width helps pack more starters into a panel. Its 1.4 Mcycles AC-3 electrical durability and 1800 cycles\/hour maximum operating rate fit standard duty-cycle applications; for larger motors in the same 45 mm frame, higher-current variants of this contactor family are available.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230293037339,"sku":"LC1E0610B5","price":13.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0610b5-easy-tesys-contactor-3p-6a.jpg?v=1790900832"},{"product_id":"schneider-electric-lc1e0610bd-contactor","title":"Schneider Electric LC1E0610BD Easy TeSys Control LC1E 3P 6A 24VDC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0610BD is an Easy TeSys Control LC1E contactor with three main poles (3 NO), rated 6 A AC-3 at up to 440 V and a 24 V DC coil. It switches motors up to 2.2 kW at 380\/400 V and includes one normally-open auxiliary contact, giving a confirmation signal when the contactor is energized.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0610BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-3 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 380\/400 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 10s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E0610BD's 1 NO auxiliary contact closes when the main contacts engage, giving a confirmation signal for PLC feedback or an indicator lamp — the 1 NC version in the same LC1E frame is the one to pick instead when the application needs a fail-safe open-on-energize signal. At 6 A AC-3 it covers motors up to 2.2 kW at 380\/400 V. The 24 V DC coil suits panels already running a 24 V DC control rail.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the motor-switching contactor in Easy TeSys Control motor-control panels and machine-building enclosures where a compact 45 mm-wide DIN-rail contactor with a 24 V DC coil and a run-confirmation auxiliary contact is needed for small three-phase motors.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230293725467,"sku":"LC1E0610BD","price":18.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0610bd-easy-tesys-contactor.jpg?v=1790287335"},{"product_id":"schneider-lc1e0610m5-easy-tesys-6a-3p-contactor","title":"Schneider Electric LC1E0610M5 Easy TeSys 3-Pole 6A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0610M5 is a 3-pole AC contactor from the Easy TeSys series, rated at 6A and 440V for dependable motor and load switching in industrial control applications. Designed for compact panel installations, this power contactor delivers robust performance across AC-3 utilization categories, making it an ideal choice for engineers and procurement professionals seeking a reliable motor starter contactor solution.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0610M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Suitable for direct-on-line starting and stopping of three-phase induction motors in AC-3 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Compact 3-pole design fits standard DIN rail assemblies for machine control and automation panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Switching:\u003c\/strong\u003e Reliable switching of resistive and inductive loads in AC-1 utilization category applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Often paired with thermal overload relays to form a complete motor starter solution for pumps, fans, and conveyors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230294216987,"sku":"LC1E0610M5","price":15.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0610m5-440v-ac-contactor_4b258818-6c3f-4916-97d8-d15805818be8.jpg?v=1777165849"},{"product_id":"schneider-electric-lc1e0901b5-easy-tesys-contactor-3p-9a","title":"Schneider Electric LC1E0901B5 Easy TeSys Contactor 3P 3NO AC-3 9 A 4 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0901B5 is a 3-pole Easy TeSys contactor rated 9 A AC-3 at up to 440 V, switching motors up to 4 kW at 400 V. It carries a 24 V AC 50 Hz coil and one built-in 1NC auxiliary contact, with power and control connections by screw clamp terminals in a 45 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0901B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW at 380\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.5 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles mechanical, 1.4 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 x 45 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E0901B5 covers motors up to 4 kW at 400 V in the same 45 mm frame as the smaller Easy TeSys units, with its built-in 1NC contact wired directly for stop-circuit or alarm feedback without a separate accessory block. A 20 A gG fuse upstream gives type-1 coordination per the verified rating; for lower or higher motor power in the same footprint, adjacent current steps of this contactor family are available.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230296248603,"sku":"LC1E0901B5","price":13.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0901b5-easy-tesys-contactor-3p-9a.jpg?v=1790900841"},{"product_id":"schneider-electric-lc1e0901bd-contactor","title":"Schneider Electric LC1E0901BD Easy TeSys Control LC1E 3P 9A 24VDC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0901BD is an Easy TeSys Control LC1E contactor with three main poles (3 NO), rated 9 A AC-3 at up to 440 V and a 24 V DC coil. It switches motors up to 4 kW at 380\/400 V and includes one normally-closed auxiliary contact, giving a fail-safe signal that opens when the contactor energizes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0901BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-3 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 380\/400 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.5 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 10s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3, the LC1E0901BD covers motors up to 4 kW at 380\/400 V, one step above the 6 A LC1E frame in the same Easy TeSys Control range. Its 1 NC auxiliary contact opens when the contactor energizes, useful for interlocking or signalling that the main circuit is live — pick the 1 NO version instead if the application needs a run-confirmation signal. The 24 V DC coil suits control panels already running a 24 V DC rail.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the motor-switching contactor in Easy TeSys Control motor-control panels and machine-building enclosures where a compact 45 mm-wide DIN-rail contactor with a 24 V DC coil and one auxiliary contact is needed for mid-size three-phase motors.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230296838427,"sku":"LC1E0901BD","price":20.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0901bd-easy-tesys-contactor.jpg?v=1790287342"},{"product_id":"schneider-lc1e0901m5-easypact-tvs-9a-3p-contactor","title":"Schneider Electric LC1E0901M5 EasyPact TVS 3P 9A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0901M5 is a 3-pole 9A AC contactor from the EasyPact TVS series, designed for reliable motor switching and power control in industrial and commercial electrical installations. Rated at 440V with a compact, lightweight design weighing just 0.3 kg, this contactor delivers dependable performance for motor starter and load switching applications where space and efficiency matter.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0901M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line starting of 3-phase AC motors in pumps, fans, compressors, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Panels:\u003c\/strong\u003e Suitable for integration into motor control centres (MCCs) and distribution boards requiring compact contactor solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Effective for switching resistive and inductive loads in AC-1 and AC-3 utilization categories across manufacturing and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Equipment:\u003c\/strong\u003e Widely used by machine builders requiring a reliable, standardised contactor with a small footprint.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230297461019,"sku":"LC1E0901M5","price":15.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0901m5-440v-ac-contactor_009b71aa-35f7-45da-bb89-b8618309b09c.jpg?v=1777165853"},{"product_id":"schneider-lc1e0910b5-lc1e-9a-3pole-440v-contactor","title":"Schneider Electric LC1E0910B5 LC1E 3-Pole 9A 440V 24V AC Coil Easy TeSys Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0910B5 is an Easy TeSys series 3-pole AC contactor rated at 9A and 440V, designed for motor switching and control applications in industrial and commercial installations. Referenced as model LC1E, this contactor delivers 4kW motor power at 380–400V AC (AC-3 utilization category) and operates on a 24V AC coil, making it suitable for low-control-voltage automation systems. With DIN rail and plate mounting options and a compact footprint of 74mm × 45mm × 80mm, the LC1E0910B5 integrates easily into standard control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0910B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 A at 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW at 380–400V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail, Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 mm × 45 mm × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-30:\u003c\/strong\u003e Environmental testing — damp heat cyclic test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 6095-2-1:\u003c\/strong\u003e Environmental testing standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity marking for Russia\/CIS market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC motor starting and stopping in pump, fan, and compressor applications\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and machine control panels requiring compact 3-pole contactors\u003c\/li\u003e\n\u003cli\u003eLow-control-voltage circuits (24V AC coil) in safety-sensitive or PLC-driven systems\u003c\/li\u003e\n\u003cli\u003eCommercial HVAC and building services motor control\u003c\/li\u003e\n\u003cli\u003eOEM machine builders requiring DIN rail-mountable power contactors up to 4kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230298083611,"sku":"LC1E0910B5","price":15.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0910b5-easy-tesys-contactor_c3a333d2-5b94-4dd1-b061-c969d1f9ceaa.jpg?v=1777165861"},{"product_id":"schneider-electric-lc1e0910bd-contactor","title":"Schneider Electric LC1E0910BD Easy TeSys Control LC1E 3P 9A 24VDC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0910BD is an Easy TeSys Control LC1E contactor with three main poles (3 NO), rated 9 A AC-3 at up to 440 V and a 24 V DC coil. It switches motors up to 4 kW at 380\/400 V and includes one normally-open auxiliary contact, giving a confirmation signal when the contactor is energized.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0910BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-3 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 380\/400 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.5 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 10s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 9 A AC-3, the LC1E0910BD covers motors up to 4 kW at 380\/400 V, one step above the 6 A LC1E frame in the same Easy TeSys Control range. Its 1 NO auxiliary contact closes when the main contacts engage, giving a confirmation signal for PLC feedback or an indicator lamp — pick the 1 NC version instead when the application needs a fail-safe open-on-energize signal. The 24 V DC coil suits control panels already running a 24 V DC rail.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the motor-switching contactor in Easy TeSys Control motor-control panels and machine-building enclosures where a compact 45 mm-wide DIN-rail contactor with a 24 V DC coil and a run-confirmation auxiliary contact is needed for mid-size three-phase motors.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230299459867,"sku":"LC1E0910BD","price":20.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0910bd-easy-tesys-contactor.jpg?v=1790287348"},{"product_id":"schneider-lc1e0910m5-easy-tesys-9a-3p-contactor","title":"Schneider Electric LC1E0910M5 Easy TeSys 3-Pole 9A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E0910M5 is a 3-pole 9A 440V AC contactor from the Easy TeSys series, designed for reliable motor switching and industrial control applications. Rated at 9A across three poles, this compact contactor delivers consistent performance in automation, motor starter, and power control circuits where space-efficient design and dependable operation are essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E0910M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Stopping:\u003c\/strong\u003e Ideal for direct-on-line starting of small three-phase motors in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Panels:\u003c\/strong\u003e Suitable for integration into control panels and automation systems requiring compact switching devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pump Control:\u003c\/strong\u003e Used in heating, ventilation, air conditioning, and pump motor control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Machine Tools:\u003c\/strong\u003e Applied in conveyor drive control and general machine tool automation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230299787547,"sku":"LC1E0910M5","price":15.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e0910m5-440v-ac-contactor_499e8d0a-e66f-4fbf-a9f7-276062211f8b.jpg?v=1777165866"},{"product_id":"schneider-electric-lc1e1201b5-easy-tesys-contactor-3p-12a","title":"Schneider Electric LC1E1201B5 Easy TeSys Contactor 3P 3NO AC-3 12 A 5.5 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1201B5 is a 3-pole Easy TeSys contactor rated 12 A AC-3 at up to 440 V, switching motors up to 5.5 kW at 400 V. It carries a 24 V AC 50 Hz coil and one built-in 1NC auxiliary contact, with power and control connections by screw clamp terminals in a 45 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1201B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW at 380\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles mechanical, 1.4 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 x 45 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12 A AC-3 and 5.5 kW at 400 V, the LC1E1201B5 is the top current step that still fits the compact 45 mm Easy TeSys frame shared with the 6 A and 9 A units, useful where panel width is tight. The same 25 A gG associated fuse rating as the 9 A variant simplifies spare-parts standardisation across a panel that mixes both current ratings; for motors above 5.5 kW, the wider-frame Easy TeSys contactors are needed instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230301294875,"sku":"LC1E1201B5","price":14.63,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1201b5-easy-tesys-contactor-3p-12a.jpg?v=1790900849"},{"product_id":"schneider-lc1e1201m5-easy-tesys-12a-3p-440v-contactor","title":"Schneider Electric LC1E1201M5 Easy TeSys 3-Pole 12A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1201M5 is a 3-pole AC contactor from the Easy TeSys series, rated at 12A and 440V for dependable motor switching and power control in industrial applications. Designed for high-cycle switching duties, the LC1E1201M5 delivers consistent performance in motor starter circuits, HVAC systems, and general-purpose load control. Its compact Easy TeSys design integrates seamlessly into control panels and distribution boards where space and reliability are paramount.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1201M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for DOL (direct-on-line) motor starter circuits in AC-3 utilization category up to 12A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Suitable for fan, pump, and compressor control in heating, ventilation, and air-conditioning installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Used in PLC-controlled panels for switching resistive and inductive loads in manufacturing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Power Control:\u003c\/strong\u003e Appropriate for lighting circuits, heating elements, and other AC-1 category loads in commercial and industrial settings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230301557019,"sku":"LC1E1201M5","price":16.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1201m5-440v-ac-contactor_0612196c-6ec0-491f-bde5-df78a1a9092f.jpg?v=1777165871"},{"product_id":"schneider-lc1e120m5-tesyns-e-120a-3p-contactor","title":"Schneider Electric LC1E120M5 TeSys E 3-Pole 120A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E120M5 is a TeSys E series 3-pole AC contactor rated at 120A and 440V AC, engineered for demanding motor control and power switching applications in industrial environments. Designed to meet the high-cycle switching requirements of modern automation systems, the LC1E120M5 delivers robust and reliable performance in AC-3 and AC-1 utilization categories. Weighing just 0.3 kg, this compact power contactor integrates seamlessly into panel builds where space and weight are critical considerations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E120M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line (DOL) motor starters controlling three-phase induction motors up to 120A rated current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in industrial panels and machinery control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Compatible with PLC-driven control architectures requiring reliable high-current switching in AC-3 and AC-1 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pumping:\u003c\/strong\u003e Frequently deployed in pump, fan, and compressor motor control applications where robust cycle endurance is essential.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230301917467,"sku":"LC1E120M5","price":193.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e120m5-440v-ac-contactor_c87dbf0b-2806-47f7-8e5d-f4f0067993be.jpg?v=1777165875"},{"product_id":"schneider-lc1e1210b5-lc1e-12a-3pole-440v-contactor","title":"Schneider Electric LC1E1210B5 LC1E Easy TeSys 3-Pole 12A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1210B5 is an Easy TeSys series 3-pole AC contactor rated at 12A and 440V, designed for motor switching and industrial power control applications. Part of Schneider's proven LC1E range, this contactor delivers reliable performance in AC-3 motor starter duties, making it a trusted choice for panel builders, OEMs, and industrial automation engineers. Compact and robust, the LC1E1210B5 fits seamlessly into standard control panel assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1210B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for AC-3 duty — direct-on-line starting and switching of squirrel cage induction motors up to 12A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for integration into motor control centres (MCCs), control panels, and automated production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pump Control:\u003c\/strong\u003e Used in fan, pump, and compressor control systems where reliable contactor switching is essential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Compact form factor and standard DIN rail mounting make the LC1E1210B5 an excellent choice for machine builders requiring space-efficient solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230302572827,"sku":"LC1E1210B5","price":16.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1210b5-440v-ac-contactor_60bc838a-56c9-45d3-94ef-ec52598e4492.jpg?v=1777165879"},{"product_id":"schneider-lc1e1210m5-easy-tesys-12a-3p-contactor","title":"Schneider Electric LC1E1210M5 Easy TeSys 3-Pole 12A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1210M5 is a 3-pole AC contactor from the Easy TeSys series, rated at 12A and 440V AC, designed for motor switching and industrial power control applications. Built for reliable performance in demanding environments, the LC1E1210M5 delivers dependable contactor operation across a wide range of AC-3 motor load duties. Compact in form and robust in construction, this Easy TeSys contactor is a trusted choice for panel builders and systems integrators.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1210M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230303621403,"sku":"LC1E1210M5","price":16.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1210m5-440v-ac-contactor_5e03bedb-b081-4d77-baeb-d3f974b34e36.jpg?v=1777165883"},{"product_id":"schneider-electric-lc1e160b5-easy-tesys-contactor-3p-160a","title":"Schneider Electric LC1E160B5 Easy TeSys Contactor 3P 3NO AC-3 160 A 80 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E160B5 is a 3-pole Easy TeSys contactor rated 160 A AC-3 at up to 440 V, switching motors up to 80 kW at 415\/440 V. It carries a 24 V AC 50 Hz coil and built-in 1NO+1NC auxiliary contacts, with power connections by screw clamp terminals in a 120 mm wide DIN-rail or plate-mounted housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E160B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kW at 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mcycles mechanical, 0.8 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158 x 120 x 132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E160B5 is sized for 80 kW motors at 415\/440 V and needs a 315 A gG fuse upstream for type-1 coordination at its 1280 A rated breaking capacity. With built-in 1NO+1NC contacts it covers both a run-feedback and a stop-interlock signal without an add-on block; its 0.8 Mcycles AC-3 durability and 1200 cycles\/hour maximum rate reflect the heavier contact mass of this current class compared with the smaller-frame Easy TeSys units.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230304440603,"sku":"LC1E160B5","price":227.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e160b5-easy-tesys-contactor-3p-160a.jpg?v=1790900858"},{"product_id":"schneider-lc1e160m5-easy-tesys-160a-3pole-contactor","title":"Schneider Electric LC1E160M5 Easy TeSys 3-Pole 160A 440V AC Contactor","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric LC1E160M5\u003c\/strong\u003e is a 3-pole 160A AC power contactor from the \u003cstrong\u003eEasy TeSys\u003c\/strong\u003e series, designed for motor switching and industrial load control applications up to 440V. Built for demanding environments, this contactor delivers dependable performance in motor starter assemblies, industrial control panels, and power distribution systems where robust switching capability is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E160M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line (DOL) motor starter circuits controlling three-phase induction motors in industrial machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in control panels and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Commonly deployed in manufacturing lines, conveyor systems, pumping stations, and HVAC equipment requiring reliable contactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Compatible with thermal overload relays and manual motor starters for comprehensive motor protection solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230305456411,"sku":"LC1E160M5","price":218.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e160m5-440v-ac-contactor_e5594294-fef2-4ab3-b5a9-5e4734407a19.jpg?v=1777165888"},{"product_id":"schneider-electric-lc1e18004m7-easy-tesys-contactor-4p-32a","title":"Schneider Electric LC1E18004M7 Easy TeSys Contactor 4P 4NO AC-1 32 A 220 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E18004M7 is a 4-pole Easy TeSys contactor rated 32 A AC-1 for resistive-load switching at up to 440 V. It carries a 220 V AC 50\/60 Hz coil with power and control connections by screw clamp terminals in a 45 mm wide DIN-rail housing, with no built-in auxiliary contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E18004M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤440 V AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles mechanical, 0.3 Mcycles electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 x 45 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs an AC-1 only contactor, the LC1E18004M7 is rated for resistive or low-inrush loads such as heating banks rather than motor starting, so its 32 A rating is not comparable to an AC-3 motor contactor of the same current. Four normally-open poles switch all four conductors of a resistive circuit together, useful on 3-phase-plus-neutral heating loads; where motor switching is required, the 3-pole AC-3 Easy TeSys contactors should be used instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230306144539,"sku":"LC1E18004M7","price":24.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e18004m7-easy-tesys-contactor-4p-32a.jpg?v=1790900866"},{"product_id":"schneider-lc1e1801b5-easypact-tvs-18a-3p-contactor","title":"Schneider Electric LC1E1801B5 EasyPact TVS 3P 18A 24V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1801B5 is an EasyPact TVS series 3-pole contactor rated at 18 A and 440 V, designed for efficient motor switching and load control in industrial applications. Featuring a 24 V AC coil, this LC1E contactor delivers dependable AC-3 utilization category performance for direct-on-line motor starting, making it a cost-effective solution for panel builders and OEMs seeking compact, reliable power switching.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1801B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting:\u003c\/strong\u003e Ideal for direct-on-line (DOL) starting of three-phase induction motors up to 18 A rated current in AC-3 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Suitable for controlling pumps, fans, compressors, and conveyor drives in manufacturing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Compact footprint makes the LC1E1801B5 well-suited for space-constrained motor control centers and switchboards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Reliable coil switching performance for heating, ventilation, and air-conditioning load management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Equipment:\u003c\/strong\u003e The EasyPact TVS range is widely adopted by OEMs for cost-optimized yet robust power contactor solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230306504987,"sku":"LC1E1801B5","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1801b5-ac-coil-contactor_5b977082-83a7-4859-b28a-bac5004c0b61.jpg?v=1777165892"},{"product_id":"schneider-lc1e1801m5-tesze-18a-3p-contactor","title":"Schneider Electric LC1E1801M5 TeSys E 3-Pole 18A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1801M5 is a TeSys E series 3-pole AC contactor rated at 18A and 440V, designed for motor starting, stopping, and reversing applications in industrial control panels. Built to IEC standards, this power contactor delivers dependable switching performance in AC-3 motor control duties, making it a trusted choice for engineers and panel builders specifying reliable contactors in automation and industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1801M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting and stopping 3-phase induction motors in AC-3 utilization category applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Panels:\u003c\/strong\u003e Suitable for integration into motor control centers (MCCs), distribution boards, and automation panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Commonly used for controlling pumps, fans, compressors, and conveyor drives in process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Applicable to AC-1 resistive and slightly inductive load switching in building services and industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230307094811,"sku":"LC1E1801M5","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1801m5-440v-ac-contactor_c15408d5-c92f-4ae4-8546-d24e3431a3ec.jpg?v=1777165897"},{"product_id":"schneider-lc1e1810b5-easy-tesys-18a-3pole-contactor","title":"Schneider Electric LC1E1810B5 Easy TeSys 3-Pole 18A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1810B5 is an Easy TeSys series 3-pole AC contactor rated at 18A and 440V, designed for motor starting, stopping, and reversing applications in industrial control panels. This power contactor delivers dependable switching performance for AC-3 utilization category loads, making it a go-to solution for engineers and panel builders seeking a compact, reliable motor starter contactor. The LC1E1810B5 weighs just 0.3 kg, enabling space-efficient installations in demanding environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1810B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line starting and stopping of three-phase AC motors in AC-3 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Suited for conveyors, pumps, fans, compressors, and HVAC systems requiring reliable motor starter contactor switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Compact 0.3 kg form factor integrates easily into motor control centres (MCCs) and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversing Starters:\u003c\/strong\u003e Can be used in paired configurations for motor reversing duties typical in manufacturing lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Contactor Applications:\u003c\/strong\u003e Suitable for resistive and inductive load switching across AC-1 and AC-3 utilization categories.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230307389723,"sku":"LC1E1810B5","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1810b5-440v-ac-contactor_585c05f4-62a5-45c4-a286-bca11c03a727.jpg?v=1777165901"},{"product_id":"schneider-lc1e1810m5-easy-tesys-18a-3pole-contactor","title":"Schneider Electric LC1E1810M5 Easy TeSys 3-Pole 18A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E1810M5 is a 3-pole 18A AC contactor from the Easy TeSys series, designed for motor control and power switching applications in industrial environments. Rated at 440V and weighing 4.6 kg, this LC1E series contactor delivers dependable switching performance for AC motor loads and resistive circuits. The LC1E1810M5 is a core component for panel builders and OEMs requiring compact, robust contactors across a wide range of industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E1810M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting, stopping, and reversing three-phase AC motors in industrial machinery and HVAC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in manufacturing, process control, and building automation panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Commonly paired with thermal overload relays to form complete motor starter solutions in MCC panels and control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM \u0026amp; Panel Building:\u003c\/strong\u003e Compact form factor and Easy TeSys design make the LC1E1810M5 a preferred choice for panel builders requiring reliable, space-efficient contactors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230308307227,"sku":"LC1E1810M5","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e1810m5-440v-ac-contactor_0827bda9-f0e4-48f9-9eeb-7b21c7b154d5.jpg?v=1777165905"},{"product_id":"schneider-electric-lc1e200b5-easy-tesys-contactor-3p-200a","title":"Schneider Electric LC1E200B5 Easy TeSys Contactor 3P 3NO AC-3 200 A 100 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E200B5 is a 3-pole Easy TeSys contactor rated 200 A AC-3 at up to 440 V, switching motors up to 100 kW at 415\/440 V. It carries a 24 V AC 50 Hz coil with no built-in auxiliary contacts, power connections by cable lug or busbar, and control connections by screw clamp terminals in a 168.5 mm wide plate-mounted housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E200B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kW at 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Mcycles mechanical, 0.5 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e174 x 168.5 x 181 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 200 A AC-3 for 100 kW motors, the LC1E200B5 connects by cable lug or 3x25 mm busbar rather than screw clamp terminals, reflecting the higher power circuit current at this frame size. It ships without built-in auxiliary contacts, so feedback signalling needs an add-on auxiliary contact block; for motors above 100 kW at 415\/440 V, the next frame size up in this contactor family is required.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230309355803,"sku":"LC1E200B5","price":330.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e200b5-easy-tesys-contactor-3p-200a.jpg?v=1790900875"},{"product_id":"schneider-lc1e200m5-easypact-tvs-200a-3p-contactor","title":"Schneider Electric LC1E200M5 EasyPact TVS 3P 200A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E200M5 is an EasyPact TVS series 3-pole AC contactor rated at 200 A and 440 V, designed for reliable motor starting and power switching in industrial applications. Part of Schneider's trusted EasyPact TVS line, the LC1E200M5 delivers robust switching performance in a compact footprint suited for panel builders and OEM machine builders demanding dependable load control.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E200M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting and stopping large three-phase induction motors in pumping, HVAC, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in industrial distribution boards and MCC panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Commonly integrated into motor control centers and industrial machinery requiring reliable 200 A switching capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding \u0026amp; Infrastructure:\u003c\/strong\u003e Used in commercial building services for compressor and fan motor control applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230309978395,"sku":"LC1E200M5","price":317.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e200m5-440v-ac-contactor_ae38935e-1ab3-4d4c-bfcd-99d8e35d0f3c.jpg?v=1777165910"},{"product_id":"schneider-electric-lc1e25004m7-easy-tesys-contactor-4p-40a","title":"Schneider Electric LC1E25004M7 Easy TeSys Contactor 4P 4NO AC-1 40 A 220 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E25004M7 is a 4-pole Easy TeSys contactor rated 40 A AC-1 for resistive-load switching at up to 440 V. It carries a 220 V AC 50\/60 Hz coil with built-in 4NO auxiliary contacts, power and control connections by screw clamp terminals in a 45 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E25004M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at ≤440 V AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Mcycles mechanical, 0.35 Mcycles electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 56 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E25004M7 is rated AC-1 only, so its 40 A figure applies to resistive loads such as heating elements and must not be read against AC-3 motor contactors of similar current. Four normally-open poles let it switch a complete 3-phase-plus-neutral heating circuit in one device; where motor starting is the application, the 3-pole AC-3 Easy TeSys contactors are the correct choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230310666523,"sku":"LC1E25004M7","price":34.27,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e25004m7-easy-tesys-contactor-4p-40a.jpg?v=1790900885"},{"product_id":"schneider-electric-lc1e2501b5-easy-tesys-contactor-3p-25a","title":"Schneider Electric LC1E2501B5 Easy TeSys Contactor 3P 3NO AC-3 25 A 11 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E2501B5 is a 3-pole Easy TeSys contactor rated 25 A AC-3 at up to 440 V, switching motors up to 11 kW at 415\/440 V. It carries a 24 V AC 50 Hz coil and one built-in 1NC auxiliary contact, with power and control connections by screw clamp terminals in a 45.5 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E2501B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW at 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e212.5 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles mechanical, 1.2 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 x 45 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E2501B5 covers 11 kW motors at 415\/440 V with its 25 A AC-3 rating, needing only a 40 A gG fuse upstream for type-1 coordination. Its built-in 1NC contact wires directly into a stop or alarm circuit without an accessory block, and the 1.2 Mcycles AC-3 durability sits between the lower-current and higher-current steps of the same frame; for motors just below or above 11 kW, the adjacent current ratings of this contactor family are available.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230310764827,"sku":"LC1E2501B5","price":24.86,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e2501b5-easy-tesys-contactor-3p-25a.jpg?v=1790900894"},{"product_id":"schneider-lc1e2501m5-easypact-tvs-25a-3p-contactor","title":"Schneider Electric LC1E2501M5 EasyPact TVS 3-Pole 25A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E2501M5 is an EasyPact TVS series 3-pole AC contactor rated at 25A and 440V, designed for motor switching and industrial power control applications. Part of the trusted LC1E range, this contactor delivers reliable performance for AC-3 load control in commercial and industrial installations. Weighing 4.7 kg, it is built for robust, continuous-duty operation in demanding environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E2501M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for starting, stopping, and reversing AC induction motors in AC-3 utilization category applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for integration into motor control centers (MCCs), panel boards, and automated machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pumping Systems:\u003c\/strong\u003e Used in compressors, fans, pumps, and conveyor drives requiring reliable 3-phase switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Applicable in building management systems for lighting, HVAC, and general-purpose load control.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230310994203,"sku":"LC1E2501M5","price":28.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e2501m5-440v-ac-contactor_446e1db4-f078-48b0-b57e-15d8183b04f7.jpg?v=1777165916"},{"product_id":"schneider-electric-lc1e250b5-easy-tesys-contactor-3p-250a","title":"Schneider Electric LC1E250B5 Easy TeSys Contactor 3P 3NO AC-3 250 A 140 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E250B5 is a 3-pole Easy TeSys contactor rated 250 A AC-3 at up to 440 V, switching motors up to 140 kW at 415\/440 V. It carries a 24 V AC 50 Hz coil with no built-in auxiliary contacts, power connections by cable lug or busbar, and control connections by screw clamp terminals in a 168.5 mm wide plate-mounted housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E250B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 kW at 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Mcycles mechanical, 0.7 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e197 x 168.5 x 181 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E250B5 is the highest-current Easy TeSys 3-pole contactor in this data set, sized for 140 kW motors at 415\/440 V, and its IP00 rating means the power terminals are open and the device needs an enclosure that itself provides touch protection. Power connects by 32x4 mm busbar or cable lug rather than screw terminals; for motors below 140 kW, the lower-current steps of this frame are available with screw-terminal power connections.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230311289115,"sku":"LC1E250B5","price":416.07,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e250b5-easy-tesys-contactor-3p-250a.jpg?v=1790900902"},{"product_id":"schneider-lc1e250m5-easy-tesys-250a-3p-440v-contactor","title":"Schneider Electric LC1E250M5 Easy TeSys 3-Pole 250A 440V AC Power Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E250M5 is a 3-pole 250A AC power contactor from the Easy TeSys series, engineered for reliable motor switching and load control in industrial installations up to 440V. Designed for demanding AC-3 and AC-1 utilization categories, the LC1E250M5 offers robust performance in motor starter, reversing, and power distribution applications. Its compact construction and wide coil voltage compatibility make it a versatile solution for panel builders and OEMs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E250M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements for electrical equipment\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230311551259,"sku":"LC1E250M5","price":400.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e250m5-ac-power-contactor_a8ba8563-f84e-4029-9448-4996e9a98b02.jpg?v=1777165921"},{"product_id":"schneider-lc1e2510b5-tesyns-e-25a-3p-contactor","title":"Schneider Electric LC1E2510B5 TeSys E 3-Pole 25A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E2510B5 is a TeSys E series 3-pole AC contactor rated at 25A and 440V AC, designed for reliable motor switching and power control in industrial applications. Part of Schneider's proven TeSys E contactor range, the LC1E2510B5 delivers dependable performance under AC-3 utilization category conditions, making it well-suited for direct-on-line motor starters and general load switching duties. Weighing just 0.36 kg, this compact contactor is an efficient solution for panel builders and system integrators seeking a trusted Schneider Electric switching device.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E2510B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230311747867,"sku":"LC1E2510B5","price":28.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e2510b5-440v-ac-contactor_b4c02021-015d-40cf-b69b-17d684ab9b5e.jpg?v=1777165925"},{"product_id":"schneider-electric-lc1e2510bd-contactor","title":"Schneider Electric LC1E2510BD Easy TeSys Control LC1E 3P 25A 24VDC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E2510BD is an Easy TeSys Control LC1E contactor with three main poles (3 NO), rated 25 A AC-3 at up to 440 V and a 24 V DC coil. It switches motors up to 11 kW at 380\/400 V and includes one normally-open auxiliary contact, giving a confirmation signal when the contactor is energized.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E2510BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-3 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie), AC-1 at ≤440V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 380\/400 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e212.5 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Time Withstand Current (Icw), 10s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Circuit Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew clamp, up to 10 mm² (cable end) \/ 6 mm² solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5…55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 x 77 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 A AC-3, the LC1E2510BD is the largest current rating in this Easy TeSys Control LC1E selection, covering motors up to 11 kW at 380\/400 V versus 2.2-4 kW on the 6-9 A frames in the same range. Its power-circuit terminals accept up to 10 mm² flexible cable with a cable end, versus 4 mm² on the smaller frames, so check cable sizing before substituting a lower-current LC1E for the same conductor. The 1 NO auxiliary contact closes when the contactor energizes, giving feedback for PLC monitoring or run-indication.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the motor-switching contactor in Easy TeSys Control motor-control panels and machine-building enclosures where a compact DIN-rail contactor with a 24 V DC coil is needed for larger three-phase motors up to 11 kW.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230311813403,"sku":"LC1E2510BD","price":38.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e2510bd-easy-tesys-contactor.jpg?v=1790287355"},{"product_id":"schneider-lc1e2510m5-tesyns-e-25a-3p-contactor","title":"Schneider Electric LC1E2510M5 TeSys E 3-Pole 25A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E2510M5 is a TeSys E series 3-pole AC contactor rated at 25A and 440V, designed for motor starting, stopping, and reversing applications in industrial control panels. Built to IEC standards, this power contactor delivers dependable performance for AC-3 utilization category loads including squirrel-cage induction motors. Weighing 8.5 kg, the LC1E2510M5 is a robust solution for demanding motor control environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E2510M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting and stopping squirrel-cage induction motors in AC-3 duty cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Panels:\u003c\/strong\u003e Suitable for integration into motor control centers (MCCs) and industrial distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Used in AC-1 resistive and AC-3 inductive motor load switching applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machinery:\u003c\/strong\u003e Commonly specified in machine tool, conveyor, pump, and fan control systems requiring a reliable motor starter contactor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230311977243,"sku":"LC1E2510M5","price":28.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e2510m5-440v-ac-contactor_be687f67-48a4-45a8-85c0-a6d3513fe74f.jpg?v=1777165930"},{"product_id":"schneider-lc1e300m5-easypact-tvs-300a-3pole-contactor","title":"Schneider Electric LC1E300M5 EasyPact TVS 3-Pole 300A AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E300M5 is a 3-pole 300A AC contactor from the EasyPact TVS series, engineered for reliable switching of motors and heavy industrial loads at up to 440V. Designed for demanding industrial environments, the LC1E300M5 delivers robust performance in motor starter and power distribution applications, combining a compact footprint with high current capacity to meet the needs of engineers and procurement professionals seeking dependable control solutions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E300M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Suitable for AC-3 and AC-1 utilization categories, making the LC1E300M5 ideal for direct-on-line motor starters in pumps, compressors, fans, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Used as a main power contactor in motor control centers (MCCs) and distribution panels for switching resistive and inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Integrates into PLC-controlled automation systems requiring high-current switching with coil voltage flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Building Services:\u003c\/strong\u003e Deployed in large HVAC units, chiller plants, and building services equipment requiring reliable 300A load control.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230312337691,"sku":"LC1E300M5","price":503.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e300m5-300a-ac-contactor_48a98a32-68fe-48d0-8336-326229578594.jpg?v=1777165935"},{"product_id":"schneider-lc1e3201m5-easypact-tvs-32a-3p-440v-contactor","title":"Schneider Electric LC1E3201M5 EasyPact TVS 32A 3P 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3201M5 is a 32A 3-pole AC contactor from the EasyPact TVS series, designed for motor control and industrial power switching applications up to 440V. Built for reliable performance in demanding environments, this power contactor delivers dependable operation for motor starters, HVAC systems, and industrial automation circuits where consistent switching performance is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3201M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for starting and stopping three-phase AC motors in pumps, fans, compressors, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Suitable for controlling heating, ventilation, and air conditioning equipment requiring reliable 3-pole switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Used in control panels and motor control centres (MCCs) for automated machinery switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Applicable for switching resistive and inductive loads in commercial and light industrial installations up to 440V.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230312534299,"sku":"LC1E3201M5","price":42.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3201m5-440v-ac-contactor_c95c4966-5010-48b8-abbb-70e1045359f9.jpg?v=1777165939"},{"product_id":"schneider-electric-lc1e3210b5-easy-tesys-contactor-3p-32a","title":"Schneider Electric LC1E3210B5 Easy TeSys Contactor 3P 3NO AC-3 32 A 15 kW 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3210B5 is a 3-pole Easy TeSys contactor rated 32 A AC-3 at up to 440 V, switching motors up to 15 kW at 415\/440 V. It carries a 24 V AC 50 Hz coil and one built-in 1NO auxiliary contact, with power and control connections by screw clamp terminals in a 56 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3210B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, 3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3, AC-3e, AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at ≤440 V AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW at 415\/440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e272 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\/Electrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Mcycles mechanical, 1 Mcycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84 x 56 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LC1E3210B5 moves up to a 56 mm frame from the 45 mm bodies of the lower-current Easy TeSys contactors, sized for 15 kW motors at 415\/440 V with a 63 A gG fuse for type-1 coordination. Its built-in 1NO contact suits run-indication wiring, and the 1 Mcycles AC-3 durability matches the heavier contact structure of this current step; for motors above 15 kW, the next current rating in this frame size is available.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230312665371,"sku":"LC1E3210B5","price":37.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3210b5-easy-tesys-contactor-3p-32a.jpg?v=1790900910"},{"product_id":"schneider-electric-lc1e3210bd-easy-tesys-32a-contactor","title":"Schneider Electric LC1E3210BD Easy TeSys Control LC1E 32A 3P 400V 15kW Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3210BD is a 3-pole Easy TeSys Control contactor rated 32 A (AC-3) at up to 440 V AC, built for direct-on-line motor control up to 15 kW at 400 V. It carries a 24 V DC coil and one NO auxiliary contact, making it a compact DIN-rail or plate-mount switching device for control panels and motor starter combinations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3210BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 A \/ 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416 A at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e272 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 56 x 99 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 32 A AC-3 rating supports direct-on-line starting of motors up to 15 kW at 400 V AC, while the separate 50 A AC-1 rating applies only to resistive or heating loads, not motor circuits. A 24 V DC coil suits control panels standardized on low-voltage DC control power rather than mains-referenced AC coils. The single NO auxiliary contact provides one spare signal for a motor-running indication, interlock, or PLC feedback point without an add-on auxiliary contact block. The 260 A \/ 10 s short-time withstand current gives margin to ride through inrush conditions under coordinated fuse protection (63 A gG, type 1).\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230312730907,"sku":"LC1E3210BD","price":50.33,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3210bd-easy-tesys-contactor.jpg?v=1790287365"},{"product_id":"schneider-lc1e3210m5-easy-tesys-32a-3pole-contactor","title":"Schneider Electric LC1E3210M5 Easy TeSys 3-Pole 32A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3210M5 is a 3-pole 32A AC contactor from the Easy TeSys series, designed for reliable motor switching and power control in industrial automation applications. Rated at 440V and weighing just 0.45 kg, this compact contactor delivers dependable performance in panel-board and control cabinet installations. The LC1E series is engineered to meet the demanding requirements of motor starter and power contactor applications across a wide range of industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3210M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for direct-on-line starting and stopping of 3-phase induction motors in AC-3 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for use in motor control centres (MCCs), control panels, and machine automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Can be used as a power contactor for resistive and inductive load switching in AC-1 duty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Control:\u003c\/strong\u003e Commonly applied in HVAC, water treatment, and process industries for pump and fan motor control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Compressor Drives:\u003c\/strong\u003e Suitable for frequent start\/stop cycles in conveyor, compressor, and general machinery applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230312993051,"sku":"LC1E3210M5","price":42.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3210m5-440v-ac-contactor_14f29e42-5275-4564-a144-e497944fbac8.jpg?v=1777165943"},{"product_id":"schneider-electric-lc1e38004m7-easy-tesys-contactor-4p-50a","title":"Schneider Electric LC1E38004M7 Easy TeSys Contactor 4P 4NO AC-1 50 A 220 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E38004M7 is a 4-pole Easy TeSys contactor rated 50 A AC-1 for resistive-load switching at up to 440 V. It carries a 220 V AC 50\/60 Hz coil with built-in 4NO auxiliary contacts, power and control connections by screw clamp terminals in a 56 mm wide DIN-rail housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E38004M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P, 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at ≤440 V AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uc] Control Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Breaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 A at 440 V (IEC 60947)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 A, 10 s at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A gG at ≤690 V, coordination type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cycles\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Mcycles mechanical, 0.35 Mcycles electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Ambient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight x Width x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 56 x 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBeing AC-1 rated, the LC1E38004M7's 50 A figure applies to resistive loads, not motor starting current, and it shares its 56 mm frame and 64x93 mm footprint with the 40 A AC-1 variant despite the higher current. Four normally-open poles switch a full heating-load circuit in one device; where a motor contactor is needed, the 3-pole AC-3 Easy TeSys range is the correct choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230313156891,"sku":"LC1E38004M7","price":56.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e38004m7-easy-tesys-contactor-4p-50a.jpg?v=1790900918"},{"product_id":"schneider-electric-lc1e3801bd-easy-tesys-38a-contactor","title":"Schneider Electric LC1E3801BD Easy TeSys Control LC1E 38A 3P 400V 18.5kW Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3801BD is a 3-pole Easy TeSys Control contactor rated 38 A (AC-3) at up to 440 V AC, built for direct-on-line motor control up to 18.5 kW at 400 V. It carries a 24 V DC coil and one NC auxiliary contact, making it a compact DIN-rail or plate-mount switching device for control panels and motor starter combinations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3801BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 A \/ 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e494 A at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 cyc\/h at 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate \/ DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 56 x 99 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 38 A AC-3 rating supports direct-on-line starting of motors up to 18.5 kW at 400 V AC, a step up from the lower-current members of this frame while sharing the same 85 x 56 x 99 mm housing. The single NC auxiliary contact provides one spare normally-closed signal, suited to an interlock or fault-monitoring circuit that must open when the contactor picks up, rather than a running indication. A 24 V DC coil keeps the control circuit on low-voltage DC rather than a mains-referenced AC coil. The 310 A \/ 10 s short-time withstand current gives margin to ride through inrush conditions under coordinated fuse protection (63 A gG, type 1).\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230313419035,"sku":"LC1E3801BD","price":61.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3801bd-easy-tesys-contactor.jpg?v=1790287371"},{"product_id":"schneider-lc1e3801m5-easy-tesys-38a-3p-contactor","title":"Schneider Electric LC1E3801M5 Easy TeSys 3-Pole 38A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3801M5 is an Easy TeSys series 3-pole AC contactor rated at 38A and 440V, designed for motor control and industrial load switching applications. This power contactor delivers dependable performance in AC-3 and AC-1 utilization categories, making it a trusted choice for engineers and panel builders requiring compact, robust switching in automation and motor starter assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3801M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line motor starters controlling three-phase induction motors up to 38A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for use in control panels, machine tools, conveyors, pumps, and HVAC systems requiring reliable power switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Compatible with thermal overload relays for complete motor protection starter combinations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Switching Loads:\u003c\/strong\u003e Handles resistive and inductive AC-1 and AC-3 load switching in commercial and industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230313484571,"sku":"LC1E3801M5","price":51.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3801m5-440v-ac-contactor_bdbdaec3-fc04-43e2-8345-09eebfe3024e.jpg?v=1777165947"},{"product_id":"schneider-lc1e3810b5-easy-tesys-38a-3pole-contactor","title":"Schneider Electric LC1E3810B5 Easy TeSys 3-Pole 38A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3810B5 is a 3-pole 38A AC contactor from the Easy TeSys series, designed for motor switching and industrial power control applications up to 440V. This compact power contactor delivers dependable performance in motor starter circuits, offering a robust 38A rated current capacity suitable for AC-3 utilisation category duties. Weighing just 1.3 kg, the LC1E3810B5 fits neatly into control panels where space and reliability are critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3810B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for direct-on-line and reversing motor starter circuits in industrial machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for switching resistive and inductive loads in AC-3 and AC-1 utilisation categories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Designed for integration into MCC (Motor Control Centre) panels and switchgear assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Commonly used in compressor and fan motor control across commercial and industrial HVAC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumping Stations:\u003c\/strong\u003e Reliable contactor solution for pump motor management in water treatment and industrial process plants.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230313648411,"sku":"LC1E3810B5","price":51.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3810b5-440v-ac-contactor_c0e9694b-baa5-4ed6-8ef3-41e158b7c78f.jpg?v=1777165952"},{"product_id":"schneider-lc1e3810m5-easypact-tvs-38a-3p-440v-contactor","title":"Schneider Electric LC1E3810M5 EasyPact TVS 3P 38A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E3810M5 is a 3-pole 38A AC contactor from the EasyPact TVS series, designed for motor switching and power control applications up to 440V. Built for reliable industrial operation, the LC1E3810M5 delivers robust performance in demanding environments where dependable motor starter contactor functionality is essential. Weighing 9.1 kg, this power contactor is engineered to meet the requirements of automation and motor control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E3810M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for starting and stopping three-phase induction motors in AC-3 duty cycles across industrial machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Suited for integration into MCC (Motor Control Centre) assemblies and distribution boards requiring reliable switching up to 440V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Control:\u003c\/strong\u003e Frequently deployed in HVAC systems, water treatment plants, and compressor stations where dependable AC contactor operation is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Material Handling:\u003c\/strong\u003e Used in conveyor drive systems and packaging machinery requiring robust motor starter contactor performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Compatible with PLC-driven control circuits for automated production lines requiring frequent switching operations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated current of the LC1E3810M5?\u003c\/strong\u003e The LC1E3810M5 is rated at 38A, making it suitable for controlling motors in the medium power range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage is this contactor rated for?\u003c\/strong\u003e This EasyPact TVS contactor is rated for 440V AC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many poles does the LC1E3810M5 have?\u003c\/strong\u003e It is a 3-pole (3P) contactor, designed for three-phase motor and power switching applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich series does the LC1E3810M5 belong to?\u003c\/strong\u003e It belongs to the Schneider Electric EasyPact TVS series, known for ease of installation and reliable industrial performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230313746715,"sku":"LC1E3810M5","price":51.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e3810m5-440v-ac-contactor_498d96b8-cb8f-475f-8a80-9c45041df279.jpg?v=1777165956"},{"product_id":"schneider-electric-lc1e40004m7-contactor","title":"Schneider Electric LC1E40004M7 Easy TeSys Contactor 4P 4NO AC-1 60 A 220 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E40004M7 is a 4-pole Easy TeSys contactor rated 60 A AC-1 (up to 440 V) for resistive and non-motor switching duty, with a rated breaking capacity of 320 A at 440 V. It carries a 220 V AC coil, no built-in auxiliary contact, and screw clamp terminals on the power circuit for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E40004M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A - 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C (Uc) \/ -5...55 °C (operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127 x 85 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRated strictly for AC-1 resistive duty, it is not sized for direct motor starting at this current; pick the equivalent AC-3 TeSys Deca frame for motor loads. It ships without a built-in auxiliary contact, so add a separate auxiliary contact block where interlock or run-feedback signalling is required. The 320 A breaking capacity at 440 V sets the ceiling for downstream short-circuit protection coordination.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230314434843,"sku":"LC1E40004M7","price":87.87,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e40004m7-contactor.jpg?v=1790901053"},{"product_id":"schneider-lc1e400m7-tesyns-e-400a-3p-contactor","title":"Schneider Electric LC1E400M7 TeSys E 3-Pole 400A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E400M7 is a TeSys E series 3-pole AC contactor rated at 400A and 440V, engineered for heavy-duty motor control and industrial power switching applications. Designed for demanding environments, the LC1E400M7 delivers reliable performance in AC-3 and AC-1 utilization categories, making it a trusted choice for motor starter panels, distribution boards, and large-load switching circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E400M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.98 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for starting and stopping large three-phase AC motors in industrial facilities, pump stations, and compressor rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Suitable for switching heavy resistive and inductive loads in main distribution panels and MCC (Motor Control Centre) assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Used in large air-handling units, chillers, and industrial cooling systems requiring reliable high-current switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industry:\u003c\/strong\u003e Applied in manufacturing lines, conveyors, and heavy machinery where consistent motor control is critical to production uptime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenewable Energy \u0026amp; Utilities:\u003c\/strong\u003e Compatible with generator control panels and capacitor bank switching in power factor correction systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230314598683,"sku":"LC1E400M7","price":853.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e400m7-440v-ac-contactor_50767ab5-6420-4877-8593-35914bdaa2c6.jpg?v=1777165961"},{"product_id":"schneider-lc1e40b5-easypact-tvs-40a-3p-contactor","title":"Schneider Electric LC1E40B5 EasyPact TVS 3-Pole 40A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E40B5 is an EasyPact TVS series 3-pole AC contactor rated at 40A and 440V, designed for reliable motor switching and power control in industrial applications. Part of Schneider's proven EasyPact TVS range, the LC1E40B5 delivers robust performance for AC-3 motor loads and AC-1 resistive loads, making it a go-to solution for OEMs, panel builders, and industrial automation engineers.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E40B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyPact TVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.98 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Switching:\u003c\/strong\u003e Ideal for starting and stopping AC induction motors in pumps, fans, compressors, and conveyors under AC-3 utilization category.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Panels:\u003c\/strong\u003e Suitable for integration into MCC (Motor Control Centers) and industrial control panels requiring reliable 40A switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Commonly deployed in air handling units and chiller control panels for cyclic switching of motor loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e A preferred contactor for machine builders requiring a compact, cost-effective, and reliable switching device compatible with Schneider's EasyPact ecosystem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Works alongside thermal overload relays and manual motor starters for comprehensive motor protection and control solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230314762523,"sku":"LC1E40B5","price":59.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e40b5-440v-ac-contactor_8f5e54c2-b42c-4f24-bcf0-7480a47faaa8.jpg?v=1777165965"},{"product_id":"schneider-lc1e40m5-easy-tesys-40a-3p-contactor","title":"Schneider Electric LC1E40M5 Easy TeSys 3-Pole 40A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E40M5 is a 3-pole 40A Easy TeSys series AC contactor rated at 440V, designed for efficient motor starting, stopping, and reversing in industrial control applications. Part of Schneider's proven Easy TeSys family, the LC1E40M5 delivers dependable power switching for AC-3 motor loads and AC-1 resistive loads across a broad range of industrial environments. Weighing 11.35 kg, this contactor offers robust construction suited to demanding panel-build and OEM applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E40M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Ideal for AC-3 duty — starting and switching three-phase induction motors in pumps, fans, compressors, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switching:\u003c\/strong\u003e Suitable for AC-1 resistive and slightly inductive load switching in industrial panels and machine automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Panel Building:\u003c\/strong\u003e Compact Easy TeSys form factor simplifies integration into motor control centres (MCCs) and control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Services \u0026amp; HVAC:\u003c\/strong\u003e Used for HVAC fan and pump motor control in commercial and industrial building management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Industrial Automation:\u003c\/strong\u003e Compatible with programmable logic controllers (PLCs) and motor starter assemblies requiring reliable electromagnetic switching.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230314828059,"sku":"LC1E40M5","price":59.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e40m5-440v-ac-contactor_eb77d617-9f0f-4472-9e4a-b876340e80fa.jpg?v=1777165970"},{"product_id":"schneider-electric-lc1e500m7-easy-tesys-500a-contactor","title":"Schneider Electric LC1E500M7 Easy TeSys Control LC1E 500A 3P 400V 250kW Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E500M7 is a 3-pole Easy TeSys Control contactor rated 500 A (AC-3) at up to 440 V AC, built for direct-on-line motor control up to 250 kW at 400 V. It carries a 220 V AC coil and no built-in auxiliary contact, making it a bar-terminal power contactor for plate-mounted motor starter and switching panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E500M7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie) AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A at \u0026lt;=440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW at 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4200 A \/ 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 A at 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2400 cyc\/h at 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5...55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 233 x 232 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 500 A AC-3 rating supports direct-on-line starting of motors up to 250 kW at 400 V AC, while the separate 700 A AC-1 rating applies to resistive loads, not motor circuits. Bar terminals with a 40 x 5 mm busbar cross-section and a 35 N.m power-circuit tightening torque reflect the bolted, high-current connections this frame size needs, in place of the screw-clamp terminals used on lower-current contactors in the range. The 4200 A \/ 10 s short-time withstand current gives margin to hold through fault current until the 800 A gG upstream fuses clear. With no built-in auxiliary contact, an add-on auxiliary contact block is required for any status or interlock signal.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230315221275,"sku":"LC1E500M7","price":1318.83,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e500m7-easy-tesys-contactor.jpg?v=1790287377"},{"product_id":"schneider-electric-lc1e50b5-contactor","title":"Schneider Electric LC1E50B5 Easy TeSys Contactor 3P 3NO AC-3 50 A 24 V AC Coil Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E50B5 is a 3-pole Easy TeSys contactor rated 50 A AC-3 (up to 440 V) for direct-on-line motor control, switching motors up to 22 kW at 400 V. It carries a 24 V AC coil, no built-in auxiliary contact, and screw clamp terminals on both power and control circuits for DIN-rail or plate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E50B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePole contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-3 \/ AC-3e \/ AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational current (Ie), AC-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eundefined A at ≤ 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 690 V AC 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor power at 400 V (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl circuit voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary contact composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConventional free air thermal current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e425 A at 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-time withstand current (Icw)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A - 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated fuse rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A gG (coordination type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eplate \/ DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum operating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible ambient air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C (Uc) \/ -5...55 °C (operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127 x 75 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.98 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCB Scheme\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 50 A AC-3 it covers motors up to 22 kW at 400 V; The coil voltage is chosen to match the panel control-circuit supply. The mirror-contact-certified 1 NO + 1 NC auxiliary block confirms power-contact position for safety-circuit feedback without an external contact block.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230315516187,"sku":"LC1E50B5","price":70.46,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e50b5-contactor.jpg?v=1790901062"},{"product_id":"schneider-lc1e50m5-easy-tesys-50a-3pole-contactor","title":"Schneider Electric LC1E50M5 Easy TeSys 3-Pole 50A 440V AC Contactor","description":"\u003cp\u003eThe Schneider Electric LC1E50M5 is an Easy TeSys series 3-pole AC contactor rated at 50A and 440V, designed for motor switching and industrial power control applications. Part of the proven LC1E family, this contactor delivers dependable performance in AC-3 and AC-1 utilization categories, making it a go-to solution for motor starter panels and automation control systems. Weighing 18.6 kg, the LC1E50M5 is built for robust, continuous-duty industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E50M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starting \u0026amp; Control:\u003c\/strong\u003e Ideal for direct-on-line (DOL) motor starters in AC-3 utilization category for squirrel-cage motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation Panels:\u003c\/strong\u003e Suitable for integration into MCC (Motor Control Centre) panels and PLC-controlled systems requiring reliable switching of inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pump Systems:\u003c\/strong\u003e Commonly deployed for switching compressors, pumps, fans, and other motor-driven equipment in building services and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistive Load Switching:\u003c\/strong\u003e Applicable in AC-1 duty for resistive and slightly inductive loads such as heating elements and lighting banks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat utilization categories does the LC1E50M5 support?\u003c\/strong\u003e The LC1E50M5 is designed for AC-3 (motor starting\/switching) and AC-1 (resistive\/low-inductive loads) utilization categories per IEC standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this contactor compatible with auxiliary contact blocks?\u003c\/strong\u003e Yes, the Easy TeSys LC1E range supports add-on auxiliary contact blocks for signalling and interlocking functions, consistent with the LC1E series architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the series for this contactor?\u003c\/strong\u003e This unit belongs to the Schneider Electric Easy TeSys series, the LC1E model line, widely used across industrial and commercial electrical installations worldwide.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230315811099,"sku":"LC1E50M5","price":81.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lc1e50m5-440v-ac-contactor_72754ec8-73fe-49d7-ac4f-43bc8019d568.jpg?v=1777165975"}],"url":"https:\/\/stoklink.com\/collections\/schneider-easy-tesys.oembed?page=4","provider":"Stoklink","version":"1.0","type":"link"}