{"title":"Relays","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eComprehensive Relay Solutions: Protection, Control, and Overload Relay Devices\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe electrical relay is a cornerstone of industrial and commercial control systems. Functioning as an electrically operated switch, a relay allows a low-power control signal to safely and remotely manage a high-power circuit. This separation between the control and power circuits is fundamental to automation, protection, and logic operations across every sector, from machine building and building management to energy infrastructure. At Stoklink, we feature a diverse range of electrical relay units, including specialized Protection Relay and Overload Relay solutions from industry leaders like ABB Relay and Schneider Relay.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eCore Functionality of the Electrical Relay in Control and Automation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRelays are primarily categorized by their function: general-purpose switching (\u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"Control Relay\"\u003e\u003cspan\u003eControl Relay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e) or specialized safety functions (Protection Relay). Each category plays a distinct but critical role in maintaining system integrity and operational efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eControl Relay: The Brain of Logic Circuits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Control Relay handles the signaling and logic within a control panel. These devices are typically used to multiply contacts, interface between different voltage levels (e.g., 24V DC logic controlling 230V AC solenoids), and provide interlocking functions for motor control or sequential processes. A standard control relay features an electromagnetic coil that, when energized, physically moves an armature to close or open a set of contacts. Their reliability and speed are essential for high-frequency switching tasks in modern Programmable Logic Controller (PLC) systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eProtection Relay: Ensuring System Integrity and Safety\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"Protection Relay\"\u003e\u003cspan\u003eProtection Relay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e is designed to monitor system parameters (current, voltage, temperature) and trip the power circuit when predefined fault conditions are detected. This group includes critical devices such as the Overload Relay and thermal monitoring relays. The Overload Relay monitors motor current and trips the contactor circuit if the current exceeds safe limits for an extended period, preventing costly motor burnout due to excessive mechanical load. Reliable motor protection starts with selecting a highly accurate thermal or electronic overload relay.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eSpecialized Relay Types: Overload Relay and Time Delay Relay\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModern control systems frequently require relays that incorporate time-based or fault-sensing intelligence beyond simple ON\/OFF switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOverload Relay: Crucial for Motor Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"Overload Relay\"\u003e\u003cspan\u003eOverload Relay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e is typically paired directly with a contactor to form a motor starter. Its function is crucial for preventing motor winding damage caused by prolonged overcurrent draw. Modern electronic overload relays offer precision trip settings and faster response times than older thermal types. Choosing the right Overload Relay ensures the motor runs reliably near its maximum capacity without compromising its thermal lifespan.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eTime Delay Relay: Adding Logic to Sequencing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA Time Delay Relay is indispensable in automation for controlling the sequence and timing of events. These relays, also known as timers, allow contacts to switch only after a specified time interval, either upon energization (On-Delay) or de-energization (Off-Delay). The Time Delay Relay enables smooth transitions in complex processes, such as staggering the start of multiple motors to reduce peak demand or ensuring components operate in the correct order. This precision in timing is vital for consistent machine operation and process quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eLeading Relay Brands: ABB Relay and Schneider Relay for Reliability\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eReliability is non-negotiable for control and protection devices. We partner with the industry’s most trusted manufacturers to bring you the best-in-class electrical relay technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eABB Relay Solutions:\u003c\/span\u003e\u003cspan\u003e The \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"ABB Relay\"\u003e\u003cspan\u003eABB Relay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e portfolio encompasses everything from miniature interface relays to advanced electronic safety and monitoring relays. ABB's focus on compact design and robust terminal technology ensures ease of wiring and long-term durability in crowded control panels. Their safety relays are integral to modern machine safety standards, providing dependable monitoring of emergency stop circuits and safety guards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSchneider Relay Performance:\u003c\/span\u003e\u003cspan\u003e The Schneider Relay range, including the popular Zelio and TeSys series, provides a wide selection of control and Protection Relay units. Schneider Relay products are recognized for their modularity, enabling easy configuration of auxiliary blocks and integration with contactors and motor starters. This modular approach simplifies inventory management and speeds up panel assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eSelecting the Ideal Electrical Relay for Your Application\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen selecting an electrical relay, consider the following key technical parameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCoil Voltage:\u003c\/span\u003e\u003cspan\u003e The control voltage (e.g., 24V DC, 120V AC) required to energize the relay's coil.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eContact Configuration:\u003c\/span\u003e\u003cspan\u003e The number of poles and the type of contacts (Normally Open\/Normally Closed) required for the circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCurrent Rating:\u003c\/span\u003e\u003cspan\u003e The maximum current the contacts can safely switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSpecial Function:\u003c\/span\u003e\u003cspan\u003e Whether you need standard switching (Control Relay), thermal protection (Overload Relay), or time-based operation (Time Delay Relay).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBy carefully matching these requirements with our extensive selection, you can build automation and safety systems that are both effective and compliant. The combination of precision and reliability found in every ABB Relay and \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"Schneider Relay\"\u003e\u003cspan\u003eSchneider Relay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e ensures maximum operational uptime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eEnhance Control and Safety: Explore the Stoklink Relay Collection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/relay\" title=\"Relay\"\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e category offers the fundamental building blocks for precise control and safety in any modern electrical installation. From the essential Time Delay Relay governing sequencing, to the crucial Overload Relay protecting valuable motor assets, and specialized Protection Relay units, our inventory provides certified components from industry-leading brands. You can invest in the best electrical relay technology to enhance the performance, safety, and reliability of your entire control system.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"abb-2cds200946r0002-s2c-h6-20r-auxiliary-contact","title":"ABB 2CDS200946R0002 S2C-H6-20R 2NO Auxiliary Contact for Distribution Board Devices 1W","description":"\u003cp\u003eThe ABB S2C-H6-20R (SKU: 2CDS200946R0002) is a 2NO auxiliary contact designed as an auxiliary device for distribution board devices, delivering reliable status signalling and interlocking in industrial control panels. Part of ABB's S2C series, the S2C-H6-20R operates at 1 W and features a compact 8.8 mm × 85 mm profile weighing just 0.04 kg, making it ideal for space-constrained distribution board assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H6-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200946R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779697958\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NO (2 Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary device for distribution board devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 235 \/ GB\/T 14048.5 \/ IEC\/EN 60947-5-1 \/ UL 1077:\u003c\/strong\u003e Certified to combined North American and international standards for low-voltage control devices and supplementary protectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Compliant with European standard for low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for industrial electrical equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229017903387,"sku":"2CDS200946R0002","price":12.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200946r0002-s2c-h6-20r-board-devices-1w_3bd48b00-2b72-4de2-8d69-9c74d74dc47f.webp?v=1777160980"},{"product_id":"abb-2taz312000r2041-e290-16-10-24-latching-relay","title":"ABB 2TAZ312000R2041 E290-16-10\/24 16A 1NO DIN Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-10\/24 (SKU: 2TAZ312000R2041) is a 16A electromechanical latching relay designed for DIN rail mounting in control panels and building automation systems. The E290-16-10\/24 features a 1NO contact configuration and compact 18mm wide housing, making it ideal for space-constrained installation. Weighing just 114g and measuring 18mm × 85mm × 62mm, this relay delivers reliable bistable switching performance compliant with IEC\/EN 60669-2-2.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-10\/24\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2041\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2-2:\u003c\/strong\u003e Switches for household and similar fixed installations — particular requirements for electromechanical latching relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e International standard for household fixed electrical installation switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household and similar fixed electrical switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for fixed electrical installation switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN60669-2:\u003c\/strong\u003e Part 2 particular requirements for household switches and relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability tests\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60669-1:\u003c\/strong\u003e European standard for switches in household and similar fixed electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60669-2:\u003c\/strong\u003e European particular requirements for household switches and relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, no restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e German Association for Electrical, Electronic \u0026amp; Information Technologies certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilding automation and smart home control systems\u003c\/li\u003e\n  \u003cli\u003eLighting control and load switching in control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC and energy management installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and machine control circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail assembly boards requiring compact bistable relay switching\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022064923,"sku":"2TAZ312000R2041","price":32.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2041-e290-16-10-24-abb-2taz312000r2041-e290-16-10-24_3c00d555-0196-4f31-9580-685c431a1818.webp?v=1777393319"},{"product_id":"abb-2taz312000r2031-e290-16-10-48-latching-relay","title":"ABB 2TAZ312000R2031 E290-16-10\/48 16A DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-10\/48 (SKU: 2TAZ312000R2031) is a 16 A electromechanical latching relay designed for DIN-rail mounting in control panels and building automation systems. Part of the ABB E290 Series, this latching relay retains its switched state without continuous coil power, making it ideal for energy-efficient switching and load control applications in industrial and commercial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-10\/48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939589\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2-2:\u003c\/strong\u003e Particular requirements for electromechanical remote-control switches (RCS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e International standard for household and similar fixed electrical installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household switches — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for remote-control, signal and motor-operated switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonised particular requirements for remote-control switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — independently tested and certified by VDE Germany\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting control circuits in commercial and industrial buildings\u003c\/li\u003e\n\u003cli\u003eStaircase and corridor time-delay switching systems\u003c\/li\u003e\n\u003cli\u003eHVAC and building management system (BMS) switching\u003c\/li\u003e\n\u003cli\u003eEnergy-saving load control where bistable (non-power-hungry) switching is required\u003c\/li\u003e\n\u003cli\u003eControl panel assembly and DIN-rail-mounted switching solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022130459,"sku":"2TAZ312000R2031","price":33.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2031-e290-16-10-48-abb-2taz312000r2031-e290-16-10-48_a6cd61ba-b4a6-4463-a28b-ed845c2db232.webp?v=1777393324"},{"product_id":"abb-2taz312000r2011-e290-16-10-230-latching-relay","title":"ABB 2TAZ312000R2011 E290-16-10\/230 16A DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-10\/230 (SKU: 2TAZ312000R2011) is a 16A electromechanical latching relay designed for DIN-Rail installation in control panels and building automation systems. The E290-16-10\/230 retains its switched state without continuous coil power, reducing energy consumption in sustained-on applications. Compact at 18mm × 85mm × 62mm and weighing just 114g, this relay fits easily into space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-10\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2-2:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — particular requirements for remote-control switches (RCS)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e International standard for household switches — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European standard for household switches — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN60669-1:\u003c\/strong\u003e Combined IEC\/EN compliance for household and similar switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN60669-2:\u003c\/strong\u003e Combined IEC\/EN compliance — particular requirements for switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60068-2:\u003c\/strong\u003e Environmental testing standard for electronic and electrical components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60669-1:\u003c\/strong\u003e European norm for fixed electrical installation switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN60669-2:\u003c\/strong\u003e European norm — particular requirements for switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and certified by Verband der Elektrotechnik (VDE), Germany\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022195995,"sku":"2TAZ312000R2011","price":18.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2011-e290-16-10-230-abb-2taz312000r2011-e290-16-10-230_ffec25d4-d7c9-4bc5-974f-999fd2e19032.webp?v=1777393336"},{"product_id":"abb-2taz322000r2011-e290-32-10-230-32a-latching-relay","title":"ABB 2TAZ322000R2011 E290-32-10\/230 32A 1-Pole DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-32-10\/230 (SKU: 2TAZ322000R2011) is a 32A single-pole electromechanical latching relay designed for DIN-rail mounting in control panels and building automation systems. Rated at 32A with a compact 18mm profile, the E290-32-10\/230 maintains its switched state without continuous coil energisation, reducing power consumption and heat generation in panel assemblies. Compliant with IEC\/EN 60669-1 and IEC\/EN 60669-2, this relay is engineered for reliable, energy-efficient switching in industrial and commercial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-32-10\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ322000R2011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household and similar fixed electrical switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for fixed electrical installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Switches for household and similar installations — particular requirements for latching switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for robustness and reliability verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonised standard for particular requirements for switches including latching types\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e CE marked — meets all applicable EU product safety and performance directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for the Great Britain market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified and tested by VDE, the German Association for Electrical, Electronic \u0026amp; Information Technologies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022261531,"sku":"2TAZ322000R2011","price":46.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz322000r2011-e290-32-10-230-abb-2taz322000r2011-e290-32-10-230_2def08fa-5393-46a9-8dff-3d926805129a.webp?v=1777393328"},{"product_id":"abb-2taz312000r2042-e290-16-20-24-latching-relay","title":"ABB 2TAZ312000R2042 E290-16-20\/24 16A DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-20\/24 (SKU: 2TAZ312000R2042) is a 16A electromechanical latching relay from the ABB E290 series, designed for DIN-Rail mounting in control panels and building automation systems. Featuring a compact 18mm wide footprint and a bistable latching mechanism, the E290-16-20\/24 maintains its switched state without continuous coil power, reducing energy consumption and ensuring position retention during power interruptions. Certified to IEC\/EN 60669-1 and IEC\/EN 60669-2, it is built for reliable long-term operation in industrial and commercial electrical installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-20\/24\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2042\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household and similar fixed electrical switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for fixed electrical installation switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements — electronic switches and related accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability verification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e EN harmonised compliance for installation switching devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e EN particular requirements for electronic and latching switching devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified by Verband der Elektrotechnik — German electrical engineering safety standard\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022327067,"sku":"2TAZ312000R2042","price":46.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2042-e290-16-20-24-abb-2taz312000r2042-e290-16-20-24_9e61b562-8623-49ae-9f6a-6c3bb0dde4aa.webp?v=1777393332"},{"product_id":"abb-2taz312000r2032-e290-16-20-48-latching-relay","title":"ABB 2TAZ312000R2032 E290-16-20\/48 16A DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-20\/48 (SKU: 2TAZ312000R2032) is a 16A electromechanical latching relay designed for DIN-rail mounting in control panels and building automation systems. Part of the ABB E290 series, this compact 18mm-wide latching relay maintains its switching state without continuous coil energisation, delivering energy-efficient bistable switching for lighting circuits, HVAC control, and industrial automation applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-20\/48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN certification for fixed electrical installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for remote-control switches (impulse relays)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonised standard for remote-control and impulse switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — authorised for sale in Great Britain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified by Verband der Elektrotechnik — German electrical safety certification\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLighting circuit control in residential, commercial, and industrial buildings\u003c\/li\u003e\n\u003cli\u003eHVAC and climate control systems requiring bistable switching\u003c\/li\u003e\n\u003cli\u003eBuilding management and home automation panels\u003c\/li\u003e\n\u003cli\u003eEnergy-saving applications where coil power must not be continuously consumed\u003c\/li\u003e\n\u003cli\u003eControl panels in industrial automation requiring compact DIN-rail components\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022425371,"sku":"2TAZ312000R2032","price":46.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2032-e290-16-20-48-abb-2taz312000r2032-e290-16-20-48_7afc2594-47ab-45db-ba66-4fa2944d9029.webp?v=1777393340"},{"product_id":"abb-2taz312000r2012-e290-16-20-230-latching-relay","title":"ABB 2TAZ312000R2012 E290-16-20\/230 16A DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-20\/230 (SKU: 2TAZ312000R2012) is a 16A electromechanical latching relay from the ABB E290 series, designed for DIN-rail mounting in control panels and industrial automation applications. Compact at just 18mm wide, this latching relay maintains its switched state without continuous coil energisation, reducing power consumption and heat generation in the panel. It carries CE, VDE, and RoHS certifications, making it suitable for demanding industrial and building automation environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-20\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e International standard for switches for household and similar fixed electrical installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised version of IEC 60669-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for fixed electrical installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Part 2 — particular requirements for latching switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for robustness and reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European standard compliance for electrical installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European compliance for particular switch types including latching relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, free from restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e European Chemicals Regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU safety and regulatory requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrotechnical association certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022490907,"sku":"2TAZ312000R2012","price":33.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2012-e290-16-20-230-abb-2taz312000r2012-e290-16-20-230_d2ecde3d-9579-47af-a2e4-d9929b758689.webp?v=1777393358"},{"product_id":"abb-2taz322000r2012-e290-32-20-230-latching-relay","title":"ABB 2TAZ322000R2012 E290-32-20\/230 32A 2-Pole DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-32-20\/230 (SKU: 2TAZ322000R2012) is a 32A 2-pole electromechanical latching relay designed for DIN-rail mounting in control panels and industrial automation applications. Part of ABB's E290 series, it delivers reliable switching performance with a compact 18mm profile, making it well-suited for space-constrained distribution boards and building automation systems. The E290-32-20\/230 maintains its switched position without continuous coil energisation, reducing power consumption and heat generation in demanding environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-32-20\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ322000R2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939787\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — product meets EU health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European adoption of IEC 60669-1 for switches in fixed electrical installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for household and similar fixed installation switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for latching switches and electronic switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard — ensures performance under temperature, humidity, and vibration conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European standard — particular requirements for latching switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper disposal and recycling compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain regulatory requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — independently tested and certified by the German electrical engineering association\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilding automation and HVAC control panels requiring bistable switching\u003c\/li\u003e\n\u003cli\u003eEnergy management systems where power-saving latching operation reduces standby consumption\u003c\/li\u003e\n\u003cli\u003eLighting control circuits in commercial and industrial facilities\u003c\/li\u003e\n\u003cli\u003eDIN-rail distribution boards in industrial automation and process control\u003c\/li\u003e\n\u003cli\u003eRemote switching applications where coil power is applied only momentarily\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229022556443,"sku":"2TAZ322000R2012","price":51.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz322000r2012-e290-32-20-230-abb-2taz322000r2012-e290-32-20-230_67a54684-61ba-4c1e-bad5-ff2f841fc967.webp?v=1777393344"},{"product_id":"abb-2taz312000r2033-e290-16-11-48-latching-relay","title":"ABB 2TAZ312000R2033 E290-16-11\/48 16A 1NO+1NC DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-11\/48 (SKU: 2TAZ312000R2033) is a 16 A electromechanical latching relay designed for DIN-Rail mounting in control panel and industrial automation applications. The E290-16-11\/48 features a 1NO+1NC contact configuration and maintains its switched state without continuous coil energisation, reducing power consumption and heat generation. Compact at 18 mm wide, it integrates easily into space-constrained distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-11\/48\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2033\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for switches — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for switch general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonised standard for switches — particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU product safety and performance directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified and tested to VDE (Verband der Elektrotechnik) standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eLighting control circuits requiring bistable (latching) switching in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation panels where power-saving relay operation is required\u003c\/li\u003e\n  \u003cli\u003eControl panel DIN-Rail assemblies with space constraints benefiting from the 18 mm form factor\u003c\/li\u003e\n  \u003cli\u003eHVAC, building management systems, and energy management installations\u003c\/li\u003e\n  \u003cli\u003eAny application demanding maintained contact position on loss of control power\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229023244571,"sku":"2TAZ312000R2033","price":44.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2033-e290-16-11-48-abb-2taz312000r2033-e290-16-11-48_d967e813-2095-488a-8de4-295aa51712c3.webp?v=1777393362"},{"product_id":"abb-2taz312000r2013-e290-16-11-230-latching-relay","title":"ABB 2TAZ312000R2013 E290-16-11\/230 16A 1NO+1NC 230V DIN-Rail Electromechanical Latching Relay","description":"\u003cp\u003eThe ABB E290-16-11\/230 (SKU: 2TAZ312000R2013) is a 16A electromechanical latching relay designed for DIN-rail mounting in control panels and building automation applications. Part of the ABB E290 series, the E290-16-11\/230 features a 1NO+1NC contact configuration with a 230V coil voltage, providing reliable bistable switching that retains its last position on power loss — ideal for energy-saving and fail-safe control circuits. Compact at just 18mm wide and weighing only 122g, it integrates seamlessly into space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290-16-11\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312000R2013\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromechanical Latching Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for switches for household and similar fixed electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Combined IEC and EN compliance for general switch requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for remote-control switches (RCS) and latching relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability testing standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European standard for remote-control switches and related devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant for sale in the EU and UK\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives and regulations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for the Great Britain market post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrotechnical safety certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilding automation and smart home control systems\u003c\/li\u003e\n  \u003cli\u003eLighting control circuits requiring bistable (memory) switching\u003c\/li\u003e\n  \u003cli\u003eEnergy management installations where power-off state retention is required\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003eStaircase lighting timers and centralised switching applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229024981275,"sku":"2TAZ312000R2013","price":24.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312000r2013-e290-16-11-230-abb-2taz312000r2013-e290-16-11-230_29732d94-15ae-457b-a21b-a0d68c27b01c.webp?v=1777393349"},{"product_id":"abb-2cca704300r0001-e292-16-20-latching-relay","title":"ABB 2CCA704300R0001 E292-16-20 16A DIN-Rail Main Contact Module Latching Relay","description":"\u003cp\u003eThe ABB E292-16-20 (SKU: 2CCA704300R0001) is a 16 A main contact module latching relay from the E290 Series, designed for DIN-rail installation in control panels and building automation systems. Compact at just 9 mm wide and weighing only 45 g, the E292-16-20 delivers reliable switching performance in space-constrained enclosures. It meets a comprehensive set of international standards including IEC\/EN 60669-1 and IEC\/EN 60669-2-2, making it suitable for demanding industrial and commercial electrical installations.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE292-16-20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCA704300R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE292-16-20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatching Relay \/ Main Contact Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm × 85 mm × 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2-2:\u003c\/strong\u003e Particular requirements for remote-control switches (RCS)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for switches in building electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrotechnical products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonised standard for household fixed switches — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonised particular requirements for building switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives and harmonised standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and certified by Verband der Elektrotechnik (VDE), Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilding automation and smart home control systems requiring latching relay functionality\u003c\/li\u003e\n  \u003cli\u003eLighting control panels and circuit switching in commercial and industrial installations\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mounted control enclosures where space-saving 9 mm width is critical\u003c\/li\u003e\n  \u003cli\u003eStaircase lighting timers, centralised load switching, and energy management systems\u003c\/li\u003e\n  \u003cli\u003eModular installation alongside other E290 series accessories for scalable control solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025177883,"sku":"2CCA704300R0001","price":22.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cca704300r0001-e292-16-20-abb-2cca704300r0001-e292-16-20_c62097e1-0496-41ea-860e-c8d4dab9d20a.webp?v=1777393353"},{"product_id":"abb-2taz312001r2013-e294-230-latching-relay","title":"ABB 2TAZ312001R2013 E294\/230 Central On-Off Control Module 1A DIN-Rail Latching Relay","description":"\u003cp\u003eThe ABB E294\/230 (SKU: 2TAZ312001R2013) is a Central On-Off Control Module latching relay from the E290 series, designed for centralized switching control in residential and commercial installation systems. Rated at 1 A and mounted on standard DIN-Rail, the E294\/230 enables remote on\/off control of lighting and load circuits with a compact 18 mm form factor suited for space-constrained distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE294\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2TAZ312001R2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE294\/230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatching Relay \/ Central On-Off Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-1:\u003c\/strong\u003e Switches for household and similar fixed electrical installations — General requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2-2:\u003c\/strong\u003e Particular requirements — Remote-control switches (RCS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Particular requirements for switches — supplementary standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — mechanical and climatic test methods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-1:\u003c\/strong\u003e European harmonized standard for household switches — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60669-2:\u003c\/strong\u003e European harmonized standard for switches — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricting use of hazardous materials in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant for responsible disposal and recycling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for sale in Great Britain post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — tested and certified by German electrotechnical standards body\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCentralized on\/off switching of lighting circuits in residential buildings, hotels, and offices\u003c\/li\u003e\n\u003cli\u003eIntegration into building automation and smart home control systems\u003c\/li\u003e\n\u003cli\u003eLoad control in commercial distribution boards requiring remote switching\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels where DIN-Rail mounted latching relays are specified\u003c\/li\u003e\n\u003cli\u003eEnergy management systems enabling zone-based switching from a central point\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025243419,"sku":"2TAZ312001R2013","price":52.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2taz312001r2013-e294-230-abb-2taz312001r2013-e294-230_7fc12d76-c044-41dd-ba2f-d08e264b6ccf.webp?v=1777393378"},{"product_id":"abb-2cca704340r0001-e299-11-installation-relay","title":"ABB 2CCA704340R0001 E299-11 1NO+1NC 250V AC Snap-On Installation Relay Auxiliary Contact","description":"\u003cp\u003eThe ABB E299-11 (SKU: 2CCA704340R0001) is a snap-on auxiliary contact installation relay rated at 250 V AC, delivering reliable 1NO+1NC switching in compact 18 × 85 × 58 mm dimensions. Weighing just 45 g and consuming only 0.1 W, the E299-11 is engineered for control panel integration, offering robust signal switching for industrial automation and building control applications with full compliance to IEC\/EN 60669-1 and IEC\/EN 60669-2 standards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE299-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCA704340R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE299\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstallation Relay (Auxiliary Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSnap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm × 85 mm × 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612270939985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union CE marking requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Certified to VDE German electrotechnical standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with RoHS amendment extending restricted substance list\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60669-1 \/ EN 60669-1:\u003c\/strong\u003e Meets international and European standard for switches for household and similar fixed electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60669-2:\u003c\/strong\u003e Compliant with particular requirements for remote-control switches and electronic switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAuxiliary signal switching in residential and commercial control panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems requiring compact snap-on relay components\u003c\/li\u003e\n  \u003cli\u003eBuilding management and HVAC control circuits\u003c\/li\u003e\n  \u003cli\u003eStatus feedback and interlocking circuits in distribution boards\u003c\/li\u003e\n  \u003cli\u003eLow-power auxiliary contact expansion for ABB E299 series installation relays\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025308955,"sku":"2CCA704340R0001","price":23.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cca704340r0001-e299-11-abb-2cca704340r0001-e299-11_445c5f75-6dd0-468c-9f38-6d4e0ffb6a8b.webp?v=1777393370"},{"product_id":"abb-2csm142120r1201-rd2-residual-current-monitoring-relay","title":"ABB 2CSM142120R1201 RD2 Type A 2000mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD2 (SKU: 2CSM142120R1201) is a Type A residual current monitoring relay designed to continuously monitor insulation integrity and earth leakage currents in AC electrical installations. Rated for residual currents up to 2000 mA across a supply voltage range of 230–400 V AC, the RD2 provides reliable early-warning protection for industrial control panels and distribution systems, enabling preventive maintenance before a fault escalates to a trip event.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSM142120R1201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230…400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.105 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542058007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Verified RoHS compliance declaration for the European market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered and compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 62020:\u003c\/strong\u003e Designed and tested to IEC EN 62020 — the international standard for residual current monitors (RCMs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 62020:\u003c\/strong\u003e Meets the European harmonised standard for electrical accessories and residual current monitors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB RD2 residual current monitoring relay is widely deployed in industrial automation, commercial building management, and infrastructure applications where continuous leakage current surveillance is critical. Typical applications include monitoring of motor feeder circuits, IT and TN earthing systems, uninterruptible power supplies (UPS), data centre power distribution, HVAC control panels, and process manufacturing lines where unplanned shutdowns must be avoided. By providing an early warning output before the leakage current reaches the disconnection threshold, the RD2 enables maintenance teams to schedule corrective action without interrupting production.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025571099,"sku":"2CSM142120R1201","price":163.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csm142120r1201-rd2-abb-2csm142120r1201-rd2_f8e1c2c1-053a-4977-aadd-92bf214cc9df.webp?v=1777393366"},{"product_id":"abb-2csj201001r0002-rd3-500ma-residual-current-monitor","title":"ABB 2CSJ201001R0002 RD3 Type A 500mA 230-400V AC 3.6W Residual Current Monitor","description":"\u003cp\u003eThe ABB RD3 (2CSJ201001R0002) is a Type A Residual Current Monitor designed to continuously supervise earth leakage currents in AC electrical installations. The RD3 operates across a rated voltage range of 230–400 V AC, responds at an adjustable threshold of 500 mA, and consumes only 3.6 W — making it a compact, energy-efficient solution for panel builders and maintenance engineers who need reliable insulation fault detection. Certified to IEC EN 60947-2 and carrying CE and RoHS marks, the ABB RD3 is ready for deployment in industrial control panels and building automation systems worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ201001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Value (Residual Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230...400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542734833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable EU harmonisation legislation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS2 directive compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU Commission Delegated Directive (RoHS3) compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit-breakers standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant disposal marking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eContinuous earth leakage monitoring in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eInsulation fault detection in manufacturing and process automation environments\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems requiring residual current supervision\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance monitoring to reduce unplanned downtime\u003c\/li\u003e\n\u003cli\u003eProtection of sensitive equipment where nuisance tripping from conventional RCDs must be avoided\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025702171,"sku":"2CSJ201001R0002","price":223.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj201001r0002-rd3-abb-2csj201001r0002-rd3_8cf7624d-ca67-48c8-9342-d2e45e047b7b.webp?v=1777393374"},{"product_id":"abb-2csj202001r0002-rd3m-residual-current-monitoring-relay","title":"ABB 2CSJ202001R0002 RD3M 1-500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD3M (2CSJ202001R0002) is a DIN-rail mounted residual current monitoring relay designed to continuously supervise insulation integrity and detect earth leakage currents in AC electrical installations. Part of the ABB RD3 series, the RD3M provides adjustable sensitivity from 1 to 500 mA at rated voltages of 230 to 400 V AC, making it suitable for early fault detection in control panels, machinery, and distribution systems. Rated at just 3.6 W power consumption, this compact unit measures 52.8 × 85 × 65 mm and weighs only 223 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ202001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA (adjustable 1–500 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 … 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542747031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS recast directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliance with updated RoHS substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2 Annex M:\u003c\/strong\u003e Residual current device requirements per IEC\/EN 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European harmonised standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB RD3M residual current monitoring relay is ideal for continuous earth leakage monitoring in industrial control panels, building electrical installations, and machine tool enclosures. Its wide adjustable current range (1–500 mA) enables both sensitive insulation monitoring for critical equipment and higher-threshold monitoring for general distribution boards. The DIN-rail form factor integrates seamlessly into standard control cabinets, supporting proactive maintenance strategies by providing early warning of insulation degradation before nuisance tripping or equipment damage occurs.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025767707,"sku":"2CSJ202001R0002","price":354.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj202001r0002-rd3m-abb-2csj202001r0002-rd3m_f5bbe89b-20fd-4764-9a70-4bbe81e0d71d.webp?v=1777393382"},{"product_id":"abb-2csj203001r0002-rd3p-residual-current-monitoring-relay","title":"ABB 2CSJ203001R0002 RD3P 500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD3P (SKU: 2CSJ203001R0002) is a Type A residual current monitoring relay designed to continuously supervise insulation integrity and detect earth fault currents in AC electrical installations. Part of the ABB RD3 series, the RD3P monitors leakage currents up to 500 mA across a rated voltage range of 230–400 V AC and mounts directly on standard DIN rail, making it an ideal solution for industrial control panels, distribution boards, and automation systems where earth fault detection is critical for personnel safety and equipment protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ203001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230–400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542733836\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Compliance with the European Union RoHS Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the RoHS amendment expanding restricted substances list\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2 Ann M:\u003c\/strong\u003e Meets Annex M requirements for residual current protection devices under IEC EN 60947-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Certified to the international standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e Compliant with the European harmonised standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth fault and leakage current monitoring in industrial control panels\u003c\/li\u003e\n\u003cli\u003eInsulation supervision in distribution boards and motor control centres\u003c\/li\u003ecatch\u003cli\u003ePersonnel protection in automation and process control systems\u003c\/li\u003e\n\u003cli\u003eContinuous residual current monitoring in commercial and industrial buildings\u003c\/li\u003e\n\u003cli\u003eIntegration with PLCs and SCADA systems via relay output signalling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025833243,"sku":"2CSJ203001R0002","price":361.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj203001r0002-rd3p-abb-2csj203001r0002-rd3p_36619c87-3f36-4cda-be6f-7c57b1b468d8.webp?v=1777393386"},{"product_id":"abb-2csg060100r1211-tr2-current-transformer","title":"ABB 2CSG060100R1211 TR2 100x110x50mm 0.230kg Current Transformer","description":"\u003cp\u003eThe ABB TR2 (2CSG060100R1211) is a toroidal current transformer designed for accurate current measurement in industrial control panels and energy monitoring applications. Part of ABB's trusted TR series, the TR2 features compact dimensions of 100 mm (W) × 110 mm (H) × 50 mm (D) and a lightweight 0.230 kg construction, making it suitable for space-constrained installations. The TR2 meets international compliance standards including CE, RoHS, WEEE, and REACH.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSG060100R1211\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.230 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542020400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, restricting use of harmful materials in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on the registration, evaluation, and authorisation of chemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCurrent measurement in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003eEnergy monitoring and metering systems\u003c\/li\u003e\n  \u003cli\u003ePower quality analysis and measurement\u003c\/li\u003e\n  \u003cli\u003eIntegration with energy analyzers and power meters\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and industrial automation installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025898779,"sku":"2CSG060100R1211","price":73.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csg060100r1211-tr2-abb-2csg060100r1211-tr2_41764cad-7c29-4bc5-a933-5757bd04da90.webp?v=1777393390"},{"product_id":"abb-2csm222471r1000-ad1no-15m-analog-time-switch","title":"ABB 2CSM222471R1000 AD1NO-15m 16A 230V AC DIN Rail Analogous Time Switch for Distribution Board","description":"\u003cp\u003eThe ABB AD1NO-15m (SKU: 2CSM222471R1000) is an analogous time switch designed for distribution board installation, delivering reliable daily cycle time control at 16A and 230V AC via compact DIN rail mounting. Part of the ABB AD1 series, the AD1NO-15m offers a straightforward mechanical switching mechanism ideal for lighting, HVAC, and general load scheduling in residential and commercial control panels. Weighing just 72g with a slim 17.5mm profile, this timer integrates seamlessly into space-constrained distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAD1NO-15m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSM222471R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogous Time Switch for Distribution Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 66 mm × 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542224716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU — restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Verified RoHS compliance under current EU legislation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60730-2-7:\u003c\/strong\u003e Automatic electrical controls for household and similar use — particular requirements for timers and time switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60730-2:\u003c\/strong\u003e Automatic electrical controls — general safety and performance standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025997083,"sku":"2CSM222471R1000","price":31.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csm222471r1000-ad1no-15m-abb-2csm222471r1000-ad1no-15m_f6e1b175-82bb-490a-ad02-c6b029585b67.webp?v=1777393396"},{"product_id":"abb-1svr560730r3401-cm-ufd-m31-voltage-monitoring-relay","title":"ABB 1SVR560730R3401 CM-UFD.M31 3C\/O Grid Feeding Voltage Monitoring Relay L-L 0-540V AC L-N 0-312V AC","description":"\u003cp\u003eThe ABB CM-UFD.M31 (SKU: 1SVR560730R3401) is a grid feeding voltage monitoring relay from the CM-UFD series, designed to monitor AC supply voltage in grid-connected photovoltaic and distributed energy systems. Offering a 3-changeover-contact output, a line-to-line measurement range of 0–540V AC and line-to-neutral range of 0–312V AC, the CM-UFD.M31 ensures compliant disconnection of grid-feeding inverters in accordance with German VDE-AR-N grid codes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-UFD.M31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR560730R3401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-UFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 C\/O (3 changeover contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range (L-L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–540V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range (L-N)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–312V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614492914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 mm × 90 mm × 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.304 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4105:\u003c\/strong\u003e German grid connection standard for low-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4110:\u003c\/strong\u003e German grid connection standard for medium-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4120:\u003c\/strong\u003e German grid connection standard for high-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrical safety and quality certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for use in North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU Regulation (EC) No 1907\/2006 — substances of very high concern compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive 2011\/65\/EU — compliant, hazardous substance restrictions met\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — product meets all applicable EU directives\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGrid-feeding photovoltaic (PV) inverter disconnection monitoring\u003c\/li\u003e\n\u003cli\u003eDistributed energy resource (DER) grid interface protection\u003c\/li\u003e\n\u003cli\u003eLow-, medium-, and high-voltage grid compliance monitoring per VDE-AR-N 4105 \/ 4110 \/ 4120\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial control panels requiring certified voltage supervision\u003c\/li\u003e\n\u003cli\u003eRenewable energy installations requiring automatic grid disconnection on voltage anomaly\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat is the CM-UFD.M31 used for?\u003c\/strong\u003e\u003cbr\u003eThe CM-UFD.M31 is a grid feeding monitoring relay used to supervise AC supply voltage in grid-connected systems. It detects voltage anomalies and triggers its 3 changeover contacts to disconnect grid-feeding inverters in compliance with VDE-AR-N grid codes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat voltage ranges does the CM-UFD.M31 support?\u003c\/strong\u003e\u003cbr\u003eIt monitors line-to-line (L-L) voltages from 0 to 540V AC and line-to-neutral (L-N) voltages from 0 to 312V AC, making it suitable for standard European three-phase systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich grid codes is the CM-UFD.M31 certified to?\u003c\/strong\u003e\u003cbr\u003eThe relay is certified to VDE-AR-N 4105 (low voltage), VDE-AR-N 4110 (medium voltage), and VDE-AR-N 4120 (high voltage), as well as holding CE, VDE, CSA, REACH, and RoHS certifications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229035794715,"sku":"1SVR560730R3401","price":1210.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr560730r3401-cm-ufd-m31-l-n-0-312v-ac_8634ed3e-8a7f-4fd6-a081-a1753946b704.webp?v=1777160764"},{"product_id":"abb-1sae901901r1011-eh04-11n-auxiliary-contact-block","title":"ABB 1SAE901901R1011 EH04-11N 2P 6A 500V AC Auxiliary Contact Block","description":"\u003cp\u003eThe ABB EH04-11N (SKU: 1SAE901901R1011) is a 2-pole auxiliary contact block rated at 6 A and 500 V AC, designed for use in auxiliary circuits operating at 50 Hz. The EH04-11N delivers reliable signal switching in compact control panel and automation installations, featuring a slim 9 mm wide profile that minimises space requirements on DIN rail assemblies. Weighing just 0.04 kg, this auxiliary contact block integrates seamlessly into industrial control systems requiring dependable auxiliary switching.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEH04-11N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAE901901R1011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEH04\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614527616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e IEC standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC\/EN designation for control circuit switchgear compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for robustness and reliability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAuxiliary switching in motor starters and contactors within control panels\u003c\/li\u003e\n  \u003cli\u003eSignal feedback and interlocking in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eStatus indication circuits in machine tool and process control applications\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail control assemblies requiring low-profile auxiliary contacts\u003c\/li\u003e\n  \u003cli\u003ePLC input signal interfaces in manufacturing and process industries\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117190427,"sku":"1SAE901901R1011","price":13.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sae901901r1011-eh04-11n-500v-ac-50hz_b7dd272d-4941-48f2-97e8-3ab32ced5369.webp?v=1777155810"},{"product_id":"abb-gjh1211001r8400-k6-40e-80-contactor-relay","title":"ABB GJH1211001R8400 K6-40E-80 4NO 3A 220-240VAC Mini Contactor Relay Screw Terminals","description":"\u003cp\u003eThe ABB K6-40E-80 (SKU: GJH1211001R8400) is a mini contactor relay from the K6 series, rated at 3 A with a 220–240 V AC coil and 4NO contact configuration. Designed for compact control panel integration, the K6-40E-80 supports both DIN rail and wall mounting and features screw terminals for reliable, tool-assisted wiring. At just 175 g and measuring 52.5 × 46.5 × 57.5 mm, it delivers industrial-grade switching performance in a space-saving footprint suited for automation, HVAC, and machinery control applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK6-40E-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJH1211001R8400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614153273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini Contactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4NO 0NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 × 46.5 × 57.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with updated EU RoHS II Directive (2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European adoption of IEC 60947-4 for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements (international standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European adoption of IEC 60947-5 for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117813019,"sku":"GJH1211001R8400","price":12.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjh1211001r8400-k6-40e-80-relay-screw-terminals_6122ed33-8d24-4fa5-9b37-f164b2e347ab.webp?v=1777162992"},{"product_id":"abb-gjh1213001r0221-kc6-22z-01-contactor-relay","title":"ABB GJH1213001R0221 KC6-22Z-01 Mini Contactor Relay 4P 3A 24V DC 2NO+2NC Screw Terminals","description":"\u003cp\u003eThe ABB KC6-22Z-01 (SKU: GJH1213001R0221) is a mini contactor relay designed for compact control panel installations, delivering reliable 24 V DC coil operation across a 4-pole configuration with 2NO+2NC contact arrangement. Rated at 3 A and 400 V, the KC6-22Z-01 is ideal for industrial automation and machine control applications where space efficiency and dependable switching performance are essential. Screw terminals ensure straightforward, secure wiring in demanding environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKC6-22Z-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJH1213001R0221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKC6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini Contactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NO + 2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 x 46.5 x 57.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614049644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Conformity requirements for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with the updated RoHS II Directive (2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — general rules for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC and EN general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements — IEC standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing procedures for electronic components and equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial automation and machine control panels requiring compact relay switching\u003c\/li\u003e\n\u003cli\u003eBuilding management and HVAC control systems with 24 V DC logic circuits\u003c\/li\u003e\n\u003cli\u003eProcess control and instrumentation panels with limited din rail space\u003c\/li\u003e\n\u003cli\u003eMotor auxiliary control and signalling circuits up to 400 V\u003c\/li\u003e\n\u003cli\u003eOEM machinery and production equipment requiring IEC\/EN certified relay components\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229118304539,"sku":"GJH1213001R0221","price":14.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjh1213001r0221-kc6-22z-01-2no-2nc-screw-terminals_d4886941-9367-4e64-bca7-40af38777f82.webp?v=1777162997"},{"product_id":"abb-gjl1201330r0004-caf6-11n-auxiliary-contact-block","title":"ABB GJL1201330R0004 CAF6-11N 1NO\/1NC 2P Front Mount Auxiliary Contact Block Screw Terminal","description":"\u003cp\u003eThe ABB CAF6-11N (SKU: GJL1201330R0004) is a front-mounted auxiliary contact block featuring a 1NO\/1NC contact configuration with screw terminals, designed for reliable status signalling and control circuit integration in industrial applications. Part of the CAF6 series, this 2-pole block mounts directly to compatible ABB contactors and motor starters, providing compact, certified contact expansion in control panels and automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAF6-11N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1201330R0004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAF6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614142666\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO \/ 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.5 × 26.5 × 29 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard — general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Underwriters Laboratories listed for Canada and USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Underwriters Laboratories certified for Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStatus signalling and feedback circuits in motor control panels\u003c\/li\u003e\n\u003cli\u003eInterlocking and sequencing control in industrial automation systems\u003c\/li\u003e\u0026lt; li\u0026gt;Auxiliary switching in contactor and motor starter assemblies\u003cli\u003eControl circuit expansion in manufacturing and process automation\u003c\/li\u003e\n\u003cli\u003eMachine tool and conveyor control panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229119189275,"sku":"GJL1201330R0004","price":4.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1201330r0004-caf6-11n-block-screw-terminal_8308d069-c85f-4df9-bdc0-91eb38325689.webp?v=1777163027"},{"product_id":"abb-1sbh101001r2653-ns53e-26-contactor-relay","title":"ABB 1SBH101001R2653 NS53E-26 230V 50\/60Hz 8-Pole Contactor Relay","description":"\u003cp\u003eThe ABB NS53E-26 contactor relay (SKU: 1SBH101001R2653) is an 8-pole control relay designed for industrial automation and control panel applications, featuring a 230V 50\/60Hz coil voltage and a compact 45 × 100.2 × 68 mm footprint. Part of ABB's NS series, the NS53E-26 delivers reliable switching performance in demanding environments and meets a comprehensive range of international standards including IEC, UL, CSA, CE, and UKCA.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS53E-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH101001R2653\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS53E\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 × 100.2 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523006263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e European harmonised standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for low-voltage control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions for low-voltage switchgear and controlgear assemblies — DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment (UL listed)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 N°14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e Canadian Standards Association electrical safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Restriction of Hazardous Substances Directive (recast) compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial control panels and machine automation circuits\u003c\/li\u003e\n  \u003cli\u003eInterlocking and signalling in motor control centres\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC control systems\u003c\/li\u003e\n  \u003cli\u003eProcess control and PLC output interface switching\u003c\/li\u003e\n  \u003cli\u003eMulti-circuit switching where 8 poles are required in a single device\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229119549723,"sku":"1SBH101001R2653","price":17.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh101001r2653-ns53e-26-8-pole-contactor-relay_9836a6fc-fe48-42fe-89f8-edfd10648526.webp?v=1777156618"},{"product_id":"abb-1sbh101001r2640-ns40e-26-contactor-relay","title":"ABB 1SBH101001R2640 NS40E-26 4-Pole 230V AC 50\/60Hz Contactor Relay","description":"\u003cp\u003eThe ABB NS40E-26 contactor relay (SKU: 1SBH101001R2640) is a 4-pole control relay from the ABB NS series, designed for 230V AC 50\/60Hz coil operation and engineered for use in control panels, industrial automation, and machine control circuits. Compact at 45 × 72.5 × 68 mm and weighing just 0.22 kg, the NS40E-26 delivers reliable switching performance where space and certified quality are critical.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS40E-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH101001R2640\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 × 72.5 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523002265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e International standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e European harmonised standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e General requirements for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensional requirements for DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment (North America)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 N°14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e Canadian Standards Association electrical safety standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union product safety directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with the updated EU RoHS II Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229119844635,"sku":"1SBH101001R2640","price":13.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh101001r2640-ns40e-26-abb-1sbh101001r2640-ns40e-26_c48139c4-17d5-40aa-8f9a-0f516337f210.webp?v=1777393828"},{"product_id":"abb-1sbh101001r2631-ns31e-26-contactor-relay","title":"ABB 1SBH101001R2631 NS31E-26 230V 50\/60Hz 4-Pole Contactor Relay","description":"\u003cp\u003eThe ABB NS31E-26 contactor relay (SKU: 1SBH101001R2631) is a 4-pole NS series control relay designed for industrial automation and control panel applications, operating on a 230V 50\/60Hz coil supply. Compact at just 45 mm wide and 72.5 mm deep, the NS31E-26 delivers reliable switching performance in space-constrained installations, weighing only 0.22 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS31E-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH101001R2631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS31E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523001268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5-1:\u003c\/strong\u003e European harmonised standard equivalent to IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — mechanical shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL recognized component for the North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 N°14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA certified for the Canadian market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with the updated EU RoHS II Directive (2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229119910171,"sku":"1SBH101001R2631","price":13.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh101001r2631-ns31e-26-4-pole-contactor-relay_c485188c-c260-4b9f-8c45-c7acfe16c6c5.webp?v=1777156605"},{"product_id":"abb-1sbh101001r2644-ns44e-26-contactor-relay","title":"ABB 1SBH101001R2644 NS44E-26 230V 50\/60Hz 8-Pole Contactor Relay","description":"\u003cp\u003eThe ABB NS44E-26 contactor relay (SKU: 1SBH101001R2644) is an 8-pole control relay designed for industrial automation and control panel applications, operating on a 230V 50\/60Hz coil voltage. Part of the ABB NS series, the NS44E-26 delivers reliable switching performance in a compact 45 × 100.2 × 68 mm form factor, weighing just 0.26 kg, making it well suited for space-constrained panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS44E-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH101001R2644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNS44E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 × 100.2 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523007260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1 \/ EN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e General standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear for DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment (UL Listed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 N°14:\u003c\/strong\u003e Canadian industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Hazardous substances restriction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial control panels requiring multi-pole relay switching\u003c\/li\u003e\n\u003cli\u003eMachine tool and automation system interlocking circuits\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control systems\u003c\/li\u003e\n\u003cli\u003eMotor control centres and auxiliary control circuits\u003c\/li\u003e\n\u003cli\u003eProcess control and manufacturing line automation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229120303387,"sku":"1SBH101001R2644","price":17.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh101001r2644-ns44e-26-8-pole-contactor-relay_5cb15414-7dde-44d2-997c-851fb58f0683.webp?v=1777156611"},{"product_id":"abb-1sbh137001r1322-nf22e-13-4p-690v-contactor-relay","title":"ABB 1SBH137001R1322 NF22E-13 4-Pole 690V AC\/DC 100-250V Coil Contactor Relay","description":"\u003cp\u003eThe ABB NF22E-13 contactor relay (SKU: 1SBH137001R1322) is a 4-pole industrial control relay rated at 690 V IEC \/ 600 V UL, designed for demanding control circuit and automation panel applications. Featuring a wide-range coil voltage of 100–250 V AC\/DC (50\/60 Hz), the NF22E-13 offers exceptional versatility across global installations. Compact in form at 87 × 79 × 47 mm and weighing just 0.27 kg, this ABB NF Series relay delivers reliable switching performance in space-constrained control panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF22E-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH137001R1322\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523100138\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V IEC \/ 600 V UL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 79 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed for North American safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — approved for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval register approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard — control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC\/EN standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL standard for safety of household appliances — particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e Canadian standard for household appliances — particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for the assessment of the ability to be repaired, reused, upgraded, and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-92:\u003c\/strong\u003e Sustainability requirements for electrical and electronic products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eControl circuit switching in industrial automation and motor control centres\u003c\/li\u003e\n  \u003cli\u003eMachine building and OEM panel wiring requiring a wide coil voltage range\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations (DNV, LR, RINA, RMRS approved)\u003c\/li\u003e\n  \u003cli\u003eHVAC and building management systems\u003c\/li\u003e\n  \u003cli\u003eProcess control panels in chemical, oil \u0026amp; gas, and water treatment plants\u003c\/li\u003e\n  \u003cli\u003eGlobal export projects requiring multi-certification compliance (CE, UKCA, UL, CSA, CCC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229140422939,"sku":"1SBH137001R1322","price":16.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh137001r1322-nf22e-13-coil-contactor-relay_be68917b-2f0b-4ebd-8683-a93adb737259.webp?v=1777156679"},{"product_id":"abb-1sbh137001r1331-nf31e-13-contactor-relay","title":"ABB 1SBH137001R1331 NF31E-13 3NO+1NC 4-Pole 100-250V AC\/DC Contactor Relay","description":"\u003cp\u003eThe ABB NF31E-13 contactor relay (SKU: 1SBH137001R1331) is a 4-pole auxiliary contactor relay from the ABB NF Series, rated at 690 V IEC \/ 600 V UL and designed for use in industrial control panels and automation systems. With a 3NO+1NC contact configuration and a wide coil voltage range of 100–250 V AC\/DC (50\/60 Hz), the NF31E-13 delivers reliable switching performance across diverse industrial environments. Its compact 87 × 79 × 47 mm footprint and lightweight 0.27 kg construction make it ideal for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF31E-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH137001R1331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF31E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC (50\/60 Hz) \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 79 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523100237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU electrical safety and EMC requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine equipment approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed (UL 508, UL 60335-2-40 LZGH2A2L) — North American safety standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements — electromechanical control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1 \/ IEC60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5 \/ IEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e Safety of household and similar electrical appliances — heating, cooling and dehumidifying appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment — North American standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e Canadian safety standard for heating\/cooling appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian standard — safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing — vibration test methods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse and recycle electrical and electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary standard for energy-related products sustainability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — compliant, free of restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — registered for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial control panels requiring auxiliary switching of control circuits\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control systems\u003c\/li\u003e\n\u003cli\u003eMachine tool and process automation interlocking\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (DNV, LR, RINA, RMRS approved)\u003c\/li\u003e\n\u003cli\u003eMotor control circuits requiring signal and status feedback contacts\u003c\/li\u003e\n\u003cli\u003eApplications requiring wide-range coil voltage compatibility (100–250 V AC\/DC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229140816155,"sku":"1SBH137001R1331","price":16.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh137001r1331-nf31e-13-ac-dc-contactor-relay_6abef8a4-f9ed-4037-9b7b-c9c6b186c5fc.webp?v=1777156684"},{"product_id":"abb-1sbh137001r1122-nf22e-11-contactor-relay","title":"ABB 1SBH137001R1122 NF22E-11 4-Pole 24-60V AC\/DC 2NO+2NC Contactor Relay","description":"\u003cp\u003eThe ABB NF22E-11 contactor relay (SKU: 1SBH137001R1122) is a 4-pole auxiliary relay from the ABB NF series, designed for control circuit switching in industrial automation and control panel applications. Rated at 690 V IEC \/ 600 V UL, the NF22E-11 features a 24–60 V AC (50\/60 Hz) and 20–60 V DC coil voltage range, making it highly versatile for mixed AC\/DC control systems. Compact at 87 × 79 × 47 mm and weighing just 0.27 kg, it is ideal for space-constrained installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF22E-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH137001R1122\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NO + 2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 79 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523100114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary product quality certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore industry approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — mandatory Korean safety mark\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval classification society approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping — marine certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — North American safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — Canadian safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear, general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC\/EN standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-1:\u003c\/strong\u003e Low-voltage switchgear general rules (IEC designation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock test method\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment — North American standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Safety of household appliances — particular requirements for heat pumps (A2L refrigerants)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for heat pump and A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian household and commercial electrical appliance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse, upgrade and recycle products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-92:\u003c\/strong\u003e Extended sustainability assessment standard for electrical products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — restriction of hazardous substances in products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliance with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eControl panel interlocking and signalling circuits in industrial machinery\u003c\/li\u003e\n  \u003cli\u003eAuxiliary switching in motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration systems requiring A2L refrigerant-rated components\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore automation panels (DNV, LR, RINA, RMRS approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and process control systems\u003c\/li\u003e\n  \u003cli\u003ePLC output expansion and relay interface modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229141307675,"sku":"1SBH137001R1122","price":20.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh137001r1122-nf22e-11-2no-2nc-contactor-relay_942a1bfe-0451-42cc-9808-c2979ea8a91f.webp?v=1777156642"},{"product_id":"abb-1sbh137001r1180-nf80e-11-contactor-relay","title":"ABB 1SBH137001R1180 NF80E-11 8-Pole 24-60V AC\/DC Contactor Relay","description":"\u003cp\u003eThe ABB NF80E-11 contactor relay (SKU: 1SBH137001R1180) is an 8-pole auxiliary contactor relay designed for industrial control circuit applications, featuring a wide coil voltage range of 24–60V AC (50\/60Hz) and 20–60V DC. Part of ABB's NF Series, this compact relay measures 87 × 113 × 47 mm and weighs just 0.32 kg, making it well-suited for space-constrained control panels in automation and industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF80E-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH137001R1180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 113 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523100312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for safety (UL 508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine equipment certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval classification society approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL standard for safety of household appliances — particular requirements for heat pumps and air conditioners (A2L refrigerants)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for heat pump and AC equipment with A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked standby functions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary requirements related to energy efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian household and similar electrical appliances safety standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eControl circuit switching in industrial automation panels\u003c\/li\u003e\n\u003cli\u003eMachine tool and process control systems\u003c\/li\u003e\n\u003cli\u003eHVAC and building management systems\u003c\/li\u003e\n\u003cli\u003eMarine and offshore control applications (DNV, LR, RINA, RMRS approved)\u003c\/li\u003e\n\u003cli\u003eMotor control centers and starter panels\u003c\/li\u003e\n\u003cli\u003eMulti-circuit signalling and interlocking systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229142159643,"sku":"1SBH137001R1180","price":34.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh137001r1180-nf80e-11-ac-dc-contactor-relay_ab875de8-36d4-464b-a857-5b738f1f55c0.webp?v=1777156674"},{"product_id":"abb-1sbh136001r2144-nfz44e-21-contactor-relay","title":"ABB 1SBH136001R2144 NFZ44E-21 8-Pole 24-60V AC\/DC Contactor Relay","description":"\u003cp\u003eThe ABB NFZ44E-21 contactor relay (SKU: 1SBH136001R2144) is an 8-pole control relay from ABB's NFZ series, designed for switching auxiliary circuits in industrial automation and control panel applications. Rated for coil voltages of 24–60V AC (50\/60Hz) and 20–60V DC, the NFZ44E-21 delivers versatile, reliable performance across a broad input voltage range. Compact and robust, it complies with major international standards including IEC 60947-5-1, UL 508, and CE, making it suitable for global deployments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFZ44E-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH136001R2144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523102316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 113 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for the UK market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine equipment approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval registry approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Standard for low-voltage control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European adoption of IEC 60947-1 general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European adoption of IEC 60947-5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Harmonised IEC\/EN general switchgear standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Harmonised IEC\/EN control circuit devices standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEMI F47-0706:\u003c\/strong\u003e Semiconductor equipment voltage sag immunity standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Safety of household appliances — heat pumps and air conditioners with A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for A2L refrigerant HVAC equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian household and commercial appliances standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association general certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired and upgraded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant with substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricts use of specific hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — proper disposal and recycling compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229142389019,"sku":"1SBH136001R2144","price":44.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh136001r2144-nfz44e-21-ac-dc-contactor-relay_aad9e7d4-0acb-4fcf-a461-3da0726d570b.webp?v=1777156632"},{"product_id":"abb-1sbh137001r1171-nf71e-11-contactor-relay","title":"ABB 1SBH137001R1171 NF71E-11 8-Pole 24-60V AC\/DC NF Series Contactor Relay","description":"\u003cp\u003eThe ABB NF71E-11 contactor relay (SKU: 1SBH137001R1171) is an 8-pole auxiliary\/contactor relay from ABB's NF Series, rated for coil voltages of 24–60V AC (50\/60 Hz) and 20–60V DC, with a maximum rated voltage of 690V AC (IEC) \/ 600V UL. Designed for demanding industrial automation and control panel applications, the NF71E-11 delivers reliable switching performance in compact dimensions of 87 × 113 × 47 mm and a lightweight 0.32 kg profile, making it ideal for space-constrained installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF71E-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH137001R1171\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523100411\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60V AC (50\/60 Hz) \/ 20–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 113 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1 \/ IEC60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5 \/ IEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL \/ UL 508:\u003c\/strong\u003e UL Listed for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL standard for heat pumps, air conditioners using A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e CSA standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA standard for air conditioning\/heat pump equipment with A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335 \/ CSA C22.2 No.14 \/ CSA:\u003c\/strong\u003e Canadian Standards Association certification for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore equipment approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — marine classification approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping — marine certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — mechanical shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked standby functionality\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Energy efficiency supplement standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eControl panel auxiliary switching in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eSignal and control circuit switching in machine control cabinets\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration equipment control (A2L refrigerant systems)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore automation panels (DNV, LR, RINA, RMRS approved)\u003c\/li\u003e\n  \u003cli\u003eMulti-pole auxiliary relay applications requiring 8 contacts in a single device\u003c\/li\u003e\n  \u003cli\u003eOEM machinery and process automation where wide coil voltage range (24–60V AC\/DC) is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229142454555,"sku":"1SBH137001R1171","price":34.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh137001r1171-nf71e-11-series-contactor-relay_8df68dcb-4ec0-45f7-9b4c-1edaa3a114e1.webp?v=1777156670"},{"product_id":"abb-1sbh136001r2171-nfz71e-21-contactor-relay","title":"ABB 1SBH136001R2171 NFZ71E-21 8-Pole 24-60V AC\/DC Contactor Relay","description":"\u003cp\u003eThe ABB NFZ71E-21 contactor relay (SKU: 1SBH136001R2171) is an 8-pole industrial control relay from the NFZ series, designed for demanding automation and control panel applications. Rated for a coil voltage of 24–60V AC (50\/60 Hz) and 20–60V DC, the NFZ71E-21 delivers reliable switching performance in compact dimensions of 87 × 113 × 47 mm and a weight of just 0.36 kg, making it suitable for space-constrained control cabinet installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFZ71E-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBH136001R2171\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523102019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 × 113 × 47 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — UL 508 and UL 60335-2-40 LZGH2 A2L listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — certified for Chinese market requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval register certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping — marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e International standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1 \/ IEC60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5 \/ IEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEMI F47-0706:\u003c\/strong\u003e Semiconductor equipment voltage sag immunity standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Standard for safety of household and similar electrical appliances (A2L refrigerants)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14-13:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335 \/ CSA C22.2 No.14 \/ CSA:\u003c\/strong\u003e Canadian Standards Association certifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard — climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be repaired and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU RoHS Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229143011611,"sku":"1SBH136001R2171","price":44.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbh136001r2171-nfz71e-21-ac-dc-contactor-relay_bbba7a53-a5be-4e0d-ae7e-9e441b98b269.webp?v=1777156637"},{"product_id":"abb-1sbn010140r1240-ca4-40n-auxiliary-contact-block","title":"ABB 1SBN010140R1240 CA4-40N 4P Auxiliary Contact Block","description":"\u003cp\u003eThe ABB CA4-40N auxiliary contact block (SKU: 1SBN010140R1240) is a 4-pole add-on contact module designed for industrial control and automation applications. Part of the ABB CA4 series, this compact auxiliary contact block measures just 43 mm × 43 mm × 39.5 mm and weighs only 55 g, making it ideal for space-constrained control panels and motor starter assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCA4-40N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN010140R1240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCA4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43 mm × 43 mm × 39.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance — restricted substance compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e International standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC\/EN compliance for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-5-1:\u003c\/strong\u003e UL standard for low-voltage switchgear control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL standard for safety of household and similar appliances — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-5-1-14:\u003c\/strong\u003e Canadian Standards Association standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA standard for safety of appliances — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA standard for safety of household and similar appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for the Canadian market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — certified for the Chinese market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229143339291,"sku":"1SBN010140R1240","price":9.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn010140r1240-ca4-40n-auxiliary-contact-block_7b5e3858-504c-4bf8-ad29-1615ade9adb8.webp?v=1777157053"},{"product_id":"abb-1sbn020114r1000-tef4-off-timer-block","title":"ABB 1SBN020114R1000 TEF4-OFF Frontal Electronic Timer Block 2P Front-Mount 82x56x51mm","description":"\u003cp\u003eThe ABB TEF4-OFF (SKU: 1SBN020114R1000) is a front-mounted electronic timer block designed for seamless integration with compatible ABB contactors and motor starters in industrial automation and control panel applications. The TEF4-OFF provides reliable timing functionality in a compact 82 × 56 × 51 mm form factor, weighing only 0.065 kg, making it ideal for space-constrained installations. Engineered to meet a wide range of international standards, it is a trusted choice for engineers and procurement professionals worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEF4-OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN020114R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTimer Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 × 56 × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories recognized component\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL standard for particular requirements for electrical heat pumps, air-conditioners and dehumidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22-2 No.14-18:\u003c\/strong\u003e CSA standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA standard for heat pumps, air-conditioners and dehumidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA household and similar electrical appliances safety standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC and EN harmonised standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229146648859,"sku":"1SBN020114R1000","price":37.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn020114r1000-tef4-off-2p-front-mount-82x56x51mm_06614a7d-fbb3-4e9a-a629-f2009b565c94.webp?v=1777157081"},{"product_id":"abb-1sbn020112r1000-tef4-on-timer-block","title":"ABB 1SBN020112R1000 TEF4-ON Frontal Electronic Timer Block 2P Front-Mount 82x56x51mm","description":"\u003cp\u003eThe ABB TEF4-ON (1SBN020112R1000) is a front-mounted electronic timer block designed for precise time-delay control in industrial automation and control panel applications. This 2-pole timer block mounts directly to the front of compatible ABB devices, providing a compact and reliable timing solution. Weighing just 65 g and measuring 82 × 56 × 51 mm, the TEF4-ON integrates seamlessly into space-constrained control assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEF4-ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBN020112R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTEF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrontal Electronic Timer Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 × 56 × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523130630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL standard for household and similar electrical appliances, Part 2-40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Combined IEC and EN compliance for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22-2 No.14-18:\u003c\/strong\u003e Canadian Standards Association — industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA standard for household and similar appliances, Part 2-40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA household and similar electrical appliances standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229147205915,"sku":"1SBN020112R1000","price":37.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbn020112r1000-tef4-on-2p-front-mount-82x56x51mm_5212bff1-809f-4e52-8529-1a883a597fdd.jpg?v=1777157077"},{"product_id":"abb-1sax121001r1105-ef19-18-9-electronic-overload-relay","title":"ABB 1SAX121001R1105 EF19-18.9 Electronic Overload Relay 5.7-18.9A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF19-18.9\u003c\/strong\u003e electronic overload relay (SKU: 1SAX121001R1105) delivers precise motor protection across a wide current range of \u003cstrong\u003e5.7 to 18.9 A\u003c\/strong\u003e in a compact 3-pole configuration. Designed for industrial automation and control panel applications, the EF19-18.9 offers reliable trip performance compliant with IEC\/EN 60947 standards, making it the preferred choice for engineers and procurement professionals specifying robust motor protection in demanding environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19-18.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX121001R1105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.7 – 18.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91 × 68 × 51.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614404023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonized standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electronic components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e European standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked standby equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL certification for electrical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for EAEU markets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEF19-18.9\u003c\/strong\u003e electronic overload relay is designed for motor protection in industrial automation systems, control panels, and machinery. Its adjustable current range of 5.7–18.9 A makes it suitable for protecting three-phase motors in HVAC systems, conveyors, pumps, compressors, and general-purpose industrial drives. The relay integrates seamlessly with ABB EF-series contactors and motor starters, enabling efficient panel assembly and system coordination. With ATEX and IECEx certifications, it is also approved for deployment in hazardous classified areas.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229154742555,"sku":"1SAX121001R1105","price":65.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax121001r1105-ef19-18-9-relay-5-7-18-9a-3p_e7df8746-2a9c-43e6-add8-db4cbc65f171.webp?v=1777156326"},{"product_id":"abb-1sax121001r1104-ef19-6-3-electronic-overload-relay","title":"ABB 1SAX121001R1104 EF19-6.3 Electronic Overload Relay 1.9-6.3A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF19-6.3\u003c\/strong\u003e electronic overload relay (SKU: 1SAX121001R1104) delivers precise motor protection across a current range of 1.9 to 6.3 A in a compact 3-pole design. Part of ABB's trusted EF19 series, this relay is engineered for demanding industrial automation and control panel applications, offering reliable overload and phase-failure protection with a wide portfolio of international certifications including ATEX, UL, and CE.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19-6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX121001R1104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.9 … 6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91 × 68 × 51.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614404016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear standards compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor-starters — electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical systems for electric-drive vehicles (zero-emission applicable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for Canadian market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the Eurasian Economic Union market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEF19-6.3\u003c\/strong\u003e electronic overload relay is ideally suited for motor protection in industrial automation systems, control panels, and machinery where reliable overcurrent detection is critical. Its 1.9–6.3 A adjustable range makes it suitable for protecting small to medium-sized motors in manufacturing, process control, HVAC, and pumping applications. The compact 91 × 68 × 51.5 mm footprint ensures easy integration into tight panel assemblies, while broad international certifications — including ATEX for hazardous areas and UL\/CSA for North American installations — make the ABB 1SAX121001R1104 a truly global solution for motor protection engineers and procurement professionals.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155037467,"sku":"1SAX121001R1104","price":65.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax121001r1104-ef19-6-3-relay-1-9-6-3a-3p_0e039a20-8278-4507-ae45-662bb7045e82.webp?v=1777156322"},{"product_id":"abb-1sax121001r1101-ef19-0-32-electronic-overload-relay","title":"ABB 1SAX121001R1101 EF19-0.32 0.10-0.32A 3P Electronic Overload Relay","description":"\u003cp\u003eThe ABB EF19-0.32 (SKU: 1SAX121001R1101) is a 3-pole electronic overload relay with a current setting range of 0.10 to 0.32 A, designed for precise motor protection in demanding industrial automation and control panel applications. Part of ABB's EF19 series, the EF19-0.32 offers a compact footprint of 91 × 68 × 51.5 mm and carries an extensive portfolio of international certifications including ATEX, IECEx, UL, CE, and DNV, making it suitable for use in hazardous and marine environments worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19-0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX121001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Setting Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10 … 0.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91 × 68 × 51.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614403989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International standard for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for Russia\/CIS markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories certification (UL 2799)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear standard suite\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessment of the ability to recover materials and energy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity declaration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155103003,"sku":"1SAX121001R1101","price":62.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax121001r1101-ef19-0-32-abb-1sax121001r1101-ef19-0-32_d02a1e25-ca6b-4a21-a816-41da17e9680f.webp?v=1777393854"},{"product_id":"abb-1sax121001r1103-ef19-2-7-electronic-overload-relay","title":"ABB 1SAX121001R1103 EF19-2.7 Electronic Overload Relay 0.80-2.7A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF19-2.7\u003c\/strong\u003e electronic overload relay (SKU: 1SAX121001R1103) delivers precise motor protection with a current setting range of 0.80 to 2.7 A across 3 poles. Designed for demanding industrial automation and control panel applications, the EF19-2.7 combines compact dimensions of 91 × 68 × 51.5 mm with a lightweight 0.183 kg profile, making it an efficient choice for engineers specifying reliable overload protection in space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19-2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX121001R1103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.80 … 2.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91 × 68 × 51.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614404009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for customs union markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register approval for marine and offshore use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale approval for marine installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed (UL 2799)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonized standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155234075,"sku":"1SAX121001R1103","price":60.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax121001r1103-ef19-2-7-relay-0-80-2-7a-3p_12ee9c2d-f746-43da-8433-23beaccd34f5.webp?v=1777156314"},{"product_id":"abb-1sax821001r1101-ef750-800-electronic-overload-relay","title":"ABB 1SAX821001R1101 EF750-800 Electronic Overload Relay 250-800A 3P 144x270x250mm","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF750-800\u003c\/strong\u003e electronic overload relay (SKU: 1SAX821001R1101) delivers advanced motor protection across a wide current range of 250 to 800A, making it an ideal solution for heavy-duty industrial automation and control panel applications. Part of the ABB EF750 series, this 3-pole electronic overload relay combines precise trip characteristics with robust construction — engineered for demanding environments where reliable motor protection is non-negotiable.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF750-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX821001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 … 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 x 270 x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.915 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614487422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (European Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Italian Naval Register type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed — North American safety standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for robustness and climatic endurance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance (ECHA SVHC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the Eurasian Economic Union\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB \u003cstrong\u003eEF750-800\u003c\/strong\u003e electronic overload relay is designed for protecting large industrial motors in applications including compressors, pumps, fans, conveyors, and heavy processing machinery. Its wide 250–800A adjustment range makes it highly versatile across variable load profiles in industrial automation, marine installations, oil and gas facilities, and utility substations. Procurement engineers specifying motor protection for MCC panels or standalone motor starters will find the EF750-800 compliant with international standards and suitable for global deployment.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155365147,"sku":"1SAX821001R1101","price":549.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax821001r1101-ef750-800-250-800a-3p-144x270x250mm_23c37d36-03cf-4d62-8664-5e2eb70c2f00.webp?v=1777156349"},{"product_id":"abb-1sax531001r1101-ef205-210-electronic-overload-relay","title":"ABB 1SAX531001R1101 EF205-210 63-210A 3P Electronic Overload Relay","description":"\u003cp\u003eThe ABB EF205-210 electronic overload relay (SKU: 1SAX531001R1101) provides precise motor protection across a wide 63–210 A adjustment range with a compact 3-pole design. As part of the EF205 series, this relay delivers advanced electronic overload detection suited to demanding industrial automation and control panel applications, and carries an extensive portfolio of global approvals including ATEX, UL, CE, and CCC certification.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF205-210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX531001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63–210 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195 × 140 × 199 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.624 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614442223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (European Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing for North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard — control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and components from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems using solid-state inverters and converters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the Customs Union (Russia, Belarus, Kazakhstan)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB EF205-210 electronic overload relay is engineered for motor protection in heavy-duty industrial environments. Its broad 63–210 A setting range makes it suitable for large motors in manufacturing automation, pump stations, compressor drive panels, HVAC plant rooms, and process control installations. The ATEX and IECEx approvals extend its use to oil \u0026amp; gas, chemical, and mining facilities where explosive atmospheres may be present. Marine approvals (RINA, RMRS) qualify the EF205-210 for shipboard motor control centres and offshore installations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155430683,"sku":"1SAX531001R1101","price":246.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax531001r1101-ef205-210-abb-1sax531001r1101-ef205-210_f17d1dc0-272a-48b8-af86-bbd8920c15f4.webp?v=1777393858"},{"product_id":"abb-1sax611001r1101-ef370-380-electronic-overload-relay","title":"ABB 1SAX611001R1101 EF370-380 Electronic Overload Relay 115...380A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF370-380 electronic overload relay\u003c\/strong\u003e (SKU: 1SAX611001R1101) delivers precise, reliable motor protection across a wide current range of 115 to 380 A in a compact 3-pole configuration. Designed for demanding industrial automation and control panel applications, the EF370-380 combines advanced electronic tripping technology with a robust mechanical design — making it an industry-standard choice for engineers specifying motor protection in heavy-duty installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF370-380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX611001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115...380 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195 x 140 x 199 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.706 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614442216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International standard for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories certification for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale certification for marine use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — comprehensive series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing procedures for electronic and electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements — European standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical systems of electric drive vehicles (UL listing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for Canadian and North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals (EU regulation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the Eurasian Economic Union\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB EF370-380 electronic overload relay is engineered for motor protection in high-current industrial environments. Typical applications include heavy-duty motor starters in manufacturing plants, process automation systems, pump and compressor control panels, marine and offshore electrical installations, and any control panel requiring reliable overload protection up to 380 A. Its broad certification portfolio — spanning ATEX, IECEx, UL, LR, RINA, CE, UKCA, and EAC — ensures global deployment flexibility across European, North American, Asian, and maritime markets.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229155496219,"sku":"1SAX611001R1101","price":284.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax611001r1101-ef370-380-relay-115-380a-3p_f0c0b747-44ec-455f-9249-d5f026163b76.webp?v=1777156345"},{"product_id":"abb-1sax721001r1101-ef460-500-electronic-overload-relay","title":"ABB 1SAX721001R1101 EF460-500 150-500A 3P Electronic Overload Relay","description":"\u003cp\u003eThe ABB EF460-500 (SKU: 1SAX721001R1101) is a 3-pole electronic overload relay rated for 150 to 500 A, designed for reliable motor protection in demanding industrial automation environments. Part of the ABB EF460 series, the EF460-500 delivers precise overload detection and tripping to safeguard motors and downstream equipment in control panels and distribution systems. Weighing 1.554 kg, it is built for robust, long-term service in heavy-duty applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF460-500\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX721001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF460\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ... 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.554 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614487415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment used in explosive atmospheres per IEC standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed, confirming compliance with North American safety standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Certified by the Italian Naval Register for marine and offshore applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection in industrial automation and control panel installations\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty motor drives in oil \u0026amp; gas, petrochemical, and mining environments (ATEX\/IECEx rated)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor protection systems (RINA certified)\u003c\/li\u003e\n  \u003cli\u003eLarge pump, compressor, and fan drive protection up to 500 A\u003c\/li\u003e\n  \u003cli\u003eNorth American installations requiring UL-listed overload protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229156348187,"sku":"1SAX721001R1101","price":460.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax721001r1101-ef460-500-abb-1sax721001r1101-ef460-500_dbc6e691-fb1f-4798-ad5d-3ae9f3cc7763.webp?v=1777393861"},{"product_id":"abb-1sax351001r1101-ef146-150-electronic-overload-relay","title":"ABB 1SAX351001R1101 EF146-150 Electronic Overload Relay 54-150A 3P 160x107x97mm","description":"\u003cp\u003eThe ABB EF146-150 electronic overload relay (SKU: 1SAX351001R1101) delivers precise motor protection across a wide current range of 54 to 150A in a compact 3-pole design. Part of the proven EF146 series, the EF146-150 is engineered for demanding industrial automation and control panel applications where reliable overload detection is critical. Weighing just 0.984 kg and measuring 160 x 107 x 97 mm, it integrates seamlessly into motor protection assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF146-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX351001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54...150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 107 x 97 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.984 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614442230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale certification for marine installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear (general rules)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European harmonised standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for Electrical Systems for Stationary Fuel Cell Power Systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance (EU 2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity marking for the Eurasian Economic Union\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe EF146-150 is the preferred electronic overload relay for high-current motor protection in industrial automation, manufacturing plants, pump stations, compressor systems, and HVAC equipment. Its broad adjustment range (54–150A) makes it suitable for a wide variety of motor sizes without requiring a relay change, reducing spare-parts inventory. The relay's electronic sensing technology provides class-leading trip accuracy, phase-loss sensitivity, and thermal memory — essential for protecting high-value motors in continuous-duty industrial environments. Its international certification portfolio (ATEX, IECEx, UL, CCC, EAC, UKCA, CE) makes the EF146-150 the go-to choice for global projects and export-controlled installations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229156643099,"sku":"1SAX351001R1101","price":185.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax351001r1101-ef146-150-54-150a-3p-160x107x97mm_80e39d2e-8914-497b-b813-f903b27d586e.webp?v=1777156340"},{"product_id":"abb-1sax341001r1101-ef96-100-electronic-overload-relay","title":"ABB 1SAX341001R1101 EF96-100 Electronic Overload Relay 36-100A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF96-100\u003c\/strong\u003e (SKU: 1SAX341001R1101) is an electronic overload relay engineered for reliable motor protection in demanding industrial automation environments. Covering a rated current range of 36 to 100 A across 3 poles, the EF96-100 delivers precise, adjustable overload detection to safeguard motors and control panel equipment. Compact in form at 139 × 107 × 75.5 mm and weighing just 0.857 kg, it is designed for straightforward integration into modern motor control and protection assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF96-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Internal Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX341001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 … 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e139 × 107 × 75.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.857 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614442247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed — North American safety standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Italian Naval Register certification for marine equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — general rules for LV switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive LV switchgear and controlgear series compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standards (climatic and mechanical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor-starters standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical energy storage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation (EC No 1907\/2006) compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — EU market declaration of conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — Great Britain market marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for EAEU member states\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eEF96-100\u003c\/strong\u003e electronic overload relay is ideally suited for motor protection in heavy industrial applications where accurate trip thresholds and robust certification coverage are essential. Typical deployment scenarios include large pump stations, compressor drives, conveyor systems, HVAC plant rooms, and offshore or marine motor control panels where ATEX or LR\/RINA ratings are mandatory. Its 36–100 A adjustment range makes it a versatile choice for motor starters built around ABB contactors in the EF96 series ecosystem, reducing the need for multiple relay variants across a site.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229157363995,"sku":"1SAX341001R1101","price":153.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax341001r1101-ef96-100-relay-36-100a-3p_9b1c88a4-f39a-4ab9-bca3-f0575a1c6f27.webp?v=1777156335"},{"product_id":"abb-1sax331001r1101-ef65-70-electronic-overload-relay","title":"ABB 1SAX331001R1101 EF65-70 Electronic Overload Relay 25-70A 3P","description":"\u003cp\u003eThe \u003cstrong\u003eABB EF65-70\u003c\/strong\u003e electronic overload relay (SKU: 1SAX331001R1101) delivers precise motor protection across a wide current range of 25 to 70A in a compact 3-pole configuration. Designed for demanding industrial automation and control panel applications, the EF65-70 combines advanced electronic sensing with a robust mechanical design, offering reliable and repeatable protection for motors in harsh environments. Part of the ABB EF65 series, it meets global certification standards including ATEX, UL, CE, and IECEx.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF65-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAX331001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEF65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25...70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e139 x 107 x 75.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.876 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614442254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for equipment used in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for markets in Russia and Eurasian Economic Union\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Italian naval classification society certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — General rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear — General rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive low-voltage switchgear and controlgear standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical and electronic items\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Contactors and motor starters standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for zero liquid discharge water treatment systems (supplemental UL listing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for Canadian market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant with SVHC requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking indicating compliance with EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB EF65-70 electronic overload relay is engineered for motor protection in industrial automation systems, manufacturing machinery, pumps, compressors, conveyors, and HVAC equipment. Its wide current adjustment range makes the EF65-70 a versatile solution for control panels requiring protection of motors from 25A up to 70A. The device is well-suited for installation in process industries, marine environments (LR, RINA, RMRS certified), and hazardous locations (ATEX\/IECEx), making it a globally accepted choice for procurement engineers and system integrators.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229158510875,"sku":"1SAX331001R1101","price":125.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sax331001r1101-ef65-70-relay-25-70a-3p_d672e415-277b-4a4a-8781-3d548189d175.webp?v=1777156331"}],"url":"https:\/\/stoklink.com\/collections\/relay.oembed?page=10","provider":"Stoklink","version":"1.0","type":"link"}