{"title":"Schneider ATS490 Soft Starters","description":null,"products":[{"product_id":"schneider-electric-ats490c11y-altivar-soft-starter-110a","title":"Schneider Electric ATS490C11Y Altivar ATS490 110A 208-690V AC 55 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C11Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 110 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 55 kW at 400 V (45 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C11Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 234 x 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 110 A normal duty, the ATS490C11Y covers motors up to 55 kW at 400 V; size on the heavy-duty rating (88 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 55 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281290011,"sku":"ATS490C11Y","price":1619.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c11y-altivar-soft-starter-ats490.jpg?v=1790303161"},{"product_id":"schneider-electric-ats490c14y-altivar-soft-starter-140a","title":"Schneider Electric ATS490C14Y Altivar ATS490 140A 208-690V AC 75 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C14Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 140 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 75 kW at 400 V (55 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C14Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 235 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 140 A normal duty, the ATS490C14Y covers motors up to 75 kW at 400 V; size on the heavy-duty rating (110 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 75 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281322779,"sku":"ATS490C14Y","price":1845.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c14y-altivar-soft-starter-ats490.jpg?v=1790303174"},{"product_id":"schneider-electric-ats490c17y-altivar-soft-starter-170a","title":"Schneider Electric ATS490C17Y Altivar ATS490 170A 208-690V AC 90 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C17Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 170 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 90 kW at 400 V (75 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C17Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 235 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 170 A normal duty, the ATS490C17Y covers motors up to 90 kW at 400 V; size on the heavy-duty rating (140 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 90 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281421083,"sku":"ATS490C17Y","price":2264.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c17y-altivar-soft-starter-ats490.jpg?v=1790303186"},{"product_id":"schneider-electric-ats490c21y-altivar-soft-starter-210a","title":"Schneider Electric ATS490C21Y Altivar ATS490 210A 208-690V AC 110 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C21Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 210 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 110 kW at 400 V (90 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C21Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948866\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 265 x 443 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 210 A normal duty, the ATS490C21Y covers motors up to 110 kW at 400 V; size on the heavy-duty rating (170 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 110 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281486619,"sku":"ATS490C21Y","price":2544.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c21y-altivar-soft-starter-ats490.jpg?v=1790303197"},{"product_id":"schneider-electric-ats490c25y-altivar-soft-starter-250a","title":"Schneider Electric ATS490C25Y Altivar ATS490 250A 208-690V AC 132 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C25Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 250 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 132 kW at 400 V (110 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C25Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 265 x 443 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 250 A normal duty, the ATS490C25Y covers motors up to 132 kW at 400 V; size on the heavy-duty rating (210 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 132 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038281617691,"sku":"ATS490C25Y","price":2731.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c25y-altivar-soft-starter-ats490.jpg?v=1790303209"},{"product_id":"schneider-electric-ats490c32y-altivar-soft-starter-320a","title":"Schneider Electric ATS490C32Y Altivar ATS490 320A 208-690V AC 160 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C32Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 320 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 160 kW at 400 V (132 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C32Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206 x 265 x 443 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 320 A normal duty, the ATS490C32Y covers motors up to 160 kW at 400 V; size on the heavy-duty rating (250 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 160 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038283518235,"sku":"ATS490C32Y","price":3428.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c32y-altivar-soft-starter-ats490.jpg?v=1790303224"},{"product_id":"schneider-electric-ats490c41y-altivar-soft-starter-410a","title":"Schneider Electric ATS490C41Y Altivar ATS490 410A 208-690V AC 220 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C41Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 410 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 220 kW at 400 V (160 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C41Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 x 300 x 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 410 A normal duty, the ATS490C41Y covers motors up to 220 kW at 400 V; size on the heavy-duty rating (320 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 220 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038283616539,"sku":"ATS490C41Y","price":4148.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c41y-altivar-soft-starter-ats490.jpg?v=1790303236"},{"product_id":"schneider-electric-ats490c48y-altivar-soft-starter-480a","title":"Schneider Electric ATS490C48Y Altivar ATS490 480A 208-690V AC 250 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C48Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 480 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 250 kW at 400 V (220 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C48Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 x 300 x 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 480 A normal duty, the ATS490C48Y covers motors up to 250 kW at 400 V; size on the heavy-duty rating (410 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 250 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038283649307,"sku":"ATS490C48Y","price":4896.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c48y-altivar-soft-starter-ats490.jpg?v=1790303247"},{"product_id":"schneider-electric-ats490c59y-altivar-soft-starter-590a","title":"Schneider Electric ATS490C59Y Altivar ATS490 590A 208-690V AC 315 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C59Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 590 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 315 kW at 400 V (250 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C59Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e590 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 x 300 x 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 590 A normal duty, the ATS490C59Y covers motors up to 315 kW at 400 V; size on the heavy-duty rating (480 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 315 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038283747611,"sku":"ATS490C59Y","price":5688.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c59y-altivar-soft-starter-ats490.jpg?v=1790303259"},{"product_id":"schneider-electric-ats490c66y-altivar-soft-starter-660a","title":"Schneider Electric ATS490C66Y Altivar ATS490 660A 208-690V AC 355 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C66Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 660 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 355 kW at 400 V (315 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C66Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948927\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e590 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 x 300 x 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 660 A normal duty, the ATS490C66Y covers motors up to 355 kW at 400 V; size on the heavy-duty rating (590 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 355 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038286172443,"sku":"ATS490C66Y","price":6479.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c66y-altivar-soft-starter-ats490.jpg?v=1790303271"},{"product_id":"schneider-electric-ats490c79y-altivar-soft-starter-790a","title":"Schneider Electric ATS490C79Y Altivar ATS490 790A 208-690V AC 400 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490C79Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 790 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 400 kW at 400 V (355 kW in heavy duty), with Safe Torque Off (SIL 1 \/ PL c) built into the drive logic. A native Modbus TCP\/EtherNet\/IP port and 300 VA control supply support supervised motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490C79Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e790 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e436 x 350 x 580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 790 A normal duty, the ATS490C79Y covers motors up to 400 kW at 400 V; size on the heavy-duty rating (660 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 400 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038286631195,"sku":"ATS490C79Y","price":8466.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490c79y-altivar-soft-starter-ats490.jpg?v=1790303287"},{"product_id":"schneider-electric-ats490d17y-altivar-soft-starter-17a","title":"Schneider Electric ATS490D17Y Altivar ATS490 17A 208-690V AC 7.5 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D17Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 17 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 7.5 kW at 400 V (5.5 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D17Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 185 x 283 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 17 A normal duty, the ATS490D17Y sits at the entry end of the ATS490 frame and covers motors up to 7.5 kW at 400 V without stepping up to a larger enclosure. Choose the heavy-duty rating (12 A) instead of the normal-duty figure when the load cycles frequently or starts against high inertia, since it keeps the same 400% Ie \/ 13 s overload margin with a lower continuous current. Applications with variable or quadratic torque, such as pumps, fans, compressors and conveyors, fit the normal-duty rating; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. For motors above 7.5 kW at 400 V, move up to the next current frame in the ATS490 range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038286696731,"sku":"ATS490D17Y","price":916.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d17y-altivar-soft-starter-ats490.jpg?v=1790303303"},{"product_id":"schneider-electric-ats490d22y-altivar-soft-starter-22a","title":"Schneider Electric ATS490D22Y Altivar ATS490 22A 208-690V AC 11 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D22Y is a three-phase Altivar Soft Starter from the ATS490 range, rated 22 A continuous (normal duty) on a 208-690 V AC supply. It starts and stops asynchronous motors up to 11 kW at 400 V (7.5 kW in heavy duty), using torque control instead of a fixed voltage ramp. Safe Torque Off and a native Modbus TCP\/EtherNet\/IP port support supervised, cybersecure motor control from the same enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D22Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948767\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...690 V AC (-15...+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110...230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 digital inputs, 3 relay outputs, 2 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 234 x 283 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 22 A normal duty, the ATS490D22Y covers motors up to 11 kW at 400 V; size on the heavy-duty rating (17 A) instead when the load cycles frequently or starts against high inertia, since the 400% Ie \/ 13 s overload window is the same but the continuous current is lower. Variable or quadratic-torque loads such as pumps, fans, compressors and conveyors fit the normal-duty figure; cyclic loads like crushers and grinders should be sized on the heavy-duty current instead. Motors above 11 kW at 400 V call for the next current frame up in the ATS490 range; motors below it can drop to the next frame down to avoid oversizing the starter.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038286795035,"sku":"ATS490D22Y","price":943.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d22y-altivar-soft-starter-ats490.jpg?v=1790303315"},{"product_id":"schneider-electric-ats490d32y-soft-starter","title":"Schneider Electric ATS490D32Y Altivar ATS490 32 A 208-690V 3-Phase 15 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D32Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 32 A continuous (22 A in heavy duty) and drives up to 15 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D32Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948774\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 32 A normal-duty rating covers motors up to 15 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 22 A for motors up to 11 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038286893339,"sku":"ATS490D32Y","price":972.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d32y-ats490-soft-starter.jpg?v=1790303327"},{"product_id":"schneider-electric-ats490d38y-soft-starter","title":"Schneider Electric ATS490D38Y Altivar ATS490 38 A 208-690V 3-Phase 18.5 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D38Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 38 A continuous (32 A in heavy duty) and drives up to 18.5 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D38Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 38 A normal-duty rating covers motors up to 18.5 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 32 A for motors up to 15 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287024411,"sku":"ATS490D38Y","price":1006.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d38y-ats490-soft-starter.jpg?v=1790303339"},{"product_id":"schneider-electric-ats490d47y-soft-starter","title":"Schneider Electric ATS490D47Y Altivar ATS490 47 A 208-690V 3-Phase 22 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D47Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 47 A continuous (38 A in heavy duty) and drives up to 22 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D47Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948798\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 47 A normal-duty rating covers motors up to 22 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 38 A for motors up to 18.5 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287057179,"sku":"ATS490D47Y","price":1052.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d47y-ats490-soft-starter.jpg?v=1790303351"},{"product_id":"schneider-electric-ats490d62y-soft-starter","title":"Schneider Electric ATS490D62Y Altivar ATS490 62 A 208-690V 3-Phase 30 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D62Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 62 A continuous (47 A in heavy duty) and drives up to 30 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D62Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 62 A normal-duty rating covers motors up to 30 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 47 A for motors up to 22 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287122715,"sku":"ATS490D62Y","price":1118.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d62y-ats490-soft-starter.jpg?v=1790303363"},{"product_id":"schneider-electric-ats490d75y-soft-starter","title":"Schneider Electric ATS490D75Y Altivar ATS490 75 A 208-690V 3-Phase 37 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D75Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 75 A continuous (62 A in heavy duty) and drives up to 37 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D75Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 75 A normal-duty rating covers motors up to 37 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 62 A for motors up to 30 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287221019,"sku":"ATS490D75Y","price":1178.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d75y-ats490-soft-starter.jpg?v=1790303374"},{"product_id":"schneider-electric-ats490d88y-soft-starter","title":"Schneider Electric ATS490D88Y Altivar ATS490 88 A 208-690V 3-Phase 45 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490D88Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 88 A continuous (75 A in heavy duty) and drives up to 45 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP20 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490D88Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948828\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289 x 160 x 234 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 88 A normal-duty rating covers motors up to 45 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 75 A for motors up to 37 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287253787,"sku":"ATS490D88Y","price":1376.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490d88y-ats490-soft-starter.jpg?v=1790303385"},{"product_id":"schneider-electric-ats490m10y-soft-starter","title":"Schneider Electric ATS490M10Y Altivar ATS490 1000 A 208-690V 3-Phase 500 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490M10Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 1000 A continuous (790 A in heavy duty) and drives up to 500 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP00 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490M10Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e790 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 x 436 x 350 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1000 A normal-duty rating covers motors up to 500 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 790 A for motors up to 400 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch. As an IP00 frame, the ATS490M10Y ships without a plastic enclosure and is intended for installation inside a dedicated switchgear cabinet rather than direct panel mounting.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287352091,"sku":"ATS490M10Y","price":9283.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490m10y-ats490-soft-starter.jpg?v=1790303397"},{"product_id":"schneider-electric-ats490m12y-soft-starter","title":"Schneider Electric ATS490M12Y Altivar ATS490 1200 A 208-690V 3-Phase 630 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS490M12Y is a soft starter from the Altivar Soft Starter ATS490 range, built to ramp asynchronous motors smoothly from a 208-690 V AC supply. In normal duty it carries 1200 A continuous (1045 A in heavy duty) and drives up to 630 kW at 400 V. It integrates Safe Torque Off, native Modbus TCP\/EtherNet\/IP, and IP00 protection for enclosure mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS490M12Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606486948958\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Normal Duty (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1045 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc, logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V, Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, Modbus TCP\/EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 1 (IEC 61508), PL c \/ Category 2 (ISO 13849)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Current Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400% Ie for 13 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 2 A \/ 250 V AC (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 degC (without derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 x 436 x 350 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1200 A normal-duty rating covers motors up to 630 kW at 400 V; where the load runs a more demanding duty cycle, the heavy-duty curve drops to 1045 A for motors up to 500 kW. The 400% Ie for 13 s overload profile sets how long the starter tolerates a stalled or jammed load before tripping, relevant when sizing against pump or conveyor startup torque. The integrated Safe Torque Off input meets SIL 1 \/ PL c without an external safety contactor on the motor branch. As an IP00 frame, the ATS490M12Y ships without a plastic enclosure and is intended for installation inside a dedicated switchgear cabinet rather than direct panel mounting.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS490 range targets pumps, fans, compressors, conveyors, mixers, cutters, grinders, and crushers where a controlled, torque-limited start reduces mechanical and electrical stress at startup.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54038287384859,"sku":"ATS490M12Y","price":9877.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats490m12y-ats490-soft-starter.jpg?v=1790303409"}],"url":"https:\/\/stoklink.com\/collections\/schneider-ats490.oembed","provider":"Stoklink","version":"1.0","type":"link"}