{"title":"Power Factor Correction","description":"\u003cp\u003ePower factor correction capacitors, controllers and reactive power compensation components.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-blrcs125a150b40","title":"Schneider Electric BLRCS125A150B40 EasyLogic 12.5\/15 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS125A150B40 is an EasyLogic power factor correction capacitor rated 12.5 kvar at 400 V, 50 Hz (15 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS125A150B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12.5 kvar and 400 V, the BLRCS125A150B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080565575963,"sku":"BLRCS125A150B40","price":51.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs125a150b40-easylogic-pfc-capacitor.jpg?v=1790934594"},{"product_id":"schneider-electric-blrch400a480b52","title":"Schneider Electric BLRCH400A480B52 VarPlus Can HDuty 40\/48 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH400A480B52 is a VarPlus Can HDuty power factor correction capacitor rated 40 kvar at 525 V, 50 Hz (48 kvar at 60 Hz). Its heavy-duty dielectric tolerates network harmonic content up to 20 % and a continuous overcurrent capacity of 1.8 x In, so it keeps correcting power factor on busbars that also feed variable-speed drives, rectifiers and other harmonic-generating loads without overheating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH400A480B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic (VarPlus Can HDuty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 40 kvar and 525 V, the BLRCH400A480B52 is sized for incomers or filter branches with documented harmonic distortion up to 20% - its 1.8 x In continuous overcurrent capacity and 250 x In inrush rating are built in for duty where variable-speed drives or rectifiers already share the busbar. Pick a smaller HDuty step in the same 525 V family when correcting a lighter non-linear load, or a larger one as the reactive power demand grows. On network segments that stay under 10% harmonic content, the standard-duty EasyLogic range covers the same kvar steps at a lower continuous overcurrent rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080565641499,"sku":"BLRCH400A480B52","price":159.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch400a480b52-varplus-can-hduty-pfc-capacitor.jpg?v=1790934594"},{"product_id":"schneider-electric-blrcs125a150b44","title":"Schneider Electric BLRCS125A150B44 EasyLogic 12.5\/15 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS125A150B44 is an EasyLogic power factor correction capacitor rated 12.5 kvar at 440 V, 50 Hz (15 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS125A150B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12.5 kvar and 440 V, the BLRCS125A150B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080566591771,"sku":"BLRCS125A150B44","price":54.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs125a150b44-easylogic-pfc-capacitor.jpg?v=1790934606"},{"product_id":"schneider-electric-blrch417a500b40","title":"Schneider Electric BLRCH417A500B40 VarPlus Can HDuty 41.7\/50 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH417A500B40 is a VarPlus Can HDuty power factor correction capacitor rated 41.7 kvar at 400 V, 50 Hz (50 kvar at 60 Hz). Its heavy-duty dielectric tolerates network harmonic content up to 20 % and a continuous overcurrent capacity of 1.8 x In, so it keeps correcting power factor on busbars that also feed variable-speed drives, rectifiers and other harmonic-generating loads without overheating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH417A500B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic (VarPlus Can HDuty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.7 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 41.7 kvar and 400 V, the BLRCH417A500B40 is sized for incomers or filter branches with documented harmonic distortion up to 20% - its 1.8 x In continuous overcurrent capacity and 250 x In inrush rating are built in for duty where variable-speed drives or rectifiers already share the busbar. Pick a smaller HDuty step in the same 400 V family when correcting a lighter non-linear load, or a larger one as the reactive power demand grows. On network segments that stay under 10% harmonic content, the standard-duty EasyLogic range covers the same kvar steps at a lower continuous overcurrent rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080566624539,"sku":"BLRCH417A500B40","price":156.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch417a500b40-varplus-can-hduty-pfc-capacitor.jpg?v=1790934606"},{"product_id":"schneider-electric-blrcs125a150b48","title":"Schneider Electric BLRCS125A150B48 EasyLogic 12.5\/15 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS125A150B48 is an EasyLogic power factor correction capacitor rated 12.5 kvar at 480 V, 50 Hz (15 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS125A150B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12.5 kvar and 480 V, the BLRCS125A150B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080568033563,"sku":"BLRCS125A150B48","price":63.53,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs125a150b48-easylogic-pfc-capacitor.jpg?v=1790934618"},{"product_id":"schneider-electric-blrch500a000b40","title":"Schneider Electric BLRCH500A000B40 VarPlus Can HDuty 50 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH500A000B40 is a VarPlus Can HDuty power factor correction capacitor rated 50 kvar at 400 V, 50 Hz. Its heavy-duty dielectric tolerates network harmonic content up to 20 % and a continuous overcurrent capacity of 1.8 x In, so it keeps correcting power factor on busbars that also feed variable-speed drives, rectifiers and other harmonic-generating loads without overheating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH500A000B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic (VarPlus Can HDuty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 50 kvar and 400 V, the BLRCH500A000B40 is sized for incomers or filter branches with documented harmonic distortion up to 20% - its 1.8 x In continuous overcurrent capacity and 250 x In inrush rating are built in for duty where variable-speed drives or rectifiers already share the busbar. Pick a smaller HDuty step in the same 400 V family when correcting a lighter non-linear load, or a larger one as the reactive power demand grows. On network segments that stay under 10% harmonic content, the standard-duty EasyLogic range covers the same kvar steps at a lower continuous overcurrent rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080568099099,"sku":"BLRCH500A000B40","price":168.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch500a000b40-varplus-can-hduty-pfc-capacitor.jpg?v=1790934620"},{"product_id":"schneider-electric-blrcs125a150b52","title":"Schneider Electric BLRCS125A150B52 EasyLogic 12.5\/15 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS125A150B52 is an EasyLogic power factor correction capacitor rated 12.5 kvar at 525 V, 50 Hz (15 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS125A150B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 12.5 kvar and 525 V, the BLRCS125A150B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080569377051,"sku":"BLRCS125A150B52","price":71.61,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs125a150b52-easylogic-pfc-capacitor.jpg?v=1790934630"},{"product_id":"schneider-electric-blrch500a000b44","title":"Schneider Electric BLRCH500A000B44 VarPlus Can HDuty 50 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH500A000B44 is a VarPlus Can HDuty power factor correction capacitor rated 50 kvar at 440 V, 50 Hz. Its heavy-duty dielectric tolerates network harmonic content up to 20 % and a continuous overcurrent capacity of 1.8 x In, so it keeps correcting power factor on busbars that also feed variable-speed drives, rectifiers and other harmonic-generating loads without overheating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH500A000B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic (VarPlus Can HDuty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 50 kvar and 440 V, the BLRCH500A000B44 is sized for incomers or filter branches with documented harmonic distortion up to 20% - its 1.8 x In continuous overcurrent capacity and 250 x In inrush rating are built in for duty where variable-speed drives or rectifiers already share the busbar. Pick a smaller HDuty step in the same 440 V family when correcting a lighter non-linear load, or a larger one as the reactive power demand grows. On network segments that stay under 10% harmonic content, the standard-duty EasyLogic range covers the same kvar steps at a lower continuous overcurrent rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080569442587,"sku":"BLRCH500A000B44","price":160.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch500a000b44-varplus-can-hduty-pfc-capacitor.jpg?v=1790934632"},{"product_id":"schneider-electric-blrcs143a172b44","title":"Schneider Electric BLRCS143A172B44 EasyLogic 14.3\/17.2 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS143A172B44 is an EasyLogic power factor correction capacitor rated 14.3 kvar at 440 V, 50 Hz (17.2 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS143A172B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.3 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.2 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 14.3 kvar and 440 V, the BLRCS143A172B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080571015451,"sku":"BLRCS143A172B44","price":57.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs143a172b44-easylogic-pfc-capacitor.jpg?v=1790934643"},{"product_id":"schneider-electric-blrch571a000b44","title":"Schneider Electric BLRCH571A000B44 VarPlus Can HDuty 57.1 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH571A000B44 is a VarPlus Can HDuty power factor correction capacitor rated 57.1 kvar at 440 V, 50 Hz. Its heavy-duty dielectric tolerates network harmonic content up to 20 % and a continuous overcurrent capacity of 1.8 x In, so it keeps correcting power factor on busbars that also feed variable-speed drives, rectifiers and other harmonic-generating loads without overheating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH571A000B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic (VarPlus Can HDuty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.1 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStud terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 321 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 57.1 kvar and 440 V, the BLRCH571A000B44 is sized for incomers or filter branches with documented harmonic distortion up to 20% - its 1.8 x In continuous overcurrent capacity and 250 x In inrush rating are built in for duty where variable-speed drives or rectifiers already share the busbar. Pick a smaller HDuty step in the same 440 V family when correcting a lighter non-linear load, or a larger one as the reactive power demand grows. On network segments that stay under 10% harmonic content, the standard-duty EasyLogic range covers the same kvar steps at a lower continuous overcurrent rating.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080571080987,"sku":"BLRCH571A000B44","price":178.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch571a000b44-varplus-can-hduty-pfc-capacitor.jpg?v=1790934644"},{"product_id":"schneider-electric-blrcs150a180b40","title":"Schneider Electric BLRCS150A180B40 EasyLogic 15\/18 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS150A180B40 is an EasyLogic power factor correction capacitor rated 15 kvar at 400 V, 50 Hz (18 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS150A180B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15 kvar and 400 V, the BLRCS150A180B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080572555547,"sku":"BLRCS150A180B40","price":59.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs150a180b40-easylogic-pfc-capacitor.jpg?v=1790934656"},{"product_id":"schneider-electric-blrcs010a012b40","title":"Schneider Electric BLRCS010A012B40 EasyLogic 1\/1.2 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS010A012B40 is an EasyLogic power factor correction capacitor rated 1 kvar at 400 V, 50 Hz (1.2 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS010A012B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1 kvar and 400 V, the BLRCS010A012B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080572588315,"sku":"BLRCS010A012B40","price":26.46,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs010a012b40-easylogic-pfc-capacitor.jpg?v=1790934656"},{"product_id":"schneider-electric-blrcs150a180b44","title":"Schneider Electric BLRCS150A180B44 EasyLogic 15\/18 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS150A180B44 is an EasyLogic power factor correction capacitor rated 15 kvar at 440 V, 50 Hz (18 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS150A180B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15 kvar and 440 V, the BLRCS150A180B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080574521627,"sku":"BLRCS150A180B44","price":65.29,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs150a180b44-easylogic-pfc-capacitor.jpg?v=1790934668"},{"product_id":"schneider-electric-blrcs017a020b40","title":"Schneider Electric BLRCS017A020B40 EasyLogic 1.7\/2 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS017A020B40 is an EasyLogic power factor correction capacitor rated 1.7 kvar at 400 V, 50 Hz (2 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS017A020B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1.7 kvar and 400 V, the BLRCS017A020B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080574488859,"sku":"BLRCS017A020B40","price":27.56,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs017a020b40-easylogic-pfc-capacitor.jpg?v=1790934668"},{"product_id":"schneider-electric-blrcs025a030b40","title":"Schneider Electric BLRCS025A030B40 EasyLogic 2.5\/3 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS025A030B40 is an EasyLogic power factor correction capacitor rated 2.5 kvar at 400 V, 50 Hz (3 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS025A030B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 2.5 kvar and 400 V, the BLRCS025A030B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080575471899,"sku":"BLRCS025A030B40","price":31.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs025a030b40-easylogic-pfc-capacitor.jpg?v=1790934680"},{"product_id":"schneider-electric-blrcs154a185b52","title":"Schneider Electric BLRCS154A185B52 EasyLogic 15.4\/18.5 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS154A185B52 is an EasyLogic power factor correction capacitor rated 15.4 kvar at 525 V, 50 Hz (18.5 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS154A185B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.4 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15.4 kvar and 525 V, the BLRCS154A185B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080575504667,"sku":"BLRCS154A185B52","price":79.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs154a185b52-easylogic-pfc-capacitor.jpg?v=1790934680"},{"product_id":"schneider-electric-blrcs030a036b44","title":"Schneider Electric BLRCS030A036B44 EasyLogic 3\/3.6 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS030A036B44 is an EasyLogic power factor correction capacitor rated 3 kvar at 440 V, 50 Hz (3.6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS030A036B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 3 kvar and 440 V, the BLRCS030A036B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080577634587,"sku":"BLRCS030A036B44","price":36.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs030a036b44-easylogic-pfc-capacitor.jpg?v=1790934691"},{"product_id":"schneider-electric-blrcs155a186b48","title":"Schneider Electric BLRCS155A186B48 EasyLogic 15.5\/18.6 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS155A186B48 is an EasyLogic power factor correction capacitor rated 15.5 kvar at 480 V, 50 Hz (18.6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS155A186B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15.5 kvar and 480 V, the BLRCS155A186B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080577700123,"sku":"BLRCS155A186B48","price":73.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs155a186b48-easylogic-pfc-capacitor.jpg?v=1790934693"},{"product_id":"schneider-electric-blrcs050a060b40","title":"Schneider Electric BLRCS050A060B40 EasyLogic 5\/6 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS050A060B40 is an EasyLogic power factor correction capacitor rated 5 kvar at 400 V, 50 Hz (6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS050A060B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 5 kvar and 400 V, the BLRCS050A060B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080578617627,"sku":"BLRCS050A060B40","price":36.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs050a060b40-easylogic-pfc-capacitor.jpg?v=1790934703"},{"product_id":"schneider-electric-blrcs170a204b48","title":"Schneider Electric BLRCS170A204B48 EasyLogic 17\/20.4 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS170A204B48 is an EasyLogic power factor correction capacitor rated 17 kvar at 480 V, 50 Hz (20.4 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS170A204B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 17 kvar and 480 V, the BLRCS170A204B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080578650395,"sku":"BLRCS170A204B48","price":78.54,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs170a204b48-easylogic-pfc-capacitor.jpg?v=1790934705"},{"product_id":"schneider-electric-blrcs050a060b44","title":"Schneider Electric BLRCS050A060B44 EasyLogic 5\/6 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS050A060B44 is an EasyLogic power factor correction capacitor rated 5 kvar at 440 V, 50 Hz (6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS050A060B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 5 kvar and 440 V, the BLRCS050A060B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080579895579,"sku":"BLRCS050A060B44","price":39.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs050a060b44-easylogic-pfc-capacitor.jpg?v=1790934716"},{"product_id":"schneider-electric-blrcs182a218b44","title":"Schneider Electric BLRCS182A218B44 EasyLogic 18.2\/21.8 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS182A218B44 is an EasyLogic power factor correction capacitor rated 18.2 kvar at 440 V, 50 Hz (21.8 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS182A218B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.2 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.8 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18.2 kvar and 440 V, the BLRCS182A218B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080579961115,"sku":"BLRCS182A218B44","price":73.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs182a218b44-easylogic-pfc-capacitor.jpg?v=1790934717"},{"product_id":"schneider-electric-blrcs050a060b52","title":"Schneider Electric BLRCS050A060B52 EasyLogic 5\/6 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS050A060B52 is an EasyLogic power factor correction capacitor rated 5 kvar at 525 V, 50 Hz (6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS050A060B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 5 kvar and 525 V, the BLRCS050A060B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080581075227,"sku":"BLRCS050A060B52","price":49.67,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs050a060b52-easylogic-pfc-capacitor.jpg?v=1790934730"},{"product_id":"schneider-electric-blrcs186a223b48","title":"Schneider Electric BLRCS186A223B48 EasyLogic 18.6\/22.3 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS186A223B48 is an EasyLogic power factor correction capacitor rated 18.6 kvar at 480 V, 50 Hz (22.3 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS186A223B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.3 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 18.6 kvar and 480 V, the BLRCS186A223B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080581435675,"sku":"BLRCS186A223B48","price":86.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs186a223b48-easylogic-pfc-capacitor.jpg?v=1790934731"},{"product_id":"schneider-electric-blrcs067a080b48","title":"Schneider Electric BLRCS067A080B48 EasyLogic 6.7\/8 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS067A080B48 is an EasyLogic power factor correction capacitor rated 6.7 kvar at 480 V, 50 Hz (8 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS067A080B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 6.7 kvar and 480 V, the BLRCS067A080B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080582517019,"sku":"BLRCS067A080B48","price":43.89,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs067a080b48-easylogic-pfc-capacitor.jpg?v=1790934742"},{"product_id":"schneider-electric-blrcs200a240b40","title":"Schneider Electric BLRCS200A240B40 EasyLogic 20\/24 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS200A240B40 is an EasyLogic power factor correction capacitor rated 20 kvar at 400 V, 50 Hz (24 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS200A240B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 20 kvar and 400 V, the BLRCS200A240B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080582910235,"sku":"BLRCS200A240B40","price":65.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs200a240b40-easylogic-pfc-capacitor.jpg?v=1790934744"},{"product_id":"schneider-electric-blrcs075a090b40","title":"Schneider Electric BLRCS075A090B40 EasyLogic 7.5\/9 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS075A090B40 is an EasyLogic power factor correction capacitor rated 7.5 kvar at 400 V, 50 Hz (9 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS075A090B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 7.5 kvar and 400 V, the BLRCS075A090B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080583827739,"sku":"BLRCS075A090B40","price":41.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs075a090b40-easylogic-pfc-capacitor.jpg?v=1790934754"},{"product_id":"schneider-electric-blrcs200a240b44","title":"Schneider Electric BLRCS200A240B44 EasyLogic 20\/24 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS200A240B44 is an EasyLogic power factor correction capacitor rated 20 kvar at 440 V, 50 Hz (24 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS200A240B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 20 kvar and 440 V, the BLRCS200A240B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080583893275,"sku":"BLRCS200A240B44","price":75.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs200a240b44-easylogic-pfc-capacitor.jpg?v=1790934756"},{"product_id":"schneider-electric-blrcs075a090b44","title":"Schneider Electric BLRCS075A090B44 EasyLogic 7.5\/9 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS075A090B44 is an EasyLogic power factor correction capacitor rated 7.5 kvar at 440 V, 50 Hz (9 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS075A090B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 7.5 kvar and 440 V, the BLRCS075A090B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080584450331,"sku":"BLRCS075A090B44","price":47.03,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs075a090b44-easylogic-pfc-capacitor.jpg?v=1790934767"},{"product_id":"schneider-electric-blrcs200a240b52","title":"Schneider Electric BLRCS200A240B52 EasyLogic 20\/24 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS200A240B52 is an EasyLogic power factor correction capacitor rated 20 kvar at 525 V, 50 Hz (24 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS200A240B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 20 kvar and 525 V, the BLRCS200A240B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080584548635,"sku":"BLRCS200A240B52","price":91.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs200a240b52-easylogic-pfc-capacitor.jpg?v=1790934768"},{"product_id":"schneider-electric-blrcs088a106b48","title":"Schneider Electric BLRCS088A106B48 EasyLogic 8.8\/10.6 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS088A106B48 is an EasyLogic power factor correction capacitor rated 8.8 kvar at 480 V, 50 Hz (10.6 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS088A106B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 8.8 kvar and 480 V, the BLRCS088A106B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080584974619,"sku":"BLRCS088A106B48","price":53.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs088a106b48-easylogic-pfc-capacitor.jpg?v=1790934779"},{"product_id":"schneider-electric-blrcs250a300b40","title":"Schneider Electric BLRCS250A300B40 EasyLogic 25\/30 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS250A300B40 is an EasyLogic power factor correction capacitor rated 25 kvar at 400 V, 50 Hz (30 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS250A300B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 kvar and 400 V, the BLRCS250A300B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080585138459,"sku":"BLRCS250A300B40","price":75.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs250a300b40-easylogic-pfc-capacitor.jpg?v=1790934781"},{"product_id":"schneider-electric-blrcs100a120b44","title":"Schneider Electric BLRCS100A120B44 EasyLogic 10\/12 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS100A120B44 is an EasyLogic power factor correction capacitor rated 10 kvar at 440 V, 50 Hz (12 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS100A120B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Faston terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm x 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10 kvar and 440 V, the BLRCS100A120B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080586154267,"sku":"BLRCS100A120B44","price":49.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs100a120b44-easylogic-pfc-capacitor.jpg?v=1790934791"},{"product_id":"schneider-electric-blrcs250a300b44","title":"Schneider Electric BLRCS250A300B44 EasyLogic 25\/30 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS250A300B44 is an EasyLogic power factor correction capacitor rated 25 kvar at 440 V, 50 Hz (30 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS250A300B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 kvar and 440 V, the BLRCS250A300B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080586514715,"sku":"BLRCS250A300B44","price":78.87,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs250a300b44-easylogic-pfc-capacitor.jpg?v=1790934794"},{"product_id":"schneider-electric-blrcs104a125b40","title":"Schneider Electric BLRCS104A125B40 EasyLogic 10.4\/12.5 kvar 400 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS104A125B40 is an EasyLogic power factor correction capacitor rated 10.4 kvar at 400 V, 50 Hz (12.5 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS104A125B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 400 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380…415 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10.4 kvar and 400 V, the BLRCS104A125B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587432219,"sku":"BLRCS104A125B40","price":44.93,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs104a125b40-easylogic-pfc-capacitor.jpg?v=1790934803"},{"product_id":"schneider-electric-blrcs250a300b52","title":"Schneider Electric BLRCS250A300B52 EasyLogic 25\/30 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS250A300B52 is an EasyLogic power factor correction capacitor rated 25 kvar at 525 V, 50 Hz (30 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS250A300B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25 kvar and 525 V, the BLRCS250A300B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587497755,"sku":"BLRCS250A300B52","price":99.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs250a300b52-easylogic-pfc-capacitor.jpg?v=1790934806"},{"product_id":"schneider-electric-blrch250a300b44-hduty-25kvar-440v","title":"Schneider Electric BLRCH250A300B44 VarPlus Can HDuty 25 kvar 440 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH250A300B44 is a VarPlus Can HDuty power factor correction capacitor rated 25 kvar at 440 V, 50 Hz (30 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 116 mm diameter, IP20 enclosure weighing 2.5 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH250A300B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar at 440 V, 50 Hz \/ 30 kvar at 440 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH250A300B44 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 440 V the unit delivers 25 kvar on a 50 Hz network or 30 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 116 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587858203,"sku":"BLRCH250A300B44","price":101.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch250a300b44-varplus-can-hduty-capacitor.jpg?v=1790934809"},{"product_id":"schneider-electric-blrch150a180b40-hduty-15kvar-400v","title":"Schneider Electric BLRCH150A180B40 VarPlus Can HDuty 15 kvar 400 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH150A180B40 is a VarPlus Can HDuty power factor correction capacitor rated 15 kvar at 400 V, 50 Hz (18 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 90 mm diameter, IP20 enclosure weighing 1.6 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH150A180B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar at 400 V, 50 Hz \/ 18 kvar at 400 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 380 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5 kvar at 50 Hz \/ 16.2 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 415 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.1 kvar at 50 Hz \/ 19.4 kvar at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH150A180B40 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 400 V the unit delivers 15 kvar on a 50 Hz network or 18 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 90 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587890971,"sku":"BLRCH150A180B40","price":69.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch150a180b40-varplus-can-hduty-capacitor.jpg?v=1790934810"},{"product_id":"schneider-electric-blrcs104a125b48","title":"Schneider Electric BLRCS104A125B48 EasyLogic 10.4\/12.5 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS104A125B48 is an EasyLogic power factor correction capacitor rated 10.4 kvar at 480 V, 50 Hz (12.5 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS104A125B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10.4 kvar and 480 V, the BLRCS104A125B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587923739,"sku":"BLRCS104A125B48","price":57.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs104a125b48-easylogic-pfc-capacitor.jpg?v=1790934816"},{"product_id":"schneider-electric-blrcs258a310b48","title":"Schneider Electric BLRCS258A310B48 EasyLogic 25.8\/31 kvar 480 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS258A310B48 is an EasyLogic power factor correction capacitor rated 25.8 kvar at 480 V, 50 Hz (31 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS258A310B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.8 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 480 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 25.8 kvar and 480 V, the BLRCS258A310B48 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 480 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080587956507,"sku":"BLRCS258A310B48","price":95.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs258a310b48-easylogic-pfc-capacitor.jpg?v=1790934818"},{"product_id":"schneider-electric-blrch250a300b52-hduty-25kvar-525v","title":"Schneider Electric BLRCH250A300B52 VarPlus Can HDuty 25 kvar 525 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH250A300B52 is a VarPlus Can HDuty power factor correction capacitor rated 25 kvar at 525 V, 50 Hz (30 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 116 mm diameter, IP20 enclosure weighing 2.5 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH250A300B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar at 525 V, 50 Hz \/ 30 kvar at 525 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH250A300B52 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 525 V the unit delivers 25 kvar on a 50 Hz network or 30 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 116 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080588349723,"sku":"BLRCH250A300B52","price":126.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch250a300b52-varplus-can-hduty-capacitor.jpg?v=1790934822"},{"product_id":"schneider-electric-blrch150a180b44-hduty-15kvar-440v","title":"Schneider Electric BLRCH150A180B44 VarPlus Can HDuty 15 kvar 440 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH150A180B44 is a VarPlus Can HDuty power factor correction capacitor rated 15 kvar at 440 V, 50 Hz (18 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 90 mm diameter, IP20 enclosure weighing 1.6 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH150A180B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar at 440 V, 50 Hz \/ 18 kvar at 440 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH150A180B44 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 440 V the unit delivers 15 kvar on a 50 Hz network or 18 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 90 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080588382491,"sku":"BLRCH150A180B44","price":75.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch150a180b44-varplus-can-hduty-capacitor.jpg?v=1790934823"},{"product_id":"schneider-electric-blrcs106a127b52","title":"Schneider Electric BLRCS106A127B52 EasyLogic 10.6\/12.7 kvar 525 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS106A127B52 is an EasyLogic power factor correction capacitor rated 10.6 kvar at 525 V, 50 Hz (12.7 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS106A127B52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 525 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.7 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10.6 kvar and 525 V, the BLRCS106A127B52 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 525 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080588808475,"sku":"BLRCS106A127B52","price":66.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs106a127b52-easylogic-pfc-capacitor.jpg?v=1790934828"},{"product_id":"schneider-electric-blrcs285a342b44","title":"Schneider Electric BLRCS285A342B44 EasyLogic 28.5\/34.2 kvar 440 V Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCS285A342B44 is an EasyLogic power factor correction capacitor rated 28.5 kvar at 440 V, 50 Hz (34.2 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCS285A342B44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.5 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power at 440 V, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.2 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses (dielectric \/ total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 W\/kvar dielectric, \u0026lt; 0.5 W\/kVAr total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 % to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum switching operations per year\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 308 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 28.5 kvar and 440 V, the BLRCS285A342B44 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 440 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080589562139,"sku":"BLRCS285A342B44","price":79.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrcs285a342b44-easylogic-pfc-capacitor.jpg?v=1790934830"},{"product_id":"schneider-electric-blrch250a300b69-hduty-25kvar-690v","title":"Schneider Electric BLRCH250A300B69 VarPlus Can HDuty 25 kvar 690 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH250A300B69 is a VarPlus Can HDuty power factor correction capacitor rated 25 kvar at 690 V, 50 Hz (30 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 136 mm diameter, IP20 enclosure weighing 3.2 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH250A300B69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kvar at 690 V, 50 Hz \/ 30 kvar at 690 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH250A300B69 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 690 V the unit delivers 25 kvar on a 50 Hz network or 30 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 136 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080589955355,"sku":"BLRCH250A300B69","price":183.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch250a300b69-varplus-can-hduty-capacitor.jpg?v=1790934836"},{"product_id":"schneider-electric-blrch150a180b57-hduty-15kvar-575v","title":"Schneider Electric BLRCH150A180B57 VarPlus Can HDuty 15 kvar 575 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH150A180B57 is a VarPlus Can HDuty power factor correction capacitor rated 15 kvar at 575 V, 50 Hz (18 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 136 mm diameter, IP20 enclosure weighing 3.2 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH150A180B57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar at 575 V, 50 Hz \/ 18 kvar at 575 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e575 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH150A180B57 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 575 V the unit delivers 15 kvar on a 50 Hz network or 18 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 136 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080589988123,"sku":"BLRCH150A180B57","price":141.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch150a180b57-varplus-can-hduty-capacitor.jpg?v=1790934835"},{"product_id":"schneider-electric-blrch150a180b69-hduty-15kvar-690v","title":"Schneider Electric BLRCH150A180B69 VarPlus Can HDuty 15 kvar 690 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH150A180B69 is a VarPlus Can HDuty power factor correction capacitor rated 15 kvar at 690 V, 50 Hz (18 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 116 mm diameter, IP20 enclosure weighing 2.5 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH150A180B69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kvar at 690 V, 50 Hz \/ 18 kvar at 690 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH150A180B69 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 690 V the unit delivers 15 kvar on a 50 Hz network or 18 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 116 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080590938395,"sku":"BLRCH150A180B69","price":157.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch150a180b69-varplus-can-hduty-capacitor.jpg?v=1790934847"},{"product_id":"schneider-electric-blrch258a310b48-hduty-25-8kvar-480v","title":"Schneider Electric BLRCH258A310B48 VarPlus Can HDuty 25.8 kvar 480 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH258A310B48 is a VarPlus Can HDuty power factor correction capacitor rated 25.8 kvar at 480 V, 50 Hz (31 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 116 mm diameter, IP20 enclosure weighing 2.5 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH258A310B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.8 kvar at 480 V, 50 Hz \/ 31 kvar at 480 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH258A310B48 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 480 V the unit delivers 25.8 kvar on a 50 Hz network or 31 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 116 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080591298843,"sku":"BLRCH258A310B48","price":121.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch258a310b48-varplus-can-hduty-capacitor.jpg?v=1790934849"},{"product_id":"schneider-electric-blrch155a186b48-hduty-15-5kvar-480v","title":"Schneider Electric BLRCH155A186B48 VarPlus Can HDuty 15.5 kvar 480 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH155A186B48 is a VarPlus Can HDuty power factor correction capacitor rated 15.5 kvar at 480 V, 50 Hz (18.6 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 90 mm diameter, IP20 enclosure weighing 1.6 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH155A186B48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.5 kvar at 480 V, 50 Hz \/ 18.6 kvar at 480 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH155A186B48 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 480 V the unit delivers 15.5 kvar on a 50 Hz network or 18.6 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 90 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080592544027,"sku":"BLRCH155A186B48","price":91.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch155a186b48-varplus-can-hduty-capacitor.jpg?v=1790934859"},{"product_id":"schneider-electric-blrch276a331b69-hduty-27-6kvar-690v","title":"Schneider Electric BLRCH276A331B69 VarPlus Can HDuty 27.6 kvar 690 V 50 Hz Power Factor Correction Capacitor","description":"\u003cp\u003eThe Schneider Electric BLRCH276A331B69 is a VarPlus Can HDuty power factor correction capacitor rated 27.6 kvar at 690 V, 50 Hz (33.1 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 136 mm diameter, IP20 enclosure weighing 3.2 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLRCH276A331B69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerLogic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVarPlus Can HDuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated reactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6 kvar at 690 V, 50 Hz \/ 33.1 kvar at 690 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork harmonic content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum permissible voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 x Un (8 hours over 24 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous overcurrent \/ inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 x In continuous \/ 250 x In inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric \u0026lt; 0.2 W\/kvar, total \u0026lt; 0.5 W\/kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage test (terminal to terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.15 x Un AC for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClampTite terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpright\/horizontal, indoor installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (diameter x height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…+55 °C (temperature class D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 2000 m, ≤ 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60831-1\u003c\/li\u003e\n\u003cli\u003eIEC 60831-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eHDuty (heavy duty) construction gives the BLRCH276A331B69 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 690 V the unit delivers 27.6 kvar on a 50 Hz network or 33.1 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 136 mm x 242 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080592576795,"sku":"BLRCH276A331B69","price":191.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-blrch276a331b69-varplus-can-hduty-capacitor.jpg?v=1790934862"}],"url":"https:\/\/stoklink.com\/collections\/power-factor-correction.oembed?page=6","provider":"Stoklink","version":"1.0","type":"link"}