{"title":"Schneider ComPacT NS MCCBs","description":"\u003cp\u003eSchneider Electric ComPacT NS MCCBs are high-current molded case circuit breakers for 630 A to 1600 A feeders and incomers. The range covers 3-pole and 4-pole breakers with MicroLogic electronic trip units, with more than 160 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNS630b to NS1600 frames, including NS800 and NS1000.\u003c\/li\u003e\n\u003cli\u003eN, H and L breaking capacity classes, up to 150 kA on NS800L.\u003c\/li\u003e\n\u003cli\u003eMicroLogic 2.0 and 5.0 electronic trip units.\u003c\/li\u003e\n\u003cli\u003eFor lower ratings see \u003ca href=\"\/collections\/schneider-compact-nsx\"\u003eSchneider ComPacT NSX MCCBs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFrame and rating must cover the feeder current.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity class must exceed the prospective short-circuit current.\u003c\/li\u003e\n\u003cli\u003eMicroLogic version sets the protection functions: 2.0 for long-time and instantaneous, 5.0 adds short-time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhen does a feeder need an NS instead of an NSX?\u003c\/h3\u003e\u003cp\u003eAbove 630 A. NSX frames stop at 630 A, so NS covers the range up to 1600 A.\u003c\/p\u003e\u003ch3\u003eWhat is MicroLogic 5.0?\u003c\/h3\u003e\u003cp\u003eIt is an electronic trip unit with adjustable long-time, short-time and instantaneous protection (LSI).\u003c\/p\u003e\u003ch3\u003eDo you ship ComPacT NS breakers abroad?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-c063h320fm","title":"Schneider Electric C063H320FM ComPacT NS630bH 3P 630 A 70 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063H320FM is a 3-pole ComPacT NS630bH moulded case circuit breaker rated 630 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063H320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS630bH line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229521514779,"sku":"C063H320FM","price":1274.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063h320fm-ns630bh-mccb.jpg?v=1790867889"},{"product_id":"schneider-electric-c063h35efm","title":"Schneider Electric C063H35EFM ComPacT NS630bH 3P 630 A 70 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063H35EFM is a 3-pole ComPacT NS630bH moulded case circuit breaker rated 630 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063H35EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS630bH line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229521645851,"sku":"C063H35EFM","price":1588.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063h35efm-ns630bh-mccb.jpg?v=1790867897"},{"product_id":"schneider-electric-c063h420fm","title":"Schneider Electric C063H420FM ComPacT NS630bH 4P 630 A 70 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063H420FM is a 4-pole ComPacT NS630bH moulded case circuit breaker rated 630 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063H420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS630bH line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229521711387,"sku":"C063H420FM","price":1766.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063h420fm-ns630bh-mccb.jpg?v=1790867906"},{"product_id":"schneider-electric-c063h450fm","title":"Schneider Electric C063H450FM ComPacT NS630bH 4P 630 A 70 kA MicroLogic 5.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063H450FM is a 4-pole ComPacT NS630bH moulded case circuit breaker rated 630 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063H450FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS630bH line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229521776923,"sku":"C063H450FM","price":1911.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063h450fm-ns630bh-mccb.jpg?v=1790867915"},{"product_id":"schneider-electric-c063n320fm","title":"Schneider Electric C063N320FM ComPacT NS630bN 3P 630 A 50 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063N320FM is a 3-pole ComPacT NS630bN moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063N320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 630 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229522039067,"sku":"C063N320FM","price":1207.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063n320fm-ns630bn-mccb.jpg?v=1790867924"},{"product_id":"schneider-electric-c063n350fm","title":"Schneider Electric C063N350FM ComPacT NS630bN 3P 630 A 50 kA MicroLogic 5.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063N350FM is a 3-pole ComPacT NS630bN moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063N350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 630 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229522497819,"sku":"C063N350FM","price":1353.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063n350fm-ns630bn-mccb.jpg?v=1790867933"},{"product_id":"schneider-electric-c063n35afm","title":"Schneider Electric C063N35AFM ComPacT NS630bN 3P 630 A 50 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063N35AFM is a 3-pole ComPacT NS630bN moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 A trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063N35AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 630 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229522563355,"sku":"C063N35AFM","price":1448.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063n35afm-ns630bn-mccb.jpg?v=1790867942"},{"product_id":"schneider-electric-c063n420fm","title":"Schneider Electric C063N420FM ComPacT NS630bN 4P 630 A 50 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063N420FM is a 4-pole ComPacT NS630bN moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063N420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 630 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229522759963,"sku":"C063N420FM","price":1663.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063n420fm-ns630bn-mccb.jpg?v=1790867951"},{"product_id":"schneider-electric-c063n450fm","title":"Schneider Electric C063N450FM ComPacT NS630bN 4P 630 A 50 kA MicroLogic 5.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C063N450FM is a 4-pole ComPacT NS630bN moulded case circuit breaker rated 630 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC063N450FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630bN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 630 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229523611931,"sku":"C063N450FM","price":1808.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c063n450fm-ns630bn-mccb.jpg?v=1790867959"},{"product_id":"schneider-electric-c080h320fm","title":"Schneider Electric C080H320FM ComPacT NS800H 3P 800 A 70 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H320FM is a 3-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229524267291,"sku":"C080H320FM","price":1422.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h320fm-ns800h-mccb.jpg?v=1790867967"},{"product_id":"schneider-electric-c080h32afm","title":"Schneider Electric C080H32AFM ComPacT NS800H 3P 800 A 70 kA MicroLogic 2.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H32AFM is a 3-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 A trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H32AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 A, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229524889883,"sku":"C080H32AFM","price":1489.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h32afm-ns800h-mccb.jpg?v=1790867975"},{"product_id":"schneider-electric-c080h35efm","title":"Schneider Electric C080H35EFM ComPacT NS800H 3P 800 A 70 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H35EFM is a 3-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H35EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229525545243,"sku":"C080H35EFM","price":1736.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h35efm-ns800h-mccb.jpg?v=1790867984"},{"product_id":"schneider-electric-c080h420fm","title":"Schneider Electric C080H420FM ComPacT NS800H 4P 800 A 70 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H420FM is a 4-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229526167835,"sku":"C080H420FM","price":1890.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h420fm-ns800h-mccb.jpg?v=1790867993"},{"product_id":"schneider-electric-c080h42efm","title":"Schneider Electric C080H42EFM ComPacT NS800H 4P 800 A 70 kA MicroLogic 2.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H42EFM is a 4-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H42EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 E, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229526888731,"sku":"C080H42EFM","price":2009.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h42efm-ns800h-mccb.jpg?v=1790868002"},{"product_id":"schneider-electric-c080h450fm","title":"Schneider Electric C080H450FM ComPacT NS800H 4P 800 A 70 kA MicroLogic 5.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H450FM is a 4-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H450FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229527707931,"sku":"C080H450FM","price":2036.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h450fm-ns800h-mccb.jpg?v=1790868011"},{"product_id":"schneider-electric-c080h45afm","title":"Schneider Electric C080H45AFM ComPacT NS800H 4P 800 A 70 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H45AFM is a 4-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 A trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H45AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229528494363,"sku":"C080H45AFM","price":2131.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h45afm-ns800h-mccb.jpg?v=1790868021"},{"product_id":"schneider-electric-c080h45efm","title":"Schneider Electric C080H45EFM ComPacT NS800H 4P 800 A 70 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080H45EFM is a 4-pole ComPacT NS800H moulded case circuit breaker rated 800 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080H45EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS800H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229529182491,"sku":"C080H45EFM","price":2205.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080h45efm-ns800h-mccb.jpg?v=1790868029"},{"product_id":"schneider-electric-c080l320fm","title":"Schneider Electric C080L320FM ComPacT NS800L 3P 800 A 150 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080L320FM is a 3-pole ComPacT NS800L moulded case circuit breaker rated 800 A, with a 150 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080L320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA Icu at 220\/240 V AC 50\/60 Hz, 150 kA Icu at 380\/415 V AC 50\/60 Hz, 130 kA Icu at 440 V AC 50\/60 Hz, 100 kA Icu at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA at 220\/240 V AC 50\/60 Hz, 150 kA at 380\/415 V AC 50\/60 Hz, 130 kA at 440 V AC 50\/60 Hz, 100 kA at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The L-frame rating gives it 150 kA Icu at 380\/415 V AC, the highest breaking-capacity class in the 800 A frame; reserve it for incomers close to the transformer or otherwise exposed to prospective fault currents above what the H-frame sibling can clear.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229529870619,"sku":"C080L320FM","price":2394.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080l320fm-ns800l-mccb.jpg?v=1790868038"},{"product_id":"schneider-c080n320fm-compact-ns800n-800a-3p-mccb","title":"Schneider Electric C080N320FM ComPacT NS800N 3P 800A 50kA Fixed Molded-Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N320FM is a ComPacT NS800N molded-case circuit breaker delivering 800A rated current with a 50 kA breaking capacity at 415V AC, designed for robust overcurrent and short-circuit protection in industrial power distribution panels. This 3-pole, fixed-mount MCCB is built to IEC\/CEI standards, making it a reliable choice for demanding commercial and industrial electrical installations requiring high-performance protection up to 415V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded-Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed and tested in accordance with IEC\/CEI international electrotechnical standards for molded-case circuit breakers, ensuring compliance with global industrial safety and performance requirements.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229530525979,"sku":"C080N320FM","price":1346.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n320fm-molded-case-circuit-breaker_378c8aa6-066c-4120-8332-fd4da3af952d.jpg?v=1777164305"},{"product_id":"schneider-electric-c080n32afm","title":"Schneider Electric C080N32AFM ComPacT NS800N 3P 800 A 50 kA MicroLogic 2.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N32AFM is a 3-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 A trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N32AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 A, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229531279643,"sku":"C080N32AFM","price":1344.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n32afm-ns800n-mccb.jpg?v=1790868047"},{"product_id":"schneider-electric-c080n32efm","title":"Schneider Electric C080N32EFM ComPacT NS800N 3P 800 A 50 kA MicroLogic 2.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N32EFM is a 3-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N32EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 E, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229532360987,"sku":"C080N32EFM","price":1395.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n32efm-ns800n-mccb.jpg?v=1790868056"},{"product_id":"schneider-c080n350fm-compact-ns800n-800a-3p-50ka-mccb","title":"Schneider Electric C080N350FM ComPacT NS800N 3P 800A 50kA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N350FM is a ComPacT NS800N series 3-pole moulded case circuit breaker rated at 800A with a breaking capacity of 50 kA at 415V AC, designed for reliable overcurrent and short-circuit protection in industrial power distribution and control panel applications. This fixed-mount MCCB delivers robust performance in demanding environments where high fault levels require dependable interruption capability. Weighing 14 kg, it is built to IEC\/CEI standards and is suited for main incomer and feeder protection duties across commercial and heavy industrial installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 New Generation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed and tested in accordance with IEC\/CEI international electrotechnical standards for moulded case circuit breakers, ensuring verified performance for switching, protection, and breaking capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain incomer protection for industrial switchboards and distribution panels\u003c\/li\u003e\n  \u003cli\u003eFeeder circuit protection in manufacturing plants and process facilities\u003c\/li\u003e\n  \u003cli\u003ePower distribution in commercial buildings, data centres, and utilities\u003c\/li\u003e\n  \u003cli\u003eMotor feeder and group motor protection in automation and control systems\u003c\/li\u003e\n  \u003cli\u003eGenerator and transformer output protection requiring high breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229533212955,"sku":"C080N350FM","price":1499.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n350fm-case-circuit-breaker_0ba1fc1c-8aba-41c7-b257-62f3e2f5b0e1.jpg?v=1777164309"},{"product_id":"schneider-electric-c080n35efm","title":"Schneider Electric C080N35EFM ComPacT NS800N 3P 800 A 50 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N35EFM is a 3-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N35EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229534785819,"sku":"C080N35EFM","price":1591.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n35efm-ns800n-mccb.jpg?v=1790867889"},{"product_id":"schneider-electric-c080n420fm","title":"Schneider Electric C080N420FM ComPacT NS800N 4P 800 A 50 kA MicroLogic 2.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N420FM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229536227611,"sku":"C080N420FM","price":1776.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n420fm-ns800n-mccb.jpg?v=1790867897"},{"product_id":"schneider-electric-c080n42efm","title":"Schneider Electric C080N42EFM ComPacT NS800N 4P 800 A 50 kA MicroLogic 2.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N42EFM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N42EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 E, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229537800475,"sku":"C080N42EFM","price":1895.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n42efm-ns800n-mccb.jpg?v=1790867905"},{"product_id":"schneider-electric-c080n450fm","title":"Schneider Electric C080N450FM ComPacT NS800N 4P 800 A 50 kA MicroLogic 5.0 Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N450FM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N450FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229539438875,"sku":"C080N450FM","price":1921.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n450fm-ns800n-mccb.jpg?v=1790867914"},{"product_id":"schneider-electric-c080n45afm","title":"Schneider Electric C080N45AFM ComPacT NS800N 4P 800 A 50 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N45AFM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 A trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N45AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229541142811,"sku":"C080N45AFM","price":2016.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n45afm-ns800n-mccb.jpg?v=1790867923"},{"product_id":"schneider-electric-c080n45efm","title":"Schneider Electric C080N45EFM ComPacT NS800N 4P 800 A 50 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C080N45EFM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC080N45EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS800N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229542256923,"sku":"C080N45EFM","price":2091.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c080n45efm-ns800n-mccb.jpg?v=1790867932"},{"product_id":"schneider-electric-c100h320fm","title":"Schneider Electric C100H320FM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 2.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H320FM is a 3-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229542551835,"sku":"C100H320FM","price":1729.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h320fm-ns1000h-mccb.jpg?v=1790867942"},{"product_id":"schneider-electric-c100h32efm","title":"Schneider Electric C100H32EFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 2.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H32EFM is a 3-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H32EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 E, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229543010587,"sku":"C100H32EFM","price":1848.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h32efm-ns1000h-mccb.jpg?v=1790867950"},{"product_id":"schneider-electric-c100h350fm","title":"Schneider Electric C100H350FM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H350FM is a 3-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229543338267,"sku":"C100H350FM","price":1874.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h350fm-ns1000h-mccb.jpg?v=1790867959"},{"product_id":"schneider-electric-c100h35efm","title":"Schneider Electric C100H35EFM ComPacT NS1000H 3P 1000 A 70 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H35EFM is a 3-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H35EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229543633179,"sku":"C100H35EFM","price":2044.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h35efm-ns1000h-mccb.jpg?v=1790867968"},{"product_id":"schneider-electric-c100h420fm","title":"Schneider Electric C100H420FM ComPacT NS1000H 4P 1000 A 70 kA MicroLogic 2.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H420FM is a 4-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229543928091,"sku":"C100H420FM","price":2201.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h420fm-ns1000h-mccb.jpg?v=1790867977"},{"product_id":"schneider-electric-c100h45efm","title":"Schneider Electric C100H45EFM ComPacT NS1000H 4P 1000 A 70 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100H45EFM is a 4-pole ComPacT NS1000H moulded case circuit breaker rated 1000 A, with a 70 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 E trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100H45EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 70 kA Icu at 380\/415 V AC 50\/60 Hz, 65 kA Icu at 440 V AC 50\/60 Hz, 50 kA Icu at 500\/525 V AC 50\/60 Hz, 42 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC 50\/60 Hz, 52 kA at 380\/415 V AC 50\/60 Hz, 48 kA at 440 V AC 50\/60 Hz, 37 kA at 500\/525 V AC 50\/60 Hz, 31 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The H-frame rating gives it 70 kA Icu at 380\/415 V AC; within the NS1000H line this is the class to pick when the calculated prospective short-circuit current at the installation point is at or below that figure without derating to the L-frame. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229544190235,"sku":"C100H45EFM","price":2515.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100h45efm-ns1000h-mccb.jpg?v=1790867985"},{"product_id":"schneider-electric-c100l320fm","title":"Schneider Electric C100L320FM ComPacT NS1000L 3P 1000 A 150 kA MicroLogic 2.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100L320FM is a 3-pole ComPacT NS1000L moulded case circuit breaker rated 1000 A, with a 150 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100L320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA Icu at 220\/240 V AC 50\/60 Hz, 150 kA Icu at 380\/415 V AC 50\/60 Hz, 130 kA Icu at 440 V AC 50\/60 Hz, 100 kA Icu at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA at 220\/240 V AC 50\/60 Hz, 150 kA at 380\/415 V AC 50\/60 Hz, 130 kA at 440 V AC 50\/60 Hz, 100 kA at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The L-frame rating gives it 150 kA Icu at 380\/415 V AC, the highest breaking-capacity class in the 1000 A frame; reserve it for incomers close to the transformer or otherwise exposed to prospective fault currents above what the H-frame sibling can clear.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229544517915,"sku":"C100L320FM","price":2618.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100l320fm-ns1000l-mccb.jpg?v=1790867995"},{"product_id":"schneider-electric-c100l350fm","title":"Schneider Electric C100L350FM ComPacT NS1000L 3P 1000 A 150 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100L350FM is a 3-pole ComPacT NS1000L moulded case circuit breaker rated 1000 A, with a 150 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100L350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA Icu at 220\/240 V AC 50\/60 Hz, 150 kA Icu at 380\/415 V AC 50\/60 Hz, 130 kA Icu at 440 V AC 50\/60 Hz, 100 kA Icu at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA at 220\/240 V AC 50\/60 Hz, 150 kA at 380\/415 V AC 50\/60 Hz, 130 kA at 440 V AC 50\/60 Hz, 100 kA at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The L-frame rating gives it 150 kA Icu at 380\/415 V AC, the highest breaking-capacity class in the 1000 A frame; reserve it for incomers close to the transformer or otherwise exposed to prospective fault currents above what the H-frame sibling can clear.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229546123547,"sku":"C100L350FM","price":2763.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100l350fm-ns1000l-mccb.jpg?v=1790868005"},{"product_id":"schneider-electric-c100l35afm","title":"Schneider Electric C100L35AFM ComPacT NS1000L 3P 1000 A 150 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100L35AFM is a 3-pole ComPacT NS1000L moulded case circuit breaker rated 1000 A, with a 150 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 A trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100L35AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA Icu at 220\/240 V AC 50\/60 Hz, 150 kA Icu at 380\/415 V AC 50\/60 Hz, 130 kA Icu at 440 V AC 50\/60 Hz, 100 kA Icu at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA at 220\/240 V AC 50\/60 Hz, 150 kA at 380\/415 V AC 50\/60 Hz, 130 kA at 440 V AC 50\/60 Hz, 100 kA at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The L-frame rating gives it 150 kA Icu at 380\/415 V AC, the highest breaking-capacity class in the 1000 A frame; reserve it for incomers close to the transformer or otherwise exposed to prospective fault currents above what the H-frame sibling can clear.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229546451227,"sku":"C100L35AFM","price":2872.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100l35afm-ns1000l-mccb.jpg?v=1790868015"},{"product_id":"schneider-electric-c100l420fm","title":"Schneider Electric C100L420FM ComPacT NS1000L 4P 1000 A 150 kA MicroLogic 2.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100L420FM is a 4-pole ComPacT NS1000L moulded case circuit breaker rated 1000 A, with a 150 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100L420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA Icu at 220\/240 V AC 50\/60 Hz, 150 kA Icu at 380\/415 V AC 50\/60 Hz, 130 kA Icu at 440 V AC 50\/60 Hz, 100 kA Icu at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kA at 220\/240 V AC 50\/60 Hz, 150 kA at 380\/415 V AC 50\/60 Hz, 130 kA at 440 V AC 50\/60 Hz, 100 kA at 500\/525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral protection setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The L-frame rating gives it 150 kA Icu at 380\/415 V AC, the highest breaking-capacity class in the 1000 A frame; reserve it for incomers close to the transformer or otherwise exposed to prospective fault currents above what the H-frame sibling can clear. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229546778907,"sku":"C100L420FM","price":3245.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100l420fm-ns1000l-mccb.jpg?v=1790868023"},{"product_id":"schneider-c100n320fm-ns1000n-1000a-3p-50ka-mccb","title":"Schneider Electric C100N320FM ComPacT NS1000N 3P 1000A 50kA Fixed Molded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N320FM is a ComPacT NS1000N series 3-pole molded case circuit breaker (MCCB) rated at 1000A with a breaking capacity of 50 kA at 415V AC, designed for fixed mounting in industrial power distribution and control panel applications. Built to IEC\/CEI standards, this robust MCCB provides reliable overload and short-circuit protection for demanding industrial environments. Weighing 14 kg, the C100N320FM offers the performance and dependability expected from Schneider Electric's ComPacT NS New Generation platform.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 New Generation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed, tested, and certified in compliance with IEC\/CEI international electrotechnical standards for molded case circuit breakers, ensuring safety and interoperability in global industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and feeder circuit protection in industrial switchboards and distribution panels\u003c\/li\u003e\n  \u003cli\u003eMotor circuit and transformer protection in manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003ePower distribution in commercial buildings, utilities, and infrastructure projects\u003c\/li\u003e\n  \u003cli\u003eFixed installation in MCC (Motor Control Center) enclosures\u003c\/li\u003e\n  \u003cli\u003eProtection against overloads and short-circuits in heavy-duty industrial automation systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229547073819,"sku":"C100N320FM","price":1737.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n320fm-case-circuit-breaker_00d68958-b560-4b72-a7df-2b8e48c4cce8.jpg?v=1777164314"},{"product_id":"schneider-electric-c100n32afm","title":"Schneider Electric C100N32AFM ComPacT NS1000N 3P 1000 A 50 kA MicroLogic 2.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N32AFM is a 3-pole ComPacT NS1000N moulded case circuit breaker rated 1000 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 A trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N32AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 A, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 1000 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229547401499,"sku":"C100N32AFM","price":1713.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n32afm-ns1000n-mccb.jpg?v=1790868032"},{"product_id":"schneider-electric-c100n32efm","title":"Schneider Electric C100N32EFM ComPacT NS1000N 3P 1000 A 50 kA MicroLogic 2.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N32EFM is a 3-pole ComPacT NS1000N moulded case circuit breaker rated 1000 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N32EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 E, Electronic, LI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Ii 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Energy meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 1000 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229547729179,"sku":"C100N32EFM","price":1764.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n32efm-ns1000n-mccb.jpg?v=1790868041"},{"product_id":"schneider-electric-c100n350fm","title":"Schneider Electric C100N350FM ComPacT NS1000N 3P 1000 A 50 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N350FM is a 3-pole ComPacT NS1000N moulded case circuit breaker rated 1000 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 1000 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229547991323,"sku":"C100N350FM","price":1790.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n350fm-ns1000n-mccb.jpg?v=1790868050"},{"product_id":"schneider-electric-c100n35afm","title":"Schneider Electric C100N35AFM ComPacT NS1000N 3P 1000 A 50 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N35AFM is a 3-pole ComPacT NS1000N moulded case circuit breaker rated 1000 A, with a 50 kA breaking capacity (Icu) at 380\/415 V AC. It is fitted with a MicroLogic 5.0 A trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection (LSI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N35AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current [In]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage [Ue]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage [Ui]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage [Uimp]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity [Icu]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 kA Icu at 220\/240 V AC 50\/60 Hz, 50 kA Icu at 380\/415 V AC 50\/60 Hz, 50 kA Icu at 440 V AC 50\/60 Hz, 40 kA Icu at 500\/525 V AC 50\/60 Hz, 30 kA Icu at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService breaking capacity [Ics]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC 50\/60 Hz, 50 kA at 380\/415 V AC 50\/60 Hz, 50 kA at 440 V AC 50\/60 Hz, 40 kA at 500\/525 V AC 50\/60 Hz, 30 kA at 660\/690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-time withstand current [Icw]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kA 1 s conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A, Electronic, LSI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection adjustment ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIr 0.4...1 x In; tr 12.5…600 s at 1.5 x Ir | 0.5…24 s at 6 x Ir | 0.7…16.6 s at 7.2 x Ir; Isd 1.5...10 x Ir, tsd 0.1…0.4 s I²t=on | 0…0.4 s I²t=off; Ii Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD display (Ammeter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone selective interlocking (ZSI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type \/ Mounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside\/downside, pitch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front, pitch 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions W x H x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm (W) x 327 mm (H) x 147 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP \/ IK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40, IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIts LSI trip unit adds an adjustable short-time delay (Isd, tsd) on top of the long-time overload and instantaneous stages, which lets it hold a short-time withstand for selective coordination with downstream breakers instead of tripping instantaneously on every fault. The built-in ammeter display gives a local RMS current reading without needing a separate panel meter. The N-frame rating gives it 50 kA Icu at 380\/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 1000 A when the prospective fault current at the installation point exceeds this breaker's Icu.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229548319003,"sku":"C100N35AFM","price":1885.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n35afm-ns1000n-mccb.jpg?v=1790868059"},{"product_id":"schneider-c100n420fm-ns1000n-1000a-4p-50ka-mccb","title":"Schneider Electric C100N420FM ComPacT NS1000N 4P 1000A 50kA Fixed Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N420FM is a ComPacT NS1000N 4-pole 1000A moulded case circuit breaker (MCCB) delivering a 50 kA breaking capacity at 415V AC in a fixed mounting configuration. Engineered for demanding industrial power distribution and motor protection applications, this heavy-duty MCCB combines robust overcurrent protection with a compact footprint suitable for switchboards and control panels requiring high fault-current interruption performance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC100N420FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComPacT NS1000N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoulded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIEC\/CEI:\u003c\/strong\u003e Designed and tested in accordance with IEC\/CEI international electrotechnical standards for moulded case circuit breakers, ensuring compliance with global industrial installation requirements.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229548777755,"sku":"C100N420FM","price":2203.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n420fm-case-circuit-breaker_57f02ddf-bc3e-4f91-9b4f-e5f87b2357ea.jpg?v=1777164319"},{"product_id":"schneider-electric-c100n42afm-compact-ns1000n-mccb","title":"Schneider Electric C100N42AFM ComPacT NS1000N 4P 1000 A 50 kA MicroLogic 2.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N42AFM is a 4-pole, 1000 A ComPacT NS1000N moulded case circuit breaker rated for 50 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 2.0 A electronic trip unit delivering long-time overload and instantaneous short-circuit protection, and is rated up to 690 V AC for standard-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC100N42AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1000 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Ii (instantaneous): 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display\u003c\/td\u003e\n\u003ctd\u003eLCD display – Ammeter (RMS current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e280 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N-frame classification gives the C100N42AFM 50 kA Icu at 380\/415 V AC, sized for standard distribution duty on the 1000 A frame; where fault levels run higher, the H-frame version of the same frame size delivers a higher Icu without a change in footprint. Its MicroLogic 2.0 A trip unit covers long-time overload and instantaneous protection only (LI), with no short-time delay stage — choose a 5.0 (LSI) or 6.0 (LSIG) trip unit from this same frame where selective coordination with downstream breakers is required. The A suffix adds a digital LCD screen with an RMS ammeter, giving it a local current readout without a separate meter. With 4 poles and a neutral protection setting adjustable between 0.5× Ir (3D + N\/2) and 1× Ir (4D), it suits TN-S or TT systems that need their own neutral overload protection; the 3-pole version of the same frame is for 3-phase-only loads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229549072667,"sku":"C100N42AFM","price":2156.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n42afm-compact-ns1000n-mccb.jpg?v=1790868081"},{"product_id":"schneider-electric-c100n450fm-compact-ns1000n-mccb","title":"Schneider Electric C100N450FM ComPacT NS1000N 4P 1000 A 50 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N450FM is a 4-pole, 1000 A ComPacT NS1000N moulded case circuit breaker rated for 50 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 5.0 electronic trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection, and is rated up to 690 V AC for standard-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC100N450FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1000 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Isd (short-time, 9 settings): 1.5...10 x Ir; Ii (instantaneous): Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e280 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N-frame classification gives the C100N450FM 50 kA Icu at 380\/415 V AC, sized for standard distribution duty on the 1000 A frame; where fault levels run higher, the H-frame version of the same frame size delivers a higher Icu without a change in footprint. Its MicroLogic 5.0 trip unit adds a short-time delay stage over the 2.0 (LI) units in this frame, letting it hold through a downstream breaker's instantaneous trip for selective coordination on a main or sub-main application. The base MicroLogic 5.0 unit has no digital display — settings are read off the dial markings, with no RMS or energy readout. With 4 poles and a neutral protection setting adjustable between 0.5× Ir (3D + N\/2) and 1× Ir (4D), it suits TN-S or TT systems that need their own neutral overload protection; the 3-pole version of the same frame is for 3-phase-only loads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229549531419,"sku":"C100N450FM","price":2233.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n450fm-compact-ns1000n-mccb.jpg?v=1790868090"},{"product_id":"schneider-electric-c100n45afm-compact-ns1000n-mccb","title":"Schneider Electric C100N45AFM ComPacT NS1000N 4P 1000 A 50 kA MicroLogic 5.0 A Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N45AFM is a 4-pole, 1000 A ComPacT NS1000N moulded case circuit breaker rated for 50 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 5.0 A electronic trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection, and is rated up to 690 V AC for standard-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC100N45AFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1000 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Isd (short-time, 9 settings): 1.5...10 x Ir; Ii (instantaneous): Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display\u003c\/td\u003e\n\u003ctd\u003eLCD display – Ammeter (RMS current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e280 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N-frame classification gives the C100N45AFM 50 kA Icu at 380\/415 V AC, sized for standard distribution duty on the 1000 A frame; where fault levels run higher, the H-frame version of the same frame size delivers a higher Icu without a change in footprint. Its MicroLogic 5.0 A trip unit adds a short-time delay stage over the 2.0 (LI) units in this frame, letting it hold through a downstream breaker's instantaneous trip for selective coordination on a main or sub-main application. The A suffix adds a digital LCD screen with an RMS ammeter, giving it a local current readout without a separate meter. With 4 poles and a neutral protection setting adjustable between 0.5× Ir (3D + N\/2) and 1× Ir (4D), it suits TN-S or TT systems that need their own neutral overload protection; the 3-pole version of the same frame is for 3-phase-only loads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229550285083,"sku":"C100N45AFM","price":2328.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n45afm-compact-ns1000n-mccb.jpg?v=1790868101"},{"product_id":"schneider-electric-c100n45efm-compact-ns1000n-mccb","title":"Schneider Electric C100N45EFM ComPacT NS1000N 4P 1000 A 50 kA MicroLogic 5.0 E Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C100N45EFM is a 4-pole, 1000 A ComPacT NS1000N moulded case circuit breaker rated for 50 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 5.0 E electronic trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection, and is rated up to 690 V AC for standard-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC100N45EFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1000 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e50 kA at 220\/240 V AC, 50 kA at 380\/415 V AC, 50 kA at 440 V AC, 40 kA at 500\/525 V AC, 30 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0 E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Isd (short-time, 9 settings): 1.5...10 x Ir; Ii (instantaneous): Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display\u003c\/td\u003e\n\u003ctd\u003eLCD display – Ammeter and energy meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeutral protection setting\u003c\/td\u003e\n\u003ctd\u003eNo protection (3D) | 0.5 x Ir (3D + N\/2) | 1 x Ir (4D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e280 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe N-frame classification gives the C100N45EFM 50 kA Icu at 380\/415 V AC, sized for standard distribution duty on the 1000 A frame; where fault levels run higher, the H-frame version of the same frame size delivers a higher Icu without a change in footprint. Its MicroLogic 5.0 E trip unit adds a short-time delay stage over the 2.0 (LI) units in this frame, letting it hold through a downstream breaker's instantaneous trip for selective coordination on a main or sub-main application. The E suffix adds a digital LCD screen with an energy meter on top of the ammeter standard on the A version, so it can also serve as a sub-metering point. With 4 poles and a neutral protection setting adjustable between 0.5× Ir (3D + N\/2) and 1× Ir (4D), it suits TN-S or TT systems that need their own neutral overload protection; the 3-pole version of the same frame is for 3-phase-only loads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229550711067,"sku":"C100N45EFM","price":2402.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c100n45efm-compact-ns1000n-mccb.jpg?v=1790868110"},{"product_id":"schneider-electric-c125h320fm-compact-ns1250h-mccb","title":"Schneider Electric C125H320FM ComPacT NS1250H 3P 1250 A 70 kA MicroLogic 2.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C125H320FM is a 3-pole, 1250 A ComPacT NS1250H moulded case circuit breaker rated for 70 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 2.0 electronic trip unit delivering long-time overload and instantaneous short-circuit protection, and is rated up to 690 V AC for high-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC125H320FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1250 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 65 kA at 440 V AC, 50 kA at 500\/525 V AC, 42 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC, 52 kA at 380\/415 V AC, 48 kA at 440 V AC, 37 kA at 500\/525 V AC, 31 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Ii (instantaneous): 1.5...10 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e210 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe H-frame classification gives the C125H320FM 70 kA Icu at 380\/415 V AC — choose it over the N-frame version of the same 1250 A frame when prospective short-circuit current at the installation point runs above standard distribution levels. Its MicroLogic 2.0 trip unit covers long-time overload and instantaneous protection only (LI), with no short-time delay stage — choose a 5.0 (LSI) or 6.0 (LSIG) trip unit from this same frame where selective coordination with downstream breakers is required. The base MicroLogic 2.0 unit has no digital display — settings are read off the dial markings, with no RMS or energy readout. At 210 mm wide on 3 poles, it suits 3-phase-only distribution with no neutral protection; the 4-pole version of the same frame is available where the neutral conductor must be switched and protected.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229551137051,"sku":"C125H320FM","price":1926.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c125h320fm-compact-ns1250h-mccb.jpg?v=1790868119"},{"product_id":"schneider-electric-c125h350fm-compact-ns1250h-mccb","title":"Schneider Electric C125H350FM ComPacT NS1250H 3P 1250 A 70 kA MicroLogic 5.0 Moulded Case Circuit Breaker","description":"\u003cp\u003eThe Schneider Electric C125H350FM is a 3-pole, 1250 A ComPacT NS1250H moulded case circuit breaker rated for 70 kA breaking capacity (Icu) at 380\/415 V AC. Fixed-mounted and manually operated, it carries a MicroLogic 5.0 electronic trip unit delivering long-time overload, short-time delay and instantaneous short-circuit protection, and is rated up to 690 V AC for high-breaking-capacity distribution duty in the ComPacT NS630b...1600 new generation line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eC125H350FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eComPacT NS630b...1600 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of poles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[In] Rated current\u003c\/td\u003e\n\u003ctd\u003e1250 A at 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] Rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] Rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] Rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e85 kA at 220\/240 V AC, 70 kA at 380\/415 V AC, 65 kA at 440 V AC, 50 kA at 500\/525 V AC, 42 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService breaking capacity (Ics)\u003c\/td\u003e\n\u003ctd\u003e52 kA at 220\/240 V AC, 52 kA at 380\/415 V AC, 48 kA at 440 V AC, 37 kA at 500\/525 V AC, 31 kA at 660\/690 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] Short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e19.2 kA, 1 s (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category \/ suitability for isolation\u003c\/td\u003e\n\u003ctd\u003eCategory B; suitable for isolation (Yes, EN\/IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit name\u003c\/td\u003e\n\u003ctd\u003eMicroLogic 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit technology\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip unit protection functions\u003c\/td\u003e\n\u003ctd\u003eLSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection pick-up \u0026amp; time-delay adjustment ranges\u003c\/td\u003e\n\u003ctd\u003eIr (long-time, 9 settings): 0.4...1 x In; Isd (short-time, 9 settings): 1.5...10 x Ir; Ii (instantaneous): Off | 2...15 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl \/ mounting\u003c\/td\u003e\n\u003ctd\u003eManually operated, Fixed (Backplate support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection (upside \/ downside)\u003c\/td\u003e\n\u003ctd\u003eFront \/ Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e210 × 327 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP \/ IK degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature (operation)\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIECEE CB Scheme\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe H-frame classification gives the C125H350FM 70 kA Icu at 380\/415 V AC — choose it over the N-frame version of the same 1250 A frame when prospective short-circuit current at the installation point runs above standard distribution levels. Its MicroLogic 5.0 trip unit adds a short-time delay stage over the 2.0 (LI) units in this frame, letting it hold through a downstream breaker's instantaneous trip for selective coordination on a main or sub-main application. The base MicroLogic 5.0 unit has no digital display — settings are read off the dial markings, with no RMS or energy readout. At 210 mm wide on 3 poles, it suits 3-phase-only distribution with no neutral protection; the 4-pole version of the same frame is available where the neutral conductor must be switched and protected.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229551857947,"sku":"C125H350FM","price":2071.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-c125h350fm-compact-ns1250h-mccb.jpg?v=1790868128"}],"url":"https:\/\/stoklink.com\/collections\/schneider-compact-ns.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}