{"title":"RCCB (Residual Current Circuit Breakers)","description":"\u003cp\u003eResidual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.\u003c\/li\u003e\n\u003cli\u003eSchneider Electric Acti 9 iID and Easy9 RCCBs.\u003c\/li\u003e\n\u003cli\u003eType B devices for drive circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRated current: at least the total load current of the downstream circuits.\u003c\/li\u003e\n\u003cli\u003eSensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.\u003c\/li\u003e\n\u003cli\u003eType: AC for resistive loads, A for electronics, B for drives and inverters.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.\u003c\/li\u003e\n\u003cli\u003ePoles: 2P for single-phase, 4P for three-phase with neutral.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eCan an RCCB replace an MCB?\u003c\/h3\u003e\u003cp\u003eNo. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.\u003c\/p\u003e\u003ch3\u003eWhat does Type A mean on an RCCB?\u003c\/h3\u003e\u003cp\u003eType A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.\u003c\/p\u003e\u003ch3\u003eCan I order RCCBs for a project in bulk?\u003c\/h3\u003e\u003cp\u003eYes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.\u003c\/p\u003e","products":[{"product_id":"abb-2csf202004r1250-fh202-ac-25-0-03-2p-25a-rccb","title":"ABB 2CSF202004R1250 FH202 AC-25\/0.03 2P 25A 6kA 30mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH202 AC-25\/0.03 (SKU: 2CSF202004R1250) is a 2-pole residual current circuit breaker from the FH200 series, rated at 25 A with a 30 mA trip sensitivity and 6 kA breaking capacity, designed for DIN rail installation in residential and light-commercial distribution boards. The FH202 AC-25\/0.03 provides reliable protection against earth leakage faults caused by alternating sinusoidal currents (Type AC), safeguarding personnel and equipment in control panels and final circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202004R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCB devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for residual current circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit-breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination standard for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Directive 2012\/19\/EU on waste electrical and electronic equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth leakage protection in residential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003ePersonnel protection against electric shock in final circuits up to 25 A\u003c\/li\u003e\n\u003cli\u003eDIN rail-mounted installations in light-commercial and industrial control panels\u003c\/li\u003e\n\u003cli\u003eProtection of circuits supplying bathrooms, kitchens, and outdoor socket outlets\u003c\/li\u003e\n\u003cli\u003eSupplementary earth fault protection downstream of main switchgear\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993294619,"sku":"2CSF202004R1250","price":27.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202004r1250-fh202-ac-25-0-03-current-circuit-breaker_c8d026fd-c252-45ab-ac17-ef3760df283a.webp?v=1777162695"},{"product_id":"abb-2csf202004r1400-fh202-ac-40-0-03-2p-40a-rccb","title":"ABB 2CSF202004R1400 FH202 AC-40\/0.03 2P 40A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB FH202 AC-40\/0.03 (SKU: 2CSF202004R1400) is a 2-pole, 40 A residual current circuit breaker (RCCB) from the FH200 series, designed to provide reliable earth-fault and personal-shock protection in residential and light commercial installations. With a 30 mA rated residual current and DIN-rail mounting, this RCCB fits seamlessly into standard distribution boards and satisfies IEC 61008 and EN 61008 requirements for residual current operated circuit breakers without integral overcurrent protection.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202004R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893707\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008 \/ EN 61008 \/ IEC\/EN61008:\u003c\/strong\u003e International and European standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1 \/ EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be reused, recycled, and recovered\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonal shock and earth-fault protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eLight commercial and industrial control panels requiring DIN-rail mounted RCCBs\u003c\/li\u003e\n  \u003cli\u003eProtection of socket-outlet circuits per IEC wiring regulations\u003c\/li\u003e\n  \u003cli\u003eDownstream protection in sub-distribution boards alongside MCBs\u003c\/li\u003e\n  \u003cli\u003eCompliance-driven installations requiring IEC 61008-certified residual current devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993360155,"sku":"2CSF202004R1400","price":29.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202004r1400-fh202-ac-40-0-03-circuit-breaker-rccb_651c9789-e421-4175-a858-0f691c49c5ea.webp?v=1777162701"},{"product_id":"abb-2csf202004r1630-fh202-ac-63-0-03-2p-63a-rccb","title":"ABB 2CSF202004R1630 FH202 AC-63\/0.03 2P 63A 30mA 6kA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH202 AC-63\/0.03 (SKU: 2CSF202004R1630) is a 2-pole 63 A residual current circuit breaker (RCCB) from the FH200 series, designed to provide reliable personal protection against earth leakage currents with a 30 mA sensitivity threshold. Featuring a 6 kA breaking capacity and Type AC detection, the FH202 AC-63\/0.03 trips on sinusoidal alternating residual currents, making it ideal for standard residential, commercial, and light industrial installations. DIN rail mounting and compact 35 × 85 × 69 mm dimensions ensure straightforward integration into standard distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202004R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC (sinusoidal AC residual currents)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008 \/ EN 61008 \/ IEC\/EN 61008:\u003c\/strong\u003e Core standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs) — confirms device performance, tripping accuracy, and safety under fault conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations — verifies compatibility in standard distribution systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1 \/ EN 60664-1:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment — ensures correct creepage and clearance distances for rated insulation voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for the ecodesign of energy-related products — confirms environmentally responsible product design and end-of-life considerations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — product is free from restricted hazardous materials including lead, mercury, cadmium, and hexavalent chromium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance — substances of very high concern (SVHCs) controlled within permissible limits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance — product is registered for proper recycling and disposal at end of life\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993458459,"sku":"2CSF202004R1630","price":36.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202004r1630-fh202-ac-63-0-03-current-circuit-breaker_1106434c-33c2-49dd-b6e0-c4e27cf5ad52.webp?v=1777162709"},{"product_id":"abb-2csf202003r3250-fh202-ac-25-0-3-2p-25a-rccb","title":"ABB 2CSF202003R3250 FH202 AC-25\/0.3 2P 25A RCCB Residual Current Circuit Breaker DIN Rail","description":"\u003cp\u003eThe ABB FH202 AC-25\/0.3 residual current circuit breaker (RCCB), SKU 2CSF202003R3250, is a 2-pole 25A device from the FH200 series engineered to provide reliable earth-fault and residual-current protection in residential, commercial, and light-industrial installations. Rated at 25A with a 300mA trip sensitivity, the FH202 AC-25\/0.3 mounts directly on standard DIN rail and complies with IEC 61008 and EN 61008, making it suitable for use throughout IEC-governed electrical systems worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-25\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202003R3250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA (0.3 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, equivalent to IEC 61008\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN certification for RCCB design and performance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European harmonized standard for insulation coordination in low-voltage installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-72:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential consumer unit and distribution board earth-fault protection\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection against residual currents\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panel earth-leakage protection\u003c\/li\u003eDownstream protection of socket-outlet circuits requiring 300mA sensitivity\u003cli\u003eCompliance with IEC 61008 installation requirements in low-voltage distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993556763,"sku":"2CSF202003R3250","price":25.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202003r3250-fh202-ac-25-0-3-breaker-din-rail_a7e4b95b-e255-4dd6-9d28-31a91cac4bd0.webp?v=1777162674"},{"product_id":"abb-2csf202003r3400-fh202-ac-40-0-3-2p-40a-rccb","title":"ABB 2CSF202003R3400 FH202 AC-40\/0.3 2P 40A 300mA DIN-Rail Residual Current Circuit Breaker RCCB","description":"\u003cp\u003eThe ABB FH202 AC-40\/0.3 (SKU: 2CSF202003R3400) is a 2-pole 40 A residual current circuit breaker (RCCB) from the ABB FH200 series, designed to provide reliable earth-fault protection in residential and light commercial installations. Rated at 300 mA sensitivity and mounting directly onto standard DIN-rail, this RCCB detects leakage currents and disconnects the circuit to protect personnel and equipment from electric shock hazards. Compact at 35 mm × 85 mm × 69 mm and weighing just 200 g, the FH202 AC-40\/0.3 is an ideal choice for space-constrained distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202003R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893103\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs — equivalent to IEC 61008\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN designation confirming dual compliance for RCCBs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit-breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination standard for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European harmonised insulation coordination standard for low-voltage installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e European standard for general requirements on end-of-life treatment of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993622299,"sku":"2CSF202003R3400","price":26.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202003r3400-fh202-ac-40-0-3-circuit-breaker-rccb_4e35c8e3-6325-4ef0-8dd7-9b26ec1cc2fc.webp?v=1777162681"},{"product_id":"abb-2csf202003r3630-fh202-ac-63-0-3-2p-63a-rccb","title":"ABB 2CSF202003R3630 FH202 AC-63\/0.3 2P 63A 6kA DIN Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB FH202 AC-63\/0.3 (SKU: 2CSF202003R3630) is a 2-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 63 A with a 300 mA sensitivity and a breaking capacity of 6 kA, designed for DIN rail mounting in residential, commercial, and light industrial control panels. The FH202 AC-63\/0.3 provides reliable earth-fault protection against electric shock and fire hazards, complying with IEC 61008 and EN 61008 international standards. Compact at 35 mm × 85 mm × 69 mm and weighing just 200 g, it integrates seamlessly into standard distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 AC-63\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202003R3630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893202\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNF FR:\u003c\/strong\u003e French national certification mark for electrical equipment conformity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOFT AU:\u003c\/strong\u003e Australian conformity mark for electrical safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC\/EN compliance for RCCB performance and safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-72:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European standard for residual current circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets all applicable EU directives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-fault and personal electric-shock protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical installations requiring 63 A 2-pole RCCB protection\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels with DIN rail assembly\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits supplying bathrooms, kitchens, and outdoor sockets\u003c\/li\u003e\n  \u003cli\u003eSupplementary earth-leakage protection in switchgear assemblies alongside MCBs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993687835,"sku":"2CSF202003R3630","price":32.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202003r3630-fh202-ac-63-0-3-circuit-breaker-rccb_77bb314a-ddc3-4c89-bd1e-b1013ff9e361.webp?v=1777162689"},{"product_id":"abb-2csf204004r1250-fh204-ac-25-0-03-4p-rccb","title":"ABB 2CSF204004R1250 FH204 AC-25\/0.03 4P 25A 6kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.03 (SKU: 2CSF204004R1250) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25 A with a 30 mA sensitivity and a breaking capacity of 6 kA. Designed for DIN rail installation, the FH204 AC-25\/0.03 provides reliable earth fault protection in residential, commercial, and light industrial distribution boards, safeguarding both personnel and equipment against ground leakage currents.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204004R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards requiring earth fault protection on 4-wire (3-phase + neutral) circuits\u003c\/li\u003e\n\u003cli\u003eCommercial buildings: offices, retail, and hospitality installations where personnel protection is mandatory\u003c\/li\u003e\n\u003cli\u003eLight industrial panels and machinery where 30 mA sensitivity is specified for operator safety\u003c\/li\u003e\n\u003cli\u003eSupplementary protection in combination with MCBs in TT and TN earthing systems\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and outdoor circuit protection per IEC 61008 requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993753371,"sku":"2CSF204004R1250","price":36.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204004r1250-fh204-ac-25-0-03-current-circuit-breaker.webp?v=1777162819"},{"product_id":"abb-2csf204004r1400-fh204-ac-40-0-03-4p-40a-rccb","title":"ABB 2CSF204004R1400 FH204 AC-40\/0.03 4P 40A 6kA 30mA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-40\/0.03 (SKU: 2CSF204004R1400) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 40A with a 30mA trip sensitivity and a 6kA breaking capacity. Designed for DIN rail installation in industrial and commercial control panels, this Type AC device delivers reliable earth-fault and leakage-current protection in accordance with IEC 61008 and EN 61008 standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204004R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542894001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (Trip Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008 \/ EN 61008:\u003c\/strong\u003e Core international and European standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — free from restricted materials including lead, cadmium, and mercury\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-fault and leakage-current protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003ePersonnel protection against indirect contact in commercial and light-industrial installations\u003c\/li\u003e\n\u003cli\u003eProtection of downstream circuits in 3-phase + neutral (4-wire) systems\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC electrical distribution panels\u003c\/li\u003e\n\u003cli\u003eRetrofit and replacement in existing FH200 series switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993818907,"sku":"2CSF204004R1400","price":37.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204004r1400-fh204-ac-40-0-03-current-circuit-breaker_1a8bf60d-cb60-4867-950c-03fb998bf542.webp?v=1777162826"},{"product_id":"abb-2csf204004r1630-fh204-ac-63-0-03-4p-63a-rccb","title":"ABB 2CSF204004R1630 FH204 AC-63\/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-63\/0.03 (SKU: 2CSF204004R1630) is a 4-pole residual current circuit breaker (RCCB) from the ABB FH200 series, rated at 63 A with a 30 mA trip sensitivity for Type AC earth-fault protection. Designed for DIN-rail installation, the FH204 AC-63\/0.03 provides reliable personnel and installation protection in industrial control panels, commercial distribution boards, and building automation systems where earth-leakage detection is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204004R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542894100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for residual current circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against electric shock in industrial control panels\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection in commercial and residential distribution boards\u003c\/li\u003e\n\u003cli\u003e4-pole switching for three-phase + neutral circuits requiring residual current monitoring\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems requiring IEC 61008-compliant earth-fault protection\u003c\/li\u003e\n\u003cli\u003eMachine tool and automation control cabinets where Type AC sinusoidal earth-fault detection is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993917211,"sku":"2CSF204004R1630","price":47.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204004r1630-fh204-ac-63-0-03-current-circuit-breaker_56034e81-1501-4fa4-a9f8-930c04c7c225.webp?v=1777162837"},{"product_id":"abb-2csf204003r3250-fh204-ac-25-0-3-4p-25a-rccb","title":"ABB 2CSF204003R3250 FH204 AC-25\/0.3 4P 25A 300mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.3 (SKU: 2CSF204003R3250) is a 4-pole residual current circuit breaker (RCCB) rated at 25 A with a 300 mA trip sensitivity, designed for reliable earth-fault and personal protection in industrial and commercial installations. Part of the ABB FH200 series, this DIN-rail mounted device provides Type AC protection — detecting sinusoidal alternating residual currents — making it suitable for a wide range of standard electrical distribution applications. Compact at 70 mm × 85 mm × 69 mm and weighing just 380 g, the FH204 AC-25\/0.3 fits easily into standard control panels and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-25\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204003R3250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Trip Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC (sinusoidal alternating residual current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European standard for residual current circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-fault protection in residential distribution boards and commercial panels\u003c\/li\u003e\n\u003cli\u003ePersonal protection against indirect contact in 3-phase + neutral (4-wire) systems\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring DIN-rail mounted residual current protection\u003c\/li\u003e\n\u003cli\u003eSupplementary protection alongside MCBs in building services and facility management\u003c\/li\u003e\n\u003cli\u003eStandard AC sinusoidal leakage current detection in HVAC, lighting, and general power circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228993982747,"sku":"2CSF204003R3250","price":32.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204003r3250-fh204-ac-25-0-3-current-circuit-breaker_3a2c909d-f371-48a8-9c04-2563200e10f1.webp?v=1777162802"},{"product_id":"abb-2csf204003r3400-fh204-ac-40-0-3-4p-40a-rccb","title":"ABB 2CSF204003R3400 FH204 AC-40\/0.3 4P 40A 300mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-40\/0.3 (SKU: 2CSF204003R3400) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 40A with a 300mA Type AC residual current sensitivity for robust personnel and installation protection. Designed for DIN-rail mounting in industrial and commercial control panels, the FH204 AC-40\/0.3 provides reliable detection of sinusoidal alternating fault currents, making it an ideal choice for a wide range of electrical distribution and automation applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204003R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC (sinusoidal alternating fault current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, equivalent to IEC 61008\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB design and performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against indirect contact in industrial control panels\u003c\/li\u003e\n\u003cli\u003eEarth fault protection in commercial electrical distribution boards\u003c\/li\u003e\n\u003cli\u003eFire protection in installations with high earth leakage risk\u003c\/li\u003e\n\u003cli\u003eFour-pole RCCB solution for three-phase + neutral distribution circuits\u003c\/li\u003e\n\u003cli\u003eBuilding automation and industrial automation switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994048283,"sku":"2CSF204003R3400","price":34.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204003r3400-fh204-ac-40-0-3-current-circuit-breaker_3d13c941-d4b4-477c-a401-8cdabf2ab568.webp?v=1777162807"},{"product_id":"abb-2csf204003r3630-fh204-ac-63-0-3-4p-63a-rccb","title":"ABB 2CSF204003R3630 FH204 AC-63\/0.3 4P 63A 6kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 AC-63\/0.3 (SKU: 2CSF204003R3630) is a 4-pole residual current circuit breaker (RCCB) rated at 63 A with a 300 mA sensitivity and a 6 kA breaking capacity, designed for DIN rail installation in industrial and commercial control panels. Part of the ABB FH200 series, this RCCB provides reliable protection against earth leakage currents in three-phase AC systems, safeguarding both personnel and equipment. The FH204 AC-63\/0.3 meets rigorous international standards, making it a trusted choice for engineers and procurement professionals worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 AC-63\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204003R3630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542893509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNF FR:\u003c\/strong\u003e French national certification mark confirming compliance with applicable French standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFT AU:\u003c\/strong\u003e Australian certification mark for regulatory compliance in the Australian market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs) for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN designation for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — confirms product is free from restricted materials including lead, mercury, and cadmium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — confirms compliance with substance restrictions in articles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003ePersonnel protection against indirect contact in three-phase AC installations\u003c\/li\u003e\n\u003cli\u003eCommercial and light industrial building electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eProtection of downstream circuits in motor control centres and machinery\u003c\/li\u003e\n\u003cli\u003eCompliant installations requiring IEC 61008 \/ EN 61008 certified residual current protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994113819,"sku":"2CSF204003R3630","price":42.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204003r3630-fh204-ac-63-0-3-current-circuit-breaker_cf40bc69-5bf5-4725-a3b4-892ae6385952.webp?v=1777162811"},{"product_id":"abb-2csf202001r1800-f202-ac-80-0-03-2p-80a-rccb","title":"ABB 2CSF202001R1800 F202 AC-80\/0.03 2P 80A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F202 AC-80\/0.03 residual current circuit breaker (RCCB), catalog number F202 AC-80\/0.03 (SKU: 2CSF202001R1800), is a 2-pole, 80A, 30mA earth leakage protection device from ABB's trusted F200 series. Designed for DIN-rail installation in industrial and commercial control panels, it provides reliable personnel and equipment protection against residual earth-fault currents, meeting the stringent requirements of IEC 61008 and EN 61008 standards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 AC-80\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202001R1800\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542914204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, ensuring compliance across EU markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard confirming resilience under climatic and mechanical stress conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing sustainability and end-of-life requirements for electrical and electronic products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard compliance for electrical grounding component assemblies, supporting North American market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified, confirming suitability for Canadian electrical installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive — free from restricted materials including lead, mercury, and cadmium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003ePersonnel protection in commercial buildings, workshops, and manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003eEquipment protection in HVAC, motor circuits, and lighting installations\u003c\/li\u003e\n  \u003cli\u003eFinal distribution circuits requiring 2-pole residual current protection up to 80A\u003c\/li\u003e\n  \u003cli\u003eApplications demanding compliance with IEC 61008 and EN 61008 in European and international markets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994179355,"sku":"2CSF202001R1800","price":73.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202001r1800-f202-ac-80-0-03-circuit-breaker-rccb_c3f3fd01-f55e-4416-81f1-797476e55683.webp?v=1777162650"},{"product_id":"abb-2csf202001r1900-f202-ac-100-0-03-2p-100a-rccb","title":"ABB 2CSF202001R1900 F202 AC-100\/0.03 2P 100A 30mA Type AC Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 AC-100\/0.03 (SKU: 2CSF202001R1900) is a 2-pole, 100 A residual current circuit breaker (RCCB) from the ABB F200 series, designed to provide reliable earth-leakage protection with a 30 mA tripping sensitivity for Type AC sinusoidal fault currents. Engineered for DIN-rail installation in industrial control panels and distribution boards, this RCCB safeguards personnel and equipment against indirect contact and residual current faults in demanding electrical environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 AC-100\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202001R1900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC (sinusoidal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542914303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008, confirming EU market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering robustness under temperature, humidity, and mechanical stress conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing end-of-life and sustainability requirements for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL certification for electrical energy storage systems, confirming safety for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval for use in Canadian electrical installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — confirms the product is free from restricted toxic materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e European chemical safety regulation compliance — no substances of very high concern above threshold limits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance — product registered for proper end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against indirect contact in residential, commercial, and industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection for circuits feeding socket outlets, lighting, and HVAC equipment\u003c\/li\u003e\n\u003cli\u003eIntegration into DIN-rail-mounted control panels alongside MCBs and contactors\u003c\/li\u003e\n\u003cli\u003eProtection of circuits where Type AC (sinusoidal) residual currents are the primary fault characteristic\u003c\/li\u003e\n\u003cli\u003eIndustrial automation panels requiring reliable 30 mA sensitivity earth-fault protection at 100 A load rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994244891,"sku":"2CSF202001R1900","price":111.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202001r1900-f202-ac-100-0-03-current-circuit-breaker_15233d96-8367-4ee0-8208-932a1016364e.webp?v=1777162656"},{"product_id":"abb-2csf202001r3800-f202-ac-80-0-3-2p-80a-rccb","title":"ABB 2CSF202001R3800 F202 AC-80\/0.3 2P 80A 300mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F202 AC-80\/0.3 (SKU: 2CSF202001R3800) is a 2-pole, 80 A residual current circuit breaker (RCCB) from the F200 series, designed to provide reliable earth-fault and personnel protection in industrial and commercial installations. Offering 300 mA sensitivity and DIN-rail mounting in a compact 35 × 85 × 69 mm footprint, the F202 AC-80\/0.3 delivers proven ABB performance in distribution boards and control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 AC-80\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202001R3800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542914600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, ensuring compliance within EU markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering operational reliability under temperature, humidity, and mechanical stress\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e End-of-life and resource efficiency standard for electrical and electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for use in North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, free from restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e European Chemical Agency compliance, confirming safe material composition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against electric shock in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth-fault protection for circuits supplying machinery, HVAC equipment, and building services\u003c\/li\u003e\n\u003cli\u003eSupplementary protection in TT and TN earthing systems\u003c\/li\u003e\n\u003cli\u003eIntegration into busbar systems and modular enclosures using standard 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003eCommercial and light-industrial installations requiring IEC 61008-compliant RCCB devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994310427,"sku":"2CSF202001R3800","price":65.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202001r3800-f202-ac-80-0-3-circuit-breaker-rccb_d302db67-3287-46d8-baee-d588a9a03d44.webp?v=1777162663"},{"product_id":"abb-2csf202001r3900-f202-ac-100-0-3-2p-100a-rccb","title":"ABB 2CSF202001R3900 F202 AC-100\/0.3 2P 100A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F202 AC-100\/0.3 residual current circuit breaker (RCCB), catalog number F202 AC-100\/0.3 (SKU 2CSF202001R3900), is a 2-pole, 100 A earth-fault protection device designed for DIN-rail installation in industrial control panels and building distribution boards. Part of ABB's proven F200 series, it provides reliable protection against residual currents caused by earth faults, safeguarding both personnel and equipment in demanding electrical installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 AC-100\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202001R3900\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA (0.3 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542914709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs) for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard equivalent to IEC 61008, confirming compliance for the EU market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing end-of-life treatment and recyclability of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials including lead, mercury, and cadmium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances in electrical components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-fault protection in industrial control panels and motor control centres\u003c\/li\u003e\n  \u003cli\u003eBuilding distribution boards requiring personnel and equipment protection\u003c\/li\u003e\n  \u003cli\u003eCommercial installations with high-current final circuits up to 100 A\u003c\/li\u003e\n  \u003cli\u003eProtection of HVAC, pump, and compressor circuits against residual currents\u003c\/li\u003e\n  \u003cli\u003eDIN-rail assemblies in automation and process control enclosures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994375963,"sku":"2CSF202001R3900","price":100.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202001r3900-f202-ac-100-0-3-circuit-breaker-rccb_a623b40d-5992-485d-8c00-86878d407425.webp?v=1777162670"},{"product_id":"abb-2csf204001r1800-f204-ac-80-0-03-4p-80a-rccb","title":"ABB 2CSF204001R1800 F204 AC-80\/0.03 4P 80A DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F204 AC-80\/0.03 (SKU: 2CSF204001R1800) is a 4-pole, 80 A residual current circuit breaker (RCCB) from the ABB F200 series, designed for reliable earth-leakage protection in industrial and commercial installations. Engineered to detect AC-type residual currents at a 30 mA sensitivity threshold, the F204 AC-80\/0.03 provides fast disconnection to protect personnel and equipment. Its compact DIN-rail mounted form factor — measuring just 70 mm × 85 mm × 69 mm — suits a wide range of control panel and distribution board applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-80\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R1800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542916604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs) for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008, confirming compliance for EU market use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standards covering climatic and mechanical robustness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard relating to end-of-life and recyclability requirements for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard covering electrical systems for electric vehicles — confirms suitability for relevant North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for the North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the EU Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003ePersonnel protection against indirect contact in commercial and light-industrial installations\u003c\/li\u003e\n\u003cli\u003eFour-pole protection for three-phase + neutral (TN, TT, and IT) electrical systems\u003c\/li\u003e\n\u003cli\u003eSupplementary residual current protection downstream of main circuit breakers\u003c\/li\u003e\n\u003cli\u003eBuilding automation, HVAC panels, and machinery enclosures requiring IEC 61008-compliant RCCB devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994441499,"sku":"2CSF204001R1800","price":95.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r1800-f204-ac-80-0-03-circuit-breaker-rccb_bc158fb8-3ba9-4f53-9fcb-ed54bc5a2274.webp?v=1777162766"},{"product_id":"abb-2csf204001r1900-f204-ac-100-0-03-4p-100a-rccb","title":"ABB 2CSF204001R1900 F204 AC-100\/0.03 4P 100A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F204 AC-100\/0.03 residual current circuit breaker (RCCB), catalog number F204 AC-100\/0.03 and SKU 2CSF204001R1900, is a 4-pole, 100 A device from the ABB F200 series designed to provide reliable earth-leakage protection in industrial and commercial installations. With a 30 mA rated residual current and DIN-rail mounting, this RCCB is engineered for control panel integration where personnel and equipment protection against earth faults is critical.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-100\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R1900\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542916703\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, ensuring compliance within the EU and EEA markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering mechanical and climatic durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing generic assessment of the service life and recyclability of energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard certification for zero-carbon footprint electrical system components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for the North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance — free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical regulation compliance, confirming absence of substances of very high concern\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance, supporting responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-leakage and personnel protection in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase and neutral circuits in commercial buildings, factories, and infrastructure\u003c\/li\u003e\n  \u003cli\u003eIntegration with downstream MCBs for combined overcurrent and residual current protection schemes\u003c\/li\u003e\n  \u003cli\u003eCompliance-driven installations requiring IEC 61008 or UL 2799 certified devices\u003c\/li\u003e\n  \u003cli\u003eDIN-rail panel assemblies where compact 70 mm width is required for space-efficient design\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994507035,"sku":"2CSF204001R1900","price":145.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r1900-f204-ac-100-0-03-circuit-breaker-rccb_441cd23a-c8eb-465f-b0ee-fee470a9b630.webp?v=1777162771"},{"product_id":"abb-2csf204001r1950-f204-ac-125-0-03-4p-125a-rccb","title":"ABB 2CSF204001R1950 F204 AC-125\/0.03 4P 125A 30mA 10kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 AC-125\/0.03 (SKU: 2CSF204001R1950) is a 4-pole residual current circuit breaker (RCCB) from the F200 series, rated at 125A with a 30mA trip sensitivity and a 10kA breaking capacity at 230\/400V AC. Designed for DIN rail installation in industrial and commercial control panels, the F204 AC-125\/0.03 provides reliable earth-fault protection against indirect contact hazards in accordance with IEC 61008 and EN 61008 standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-125\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (Trip Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 mm × 85 mm × 69.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542941507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCB devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance designation for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — restricts use of specific harmful materials in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety and registration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-fault and indirect contact protection in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of final distribution circuits in commercial and light industrial installations\u003c\/li\u003e\n\u003cli\u003eMain RCCB protection for 3-phase + neutral (4-wire) systems up to 125A\u003c\/li\u003e\n\u003cli\u003eSupplementary residual current protection alongside MCBs or MCCBs in TN and TT earthing systems\u003c\/li\u003e\n\u003cli\u003eBuilding automation, HVAC, and motor circuit protection where Type AC detection (sinusoidal residual current) is appropriate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994572571,"sku":"2CSF204001R1950","price":458.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r1950-f204-ac-125-0-03-current-circuit-breaker_58e35e01-5ee6-4172-876d-40802df2515b.webp?v=1777162776"},{"product_id":"abb-2csf204001r3800-f204-ac-80-0-3-4p-80a-rccb","title":"ABB 2CSF204001R3800 F204 AC-80\/0.3 4P 80A Residual Current Circuit Breaker (RCCB) DIN Rail","description":"\u003cp\u003eThe ABB F204 AC-80\/0.3 (SKU: 2CSF204001R3800) is a 4-pole, 80 A residual current circuit breaker (RCCB) from the ABB F200 Series, designed to provide reliable earth-fault protection in industrial and commercial control panels. Featuring DIN-rail mounting and a compact 70 mm × 85 mm × 69 mm footprint, the F204 AC-80\/0.3 is engineered for demanding installations requiring robust personnel and equipment protection against residual currents of 300 mA.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-80\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R3800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542917007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, ensuring compliance for EU installations and CE marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical robustness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard for generic assessment of the lifetime of electronic displays and related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems for electric-drive vehicles — confirms suitability for relevant North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for use in Canadian and North American electrical installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — compliant, restricting use of hazardous materials in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation ensuring chemical safety throughout the product supply chain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — registered for compliant end-of-life disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994638107,"sku":"2CSF204001R3800","price":85.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r3800-f204-ac-80-0-3-rccb-din-rail_61cd860c-ab4d-45e8-8766-cbdfadb9e271.webp?v=1777162791"},{"product_id":"abb-2csf204001r3900-f204-ac-100-0-3-4p-100a-rccb","title":"ABB 2CSF204001R3900 F204 AC-100\/0.3 4P 100A RCCB Residual Current Circuit Breaker DIN-Rail","description":"\u003cp\u003eThe ABB F204 AC-100\/0.3 (SKU: 2CSF204001R3900) is a 4-pole, 100 A residual current circuit breaker (RCCB) from the ABB F200 series, designed to provide reliable earth leakage protection in industrial and commercial control panels. With a 300 mA rated residual current and DIN-rail mounting, the F204 AC-100\/0.3 delivers safe, code-compliant disconnection against earth fault currents, protecting personnel and downstream equipment in demanding electrical installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-100\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R3900\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542917106\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs) for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, confirming compliance with EU Low Voltage Directive requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability of electrical components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard relating to end-of-life recyclability and recoverability of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification, validating suitability for Canadian and North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU on restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003ePersonnel protection against indirect contact in commercial and industrial installations\u003c\/li\u003e\n  \u003cli\u003eFour-pole protection of three-phase + neutral circuits up to 100 A\u003c\/li\u003e\n  \u003cli\u003eIntegration with MCBs in TT and TN earthing systems\u003c\/li\u003e\n  \u003cli\u003eBuilding automation, HVAC, and motor-circuit distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994703643,"sku":"2CSF204001R3900","price":131.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r3900-f204-ac-100-0-3-circuit-breaker-din-rail_dfd84e7c-5186-469a-9898-23a988f16454.webp?v=1777162795"},{"product_id":"abb-2csf204001r3950-f204-ac-125-0-3-4p-125a-rccb","title":"ABB 2CSF204001R3950 F204 AC-125\/0.3 4P 125A 300mA 10kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 AC-125\/0.3 (SKU: 2CSF204001R3950) is a 4-pole residual current circuit breaker from the ABB F200 series, rated at 125A with a 300mA tripping sensitivity and a 10kA breaking capacity at 230\/400V AC. Designed for DIN rail installation, this Type AC RCCB provides reliable earth fault protection in industrial and commercial distribution boards, safeguarding personnel and equipment against dangerous leakage currents.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-125\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R3950\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 mm × 85 mm × 69.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542941705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008, confirming compliance for EU markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN certification, confirming dual international and European compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — product is free from restricted hazardous materials including lead, mercury, and cadmium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on the registration, evaluation, authorisation, and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliance with the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault and personnel protection in three-phase distribution boards and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in commercial buildings, factories, and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eMain RCCB for downstream branch circuit protection in TN-S and TT earthing systems\u003c\/li\u003e\n  \u003cli\u003eComplementary use alongside MCBs in residential and light commercial installations requiring high-current RCCB coverage\u003c\/li\u003e\n  \u003cli\u003eControl panel and switchgear assemblies requiring DIN rail-mounted residual current protection at up to 125A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994834715,"sku":"2CSF204001R3950","price":494.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r3950-current-circuit-breaker_869a5a6f-d3b1-42bc-bb14-715ca0e4a61d.webp?v=1776943629"},{"product_id":"abb-2csf202102r1250-fh202-a-25-0-03-2p-25a-rccb","title":"ABB 2CSF202102R1250 FH202 A-25\/0.03 2P 25A 30mA 6kA Type A Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH202 A-25\/0.03 (SKU: 2CSF202102R1250) is a 2-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25A with a 30mA sensitivity for reliable personal protection and ground-fault detection in residential and light commercial installations. Delivering a 6kA breaking capacity and DIN-rail mounting, the FH202 A-25\/0.03 is engineered to disconnect circuits instantaneously upon detection of leakage currents, safeguarding both personnel and equipment from electric shock and fire risk.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 A-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202102R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, ensuring compliance across EU member states\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for residual current circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units requiring 30mA personal protection\u003c\/li\u003e\n\u003cli\u003eLight commercial and office electrical panels where Type A RCCB protection is mandated\u003c\/li\u003e\n\u003cli\u003eProtection of circuits supplying bathroom, kitchen, and outdoor socket outlets\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring compact 2-pole residual current protection on DIN-rail\u003c\/li\u003e\n\u003cli\u003eRetrofit upgrades to existing switchgear requiring IEC 61008-compliant RCCB devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994933019,"sku":"2CSF202102R1250","price":27.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202102r1250-fh202-a-25-0-03-current-circuit-breaker_0e2a0caa-5298-41b2-8250-400efc0a1d9e.webp?v=1777162713"},{"product_id":"abb-2csf202102r1400-fh202-a-40-0-03-2p-40a-rccb","title":"ABB 2CSF202102R1400 FH202 A-40\/0.03 2P 40A 6kA 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB FH202 A-40\/0.03 (SKU: 2CSF202102R1400) is a 2-pole residual current circuit breaker (RCCB) rated at 40 A with a 30 mA sensitivity and 6 kA breaking capacity, designed for reliable earth fault and personnel protection in residential and light commercial installations. Part of the ABB FH200 series, this DIN-Rail mounted RCCB provides fast disconnection upon detection of residual currents, safeguarding both equipment and personnel. Its compact 35 mm × 85 mm × 69 mm footprint and 200 g weight make it ideal for space-constrained distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 A-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202102R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, remanufactured, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU recycling and disposal regulations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995064091,"sku":"2CSF202102R1400","price":29.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202102r1400-fh202-a-40-0-03-circuit-breaker-rccb_6bf80967-ef7c-4abe-a1d8-7c30c376e476.webp?v=1777162719"},{"product_id":"abb-2csf202102r1630-fh202-a-63-0-03-2p-63a-rccb","title":"ABB 2CSF202102R1630 FH202 A-63\/0.03 2P 63A 30mA Type A Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH202 A-63\/0.03 (SKU: 2CSF202102R1630) is a 2-pole, 63A residual current circuit breaker (RCCB) from the FH200 series, providing reliable 30mA earth-fault protection against electric shock and fire hazards. Rated Type A, the FH202 A-63\/0.03 detects both sinusoidal and pulsating DC fault currents, making it ideal for modern electrical installations with electronic loads. DIN-rail mounted and IEC 61008 certified, this RCCB is engineered for residential, commercial, and light industrial control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH202 A-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202102R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A (sinusoidal + pulsating DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555-72:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be repaired and reused\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e Insulation coordination for low-voltage systems (European edition)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical systems for electric drive vehicles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units requiring personal protection against earth faults\u003c\/li\u003e\n\u003cli\u003eCommercial buildings with mixed AC and electronic loads requiring Type A fault detection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels requiring IEC 61008-compliant residual current protection\u003c\/li\u003e\n\u003cli\u003eFinal circuits supplying socket outlets, luminaires, and electronic equipment\u003c\/li\u003e\n\u003cli\u003eInstallations requiring 30mA high-sensitivity protection per IEC\/EN 61008\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995129627,"sku":"2CSF202102R1630","price":36.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202102r1630-fh202-a-63-0-03-current-circuit-breaker_cd7359c2-b3e3-43e6-b8eb-a53bc7324287.webp?v=1777162724"},{"product_id":"abb-2csf204102r1250-fh204-a-25-0-03-4p-rccb","title":"ABB 2CSF204102R1250 FH204 A-25\/0.03 4P 25A 6kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 A-25\/0.03 (SKU: 2CSF204102R1250) is a 4-pole residual current circuit breaker (RCCB) from the ABB FH200 series, rated at 25 A with a 30 mA tripping sensitivity and a 6 kA breaking capacity. Designed for DIN Rail installation, the FH204 A-25\/0.03 provides reliable protection against earth leakage faults in industrial and commercial control panel applications, helping prevent electric shock and fire hazards in three-phase and neutral distribution systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 A-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204102R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCB design and performance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to be repaired, reused, and recycled for electrical and electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance for end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth leakage and residual current protection in industrial control panels\u003c\/li\u003e\n\u003cli\u003eProtection of three-phase distribution boards in commercial and light industrial installations\u003c\/li\u003e  \u003cli\u003ePersonnel protection against electric shock in environments with 30 mA sensitivity requirements\u003c\/li\u003e\n\u003cli\u003eFire protection in electrical distribution systems where earth fault currents may ignite insulation\u003c\/li\u003e\n\u003cli\u003eIntegration into DIN Rail-mounted switchgear assemblies alongside MCBs and contactors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995195163,"sku":"2CSF204102R1250","price":36.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204102r1250-fh204-a-25-0-03-current-circuit-breaker_32332e12-42c8-49b1-9873-cea54865ec8e.webp?v=1777162844"},{"product_id":"abb-2csf204102r1400-fh204-a-40-0-03-4p-rccb","title":"ABB 2CSF204102R1400 FH204 A-40\/0.03 4P 40A 6kA 30mA Residual Current Circuit Breaker RCCB","description":"\u003cp\u003eThe ABB FH204 A-40\/0.03 (SKU: 2CSF204102R1400) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 40 A with a 30 mA trip sensitivity and 6 kA breaking capacity. Designed for DIN-Rail mounting, this RCCB provides reliable personal protection against electric shock and fire hazards in industrial and commercial control panel installations. Compact dimensions of 70 mm × 85 mm × 69 mm and a weight of 380 g make the FH204 A-40\/0.03 easy to integrate into standard distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 A-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204102R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892809\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (Trip Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonized standard for RCCBs, ensuring compliance across EU markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN compliance for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricting use of specific hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonal protection against electric shock in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eGround fault protection in commercial buildings and infrastructure projects\u003c\/li\u003e\n\u003cli\u003eFire hazard prevention in installations with ageing or damaged insulation\u003c\/li\u003e\n\u003cli\u003eFour-pole protection for three-phase + neutral circuits in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eIntegration into DIN-Rail mounted distribution boards for standard low-voltage switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995260699,"sku":"2CSF204102R1400","price":37.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204102r1400-fh204-a-40-0-03-circuit-breaker-rccb_0089b169-02e3-4716-93d8-97a450e87c23.webp?v=1777162849"},{"product_id":"abb-2csf204102r1630-fh204-a-63-0-03-4p-63a-rccb","title":"ABB 2CSF204102R1630 FH204 A-63\/0.03 4P 63A 30mA 6kA Type A Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB FH204 A-63\/0.03 (SKU: 2CSF204102R1630) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 63 A with a 30 mA sensitivity and a breaking capacity of 6 kA. Designed for DIN-Rail mounting, this Type A RCCB detects both sinusoidal and pulsating DC residual currents, making it suitable for protecting personnel and installations in industrial and commercial control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH204 A-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204102R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542892908\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN designation confirming dual compliance for RCCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Circuit-breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664-1:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against electric shock in industrial and commercial installations\u003c\/li\u003e\n\u003cli\u003eProtection of circuits with non-linear loads generating pulsating DC residual currents (Type A)\u003c\/li\u003e\n\u003cli\u003eMain or sub-distribution boards in industrial control panels\u003c\/li\u003e\n\u003cli\u003eBuilding automation and facility management electrical systems\u003c\/li\u003e\n\u003cli\u003eProtection of three-phase and neutral circuits in 4-wire distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995326235,"sku":"2CSF204102R1630","price":47.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204102r1630-fh204-a-63-0-03-current-circuit-breaker_c64fc51c-47eb-41b6-ae2a-4accd0ea5197.webp?v=1777162854"},{"product_id":"abb-2csf202201r3400-f202-a-s-40-0-3-2p-40a-rccb","title":"ABB 2CSF202201R3400 F202 A S-40\/0.3 2P 40A 300mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F202 A S-40\/0.3 (SKU: 2CSF202201R3400) is a 2-pole 40A residual current circuit breaker (RCCB) from the F200 series, designed to provide reliable earth fault protection in residential, commercial, and light industrial installations. Rated at 300mA sensitivity and mounted on standard DIN rail, this RCCB delivers fast disconnection upon detection of residual leakage current, safeguarding personnel and equipment. Compact at 35mm × 85mm × 69mm and weighing just 200g, the F202 A S-40\/0.3 is an efficient solution for modern distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 A S-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202201R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542784302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, ensuring compliance within the EU market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering humidity, temperature, and mechanical stress resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing end-of-life and recyclability requirements for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems performance for electric-drive vehicles and related protective devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification confirming compliance with North American safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU, free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for proper end-of-life disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units requiring earth leakage protection\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels in offices, retail, and hospitality environments\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels where personnel protection from earth faults is mandatory\u003c\/li\u003e\n\u003cli\u003eUpstream protection in circuits feeding sensitive equipment subject to leakage currents\u003c\/li\u003e\n\u003cli\u003eRetrofit and new-build installations requiring IEC 61008-compliant RCCB protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995391771,"sku":"2CSF202201R3400","price":83.16,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202201r3400-f202-a-s-40-0-3-circuit-breaker-rccb_b84a620e-9431-4b9d-a692-d5c1d75ece80.webp?v=1777162729"},{"product_id":"abb-2csf202201r3630-f202-a-s-63-0-3-2p-63a-rccb","title":"ABB 2CSF202201R3630 F202 A S-63\/0.3 2P 63A 300mA Type A Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 A S-63\/0.3 (SKU: 2CSF202201R3630) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 63 A with a 300 mA sensitivity and Type A fault detection. Designed for DIN-Rail installation, the F202 A S-63\/0.3 provides reliable protection against earth leakage currents in residential and light commercial installations, safeguarding both personnel and equipment from shock and fire hazards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 A S-63\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202201R3630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542784401\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A (AC + pulsating DC fault detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCB compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-82:\u003c\/strong\u003e European standard for ecodesign requirements applicable to electrical and electronic products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems performance for zero environmental impact\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from lead, mercury, cadmium and other restricted substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical regulation compliance confirming safe substance usage in product materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer units requiring earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eLight commercial installations with mixed AC and pulsating DC fault current risk (Type A)\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits supplying sockets, appliances, and portable equipment\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies on DIN-Rail where compact 35 mm width is essential\u003c\/li\u003e\n  \u003cli\u003eIndustrial auxiliary circuits requiring personnel protection per IEC 61008\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995457307,"sku":"2CSF202201R3630","price":95.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202201r3630-f202-a-s-63-0-3-current-circuit-breaker_90471100-bb77-4ce2-b3a8-612b03fd53bd.webp?v=1777162734"},{"product_id":"abb-2csf204201r3400-f204-a-s-40-0-3-4p-rccb","title":"ABB 2CSF204201R3400 F204 A S-40\/0.3 4P 40A 300mA DIN-Rail Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 A S-40\/0.3 residual current circuit breaker (RCCB), catalog number F204 A S-40\/0.3 and SKU 2CSF204201R3400, is a 4-pole, 40 A device with a 300 mA rated residual operating current, designed for DIN-rail installation in industrial and commercial control panels. Part of ABB's trusted F200 series, this RCCB provides reliable personnel and installation protection against earth leakage faults, combining compact dimensions of 70 mm × 85 mm × 69 mm with a lightweight 360 g form factor.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A S-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204201R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542784708\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle and recover electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems for electric-drive vehicles, confirming North American compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval for North American market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in industrial distribution boards and control panels\u003c\/li\u003e\n  \u003cli\u003ePersonnel protection against indirect contact in commercial and light-industrial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase + neutral circuits in building services and facility management systems\u003c\/li\u003e\n  \u003cli\u003eUpstream protection in sub-distribution panels where 300 mA sensitivity provides fire-hazard and selectivity-focused protection\u003c\/li\u003e\n  \u003cli\u003eIntegration with ABB F200 series accessories for modular, space-efficient switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995621147,"sku":"2CSF204201R3400","price":108.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204201r3400-f204-a-s-40-0-3-f204-a-s-40-0-3_6fef432f-24b2-4c3b-a3df-2f69137100b0.webp?v=1777393280"},{"product_id":"abb-2csf204201r3900-f204-a-s-100-0-3-4p-100a-rccb","title":"ABB 2CSF204201R3900 F204 A S-100\/0.3 4P 100A Residual Current Circuit Breaker (RCCB) DIN-Rail","description":"\u003cp\u003eThe ABB F204 A S-100\/0.3 (SKU: 2CSF204201R3900) is a 4-pole 100 A residual current circuit breaker (RCCB) from the ABB F200 series, designed for reliable earth-fault and shock-hazard protection in industrial and commercial installations. Rated at 300 mA trip sensitivity, this DIN-rail mounted RCCB provides personnel and equipment protection in distribution boards and control panels. Compliant with IEC 61008 and EN 61008, it meets the most demanding international standards for residual current devices.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A S-100\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204201R3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542919100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for residual current circuit-breakers (RCCB) for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard relating to generic methods for assessing the recyclability and recoverability of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical conversion systems and equipment, covering North American safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricting use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — compliant, ensuring safe use of chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant, supporting responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEarth-fault and personnel shock-hazard protection in industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eResidential and commercial final distribution panels requiring 4-pole RCCB protection\u003c\/li\u003e\u0026lt; li\u0026gt;Protection of motor circuits and three-phase loads against earth-leakage faults\u003cli\u003eControl panel assemblies where DIN-rail mounted residual current protection is mandated\u003c\/li\u003e\n\u003cli\u003eBuilding installations complying with IEC 61008 \/ EN 61008 earthing protection requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995850523,"sku":"2CSF204201R3900","price":211.66,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204201r3900-f204-a-s-100-0-3-breaker-rccb-din-rail_00602069-60f2-4caa-84c3-16722beef2e1.webp?v=1777162859"},{"product_id":"abb-2csf202401r1250-f202-a-25-0-03-ap-r-2p-25a-rccb","title":"ABB 2CSF202401R1250 F202 A-25\/0.03 AP-R 2P 25A 30mA Type A-APR Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 A-25\/0.03 AP-R (SKU: 2CSF202401R1250) is a 2-pole, 25A residual current circuit breaker (RCCB) from the F200 series, designed to provide reliable personal protection and fire prevention in industrial and commercial installations. Featuring a 30mA trip sensitivity and Type A-APR classification, the F202 A-25\/0.03 AP-R detects both sinusoidal and pulsating DC residual currents, making it suitable for modern electronic load environments. DIN-Rail mounted and compact at 35mm × 85mm × 69mm, this RCCB integrates seamlessly into standard control panels and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 A-25\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202401R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA-APR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, ensuring compliance with EU low-voltage directive requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering mechanical and climatic robustness across operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing specific end-of-life and sustainability performance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic household and office equipment to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification confirming compliance with North American safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive — free from lead, mercury, cadmium, and other restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e European chemicals regulation compliance, confirming safe substance use in manufacturing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonal protection against electric shock in residential, commercial, and light industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eFire prevention through detection of low-level earth leakage currents in final circuits\u003c\/li\u003e\n\u003cli\u003eProtection of circuits supplying modern electronic loads (variable speed drives, IT equipment) where pulsating DC fault currents may occur\u003c\/li\u003e\n\u003cli\u003eDIN-Rail installation in standard switchgear enclosures and control panels up to 25A\u003c\/li\u003e\n\u003cli\u003eBuilding installations requiring Type A sensitivity per IEC 61008 and CSA-certified equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995916059,"sku":"2CSF202401R1250","price":56.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202401r1250-f202-a-25-0-03-ap-r-current-circuit-breaker_44d7e7fb-e19d-4f31-ae9c-83d284ab6170.webp?v=1777162738"},{"product_id":"abb-2csf202401r1400-f202-a-40-0-03-ap-r-2p-40a-rccb","title":"ABB 2CSF202401R1400 F202 A-40\/0.03 AP-R 2P 40A 30mA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 A-40\/0.03 AP-R (SKU: 2CSF202401R1400) is a 2-pole 40 A residual current circuit breaker (RCCB) from ABB's trusted F200 series, designed to provide reliable earth-fault and personal-shock protection in residential and industrial control panels. With a 30 mA rated residual current and DIN-rail mounting, the F202 A-40\/0.03 AP-R delivers precision protection in a compact 35 mm × 85 mm × 69 mm footprint weighing only 200 g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 A-40\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202401R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs) for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008, confirming compliance for the EU market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering robustness under climatic and mechanical stress conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e Standard addressing end-of-life and sustainability criteria for electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be repaired, reused, or recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification confirming product safety compliance for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — confirms the product is free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical regulation compliance, confirming no substances of very high concern above threshold levels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Declaration of conformity with all applicable EU directives, mandatory for the European Economic Area\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring personal shock protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels with DIN-rail mounted protective devices\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection in offices, retail, and light industrial premises\u003c\/li\u003e\n  \u003cli\u003eEarth-leakage detection in automation and motor control centres\u003c\/li\u003e\n  \u003cli\u003eProtection of socket-outlet circuits per IEC wiring regulations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228995981595,"sku":"2CSF202401R1400","price":81.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202401r1400-f202-a-40-0-03-ap-r-f202-a-40-0-03-ap-r_3a327699-925c-40a8-8312-8cc376694446.webp?v=1777393275"},{"product_id":"abb-2csf202401r1630-f202-a-63-0-03-ap-r-rccb","title":"ABB 2CSF202401R1630 F202 A-63\/0.03 AP-R 2P 63A 30mA Type A-APR Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 A-63\/0.03 AP-R (SKU: 2CSF202401R1630) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 63 A with a 30 mA sensitivity, designed for Type A-APR protection. Engineered for DIN-rail installation, the F202 A-63\/0.03 AP-R delivers reliable earth-fault protection against both sinusoidal and pulsating DC fault currents in residential, commercial, and industrial control panel applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 A-63\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202401R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A-APR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008 for RCCBs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering durability under temperature, humidity, and mechanical stress\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e Specific requirements under the European ecodesign framework for networked standby and related functions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency and other resource aspects of energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification confirming compliance with North American safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from lead, mercury, cadmium and other restricted substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonal protection against electric shock in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eEarth-fault protection in commercial building automation and control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits supplying frequency converters, UPS systems, and other loads generating pulsating DC fault currents (Type A-APR)\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation panels requiring selective or time-delayed residual current protection\u003c\/li\u003e\n  \u003cli\u003eFinal circuits in industrial facilities where DIN-rail compact footprint is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996047131,"sku":"2CSF202401R1630","price":85.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202401r1630-f202-a-63-0-03-ap-r-current-circuit-breaker_3c7b65d5-6498-4f2a-a5a4-711c7e41af51.webp?v=1777162745"},{"product_id":"abb-2csf204401r1250-f204-a-25-0-03-ap-r-4p-25a-rccb","title":"ABB 2CSF204401R1250 F204 A-25\/0.03 AP-R 4P 25A 30mA Type A-APR Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 A-25\/0.03 AP-R (SKU: 2CSF204401R1250) is a 4-pole 25A residual current circuit breaker (RCCB) from the F200 series, offering 30mA sensitivity with Type A-APR fault-current detection for reliable personnel and installation protection. Designed for DIN-rail mounting in industrial and commercial control panels, the F204 A-25\/0.03 AP-R delivers robust residual current protection against both sinusoidal and pulsating DC fault currents, meeting the rigorous demands of modern electrical installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A-25\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204401R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A-APR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCB devices, ensuring compliance across EU markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical robustness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing sustainability and end-of-life provisions for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic household and office equipment to be repaired and upgraded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against indirect contact in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of circuits supplying variable speed drives, inverters, and equipment with DC residual current components (Type A-APR)\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical installations requiring 4-pole RCCB protection on three-phase systems\u003c\/li\u003e\n\u003cli\u003eAutomation and control panel assemblies demanding compact DIN-rail mounted residual current protection\u003c\/li\u003e\n\u003cli\u003eInstallations requiring compliance with IEC 61008 and EN 61008 in European and international markets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996309275,"sku":"2CSF204401R1250","price":73.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204401r1250-f204-a-25-0-03-ap-r-current-circuit-breaker_d2bf1d41-8447-4b9b-b5a1-173568c54e67.webp?v=1777162867"},{"product_id":"abb-2csf204401r1400-f204-a-40-0-03-ap-r-4p-40a-rccb","title":"ABB 2CSF204401R1400 F204 A-40\/0.03 AP-R 4P 40A 30mA Type A-APR Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 A-40\/0.03 AP-R (SKU: 2CSF204401R1400) is a 4-pole 40A residual current circuit breaker from the F200 series, designed to provide reliable earth-fault protection in industrial and commercial control panels. With a 30mA tripping sensitivity and Type A-APR characteristics, this RCCB detects both sinusoidal and pulsating DC residual currents, making it suitable for modern electrical installations with variable-frequency drives and electronic loads. DIN-rail mounted and IEC 61008 certified, it delivers dependable personnel and equipment protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A-40\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204401R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA-APR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard for generic end-of-life information for energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against earth faults in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection in circuits supplying variable-frequency drives and electronic equipment generating pulsating DC residual currents\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial building electrical installations requiring Type A-APR sensitivity\u003c\/li\u003e\n\u003cli\u003e4-wire (three-phase + neutral) distribution circuits requiring simultaneous pole switching\u003c\/li\u003e\n\u003cli\u003eApplications where enhanced selectivity and anti-pulsation (AP-R) performance is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996440347,"sku":"2CSF204401R1400","price":96.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204401r1400-f204-a-40-0-03-ap-r-current-circuit-breaker_3e37411e-059b-4469-89bf-89bc86266489.webp?v=1777162872"},{"product_id":"abb-2csf204401r1630-f204-a-63-0-03-ap-r-rccb","title":"ABB 2CSF204401R1630 F204 A-63\/0.03 AP-R 4P 63A 30mA Type A-APR Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 A-63\/0.03 AP-R (SKU: 2CSF204401R1630) is a 4-pole, 63A, 30mA Type A-APR residual current circuit breaker from the F200 series, engineered for reliable personnel and installation protection against earth fault currents in industrial and commercial power systems. Designed for DIN-rail mounting, this RCCB detects both sinusoidal AC and pulsating DC residual currents, making it well-suited for circuits supplying electronic equipment and variable speed drives.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A-63\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204401R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA-APR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542785606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for residual current circuit-breakers, ensuring compliance across EU markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering climatic and mechanical robustness\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing the end-of-life treatment of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be repaired, reused and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive — free of lead, mercury, cadmium, and other restricted substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the EU Waste Electrical and Electronic Equipment directive for responsible disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in industrial control panels and switchboards\u003c\/li\u003e\n  \u003cli\u003ePersonnel protection in commercial and light industrial installations\u003c\/li\u003e\n  \u003cli\u003eCircuits feeding variable speed drives, UPS systems, and other power electronics generating pulsating DC residual currents\u003c\/li\u003e\n  \u003cli\u003eFour-pole protection for three-phase and neutral systems\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC control panel distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996505883,"sku":"2CSF204401R1630","price":100.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204401r1630-f204-a-63-0-03-ap-r-current-circuit-breaker_cdb4950a-3d90-4eb9-8be3-0dc1b3de615c.webp?v=1777162876"},{"product_id":"abb-2csf204401r1900-f204-a-100-0-03-ap-r-4p-100a-rccb","title":"ABB 2CSF204401R1900 F204 A-100\/0.03 AP-R 4P 100A 30mA Type A AP-R Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 A-100\/0.03 AP-R (SKU: 2CSF204401R1900) is a 4-pole residual current circuit breaker (RCCB) rated at 100 A with a 30 mA residual current sensitivity, designed for reliable personnel and equipment protection against earth-fault currents in industrial and commercial installations. Part of the proven ABB F200 series, the F204 A-100\/0.03 AP-R mounts easily on standard DIN rail and is certified to IEC 61008, making it a trusted choice for control panels and distribution boards worldwide.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 A-100\/0.03 AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204401R1900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542919506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA (0.03 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A AP-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard for RCCBs, aligned with IEC 61008\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard covering robustness under climatic and mechanical stress\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-82:\u003c\/strong\u003e European standard addressing generic criteria for the design of environmentally conscious electrical and electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to be repaired, reused, and recycled for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — free from restricted hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePersonnel protection against indirect contact (earth faults) in industrial control panels\u003c\/li\u003e\n\u003cli\u003eEquipment protection in commercial and residential distribution boards\u003c\/li\u003e\n\u003cli\u003eFour-pole protection for three-phase + neutral circuits (TN, TT, and IT systems)\u003c\/li\u003e\n\u003cli\u003eType A AP-R sensitivity — suitable for circuits containing frequency converters, drives, and other loads generating pulsating DC residual currents\u003c\/li\u003e\n\u003cli\u003eBuilding automation, HVAC, and motor control centre (MCC) applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996636955,"sku":"2CSF204401R1900","price":188.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204401r1900-f204-a-100-0-03-ap-r-current-circuit-breaker_e25807c4-4763-4c23-8978-d421cd6a89d3.webp?v=1777162881"},{"product_id":"abb-2csf202568r1160-f202-b-16-0-03-2p-16a-rccb","title":"ABB 2CSF202568R1160 F202 B-16\/0.03 2P 16A 30mA DIN-Rail Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 B-16\/0.03 (SKU: 2CSF202568R1160) is a 2-pole 16 A residual current circuit breaker (RCCB) from the ABB F200 series, designed to provide reliable personal protection against electric shock and fire hazards caused by earth leakage currents. Featuring a 30 mA sensitivity threshold and DIN-rail mounting, the F202 B-16\/0.03 is engineered for use in residential, commercial, and light industrial distribution boards where dependable ground-fault detection is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 B-16\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202568R1160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Operating Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542341154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 1: General rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 2: Supplementary requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic household and office equipment to be repaired, reused, or recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Electrical Systems for Electric-Powered Industrial Trucks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996702491,"sku":"2CSF202568R1160","price":194.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202568r1160-f202-b-16-0-03-2csf202568r1160-f202-b-16-0-03_9d19d4b3-e0c7-4288-b649-4534214e2660.webp?v=1777393293"},{"product_id":"abb-2csf202568r1250-f202-b-25-0-03-2p-25a-rccb","title":"ABB 2CSF202568R1250 F202 B-25\/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F202 B-25\/0.03 (SKU: 2CSF202568R1250) is a 2-pole 25A residual current circuit breaker (RCCB) from the ABB F200 series, designed to provide reliable protection against earth leakage currents with a 30mA trip sensitivity. The F202 B-25\/0.03 mounts directly on standard DIN rail and delivers certified compliance with IEC 61008-1 and IEC 62423, making it a trusted choice for residential, commercial, and light industrial distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF202 B-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF202568R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542341253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 1: General rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit-breakers — Part 2: Supplementary requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and Type B residual current operated circuit-breakers with and without integral overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic equipment to be repaired, reused and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical systems for electric-drive vehicles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — EU compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228996768027,"sku":"2CSF202568R1250","price":194.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf202568r1250-f202-b-25-0-03-2csf202568r1250-f202-b-25-0-03_e7061bb8-6050-404a-a45c-141c41e0684f.webp?v=1777393286"},{"product_id":"abb-2csf204568r1250-f204-b-25-0-03-4p-25a-rccb","title":"ABB 2CSF204568R1250 F204 B-25\/0.03 4P 25A 30mA DIN-Rail Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 B-25\/0.03 (SKU: 2CSF204568R1250) is a 4-pole residual current circuit breaker (RCCB) rated at 25 A with a 30 mA sensitivity, designed for earth leakage and personal protection in industrial and commercial distribution boards. Part of ABB's trusted F200 series, the F204 B-25\/0.03 mounts on standard DIN rail and provides reliable disconnection against residual currents in accordance with IEC\/EN 61008-1 and IEC\/EN 62423 standards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 B-25\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204568R1250\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542341956\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Operating Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses — Part 1: General rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit-breakers — Part 2: Applicability of the general rules to RCCBs functionally dependent on line voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standards for electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle, reuse and recover electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Electrical Systems for Stationary and Movable Electric Vehicles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — compliant with EU RoHS 2 (2011\/65\/EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — proper disposal and recycling obligations met\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in industrial control panels and distribution boards\u003c\/li\u003e\n  \u003cli\u003ePersonal protection against electric shock in commercial buildings and facilities\u003c\/li\u003e\n  \u003cli\u003eThree-phase + neutral circuit protection in 4-wire systems\u003c\/li\u003e\n  \u003cli\u003eSupplementary protection in motor circuits, HVAC equipment, and process machinery\u003c\/li\u003e\n  \u003cli\u003eDIN rail installations in panel enclosures requiring compact, standards-compliant RCCDs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997423387,"sku":"2CSF204568R1250","price":252.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204568r1250-f204-b-25-0-03-2csf204568r1250-f204-b-25-0-03_6da101a5-e442-40af-989d-9de33e64b5a1.webp?v=1777393300"},{"product_id":"abb-2csf204568r1400-f204-b-40-0-03-4p-40a-rccb","title":"ABB 2CSF204568R1400 F204 B-40\/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F204 B-40\/0.03 residual current circuit breaker (RCCB), SKU 2CSF204568R1400, is a 4-pole, 40 A, 30 mA earth-leakage protection device from the F200 series designed for DIN-rail installation in residential, commercial, and light-industrial distribution boards. The F204 B-40\/0.03 provides reliable protection against electric shock caused by earth faults, combining compact dimensions of 70 mm × 85 mm × 69 mm with a robust 380 g construction built to IEC\/EN 61008-1 and IEC\/EN 62423 standards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 B-40\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204568R1400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542342052\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit breakers without integral overcurrent protection for household and similar uses — Part 1: General rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit breakers — Part 2: Functional requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and type B residual current operated circuit breakers with and without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — Part 2: Tests (climatic and mechanical durability)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555 \/ EN 45555-77:\u003c\/strong\u003e General methods for the assessment of the ability of electrical and electronic products to be repaired and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for safety for electrical energy storage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring 4-pole earth-fault protection\u003c\/li\u003e\n  \u003cli\u003eProtection of final circuits in industrial control panels and automation enclosures\u003c\/li\u003e\n  \u003cli\u003eSupplementary protection against electric shock in TN, TT, and IT earthing systems\u003c\/li\u003e\n  \u003cli\u003eProtection of outdoor equipment, swimming pools, and socket-outlet circuits per IEC 60364\u003c\/li\u003e\n  \u003cli\u003eDIN-rail installations requiring compact, lightweight RCCB solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997488923,"sku":"2CSF204568R1400","price":297.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204568r1400-f204-b-40-0-03-circuit-breaker-rccb_62766974-b733-44fc-88eb-a5738244b870.webp?v=1777162889"},{"product_id":"abb-2csf204568r1630-f204-b-63-0-03-4p-63a-rccb","title":"ABB 2CSF204568R1630 F204 B-63\/0.03 4P 63A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)","description":"\u003cp\u003eThe ABB F204 B-63\/0.03 (SKU: 2CSF204568R1630) is a 4-pole, 63 A residual current circuit breaker (RCCB) from the ABB F200 series, providing reliable earth-fault and personal-shock protection in industrial and commercial installations. Designed for DIN-rail mounting, the F204 B-63\/0.03 detects residual currents as low as 30 mA, delivering fast disconnection to protect personnel and equipment. Compact at 70 mm × 85 mm × 69 mm and weighing just 380 g, it fits neatly into standard distribution panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 B-63\/0.03\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204568R1630\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542342151\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 1: General rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 2: Specific requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and Type B residual current operated circuit-breakers with and without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical robustness verification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, upgraded, and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for Electrical Systems for Electric-Drive Vehicles (recognised listing)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Registration, Evaluation, Authorisation and Restriction of Chemicals regulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonnel protection against electric shock in commercial and industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eEarth-fault protection for 3-phase + neutral circuits in control panels and switchgear\u003c\/li\u003e\n  \u003cli\u003eSupplemental protection in TN and TT earthing systems\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and energy management installations requiring IEC 61008-compliant RCCBs\u003c\/li\u003e\n  \u003cli\u003eMachine builder and OEM panel assemblies requiring DIN-rail mounted residual current protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997554459,"sku":"2CSF204568R1630","price":343.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204568r1630-f204-b-63-0-03-circuit-breaker-rccb_378cd1ad-93c2-491f-a465-dd2c8ac19b01.webp?v=1777162900"},{"product_id":"abb-2csf204568r3400-f204-b-40-0-3-4p-40a-rccb","title":"ABB 2CSF204568R3400 F204 B-40\/0.3 4P 40A 300mA Type B Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 B-40\/0.3 residual current circuit breaker (RCCB), catalog number F204 B-40\/0.3 (SKU: 2CSF204568R3400), is a 4-pole, 40A, 300mA Type B device from the ABB F200 series designed to provide personnel and installation protection against earth leakage currents — including pulsating DC and smooth DC fault currents generated by modern frequency converters, EV chargers, and renewable energy systems. Its DIN-rail mount form factor fits standard industrial control panels, and its compact 70 × 85 × 69 mm footprint ensures efficient panel space utilisation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 B-40\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204568R3400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542342359\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRCD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-1 \/ EN 61008-1:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 1: General rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008-2 \/ EN 61008-2:\u003c\/strong\u003e Residual current operated circuit-breakers without integral overcurrent protection — Part 2: Particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 62423 \/ EN 62423:\u003c\/strong\u003e Type F and Type B residual current operated circuit-breakers with and without integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical systems including battery systems and equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of personnel and equipment in industrial control panels against earth leakage currents\u003c\/li\u003e\n  \u003cli\u003eElectric vehicle (EV) charging stations where Type B RCCB is mandated to detect smooth DC fault currents\u003c\/li\u003e\n  \u003cli\u003eFrequency converter (VFD) output circuits producing pulsating DC residual currents\u003c\/li\u003e\n  \u003cli\u003ePhotovoltaic (solar) installations and renewable energy systems\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial buildings requiring 4-pole earth leakage protection on three-phase distribution boards\u003c\/li\u003e\n  \u003cli\u003eMedical and laboratory equipment installations with stringent leakage current requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228997685531,"sku":"2CSF204568R3400","price":268.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204568r3400-f204-b-40-0-3-current-circuit-breaker_fa804d06-e4ef-4fb0-8c3c-bc9e6b66e974.webp?v=1777162908"},{"product_id":"abb-2csr255080r1064-ds201-c6-ac30-rcbo","title":"ABB 2CSR255080R1064 DS201 C6 AC30 1P+N 6A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO","description":"\u003cp\u003eThe \u003cstrong\u003eABB DS201 C6 AC30\u003c\/strong\u003e (SKU: 2CSR255080R1064) is a 1P+N residual current circuit breaker with overcurrent protection (RCBO), rated at 6 A with a 30 mA Type AC residual current sensitivity and a 10 kA breaking capacity. Designed for DIN-rail installation in domestic and light commercial distribution boards, the DS201 C6 AC30 provides simultaneous protection against overload, short-circuit, and earth leakage faults in a compact 35 mm wide, single-module form factor.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201 C6 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSR255080R1064\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542896319\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarth Leakage Circuit Breaker (RCBO)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009-1:\u003c\/strong\u003e Residual current operated circuit-breakers with integral overcurrent protection for household and similar use (RCBOs) — Part 1: General rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009-1:\u003c\/strong\u003e European adoption of IEC 61009-1 for RCBO general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009-2:\u003c\/strong\u003e RCBOs — Part 2: Specific requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009-2:\u003c\/strong\u003e European adoption of IEC 61009-2 for RCBO specific requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-1:\u003c\/strong\u003e Combined IEC\/EN designation for RCBO general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-2:\u003c\/strong\u003e Combined IEC\/EN designation for RCBO specific requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e Residual current operated circuit-breakers with integral overcurrent protection (general series reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Electrical accessories — Circuit-breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — Part 2: Tests\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the energy efficiency and other resource aspects of energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European designation for residual current operated circuit-breakers with integral overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination standard for low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the Eurasian Economic Union market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999651611,"sku":"2CSR255080R1064","price":41.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csr255080r1064-ds201-c6-ac30-circuit-breaker-rcbo_ad40f95b-7969-4ac0-b2b5-a6dd065c2e4f.webp?v=1777162913"},{"product_id":"abb-2csr255080r1104-ds201-c10-ac30-rcbo","title":"ABB 2CSR255080R1104 DS201 C10 AC30 1P+N 10A 30mA Type AC 10kA Earth Leakage Circuit Breaker RCBO","description":"\u003cp\u003eThe ABB DS201 C10 AC30 (SKU: 2CSR255080R1104) is a 1P+N residual current circuit breaker with overcurrent protection (RCBO), combining earth leakage protection at 30 mA sensitivity with a 10 A rated current and a 10 kA breaking capacity in a single compact DIN-rail device. Designed for Type AC residual current detection, the DS201 C10 AC30 provides reliable personnel and installation protection against earth faults and short-circuit currents in residential, commercial, and light industrial control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201 C10 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSR255080R1104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC (Type C trip curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542049418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-1:\u003c\/strong\u003e International standard for RCBOs — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009-1:\u003c\/strong\u003e European harmonised standard for RCBOs — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-2:\u003c\/strong\u003e International standard for RCBOs — supplementary requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009-2:\u003c\/strong\u003e European harmonised standard for RCBOs — supplementary requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-1:\u003c\/strong\u003e Combined IEC\/EN residual current circuit breaker with overcurrent protection standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-2:\u003c\/strong\u003e Combined IEC\/EN supplementary RCBO standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e Core RCBO standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European RCBO standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breaker standard for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European standard for residual current operated circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for the EAEU market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards requiring combined overcurrent and earth fault protection\u003c\/li\u003e\n\u003cli\u003eCommercial electrical installations needing single-module 1P+N RCBO protection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels with Type AC sinusoidal earth leakage current detection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for socket outlets, lighting circuits, and appliance circuits\u003c\/li\u003e\n\u003cli\u003eRetrofit replacement for separate MCB and RCCB combinations in space-constrained enclosures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228999946523,"sku":"2CSR255080R1104","price":41.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csr255080r1104-ds201-c10-ac30-circuit-breaker-rcbo_2316643d-b378-46e2-b41e-72a295c8c943.webp?v=1777162917"},{"product_id":"abb-2csr255080r1164-ds201-c16-ac30-rcbo-16a","title":"ABB 2CSR255080R1164 DS201 C16 AC30 1P+N 16A 30mA Type AC 6kA Earth Leakage Circuit Breaker RCBO","description":"\u003cp\u003eThe \u003cstrong\u003eABB DS201 C16 AC30\u003c\/strong\u003e (SKU: 2CSR255080R1164) is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) rated at 16A, 230V, with a 30mA Type AC residual current sensitivity and a 6kA breaking capacity. Combining overcurrent and earth leakage protection in a single 2-module DIN rail device, the DS201 C16 AC30 delivers reliable personnel and installation protection in residential and light commercial control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201 C16 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSR255080R1164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542049210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P+N (2 pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurve C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN60715 35mm (clip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.200 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-1 \/ EN 61009-1:\u003c\/strong\u003e Primary standard for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-2-1 \/ EN 61009-2-1:\u003c\/strong\u003e Particular rules for RCBOs applicable to household and similar applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-2 \/ EN 61009-2:\u003c\/strong\u003e Supplementary requirements for RCBOs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-1:\u003c\/strong\u003e Combined IEC\/EN harmonised standard for RCBOs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-2:\u003c\/strong\u003e Combined IEC\/EN harmonised supplementary standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC61009 \/ EN61009:\u003c\/strong\u003e General RCBO compliance family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit-breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-6:\u003c\/strong\u003e Environmental testing — vibration (sinusoidal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU Low Voltage and RoHS Directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555-75:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse and recycle electrical\/electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark for Russia\/CIS markets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of socket outlet circuits requiring 30mA sensitivity per IEC 61009-1\u003c\/li\u003e\n\u003cli\u003eLight commercial and office electrical installations\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and outdoor circuit protection where earth leakage risk is elevated\u003c\/li\u003e\n\u003cli\u003eRetrofit or new installation in 35mm DIN rail panels requiring combined RCD and MCB functionality in a space-saving 2-module format\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229000306971,"sku":"2CSR255080R1164","price":38.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csr255080r1164-ds201-c16-ac30-circuit-breaker-rcbo_d0e0ff15-80d5-4e2c-b846-0c3e7e6e81e4.webp?v=1777162922"},{"product_id":"abb-2csr255080r1204-ds201-c20-ac30-rcbo","title":"ABB 2CSR255080R1204 DS201 C20 AC30 1P+N 20A 10kA Type AC 30mA Earth Leakage Circuit Breaker RCBO","description":"\u003cp\u003eThe ABB DS201 C20 AC30 (SKU: 2CSR255080R1204) is a 1P+N Residual Current Circuit Breaker with Overcurrent Protection (RCBO) rated at 20 A with a 30 mA residual current sensitivity and a 10 kA breaking capacity. Designed for Type AC earth leakage detection, the DS201 C20 AC30 provides simultaneous protection against both overload\/short-circuit currents and earth leakage faults in a compact DIN-rail mount package — ideal for residential and light commercial distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201 C20 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSR255080R1204\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542049111\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarth Leakage Circuit Breaker (RCBO)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC (Type C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009-1:\u003c\/strong\u003e Residual current operated circuit breakers with integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009-1:\u003c\/strong\u003e European harmonised standard for RCBOs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009-2:\u003c\/strong\u003e Supplementary requirements for RCBOs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009-2:\u003c\/strong\u003e European harmonised supplementary requirements for RCBOs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-1:\u003c\/strong\u003e Combined IEC\/EN conformity for RCBO fundamental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-2:\u003c\/strong\u003e Combined IEC\/EN conformity for RCBO supplementary requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61009:\u003c\/strong\u003e General RCBO product family compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — climatic and mechanical robustness\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse, and recycle networked products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European harmonised general RCBO product standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity mark — approved for Russia, Kazakhstan, and Belarus markets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eLight commercial and office electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of socket-outlet circuits requiring earth leakage detection\u003c\/li\u003e\n  \u003cli\u003eControl panel branch circuit protection where combined overcurrent and RCD protection is required in a single module\u003c\/li\u003e\n  \u003cli\u003eRetrofit replacement in 1P+N DIN-rail distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229000601883,"sku":"2CSR255080R1204","price":38.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csr255080r1204-ds201-c20-ac30-circuit-breaker-rcbo_87e24de7-0563-4f1f-a896-affa8eb67493.webp?v=1777162927"},{"product_id":"abb-2csr255080r1404-ds201-c40-ac30-rcbo","title":"ABB 2CSR255080R1404 DS201 C40 AC30 1P+N 40A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO","description":"\u003cp\u003eThe ABB DS201 C40 AC30 (SKU: 2CSR255080R1404) is a 1P+N earth leakage circuit breaker with overcurrent protection (RCBO) rated at 40A with a 30mA residual current sensitivity and Type AC detection, designed for reliable protection of residential and commercial electrical installations. Delivering a 10kA breaking capacity on a compact DIN-rail mount profile of 35mm × 85mm × 69mm, this DS201 C40 AC30 combines overcurrent and earth fault protection in a single 1P+N device, simplifying panel design and reducing wiring complexity for engineers and installers alike.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201 C40 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSR255080R1404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542048817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarth Leakage Circuit Breaker (RCBO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC (Curve C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-1:\u003c\/strong\u003e Residual current operated circuit-breakers with integral overcurrent protection for household use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009-1:\u003c\/strong\u003e European adoption of IEC 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61009-2:\u003c\/strong\u003e Supplementary requirements for RCBOs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009-2:\u003c\/strong\u003e European adoption of IEC 61009-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-1:\u003c\/strong\u003e Combined IEC\/EN designation for RCBO performance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61009-2:\u003c\/strong\u003e Combined IEC\/EN designation for supplementary RCBO requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit-breakers for overcurrent protection in household installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing procedures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be reused, repaired, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61009:\u003c\/strong\u003e European standard for RCBOs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAC:\u003c\/strong\u003e Eurasian Conformity marking for Russia\/CIS markets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units requiring combined overcurrent and earth fault protection\u003c\/li\u003e\n\u003cli\u003eCommercial and light industrial control panels with space-optimised 1P+N layouts\u003c\/li\u003e\n\u003cli\u003eProtection of socket outlet circuits, lighting circuits, and sensitive loads against earth faults\u003c\/li\u003e\n\u003cli\u003eRetrofit or upgrade of existing MCB installations to include residual current protection\u003c\/li\u003e\n\u003cli\u003eApplications requiring Type AC sensitivity (sinusoidal residual currents) per IEC 61009-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229001519387,"sku":"2CSR255080R1404","price":42.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csr255080r1404-ds201-c40-ac30-circuit-breaker-rcbo_1803dfa9-64a9-4458-8458-d91d4d06bfd0.webp?v=1777162941"}],"url":"https:\/\/stoklink.com\/collections\/rccb.oembed?page=3","provider":"Stoklink","version":"1.0","type":"link"}