{"title":"Schneider Altistart Soft Starters","description":"\u003cp\u003eSchneider Electric Altistart soft starters cover 3 A to 1,200 A and 1.1 kW to 630 kW for 3-phase induction motors. The family includes the older ATS01 and ATS22 and the newer Altivar ATS430, ATS480 and ATS490. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eATS01 and Altistart U01: compact units for small motors on 380 to 415 V or 200 to 480 V.\u003c\/li\u003e\n\u003cli\u003eATS22: mid-range units from about 4 kW up to 90 kW and beyond, with spare parts such as VW3G22 kits.\u003c\/li\u003e\n\u003cli\u003eAltivar ATS430, ATS480 and ATS490: advanced starters up to 690 V, with ATS490 reaching high-power ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor rated current and supply voltage: 230 to 440 V, 380 to 415 V or up to 690 V.\u003c\/li\u003e\n\u003cli\u003eSeries: basic ATS01, general ATS22, or ATS480 and ATS490 for heavy duty and communication.\u003c\/li\u003e\n\u003cli\u003eStarting duty and torque control requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between ATS22 and ATS480?\u003c\/h3\u003e\u003cp\u003eATS22 is the earlier general-purpose range. ATS480 is a newer Altivar starter with more setup options and built-in communication.\u003c\/p\u003e\u003ch3\u003eCan I replace an ATS01 with an ATS22?\u003c\/h3\u003e\u003cp\u003eThe fit depends on current rating, voltage and wiring. Compare nameplate data first, then confirm the mounting and control terminals.\u003c\/p\u003e\u003ch3\u003eDo you ship Altistart units outside Turkey?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-ats01n103ft-ats01","title":"ATS01N103FT, ATS01 Series Soft Starter, 1,1 kW, 3 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection\u003e\n\u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e\n\u003cp\u003eSchneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003chr\u003e\n\u003csection\u003e\n\u003ch3\u003eProduct Description: Schneider Electric ATS01N103FT\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric ATS01N103FT is a compact DIN-rail soft starter rated for 3 A and intended for straightforward industrial motor starting tasks. It supports a wide supply voltage range (nominally 110–480 V AC and with verified limits of approximately 99–528 V) and is suitable for small asynchronous motors: verified motor power ratings include approximately 0.37 kW for single-phase 230 V motors, 0.55 kW (three-phase) at around 230 V and up to 1.1 kW (three-phase) at around 400 V. The unit uses a voltage-ramp (phase-angle) control method to limit inrush current and reduce mechanical stress during acceleration. ATS01N103FT includes an integrated bypass contact and is intended for simple machines such as pumps, fans, compressors, conveyors and automatic doors where basic soft starting (no advanced torque or multi-step control) is required. Key practical advantages are its very small 22.5 mm width for tight control panels, simple two‑setting configuration for quick commissioning, and IP20 enclosure for panel mounting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 3 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e ~0.37 kW (1‑phase 230 V); 0.55 kW (3‑phase 230 V); 1.1 kW (3‑phase 400 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e Nominal 110–480 V AC (verified operating limits ~99–528 V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (soft start \/ phase-angle control)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Basic overload\/starting current management (no integrated advanced torque control)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e — (no communication interface confirmed for this model)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (panel enclosure mounting)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eWhat motor sizes can ATS01N103FT start?\u003c\/h4\u003e\n\u003cp\u003eVerified ratings: approximately 0.37 kW for single‑phase 230 V motors, 0.55 kW for three‑phase at ~230 V, and 1.1 kW for three‑phase at ~400 V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4\u003eWhat supply voltages does the ATS01N103FT support?\u003c\/h4\u003e\n\u003cp\u003eThe unit is specified for a wide nominal voltage range 110–480 V AC, with documented operating limits near 99–528 V AC and operation at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4\u003eDoes this model include an internal bypass?\u003c\/h4\u003e\n\u003cp\u003eYes — ATS01N103FT is supplied with an integrated bypass contact to reduce dissipation and noise after start-up.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4\u003eCan I use ATS01N103FT for heavy-duty torque control or multi-step starts?\u003c\/h4\u003e\n\u003cp\u003eNo. This ATS01 model provides a basic voltage‑ramp soft start intended for simple machines; it does not include advanced torque control or multi-step starting functions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230282551579,"sku":"ATS01N103FT","price":103.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n103ft-ats01-to-400v-ac_b271e219-73ba-4982-a2f5-2ec5f13c5c81.jpg?v=1777185246"},{"product_id":"schneider-electric-ats01n106ft-ats01","title":"ATS01N106FT, ATS01 Series Soft Starter, 2,2 kW, 6 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N106FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N106FT is an Altistart 01 soft starter rated for 6 A nominal current and designed for wide-voltage installations. It supports a supply voltage range from 110 V up to 480 V AC, making it suitable for both low-voltage single-phase and three-phase systems commonly found in industrial control panels. Typical motor compatibility includes small asynchronous motors — documented examples are 0.75 kW at 230 V and up to 2.2 kW at 400 V — which makes the unit appropriate for light-duty pumps, fans, conveyors and compressors on simple machines. The ATS01N106FT uses a voltage-ramp start method to limit inrush current and reduce mechanical stress during acceleration, includes an internal bypass contactor to reduce heat losses after starting, and is supplied in an IP20 enclosure for panel mounting. This model does not include integrated motor overload protection or advanced communications; it is targeted at applications requiring a compact, easy-to-configure motor soft starter for basic industrial motor starting and to extend mechanical and electrical equipment life. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 6 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Example: 0.75 kW at 230 V; up to 2.2 kW at 400 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110…480 V AC (wide range)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (soft start)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass contactor)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (panel mounting)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eUtilisation Category:\u003c\/strong\u003e AC-53B (EN\/IEC 60947-4-2)\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat voltage range does the ATS01N106FT support?\u003c\/h4\u003e \u003cp\u003eThe ATS01N106FT supports a wide supply voltage range from 110 V to 480 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can this soft starter handle?\u003c\/h4\u003e \u003cp\u003eDocumented examples include 0.75 kW at 230 V and up to 2.2 kW at 400 V; it is intended for small motors on simple machines.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N106FT include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — an internal bypass contactor is provided to reduce dissipation after the motor has started.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes this model provide built-in motor overload protection or communications?\u003c\/h4\u003e \u003cp\u003eNo. The ATS01N106FT does not include integrated motor overload protection or communication interfaces; external protection and monitoring are required if needed.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230282617115,"sku":"ATS01N106FT","price":113.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n106ft-ats01-to-400v-ac_22ebca63-f5d6-4238-bad2-d59d58ac1d80.jpg?v=1777185251"},{"product_id":"schneider-electric-ats01n109ft-ats01","title":"ATS01N109FT, ATS01 Series Soft Starter, 4 kW, 9 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N109FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N109FT is a compact Altistart 01 soft starter rated for 9 A nominal operational current, designed for simple industrial motor starting tasks. It accepts a wide supply voltage range from 110 V to 480 V AC and is suitable for inline three-phase motor powers up to approximately 1.5 kW at 230 V and 4 kW at 400 V (motor power ratings depend on wiring and voltage). The unit is DIN-rail or panel mountable (45 mm width), includes an internal bypass contactor to reduce heat dissipation during run, and provides adjustable starting time and torque suppression (starting torque typically adjustable in the 30–80% range). Built for basic motor control use, the ATS01N109FT is a practical choice for small conveyors, pumps, fans, compressors and other simple motor-driven machines where space is limited and a straightforward motor soft starter is required. Confirmed environmental and mechanical specs include IP20 protection, -10 °C to 40 °C operation without derating (with derating above 40 °C), and compliance with EN\/IEC 60947-4-2. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 9 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e up to ~1.5 kW at 230 V (inline); up to ~4 kW at 400 V (inline)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110–480 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e adjustable voltage ramp \/ torque suppression (starting torque adjustable ~30–80%)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass contactor)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e basic functions provided via soft start control (no integrated overload protection confirmed)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e — (no communication interface confirmed)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS01N109FT?\u003c\/h4\u003e \u003cp\u003eThe ATS01N109FT is rated for 9 A nominal operational current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS01N109FT support?\u003c\/h4\u003e \u003cp\u003eIt supports a wide supply voltage range from 110 V to 480 V AC (50–60 Hz).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N109FT include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes. The unit includes an integrated internal bypass contactor to reduce heat dissipation during motor run.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes and applications is this model suitable for?\u003c\/h4\u003e \u003cp\u003eIt is suitable for small motor-driven machines: roughly up to 1.5 kW at 230 V and up to 4 kW at 400 V (inline). Typical uses include pumps, fans, conveyors, compressors and other simple industrial loads.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat are the operating temperature limits and derating requirements?\u003c\/h4\u003e \u003cp\u003eRated for operation from -10 °C to 40 °C without derating; above 40 °C the current must be derated as specified by Schneider Electric (consult product documentation for exact derating curve).\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230282846491,"sku":"ATS01N109FT","price":118.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n109ft-ats01-to-400v-ac_28060c14-cfbf-4fd7-88a3-ab6d40395f0f.jpg?v=1777185255"},{"product_id":"schneider-electric-ats01n112ft-ats01","title":"ATS01N112FT, ATS01 Series Soft Starter, 5,5 kW, 12 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N112FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N112FT is a compact ATS01-series motor soft starter with a rated operational current of 12 A and a wide supply voltage range (nominally 110…480 V). It is sized for small to medium asynchronous motors — typical in-line motor ratings quoted for this model include approximately 1.5 kW for single-phase 230 V motors, 2.2 kW for three-phase 230 V motors and up to 5.5 kW for three-phase 400 V motors (manufacturer power-range groupings also list 1.1–2 kW at 200–240 V 1‑phase, 2.2–3 kW at 200–240 V 3‑phase and 4–6 kW at 380–440 V 3‑phase). The device uses a voltage-ramp soft start (start with voltage ramp) with adjustable starting time (1 to 5 s) to limit inrush current and reduce mechanical stress during acceleration. The ATS01N112FT includes an internal bypass to reduce heat dissipation once the motor reaches speed and is designed for simple machine applications — pumps, fans and compressors — where basic soft starting and low-configuration operation are required. It is a compact, IP20-protected unit with no integrated motor overload relay, and it accepts common control supply voltages (control supply options include 110–240 V AC and 24 V DC as specified by Schneider Electric). \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 12 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 1.1–2 kW (200–240 V 1‑phase); 2.2–3 kW (200–240 V 3‑phase); 4–6 kW (380–440 V 3‑phase). Manufacturer examples: 1.5 kW (1‑phase 230 V), 2.2 kW (3‑phase 230 V), 5.5 kW (3‑phase 400 V).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110…480 V (nominal supply range)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (start with voltage ramp), adjustable start time 1–5 s\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (internal bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection (requires external protection)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage:\u003c\/strong\u003e 110–240 V AC and 24 V DC (control supply options)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes does the ATS01N112FT support?\u003c\/h4\u003e \u003cp\u003eThe ATS01N112FT is specified for small to medium motors: manufacturer power-groupings cover roughly 1.1–2 kW (200–240 V single‑phase), 2.2–3 kW (200–240 V three‑phase) and 4–6 kW (380–440 V three‑phase); example ratings cited include 1.5 kW (230 V 1‑ph), 2.2 kW (230 V 3‑ph) and 5.5 kW (400 V 3‑ph).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the supply voltage range for this soft starter?\u003c\/h4\u003e \u003cp\u003eThe unit accepts a wide supply voltage range: nominal 110…480 V (suitable for 110–480 V networks as specified by Schneider Electric).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N112FT include motor overload protection?\u003c\/h4\u003e \u003cp\u003eNo. The ATS01N112FT does not include integrated motor overload protection; an external overload or motor protector must be used where required.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust starting behavior (time\/torque)?\u003c\/h4\u003e \u003cp\u003eYes. The starter uses a voltage-ramp start with adjustable starting time (adjustable from 1 to 5 seconds) to tailor acceleration and limit inrush current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs there a bypass after starting to reduce heat?\u003c\/h4\u003e \u003cp\u003eYes. The ATS01N112FT includes an internal bypass to reduce dissipation and noise after the motor reaches running speed.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283043099,"sku":"ATS01N112FT","price":120.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n112ft-ats01-to-400v-ac_fde4c3a1-9152-46bc-90c2-306a144ac188.jpg?v=1777185259"},{"product_id":"schneider-electric-ats01n125ft-ats01","title":"ATS01N125FT, ATS01 Series Soft Starter, 11 kW, 25 A, 230 to 400V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N125FT\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N125FT is a compact Altistart 01 soft starter rated for 25 A nominal current and a wide supply voltage range of 110–480 V AC (50\/60 Hz). It is designed for basic soft start\/stop of asynchronous motors and is typically applied to three-phase motor sizes up to about 11 kW (depending on voltage). The unit uses a voltage-ramp start method to limit inrush current and reduce mechanical stress during acceleration, making it suitable for conveyors, pumps, fans, compressors and other simple motor-driven machines that do not require advanced torque control. The ATS01N125FT is DIN-rail mountable, includes an integrated bypass to reduce dissipation during run, and has an IP20 enclosure rating — features that support tight panel layouts and straightforward installation for maintenance and procurement teams. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 25 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 2.2 – 11 kW (application dependent on supply voltage)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 110 – 480 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (soft start \/ soft stop)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can the ATS01N125FT handle?\u003c\/h4\u003e \u003cp\u003eThe ATS01N125FT is specified for motor power up to approximately 11 kW (three‑phase) with a nominal current rating of 25 A; lower kW ratings apply at lower supply voltages.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS01N125FT support?\u003c\/h4\u003e \u003cp\u003eIt accepts a wide supply range from 110 V to 480 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N125FT include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — the model includes an integrated bypass to minimise dissipation once the motor is at nominal speed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich control method does this soft starter use?\u003c\/h4\u003e \u003cp\u003eThe ATS01N125FT uses a voltage-ramp start\/stop method to limit starting current and reduce mechanical stress.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283108635,"sku":"ATS01N125FT","price":160.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n125ft-ats01-to-400v-ac_b8905616-c6a6-48fe-87b9-b62133e247de.jpg?v=1777185262"},{"product_id":"schneider-electric-ats01n206qn-ats01","title":"ATS01N206QN, ATS01 Series Soft Starter, 2,2 kW, 6 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N206QN\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N206QN is a compact ATS01 series soft starter rated for 6 A continuous current and intended for three-phase supply voltages in the 380–415 V AC range. It is specified to control small asynchronous motors in the approximate power range of 1.5 kW to 2.2 kW (typical 2.2 kW at 400\/415 V). The unit provides voltage ramp soft-start and soft-stop functionality with adjustable start and stop times (commonly 1…10 s), letting you limit inrush current and reduce mechanical stress on pumps, fans and light-duty compressors. The ATS01N206QN is a no-frills, DIN-mountable soft starter with IP20 protection, simple front potentiometer adjustments (start time, stop time, start voltage threshold), status LEDs and basic I\/O for run\/stop and BOOST functions plus an end-of-start\/stop relay output—features that make it suitable for straightforward industrial motor starting tasks where compact size and ease of setup are priorities. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 6 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e ~1.5 kW – 2.2 kW (at 380–415 V AC)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 3 × 380…415 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp (soft start \/ soft stop)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection \/ Control Functions:\u003c\/strong\u003e Adjustable start\/stop ramp, start voltage threshold, BOOST function, end-of-start relay output\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl I\/O:\u003c\/strong\u003e Logic inputs for Run\/Stop and BOOST; logic output and one relay output (end-of-start \/ motor at standstill)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltage does the Schneider ATS01N206QN require?\u003c\/h4\u003e \u003cp\u003eThe ATS01N206QN is designed for three-phase supplies in the 380–415 V AC range.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes is the ATS01N206QN suitable for?\u003c\/h4\u003e \u003cp\u003eIt is intended for small asynchronous motors around 1.5 kW up to 2.2 kW (typical rating at 400\/415 V).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of this soft starter?\u003c\/h4\u003e \u003cp\u003eThe rated operational current is 6 A (at 40 °C ambient as specified by the product documentation).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust start and stop behaviour on the ATS01N206QN?\u003c\/h4\u003e \u003cp\u003eYes. The unit provides adjustable start and stop ramp settings (commonly 1…10 seconds) and an adjustable start-voltage threshold plus a BOOST input for torque boost during start.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283206939,"sku":"ATS01N206QN","price":125.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n206qn-ats01-to-415v-ac_33fc35ec-aa81-447e-a750-48bf26a8dc47.jpg?v=1777185266"},{"product_id":"schneider-electric-ats01n209qn-ats01","title":"ATS01N209QN, ATS01 Series Soft Starter, 4 kW, 9 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N209QN\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N209QN is a compact Altistart 01 soft starter rated for 9 A nominal current and intended for three-phase supply voltages in the 380–415 V class. It is specified for motors up to 4 kW (at 400 V) and delivers a voltage-ramp start\/stop method with adjustable ramp and deceleration times (1 to 10 s). The unit provides reduced starting current and torque control in the range of approximately 30–80% of direct-on-line torque, making it suitable for light-duty industrial machines such as pumps, fans, small compressors, conveyors, automatic doors and other simple motor-driven systems. Key verified characteristics include an integrated bypass to reduce dissipation once the motor is at full speed, DIN-rail\/panel friendly compact form factor (45 mm width), and IP20 enclosure rating — attributes that simplify installation in confined control panels and OEM assemblies. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 9 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 4 kW at 380–415 V (three-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 380…415 V AC (supply limits 342…456 V)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start\/stop (adjustable 1–10 s)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection (basic starter functions only)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStarting Torque:\u003c\/strong\u003e Adjustable approx. 30% to 80% of direct-on-line motor torque\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS01N209QN?\u003c\/h4\u003e \u003cp\u003eThe ATS01N209QN is rated for 9 A nominal operational current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltage and motor size does this model support?\u003c\/h4\u003e \u003cp\u003eIt is designed for 3-phase supplies 380–415 V AC and is specified for motors up to 4 kW at 400 V.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N209QN include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — the unit features an integrated bypass to reduce heat dissipation and noise once the motor reaches nominal speed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eHow is start\/stop timing configured on this starter?\u003c\/h4\u003e \u003cp\u003eStart and stop use a voltage ramp with adjustable ramp and deceleration times from 1 to 10 seconds.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283338011,"sku":"ATS01N209QN","price":132.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n209qn-ats01-to-415v-ac_b2d4eafb-0489-4ad1-98a8-530dfa6cf905.jpg?v=1777185271"},{"product_id":"schneider-electric-ats01n212qn-ats01","title":"ATS01N212QN, ATS01 Series Soft Starter, 5,5 kW, 12 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N212QN\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N212QN is a DIN-rail Altistart 01 soft starter rated for 12 A nominal current and designed for 3-phase supply voltages in the 380–415 V class (supply limits commonly listed as 342–456 V). It is specified for motors up to 5.5 kW (three-phase, at 380–415 V), making it suitable for small to medium machines such as pumps, fans, compressors, conveyors and other simple driven equipment where controlled, low-complexity starts are required. The ATS01N212QN uses a voltage-ramp start method, includes an integrated bypass to reduce dissipation during run, and offers simple LED indication and basic I\/O for start\/stop and end-of-start signalling. Physical packaging is compact (approx. 124 × 45 × 131 mm) and the unit is IP20 rated for enclosure-mounted installations. Ambient operation is specified to 40 °C without derating, with a higher range up to 50 °C subject to current derating. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 12 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 5.5 kW (3-phase, 380–415 V)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 380…415 V (operating range reported 342…456 V)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStarting Time Adjustment:\u003c\/strong\u003e Adjustable (typical range 1 to 10 s)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can the ATS01N212QN start?\u003c\/h4\u003e \u003cp\u003eThe ATS01N212QN is specified for motors up to 5.5 kW on a 3-phase 380–415 V supply (nominal 12 A rating).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS01N212QN support?\u003c\/h4\u003e \u003cp\u003eRated for 380–415 V three-phase operation; supplier datasheets list a wider supply limits window (about 342–456 V).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes this model include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — the ATS01N212QN includes an integrated bypass to minimise heat dissipation after the motor reaches nominal speed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust the start and stop times on the ATS01N212QN?\u003c\/h4\u003e \u003cp\u003eYes — starting and deceleration times are adjustable (commonly quoted range is 1 to 10 seconds for start\/stop ramps).\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283436315,"sku":"ATS01N212QN","price":149.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n212qn-ats01-to-415v-ac_bc53fa65-a06e-4fb0-971d-6ad18c80f7e9.jpg?v=1777185275"},{"product_id":"schneider-electric-ats01n222lu-ats01","title":"ATS01N222LU, ATS01 Series Soft Starter, 11 kW, 22 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N222LU\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N222LU is a compact DIN-rail Altistart 01 soft starter rated for 22 A continuous operation and intended for 3-phase supply voltages of 200–240 V AC. It is suitable for motor ratings typically from about 4 kW up to 5.5 kW (approx. 5–7.5 hp) at 200–240 V, making it a practical choice for small to medium machines such as pumps, fans, compressors, conveyor drives and automated doors where simple soft starting is required. The unit uses a voltage-ramp start method with an adjustable start\/stop ramp (commonly 1 to 10 s) and provides an integrated electronic bypass to reduce heat dissipation and audible noise after starting. Physically slim (≈45 mm wide) and DIN-rail mountable, the ATS01N222LU is designed for straightforward installation and basic on-site configuration with a small number of settings and discrete control inputs for start\/stop and boost functions. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 22 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e ~4 kW to 5.5 kW at 200–240 V (approximately 5–7.5 hp)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 200–240 V AC, 3-phase (50\/60 Hz)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start \/ adjustable ramp time (typ. 1–10 s)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection: No (starter provides start control and signalling outputs)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDiscrete Control \/ I\/O:\u003c\/strong\u003e Logic discrete inputs (LI1, LI2, BOOST) and relay \/ open-collector signalling outputs\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (DIN-rail, panel-mountable)\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum continuous current for the ATS01N222LU?\u003c\/h4\u003e \u003cp\u003eThe ATS01N222LU is rated for 22 A continuous (Ie) operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich motor sizes and voltage class does this soft starter support?\u003c\/h4\u003e \u003cp\u003eIt is intended for 3-phase motors on 200–240 V AC supplies, typically around 4 kW up to 5.5 kW (≈5–7.5 hp) depending on application and duty.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N222LU include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eYes — the model includes an integrated electronic bypass to reduce heat and noise after the motor reaches line voltage.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eHow is start\/stop timing configured on this model?\u003c\/h4\u003e \u003cp\u003eStart and stop ramp times are adjustable (commonly configurable in the 1 to 10 second range) using the unit’s simple configuration controls.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283534619,"sku":"ATS01N222LU","price":208.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n222lu-ats01-to-415v-ac_b63883d8-692d-4d85-b02a-ac89099213dd.jpg?v=1777185279"},{"product_id":"schneider-electric-ats01n222qn-ats01","title":"ATS01N222QN, ATS01 Series Soft Starter, 11 kW, 22 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N222QN\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N222QN is a compact reduced-voltage soft starter with a rated operational current of 22 A designed for three-phase 380–415 V AC motor supplies. Its nominal motor power compatibility is in the 7.5–11 kW range (depending on voltage and motor rating), making this unit appropriate for standard industrial loads such as pumps, fans and compressors where straightforward soft starting is required. The ATS01N222QN provides basic soft-start functionality to limit inrush current and reduce mechanical stress at start-up while keeping setup and configuration minimal — a practical option for procurement teams seeking a low-complexity motor soft starter for common industrial motor starting applications. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 22 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e 7.5 – 11 kW\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 380 – 415 V AC (three-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Reduced-voltage soft starting\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS01N222QN?\u003c\/h4\u003e \u003cp\u003eThe ATS01N222QN is rated for 22 A operational current.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS01N222QN support?\u003c\/h4\u003e \u003cp\u003eThis model is specified for three-phase 380–415 V AC supplies.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes is the ATS01N222QN suitable for?\u003c\/h4\u003e \u003cp\u003eTypical motor compatibility is in the 7.5–11 kW range, depending on motor nameplate ratings and supply voltage.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs the ATS01N222QN intended for complex drive or simple starting applications?\u003c\/h4\u003e \u003cp\u003eThe ATS01N222QN is designed for basic soft starting in standard industrial applications (pumps, fans, compressors) rather than advanced drive or process-control use.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283600155,"sku":"ATS01N222QN","price":185.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n222qn-ats01-to-415v-ac_45cb84e8-730f-4b7c-a309-225b4677acb2.jpg?v=1777185283"},{"product_id":"schneider-electric-ats01n232qn-ats01","title":"ATS01N232QN, ATS01 Series Soft Starter, 15 kW, 32 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS01N232QN\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS01N232QN (Altistart 01) is a compact DIN-rail soft starter for three-phase asynchronous motors. It is rated for 32 A starter current and specified for motor power up to 15 kW on a 380–415 V supply (50–60 Hz). The unit uses a voltage-ramp start method with a built-in bypass contactor to reduce heat dissipation during run and to limit power loss after starting. Designed for simple machines — pumps, fans, conveyors and compressors — the ATS01N232QN offers a narrow 45 mm width for tight panels, an LED status display for basic diagnostics, and IP20 protection for control cabinet installation. The model does not include integrated motor overload protection and is intended where a basic, low‑cost soft start solution with minimal configuration is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 32 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e up to 15 kW (three-phase) at 380–415 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 380…415 V (50–60 Hz)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Start with voltage ramp\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor size can the ATS01N232QN start?\u003c\/h4\u003e \u003cp\u003eThe ATS01N232QN is specified for motors up to 15 kW on a 380–415 V three-phase supply.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltage and frequency does this model support?\u003c\/h4\u003e \u003cp\u003eRated supply voltage is 380…415 V and the unit supports 50–60 Hz operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N232QN include overload protection for the motor?\u003c\/h4\u003e \u003cp\u003eNo. This model does not include integrated motor overload protection and requires external protection if needed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs there a bypass contactor to reduce heat during running?\u003c\/h4\u003e \u003cp\u003eYes. The ATS01N232QN has an integrated bypass to reduce dissipation and noise after the start phase.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283796763,"sku":"ATS01N232QN","price":232.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n232qn-ats01-to-415v-ac_4a8b757f-2250-42cb-98a6-bab5755403c7.jpg?v=1777185288"},{"product_id":"schneider-electric-ats01n232rt-ats01","title":"ATS01N232RT, ATS01 Series Soft Starter, 15 kW, 32 A, 380 to 415V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS01 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS01N232RT\u003c\/h3\u003e \u003cp\u003e The Schneider ATS01N232RT is a compact three-phase motor soft starter rated for 32 A continuous current and intended for 460–480 V AC supply systems. According to Schneider-authorized datasheets and distributor listings, this model is typically applied on motors up to approximately 20 HP (three-phase at 460–480 V), making it suitable for medium-duty pumps, fans and compressors where controlled torque during acceleration reduces mechanical stress and inrush current. The ATS01N232RT uses a voltage-ramp start method with adjustable start and stop times (1 to 10 seconds) and a selectable starting torque range (approximately 30–80% of direct-on-line torque). The unit includes an internal bypass, an IP20 protection rating, basic discrete control inputs and status outputs, and is designed for straightforward, low‑configuration industrial motor starting where simple, reliable soft start functionality is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 32 A.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Up to ~20 HP (3-phase at 460–480 V).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 460…480 V AC (nominal).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Voltage ramp start (adjustable ramp 1–10 s).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Yes (integrated bypass).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e No integrated overload protection specified on distributor data (basic motor control and start\/stop functions).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Not specified \/ no fieldbus interfaces listed.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20.\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltage does the ATS01N232RT require?\u003c\/h4\u003e \u003cp\u003eThe ATS01N232RT is specified for 460–480 V AC three-phase supply operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor size can I start with this model?\u003c\/h4\u003e \u003cp\u003eDistributor and datasheet listings indicate suitability for motors up to about 20 HP at 460–480 V (approximate maximum based on rated current 32 A).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I adjust start and stop times on the ATS01N232RT?\u003c\/h4\u003e \u003cp\u003eYes — start and stop ramp times are adjustable, typically from 1 to 10 seconds as documented by Schneider-authorized sources.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS01N232RT include an internal bypass and motor overload protection?\u003c\/h4\u003e \u003cp\u003eThe unit includes an internal bypass. Distributor data indicate no integrated motor overload protection is provided — external protection is recommended where required.\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283862299,"sku":"ATS01N232RT","price":241.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats01n232rt-ats01-to-415v-ac_8af3bcb8-3daf-4c33-a612-03653f7c3127.jpg?v=1777185292"},{"product_id":"schneider-atsu01n206lt-atsu01-6a-soft-starter","title":"Schneider Electric ATSU01N206LT ATSU01 3P 6A 200-480V 0.75-3kW Altistart Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATSU01N206LT is a 3-phase electronic soft starter from the Altistart ATSU01 series, designed to provide smooth reduced-voltage starting and stopping for AC induction motors rated 0.75 to 3kW. The ATSU01 delivers controlled torque ramp-up, limiting inrush starting current and mechanical stress on driven equipment across a wide supply voltage range of 200 to 480V AC. Ideal for pump, fan, and conveyor applications where gentle motor acceleration is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01N206LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltistart U01 (ATSU01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 to 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 to 3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Systems:\u003c\/strong\u003e Eliminates water hammer and pressure surges on start by controlling ramp-up of starting current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFans \u0026amp; Blowers:\u003c\/strong\u003e Reduces mechanical stress on belts and couplings during acceleration with torque control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyors:\u003c\/strong\u003e Prevents load shifting and belt slip through smooth, configurable motor start sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressors:\u003c\/strong\u003e Limits inrush current peaks, protecting upstream switchgear and supply infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Industrial Machinery:\u003c\/strong\u003e Suitable for any 0.75–3kW 3-phase AC motor application requiring electronic soft starting and reduced voltage starting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230283960603,"sku":"ATSU01N206LT","price":333.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-atsu01n206lt-atsu01-altistart-soft-starter_1d1dc1ca-8a0e-4c97-8b84-b4de8689743d.jpg?v=1777163866"},{"product_id":"schneider-atsu01n212lt-atsu01-12a-3p-soft-starter","title":"Schneider Electric ATSU01N212LT ATSU01 3P 12A 200-480V 2.2-5.5kW Altistart 01 Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATSU01N212LT is a 3-phase electronic soft starter from the Altistart 01 (ATSU01) series, rated at 12A for motors from 2.2 to 5.5kW across a wide supply voltage range of 200 to 480V AC. Designed for engineers and procurement professionals who need reliable reduced-voltage motor starting, the ATSU01 delivers smooth torque control and reduced inrush current, protecting motors and driven machinery during acceleration and deceleration cycles.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01N212LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltistart 01 (ATSU01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 to 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 to 5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Starting:\u003c\/strong\u003e The ATSU01 soft starter limits starting current and mechanical shock, extending the service life of pumps, fans, and compressors driven by three-phase induction motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Conveying Systems:\u003c\/strong\u003e Gradual ramp-up prevents belt slippage and mechanical stress, making this motor soft starter ideal for conveyors and material-handling equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Equipment:\u003c\/strong\u003e Reduced voltage starting protects HVAC motors from high inrush current, reducing energy costs and wear on contactors and switchgear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Any 3-phase motor application in the 2.2–5.5 kW range benefits from the electronic soft starter's torque control and motor protection features.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the supply voltage range of the ATSU01N212LT?\u003c\/strong\u003e The ATSU01 operates on a 3-phase supply of 200 to 480V AC, making it suitable for both 230V and 400–480V industrial networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat motor sizes does this soft starter support?\u003c\/strong\u003e The ATSU01N212LT is rated for motors from 2.2 kW up to 5.5 kW at 12A continuous current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does a soft starter differ from a variable speed drive?\u003c\/strong\u003e A soft starter provides reduced-voltage starting and stopping only; it does not vary motor speed during normal operation. A VFD controls speed continuously. For fixed-speed applications requiring gentle starting, the ATSU01 is the cost-effective choice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the ATSU01 be used with a bypass contactor?\u003c\/strong\u003e Yes. Once the motor reaches full speed, an external bypass contactor can be used to shunt the soft starter, reducing heat dissipation and extending the device's service life.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284058907,"sku":"ATSU01N212LT","price":175.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-atsu01n212lt-atsu01-01-soft-starter_6e756ec8-d273-4c6d-8358-11d6a6f1b7bb.jpg?v=1777163870"},{"product_id":"schneider-atsu01n222lt-atsu01-22a-soft-starter","title":"Schneider Electric ATSU01N222LT ATSU01 3P 22A 200-480V 4-11kW Altistart Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATSU01N222LT is an Altistart ATSU01 series 3-phase electronic soft starter rated at 22A and 200–480V AC, designed to deliver smooth reduced-voltage motor starting for applications requiring controlled ramp-up, lower inrush current, and motor protection. The ATSU01 provides reliable torque control and starting current management for motors from 4 to 11kW, making it an efficient solution for pumps, fans, compressors, and conveyor drives.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATSU01N222LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltistart U01 (ATSU01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 to 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Fan Drives:\u003c\/strong\u003e Reduces mechanical stress and starting current surges in centrifugal pump and fan applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressors:\u003c\/strong\u003e Enables controlled ramp-up to minimise torque shock on compressor drive trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Smooth motor acceleration protects belts, gears, and mechanical couplings from high inrush torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Ideal for air handling units and chiller motors where soft starting extends equipment lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Industrial Machinery:\u003c\/strong\u003e Suitable for any 3-phase motor application from 4 to 11kW requiring reduced voltage starting and motor protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the rated current of the ATSU01N222LT?\u003c\/h3\u003e\u003cp\u003eThe ATSU01N222LT is rated at 22A, suitable for 3-phase motors up to 11kW at 480V AC.\u003c\/p\u003e\u003ch3\u003eWhat voltage range does the ATSU01 soft starter support?\u003c\/h3\u003e\u003cp\u003eThe ATSU01 operates across a supply voltage range of 200 to 480V AC, making it compatible with both 200V and 400\/480V industrial power systems.\u003c\/p\u003e\u003ch3\u003eWhat motor power range is supported?\u003c\/h3\u003e\u003cp\u003eThe ATSU01N222LT supports motors from 4kW up to 11kW depending on supply voltage.\u003c\/p\u003e\u003ch3\u003eWhat are the key benefits of using an ATSU01 soft starter?\u003c\/h3\u003e\u003cp\u003eThe ATSU01 reduces starting current (inrush), controls ramp-up torque, minimises mechanical stress on driven equipment, and helps protect the motor and connected machinery during start and stop cycles.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284124443,"sku":"ATSU01N222LT","price":218.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-atsu01n222lt-atsu01-altistart-soft-starter_0e718534-929c-4077-96ac-cc9a77549879.jpg?v=1777163874"},{"product_id":"schneider-electric-ats22c11q-altistart-22","title":"ATS22C11Q, Altistart 22 Series Soft Starter, 55 kW, 110 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C11Q\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS22C11Q (Altistart 22) is a compact 3‑phase motor soft starter rated for 110 A nominal. Verified manufacturer data specifies motor power capability up to 39 kW at 230 V and up to 55 kW at 400–440 V, making this unit suitable for common industrial motor sizes used on pumps, fans, compressors and simple conveyor systems. The ATS22C11Q supports a wide supply voltage range (230…440 V AC, 50\/60 Hz) and provides torque-controlled, current-limited starts (start current limited to approximately 3.5 × In) to reduce mechanical stress and limit inrush current. The model includes an internal bypass to reduce heat dissipation after starting, built-in motor monitoring with electronic overload \/ motor thermal model and a PTC thermistor input for thermal protection, plus RS485 (Modbus) communication for basic fieldbus connectivity. In practice, this Schneider ATS22 soft starter is a straightforward choice where reliable, compact industrial motor starting and simple monitoring are required in panel- or enclosure-mounted installations. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e110 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e39 kW at 230 V; 55 kW at 400–440 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC, 50\/60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited start (≈3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eElectronic overload; motor thermal model; PTC thermistor input\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS485 (Modbus)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284222747,"sku":"ATS22C11Q","price":1108.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c11q-ats22-to-440v-ac_6a08a5b3-3aa9-4442-a88d-4aa88db85038.jpg?v=1777185320"},{"product_id":"schneider-electric-ats22c11s6-altistart-22","title":"ATS22C11S6, Altistart 22 Series Soft Starter, 55 kW, 110 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C11S6\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22C11S6 is a compact motor soft starter rated for 110 A continuous operation and designed for 3-phase supply voltages from 230 to 600 V AC. Depending on system voltage, the ATS22C11S6 is suitable for motors up to approximately 30 kW at 230 V, 55 kW at 400–440 V and up to 75 kW at 500 V, making it appropriate for medium-power pumps, fans, compressors and conveyor drives used in industrial motor starting applications. This model incorporates an internal bypass to reduce heat dissipation during run, torque-control start (current-limited start up to approximately 3.5 × In) to limit inrush and protect mechanical systems, and integrated motor protection functions including overload and phase-failure detection. For system integration, the unit offers RS485\/Modbus communication and is compatible with SoMove configuration tools, simplifying commissioning and spare replacement. The ATS22C11S6 targets engineers and procurement teams seeking a straightforward, reliable soft starter to reduce mechanical stress, limit starting current and add basic motor protection without complex drive features. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e110 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e30 kW @ 230 V; 55 kW @ 400–440 V; 75 kW @ 500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230 – 600 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited start (≈3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection and phase-failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS485 (Modbus)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284288283,"sku":"ATS22C11S6","price":1378.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c11s6-ats22-to-600v-ac_5bc2d345-7073-4fe7-b81e-1939d671d0a5.jpg?v=1777185323"},{"product_id":"schneider-electric-ats22c14q-altistart-22","title":"ATS22C14Q, Altistart 22 Series Soft Starter, 75 kW, 140 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C14Q\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS22C14Q (Altistart 22) is a three-phase motor soft starter rated for supply voltages from 230 to 440 V (supply limits 195…484 V) and a rated operational current of 140 A (factory setting current 131 A). Verified motor power ratings for this SKU are 37 kW at 230 V (inline connection) and 75 kW at 400–440 V (inline connection); when wired in delta the family rating reaches up to 110 kW at 400 V. The unit uses torque-controlled (current-based) soft starting with a current-limited start mode (start with torque control, limited to 3.5 × In), which provides predictable, reduced inrush and controlled torque for pumps, fans, compressors and general material‑handling equipment. The ATS22C14Q includes an internal bypass to reduce heat dissipation and audible noise after the motor has started, and it provides basic integrated motor protection (motor overload protection) plus compatibility with SoMove\/serial configuration tools for quick setup and spare replacement. Designed for panel integration and standard industrial environments, it is specified for continuous operation up to a nominal ambient of 40 °C without derating. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e140 A (factory setting current 131 A)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e37 kW at 230 V (inline); 75 kW at 400–440 V (inline); up to 110 kW at 400 V (delta connection)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V (supply limits 195…484 V), 50–60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited start (start with torque control, limited to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection (basic motor protection)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eSoMove-compatible serial configuration (serial interface for configuration)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284386587,"sku":"ATS22C14Q","price":1588.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c14q-ats22-to-440v-ac_1823be45-ab78-42fd-a8e7-3193d0e32fc4.jpg?v=1777185327"},{"product_id":"schneider-electric-ats22c14s6u-altistart-22","title":"ATS22C14S6U, Altistart 22 Series Soft Starter, 75 kW, 10 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C14S6U\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22C14S6U is an Altistart 22 motor soft starter designed for three-phase industrial motor starting where robust current limiting and reduced mechanical stress are required. This SKU is rated for 140 A continuous operation and is suitable for supply voltages from 208 to 600 VAC (50\/60 Hz), making it appropriate for 230 V and 400 V systems commonly found in industrial plants. Typical motor compatibility includes up to approximately 75 kW (at 400 V) and around 37 kW (at 230 V), with vendor literature also listing typical horsepower ranges of roughly 40–125 hp depending on voltage. The ATS22C14S6U is intended for standard applications such as pumps, fans and conveyors where controlled starting torque and limited inrush current reduce mechanical wear and electrical network disturbance. Verified model features include an internal bypass to reduce heat loss during run, torque\/current-limited starting control for smoother acceleration, and integrated motor overload protection — practical benefits for maintenance teams and procurement looking to replace across common plant voltages without adding external protections. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e140 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e≈75 kW at 400 V; ≈37 kW at 230 V (typical values per manufacturer data)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e208 – 600 VAC (50\/60 Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque \/ current-limited start (current control)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284452123,"sku":"ATS22C14S6U","price":1757.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c14s6u-ats22-to-600v-ac_07b2172d-de94-45f2-ab59-bd8030aca452.jpg?v=1777185332"},{"product_id":"schneider-electric-ats22c17q-altistart-22","title":"ATS22C17Q, Altistart 22 Series Soft Starter, 90 kW, 170 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C17Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart 22 ATS22C17Q is a compact motor soft starter rated for 170 A nominal operational current and designed for three‑phase supplies in the 230–440 V range. It is specified to control motors up to approximately 45 kW on a 230 V supply and up to 90 kW on a 400–440 V supply (standard line connection ratings). The ATS22C17Q uses torque (current‑limited) start control — limiting starting current up to about 3.5 × In — which reduces mechanical stress and peak network loading compared with direct-on-line starts. This model includes an internal bypass contactor to reduce heat dissipation during run and an integrated motor overload protection function, making it appropriate for common industrial motor loads such as centrifugal pumps, fans, compressors and conveyor drives. \u003c\/p\u003e \u003cp\u003e Who this is for: procurement teams and engineers specifying reliable, compact soft starters for straightforward industrial motor starting tasks where controlled start torque, reduced inrush, and a built‑in bypass are required. Practical tip: select ATS22C17Q when you need a simple, robust soft starter for standard pump\/fan\/compressor applications up to the verified kW limits at the target supply voltage rather than a feature‑rich digital starter. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e170 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e45 kW (230 V) \/ 90 kW (400–440 V) — standard line connection ratings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque (current‑limited) start — current limited up to ~3.5 × In\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass contactor)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284550427,"sku":"ATS22C17Q","price":2034.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c17q-ats22-to-440v-ac_6f1709df-b191-4ef1-9ead-af9cb6b4f273.jpg?v=1777185336"},{"product_id":"schneider-electric-ats22c17s6-altistart-22","title":"ATS22C17S6, Altistart 22 Series Soft Starter, 90 kW, 170 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C17S6\u003c\/h3\u003e \u003cp\u003e The \u003cstrong\u003eATS22C17S6\u003c\/strong\u003e Altistart 22 soft starter is specified for a rated operational current of \u003cstrong\u003e170 A\u003c\/strong\u003e and supports motor power ratings across common industrial voltage classes: 45 kW at 230 V, 90 kW at 400–440 V, and up to 110 kW at 500 V. The unit is designed for three-phase supply voltages from \u003cstrong\u003e230 to 600 V\u003c\/strong\u003e (manufacturer limits typically shown as -15% \/ +10%), making it suitable for standard low- and medium-voltage industrial motor installations. Typical motor sizes covered by this model include medium-power pumps, fans and compressors in the 45–110 kW band depending on system voltage, so it is well matched to water-moving, ventilation and general mechanical loads where reduced inrush and controlled torque are required. This SKU implements \u003cstrong\u003etorque (current‑limited) starting\u003c\/strong\u003e — the starter limits starting current to approximately 3.5 × In — and includes an \u003cstrong\u003einternal bypass\u003c\/strong\u003e, which reduces thermal dissipation after the motor reaches running speed. Those verified features help lower mechanical stress during start, reduce energy losses during run, and simplify panel wiring and commissioning for procurement and engineering teams specifying reliable soft starters for industrial motor starting. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e170 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e45 kW @ 230 V; 90 kW @ 400–440 V; 110 kW @ 500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…600 V (manufacturer limits -15% \/ +10%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current limited to ~3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284615963,"sku":"ATS22C17S6","price":1713.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c17s6-ats22-to-600v-ac_5bfabfa3-d3b0-45c3-b062-2be15f5bc599.jpg?v=1777185340"},{"product_id":"schneider-electric-ats22c21q-altistart-22","title":"ATS22C21Q, Altistart 22 Series Soft Starter, 110 kW, 210 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C21Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22C21Q is a compact soft starter rated for 210 A (Ie) and designed for 230–440 V AC supplies. In inline (supply line) configuration it supports motors up to 55 kW at 230 V and up to 110 kW at 400–440 V; when used with the motor connected in delta the device supports higher motor ratings (up to 160 kW at 400 V, as specified for delta connection). Typical applications include centrifugal and piston pumps, fans, screw compressors, conveyors and other general-purpose industrial motor loads where limiting inrush current and reducing mechanical stress are priorities. Standout, verified features for the ATS22C21Q include an internal bypass contactor to reduce heat dissipation during run, torque (current‑limited) start control (start with torque control, current limited to 3.5 × In) for controlled acceleration, integrated motor overload protection, and compatibility with Schneider configuration tools (SoMove) for transfer of settings and quicker replacement. The unit is suited to procurement and engineering teams specifying a straightforward, robust motor soft starter for 3‑phase asynchronous motors in the 230–440 V class where a slim form factor and built‑in bypass simplify panel layout and reduce thermal footprint. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e210 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003eInline: 55 kW at 230 V; 110 kW at 400–440 V. Delta connection: up to 160 kW at 400 V.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230 – 440 V AC (device rated for 230–440 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass contactor)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current-limited start, up to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 (serial)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284714267,"sku":"ATS22C21Q","price":2489.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c21q-ats22-to-440v-ac_5dd77038-be3c-493a-a089-70e51e114c12.jpg?v=1777185344"},{"product_id":"schneider-electric-ats22c25q-altistart-22","title":"ATS22C25Q, Altistart 22 Series Soft Starter, 132 kW, 250 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C25Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22C25Q Altistart 22 is a line-mounted soft starter rated for 250 A nominal operation, designed for three‑phase industrial supplies. Its rated operating voltage is 230–440 V (supply limits 195–484 V), and it controls motors up to 75 kW at 230 V and up to 132 kW for inline (Ue) connection at 400–440 V; higher ratings apply when the motor is connected in delta (eg. 110 kW at 230 V delta, 220 kW at 400 V delta) as specified by Schneider. The ATS22C25Q uses torque (current‑based) control with a current limit behaviour (start current limited to about 3.5 × In) to manage inrush and deliver smooth acceleration, reducing mechanical stress on pumps, fans, compressors and material‑handling drives. Standout, verified features for this SKU include an integrated bypass to reduce heat dissipation during run, built‑in motor overload and thermal protections, and serial communication support (Modbus\/RS‑485) for basic remote status and monitoring. The device is intended for straightforward industrial motor starting where reliable current limiting, torque control and a compact, serviceable design are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e250 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e75 kW @ 230 V inline; 132 kW @ 400–440 V inline (also 110 kW @ 230 V delta; 220 kW @ 400 V delta)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003eRated 230–440 V (operating limits 195–484 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque (current‑based) control — start current limited to ~3.5 × In\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload and thermal protection; phase failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus \/ RS‑485\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284779803,"sku":"ATS22C25Q","price":2604.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c25q-ats22-to-440v-ac_7f5bdc36-1146-4450-8456-4ee7d0245e8e.jpg?v=1777185348"},{"product_id":"schneider-electric-ats22c25s6u-altistart-22","title":"ATS22C25S6U, Altistart 22 Series Soft Starter, 132 kW, 250 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C25S6U\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22C25S6U is a line-connected motor soft starter rated for 250 A continuous operation at 40 °C. It supports three-phase supply voltages from 208 V up to 600 V AC and is specified for motors up to 132 kW (at 400 V) or 75 kW (at 230 V) in standard switching configurations, making it suitable for medium- to large-size industrial motors such as pumps, fans, compressors and conveyor drives. This model uses torque (current-limited) start control to limit inrush current and manage starting torque (current-limited to a defined multiple of In), which reduces mechanical stress and electrical network disturbance during starting. Key verified features for the ATS22C25S6U include an internal bypass to reduce heat dissipation and acoustic noise during running, integrated motor overload protection, and a 110 V control supply option. Specify this soft starter when you need a compact, robust motor soft starter for industrial motor starting where controlled ramp-up, built-in bypassing and embedded motor protection are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e250 A (at 40 °C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e75 kW at 230 V; 132 kW at 400 V (standard switching)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e208 – 600 V AC (3-phase)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control (current-limited start)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284845339,"sku":"ATS22C25S6U","price":2501.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c25s6u-ats22-to-600v-ac_3d5200ea-8de0-4bb3-be8f-616d23f0b4fb.jpg?v=1777185353"},{"product_id":"schneider-electric-ats22c32q-altistart-22","title":"ATS22C32Q, Altistart 22 Series Soft Starter, 160 kW, 320 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C32Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22C32Q is a three-phase motor soft starter rated for 320 A (Ie) with a motor power capability up to 160 kW at 400–440 V and 90 kW at 230 V in standard line switching. It accepts a supply voltage range of 230...440 V AC (50\/60 Hz), making it suitable for common industrial voltage classes. Typical motor compatibility includes medium-to-large asynchronous squirrel-cage motors used on pumps, fans, compressors and conveyors where soft acceleration and reduced inrush current are required. The unit provides torque-controlled soft starting and stopping (current\/torque limiting), includes an internal bypass to reduce heat dissipation during run, and offers motor protection features such as overload protection and a PTC thermistor input for motor temperature monitoring. Communication and configuration options include an RS485 interface supporting Modbus, and the ATS22 range is compatible with SoMove configuration tools—features that simplify commissioning and integration into machine control panels. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e320 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e90 kW at 230 V; 160 kW at 400–440 V (standard switching)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230...440 V AC, 50\/60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque-controlled soft start \/ current limiting\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eOverload protection and PTC thermistor input for motor temperature monitoring\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS485 (Modbus)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230284910875,"sku":"ATS22C32Q","price":3279.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c32q-ats22-to-440v-ac_1124218c-d6ec-46e0-8384-c4221e7c60b6.jpg?v=1777185357"},{"product_id":"schneider-electric-ats22c41q-altistart-22","title":"ATS22C41Q, Altistart 22 Series Soft Starter, 220 kW, 410 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C41Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22C41Q Altistart 22 soft starter is specified for heavy-duty three-phase industrial motor starting with a nominal operational current of 410 A. It supports common supply voltages in industrial facilities (230…440 VAC, 50\/60 Hz) and is rated for motor powers up to 110 kW on 230 V and 220 kW on 400–440 V in standard configuration. This makes the ATS22C41Q suitable for medium to large asynchronous motors used in pumps, fans, compressors and conveyors where limiting inrush current and reducing mechanical stress are priorities. The unit implements torque\/current-limited starting (current-limited start up to ≈3.5 × In) and includes an internal bypass contact to reduce heat and losses after start‑up. For application-level use, the ATS22C41Q includes integrated motor protection functions (thermal overload model, thermistor\/PTC input, low-current and short-term overload detection) and offers field communication via Modbus where system integration or remote monitoring is required. These verified features make the ATS22C41Q a practical choice for procurement teams specifying a compact, straightforward motor soft starter for industrial motor control and reliable industrial motor starting. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e410 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e110 kW @ 230 V; 220 kW @ 400–440 V (standard connection)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC (50\/60 Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque \/ current-limited start (approx. 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass contact)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated thermal overload model; PTC\/thermistor input; low-current and momentary overload detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus (RTU)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285009179,"sku":"ATS22C41Q","price":4164.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c41q-ats22-to-440v-ac_88d6bae6-f38e-41f8-a82d-256f3e72341f.jpg?v=1777185361"},{"product_id":"schneider-electric-ats22c48q-altistart-22","title":"ATS22C48Q, Altistart 22 Series Soft Starter, 250 kW, 480 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C48Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22C48Q is an ATS22-series soft starter rated for heavy-duty industrial motor starting. It has a rated operational current of 480 A and is specified for motor power up to 132 kW at 230 V and up to 250 kW at 400 V \/ 440 V, making it suitable for large asynchronous (squirrel-cage) motors used in pumps, fans and other continuous-duty applications. The unit is designed for three-phase supply voltages in the 230…440 V range (supply limits typically cited as 195…484 V) and supports start control using torque\/current-limited starting (torque control with current limiting). Key practical features verified for this model include an integrated bypass contactor to minimise losses after start, built-in motor protection functions (thermal protection, overload and phase-failure detection), and communication capability (Modbus\/RS485 with RJ45 connector on standard configurations) for integration with PLC\/SCADA. ATS22C48Q is aimed at procurement and engineering teams who need a compact soft starter that handles high motor power, reduces mechanical stress and starting current, and integrates easily into industrial control systems. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e480 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e132 kW at 230 V; 250 kW at 400 V \/ 440 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V (supply limits reported 195…484 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited start (start with torque control, current limited to ~3.5·In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (integrated bypass contactor)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eThermal protection, overload protection, phase-failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus \/ RS485 (RJ45 connector reported on standard configurations)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285074715,"sku":"ATS22C48Q","price":4739.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c48q-ats22-to-440v-ac_60532e17-ee8a-4938-a883-81d250ef2117.jpg?v=1777185365"},{"product_id":"schneider-electric-ats22c59q-altistart-22","title":"ATS22C59Q, Altistart 22 Series Soft Starter, 315 kW, 590 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22C59Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22C59Q is a heavy-duty ATS22 series soft starter rated for a nominal operational current of 590 A (at 40 °C) and designed for three‑phase supply voltages in the 195–484 V range (commonly specified as 230–440 V AC, 50\/60 Hz). It supports motor power ratings including 160 kW at 230 V (standard connection) and 315 kW at 400 V (standard connection), with additional published power points for triangle\/star connections and alternate supply voltages. The unit provides torque control (current-limited starting) to limit inrush and mechanical stress during starts, and includes an internal bypass contactor to reduce heat dissipation and system losses once the motor is running. Integrated motor protection functions such as overload protection are provided, and the starter offers an RS‑485 communications interface for multipoint connection and configuration. Typical applications are pumps, fans, compressors and conveyor drives where controlled, current-limited starting and an internal bypass improve reliability, reduce mechanical wear, and simplify installation and replacement through compatibility with Schneider’s SoMove configuration tools. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e590 A (at 40 °C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e160 kW (230 V, standard connection); 315 kW (400 V, standard connection) — additional ratings published for triangle\/star connections\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e195–484 V (typically specified 230–440 V AC, 50\/60 Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited starting (current limited to specified multiple of In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass contactor)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 multipoint\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285173019,"sku":"ATS22C59Q","price":5724.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22c59q-ats22-to-440v-ac_a19517e1-3180-461a-8538-7fb361799128.jpg?v=1777185370"},{"product_id":"schneider-electric-ats22d17q-altistart-22","title":"ATS22D17Q, Altistart 22 Series Soft Starter, 7,5 kW, 17 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D17Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D17Q (Altistart 22) is a compact motor soft starter for 3‑phase supplies, rated for operation across the 230–440 V class. It is specified for a starter rating of 17 A with a factory set current of 14.8 A, supporting typical motor power ratings of 4 kW at 230 V and 7.5 kW at 400–440 V. Designed primarily for pumps and fans, the ATS22D17Q uses torque (current) control with a current limit of 3.5 In to reduce mechanical stress and limit inrush current during industrial motor starting. Standout, verified features for this SKU include an integrated bypass to reduce power dissipation in run, basic motor protection functions (thermal protection and phase-failure detection) and compact assembly with a heatsink for panel mounting. The ATS22D17Q is suitable for procurement when you need a straightforward, reliable solution for industrial motor starting where simple configuration, limited communication needs, and reduced starting torque are the main priorities. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e17 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e4 kW (230 V); 7.5 kW (400–440 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V (supply limits 195…484 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current limited to 3.5 In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (integrated bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eThermal protection (motor); phase-failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285304091,"sku":"ATS22D17Q","price":543.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d17q-ats22-to-440v-ac_b56a7da1-ba2b-4c97-a617-e7a798a9d37f.jpg?v=1777185374"},{"product_id":"schneider-electric-ats22d17s6-altistart-22","title":"ATS22D17S6, Altistart 22 Series Soft Starter, 7,5 kW, 17 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D17S6\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D17S6 is an Altistart 22 motor soft starter rated for a 17 A operational current and designed for three-phase supplies between 230 and 600 V. Its motor power compatibility covers typical small to medium-sized industrial motors: 4 kW at 230 V, 7.5 kW at 400–440 V and up to 9 kW at 500 V, making it suited for common pump, fan and compressor duties. The unit uses torque-controlled starting (current limited to 3.5×In) to reduce mechanical shock and limit inrush current, and includes an internal bypass to reduce heat dissipation during run. Built-in motor protection functions such as thermal protection and phase-failure detection help protect the motor and starter in standard industrial environments. Communication and configuration are supported via an RS‑485 \/ Modbus interface (RJ45), enabling parameter transfer and remote monitoring when integrated into plant control systems. With these features, the ATS22D17S6 is appropriate for procurement teams and engineers specifying compact soft starters for industrial motor starting where straightforward control, basic motor protection and reduced mechanical stress are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e17 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e4 kW @ 230 V; 7.5 kW @ 400–440 V; 9 kW @ 500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…600 V (rated)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control (current limited to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eThermal protection; phase-failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 (Modbus) via RJ45\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285533467,"sku":"ATS22D17S6","price":414.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d17s6-ats22-to-600v-ac_84f857ac-2564-4743-b141-36a481ee3f5e.jpg?v=1777185378"},{"product_id":"schneider-electric-ats22d32q-altistart-22","title":"ATS22D32Q, Altistart 22 Series Soft Starter, 15 kW, 32 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D32Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D32Q is an Altistart 22 motor soft starter rated at 32 A intended for three-phase supply systems. It supports typical motor power ratings of 7.5 kW on 230 V supply and 15 kW on 400–440 V supply, making it suitable for small to medium-sized pumps, fans, compressors and conveyors used in general industrial duty. The unit accepts a nominal supply voltage range of 230…440 V (with wider supply limits listed by the manufacturer) and uses torque control (current-limited start) to limit inrush and reduce mechanical stress during start-up. Notable, verified features for this SKU include an internal bypass to reduce dissipation during run, built-in motor and starter protection (phase failure and thermal protections), and a Modbus communication option for integration with automation systems. These characteristics make the ATS22D32Q a practical choice for procurement teams and engineers seeking a straightforward, compact motor soft starter for industrial motor starting where controlled starting torque, reduced starting current and basic communications are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e32 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e7.5 kW at 230 V; 15 kW at 400–440 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V (manufacturer supply limits noted)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current limited to 3.5 In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003ePhase failure detection; thermal protection for motor and starter\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285697307,"sku":"ATS22D32Q","price":598.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d32q-ats22-to-440v-ac_ab8f88aa-a2e5-4acc-95af-0769891d9382.jpg?v=1777185382"},{"product_id":"schneider-electric-ats22d32s6-altistart-22","title":"ATS22D32S6, Altistart 22 Series Soft Starter, 15 kW, 32 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D32S6\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D32S6 is an Altistart 22 motor soft starter rated for a nominal operational current of 32 A and designed for three-phase supply voltages from 230 V up to 600 V. Depending on supply voltage, the unit covers motors from 7.5 kW at 230 V up to 18.5 kW at 500 V (typical ratings: 7.5 kW @230 V; 15 kW @400–440 V; 18.5 kW @500 V). The ATS22D32S6 uses torque-controlled starting (current-limited to 3.5 × In) to provide a smooth, controlled ramp that limits inrush and mechanical stress—making it well suited to pumps, fans, compressors and light conveyor applications where reduced starting torque and controlled current are required. This model includes an internal bypass function to reduce power dissipation during run and support energy-efficient operation. Factory default current and protection settings are provided for quick commissioning, while discrete relay outputs and standard control-voltage inputs support straightforward integration into typical industrial control panels. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e32 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e7.5 kW @230 V; 15 kW @400–440 V; 18.5 kW @500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…600 V (three-phase)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current limited to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eInternal bypass (yes)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230285893915,"sku":"ATS22D32S6","price":668.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d32s6-ats22-to-600v-ac_29a4aba5-621a-4952-a845-422c20802d61.jpg?v=1777185386"},{"product_id":"schneider-electric-ats22d47q-altistart-22","title":"ATS22D47Q, Altistart 22 Series Soft Starter, 22 kW, 47 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D47Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22D47Q is a compact three‑phase motor soft starter rated 47 A (set current) and specified for motor power up to 22 kW on a 400\/440 V supply (11 kW at 230 V). It accepts a wide supply voltage range (230…440 V AC), making it suitable for common low-voltage industrial networks. Typical motor compatibility covers small to medium three‑phase asynchronous motors used on pumps, fans, compressors and conveyors where controlled starting and reduced inrush current are required. \u003cbr\u003e\u003cbr\u003e This SKU includes an internal bypass to reduce dissipation during run, an integrated heat‑sink assembly and features serial communication via Modbus over an RS‑485 link (RJ45 connector) for basic supervisory integration. Motor protection functions such as built‑in overload protection are provided to help protect the motor during start and run conditions. The ATS22D47Q is intended for straightforward industrial motor starting tasks where reliable soft starting, simplified wiring and basic communications are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e47 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e11 kW (230 V) \/ 22 kW (400–440 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus (RS‑485) with RJ45 connector\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286090523,"sku":"ATS22D47Q","price":635.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d47q-ats22-to-440v-ac_fe0a7ffa-6266-4578-a490-e2f24637e561.jpg?v=1777185390"},{"product_id":"schneider-electric-ats22d47s6-altistart-22","title":"ATS22D47S6, Altistart 22 Series Soft Starter, 22 kW, 47 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D47S6\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22D47S6 is a compact motor soft starter rated for 47 A nominal current and intended for three-phase supply voltages in the 230–600 V range. Depending on the supply voltage, the ATS22D47S6 supports typical motor ratings of 11 kW at 230 V, 22 kW at 400–440 V and up to 30 kW at 500 V, making it suitable for small to medium industrial motors driving pumps, fans, compressors and material handling equipment. This model provides controlled torque start (current-limited to approximately 3.5 × In) to limit inrush and reduce mechanical stress, and it includes an internal bypass to minimise heat dissipation during run. Factory-friendly features verified for this SKU include compatibility with Schneider’s SoMove configuration software, integrated motor overload and thermal monitoring along with phase-failure detection, and an RS‑485 communication interface for integration or remote monitoring. The ATS22D47S6 is designed for straightforward inline installation where smooth starts\/stops, reduced starting current and basic motor protection are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e47 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e11 kW @ 230 V; 22 kW @ 400–440 V; 30 kW @ 500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…600 V AC (rated)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control (current-limited start, ≈3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload and thermal protection; phase-failure and motor monitoring functions\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 (multipoint)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286254363,"sku":"ATS22D47S6","price":576.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d47s6-ats22-to-600v-ac_2b1e9923-81d6-4128-9e79-e8e94b3304c9.jpg?v=1777185394"},{"product_id":"schneider-electric-ats22d62q-altistart-22","title":"ATS22D62Q, Altistart 22 Series Soft Starter, 30 kW, 62 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D62Q\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D62Q is an Altistart 22 soft starter rated for a nominal line current of 62 A and designed for supply voltages from 230 to 440 V AC (50\/60 Hz). In typical installations it is sized for motors up to 15 kW at 230 V and up to 30 kW at 400–440 V, making it suitable for common industrial motor sizes used on pumps, fans, compressors and material‑handling equipment. The ATS22D62Q uses torque (current‑limited) start control — the starter limits inrush current (current limited to 3.5 × In) to deliver a controlled ramp and reduced mechanical stress — and includes an internal bypass to remove the power electronics from the circuit during steady‑state operation, reducing heat dissipation and losses. Factory settings place the device at 57 A, with the operating current adjustable to match the motor; the unit also provides built‑in motor overload protection and discrete I\/O for basic status and alarm signalling. For integration and remote monitoring the ATS22D62Q offers Modbus communication over RS‑485, which helps with quick commissioning and simple connection to supervisory systems. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e62 A.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e15 kW @ 230 V; 30 kW @ 400–440 V.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC, 50\/60 Hz (supply limits typically 195…484 V).\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque (current‑limited) start — current limited to 3.5 × In.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eModbus (RS‑485).\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286352667,"sku":"ATS22D62Q","price":934.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d62q-ats22-to-440v-ac_d2cdd30c-9dc0-40dc-8c4f-e92b947e996d.jpg?v=1777185399"},{"product_id":"schneider-electric-ats22d62s6-altistart-22","title":"ATS22D62S6, Altistart 22 Series Soft Starter, 30 kW, 62 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D62S6\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D62S6 is an Altistart 22 motor soft starter rated for a nominal operational current of 62 A (at 40 °C) and designed to control three-phase asynchronous motors. Its motor power ratings are specified as 15 kW at 230 V and 30 kW at 400 V, making it suitable for small to medium industrial motors in the indicated voltage classes. The ATS22D62S6 supports supply voltages across the 230–600 V range and offers torque-control (current-limited) starting to reduce mechanical stress and limit inrush current during motor acceleration. Typical applications include pumps, fans, compressors and conveyors where a controlled start\/stop and reduced mechanical wear are required. Standout, verified features for this SKU include an internal bypass switch to reduce heat and losses after start, integrated motor overload protection with PTC input support, and compatibility with configuration tools and communications (Modbus \/ serial interface) for faster setup and diagnostics. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e62 A (at 40 °C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e15 kW at 230 V; 30 kW at 400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230–600 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control \/ current-limited start (torque control)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated overload protection; PTC thermistor input supported\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eSerial \/ Modbus (RJ‑45 serial interface supported)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286483739,"sku":"ATS22D62S6","price":771.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d62s6-ats22-to-600v-ac_49a9994c-71c2-496a-a20d-f66d0b1d7ea8.jpg?v=1777185403"},{"product_id":"schneider-electric-ats22d75q-altistart-22","title":"ATS22D75Q, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D75Q\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS22D75Q is an Altistart 22 soft starter rated for 75 A continuous use and designed for three-phase supply voltages in the 230…440 V range (supply limits typically specified 195–484 V). It is factory-set to 69 A and is specified for typical motor power ratings of 18.5 kW at 230 V and 37 kW at 400–440 V, making it suitable for small to medium three‑phase induction motors used in pumps, fans, compressors and material‑handling equipment. The ATS22D75Q implements torque (current) control with current-limited starting (specified as current-limited to 3.5 × In), which reduces mechanical shock and limits inrush current during starts. Practical features verified for this SKU include an internal bypass to reduce heat and noise during run, integrated motor overload protection, and an RS‑485 multipoint communication interface for basic monitoring or configuration. Typical buyers are maintenance engineers and procurement teams specifying compact, convection‑cooled soft starters to replace direct-on-line starts or to add soft‑start functionality where simple, robust control and reduced mechanical wear are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e75 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e18.5 kW (230 V); 37 kW (400–440 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V (supply limits 195…484 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control — current-limited start (≈3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 multipoint\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286549275,"sku":"ATS22D75Q","price":841.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d75q-ats22-to-440v-ac_6930d107-77cb-4e86-a950-6df095510a63.jpg?v=1777185407"},{"product_id":"schneider-electric-ats22d75s6-altistart-22","title":"ATS22D75S6, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D75S6\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D75S6 is an Altistart 22 soft starter rated for a 75 A starter rating (factory setting 65 A) and intended for three-phase supply voltages across the 230–600 V class. It is specified to reliably start asynchronous motors up to 18.5 kW at 230 V, 37 kW at 400–440 V, and up to 45 kW at 500 V, making it suitable for medium-power pumps, fans and general-purpose industrial machinery. The ATS22D75S6 provides torque-controlled starting (current limited to 3.5 × In) to reduce mechanical stress and limit inrush current, and includes an internal bypass to reduce dissipation during run. For system integration it supports RS-485 serial communication (Modbus) and offers built-in motor protection functions including phase-failure detection and thermal protection features. Typical users are maintenance engineers and procurement teams specifying a compact, straightforward motor soft starter for industrial motor starting where pump and fan duty, simple configuration and reliable protection are required. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e75 A (starter rating) — factory setting 65 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e18.5 kW @ 230 V; 37 kW @ 400–440 V; 45 kW @ 500 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…600 V (rated supply voltage)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque control (current-limited start, up to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003ePhase-failure detection and thermal protection (motor and starter)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS-485 (Modbus)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286647579,"sku":"ATS22D75S6","price":803.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d75s6-ats22-to-600v-ac_50e4533b-6400-4493-8a2f-c683e4b292d0.jpg?v=1777185411"},{"product_id":"schneider-electric-ats22d75s6u-altistart-22","title":"ATS22D75S6U, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 600V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D75S6U\u003c\/h3\u003e \u003cp\u003e The Schneider ATS22D75S6U is an Altistart 22 motor soft starter rated for 75 A nominal operation (Ie) and intended for three-phase supplies in the 230–600 V range. Factory and distributor datasheets show typical motor power compatibility of 18.5 kW at 230 V and 37 kW at 400 V (inline connection), making this unit suitable for medium‑power motors commonly found on pumps, fans, compressors and material‑handling equipment. The device uses torque (current) control with a current‑limit start mode (listed as current limited to approx. 3.5×In) to limit starting current and manage torque during acceleration — a practical approach for applications that require reduced mechanical stress and controlled ramp-up. Verified product highlights include an internal bypass contactor to minimise heat dissipation during run, integrated motor overload protection, and compatibility with Schneider configuration tools (SoMove) for faster setup and spare replacement. The ATS22D75S6U is aimed at engineers and procurement teams seeking a compact, straightforward soft starter for standard industrial motor starting where smooth starts, reduced inrush and simple commissioning are priorities. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e75 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e18.5 kW (230 V) — 37 kW (400 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230 to 600 V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eTorque (current) control — current-limited start (≈3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003eIntegrated motor overload protection\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286745883,"sku":"ATS22D75S6U","price":785.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d75s6u-ats22-to-600v-ac_77157446-553c-40ee-8a32-89885e29a61a.jpg?v=1777185415"},{"product_id":"schneider-electric-ats22d88q-altistart-22","title":"ATS22D88Q, Altistart 22 Series Soft Starter, 45 kW, 88 A, 230 to 440V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS22 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required. \u003c\/p\u003e\n\u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS22D88Q\u003c\/h3\u003e \u003cp\u003e The Schneider Altistart ATS22D88Q is an ATS22-series motor soft starter rated for 88 A output (Ie) and sized for typical motor installations up to 45 kW at 400–440 V (and 22 kW at 230 V). It is designed for three-phase supply voltages from 230 to 440 V (supply limits 195–484 V) and is suited to standard industrial motor loads such as pumps, fans, compressors and conveyors. This model provides torque-controlled starting (start-with-torque with current limited to 3.5 × In) for improved handling of high‑torque or non-zero-voltage starts, and includes an internal bypass to reduce heat dissipation and audible noise during continuous running. ATS22D88Q also offers motor monitoring and protection features — including a PTC probe input for motor thermal sensing and integrated motor thermal protection — and supports communications via RS-485\/Modbus for remote monitoring and configuration (SoMove compatibility). Factory current setting is 81 A and the unit is intended for vertical mounting with forced convection cooling and operation up to 40 °C without derating. \u003c\/p\u003e\n\u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eRated operational current (Ie)\u003c\/th\u003e \u003ctd\u003e88 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor power range\u003c\/th\u003e \u003ctd\u003e22 kW at 230 V; 45 kW at 400–440 V (power range: 15–25 kW at 200–240 V; 30–50 kW at 380–440 V)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply voltage\u003c\/th\u003e \u003ctd\u003e230…440 V AC (supply limits 195–484 V), 50\/60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eControl method\u003c\/th\u003e \u003ctd\u003eStart with torque control (current limited to 3.5 × In)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBuilt-in bypass\u003c\/th\u003e \u003ctd\u003eYes (internal bypass)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor protection functions\u003c\/th\u003e \u003ctd\u003ePTC probe input (750 Ω); integrated motor thermal protection and motor monitoring functions (block detection, overload monitoring)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCommunication interfaces\u003c\/th\u003e \u003ctd\u003eRS‑485 multidrop (Modbus); RJ45 connector; compatible with SoMove\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230286811419,"sku":"ATS22D88Q","price":741.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats22d88q-ats22-to-440v-ac_c84cc49c-a7fb-4c0c-9d87-690b7ab9e0af.jpg?v=1777185420"},{"product_id":"schneider-electric-ats480c11y-110a-soft-starter","title":"Schneider Electric ATS480C11Y Altivar ATS480 110 A 208-690 V 55 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C11Y is an Altivar ATS480 soft starter rated for 110 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 88 A, and at 400 V it starts motors up to 55 kW in normal duty (45 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C11Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 x 247 x 290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C11Y is sized for the 55 kW normal-duty \/ 45 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 88 A, or the next size up if it exceeds 110 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287073563,"sku":"ATS480C11Y","price":1451.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c11y-ats480-soft-starter.jpg?v=1790305036"},{"product_id":"schneider-electric-ats480c14y-140a-soft-starter","title":"Schneider Electric ATS480C14Y Altivar ATS480 140 A 208-690 V 75 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C14Y is an Altivar ATS480 soft starter rated for 140 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 110 A, and at 400 V it starts motors up to 75 kW in normal duty (55 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C14Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089083\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x 272 x 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C14Y is sized for the 75 kW normal-duty \/ 55 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 110 A, or the next size up if it exceeds 140 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287171867,"sku":"ATS480C14Y","price":1790.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c14y-ats480-soft-starter.jpg?v=1790305044"},{"product_id":"schneider-electric-ats480c17y-170a-soft-starter","title":"Schneider Electric ATS480C17Y Altivar ATS480 170 A 208-690 V 90 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C17Y is an Altivar ATS480 soft starter rated for 170 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 140 A, and at 400 V it starts motors up to 90 kW in normal duty (75 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C17Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x 272 x 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C17Y is sized for the 90 kW normal-duty \/ 75 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 140 A, or the next size up if it exceeds 170 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287237403,"sku":"ATS480C17Y","price":2198.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c17y-ats480-soft-starter.jpg?v=1790305051"},{"product_id":"schneider-electric-ats480c21y-210a-soft-starter","title":"Schneider Electric ATS480C21Y Altivar ATS480 210 A 208-690 V 110 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C21Y is an Altivar ATS480 soft starter rated for 210 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 170 A, and at 400 V it starts motors up to 110 kW in normal duty (90 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C21Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 x 277 x 380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C21Y is sized for the 110 kW normal-duty \/ 90 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 170 A, or the next size up if it exceeds 210 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287302939,"sku":"ATS480C21Y","price":2469.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c21y-ats480-soft-starter.jpg?v=1790305059"},{"product_id":"schneider-electric-ats480c25y-250a-soft-starter","title":"Schneider Electric ATS480C25Y Altivar ATS480 250 A 208-690 V 132 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C25Y is an Altivar ATS480 soft starter rated for 250 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 210 A, and at 400 V it starts motors up to 132 kW in normal duty (110 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C25Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 x 277 x 380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C25Y is sized for the 132 kW normal-duty \/ 110 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 210 A, or the next size up if it exceeds 250 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287401243,"sku":"ATS480C25Y","price":2652.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c25y-ats480-soft-starter.jpg?v=1790305067"},{"product_id":"schneider-electric-ats480c32y-320a-soft-starter","title":"Schneider Electric ATS480C32Y Altivar ATS480 320 A 208-690 V 160 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C32Y is an Altivar ATS480 soft starter rated for 320 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 250 A, and at 400 V it starts motors up to 160 kW in normal duty (132 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C32Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 x 277 x 380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C32Y is sized for the 160 kW normal-duty \/ 132 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 250 A, or the next size up if it exceeds 320 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287499547,"sku":"ATS480C32Y","price":3329.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c32y-ats480-soft-starter.jpg?v=1790305074"},{"product_id":"schneider-electric-ats480c41y-410a-soft-starter","title":"Schneider Electric ATS480C41Y Altivar ATS480 410 A 208-690 V 220 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C41Y is an Altivar ATS480 soft starter rated for 410 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 320 A, and at 400 V it starts motors up to 220 kW in normal duty (160 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C41Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 314 x 670 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C41Y is sized for the 220 kW normal-duty \/ 160 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 320 A, or the next size up if it exceeds 410 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287630619,"sku":"ATS480C41Y","price":4027.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c41y-ats480-soft-starter.jpg?v=1790305082"},{"product_id":"schneider-electric-ats480c48y-480a-soft-starter","title":"Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C48Y is an Altivar ATS480 soft starter rated for 480 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 410 A, and at 400 V it starts motors up to 250 kW in normal duty (220 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C48Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 314 x 670 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C48Y is sized for the 250 kW normal-duty \/ 220 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 410 A, or the next size up if it exceeds 480 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287696155,"sku":"ATS480C48Y","price":4753.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c48y-ats480-soft-starter.jpg?v=1790305089"},{"product_id":"schneider-electric-ats480c59y-590a-soft-starter","title":"Schneider Electric ATS480C59Y Altivar ATS480 590 A 208-690 V 315 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C59Y is an Altivar ATS480 soft starter rated for 590 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 480 A, and at 400 V it starts motors up to 315 kW in normal duty (250 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C59Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e590 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 314 x 670 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C59Y is sized for the 315 kW normal-duty \/ 250 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 480 A, or the next size up if it exceeds 590 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287892763,"sku":"ATS480C59Y","price":5523.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c59y-ats480-soft-starter.jpg?v=1790305097"},{"product_id":"schneider-electric-ats480c66y-660a-soft-starter","title":"Schneider Electric ATS480C66Y Altivar ATS480 660 A 208-690 V 355 kW Soft Starter","description":"\u003cp\u003eThe Schneider Electric ATS480C66Y is an Altivar ATS480 soft starter rated for 660 A continuous current in normal duty at 40°C, across the 208-690 V three-phase supply range. Its heavy-duty rating is 590 A, and at 400 V it starts motors up to 355 kW in normal duty (315 kW heavy duty). Torque control (TCS) manages acceleration and deceleration, and Class 10E motor overload protection is built in, with stopping handled by dynamic braking and DC injection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS480C66Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606481089168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current (Ie) – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Current – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e590 A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Normal Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power at 400 V – Heavy Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting (5 x Ie max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150-700% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial, 1 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs \/ Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 314 x 670 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eCCS\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-2\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-2\u003c\/li\u003e\n\u003cli\u003eIEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ATS480C66Y is sized for the 355 kW normal-duty \/ 315 kW heavy-duty motor band at 400 V; pick a lower-current sibling if the motor's continuous demand is below 590 A, or the next size up if it exceeds 660 A in normal duty. Wiring it to the motor delta terminals instead of the supply line lets the same frame handle a larger motor by reducing the current the starter itself carries. Where the application involves high-inertia loads, the built-in dynamic braking and DC injection stop the motor without an external braking resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ATS480 series starts and stops asynchronous motors in process and infrastructure equipment – pumps, fans, compressors and conveyors – and shares its communication modules, display terminals and remote mounting kit with the Altivar drive range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287958299,"sku":"ATS480C66Y","price":6290.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c66y-ats480-soft-starter.jpg?v=1790305105"}],"url":"https:\/\/stoklink.com\/collections\/schneider-altistart.oembed?page=5","provider":"Stoklink","version":"1.0","type":"link"}