{"title":"Schneider ComPacT NSX MCCBs","description":"\u003cp\u003eSchneider Electric ComPacT NSX MCCBs are molded case circuit breakers for 12.5 A to 630 A distribution and motor circuits. The range covers 1 to 4 poles across NSX100, NSX250, NSX400 and NSX630 frames, with more than 350 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNSX100 and NSX250 frames with TM-D thermal-magnetic trip units.\u003c\/li\u003e\n\u003cli\u003eNSX400 and NSX630 frames with MicroLogic electronic trip units.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity classes from F up to R, with up to 200 kA on NSX630R.\u003c\/li\u003e\n\u003cli\u003eSpare parts: \u003ca href=\"\/collections\/mccb-accessories\"\u003eMCCB Accessories, Releases \u0026amp; Trip Units\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFrame size sets the current range. Pick the smallest frame that carries the load.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity class (F, N, H, S, L, R) must exceed the fault level.\u003c\/li\u003e\n\u003cli\u003ePick TM-D for simple feeders and MicroLogic for adjustable protection and measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does the letter in NSX250H mean?\u003c\/h3\u003e\u003cp\u003eIt is the breaking capacity class. Letters rise in breaking capacity, and the title lists the kA figure for the exact part.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between TM-D and MicroLogic?\u003c\/h3\u003e\u003cp\u003eTM-D is a thermal-magnetic trip unit. MicroLogic is an electronic trip unit with adjustable protection settings.\u003c\/p\u003e\u003ch3\u003eCan you export ComPacT NSX breakers?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-c10f4tm080d1-nsx80-dc-pv-mccb","title":"Schneider Electric C10F4TM080D1 ComPacT NSX80 DC PV 4P 80 A 10 kA DC TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F4TM080D1 is a 4P, 80 A ComPacT NSX80 DC PV moulded case circuit breaker purpose-built for photovoltaic DC distribution. Its TM-DC thermal-magnetic trip unit delivers 10 kA breaking capacity at 1000 V DC (4 poles in series), and it mounts on a fixed backplate rated to the same 1000 V DC insulation level as its operating voltage.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F4TM080D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX80 DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e80 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC (4 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-DC (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003e[Ir] adjustable 0.7...1x In; [Ii] fixed 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe C10F4TM080D1 is the DC PV variant of the ComPacT NSX80 range, built for photovoltaic string and combiner-box circuits rather than the AC distribution F\/N\/H frame ladder used elsewhere in ComPacT NSX100. With all four poles connected in series for the DC circuit, this C10F4TM080D1 variant's 10 kA breaking capacity applies to the full pole group, not per pole — a detail that matters when sizing the upstream combiner-box protection on a photovoltaic string.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229505622299,"sku":"C10F4TM080D1","price":444.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f4tm080d1-nsx80-dc-pv-mccb.jpg?v=1790868663"},{"product_id":"schneider-electric-c16f4tm125d1-nsx125-dc-pv-mccb","title":"Schneider Electric C16F4TM125D1 ComPacT NSX125 DC PV 4P 125 A 10 kA DC TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C16F4TM125D1 is a 4-pole Schneider Electric ComPacT NSX125 DC PV moulded case circuit breaker rated 125 A at 40 °C, built for 1000 V DC photovoltaic circuits with a TM-DC thermal-magnetic trip unit and a DC breaking capacity (Icu) of 10 kA with all four poles connected in series, at a net weight of 2.8 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC16F4TM125D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX125 DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotovoltaic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC, 4 poles in series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (thermal-magnetic, DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A, fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside, front downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe C16F4TM125D1's 10 kA DC Icu is rated specifically for 4 poles in series at the full 1000 V DC — a figure that is not directly comparable to an AC breaker's kA rating because interrupting a sustained DC arc needs more series poles and contact gap than clearing an AC zero-crossing. The 0.7...1 x In adjustable thermal setting lets the trip point be tuned below the 125 A frame rating to match the PV string's rated short-circuit current. For higher string currents, the 160 A TM-DC variant shares the same 140 x 161 x 86 mm frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229507031323,"sku":"C16F4TM125D1","price":495.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c16f4tm125d1-nsx125-dc-pv-mccb.jpg?v=1790869623"},{"product_id":"schneider-electric-c16f4tm160d1-nsx160-dc-pv-mccb","title":"Schneider Electric C16F4TM160D1 ComPacT NSX160 DC PV 4P 160 A 10 kA DC TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C16F4TM160D1 is a 4-pole Schneider Electric ComPacT NSX160 DC PV moulded case circuit breaker rated 160 A at 40 °C, built for 1000 V DC photovoltaic circuits with a TM-DC thermal-magnetic trip unit and a DC breaking capacity (Icu) of 10 kA with all four poles connected in series, at a net weight of 2.8 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC16F4TM160D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX160 DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotovoltaic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC, 4 poles in series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (thermal-magnetic, DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A, fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside, front downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 160 A the C16F4TM160D1 covers the higher end of string or combiner-box current in this DC PV frame, sharing the identical 140 x 161 x 86 mm body, 10 kA DC Icu and 1250 A fixed instantaneous pickup with the 125 A variant. The 0.7...1 x In adjustable thermal range lets the setting be dropped below 160 A if the array's actual short-circuit current is lower, without moving to the smaller-frame 125 A unit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eString or sub-array protection on 1000 V DC photovoltaic installations, ahead of the inverter DC input, where the breaker must clear DC fault current rather than only isolate it.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229507096859,"sku":"C16F4TM160D1","price":558.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c16f4tm160d1-nsx160-dc-pv-mccb.jpg?v=1790869631"},{"product_id":"schneider-electric-c25f4tm200d1-nsx200-dc-pv-mccb","title":"Schneider Electric C25F4TM200D1 ComPacT NSX200 DC PV 4P 200 A 10 kA DC TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C25F4TM200D1 is a 4-pole Schneider Electric ComPacT NSX200 DC PV moulded case circuit breaker rated 200 A at 40 °C, built for 1000 V DC photovoltaic circuits with a TM-DC thermal-magnetic trip unit and a DC breaking capacity (Icu) of 10 kA with all four poles connected in series, at a net weight of 2.8 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC25F4TM200D1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX200 DC PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotovoltaic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icu] Breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC, 4 poles in series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ics] Service breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA at 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (thermal-magnetic, DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-time pick-up adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous pick-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...10 x In, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside, front downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the 125\/160 A NSX125\/160 DC PV breakers in this range, the C25F4TM200D1's instantaneous pickup is adjustable (5...10 x In) rather than fixed, giving finer tuning against the PV array's short-circuit current contribution, which is typically only slightly above rated current. The 200 A frame shares the same 10 kA DC Icu and 140 x 161 x 86 mm body as the smaller NSX125\/160 DC PV units, so the choice between them comes down to the string's rated current alone.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eString or sub-array protection on 1000 V DC photovoltaic installations, ahead of the inverter DC input, where the breaker must clear DC fault current rather than only isolate it.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229508440347,"sku":"C25F4TM200D1","price":642.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c25f4tm200d1-nsx200-dc-pv-mccb.jpg?v=1790869604"},{"product_id":"schneider-electric-c40f3tm250d-compact-nsx250f-dc-mccb","title":"Schneider Electric C40F3TM250D ComPacT NSX250F DC 3P 250 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F3TM250D is a 3-pole ComPacT NSX250F DC moulded case circuit breaker rated 250 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F3TM250D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX250F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 250 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229508636955,"sku":"C40F3TM250D","price":848.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f3tm250d.jpg?v=1790868808"},{"product_id":"schneider-electric-c40f3tm320d-compact-nsx320f-dc-mccb","title":"Schneider Electric C40F3TM320D ComPacT NSX320F DC 3P 320 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F3TM320D is a 3-pole ComPacT NSX320F DC moulded case circuit breaker rated 320 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F3TM320D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX320F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 320 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229508702491,"sku":"C40F3TM320D","price":848.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f3tm320d.jpg?v=1790868818"},{"product_id":"schneider-electric-c40f3tm400d-compact-nsx400f-dc-mccb","title":"Schneider Electric C40F3TM400D ComPacT NSX400F DC 3P 400 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F3TM400D is a 3-pole ComPacT NSX400F DC moulded case circuit breaker rated 400 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F3TM400D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 400 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229508800795,"sku":"C40F3TM400D","price":848.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f3tm400d.jpg?v=1790868827"},{"product_id":"schneider-electric-c40f4tm250d-compact-nsx250f-dc-mccb","title":"Schneider Electric C40F4TM250D ComPacT NSX250F DC 4P 250 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F4TM250D is a 4-pole ComPacT NSX250F DC moulded case circuit breaker rated 250 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F4TM250D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX250F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 250 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229508866331,"sku":"C40F4TM250D","price":1126.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f4tm250d.jpg?v=1790868835"},{"product_id":"schneider-electric-c40f4tm320d-compact-nsx320f-dc-mccb","title":"Schneider Electric C40F4TM320D ComPacT NSX320F DC 4P 320 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F4TM320D is a 4-pole ComPacT NSX320F DC moulded case circuit breaker rated 320 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F4TM320D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX320F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 320 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509062939,"sku":"C40F4TM320D","price":1126.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f4tm320d.jpg?v=1790868845"},{"product_id":"schneider-electric-c40f4tm400d-compact-nsx400f-dc-mccb","title":"Schneider Electric C40F4TM400D ComPacT NSX400F DC 4P 400 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C40F4TM400D is a 4-pole ComPacT NSX400F DC moulded case circuit breaker rated 400 A on a TM-DC thermal-magnetic trip unit for DC distribution. Breaking capacity (Icu) is 36 kA DC at 750 V DC across 3 poles in series, with both thermal overload and magnetic short-circuit pick-up adjustable on the trip unit.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40F4TM400D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series) (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Breaking Capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24...125 V DC, 36 kA at 250 V DC, 36 kA at 500 V DC, 36 kA at 750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC, thermal-magnetic, LI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] Long-Time Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7...1 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] Instantaneous Pick-up Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5...5 x In (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability For Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront (upside and downside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 x 255 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree Of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUnlike the AC TM-D trip unit, the TM-DC fits both the thermal overload (Ir, 0.7-1 x In) and the magnetic instantaneous pick-up (2.5-5 x In) with field adjustment, which matters on DC circuits where fault current does not fall to zero each half-cycle and the magnetic trip threshold needs tuning to the installation. The 750 V DC rating is reached with all 3 poles wired in series; pick the 400 A rating to match the DC bus or PV array current, and choose a different sibling in the same TM-DC series for a higher or lower current without changing the 36 kA breaking capacity.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509390619,"sku":"C40F4TM400D","price":1126.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40f4tm400d.jpg?v=1790868854"},{"product_id":"schneider-electric-c40s3tm250d","title":"Schneider Electric C40S3TM250D ComPacT NSX400S DC 3P 250 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S3TM250D is a Schneider Electric ComPacT NSX400S DC 3-pole DC moulded case circuit breaker rated 250 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S3TM250D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 250 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509685531,"sku":"C40S3TM250D","price":1035.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s3tm250d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868705"},{"product_id":"schneider-electric-c40s3tm320d","title":"Schneider Electric C40S3TM320D ComPacT NSX400S DC 3P 320 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S3TM320D is a Schneider Electric ComPacT NSX400S DC 3-pole DC moulded case circuit breaker rated 320 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S3TM320D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 320 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509751067,"sku":"C40S3TM320D","price":1035.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s3tm320d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868715"},{"product_id":"schneider-electric-c40s3tm400d","title":"Schneider Electric C40S3TM400D ComPacT NSX400S DC 3P 400 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S3TM400D is a Schneider Electric ComPacT NSX400S DC 3-pole DC moulded case circuit breaker rated 400 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S3TM400D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 400 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509816603,"sku":"C40S3TM400D","price":1035.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s3tm400d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868724"},{"product_id":"schneider-electric-c40s4tm250d","title":"Schneider Electric C40S4TM250D ComPacT NSX400S DC 4P 250 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S4TM250D is a Schneider Electric ComPacT NSX400S DC 4-pole DC moulded case circuit breaker rated 250 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S4TM250D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 250 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509914907,"sku":"C40S4TM250D","price":1443.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s4tm250d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868734"},{"product_id":"schneider-electric-c40s4tm320d","title":"Schneider Electric C40S4TM320D ComPacT NSX400S DC 4P 320 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S4TM320D is a Schneider Electric ComPacT NSX400S DC 4-pole DC moulded case circuit breaker rated 320 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S4TM320D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 320 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229509980443,"sku":"C40S4TM320D","price":1443.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s4tm320d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868743"},{"product_id":"schneider-electric-c40s4tm400d","title":"Schneider Electric C40S4TM400D ComPacT NSX400S DC 4P 400 A 100 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C40S4TM400D is a Schneider Electric ComPacT NSX400S DC 4-pole DC moulded case circuit breaker rated 400 A at 40 °C and 750 V DC, with a 100 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC40S4TM400D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX400S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 100 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 100 kA at 750 V DC. Choose the 400 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510045979,"sku":"C40S4TM400D","price":1443.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c40s4tm400d-nsx400s-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868753"},{"product_id":"schneider-electric-c63f3tm500d","title":"Schneider Electric C63F3TM500D ComPacT NSX630F DC 3P 500 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C63F3TM500D is a Schneider Electric ComPacT NSX630F DC 3-pole DC moulded case circuit breaker rated 500 A at 40 °C and 750 V DC, with a 36 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63F3TM500D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 36 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 36 kA at 750 V DC. Choose the 500 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510373659,"sku":"C63F3TM500D","price":1041.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63f3tm500d-nsx630f-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868723"},{"product_id":"schneider-electric-c63f3tm600d","title":"Schneider Electric C63F3TM600D ComPacT NSX630F DC 3P 600 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C63F3TM600D is a Schneider Electric ComPacT NSX630F DC 3-pole DC moulded case circuit breaker rated 600 A at 40 °C and 750 V DC, with a 36 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63F3TM600D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 36 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 36 kA at 750 V DC. Choose the 600 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510439195,"sku":"C63F3TM600D","price":1095.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63f3tm600d-nsx630f-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868732"},{"product_id":"schneider-electric-c63f4tm500d","title":"Schneider Electric C63F4TM500D ComPacT NSX630F DC 4P 500 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C63F4TM500D is a Schneider Electric ComPacT NSX630F DC 4-pole DC moulded case circuit breaker rated 500 A at 40 °C and 750 V DC, with a 36 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63F4TM500D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 36 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 36 kA at 750 V DC. Choose the 500 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510504731,"sku":"C63F4TM500D","price":1398.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63f4tm500d-nsx630f-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868741"},{"product_id":"schneider-electric-c63f4tm600d","title":"Schneider Electric C63F4TM600D ComPacT NSX630F DC 4P 600 A 36 kA TM-DC Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe C63F4TM600D is a Schneider Electric ComPacT NSX630F DC 4-pole DC moulded case circuit breaker rated 600 A at 40 °C and 750 V DC, with a 36 kA breaking capacity (Icu) across the full DC voltage range. Its TM-DC thermal-magnetic trip unit gives adjustable overload and short-circuit protection without electronic components.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63F4TM600D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630F DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA at 24…125 V DC (1 pole), 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series), 36 kA at 750 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr (overload, adjustable) 0.7–1×In; Ii (short-circuit, adjustable) 2.5–5×In.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle handle, fixed mounting on backplate, front\/front connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 255 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC trip unit gives adjustable overload protection (Ir 0.7–1×In) and adjustable magnetic short-circuit protection (Ii 2.5–5×In) without electronic components, which keeps the device simple for DC distribution or photovoltaic combiner applications. The 36 kA breaking capacity stays constant from 24 V DC up to 750 V DC because the poles connect in series for the higher-voltage ratings — the series 3-pole connection is what delivers the full 36 kA at 750 V DC. Choose the 600 A rating over the other TM-DC variants in the same frame to match the DC feeder or string combiner current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510799643,"sku":"C63F4TM600D","price":1676.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63f4tm600d-nsx630f-dc-dc-moulded-case-circuit-breaker.jpg?v=1790868751"},{"product_id":"schneider-electric-c63s3tm500d-nsx-dc-mccb","title":"Schneider Electric C63S3TM500D ComPacT NSX500S DC 3P 500 A 100 kA TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C63S3TM500D is a three-pole ComPacT NSX630S DC moulded case circuit breaker rated 500 A at 40 °C and 750 V DC, with a 100 kA breaking capacity across 24 V DC to 750 V DC using one to three poles in series. It carries a TM-DC thermal-magnetic trip unit for adjustable overload and magnetic short-circuit protection, fixed for backplate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63S3TM500D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3D protected poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series), conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEqual to Icu (100%) at every listed voltage tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic, LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7…1 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] instantaneous pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5…5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm x 255 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC thermal-magnetic trip unit gives an adjustable 0.7…1 x In overload setting and a 2.5…5 x In magnetic trip, sized for DC distribution and DC motor circuits up to 750 V DC using poles in series. Choose the 600 A rating from this frame when the circuit's continuous current falls outside the 500 A adjustment band, and move to the 4-pole version instead when the installation does or does not need a switched neutral conductor.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229510930715,"sku":"C63S3TM500D","price":1335.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63s3tm500d-nsx-dc-mccb.jpg?v=1790869196"},{"product_id":"schneider-electric-c63s4tm500d-nsx-dc-mccb","title":"Schneider Electric C63S4TM500D ComPacT NSX500S DC 4P 500 A 100 kA TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C63S4TM500D is a four-pole ComPacT NSX630S DC moulded case circuit breaker rated 500 A at 40 °C and 750 V DC, with a 100 kA breaking capacity across 24 V DC to 750 V DC using one to three poles in series. It carries a TM-DC thermal-magnetic trip unit for adjustable overload and magnetic short-circuit protection, fixed for backplate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63S4TM500D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series), conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEqual to Icu (100%) at every listed voltage tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic, LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7…1 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] instantaneous pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5…5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm x 255 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC thermal-magnetic trip unit gives an adjustable 0.7…1 x In overload setting and a 2.5…5 x In magnetic trip, sized for DC distribution and DC motor circuits up to 750 V DC using poles in series. Choose the 600 A rating from this frame when the circuit's continuous current falls outside the 500 A adjustment band, and move to the 3-pole version instead when the installation does or does not need a switched neutral conductor.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229511029019,"sku":"C63S4TM500D","price":1792.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63s4tm500d-nsx-dc-mccb.jpg?v=1790869206"},{"product_id":"schneider-electric-c63s4tm600d-nsx-dc-mccb","title":"Schneider Electric C63S4TM600D ComPacT NSX600S DC 4P 600 A 100 kA TM-DC Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C63S4TM600D is a four-pole ComPacT NSX630S DC moulded case circuit breaker rated 600 A at 40 °C and 750 V DC, with a 100 kA breaking capacity across 24 V DC to 750 V DC using one to three poles in series. It carries a TM-DC thermal-magnetic trip unit for adjustable overload and magnetic short-circuit protection, fixed for backplate mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC63S4TM600D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX630S DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P (4D protected poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 24…125 V DC (1 pole), 100 kA at 250 V DC (1 pole), 100 kA at 500 V DC (2 poles in series), 100 kA at 750 V DC (3 poles in series), conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEqual to Icu (100%) at every listed voltage tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-DC (Thermal-magnetic, LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ir] long-time pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7…1 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ii] instantaneous pick-up adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5…5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm x 255 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation \/ storage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C \/ -50…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-DC thermal-magnetic trip unit gives an adjustable 0.7…1 x In overload setting and a 2.5…5 x In magnetic trip, sized for DC distribution and DC motor circuits up to 750 V DC using poles in series. Choose the 500 A rating from this frame when the circuit's continuous current falls outside the 600 A adjustment band, and move to the 3-pole version instead when the installation does or does not need a switched neutral conductor.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229511749915,"sku":"C63S4TM600D","price":1970.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c63s4tm600d-nsx-dc-mccb.jpg?v=1790869215"},{"product_id":"schneider-electric-c10f1tm016-nsx100f-16a-mccb","title":"Schneider Electric C10F1TM016 ComPacT NSX100F 1P 16 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F1TM016 is a 1P ComPacT NSX100F moulded case circuit breaker rated 16 A, dual-rated for AC (277 V) and DC (250 V) circuits, with an 18 kA breaking capacity (Icu) at 240 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F1TM016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e1P \/ 1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e277 V AC 50\/60 Hz, 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e18 kA at 220\/240 V AC, 36 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e190 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e35 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 190 A, so the 16 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. Use the 1-pole version on a single AC line-to-neutral or two-wire DC circuit; it is not a substitute for a 2-pole device on a two-wire ungrounded or floating AC circuit. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 250 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229586821403,"sku":"C10F1TM016","price":101.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f1tm016-nsx100f-mccb.jpg?v=1790868164"},{"product_id":"schneider-electric-c10f1tm020-nsx100f-20a-mccb","title":"Schneider Electric C10F1TM020 ComPacT NSX100F 1P 20 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F1TM020 is a 1P ComPacT NSX100F moulded case circuit breaker rated 20 A, dual-rated for AC (277 V) and DC (250 V) circuits, with an 18 kA breaking capacity (Icu) at 240 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F1TM020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e1P \/ 1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e20 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e277 V AC 50\/60 Hz, 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e18 kA at 220\/240 V AC, 36 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e190 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e35 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 190 A, so the 20 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. Use the 1-pole version on a single AC line-to-neutral or two-wire DC circuit; it is not a substitute for a 2-pole device on a two-wire ungrounded or floating AC circuit. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 250 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229586952475,"sku":"C10F1TM020","price":101.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f1tm020-nsx100f-mccb.jpg?v=1790868182"},{"product_id":"schneider-electric-c10f1tm100-nsx100f-100a-mccb","title":"Schneider Electric C10F1TM100 ComPacT NSX100F 1P 100 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F1TM100 is a 1P ComPacT NSX100F moulded case circuit breaker rated 100 A, dual-rated for AC (277 V) and DC (250 V) circuits, with an 18 kA breaking capacity (Icu) at 240 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F1TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e1P \/ 1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e277 V AC 50\/60 Hz, 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e18 kA at 220\/240 V AC, 36 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e800 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e35 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 800 A, so the 100 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. Use the 1-pole version on a single AC line-to-neutral or two-wire DC circuit; it is not a substitute for a 2-pole device on a two-wire ungrounded or floating AC circuit. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 250 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587149083,"sku":"C10F1TM100","price":118.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f1tm100-nsx100f-mccb.jpg?v=1790868197"},{"product_id":"schneider-electric-c10f2tm016-nsx100f-16a-mccb","title":"Schneider Electric C10F2TM016 ComPacT NSX100F 2P 16 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM016 is a 2P ComPacT NSX100F moulded case circuit breaker rated 16 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e16 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e190 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 190 A, so the 16 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587214619,"sku":"C10F2TM016","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm016-nsx100f-mccb.jpg?v=1790868211"},{"product_id":"schneider-electric-c10f2tm025-nsx100f-25a-mccb","title":"Schneider Electric C10F2TM025 ComPacT NSX100F 2P 25 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM025 is a 2P ComPacT NSX100F moulded case circuit breaker rated 25 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e300 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 300 A, so the 25 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587280155,"sku":"C10F2TM025","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm025-nsx100f-mccb.jpg?v=1790868228"},{"product_id":"schneider-electric-c10f2tm030-nsx100f-30a-mccb","title":"Schneider Electric C10F2TM030 ComPacT NSX100F 2P 30 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM030 is a 2P ComPacT NSX100F moulded case circuit breaker rated 30 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e30 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e300 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 300 A, so the 30 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587476763,"sku":"C10F2TM030","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm030-nsx100f-mccb.jpg?v=1790868243"},{"product_id":"schneider-electric-c10f2tm040-nsx100f-40a-mccb","title":"Schneider Electric C10F2TM040 ComPacT NSX100F 2P 40 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM040 is a 2P ComPacT NSX100F moulded case circuit breaker rated 40 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e500 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 500 A, so the 40 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587542299,"sku":"C10F2TM040","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm040-nsx100f-mccb.jpg?v=1790868251"},{"product_id":"schneider-electric-c10f2tm050-nsx100f-50a-mccb","title":"Schneider Electric C10F2TM050 ComPacT NSX100F 2P 50 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM050 is a 2P ComPacT NSX100F moulded case circuit breaker rated 50 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e50 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e500 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 500 A, so the 50 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587640603,"sku":"C10F2TM050","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm050-nsx100f-mccb.jpg?v=1790868260"},{"product_id":"schneider-electric-c10f2tm063-nsx100f-63a-mccb","title":"Schneider Electric C10F2TM063 ComPacT NSX100F 2P 63 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM063 is a 2P ComPacT NSX100F moulded case circuit breaker rated 63 A, dual-rated for AC (690 V) and DC (500 V) circuits, with an 18 kA breaking capacity (Icu) at 415 V AC. It uses a fixed, non-adjustable TM-D thermal-magnetic trip unit, giving compact, low-maintenance overload and short-circuit protection in small-frame distribution and DC applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eC10F2TM063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name \/ device\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles \/ protected poles\u003c\/td\u003e\n\u003ctd\u003e2P \/ 2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e63 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC | DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz, 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icu] Breaking capacity\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC, 15 kA at 440 V AC, 10 kA at 500\/525 V AC, 5 kA at 660\/690 V AC, 36 kA at 250 V DC (1 pole), 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity code\u003c\/td\u003e\n\u003ctd\u003eF 18 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eCategory A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (Thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ir] Long-time pick-up\u003c\/td\u003e\n\u003ctd\u003e1 x In — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ii] Instantaneous pick-up\u003c\/td\u003e\n\u003ctd\u003e500 A — Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode \/ support\u003c\/td\u003e\n\u003ctd\u003eFixed, Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-D trip unit on this NSX100F frame is fixed rather than adjustable: L overload protection is set at 1 x In and I instantaneous protection trips at 500 A, so the 63 A rating itself is the only selection variable — pick it to sit just above the circuit's full-load current. The 2-pole version covers both single-phase line-to-line AC circuits and two-wire DC circuits where both conductors must be switched and protected together. Because the breaker is dual-rated for AC and DC, the same part also fits DC distribution and battery circuits up to 500 V DC, where the 18 kA AC Icu figure does not apply and the 36 kA DC rating governs instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587706139,"sku":"C10F2TM063","price":136.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm063-nsx100f-mccb.jpg?v=1790868275"},{"product_id":"schneider-electric-c10f2tm100-nsx100f-mccb","title":"Schneider Electric C10F2TM100 ComPacT NSX100F 2P 100 A 18 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F2TM100 is a 2P, 100 A ComPacT NSX100F moulded case circuit breaker fitted with a TM-D thermal-magnetic trip unit rated for 18 kA breaking capacity at 380\/415 V AC (1P). It carries a 690 V rated operational voltage and mounts on a fixed backplate, suited to distribution circuits sized to its 100 A nameplate rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F2TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC (1P), 5 kA at 660\/690 V AC; 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e36 kA at 220\/240 V AC, 18 kA at 380\/415 V AC (1P), 5 kA at 660\/690 V AC; 36 kA at 500 V DC (2 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003e[Ir] fixed at 1x In; [Ii] fixed 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe F frame sits at the entry tier of the ComPacT NSX100 breaking-capacity ladder (18 kA at 380\/415 V AC (1P)), below the N (50 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. The TM-D trip unit on this C10F2TM100 variant has its thermal pickup fixed at 1x In, so the 100 A rating is the circuit's protected current with no field adjustment; choose the adjacent current rating in the same F frame if the protected load differs from 100 A.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229587902747,"sku":"C10F2TM100","price":157.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f2tm100-nsx100f-mccb.jpg?v=1790868107"},{"product_id":"schneider-electric-c10f32d040-nsx100f-mccb","title":"Schneider Electric C10F32D040 ComPacT NSX100F 3P 40 A 36 kA MicroLogic 2.2 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F32D040 is a 3P, 40 A ComPacT NSX100F moulded case circuit breaker fitted with an electronic MicroLogic 2.2 trip unit, rated for 36 kA breaking capacity at 380\/415 V AC. Long-time pickup is adjustable from 18...40 A and short-time protection is fixed-delay, giving LSoI coordination on a 690 V rated operational voltage, fixed-mount device.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F32D040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e40 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 8 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 4 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.2 (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eLSoI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003e[Ir] adjustable 9 settings 18...40 A; [Isd] adjustable 9 settings 1.5...10x Ir; [Ii] fixed 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e105 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe F frame sits at the entry tier of the ComPacT NSX100 breaking-capacity ladder (36 kA at 380\/415 V AC), below the N (50 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. The electronic MicroLogic 2.2 trip unit gives this C10F32D040 variant adjustable long-time pickup (18...40 A) and adjustable short-time pickup (1.5...10x Ir of Ir) with a fixed instantaneous stage, so the same physical breaker can be re-tuned across its current band rather than swapped for a different TM-D rating when the protected circuit's load changes.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229588164891,"sku":"C10F32D040","price":276.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f32d040-nsx100f-mccb.jpg?v=1790868115"},{"product_id":"schneider-c10f32d100-nsx100f-3p-100a-36ka-mccb","title":"Schneider Electric C10F32D100 NSX100F 3P 100A 36kA Compact NSX Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F32D100 NSX100F is a 3-pole 100A moulded case circuit breaker (MCCB) from the Compact NSX series, delivering a breaking capacity of 36 kA at 415V AC for robust protection of industrial distribution boards and control panels. Rated at 415V AC and weighing 2.05 kg, the NSX100F is engineered for demanding industrial environments where reliable overcurrent and short-circuit protection is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F32D100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Distribution Panels:\u003c\/strong\u003e Provides short-circuit and overload protection in main and sub-distribution boards up to 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Branch Circuit Protection:\u003c\/strong\u003e Suitable for protecting motor feeders and associated control equipment in manufacturing facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial \u0026amp; Infrastructure Projects:\u003c\/strong\u003e Ideal for BMS panels, HVAC systems, and building services where 100A 3-pole protection is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact form factor fits standard DIN-rail and fixed-mount installations within automation and control panels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229588230427,"sku":"C10F32D100","price":295.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f32d100-case-circuit-breaker_70e33567-c603-419f-9193-0eec236a6316.jpg?v=1777164323"},{"product_id":"schneider-electric-c10f3ma013-nsx100f-mccb","title":"Schneider Electric C10F3MA013 ComPacT NSX100F 3P 12.5 A 36 kA MA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3MA013 is a 3P, 12.5 A ComPacT NSX100F moulded case circuit breaker built for motor protection, fitted with an MA magnetic-only trip unit delivering 36 kA breaking capacity at 380\/415 V AC. Short-circuit pickup is adjustable from 6...14x In, and the device carries a 690 V rated operational voltage on a fixed backplate mount.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F3MA013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e12.5 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 8 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 4 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eMA (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003eAdjustable 9 settings, 6...14x In (both Isd and Ii)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e105 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe F frame sits at the entry tier of the ComPacT NSX100 breaking-capacity ladder (36 kA at 380\/415 V AC), below the N (50 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. Because the MA trip unit has no thermal (overload) element, this C10F3MA013 variant is selected purely to match a motor's starting current at the magnetic pickup — adjustable 6...14x In — while overload protection is handled by a separate thermal relay or contactor-integrated device downstream; pick a sibling with a higher or lower 12.5 A rating to match the motor's locked-rotor current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229588853019,"sku":"C10F3MA013","price":172.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3ma013-nsx100f-mccb.jpg?v=1790868133"},{"product_id":"schneider-c10f3ma025-nsx100f-25a-3p-36ka-mccb","title":"Schneider Electric C10F3MA025 NSX100F 3P 25A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3MA025 is a Compact NSX100F 3-pole moulded case circuit breaker rated at 25A with a breaking capacity of 36 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial control panels, motor feeders, and distribution boards. Part of Schneider's renowned Compact NSX100F series, the C10F3MA025 delivers robust performance in demanding electrical installations where dependable fault interruption at low current ratings is essential. Weighing just 2.05 kg, this compact MCCB fits efficiently into space-constrained enclosures without compromising on protection capability.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3MA025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Distribution Boards:\u003c\/strong\u003e Provides overcurrent and short-circuit protection for outgoing feeder circuits in low-voltage distribution panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Feeder Protection:\u003c\/strong\u003e Suitable as a branch circuit protective device upstream of motor starters and contactors in industrial automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact form factor allows straightforward integration into DIN rail or fixed-mount switchgear assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial \u0026amp; Light Industrial Installations:\u003c\/strong\u003e Ideal for protecting cables and equipment in commercial buildings, manufacturing facilities, and process plants operating at 415V AC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229588918555,"sku":"C10F3MA025","price":183.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3ma025-case-circuit-breaker_09ac57bb-ec97-4689-9d04-1bf1571c1fdb.jpg?v=1777164327"},{"product_id":"schneider-c10f3ma050-nsx100f-3p-50a-36ka-mccb","title":"Schneider Electric C10F3MA050 NSX100F 3P 50A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3MA050 is a Compact NSX100F 3-pole moulded case circuit breaker rated at 50A with a 36 kA breaking capacity at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial control panels and power distribution systems. The NSX100F series is widely specified by electrical engineers for its robust construction, compact footprint, and high performance in demanding environments. Weighing just 2.05 kg, the C10F3MA050 offers an ideal balance of protection capability and ease of installation on DIN rail or direct mounting arrangements.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3MA050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides reliable overcurrent and short-circuit protection in motor control centres and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Systems:\u003c\/strong\u003e Suitable as a feeder or branch breaker in low-voltage switchgear assemblies operating at up to 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Compact form factor and high breaking capacity make the NSX100F ideal for OEM machine panel integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Services:\u003c\/strong\u003e Applied in commercial and industrial HVAC, pumping, and general services electrical infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589016859,"sku":"C10F3MA050","price":183.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3ma050-case-circuit-breaker_89c18426-cc0c-4781-a74c-b0b2e835097c.jpg?v=1777164332"},{"product_id":"schneider-electric-c10f3ma100-nsx100f-mccb","title":"Schneider Electric C10F3MA100 ComPacT NSX100F 3P 100 A 36 kA MA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3MA100 is a 3P, 100 A ComPacT NSX100F moulded case circuit breaker built for motor protection, fitted with an MA magnetic-only trip unit delivering 36 kA breaking capacity at 380\/415 V AC. Short-circuit pickup is adjustable from 6...14x In, and the device carries a 690 V rated operational voltage on a fixed backplate mount.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F3MA100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e100 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 8 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 4 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eMA (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003eAdjustable 9 settings, 6...14x In (both Isd and Ii)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e105 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe F frame sits at the entry tier of the ComPacT NSX100 breaking-capacity ladder (36 kA at 380\/415 V AC), below the N (50 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. Because the MA trip unit has no thermal (overload) element, this C10F3MA100 variant is selected purely to match a motor's starting current at the magnetic pickup — adjustable 6...14x In — while overload protection is handled by a separate thermal relay or contactor-integrated device downstream; pick a sibling with a higher or lower 100 A rating to match the motor's locked-rotor current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589082395,"sku":"C10F3MA100","price":172.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3ma100-nsx100f-mccb.jpg?v=1790868142"},{"product_id":"schneider-c10f3tm016-nsx100f-16a-3p-36ka-mccb","title":"Schneider Electric C10F3TM016 NSX100F 3P 16A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM016 is a Compact NSX100F series moulded case circuit breaker (MCCB) rated at 16A with a 36 kA breaking capacity at 415V AC. This 3-pole industrial circuit breaker delivers reliable overcurrent and short-circuit protection for distribution panels, motor feeders, and critical industrial installations where robust fault interruption performance is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Distribution Boards:\u003c\/strong\u003e Provides reliable short-circuit and overload protection in main and sub-distribution panels within factories and industrial facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Feeder Protection:\u003c\/strong\u003e Suitable as a feeder circuit breaker for protecting motor branch circuits in manufacturing and process automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Building Services:\u003c\/strong\u003e Ideal for protecting electrical installations in commercial buildings, data centres, and infrastructure projects where high breaking capacity is required at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact NSX100F form factor fits standard DIN rail and fixed-mount enclosures, simplifying integration into new and retrofit control panels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589147931,"sku":"C10F3TM016","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm016-case-circuit-breaker_77cbbb71-73f0-4ad8-af80-8f4618a08c16.jpg?v=1777164336"},{"product_id":"schneider-c10f3tm025-nsx100f-25a-3p-36ka-mccb","title":"Schneider Electric C10F3TM025 NSX100F 3P 25A 36kA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM025 is a ComPacT NSX100F series 3-pole moulded case circuit breaker (MCCB) rated at 25A with a breaking capacity of 36 kA at 415V AC. Designed for fixed mounting in industrial control panels and distribution boards, this circuit breaker delivers reliable overload and short-circuit protection for motor circuits, feeders, and power distribution applications requiring robust fault interruption performance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589213467,"sku":"C10F3TM025","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm025-case-circuit-breaker_127dd13e-ccf5-4053-b9aa-c804bf981eb1.jpg?v=1777164340"},{"product_id":"schneider-c10f3tm032-nsx100f-32a-3p-36ka-mccb","title":"Schneider Electric C10F3TM032 NSX100F 3P 32A 36kA 415V Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM032 is a ComPacT NSX100F molded case circuit breaker delivering 32A rated current across 3 poles with a 36 kA breaking capacity at 415V AC. Engineered for reliable overload and short-circuit protection in industrial power distribution panels, the NSX100F combines thermal-magnetic trip technology with a compact frame design suited for demanding applications. Weighing just 2.05 kg, this next-generation ComPacT NSX unit offers robust performance in a space-efficient footprint.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NSX (new generation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic (TM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Ideal for main and sub-distribution boards in manufacturing plants, commercial buildings, and infrastructure projects requiring reliable 3-phase protection at up to 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor \u0026amp; Load Feeder Protection:\u003c\/strong\u003e Provides overload and short-circuit protection for motor feeders and branch circuits where thermal-magnetic trip characteristics are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Boards \u0026amp; Switchgear:\u003c\/strong\u003e Compact NSX100F frame integrates seamlessly into MCC (motor control centre) and LV switchgear assemblies, optimising panel space without compromising on 36 kA fault clearance capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator \u0026amp; Transformer Protection:\u003c\/strong\u003e Suitable as an incoming circuit breaker for generator sets and downstream transformer feeders requiring high breaking capacity in a 3-pole configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589410075,"sku":"C10F3TM032","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm032-case-circuit-breaker_c1e8ea84-c706-481c-a1a9-e9a3cfe447a8.jpg?v=1777164344"},{"product_id":"schneider-c10f3tm040-nsx100f-40a-3p-36ka-mccb","title":"Schneider Electric C10F3TM040 NSX100F 3P 40A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM040 is a Compact NSX100F 3-pole moulded case circuit breaker rated at 40A with a breaking capacity of 36 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution and control panel applications. Part of the renowned Compact NSX100F series, this circuit breaker delivers robust performance in a compact form factor suited for demanding electrical environments. Weighing 2.05 kg, it is engineered for straightforward installation in switchboards and motor control centres.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Provides overcurrent and short-circuit protection in main and sub-distribution boards within factories, manufacturing plants, and process facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Suitable for protecting motor feeders and branch circuits in motor control centres (MCCs) and switchgear assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact footprint and 3-pole configuration make the NSX100F C10F3TM040 ideal for integration into industrial control panels where space efficiency is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial \u0026amp; Infrastructure Buildings:\u003c\/strong\u003e Applicable in large commercial buildings, data centres, and infrastructure projects requiring dependable 415V AC distribution protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589475611,"sku":"C10F3TM040","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm040-case-circuit-breaker_72a8a646-3627-4a97-a0cd-bcf45532d607.jpg?v=1777164348"},{"product_id":"schneider-c10f3tm050-nsx100f-50a-3p-36ka-mccb","title":"Schneider Electric C10F3TM050 NSX100F 3P 50A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM050 is a Compact NSX100F series 3-pole moulded case circuit breaker rated at 50A with a breaking capacity of 36 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution and control panel applications. This MCCB delivers robust performance in demanding environments, making it a trusted choice for engineers specifying protection devices for motor circuits, feeder protection, and main distribution boards. The C10F3TM050 combines compact dimensions with high breaking performance, ensuring safe and dependable operation across a wide range of industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Ideal for protecting motors and associated wiring in industrial automation and process control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeeder Protection:\u003c\/strong\u003e Suitable as a feeder circuit breaker in main and sub-distribution boards within commercial and industrial facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact NSX100F form factor fits standard DIN rail and fixed mounting arrangements in control enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Used in low-voltage switchgear assemblies for reliable short-circuit and overload protection at 415V AC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589541147,"sku":"C10F3TM050","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm050-case-circuit-breaker_6c8b0287-d928-403f-98fe-65d347b62436.jpg?v=1777164354"},{"product_id":"schneider-c10f3tm063-nsx100f-63a-3p-36ka-mccb","title":"Schneider Electric C10F3TM063 NSX100F 3P 63A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM063 is a Compact NSX100F series 3-pole moulded case circuit breaker (MCCB) rated at 63A with a breaking capacity of 36 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution panels. Built on the proven NSX100F platform, this circuit breaker delivers robust performance in demanding commercial and industrial environments where dependable fault interruption is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Overcurrent and short-circuit protection in main and sub-distribution boards across manufacturing facilities and process plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Panel board protection in offices, retail, and data centres where reliable fault interruption at 415V is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Upstream protection for motor starters, variable speed drives, and other motor control equipment up to 63A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Suitable for DIN rail or direct mounting in industrial control panels requiring a compact 3-pole MCCB footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator \u0026amp; Infrastructure Protection:\u003c\/strong\u003e Applied in generator switchgear and utility distribution where a 36 kA breaking capacity at 415V meets IEC fault-level requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589639451,"sku":"C10F3TM063","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm063-case-circuit-breaker_378e693b-4ded-4950-8cc2-a920c642f222.jpg?v=1777164358"},{"product_id":"schneider-c10f3tm080-nsx100f-80a-3p-36ka-mccb","title":"Schneider Electric C10F3TM080 NSX100F 3P 80A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM080 is a Compact NSX100F series 3-pole moulded case circuit breaker rated at 80A with a breaking capacity of 36 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution panels. The NSX100F platform delivers high performance in a compact form factor, making it well suited for motor protection, feeder protection, and main distribution board applications where space and reliability are equally critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Main and sub-distribution boards requiring robust short-circuit protection up to 36 kA at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Feeder and motor branch circuit protection in manufacturing, process, and building services environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact NSX100F footprint suits space-constrained control panels and motor control centres (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial \u0026amp; Infrastructure:\u003c\/strong\u003e Suitable for HVAC, pump, and compressor feeder circuits in commercial and industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589737755,"sku":"C10F3TM080","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm080-case-circuit-breaker_bdb4805c-d710-4a0a-8db3-28f537c78bb8.jpg?v=1777164363"},{"product_id":"schneider-c10f3tm100-nsx100f-100a-3p-36ka-mccb","title":"Schneider Electric C10F3TM100 NSX100F 3-Pole 100A 36kA Compact NSX Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F3TM100 NSX100F is a 3-pole 100A moulded case circuit breaker from the Compact NSX series, delivering a breaking capacity of 36 kA at 415V AC. Engineered for industrial power distribution and control panel protection, this MCCB provides reliable overcurrent and short-circuit protection in demanding automation environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F3TM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Protects feeders and sub-circuits in main distribution boards and motor control centres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Protection:\u003c\/strong\u003e Suitable for factory automation panels requiring reliable short-circuit and overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Infrastructure:\u003c\/strong\u003e Ideal for commercial and industrial buildings requiring 100A branch circuit protection at 415V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Circuit Protection:\u003c\/strong\u003e Used as a main disconnecting means and protective device for large motor loads in industrial automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229589901595,"sku":"C10F3TM100","price":165.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f3tm100-case-circuit-breaker_80f903fd-4809-4535-b1da-3ddb8df53dd4.jpg?v=1777164367"},{"product_id":"schneider-c10f6tm016-nsx100f-4p-16a-36ka-mccb","title":"Schneider Electric C10F6TM016 NSX100F 4P 16A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F6TM016 is a Compact NSX100F series moulded case circuit breaker (MCCB) rated at 16A with a 4-pole configuration and an ultimate breaking capacity of 36 kA at 415V AC. Designed for industrial power distribution and panel protection applications, the NSX100F C10F6TM016 delivers reliable overcurrent and short-circuit protection in demanding environments where robust performance and compact footprint are essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F6TM016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Power Distribution:\u003c\/strong\u003e Suitable for protecting outgoing circuits in main and sub-distribution boards in factories, manufacturing plants, and process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Protection:\u003c\/strong\u003e Ideal for use as a main or branch circuit breaker inside motor control centers (MCCs) and industrial control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Applicable in commercial electrical installations requiring robust 4-pole protection up to 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator \u0026amp; Transformer Protection:\u003c\/strong\u003e The 36 kA breaking capacity makes C10F6TM016 suitable for protection close to transformers and generators with high fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrastructure Projects:\u003c\/strong\u003e Commonly specified in data centers, utility rooms, and critical power infrastructure where reliable overcurrent protection is mandatory.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229593047323,"sku":"C10F6TM016","price":203.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f6tm016-case-circuit-breaker_f6aceb8a-3fa6-4cb5-b577-674e5437f2b3.jpg?v=1777164371"},{"product_id":"schneider-electric-c10f6tm025-nsx100f-mccb","title":"Schneider Electric C10F6TM025 ComPacT NSX100F 4P 25 A 36 kA TM-D Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F6TM025 is a 4P, 25 A ComPacT NSX100F moulded case circuit breaker fitted with a TM-D thermal-magnetic trip unit rated for 36 kA breaking capacity at 380\/415 V AC. It carries a 690 V rated operational voltage and mounts on a fixed backplate, suited to distribution circuits sized to its 25 A nameplate rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC10F6TM025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P (neutral pole not current-protected, 3D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e25 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 8 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 36 kA at 380\/415 V AC, 4 kA at 660\/690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit\u003c\/td\u003e\n\u003ctd\u003eTM-D (thermal-magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection function\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment range\u003c\/td\u003e\n\u003ctd\u003e[Ir] adjustable 0.7...1x In; [Ii] fixed 300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for isolation\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eFixed, backplate mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside\/downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e140 x 161 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe F frame sits at the entry tier of the ComPacT NSX100 breaking-capacity ladder (36 kA at 380\/415 V AC), below the N (50 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. The TM-D trip unit on this C10F6TM025 variant allows thermal pickup to be trimmed 0.7...1x In of the 25 A nameplate rating, giving some margin to match the protected cable or feeder without stepping to a different current size in the F frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229593112859,"sku":"C10F6TM025","price":189.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f6tm025-nsx100f-mccb.jpg?v=1790868187"},{"product_id":"schneider-c10f6tm032-nsx100f-4p-32a-36ka-mccb","title":"Schneider Electric C10F6TM032 NSX100F 4P 32A 36kA Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C10F6TM032 is a Compact NSX100F series 4-pole moulded case circuit breaker rated at 32A with a breaking capacity of 36 kA at 415V AC, engineered for reliable overcurrent and short-circuit protection in industrial and commercial power distribution panels. Designed for demanding environments, this circuit breaker delivers robust performance in 3-phase and neutral switching applications where dependable fault interruption is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC10F6TM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact NSX100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Panel Boards:\u003c\/strong\u003e Suitable as a main or branch circuit breaker in motor control centres and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Buildings:\u003c\/strong\u003e Provides overcurrent protection for HVAC systems, lighting distribution, and building services at 415V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Ideal for protecting machinery and equipment against short-circuit and overload faults in 4-wire (3-phase + neutral) installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Used in sub-distribution panels where a compact, high breaking capacity MCCB is required in constrained enclosure spaces.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229593375003,"sku":"C10F6TM032","price":203.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c10f6tm032-case-circuit-breaker_73628250-ce0f-4e2b-8b28-09ac0c4b2cc0.jpg?v=1777164375"}],"url":"https:\/\/stoklink.com\/collections\/schneider-compact-nsx.oembed","provider":"Stoklink","version":"1.0","type":"link"}