{"title":"RCD Add-on Blocks \u0026 Earth Leakage Relays","description":"\u003cp\u003eRCD add-on blocks and earth leakage relays from ABB and Schneider Electric add residual current protection to existing MCBs or monitor leakage on a panel. The range includes ABB DDA200 blocks in 2, 3 and 4 poles from 25 A to 63 A, ABB RD2 and RD3 monitoring relays and Schneider Electric Acti9 blocks. Stoklink ships worldwide from Turkey.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eABB DDA200 RCD blocks that mount on S200 series MCBs, in 2P, 3P and 4P.\u003c\/li\u003e\n\u003cli\u003eABB RD2 and RD3 residual current monitoring relays for use with a separate toroid.\u003c\/li\u003e\n\u003cli\u003eSchneider Electric Acti9 add-on blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCompatibility: the block must match the MCB series, pole count and rated current.\u003c\/li\u003e\n\u003cli\u003eFunction: a block trips the MCB. A relay only signals or trips through a separate device.\u003c\/li\u003e\n\u003cli\u003eType: AC or A for the load.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eCan an RCD block be fitted to any MCB?\u003c\/h3\u003e\u003cp\u003eNo. Use the block specified for the MCB series and pole count. Mixing brands or series is not covered by the manufacturer.\u003c\/p\u003e\u003ch3\u003eWhat does a residual current monitoring relay do?\u003c\/h3\u003e\u003cp\u003eIt measures leakage current through a toroid and gives an alarm or trip signal at an adjustable threshold. It does not interrupt the circuit by itself.\u003c\/p\u003e\u003ch3\u003eDo you ship these to export markets?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships from Turkey, EXW, and quotes project quantities on request.\u003c\/p\u003e","products":[{"product_id":"abb-2csb202001r1250-dda202-ac-25-0-03-2p-25a-rccb","title":"ABB 2CSB202001R1250 DDA202 AC-25\/0.03 2P 25A 30mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA202 AC-25\/0.03 (SKU: 2CSB202001R1250) is a 2-pole 25A residual current circuit breaker module from the DDA200 series, providing 30mA Type AC earth-fault protection for residential and light commercial installations. Designed to pair with ABB's DS200 series MCBs, the DDA202 AC-25\/0.03 delivers reliable personnel protection against indirect contact and enhanced safety in control panels and distribution boards. With compact dimensions of 70mm × 93mm × 69mm and a weight of just 175g, it fits easily into standard DIN rail assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA202 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB202001R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542791102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian certification mark confirming compliance with safety and performance standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French NF certification confirming conformity with national safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for RCCBs — equivalent adoption of IEC 61009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009:\u003c\/strong\u003e Combined IEC\/EN designation for RCCB product compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering temperature, humidity and mechanical robustness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European adoption of insulation coordination requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard applicable to electrical systems for electric vehicles and related equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from lead, mercury, cadmium and other restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e European chemical safety regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against indirect contact in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth-fault protection in light commercial and industrial control panels\u003c\/li\u003e  \u003cli\u003eAdd-on residual current protection paired with ABB DS200 series MCBs\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted 2-pole RCCB modules in final circuits up to 25A\u003c\/li\u003e\n\u003cli\u003e30mA sensitive tripping for bathroom, kitchen, and outdoor circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997816603,"sku":"2CSB202001R1250","price":56.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb202001r1250-dda202-ac-25-0-03-circuit-breaker-module_7e5d9f15-6f6a-4bb7-8036-9c64e68f0a2e.webp?v=1777162600"},{"product_id":"abb-2csb202001r1400-dda202-ac-40-0-03-2p-40a-rccb","title":"ABB 2CSB202001R1400 DDA202 AC-40\/0.03 2P 40A 30mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA202 AC-40\/0.03 (SKU: 2CSB202001R1400) is a 2-pole 40A residual current circuit breaker module from the DDA200 series, designed to provide 30mA earth-leakage protection in residential and commercial installations. This Type AC RCCB module detects sinusoidal alternating residual currents, offering reliable protection against electric shock and fire hazards caused by insulation faults. Compact at 70mm × 93mm × 69mm and weighing just 175g, the DDA202 AC-40\/0.03 integrates seamlessly into modular distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA202 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB202001R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542791201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian certification body approval for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French NF certification mark for product compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for RCCBs with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009:\u003c\/strong\u003e Combined IEC and EN standard for RCBO-type devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for mechanical and climatic durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical system packages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards requiring 30mA personal protection\u003c\/li\u003e\n\u003cli\u003eCommercial panel boards with earth-leakage protection requirements\u003c\/li\u003e\n\u003cli\u003eModular electrical installations in light industrial environments\u003c\/li\u003e\n\u003cli\u003eProtection of socket-outlet circuits against electric shock\u003c\/li\u003e\n\u003cli\u003eSupplementary protection in TN and TT earthing systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997882139,"sku":"2CSB202001R1400","price":56.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb202001r1400-dda202-ac-40-0-03-circuit-breaker-module_08a0f2fe-7e57-486a-b01f-5465397ee17a.webp?v=1777162605"},{"product_id":"abb-2csb202001r3250-dda202-ac-25-0-3-2p-25a-rccb","title":"ABB 2CSB202001R3250 DDA202 AC-25\/0.3 2P 25A 300mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA202 AC-25\/0.3 (SKU: 2CSB202001R3250) is a 2-pole residual current circuit breaker module rated at 25A with a 300mA sensitivity, belonging to the DDA200 series. Designed for Type AC applications, it provides reliable earth leakage protection in residential, commercial, and light industrial installations. With compact dimensions of 70mm × 93mm × 69mm and a weight of just 325g, the DDA202 AC-25\/0.3 integrates seamlessly into standard distribution boards and control panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA202 AC-25\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB202001R3250\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542791706\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian certification mark confirming compliance with safety and performance standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French NF certification mark for electrical equipment quality and safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current circuit breakers with integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61009 for RCCB devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment within electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical system safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards requiring earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations with 2-pole circuit configurations\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels requiring Type AC residual current protection\u003c\/li\u003e\n  \u003cli\u003eProtection of socket outlet circuits and fixed appliance circuits up to 25A\u003c\/li\u003e\n  \u003cli\u003eIntegration with ABB DDA200 series modular systems for scalable protection solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228998045979,"sku":"2CSB202001R3250","price":50.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb202001r3250-dda202-ac-25-0-3-circuit-breaker-module_458c4c29-91d2-43de-9946-07e46a48f49b.webp?v=1777162613"},{"product_id":"abb-2csb203001r1630-dda203-ac-63-0-03-3p-63a-rccb","title":"ABB 2CSB203001R1630 DDA203 AC-63\/0.03 3P 63A 30mA Type AC Residual Current Circuit Breaker RCCB Module","description":"\u003cp\u003eThe ABB DDA203 AC-63\/0.03 (SKU: 2CSB203001R1630) is a 3-pole residual current circuit breaker (RCCB) module from the DDA200 series, rated at 63 A with a 30 mA residual current trip threshold for Type AC earth fault protection. Designed for integration into modular protection assemblies, the DDA203 AC-63\/0.03 delivers reliable personal and installation protection against earth leakage currents in industrial and commercial control panel applications. Compact at 122.5 × 93 × 69 mm and weighing just 325 g, it is engineered for DIN rail mounting in space-critical enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA203 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB203001R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542792703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122.5 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian certification mark confirming compliance with national and international electrical safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French NF certification mark verifying compliance with applicable French and European standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61009 for RCCB\/RCBO devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems — dimensioning and testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering mechanical and climatic durability requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European harmonised insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems for electric-drive vehicles and associated safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003ePersonal protection against electric shock in commercial and light industrial installations\u003c\/li\u003e\n\u003cli\u003eModular protection assemblies requiring a dedicated 3-pole RCCB module at 63 A\u003c\/li\u003e\n\u003cli\u003eInstallations requiring Type AC sensitivity to sinusoidal alternating residual currents at 30 mA\u003c\/li\u003e\n\u003cli\u003eBuilding automation and facility management electrical distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228998668571,"sku":"2CSB203001R1630","price":61.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb203001r1630-dda203-ac-63-0-03-breaker-rccb-module_b72af8e1-b5f3-4a89-83e2-7a45bc826566.webp?v=1777162618"},{"product_id":"abb-2csb204001r1250-dda204-ac-25-0-03-4p-rccb","title":"ABB 2CSB204001R1250 DDA204 AC-25\/0.03 4P 25A 30mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA204 AC-25\/0.03 (SKU: 2CSB204001R1250) is a 4-pole residual current circuit breaker (RCCB) module from the DDA200 series, rated at 25 A with a 30 mA Type AC residual current sensitivity for reliable personal protection and fire prevention in industrial and commercial installations. Designed to detect earth fault currents of AC sinusoidal waveform, the DDA204 AC-25\/0.03 complements modular circuit protection systems and is suitable for integration into distribution boards and control panels requiring IEC 61009-compliant leakage protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB204001R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542793908\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian mark of quality for electrical safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French national certification mark for product conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for RCCBs with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009:\u003c\/strong\u003e Combined IEC and EN compliance for residual current devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electronic and electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-69:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical systems safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth leakage protection in residential, commercial, and light industrial distribution boards\u003c\/li\u003e\n\u003cli\u003ePersonnel protection against indirect contact in 4-wire (3-phase + neutral) AC systems\u003c\/li\u003e\n\u003cli\u003eFire prevention through detection of low-level earth fault currents (30 mA sensitivity)\u003c\/li\u003e\n\u003cli\u003eIntegration into modular protection schemes alongside MCBs in control panels\u003c\/li\u003e\n\u003cli\u003eBuilding automation and industrial automation control panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999127323,"sku":"2CSB204001R1250","price":70.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb204001r1250-dda204-ac-25-0-03-circuit-breaker-module_22834503-9fbb-4226-a7b4-512c2546207b.webp?v=1777162624"},{"product_id":"abb-2csb204001r1400-dda204-ac-40-0-03-4p-rccb","title":"ABB 2CSB204001R1400 DDA204 AC-40\/0.03 4P 40A 30mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA204 AC-40\/0.03 (SKU: 2CSB204001R1400) is a 4-pole residual current circuit breaker (RCCB) module from the DDA200 series, rated at 40A with a 30mA sensitivity for Type AC earth-fault protection. Designed for integration into control panels and distribution boards, this module detects sinusoidal alternating residual currents and disconnects the circuit to protect personnel and equipment. Compact at 105mm × 93mm × 69mm and weighing just 175g, the DDA204 AC-40\/0.03 is engineered to meet IEC 61009 and EN 61009 standards for demanding industrial and commercial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB204001R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542794004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian quality certification for electrical products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French national certification mark for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for RCCBs and RCBOs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009:\u003c\/strong\u003e Combined IEC and EN compliance for residual current devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for mechanical and climatic reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European insulation coordination standard for low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical vehicle supply equipment and energy storage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU Regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — registered for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential and commercial distribution boards requiring 4-pole earth-leakage protection\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels where personnel protection against indirect contact is mandatory\u003c\/li\u003e\n\u003cli\u003eThree-phase and neutral circuits demanding Type AC sinusoidal residual current detection\u003c\/li\u003e\n\u003cli\u003eAutomation and process control installations complying with IEC 61009 \/ EN 61009\u003c\/li\u003e\n\u003cli\u003ePanel builders integrating compact RCCB modules into DIN-rail assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999192859,"sku":"2CSB204001R1400","price":70.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb204001r1400-dda204-ac-40-0-03-circuit-breaker-module_a481bd36-c35f-4b31-b0df-bcd3ecfb6b31.webp?v=1777162629"},{"product_id":"abb-2csb204001r1630-dda204-ac-63-0-03-4p-63a-rccb","title":"ABB 2CSB204001R1630 DDA204 AC-63\/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA204 AC-63\/0.03 (SKU: 2CSB204001R1630) is a 4-pole residual current circuit breaker module from the DDA200 series, rated at 63 A with a 30 mA residual current sensitivity for Type AC earth-fault protection. Designed as an add-on RCD block, the DDA204 AC-63\/0.03 pairs with compatible MCBs to deliver reliable personnel and installation protection in commercial and industrial control panels. Weighing just 368 g, this compact RCCB module meets IEC 61009 and EN 61009 standards, making it suitable for demanding electrical installations worldwide.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB204001R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542794103\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker Module (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.368 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian quality mark — certified for use in Italian and EU electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French NF certification — conformity to French national electrical standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for RCCBs, aligned with IEC 61009\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009:\u003c\/strong\u003e Combined IEC and EN designation covering RCCB module performance and safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — verifies performance under temperature, humidity and mechanical stress\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical conversion systems — broadens market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU directive on hazardous materials in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — substances of very high concern (SVHC) compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — recyclable and responsibly disposable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial building distribution boards requiring earth-fault and personnel protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels where 4-pole RCD protection is mandated by local wiring regulations\u003c\/li\u003e\n  \u003cli\u003eTN-S and TT earthing systems demanding 30 mA high-sensitivity residual current detection\u003c\/li\u003e\n  \u003cli\u003eRetrofit upgrades: attaching the DDA204 AC-63\/0.03 block to existing DDA200-compatible MCBs\u003c\/li\u003e\n  \u003cli\u003eApplications requiring compliance with IEC 61009 \/ EN 61009 across European and international markets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999258395,"sku":"2CSB204001R1630","price":70.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb204001r1630-dda204-ac-63-0-03-circuit-breaker-module_5c22f76a-f83d-4c04-bbed-d7d7b245f250.webp?v=1777162634"},{"product_id":"abb-2csb204001r3400-dda204-ac-40-0-3-4p-40a-rccb","title":"ABB 2CSB204001R3400 DDA204 AC-40\/0.3 4P 40A 300mA Type AC Residual Current Circuit Breaker Module","description":"\u003cp\u003eThe ABB DDA204 AC-40\/0.3 (SKU: 2CSB204001R3400) is a 4-pole residual current circuit breaker module from the DDA200 series, rated at 40A with a 300mA Type AC sensitivity, designed for reliable earth-leakage protection in industrial and commercial installations. Measuring 105mm × 93mm × 69mm and weighing just 325g, the DDA204 AC-40\/0.3 integrates seamlessly into control panels and distribution boards where compact, dependable residual current protection is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA204 AC-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSB204001R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDDA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm × 93 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542794608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMQ:\u003c\/strong\u003e Italian certification body approval for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF:\u003c\/strong\u003e French national standard mark conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e International standard for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised standard for residual current circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for mechanical and climatic durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-69:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical energy storage systems safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to all applicable European Union directives\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999389467,"sku":"2CSB204001R3400","price":69.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csb204001r3400-dda204-ac-40-0-3-circuit-breaker-module_f3a5cdac-91bc-4198-8066-c109b56caa07.webp?v=1777162639"},{"product_id":"abb-2csm142120r1201-rd2-residual-current-monitoring-relay","title":"ABB 2CSM142120R1201 RD2 Type A 2000mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD2 (SKU: 2CSM142120R1201) is a Type A residual current monitoring relay designed to continuously monitor insulation integrity and earth leakage currents in AC electrical installations. Rated for residual currents up to 2000 mA across a supply voltage range of 230–400 V AC, the RD2 provides reliable early-warning protection for industrial control panels and distribution systems, enabling preventive maintenance before a fault escalates to a trip event.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSM142120R1201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230…400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.105 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542058007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Verified RoHS compliance declaration for the European market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered and compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 62020:\u003c\/strong\u003e Designed and tested to IEC EN 62020 — the international standard for residual current monitors (RCMs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 62020:\u003c\/strong\u003e Meets the European harmonised standard for electrical accessories and residual current monitors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB RD2 residual current monitoring relay is widely deployed in industrial automation, commercial building management, and infrastructure applications where continuous leakage current surveillance is critical. Typical applications include monitoring of motor feeder circuits, IT and TN earthing systems, uninterruptible power supplies (UPS), data centre power distribution, HVAC control panels, and process manufacturing lines where unplanned shutdowns must be avoided. By providing an early warning output before the leakage current reaches the disconnection threshold, the RD2 enables maintenance teams to schedule corrective action without interrupting production.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025571099,"sku":"2CSM142120R1201","price":163.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csm142120r1201-rd2-abb-2csm142120r1201-rd2_f8e1c2c1-053a-4977-aadd-92bf214cc9df.webp?v=1777393366"},{"product_id":"abb-2csj201001r0002-rd3-500ma-residual-current-monitor","title":"ABB 2CSJ201001R0002 RD3 Type A 500mA 230-400V AC 3.6W Residual Current Monitor","description":"\u003cp\u003eThe ABB RD3 (2CSJ201001R0002) is a Type A Residual Current Monitor designed to continuously supervise earth leakage currents in AC electrical installations. The RD3 operates across a rated voltage range of 230–400 V AC, responds at an adjustable threshold of 500 mA, and consumes only 3.6 W — making it a compact, energy-efficient solution for panel builders and maintenance engineers who need reliable insulation fault detection. Certified to IEC EN 60947-2 and carrying CE and RoHS marks, the ABB RD3 is ready for deployment in industrial control panels and building automation systems worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ201001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Value (Residual Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230...400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542734833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable EU harmonisation legislation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS2 directive compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU Commission Delegated Directive (RoHS3) compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit-breakers standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant disposal marking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eContinuous earth leakage monitoring in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eInsulation fault detection in manufacturing and process automation environments\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems requiring residual current supervision\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance monitoring to reduce unplanned downtime\u003c\/li\u003e\n\u003cli\u003eProtection of sensitive equipment where nuisance tripping from conventional RCDs must be avoided\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025702171,"sku":"2CSJ201001R0002","price":223.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj201001r0002-rd3-abb-2csj201001r0002-rd3_8cf7624d-ca67-48c8-9342-d2e45e047b7b.webp?v=1777393374"},{"product_id":"abb-2csj202001r0002-rd3m-residual-current-monitoring-relay","title":"ABB 2CSJ202001R0002 RD3M 1-500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD3M (2CSJ202001R0002) is a DIN-rail mounted residual current monitoring relay designed to continuously supervise insulation integrity and detect earth leakage currents in AC electrical installations. Part of the ABB RD3 series, the RD3M provides adjustable sensitivity from 1 to 500 mA at rated voltages of 230 to 400 V AC, making it suitable for early fault detection in control panels, machinery, and distribution systems. Rated at just 3.6 W power consumption, this compact unit measures 52.8 × 85 × 65 mm and weighs only 223 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ202001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA (adjustable 1–500 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 … 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542747031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS recast directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliance with updated RoHS substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2 Annex M:\u003c\/strong\u003e Residual current device requirements per IEC\/EN 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e European harmonised standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB RD3M residual current monitoring relay is ideal for continuous earth leakage monitoring in industrial control panels, building electrical installations, and machine tool enclosures. Its wide adjustable current range (1–500 mA) enables both sensitive insulation monitoring for critical equipment and higher-threshold monitoring for general distribution boards. The DIN-rail form factor integrates seamlessly into standard control cabinets, supporting proactive maintenance strategies by providing early warning of insulation degradation before nuisance tripping or equipment damage occurs.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025767707,"sku":"2CSJ202001R0002","price":354.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj202001r0002-rd3m-abb-2csj202001r0002-rd3m_f5bbe89b-20fd-4764-9a70-4bbe81e0d71d.webp?v=1777393382"},{"product_id":"abb-2csj203001r0002-rd3p-residual-current-monitoring-relay","title":"ABB 2CSJ203001R0002 RD3P 500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay","description":"\u003cp\u003eThe ABB RD3P (SKU: 2CSJ203001R0002) is a Type A residual current monitoring relay designed to continuously supervise insulation integrity and detect earth fault currents in AC electrical installations. Part of the ABB RD3 series, the RD3P monitors leakage currents up to 500 mA across a rated voltage range of 230–400 V AC and mounts directly on standard DIN rail, making it an ideal solution for industrial control panels, distribution boards, and automation systems where earth fault detection is critical for personnel safety and equipment protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSJ203001R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230–400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.8 mm × 85 mm × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542733836\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Compliance with the European Union RoHS Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the RoHS amendment expanding restricted substances list\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2 Ann M:\u003c\/strong\u003e Meets Annex M requirements for residual current protection devices under IEC EN 60947-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC EN 60947-2:\u003c\/strong\u003e Certified to the international standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-2:\u003c\/strong\u003e Compliant with the European harmonised standard for low-voltage circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth fault and leakage current monitoring in industrial control panels\u003c\/li\u003e\n\u003cli\u003eInsulation supervision in distribution boards and motor control centres\u003c\/li\u003ecatch\u003cli\u003ePersonnel protection in automation and process control systems\u003c\/li\u003e\n\u003cli\u003eContinuous residual current monitoring in commercial and industrial buildings\u003c\/li\u003e\n\u003cli\u003eIntegration with PLCs and SCADA systems via relay output signalling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229025833243,"sku":"2CSJ203001R0002","price":361.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csj203001r0002-rd3p-abb-2csj203001r0002-rd3p_36619c87-3f36-4cda-be6f-7c57b1b468d8.webp?v=1777393386"},{"product_id":"schneider-electric-lv481001-vigirex-rhus","title":"Schneider Electric LV481001 Vigirex RHUs 30 mA-30 A 0-4.5 s 220-240 V AC Residual Current Monitoring Relay","description":"\u003cp\u003eThe Schneider Electric LV481001 Vigirex RHUs is a front-panel-mounting residual current protection relay rated 220\/240 V AC, with earth-leakage sensitivity adjustable from 30 mA to 30 A and a 0 to 4.5 s time delay. It is a type A relay that trips the associated circuit breaker via a compatible toroid when the set threshold is exceeded, and can also drive a separate pre-alarm.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigirex RHUs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual current protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03-1 A (step 0.001 A); 1-30 A (step 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage time delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous at 0.03 A; adjustable 0-4.5 s for 0.03-30 A (step 10 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC 50\/60 Hz (70-110%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored distribution system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V AC at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTT, IT, TN-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal, remote test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O alarm (fail-safe); 1 NO pre-alarm (fail-safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 x 72 x 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60755\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe RHUs is the non-communicating version of the Vigirex RHU family: choose it for a standalone panel where Modbus reporting is not needed, and step up to the RHU when SCADA or BMS integration via Modbus is required. Its type A protection class covers both AC and pulsating DC residual currents, and the field-adjustable 30 mA to 30 A sensitivity lets one relay cover applications from personnel protection (30 mA) up to fire and equipment protection (up to 30 A). The manual reset after a fault forces a deliberate acknowledgement before the protected circuit is re-energised.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229501985051,"sku":"LV481001","price":548.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481001-vigirex-rhus-residual-current-relay.jpg?v=1790869418"},{"product_id":"schneider-electric-lv481003-vigirex-rhu","title":"Schneider Electric LV481003 Vigirex RHU Modbus 30 mA-30 A 220-240 V AC Residual Current Monitoring Relay","description":"\u003cp\u003eThe Schneider Electric LV481003 Vigirex RHU is a front-panel-mounting, Modbus-communicating residual current protection relay rated 220\/240 V AC, with earth-leakage sensitivity adjustable from 30 mA to 30 A and a 0 to 4.5 s time delay. It is a type A relay that trips the associated circuit breaker via a compatible toroid when the set threshold is exceeded, and reports status over Modbus slave communication.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigirex RHU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual current protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeypad, Modbus address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03-1 A (step 0.001 A); 1-30 A (step 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage time delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous at 0.03 A; adjustable 0-4.5 s for 0.03-30 A (step 10 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC 50\/60 Hz (70-110%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored distribution system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V AC at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTT, TN-S, IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal, remote test, remote test via communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication service\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O alarm (fail-safe); 1 NO pre-alarm (fail-safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 x 72 x 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60755\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe RHU adds Modbus slave communication and remote reset\/test to the same type A, 30 mA to 30 A protection function as the non-communicating RHUs; choose it when the relay has to report status and alarms into a Smart Panel or Modbus-based supervisory system instead of being read locally. Remote reset means a fault can be acknowledged from the control system rather than requiring a technician at the panel face, which matters for unattended or remotely supervised switchboards. The same type A class and adjustable 0-4.5 s time delay as the RHUs support selective coordination between upstream and downstream earth-leakage relays.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229502050587,"sku":"LV481003","price":570.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481003-vigirex-rhu-residual-current-relay.jpg?v=1790869427"},{"product_id":"schneider-electric-lv481004-vigirex-rmh","title":"Schneider Electric LV481004 Vigirex RMH 30 mA-30 A 220-240 V AC Multiplexed Residual Current Monitoring Relay","description":"\u003cp\u003eThe Schneider Electric LV481004 Vigirex RMH is a front-panel-mounting residual current monitoring relay rated 220\/240 V AC that tracks insulation degradation from cable or extension ageing. Used with a VigiPacT RM12T multiplexer for up to 12 measurement channels, it issues a control signal when the per-channel residual current, adjustable from 30 mA to 30 A, exceeds the set threshold.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigirex RMH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitoring relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeypad, Modbus address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage sensitivity (per channel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03-1 A (step 0.001 A); 1-30 A (step 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage time delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous at 0.03 A; adjustable 0-4.5 s for 0.03-30 A (step 10 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent sensors \/ multiplexer compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigiPacT TOA, A and L sensors; VigiPacT RM12T multiplexer (up to 12 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC 50\/60 Hz (70-110%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored distribution system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V AC at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTN-S, IT, TT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal, remote test via communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication service\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O alarm (fail-safe); 1 NO pre-alarm (fail-safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 x 72 x 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60755\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe RMH is a monitoring relay, not a protection relay: it issues an alarm signal but does not itself trip the associated circuit breaker, so pick the RHU or RHUs instead where automatic tripping on a residual-current fault is required. Pairing it with the RM12T multiplexer lets one RMH watch up to 12 separate feeders for early insulation degradation, which suits preventive-maintenance monitoring across a distribution board rather than single-circuit protection. Automatic reset after a fault clears keeps the monitoring loop running without a manual step at the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229502116123,"sku":"LV481004","price":639.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481004-vigirex-rmh-monitoring-relay.jpg?v=1790869436"},{"product_id":"schneider-electric-lv481010-vigirex-rhb","title":"Schneider Electric LV481010 Vigirex RHB Type B 30 mA-3 A 100-250 V AC\/DC Residual Current Monitoring Relay","description":"\u003cp\u003eThe Schneider Electric LV481010 Vigirex RHB is a DIN-rail-mounting residual current protection relay rated 100 to 250 V AC\/DC, with earth-leakage sensitivity adjustable from 30 mA to 3 A and a delay adjustable from instantaneous up to 10 s. It is a type B relay, so it detects smooth DC residual currents in addition to AC and pulsating DC, and trips the associated circuit breaker via a compatible type B toroid when the set threshold is exceeded.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVigirex RHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual current protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage protection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03-0.1 A (step 0.001 A); 0.1-1 A (step 0.01 A); 1-3 A (step 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth-leakage time delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous at 0.03 A; adjustable 0-1 s (step 10 ms) and 1-10 s (step 100 ms) for 0.03-3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V AC 50-400 Hz (70-120%) or 100-250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ithe] Conventional enclosed thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored distribution system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 800 V AC, 0-2000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTT, TN-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote test, local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous electronics, power supply and relay\/sensor link watchdog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\/NC alarm (fail-safe); 1 NO pre-alarm (fail-safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 x 90 x 70.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-2 Annex M\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60755\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe RHB is the DIN-rail, type B member of the Vigirex family, built for cabinets where a front-panel cutout isn't wanted; the front-panel-mount RHUs\/RHU cover type A applications instead. Its type B class is the deciding factor versus the type A relays: pick the RHB where downstream equipment (variable speed drives, UPS, EV chargers) can generate smooth DC earth-fault currents that a type A relay cannot detect. Continuous self-monitoring of the electronics, power supply and sensor link, combined with remote reset, suits unattended installations where a latent relay fault needs to be flagged rather than discovered at the next real fault.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229502181659,"sku":"LV481010","price":998.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481010-vigirex-rhb-residual-current-relay.jpg?v=1790869446"},{"product_id":"schneider-a9r41425-iid-4p-25a-10ka-rccb-earth-leakage","title":"Schneider Electric A9R41425 iID 4P 25A 10kA 400\/415V AC Earth Leakage Protection RCCB DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9R41425 iID is a 4-pole 25A earth leakage protection device (RCCB) from the Acti9 series, designed for reliable fault current detection and personnel protection in industrial and commercial installations. Rated at 400\/415V AC with a breaking capacity of 10kA, this DIN rail-mounted unit complies with IEC 61008-1 and EN 61008-1 standards, making it suitable for demanding control panel applications across a wide range of sectors.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA9R41425\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eiID\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActi9\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarth Leakage Protection (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400\/415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91 mm x 72 mm x 73.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-1:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008-1:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008-1, confirming compliance for CE marking within the EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear, ensuring robust performance in industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance — product is free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substance safety in electrical components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonnel and equipment protection against earth leakage currents in commercial buildings and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eResidual current protection in 3-phase + neutral distribution boards and control panels\u003c\/li\u003e\n  \u003cli\u003eIntegration with Acti9 modular DIN rail systems for compact switchboard assemblies\u003c\/li\u003e\n  \u003cli\u003eFault current detection in automation and motor control circuits rated up to 415V AC\u003c\/li\u003e\n  \u003cli\u003eCompliance-driven installations requiring IEC 61008-1 \/ EN 61008-1 certified protection devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229898477851,"sku":"A9R41425","price":52.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-a9r41425-rccb-din-rail_f050752c-637b-4602-8830-2a001266a339.jpg?v=1777163759"},{"product_id":"siemens-5sv8000-6kk-5sv8-0-03a-230v-residual-current-device","title":"Siemens 5SV8000-6KK 5SV8 0.03A 230V Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8000-6KK is a residual current monitor from the SENTRON\/SIRIUS 5SV8 series. Differential current monitoring device analog, Type A IDN 0.03A 5A 0.02 5 sec. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8000-6KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eresidual current monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog, type A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-scale value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8700-0KK, 5SV8701-0KK, 5SV8702-0KK, 5SV8703-0KK, 5SV8704-0KK, 5SV8705-0KK, 5SV8706-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated value minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP on the front\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP41\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [V∙A] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of CO contacts for auxiliary contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.187 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8000-6KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031721755,"sku":"5SV8000-6KK","price":271.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8000-6kk.webp?v=1784377741"},{"product_id":"siemens-5sv8001-6kk-5sv8-0-03a-230v-residual-current-device","title":"Siemens 5SV8001-6KK 5SV8 0.03A 230V Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8001-6KK is a residual current monitor from the SENTRON\/SIRIUS 5SV8 series. Differential current monitoring device Digital, Type A IDN 0.03 A 30 A 0.02 10 sec. (INS, SEL). Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8001-6KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eresidual current monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital, type A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-scale value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8700-0KK, 5SV8701-0KK, 5SV8702-0KK, 5SV8703-0KK, 5SV8704-0KK, 5SV8705-0KK, 5SV8706-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated value minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP on the front\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP41\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [V∙A] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of CO contacts for auxiliary contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.267 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8001-6KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031754523,"sku":"5SV8001-6KK","price":328.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8001-6kk.webp?v=1784377749"},{"product_id":"siemens-5sv8702-0kk-5sv8-80a-residual-current-device","title":"Siemens 5SV8702-0KK 5SV8 80A Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8702-0KK is a summation current transformer from the SENTRON\/SIRIUS 5SV8 series. Summation current transformer 35 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8702-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esummation current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etype A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual current (Idn) minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal diameter of summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire length maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational current rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 50 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 60 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efor AC power system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function error memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable conductor cross-sections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 mm²  2.1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8702-0KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031787291,"sku":"5SV8702-0KK","price":102.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8702-0kk.webp?v=1784377756"},{"product_id":"siemens-5sv8703-0kk-5sv8-200a-residual-current-device","title":"Siemens 5SV8703-0KK 5SV8 200A Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8703-0KK is a summation current transformer from the SENTRON\/SIRIUS 5SV8 series. Summation current transformer 70 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8703-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esummation current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etype A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual current (Idn) minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal diameter of summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire length maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational current rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 50 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 60 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efor AC power system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function error memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable conductor cross-sections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 mm²  2.1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.298 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8703-0KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031820059,"sku":"5SV8703-0KK","price":139.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8703-0kk.webp?v=1784377764"},{"product_id":"siemens-5sv8704-0kk-5sv8-250a-residual-current-device","title":"Siemens 5SV8704-0KK 5SV8 250A Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8704-0KK is a summation current transformer from the SENTRON\/SIRIUS 5SV8 series. Summation current transformer 105 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8704-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esummation current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etype A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual current (Idn) minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal diameter of summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire length maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational current rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 50 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 60 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efor AC power system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function error memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable conductor cross-sections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 mm²  2.1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.512 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8704-0KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031852827,"sku":"5SV8704-0KK","price":213.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8704-0kk.webp?v=1784377774"},{"product_id":"siemens-5sv8705-0kk-5sv8-500a-residual-current-device","title":"Siemens 5SV8705-0KK 5SV8 500A Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8705-0KK is a summation current transformer from the SENTRON\/SIRIUS 5SV8 series. Summation current transformer 140 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8705-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esummation current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etype A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual current (Idn) minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal diameter of summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire length maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational current rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 50 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 60 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efor AC power system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function error memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable conductor cross-sections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 mm²  2.1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.081 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8705-0KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031885595,"sku":"5SV8705-0KK","price":445.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8705-0kk.webp?v=1784377782"},{"product_id":"siemens-5sv8706-0kk-5sv8-630a-residual-current-device","title":"Siemens 5SV8706-0KK 5SV8 630A Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8706-0KK is a summation current transformer from the SENTRON\/SIRIUS 5SV8 series. Summation current transformer 210 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8706-0KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esummation current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003etype A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual current (Idn) minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal diameter of summation current transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire length maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP at connection all terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the operating voltage for actuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational current rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 50 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC at 60 Hz rated value maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efor AC power system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function error memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connectable conductor cross-sections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 mm²  2.1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8706-0KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031918363,"sku":"5SV8706-0KK","price":659.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8706-0kk.webp?v=1784377790"},{"product_id":"siemens-5sv8900-1kk-5sv8-residual-current-device","title":"Siemens 5SV8900-1KK 5SV8 Residual Current Device","description":"\u003cp\u003eThe Siemens 5SV8900-1KK is a holder from the SENTRON\/SIRIUS 5SV8 series. SENTRON, holder, for transformer mounting. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8900-1KK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5SV8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Device\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolder\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor transformer mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolder\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 5SV8900-1KK is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 5SV8 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620031951131,"sku":"5SV8900-1KK","price":10.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-5sv8900-1kk.webp?v=1784377796"}],"url":"https:\/\/stoklink.com\/collections\/rcd-modules.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}