{"title":"Power Contactors (AC-3)","description":"\u003cp\u003ePower contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/abb-af-contactors\"\u003eABB AF Contactors\u003c\/a\u003e – 3 and 4 pole AF series with wide-range AC\/DC coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/schneider-tesys-deca\"\u003eSchneider TeSys Deca Contactors\u003c\/a\u003e – the largest series here, from 9 A to 200 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/schneider-tesys-giga\"\u003eSchneider TeSys Giga Contactors\u003c\/a\u003e – high-current frames from 115 A to 800 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/schneider-tesys-k\"\u003eSchneider TeSys K Contactors\u003c\/a\u003e – compact contactors for 6 A to 16 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/schneider-easy-tesys\"\u003eSchneider Easy TeSys Contactors\u003c\/a\u003e – general-purpose contactors from 6 A to 630 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/siemens-3rt2-contactors\"\u003eSiemens SIRIUS 3RT2 Contactors\u003c\/a\u003e and \u003ca href=\"\/collections\/siemens-3rt1-contactors\"\u003eSiemens SIRIUS 3RT1 Contactors\u003c\/a\u003e – SIRIUS frames from small to very large.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.\u003c\/li\u003e\n\u003cli\u003ePole count: 3P for motors, 4P where the neutral is switched.\u003c\/li\u003e\n\u003cli\u003eCoil voltage and type, AC or DC, against the control supply.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact needs and whether add-on blocks fit the frame.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does AC-3 mean on a contactor?\u003c\/h3\u003e\u003cp\u003eAC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.\u003c\/p\u003e\u003ch3\u003eCan I replace a contactor with another brand?\u003c\/h3\u003e\u003cp\u003eCheck rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.\u003c\/p\u003e\u003ch3\u003eDo you ship contactors outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"abb-gjl1213001r0101-bc6-30-10-01-mini-contactor","title":"ABB GJL1213001R0101 BC6-30-10-01 Mini Power Contactor AC Switching 3NO 20A 4kW 24V DC Coil 3-Pole","description":"\u003cp\u003eThe ABB BC6-30-10-01 (SKU: GJL1213001R0101) is a compact mini power contactor designed for AC switching applications, delivering reliable 3-pole (3NO) switching at a rated current of 20 A and motor power of 4 kW. Featuring a 24V DC coil and screw terminal connections, the BC6-30-10-01 is engineered for space-efficient installation in control panels via DIN rail or direct wall mounting, making it an ideal solution for industrial automation and motor control tasks.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC6-30-10-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1213001R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3NO (3 Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614052880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Household and similar electrical appliances — safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus \/ cUL:\u003c\/strong\u003e Listed by Underwriters Laboratories for US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certificate for Chinese market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor control and AC switching in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eControl panel assemblies requiring compact, space-saving contactors\u003c\/li\u003e\n\u003cli\u003eConveyor systems, pumps, fans, and light-duty motor starters\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control applications\u003c\/li\u003e\n\u003cli\u003eOEM machinery requiring reliable 24V DC coil switching devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229116928283,"sku":"GJL1213001R0101","price":15.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1213001r0101-bc6-30-10-01-dc-coil-3-pole_a4596e4a-e48a-42a3-b92d-faa873ed1afa.webp?v=1777163058"},{"product_id":"abb-gjl1311001r8100-b7-30-10-80-mini-contactor","title":"ABB GJL1311001R8100 B7-30-10-80 3-Pole 20A 220-240V AC 5.5kW Mini Power Contactor AC Switching","description":"\u003cp\u003eThe ABB B7-30-10-80 (SKU: GJL1311001R8100) is a compact 3-pole mini power contactor designed for AC switching applications, rated at 20 A (AC-1) and 5.5 kW (AC-3) with a 220–240 V AC coil voltage. The B7-30-10-80 features screw terminal connections and supports both DIN rail and wall mounting, making it an ideal solution for motor control, automation panels, and industrial switching tasks where space efficiency is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB7-30-10-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1311001R8100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614150197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO, 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Listed to UL standards for use in North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union CE marking directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e Meets UK Conformity Assessed marking requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters for low-voltage applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for robustness and reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor switching and control in industrial automation panels\u003c\/li\u003e\n\u003cli\u003eHVAC equipment and compressor control up to 5.5 kW\u003c\/li\u003e\n\u003cli\u003eConveyor systems and light machinery in manufacturing environments\u003c\/li\u003e\n\u003cli\u003ePump and fan control in building services installations\u003c\/li\u003e\n\u003cli\u003eOEM machine builders requiring compact DIN-rail-mounted switching devices\u003c\/li\u003e\n\u003cli\u003eControl panel integration where space is at a premium\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117059355,"sku":"GJL1311001R8100","price":14.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1311001r8100-b7-30-10-80-contactor-ac-switching_05b169cf-317a-44bd-ba39-410ab05d2b35.webp?v=1777163068"},{"product_id":"abb-gjl1311001r8010-b7-30-01-80-20a-3p-contactor","title":"ABB GJL1311001R8010 B7-30-01-80 3-Pole 20A 5.5kW 220-240V AC Mini Power Contactor AC Switching Screw Terminals","description":"\u003cp\u003eThe ABB GJL1311001R8010 B7-30-01-80 is a 3-pole mini power contactor designed for AC switching applications, rated at 20A and 5.5kW with a 220–240V AC coil voltage. The B7-30-01-80 features screw terminal connections, a compact footprint of 52.5mm × 57.5mm × 46.7mm, and supports both DIN rail and wall mounting — making it an ideal solution for control panels, motor control circuits, and industrial automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB7-30-01-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1311001R8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614152047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO, 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories certification for North American safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for Canadian market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters performance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety requirements for household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Det Norske Veritas Germanischer Lloyd marine and offshore certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR Certificate:\u003c\/strong\u003e Lloyd's Register type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC Certificate:\u003c\/strong\u003e Korean Certification mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on chemicals (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor control circuits in industrial automation and manufacturing environments\u003c\/li\u003e\n\u003cli\u003eControl panel assembly for HVAC, pumping, and conveyor systems\u003c\/li\u003e\n\u003cli\u003eMarine and offshore electrical installations (DNV GL, LR, RMRS certified)\u003c\/li\u003e\n\u003cli\u003eBuilding automation and light industrial machinery switching\u003c\/li\u003e\n\u003cli\u003eOEM equipment requiring compact, reliable AC switching contactors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117255963,"sku":"GJL1311001R8010","price":14.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1311001r8010-b7-30-01-80-switching-screw-terminals_87badb29-248f-48db-a53d-52d3ed259b58.webp?v=1777163063"},{"product_id":"abb-gjl1211001r8100-b6-30-10-80-mini-contactor","title":"ABB GJL1211001R8100 B6-30-10-80 3-Pole 20A AC-1 220-240V AC Screw Terminal Mini Power Contactor AC Switching","description":"\u003cp\u003eThe ABB B6-30-10-80 (SKU: GJL1211001R8100) is a compact 3-pole mini power contactor designed for AC switching applications in industrial control panels and automation systems. Rated at 20 A (AC-1) and 4 kW (AC-3), the B6-30-10-80 operates on a 220–240 V AC coil voltage and features screw terminals for reliable, vibration-resistant wiring. Its compact 52.5 × 57.5 × 46.7 mm footprint supports both DIN rail and wall mounting, making it ideal for space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB6-30-10-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1211001R8100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614150647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Contact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO + 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — General rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters for low-voltage applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformity with European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSwitching of resistive and inductive loads in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eMotor switching up to 4 kW (AC-3) in light-duty motor starter circuits\u003c\/li\u003e\n\u003cli\u003eIntegration into compact control panels where DIN rail or wall-mount space is limited\u003c\/li\u003e\n\u003cli\u003eHVAC and building services control circuits operating on 230 V AC\u003c\/li\u003e\n\u003cli\u003eMachine tool and packaging machinery control applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117321499,"sku":"GJL1211001R8100","price":12.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1211001r8100-b6-30-10-80-contactor-ac-switching_2fc013fd-be5c-4904-8fe9-94b5327465a7.webp?v=1777163049"},{"product_id":"abb-gjl1313001r0101-bc7-30-10-01-mini-contactor","title":"ABB GJL1313001R0101 BC7-30-10-01 Mini Power Contactor 3NO 20A 5.5kW 24V DC Coil AC Switching Screw Terminals","description":"\u003cp\u003eThe ABB BC7-30-10-01 (SKU: GJL1313001R0101) is a compact mini power contactor designed for AC switching applications, rated at 20 A and 5.5 kW with a 24V DC coil and 3 NO (normally open) contacts. Part of ABB's BC7 series, the BC7-30-10-01 supports both DIN rail and wall mounting, making it highly versatile for space-constrained control panels and industrial automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC7-30-10-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1313001R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614150159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO (Normally Open), 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets European health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — certified for the UK market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters — performance and safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for electrical components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals (EC 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117387035,"sku":"GJL1313001R0101","price":17.58,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1313001r0101-bc7-30-10-01-switching-screw-terminals_07d27730-55db-4a30-b244-2e43e505d782.webp?v=1777163079"},{"product_id":"abb-gjl1213001r0011-bc6-30-01-01-mini-contactor-20a","title":"ABB GJL1213001R0011 BC6-30-01-01 Mini Power Contactor AC Switching 3NO 20A 4kW 24V DC Coil Screw Terminals","description":"\u003cp\u003eThe ABB BC6-30-01-01 (SKU: GJL1213001R0011) is a mini power contactor designed for AC switching applications, offering 3 normally open (NO) contacts, a 20 A rated current, and 4 kW motor power output. Operated by a 24 V DC coil with screw terminals, the BC6-30-01-01 is engineered for compact control panel installations and supports both DIN rail and wall mounting — making it an ideal choice for industrial automation and motor control circuits.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC6-30-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1213001R0011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC6\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614052828\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO + 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European equivalent of IEC 60947-1 for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC and EN standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters standard compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety requirements for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for market access in China\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Underwriters Laboratories certification for Canada and USA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e UL certification for Canadian market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking for EU market access\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eCompact control panels requiring space-efficient 3-pole contactors\u003c\/li\u003e\n  \u003cli\u003eHVAC equipment and building automation control circuits\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and light machinery motor starters\u003c\/li\u003e\n  \u003cli\u003ePLC-driven automation lines with 24 V DC control voltage\u003c\/li\u003e\n  \u003cli\u003eGeneral AC load switching in commercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117583643,"sku":"GJL1213001R0011","price":15.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1213001r0011-bc6-30-01-01-coil-screw-terminals_0fde9003-a210-43d3-931f-55d1b62f09f8.webp?v=1777163054"},{"product_id":"abb-gjl1211001r8010-b6-30-01-80-mini-power-contactor","title":"ABB GJL1211001R8010 B6-30-01-80 3-Pole 20A AC-1 4kW 220-240V AC Mini Power Contactor AC Switching Screw Terminals","description":"\u003cp\u003eThe ABB B6-30-01-80 (SKU: GJL1211001R8010) is a 3-pole mini power contactor designed for AC switching applications, rated at 20A (AC-1) and 4kW (AC-3) with a 220–240V AC coil voltage. The B6-30-01-80 features a compact 52.5 × 57.5 × 46.7mm footprint, 3NO contact configuration, screw terminals, and supports both DIN rail and wall mounting — making it ideal for industrial control panels and motor switching circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB6-30-01-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1211001R8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO + 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614153099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for Canadian and North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard — general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Safety of household and similar electrical appliances — particular requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — standard test methods for reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU recycling requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor switching and control in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eControl panel assembly for machinery and process equipment\u003c\/li\u003e\n\u003cli\u003eHVAC equipment switching and fan motor control\u003c\/li\u003e\n\u003cli\u003eLighting contactor applications in commercial and industrial installations\u003c\/li\u003e\n\u003cli\u003eGeneral AC load switching in 220–240V single- and three-phase circuits\u003c\/li\u003e\n\u003cli\u003eBuilding automation and pump control systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229117681947,"sku":"GJL1211001R8010","price":12.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1211001r8010-b6-30-01-80-switching-screw-terminals_8a11ade1-61a4-4104-933c-015adff1d6cb.webp?v=1777163044"},{"product_id":"abb-gjl1313001r0011-bc7-30-01-01-mini-contactor","title":"ABB GJL1313001R0011 BC7-30-01-01 Mini Power Contactor 3NO 20A AC-1 5.5kW AC-3 24V DC Coil Screw Terminals","description":"\u003cp\u003eThe ABB BC7-30-01-01 (SKU: GJL1313001R0011) is a compact mini power contactor designed for AC switching applications, featuring a 3NO contact configuration and a 24V DC control coil. Rated at 20A AC-1 and 5.5kW AC-3, the BC7-30-01-01 delivers reliable performance in space-constrained control panels with its slim 52.5 × 57.5 × 46.7mm footprint and rail or wall mounting flexibility.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC7-30-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGJL1313001R0011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBC7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614152603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO + 0 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRail or Wall Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 57.5 mm × 46.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union product safety and electromagnetic compatibility directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Certificate:\u003c\/strong\u003e Underwriters Laboratories certification for North American safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60335-2:\u003c\/strong\u003e Household and similar electrical appliances safety standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard for durability and reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Det Norske Veritas GL marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR Certificate:\u003c\/strong\u003e Lloyd's Register type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMRS Certificate:\u003c\/strong\u003e Russian Maritime Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC Certificate:\u003c\/strong\u003e Korean Certification mark for South Korea market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor switching and control in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eLighting and heating load control in building automation\u003c\/li\u003e\n\u003cli\u003eCompact control panel installations requiring DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eMarine and offshore electrical systems (DNV GL, LR, RMRS approved)\u003c\/li\u003e\n\u003cli\u003eHVAC and commercial building management systems\u003c\/li\u003e\n\u003cli\u003eOEM machine builder applications requiring a small-footprint 3-pole contactor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229118140699,"sku":"GJL1313001R0011","price":17.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-gjl1313001r0011-bc7-30-01-01-coil-screw-terminals_f146807a-af5d-4ca7-aa17-e2654acd08d8.webp?v=1777163073"},{"product_id":"abb-1sbl101001r2610-as09-30-10-26-power-contactor","title":"ABB 1SBL101001R2610 AS09-30-10-26 3-Pole 690V AC 230V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AS09-30-10-26 (SKU: 1SBL101001R2610) is a 3-pole power contactor designed for AC switching applications, rated up to 690V AC with a 230V 50\/60Hz control coil. Part of ABB's AS09 contactor series, this compact unit — measuring just 78 × 80 × 48 mm and weighing 0.22 kg — delivers reliable switching performance for motor control, industrial automation, and control panel applications. The AS09-30-10-26 meets an extensive range of international standards including IEC, UL, CE, and UKCA, making it suitable for global deployments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS09-30-10-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL101001R2610\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS09\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC \/ 220V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 × 80 × 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523032262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical safety and EMC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for electrical products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories safety certification (UL 508)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL508:\u003c\/strong\u003e Standard for Industrial Control Equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Industrial Control Equipment standard for Canada\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Electromechanical control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Combined IEC and EN standard for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1 \/ EN 60947-4-1:\u003c\/strong\u003e Combined IEC and EN standard for contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control and starting circuits in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eControl panel switching for machinery and manufacturing equipment\u003c\/li\u003e\n  \u003cli\u003eHVAC systems requiring reliable AC switching up to 690V\u003c\/li\u003e\n  \u003cli\u003ePump and compressor control in building services and utilities\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose load switching in commercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229118697755,"sku":"1SBL101001R2610","price":13.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl101001r2610-as09-30-10-26-contactor-ac-switching_c9490acc-b7b7-4653-bdaf-2a1a8b6ec959.webp?v=1777156722"},{"product_id":"abb-1sbl101001r2601-as09-30-01-26-power-contactor","title":"ABB 1SBL101001R2601 AS09-30-01-26 3-Pole 9A 690V AC 230V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AS09-30-01-26 power contactor (SKU: 1SBL101001R2601) is a 3-pole AC switching contactor rated for up to 690 V AC and 220 V DC, designed for demanding industrial motor control and load-switching applications. Featuring a 230 V 50\/60 Hz control coil, this compact AS09 series contactor measures just 78 × 80 × 48 mm and weighs 220 g, making it ideal for space-constrained control panel assemblies. The AS09-30-01-26 carries a comprehensive suite of international certifications including CE, UL, CCC, and IEC 60947-4-1, ensuring global compliance across industrial automation projects.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS09-30-01-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL101001R2601\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS09\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523033269\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC \/ 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 × 80 × 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU low-voltage and EMC directive requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e International standard for contactors and motor starters — AC electromechanical contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ IEC 60947-5:\u003c\/strong\u003e Supplementary IEC standards for contactors and control devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-1:\u003c\/strong\u003e Low-voltage switchgear general requirements (IEC designation variant)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing standard compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment standard for North America\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Canadian Standards Association industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association general certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — substance compliance confirmed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229118828827,"sku":"1SBL101001R2601","price":13.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl101001r2601-as09-30-01-26-contactor-ac-switching_24968024-b32e-44a7-88b4-4f30db1492cb.webp?v=1777156715"},{"product_id":"abb-1sbl111001r2601-as12-30-01-26-power-contactor","title":"ABB 1SBL111001R2601 AS12-30-01-26 3-Pole 690V AC 230V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AS12-30-01-26 (SKU: 1SBL111001R2601) is a 3-pole power contactor engineered for AC switching applications in industrial control panels and automation systems. Rated up to 690 V AC or 220 V DC, this compact contactor from ABB's AS12 series measures just 78 × 80 × 48 mm and weighs 0.22 kg, making it ideal for space-constrained panel installations. The AS12-30-01-26 coil is rated at 230 V 50\/60 Hz, ensuring compatibility with standard European and global supply voltages.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS12-30-01-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL111001R2601\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS12\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523035263\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower contactor, AC switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC \/ 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 × 80 × 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU product safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — required for Great Britain market access post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory for products sold in the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary certification affirming product quality standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — North American safety certification for electrical components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for Industrial Control Equipment — covers industrial controllers and contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Canadian Standards Association — industrial control equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association general compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements — electromechanical devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1 \/ 60947-4-1:\u003c\/strong\u003e Combined compliance with both IEC and EN harmonised switchgear standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — covers mechanical and climatic robustness\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — limits use of specific hazardous materials in electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — responsible end-of-life disposal compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial machinery and production lines\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies requiring compact, DIN-rail-compatible switching devices\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC system contactors\u003c\/li\u003e\n  \u003cli\u003ePump and conveyor control in process industries\u003c\/li\u003e\n  \u003cli\u003eGeneral AC load switching in industrial automation and control systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229119451419,"sku":"1SBL111001R2601","price":14.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl111001r2601-as12-30-01-26-contactor-ac-switching_0793a44c-11b1-4db2-a34d-9c5fc3379962.webp?v=1777156729"},{"product_id":"abb-1sbl121001r2610-as16-30-10-26-power-contactor","title":"ABB 1SBL121001R2610 AS16-30-10-26 3-Pole 690V AC 230V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AS16-30-10-26 power contactor (SKU: 1SBL121001R2610) is a 3-pole AC switching contactor rated up to 690V AC, designed for industrial motor control and load switching applications in control panels and automation systems. Featuring a 230V 50\/60Hz coil, the AS16-30-10-26 delivers reliable switching performance in a compact 78 × 80 × 48 mm footprint weighing just 0.22 kg, making it ideal for space-constrained panel builds.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS16-30-10-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL121001R2610\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC \/ 220V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 × 80 × 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523036260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliance with Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for voluntary product quality assurance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories safety certification for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 N°14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e German Association for Electrical, Electronic \u0026amp; Information Technologies certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Electromechanical control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1\/60947-4-1 \u0026amp; EN 60947-1\/60947-4-1:\u003c\/strong\u003e Combined compliance with IEC and EN switchgear standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European standard for degrees of protection provided by enclosures\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor starting and control in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eLoad switching in control panels and MCC (Motor Control Centres)\u003c\/li\u003e\n  \u003cli\u003eHeating, ventilation, and air conditioning (HVAC) control\u003c\/li\u003e\n  \u003cli\u003ePump and compressor control circuits\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose AC switching in building and process automation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229120139547,"sku":"1SBL121001R2610","price":16.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl121001r2610-as16-30-10-26-contactor-ac-switching_34dbef4a-47a5-4106-9756-16639b23067d.webp?v=1777156742"},{"product_id":"abb-1sbl121001r2601-as16-30-01-26-3p-contactor","title":"ABB 1SBL121001R2601 AS16-30-01-26 3-Pole 230V 690V AC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AS16-30-01-26 power contactor (SKU: 1SBL121001R2601) is a 3-pole AC switching contactor rated for 690 V AC operation with a 230 V 50\/60 Hz coil, designed for reliable motor and load control in industrial automation and control panel applications. Compact at just 78 × 80 × 48 mm and weighing only 0.22 kg, the AS16-30-01-26 delivers robust switching performance in a space-saving DIN-rail-mountable form factor. Part of ABB's AS16 series, this contactor meets a comprehensive set of international standards including IEC 60947-4-1 and UL 508, making it suitable for global installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS16-30-01-26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL121001R2601\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 × 80 × 48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523037267\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — additional Chinese quality mark\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for Industrial Control Equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for Canadian market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Industrial Control Equipment standard for Canada\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1:\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4-1:\u003c\/strong\u003e European harmonised standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements (series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Contactors and motor starters (series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU RoHS directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229120237851,"sku":"1SBL121001R2601","price":16.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl121001r2601-as16-30-01-26-contactor-ac-switching_7dc8eb68-0b6a-472c-bd20-97c9340cacaa.webp?v=1777156735"},{"product_id":"abb-1sbl157001r1301-af12-30-01-13-power-contactor","title":"ABB 1SBL157001R1301 AF12-30-01-13 3-Pole 12A 690V Coil 100-250V AC\/DC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12-30-01-13 power contactor (SKU: 1SBL157001R1301) is a 3-pole AC switching contactor rated at 28 A and 690 V, delivering reliable motor switching at up to 5.5 kW. Part of ABB's AF series, the AF12-30-01-13 features a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), making it highly versatile for global industrial automation and control panel applications. Its compact 45 mm × 86 mm × 77 mm footprint and 0.27 kg weight simplify panel design and installation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12-30-01-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL157001R1301\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110434\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliance for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for safety of household and similar electrical appliances (HVACR)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL file reference for UL 60335-2-40 compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for HVACR electrical appliances safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA file reference for C22.2 No. 60335-2-40 compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA general series for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA general series for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e International\/European standard — general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e International\/European standard — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC and EN compliance for general low-voltage switchgear rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC and EN compliance for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e IEC standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock resistance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB scheme certification for international market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — certified for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — certified for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary assessment standard for material and energy recovery\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation — no substances of very high concern above threshold\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — registered for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229121483035,"sku":"1SBL157001R1301","price":17.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl157001r1301-af12-30-01-13-contactor-ac-switching_b80abb89-d3ff-4d46-a653-55a8f7be722b.webp?v=1777156806"},{"product_id":"abb-1sbl137001r1310-af09-30-10-13-3p-contactor","title":"ABB 1SBL137001R1310 AF09-30-10-13 3-Pole 9A 690V AC\/DC Coil 100-250V Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF09-30-10-13 power contactor (SKU: 1SBL137001R1310) is a compact 3-pole AC switching contactor rated for 9A at up to 690V, delivering 4kW motor switching capability with a wide-range 100–250V AC\/DC coil. Part of ABB's AF Series, this industrial contactor is engineered for reliable control panel and motor control center applications, offering universal coil technology that accepts both AC and DC control voltages without requiring separate variants.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF09-30-10-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL137001R1310\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110038\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for voluntary product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas certification for marine and offshore use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listing for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme international safety certificate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters (UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL safety standard for HVACR equipment with A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for HVACR equipment with A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e Canadian standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse, and recycle energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Specific methods for assessment of energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control in HVAC systems, pumps, fans, and compressors up to 4 kW\u003c\/li\u003e\n  \u003cli\u003eControl panel and motor control center (MCC) assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation lines requiring reliable AC switching\u003c\/li\u003e\n  \u003cli\u003eRefrigeration and air-conditioning systems using A2L refrigerants (UL\/CSA approved)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eOEM machinery and process automation equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229122367771,"sku":"1SBL137001R1310","price":16.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl137001r1310-af09-30-10-13-contactor-ac-switching_6c51c654-3f64-4697-b526-2dd7c3420c83.webp?v=1777156767"},{"product_id":"abb-1sbl157001r1310-af12-30-10-13-power-contactor","title":"ABB 1SBL157001R1310 AF12-30-10-13 3-Pole 12A 690V AC 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12-30-10-13 power contactor (SKU: 1SBL157001R1310) is a 3-pole AC switching contactor rated at 28 A and 690 V IEC, designed for demanding industrial motor control and switching applications. Part of ABB's versatile AF-series lineup, the AF12-30-10-13 features a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), eliminating the need for multiple coil variants across global installations. Rated at 5.5 kW at 400 V AC (AC-3) and 7-1\/2 hp at 480 V UL, this compact contactor fits tightly in control panels with dimensions of only 45 mm × 86 mm × 77 mm and a lightweight 0.27 kg body.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12-30-10-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL157001R1310\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110335\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC (IEC) \/ 600 V (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-1\/2 hp @ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliance for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL Listed — Underwriters Laboratories safety certification for North America\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for heat pumps, air-conditioners, and dehumidifiers (ref: LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified — Canadian Standards Association approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 (LZGH2A2L):\u003c\/strong\u003e CSA standard for HVAC switching equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA household and commercial electrical equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA low-voltage switchgear and controlgear standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary quality standard for electrical products in China\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore equipment certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification and certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme (IEC System for Conformity Testing) — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — mechanical shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle and recover electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary assessment standard for recyclability and recoverability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHVAC systems — air-conditioners, heat pumps, compressors, and fans\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor belt motor control\u003c\/li\u003e\n  \u003cli\u003ePump and compressor on\/off switching in process industries\u003c\/li\u003e\n  \u003cli\u003eOEM control panels requiring compact, globally certified contactors\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations (ABS\/BV certified)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229123744027,"sku":"1SBL157001R1310","price":17.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl157001r1310-af12-30-10-13-contactor-ac-switching_5080cbad-1186-441e-b89c-1162048edbd1.webp?v=1777156812"},{"product_id":"abb-1sbl137001r1301-af09-30-01-13-power-contactor","title":"ABB 1SBL137001R1301 AF09-30-01-13 3-Pole 9A 690V 100-250V Coil AC\/DC Power Contactor","description":"\u003cp\u003eThe ABB AF09-30-01-13 (SKU: 1SBL137001R1301) is a 3-pole power contactor designed for AC switching applications, rated at 9A up to 690V AC with a wide-range 100–250V AC\/DC coil. Part of ABB's AF series, the AF09-30-01-13 delivers reliable performance for motor control and industrial automation environments, featuring a compact footprint of 45mm × 86mm × 77mm and weighing just 0.27 kg.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF09-30-01-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL137001R1301\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (4-pole, AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250V AC\/DC (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — EU market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories — North American safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — Canadian safety approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — mandatory for Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine industry approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification society certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme — international mutual recognition of safety test results\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — post-Brexit UK market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4 \/ IEC\/EN 60947-4 \/ IEC60947-4:\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ IEC60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:\u003c\/strong\u003e Canadian standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 \/ UL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL standard for heat pumps, air conditioners (A2L refrigerant)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 \/ CSA C22.2No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for air conditioning applications with A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2No.60335:\u003c\/strong\u003e Canadian standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused, upgraded, and recycled\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control circuits in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC systems, including air conditioners and heat pumps using A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor drive switching\u003c\/li\u003e\n  \u003cli\u003eLighting and resistive load control\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical installations (ABS, BV certified)\u003c\/li\u003e\n  \u003cli\u003eGlobal OEM applications requiring multi-market certifications (CE, UL, CSA, CCC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229124923675,"sku":"1SBL137001R1301","price":16.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/1SBC101011V0000_master.png?v=1782633626"},{"product_id":"abb-1sbl277001r1300-af30-30-00-13-contactor","title":"ABB 1SBL277001R1300 AF30-30-00-13 3-Pole 30A 690V 15kW Coil 100-250V AC\/DC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF30-30-00-13 (SKU: 1SBL277001R1300) is a 3-pole AC power contactor rated at 30A and 690V, delivering 15kW motor-switching performance with a wide-range 100–250V AC\/DC coil. Designed for demanding industrial automation and control panel applications, this AF-series contactor offers reliable AC switching in a compact 45 × 86 × 86 mm footprint weighing just 0.31 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF30-30-00-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL277001R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250V 50\/60Hz AC \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523111233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU low-voltage and EMC directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme international safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Harmonised international\/European general rules standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Harmonised international\/European contactors and motor-starters standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electronic and electrical products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL-listed standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL listing for electrical heat pumps, air conditioners and dehumidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e Canadian standard for heat pumps and air-conditioning equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e Canadian standard for safety of household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certification for Canadian and North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover raw materials from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Supplementary European standard covering environmental product assessment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU REACH regulation compliance — no substances of very high concern above threshold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor switching and control in HVAC systems, pumps, fans, and compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and control panel assembly\u003c\/li\u003e\n\u003cli\u003eBuilding services and commercial electrical installations\u003c\/li\u003e\n\u003cli\u003eMarine and offshore panel boards (DNV, LR, RINA approved)\u003c\/li\u003e\n\u003cli\u003eMachine tool and manufacturing line motor starters\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229125218587,"sku":"1SBL277001R1300","price":43.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl277001r1300-af30-30-00-13-contactor-ac-switching_bf35fb15-dc20-4e6b-ab2a-23debd5d5fba.webp?v=1777156899"},{"product_id":"abb-1sbl297001r1300-af38-30-00-13-50a-3p-contactor","title":"ABB 1SBL297001R1300 AF38-30-00-13 3-Pole 50A 690V 18.5kW Coil 100-250V AC\/DC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF38-30-00-13 (SKU: 1SBL297001R1300) is a 3-pole power contactor designed for AC switching applications, rated at 50 A and 690 V with a wide-range coil accepting 100–250 V AC\/DC. Part of ABB's proven AF series, this contactor delivers reliable motor switching up to 18.5 kW and is built to meet IEC 60947-4 and a comprehensive suite of global certifications — making it a trusted choice for industrial control panels, motor starter assemblies, and automation systems worldwide.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF38-30-00-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL297001R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523111530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL-listed for safety compliance in North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approved\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping certified for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme certification for international safety standard acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for household and similar electrical appliances — Part 2-40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification covering A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for appliance safety — Part 2-40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA safety standard for electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e International\/European standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e International\/European standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Harmonised IEC\/EN standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Harmonised IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing standard — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard on end-of-life aspects for networked equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Extended scope of EN 45555 for networked equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation systems up to 18.5 kW\u003c\/li\u003e\n  \u003cli\u003eControl panel and MCC (Motor Control Centre) assemblies\u003c\/li\u003e\n  \u003cli\u003eHVAC compressor and fan motor switching (including A2L refrigerant systems)\u003c\/li\u003e\n  \u003cli\u003eConveyor, pump, and fan drive control in manufacturing plants\u003c\/li\u003e\n  \u003cli\u003eDOL (Direct-On-Line) and star-delta motor starting schemes\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore applications (ABS\/BV certified)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and facility management systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229125480731,"sku":"1SBL297001R1300","price":54.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl297001r1300-af38-30-00-13-contactor-ac-switching_18a22661-19f3-4f43-b716-d7c4e0563906.webp?v=1777156917"},{"product_id":"abb-1sbl177001r1301-af16-30-01-13-30a-3pole-contactor","title":"ABB 1SBL177001R1301 AF16-30-01-13 3-Pole 30A 690V 7.5kW AF Series Power Contactor AC Switching 100-250V Coil","description":"\u003cp\u003eThe ABB AF16-30-01-13 power contactor (SKU: 1SBL177001R1301) is a 3-pole AC switching contactor rated at 30 A and 690 V, delivering 7.5 kW motor switching capability with a wide-range 100–250 V AC\/DC coil. Designed for demanding industrial automation and control panel applications, the AF16-30-01-13 belongs to ABB's proven AF series and complies with IEC 60947-4, UL, CSA, and a comprehensive set of global certifications — making it suitable for international deployments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF16-30-01-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL177001R1301\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110731\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage AC contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for HVAC equipment safety (LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA HVAC equipment safety standard (LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA household \u0026amp; similar appliances standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA low-voltage switchgear \u0026amp; controlgear standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine\/industrial certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme international safety certificate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear \u0026amp; controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear general rules (consolidated reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage contactors and motor starters (consolidated reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical \u0026amp; electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eControl panel and MCC (motor control centre) assemblies\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration equipment switching\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and conveyor motor starting\u003c\/li\u003e\n  \u003cli\u003eInternational installations requiring multi-standard certification (UL, CSA, IEC, CCC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229125742875,"sku":"1SBL177001R1301","price":20.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl177001r1301-af16-30-01-13-switching-100-250v-coil_f26c2248-34c6-4214-8263-7ffa32f082b3.webp?v=1777156837"},{"product_id":"abb-1sbl237001r1300-af26-30-00-13-45a-3p-contactor","title":"ABB 1SBL237001R1300 AF26-30-00-13 3-Pole 45A 690V 11kW AC\/DC Coil 100-250V Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF26-30-00-13 (SKU: 1SBL237001R1300) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 45 A and 690 V with an 11 kW power rating, this AF-series contactor features a wide-range 100–250 V AC\/DC coil, making it highly flexible for global installations. Compact at just 45 mm × 86 mm × 86 mm and weighing only 0.31 kg, the AF26-30-00-13 delivers reliable performance in space-constrained control cabinets.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF26-30-00-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL237001R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliance for the UK market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — required for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary quality certification for China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — independent third-party certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore industry certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — compliance mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine and industrial safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — international mutual recognition of safety test results\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC and EN standard for low-voltage switchgear — general\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC and EN standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL standard for heat pumps and air conditioners using A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:\u003c\/strong\u003e Canadian standard for electromechanical contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e Canadian standard for heat pumps using A2L refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e Canadian standard for household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — general CSA certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to repair, reuse, and recycle energy-related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Related standard for energy-related product sustainability assessment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — restriction of hazardous substances in products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliance with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — EU end-of-life product compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229127053595,"sku":"1SBL237001R1300","price":26.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl237001r1300-af26-30-00-13-contactor-ac-switching_f96f69b0-a29c-4d97-8bc4-49800bb0b589.webp?v=1777156869"},{"product_id":"abb-1sbl347001r1311-af40-30-11-13-contactor","title":"ABB 1SBL347001R1311 AF40-30-11-13 3-Pole 70A AC-1 18.5kW 690V 100-250V Coil AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF40-30-11-13 (SKU: 1SBL347001R1311) is a 3-pole AC power contactor from ABB's AF series, rated at 70 A AC-1 and 690 V IEC, delivering 18.5 kW at 400 V AC-3 for robust industrial AC switching applications. Featuring a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), the AF40-30-11-13 simplifies installation and reduces spares inventory across diverse control systems. Compact dimensions of 67 × 125.5 × 111 mm and a lightweight 0.99 kg profile make it ideal for high-density panel layouts in industrial automation and motor control centres.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF40-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL347001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 mm × 125.5 mm × 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523132139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL (UL 60335-2-40):\u003c\/strong\u003e UL-listed per UL 60335-2-40 for safety of electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL-certified per low-voltage switchgear general rules standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL-certified per contactors and motor starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA (CSA C22.2 No. 60335-2-40):\u003c\/strong\u003e CSA-certified per Canadian safety standard for electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA-certified per low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA-certified per contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA certification per safety of household electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA certification per low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-4:\u003c\/strong\u003e International standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-5:\u003c\/strong\u003e International standard for control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European standard for enclosure protection degrees (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability of electrical and electronic products to be repaired, reused, and upgraded\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-91:\u003c\/strong\u003e Supplementary European standard for repairability and upgradability assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval for marine and offshore use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB scheme certification — international mutual recognition of safety test results\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — required for sale in China\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment — compliant with EU Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control centres (MCC) for 3-phase induction motors up to 18.5 kW \/ 400 V\u003c\/li\u003e\n  \u003cli\u003eHVAC systems — compressor and fan motor switching including A2L refrigerant equipment\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and process control panels\u003c\/li\u003e\n  \u003cli\u003ePump stations and conveyor drive control\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and energy management systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229127545115,"sku":"1SBL347001R1311","price":72.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl347001r1311-af40-30-11-13-contactor-ac-switching_964d0429-e744-4f9b-b306-9a9b78c8ef97.jpg?v=1777156935"},{"product_id":"abb-1sbl397001r1311-af80-30-11-13-125a-3p-contactor","title":"ABB 1SBL397001R1311 AF80-30-11-13 3-Pole 125A 1000V AC-1 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF80-30-11-13 (SKU: 1SBL397001R1311) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 125 A (AC-1) and up to 1000 V IEC, it delivers 37 kW at 400 V AC (AC-3) with a wide-range 100–250 V AC\/DC coil, making it highly versatile across global installations. Part of ABB's AF series, this contactor combines robust performance with a compact 82 × 125.5 × 116 mm footprint and a weight of just 1.21 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF80-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL397001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3 @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — equivalent to CE for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL 60335-2-40 — UL Listed under file LZGH2A2L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e Contactors and motor-starters (UL standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA C22.2 No. 60335-2-40 — CSA certified under LZGH2A2L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules (CSA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e Contactors and motor-starters (CSA standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC CB Scheme — internationally recognised safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and industrial type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor starting and switching in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and pump control (AC-3 duty)\u003c\/li\u003e\n\u003cli\u003eControl panel integration for manufacturing machinery\u003c\/li\u003e\n\u003cli\u003eHeating and resistive load switching (AC-1 duty)\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS\/BV approved)\u003c\/li\u003e\n\u003cli\u003eGlobal deployments requiring UL\/CSA\/CE\/CCC multi-certification\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the coil voltage range for the AF80-30-11-13?\u003c\/strong\u003e The coil accepts 100–250 V AC\/DC at 50\/60 Hz, eliminating the need for multiple coil variants across different supply voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat auxiliary contacts are included?\u003c\/strong\u003e The AF80-30-11-13 configuration includes 1 NO + 1 NC auxiliary contacts (as indicated by the -11-13 designation).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this contactor suitable for UL-listed installations?\u003c\/strong\u003e Yes. It is UL Listed (UL 60947-4-1, UL 60335-2-40) and CSA certified, rated at 105 A general use and 60 hp at 480 V for North American applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the rated power for motor applications?\u003c\/strong\u003e 37 kW at 400 V AC under AC-3 duty (IEC), and 60 hp at 480 V (UL).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229127905563,"sku":"1SBL397001R1311","price":127.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl397001r1311-af80-30-11-13-contactor-ac-switching_359d8eb2-2da6-4976-a2d4-ce44a4b43901.jpg?v=1777156980"},{"product_id":"abb-1sbl177001r1310-af16-30-10-13-30a-3p-contactor","title":"ABB 1SBL177001R1310 AF16-30-10-13 3-Pole 30A 690V 7.5kW Coil 100-250V AC\/DC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF16-30-10-13 power contactor (SKU 1SBL177001R1310) is a 3-pole, 30 A AC switching contactor rated at 690 V with a wide-range 100–250 V AC\/DC coil, delivering 7.5 kW motor switching capability in a compact 45 × 86 × 77 mm footprint. Part of ABB's proven AF Series, the AF16-30-10-13 is engineered for demanding industrial automation and motor control applications where reliable, efficient AC switching is essential.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF16-30-10-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL177001R1310\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear — contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for particular requirements for electrical heat pumps, air-conditioners and dehumidifiers (LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for heat pumps and air-conditioners (LZGH2A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA standard series for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN low-voltage switchgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and offshore approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary EN 45555 standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (chemicals)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAC motor switching and control in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHVAC systems — heat pumps, air-conditioning units, and dehumidifiers\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies requiring compact, high-reliability switching\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and facility management electrical systems\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical installations (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eMachine tool and conveyor motor control circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229128200475,"sku":"1SBL177001R1310","price":20.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl177001r1310-af16-30-10-13-contactor-ac-switching_bad34d42-3d63-4ff4-95c4-3ad729bb9218.webp?v=1777156843"},{"product_id":"abb-1sbl407001r1311-af96-30-11-13-130a-3p-power-contactor","title":"ABB 1SBL407001R1311 AF96-30-11-13 3-Pole 130A AC-1 45kW 400V 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF96-30-11-13 power contactor (SKU: 1SBL407001R1311) is a 3-pole AC switching contactor rated at 130 A (AC-1) and 45 kW at 400 V AC (AC-3), designed for demanding industrial motor control and power switching applications. Part of ABB's proven AF Series, it features a wide-range coil accepting 100–250 V AC\/DC, simplifying installation across diverse control voltage systems. Compact at 82 × 125.5 × 116 mm and weighing just 1.21 kg, the AF96-30-11-13 delivers reliable performance up to 1000 V IEC \/ 600 V UL.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF96-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL407001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133334\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kW \/ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp \/ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL certification to general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL certification for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL certification for HVAC\/R equipment safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L refrigerant HVAC\/R applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA certification — general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA certification for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA certification for HVAC\/R equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant HVAC\/R applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association general approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e International\/European standard — general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e International\/European standard — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e International standard — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions for DIN rail mounting of electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing standard for industrial equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — internationally recognised safety test certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — approved for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and offshore classification approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial motor control and starting for pumps, fans, compressors, and conveyors\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration systems requiring A2L refrigerant-compatible switching\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eControl panels and MCC (Motor Control Centre) assemblies up to 1000 V IEC\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and industrial process control switchboards\u003c\/li\u003e\n  \u003cli\u003eApplications requiring broad control voltage flexibility (100–250 V AC\/DC single coil)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229128429851,"sku":"1SBL407001R1311","price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl407001r1311-af96-30-11-13-contactor-ac-switching_9df6bfbe-9113-40fa-aaa1-4d84c4d99d4c.jpg?v=1777156994"},{"product_id":"abb-1sbl387001r1311-af65-30-11-13-105a-3p-contactor","title":"ABB 1SBL387001R1311 AF65-30-11-13 3-Pole 105A 690V AC-1 30kW 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF65-30-11-13 power contactor (SKU: 1SBL387001R1311) is a 3-pole AC switching contactor rated at 105 A AC-1 and 690 V IEC, delivering 30 kW at 400 V AC-3 for demanding industrial motor and load control applications. Featuring a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz), the AF65-30-11-13 eliminates the need for separate AC and DC coil versions, simplifying spares inventory and panel design. Compact at 67 × 125.5 × 111 mm and weighing just 0.99 kg, it fits readily into space-constrained control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF65-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL387001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 \/ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL \/ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 mm × 125.5 mm × 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523132733\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU low voltage and EMC directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for heat pumps, air conditioners and dehumidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification covering A2L low-GWP refrigerant applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:22:\u003c\/strong\u003e CSA standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for HVAC equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA series standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA series standard for household and similar electrical appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification and certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — international safety certification mutual recognition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e International and European standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4 \/ IEC\/EN 60947-4:\u003c\/strong\u003e International and European standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e IEC standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC60068-2:\u003c\/strong\u003e Environmental testing standard — vibration, temperature, humidity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229128757531,"sku":"1SBL387001R1311","price":108.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl387001r1311-af65-30-11-13-contactor-ac-switching_538ceaac-37c3-4213-a9b2-789d2969a0d0.jpg?v=1777156971"},{"product_id":"abb-1sbl367001r1311-af52-30-11-13-100a-3p-contactor","title":"ABB 1SBL367001R1311 AF52-30-11-13 3-Pole 100A 690V AC-1 22kW AC-3 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF52-30-11-13 power contactor (SKU: 1SBL367001R1311) is a 3-pole AC switching contactor rated at 100 A (AC-1) and 690 V IEC, delivering 22 kW at 400 V AC-3, with a wide-range coil accepting 100–250 V AC\/DC (50\/60 Hz). Designed for demanding industrial environments, the AF52-30-11-13 features a compact footprint of 67 × 125.5 × 111 mm and a lightweight 0.99 kg construction, making it ideal for control panels and motor switching applications. Its universal coil eliminates the need for separate AC and DC versions, simplifying procurement and inventory management.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF52-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL367001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523132436\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL, 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 mm × 125.5 mm × 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU low voltage and EMC directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — for Great Britain market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine application approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and offshore certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Safety of household and similar electrical appliances — heat pumps, air conditioners\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL file reference for heat pump \/ HVAC application listing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules (UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e Contactors and motor starters (UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian standard for heat pumps and air conditioning equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA file reference for HVAC application listing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e Low-voltage switchgear general rules (CSA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e Contactors and motor starters (CSA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e Canadian Electrical Code product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ IEC60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-4:\u003c\/strong\u003e Contactors and motor starters (IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing — combined vibration and climate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, upgraded, and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-91:\u003c\/strong\u003e Supplement to EN45555 for specific product categories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals (EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor switching and control in industrial automation panels up to 22 kW \/ 400 V AC-3\u003c\/li\u003e\n  \u003cli\u003eHVAC and heat pump systems — UL 60335-2-40 and CSA C22.2 No. 60335-2-40 listed\u003c\/li\u003e\n  \u003cli\u003ePower distribution and load switching up to 100 A AC-1 \/ 690 V IEC\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations — ABS and Bureau Veritas approved\u003c\/li\u003e\n  \u003cli\u003eBuilding automation, pump control, compressor switching, and conveyor systems\u003c\/li\u003e\n  \u003cli\u003eApplications requiring universal 100–250 V AC\/DC coil flexibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229129019675,"sku":"1SBL367001R1311","price":91.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl367001r1311-af52-30-11-13-contactor-ac-switching_614c65df-c275-40d6-a0d3-c28414d602ba.jpg?v=1777156953"},{"product_id":"abb-1sfl547002r1311-af265-30-11-13-400a-power-contactor","title":"ABB 1SFL547002R1311 AF265-30-11-13 3-Pole 400A AC-1 132kW 1000V IEC Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF265-30-11-13 power contactor (SKU: 1SFL547002R1311) is a heavy-duty 3-pole AC switching contactor rated at 400 A (AC-1) and up to 1000 V IEC, delivering 132 kW at 400 V AC (AC-3) for demanding industrial applications. Part of ABB's AF series, the AF265-30-11-13 is engineered for high-current motor and load switching in control panels, machine automation, and industrial power distribution systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF265-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL547002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF265\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500481189\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V IEC \/ 600 V UL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW @ 400 V AC \/ 200 hp @ 480 V UL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263 x 203 x 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets (UL E36588)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC (CQC):\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas certification for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certification under IEC standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked standby-capable products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation (EC No 1907\/2006)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty motor switching and direct-on-line starting of large AC motors up to 132 kW \/ 200 hp\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution systems (DNV, LR, BV, RINA, CCS, PRS approved)\u003c\/li\u003e\n  \u003cli\u003eHVAC systems, compressors, pumps, and conveyor drive circuits\u003c\/li\u003e\n  \u003cli\u003eAutomation and process control in manufacturing plants\u003c\/li\u003e\n  \u003cli\u003eCapacitor bank switching and resistive load control up to 400 A AC-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229129347355,"sku":"1SFL547002R1311","price":686.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl547002r1311-af265-30-11-13-contactor-ac-switching_4c4a23f3-d3a3-4e3a-9a39-1bd2ff47e48e.webp?v=1777160315"},{"product_id":"abb-1sfl607002r1311-af370-30-11-13-600a-power-contactor","title":"ABB 1SFL607002R1311 AF370-30-11-13 3-Pole 600A 1000V AC-1 200kW Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF370-30-11-13 (SKU: 1SFL607002R1311) is a 3-pole AC power contactor rated at 600 A AC-1 and 1000 V IEC, delivering 200 kW at 400 V AC-3 for heavy-duty industrial switching applications. Part of ABB's trusted AF series, the AF370-30-11-13 is engineered for demanding control panel and motor switching duties where reliability, global certification, and high current capacity are non-negotiable. With a UL general-use rating of 520 A at 600 V and 300 hp at 480 V, this contactor bridges IEC and UL environments seamlessly.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF370-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL607002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e520 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3, 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL, 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263 × 203 × 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500481899\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical equipment safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US (UL) and Canadian (cUL) markets; UL File E36588\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC (CQC):\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for offshore and marine installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC EMC:\u003c\/strong\u003e Korean Certification for electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR (Lloyd's Register):\u003c\/strong\u003e Type approved by Lloyd's Register for marine and offshore use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków — Polish Ship Register approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB (SE-89316):\u003c\/strong\u003e International CB Scheme certificate for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL E36588:\u003c\/strong\u003e UL file number confirming North American listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for AC contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP rating standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-76:\u003c\/strong\u003e Specific product family requirements under EN 45555\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU RoHS directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty AC motor switching in industrial drives and compressor systems\u003c\/li\u003e\n\u003cli\u003eMain and distribution panel switching for large loads up to 600 A\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power distribution (DNV, LR, RINA, CCS, PRS approved)\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control panels requiring IEC 60947-4 compliance\u003c\/li\u003e\n\u003cli\u003eGlobal OEM installations requiring simultaneous IEC and UL\/CSA market coverage\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229129675035,"sku":"1SFL607002R1311","price":866.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl607002r1311-af370-30-11-13-contactor-ac-switching_56436831-c292-4711-82f7-0a1ebc61df92.webp?v=1777160357"},{"product_id":"abb-1sfl597001r7011-af460-30-11-70-700a-power-contactor","title":"ABB 1SFL597001R7011 AF460-30-11-70 3-Pole 700A 1000V AC-1 100-250V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF460-30-11-70 power contactor (SKU: 1SFL597001R7011) is a heavy-duty 3-pole AC switching contactor rated at 700 A (AC-1) and up to 1000 V IEC, designed for demanding industrial motor control and load switching applications. With a wide-range coil accepting 100–250 V AC\/DC at 50\/60 Hz, the AF460-30-11-70 eliminates the need for multiple coil variants and simplifies global installation. Rated at 250 kW at 400 V AC (AC-3), this contactor is engineered for continuous heavy industrial duty in control panels, motor starters, and automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF460-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL597001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500217658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current UL General Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 kW \/ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 hp \/ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC 50\/60 Hz \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 mm × 278 mm × 216 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Underwriters Laboratories — certified for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — Canadian electrical safety approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — approved for Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — approved for South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification society approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and energy industry certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine and industrial safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval and marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping — marine classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society — Chinese marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group — European low voltage certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e International standard for degrees of protection (IP ratings)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the recyclability and recoverability of electrical products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Zero Waste to Landfill standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals (EC 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty motor starting and stopping in industrial plants\u003c\/li\u003e\n\u003cli\u003eLarge pump and fan motor control in HVAC and water treatment\u003c\/li\u003e\u0026lt; li\u0026gt;Load switching in power distribution panels and motor control centres (MCCs)\u003cli\u003eOffshore and marine electrical installations requiring ABS, DNV, BV, LR, RINA, PRS, or CCS approval\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control systems\u003c\/li\u003e\n\u003cli\u003eResistive and inductive load switching up to 700 A AC-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229129969947,"sku":"1SFL597001R7011","price":1500.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl597001r7011-af460-30-11-70-contactor-ac-switching_ad53fbe0-e8fc-4606-8ca1-6b34a91ec7cf.webp?v=1777160345"},{"product_id":"abb-1sfl587002r1311-af305-30-11-13-power-contactor","title":"ABB 1SFL587002R1311 AF305-30-11-13 3-Pole 500A 1000V AC-1 160kW Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF305-30-11-13 power contactor (SKU: 1SFL587002R1311) is a heavy-duty 3-pole AC switching contactor rated at 500 A (AC-1) and 1000 V IEC, delivering 160 kW at 400 V AC-3 for demanding industrial motor and load control applications. Engineered for reliability in high-current switching environments, the AF305-30-11-13 is part of ABB's proven AF-series contactor range, combining wide coil voltage flexibility with comprehensive global certification coverage.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF305-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL587002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF305\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500481776\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging Dimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263 × 203 × 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for Korean market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale type approval for marine use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-76:\u003c\/strong\u003e Supplementary requirements for electrical switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty motor starting and switching in industrial automation and process control\u003c\/li\u003e\n  \u003cli\u003eControl panel integration for large motors up to 160 kW \/ 400 V (AC-3)\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution systems (DNV, LR, RINA, PRS, CCS, RINA approved)\u003c\/li\u003e\n  \u003cli\u003eHigh-current resistive and inductive load switching in manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003eBuilding services, HVAC, and infrastructure power control applications\u003c\/li\u003e\n  \u003cli\u003eApplications requiring global market compliance across IEC, UL, CSA, and CQC standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229130330395,"sku":"1SFL587002R1311","price":719.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl587002r1311-af305-30-11-13-contactor-ac-switching_b44a9538-6320-414d-84ce-b09c8041d2a4.webp?v=1777160334"},{"product_id":"abb-1sfl487002r1311-af190-30-11-13-275a-power-contactor","title":"ABB 1SFL487002R1311 AF190-30-11-13 3-Pole 275A 1000V AC-1 90kW AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF190-30-11-13 power contactor (SKU: 1SFL487002R1311) is a 3-pole AC switching contactor rated at 275 A (AC-1) and up to 1000 V IEC, engineered for demanding industrial motor control and power switching applications. Delivering 90 kW at 400 V AC (AC-3) and 125 hp at 480 V UL, the AF190-30-11-13 belongs to ABB's proven AF contactor series and is built to operate reliably across heavy-duty automation and control panel environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF190-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL487002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3 @ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500480434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market regulatory requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Certified by UL for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC CB Scheme certification for international market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approval for marine use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas approval for marine and offshore environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping marine approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty motor control and switching in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eControl panel integration for large AC motor loads up to 90 kW \/ 400 V\u003c\/li\u003e\n\u003cli\u003eMarine and offshore electrical installations (BV, DNV, LR, RINA, CCS, PRS approved)\u003c\/li\u003e\n\u003cli\u003ePower distribution switching in manufacturing, process, and infrastructure plants\u003c\/li\u003e\n\u003cli\u003eNorth American installations requiring UL\/cULus and CSA compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229130658075,"sku":"1SFL487002R1311","price":350.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl487002r1311-af190-30-11-13-contactor-ac-switching_db45dab5-09f9-48b1-896f-fb74c47d2e7c.webp?v=1777160281"},{"product_id":"abb-1sfl427001r1311-af116-30-11-13-160a-contactor","title":"ABB 1SFL427001R1311 AF116-30-11-13 3-Pole 160A 690V 55kW AC Switching Power Contactor","description":"\u003cp\u003eThe ABB AF116-30-11-13 (SKU: 1SFL427001R1311) is a 3-pole AC switching power contactor rated at 160 A and 690 V, delivering up to 55 kW of motor switching capacity for demanding industrial applications. Designed for continuous duty in control panels and motor control centres, the AF116-30-11-13 provides reliable, high-performance switching backed by an extensive portfolio of international certifications including CE, cULus, DNV, and IEC 60947-4 compliance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF116-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL427001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 × 216 × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500476376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to EU directives for safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for Great Britain market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for Canada and USA (File E36588)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL E36588:\u003c\/strong\u003e UL listing file reference for North American compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC Safety:\u003c\/strong\u003e Korean Certification for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC EMC:\u003c\/strong\u003e Korean Certification for electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków (Polish Ship Register) approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale type approved for marine installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approved for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEMKO:\u003c\/strong\u003e Swedish electrical safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Ingress protection classification standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked standby and off-mode related aspects of networked equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-87:\u003c\/strong\u003e Supplementary energy efficiency standard requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation compliance for chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor control centres (MCC) for industrial drives up to 55 kW\u003c\/li\u003e\n\u003cli\u003ePump and fan control in HVAC, water treatment, and process plants\u003c\/li\u003e\n\u003cli\u003eCompressor and conveyor switching in manufacturing automation\u003c\/li\u003e\n\u003cli\u003eMarine and offshore electrical installations (DNV, LR, RINA, PRS, CCS approved)\u003c\/li\u003e\n\u003cli\u003eHeavy-duty AC switching in control panels up to 690 V\u003c\/li\u003e\n\u003cli\u003eMachine automation and industrial control systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229130887451,"sku":"1SFL427001R1311","price":243.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl427001r1311-af116-30-11-13-switching-power-contactor_8bc23527-a134-4b2a-8737-aeec7ddef609.webp?v=1777160228"},{"product_id":"abb-1sfl527002r1311-af205-30-11-13-350a-power-contactor","title":"ABB 1SFL527002R1311 AF205-30-11-13 3-Pole 350A 1000V AC-1 110kW Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF205-30-11-13 power contactor (SKU: 1SFL527002R1311) is a heavy-duty 3-pole AC switching contactor rated at 350 A (AC-1) and 1000 V IEC, delivering 110 kW at 400 V AC-3 for demanding industrial motor and load control applications. Part of ABB's proven AF series, the AF205-30-11-13 is engineered for high-cycle switching in control panels, motor starters, and automation systems where reliability and global certification compliance are non-negotiable.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF205-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL527002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500480564\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3 @ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e258 mm × 160 mm × 235 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for safety, health, and environmental protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus (UL E36588):\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC \/ CQC:\u003c\/strong\u003e China Compulsory Certification; CQC certificates CQC2014010304676685 and CQC2014010304724672\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR (Lloyd's Register):\u003c\/strong\u003e Certified for shipboard and marine installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval classification society approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society — approved for marine use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC Safety \u0026amp; KC EMC:\u003c\/strong\u003e Korean Certification for safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków — Polish Register of Shipping approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555 \/ EN 45555-79:\u003c\/strong\u003e General methods for assessment of the recyclability and recoverability of electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrical engineering association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229131149595,"sku":"1SFL527002R1311","price":362.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl527002r1311-af205-30-11-13-contactor-ac-switching_f00c4a9f-cae7-4727-991d-6d357bffbd9f.webp?v=1777160300"},{"product_id":"abb-1sfl447001r1311-af140-30-11-13-200a-contactor","title":"ABB 1SFL447001R1311 AF140-30-11-13 3-Pole 200A 690V 75kW AC Switching Power Contactor","description":"\u003cp\u003eThe ABB AF140-30-11-13 power contactor (SKU: 1SFL447001R1311) is a 3-pole AC switching contactor rated at 200 A and 690 V, delivering motor switching capability up to 75 kW. Designed for demanding industrial automation and control panel applications, this AF-series contactor combines robust construction with a comprehensive suite of global certifications including CE, cULus, IEC 60947-4, DNV, and marine approvals, making it suitable for both land-based and offshore installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF140-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL447001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 × 216 × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500476949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for market access across the EEA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approval for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas certification for marine and offshore use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme certification for international market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society approval for marine installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for offshore and marine environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków (Polish Register of Shipping) approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale certification for marine installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for AC contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European harmonised standard for enclosure protection degrees\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover critical raw materials from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard for electrical vehicle supply equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial motor switching and control in manufacturing plants and process industries\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies requiring high-current AC switching up to 200 A\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical installations (ABS, BV, DNV, LR, RINA, CCS, PRS approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC systems requiring robust power contactors\u003c\/li\u003e\n  \u003cli\u003ePump, compressor, and conveyor motor control applications up to 75 kW\u003c\/li\u003e\n  \u003cli\u003eInternational projects demanding multi-market certification compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229131411739,"sku":"1SFL447001R1311","price":260.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl447001r1311-af140-30-11-13-switching-power-contactor_b7979444-719f-4fcb-a9ce-aa90d93cc062.webp?v=1777160247"},{"product_id":"abb-1sfl467001r1311-af146-30-11-13-225a-contactor","title":"ABB 1SFL467001R1311 AF146-30-11-13 3-Pole 225A 1000V AC-1 75kW Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF146-30-11-13 (SKU: 1SFL467001R1311) is a heavy-duty 3-pole power contactor designed for AC switching applications in industrial automation and motor control. Rated at 225 A (AC-1) and up to 1000 V IEC, this contactor delivers reliable switching performance for loads up to 75 kW at 400 V AC (AC-3) or 100 hp at 480 V UL, making it an ideal choice for demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF146-30-11-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL467001R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500476994\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Dimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 mm × 216 mm × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market regulatory requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both Canadian and US markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — meets Chinese compulsory certification standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC Safety:\u003c\/strong\u003e Korea Certification for electrical safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC EMC:\u003c\/strong\u003e Korea Certification for electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR (Lloyd's Register):\u003c\/strong\u003e Approved for marine installation and shipbuilding applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping — marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian naval register marine approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society — marine and offshore equipment approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e International standard for degrees of protection provided by enclosures (IP rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-87:\u003c\/strong\u003e Extended assessment criteria for electrical and electronic equipment recoverability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for Canadian electrical safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulations on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor control and switching in industrial automation panels\u003c\/li\u003e\n\u003cli\u003eHeavy-duty AC switching up to 1000 V IEC for manufacturing equipment\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (DNV, LR, RINA, PRS, CCS, and PRS approved)\u003c\/li\u003e\n\u003cli\u003eLarge motor starters for pumps, compressors, and conveyors up to 75 kW \/ 100 hp\u003c\/li\u003e\n\u003cli\u003eControl panel integration in process industries, utilities, and building automation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229131673883,"sku":"1SFL467001R1311","price":274.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl467001r1311-af146-30-11-13-contactor-ac-switching_6a714411-8b86-41f6-b991-c78cb3ba27f3.webp?v=1777160268"},{"product_id":"abb-1sbl137001r1110-af09-30-10-11-3p-9a-contactor","title":"ABB 1SBL137001R1110 AF09-30-10-11 3-Pole 9A 24-60V AC\/DC Coil 690V Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF09-30-10-11 (SKU: 1SBL137001R1110) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel installations. Rated at 9A with a wide-range coil accepting 24–60V AC (50\/60Hz) and 20–60V DC, the AF09-30-10-11 delivers reliable motor and load switching at voltages up to 690V AC — making it a versatile choice for global installations where supply voltage may vary.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF09-30-10-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL137001R1110\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110014\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (400V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the UK market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for the North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage motor starters and contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for particular requirements for electrical heat pumps, air-conditioners and dehumidifiers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification covering A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for heat pumps and air-conditioning equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme international safety certification (IEC system)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electronic and electrical items\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1 (implicit via UL\/CSA alignment):\u003c\/strong\u003e Electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, upgraded and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-92:\u003c\/strong\u003e Specific assessment methods for energy-related products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect-on-line (DOL) motor starting for small three-phase motors up to 4 kW at 400V\u003c\/li\u003e\n  \u003cli\u003eHVAC systems including heat pumps and air-conditioning units using A2L refrigerants\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels requiring compact, DIN-rail compatible switching\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations — ABS and BV type-approved\u003c\/li\u003e\n  \u003cli\u003eGlobal OEM machinery where a wide-range coil (24–60V AC\/DC) simplifies design across multiple supply standards\u003c\/li\u003e\n  \u003cli\u003ePump and fan control in building services and process automation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229131968795,"sku":"1SBL137001R1110","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl137001r1110-af09-30-10-11-contactor-ac-switching_1b309f6d-af05-4275-b985-bb42483eacec.webp?v=1777156760"},{"product_id":"abb-1sbl157001r1110-af12-30-10-11-3p-12a-contactor","title":"ABB 1SBL157001R1110 AF12-30-10-11 3-Pole 12A 24-60V AC\/DC Coil AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12-30-10-11 power contactor (SKU: 1SBL157001R1110) is a 3-pole AC switching contactor from ABB's AF series, rated at 12A with a wide-range coil input of 24–60V AC (50\/60Hz) and 20–60V DC. Designed for industrial motor control and automation applications, it delivers reliable switching at up to 690V AC with a 5.5kW power rating, in a compact 45mm × 86mm × 77mm package weighing just 0.27kg.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12-30-10-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL157001R1110\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110311\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant with UK market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear — AC motor contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for safety of heat pumps, air conditioners, and dehumidifiers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:\u003c\/strong\u003e CSA standard for AC motor contactors and starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for HVAC and refrigerant equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA general standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA general standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — voluntary certification for quality assurance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — international classification and certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme — international IEC safety certification mutual recognition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Consolidated IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Consolidated IEC\/EN standard for contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions for DIN rail mounting of electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle and recover\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e End-of-life treatment of electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control and starting in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHVAC system switching — compatible with A2L refrigerant equipment (UL\/CSA 60335-2-40)\u003c\/li\u003e\n  \u003cli\u003eControl panel assembly for machine builders and OEMs\u003c\/li\u003e\n  \u003cli\u003ePump and fan motor switching in building services\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore installations (ABS\/BV approved)\u003c\/li\u003e\n  \u003cli\u003eApplications requiring wide-band coil voltage (24–60V AC\/DC) for simplified panel design\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229132263707,"sku":"1SBL157001R1110","price":22.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl157001r1110-af12-30-10-11-contactor-ac-switching_b285b78b-d22a-4701-ba3a-daf65e48f03b.webp?v=1777156800"},{"product_id":"abb-1sfl657001r7011-af1350-30-11-70-power-contactor","title":"ABB 1SFL657001R7011 AF1350-30-11-70 3-Pole 1350A 1000V 475kW AF Series Power Contactor","description":"\u003cp\u003eThe ABB AF1350-30-11-70 power contactor (SKU: 1SFL657001R7011) is a heavy-duty 3-pole switching device rated at 1350 A and 1000 V, delivering up to 475 kW of motor switching capacity within the ABB AF series. Designed for demanding industrial automation and power distribution applications, it features a universal coil accepting 100–250 V AC (50\/60 Hz) or 100–250 V DC, making it ideal for global deployments across diverse control systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF1350-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL657001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500250143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (30-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1350 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e475 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC 50\/60 Hz \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e438 mm × 392 mm × 244 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union electromagnetic compatibility and low-voltage directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by UL for both US (UL) and Canadian (cUL) markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society marine and offshore approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine and offshore installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for the South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group international standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków (Polish Ship Register) marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale marine classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ IEC 60947-4 \/ IEC 60947-1:\u003c\/strong\u003e Compliant with IEC low-voltage switchgear and controlgear standards for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Zero waste to landfill standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty motor starting and switching in industrial plants, mills, and process industries\u003c\/li\u003e\n\u003cli\u003ePower distribution panels requiring high-current switching up to 1350 A\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations — certified by DNV, LR, RINA, PRS, and CCS\u003c\/li\u003e\n\u003cli\u003eGlobal automation systems leveraging the universal 100–250 V AC\/DC coil\u003c\/li\u003e\n\u003cli\u003eLarge compressor, pump, and fan drives rated up to 475 kW\u003c\/li\u003e\n\u003cli\u003eControl panels in energy, mining, oil \u0026amp; gas, and heavy manufacturing sectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229132591387,"sku":"1SFL657001R7011","price":2886.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl657001r7011-af1350-30-11-70-series-power-contactor_0f0a5605-84d2-40de-9792-d3f3b9fee504.webp?v=1777160383"},{"product_id":"abb-1sfl637001r7011-af750-30-11-70-power-contactor","title":"ABB 1SFL637001R7011 AF750-30-11-70 3-Pole 1050A 1000V AC-1 400kW AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF750-30-11-70 power contactor (SKU: 1SFL637001R7011) is a heavy-duty 3-pole AC switching contactor rated at 1050 A (AC-1) and up to 1000 V IEC, delivering 400 kW at 400 V AC (AC-3). Designed for demanding industrial motor control and power switching applications, the AF750-30-11-70 features a wide-range coil accepting 100–250 V AC (50\/60 Hz) or 100–250 V DC, maximising compatibility across global installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF750-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL637001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1050 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 kW \/ 400 V AC (AC-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 hp \/ 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC 50\/60 Hz \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm × 283 mm × 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500217702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — authorised for Great Britain market placement\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL Listed for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society — marine\/offshore use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and industrial type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — marine certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping — marine type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme — international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60529:\u003c\/strong\u003e European harmonised IP enclosure protection standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Standard for electrical waste recycling systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation, and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty motor switching and reversing in industrial plant environments\u003c\/li\u003e\n  \u003cli\u003eHigh-power pump, compressor, and fan drive control up to 400 kW\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore power distribution panels (ABS, BV, DNV, LR, RINA, PRS approved)\u003c\/li\u003e\n  \u003cli\u003ePower distribution and capacitor bank switching in control panels up to 1000 V IEC\u003c\/li\u003e\n  \u003cli\u003eAutomation and process control in oil \u0026amp; gas, mining, steel, and water treatment industries\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229132886299,"sku":"1SFL637001R7011","price":2392.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl637001r7011-af750-30-11-70-contactor-ac-switching_62b96885-9654-4caa-8e00-907d3a9a02c2.webp?v=1777160371"},{"product_id":"abb-1sfl647001r7011-af1250-30-11-70-1260a-power-contactor","title":"ABB 1SFL647001R7011 AF1250-30-11-70 3-Pole 1260A 1000V AC\/DC Coil 100-250V Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF1250-30-11-70 (SKU: 1SFL647001R7011) is a heavy-duty 3-pole power contactor rated for AC switching applications at up to 1260 A (AC-1) and 1000 V IEC, designed for demanding industrial power distribution, motor control, and load switching tasks. Part of ABB's proven AF-series contactor range, the AF1250-30-11-70 features a wide-range AC\/DC coil accepting 100–250 V, making it suitable for flexible global deployment across diverse control systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF1250-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL647001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF1250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500355091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1260 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1210 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm × 344 mm × 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European low-voltage and EMC directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for post-Brexit Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed for both US and Canadian markets by UL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL-listed per applicable UL standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Certified per UL 2799 requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification Mark for South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval for marine \u0026amp; offshore\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polish Register of Shipping type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale type approval for marine use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verified by Verband der Elektrotechnik (Germany)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ IEC60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — vibration, temperature, humidity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recycle and recover electrical\/electronic products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh-current industrial motor control centres (MCCs) and power distribution panels\u003c\/li\u003e\n\u003cli\u003eLarge pump, compressor, fan, and HVAC system switching\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power distribution (DNV, LR, PRS, RINA approved)\u003c\/li\u003e\n\u003cli\u003eHeavy industrial machinery and process automation switching\u003c\/li\u003e\n\u003cli\u003eRenewable energy and generator control applications\u003c\/li\u003e\n\u003cli\u003eGlobal installations requiring a single universal coil voltage (100–250 V AC\/DC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229133279515,"sku":"1SFL647001R7011","price":2869.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl647001r7011-af1250-30-11-70-contactor-ac-switching_02d8b2e9-4669-445a-9ba2-4a87a10d8851.webp?v=1777160377"},{"product_id":"abb-1sfl677001r7011-af1650-30-11-70-power-contactor","title":"ABB 1SFL677001R7011 AF1650-30-11-70 3-Pole 1650A 1000V 560kW AC Switching Power Contactor","description":"\u003cp\u003eThe ABB AF1650-30-11-70 power contactor (SKU: 1SFL677001R7011) is a heavy-duty 3-pole AC switching contactor rated at 1650 A and 1000 V, delivering up to 560 kW of motor switching capacity. Designed for demanding industrial applications, this contactor features a wide-range coil accepting 100–250 V AC (50\/60 Hz) or 100–250 V DC, enabling simplified panel design across global installations. Part of ABB's proven AF series, the AF1650-30-11-70 is engineered for high-cycle reliability in motor control centres, power distribution, and large drive applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF1650-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL677001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1650 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e560 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC (50\/60 Hz) \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Contacts Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO (30) + 1 NO + 1 NC auxiliary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e438 mm × 392 mm × 244 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500249703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL and CSA dual-certified for US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification — compliant for Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas — marine and offshore industry approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification — compliant for South Korean market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register — marine and industrial type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków — Polish maritime classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale — Italian maritime classification approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e International standard for low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked standby and related products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-71:\u003c\/strong\u003e Specific requirements supplement to EN 45555 for this product category\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment — compliant with EU Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLarge motor starting and switching in industrial motor control centres (MCC)\u003c\/li\u003e\n\u003cli\u003eHigh-current power distribution and bus switching in industrial plants\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power systems (DNV, LR, RINA, PRS approved)\u003c\/li\u003e\n\u003cli\u003eHeavy-duty HVAC, compressor, and pump control applications\u003c\/li\u003e\n\u003cli\u003eLarge variable speed drive bypass and line contactor duty\u003c\/li\u003e\n\u003cli\u003ePower factor correction capacitor bank switching\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229133574427,"sku":"1SFL677001R7011","price":4308.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl677001r7011-af1650-30-11-70-switching-power-contactor_863a0013-f8c0-495b-956f-1fc05dca8e29.webp?v=1777160391"},{"product_id":"abb-1sbl137001r1101-af09-30-01-11-3p-9a-contactor","title":"ABB 1SBL137001R1101 AF09-30-01-11 3-Pole 9A 690V AC 24-60V Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF09-30-01-11 power contactor (SKU: 1SBL137001R1101) is a 3-pole AC switching contactor rated for 9A continuous current at up to 690V AC, delivering 4 kW motor switching capability. Featuring a wide-range coil accepting 24–60V AC (50\/60Hz) and 20–60V DC, the AF09-30-01-11 is engineered for industrial control panels, machine automation, and motor starter assemblies where reliable, space-efficient switching is critical.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF09-30-01-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL137001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110113\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60V AC 50\/60Hz \/ 20–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformity with European Union safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for particular requirements for electrical heat pumps, air conditioners and dehumidifiers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L low-GWP refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA standard for heat pumps, air conditioners and dehumidifiers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e CSA standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA household and similar electrical appliances standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA low-voltage switchgear and controlgear standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for voluntary product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC System of Conformity Assessment for Electrotechnical Equipment and Components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping marine product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1 \/ IEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4 \/ IEC\/EN 60947-4 \/ IEC60947-4:\u003c\/strong\u003e Contactors and motor starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5 \/ IEC60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-227:\u003c\/strong\u003e Environmental testing — vibration test method\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired, reused and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary requirements for specific energy-related product categories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e3-phase motor switching and direct-on-line (DOL) motor starters in industrial machinery\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration system control with A2L refrigerant compatibility (UL\/CSA 60335-2-40)\u003c\/li\u003e\n  \u003cli\u003eControl panel and MCC (Motor Control Centre) assemblies\u003c\/li\u003e\n  \u003cli\u003ePump, fan, and compressor control in building automation systems\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore applications (ABS, BV approved)\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and process control across global markets (CE, UKCA, CCC, UL, CSA)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229133869339,"sku":"1SBL137001R1101","price":21.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl137001r1101-af09-30-01-11-contactor-ac-switching_88e1857e-d7b3-412a-b04b-e97716e466ed.webp?v=1777156754"},{"product_id":"abb-1sfl617001r7011-af580-30-11-70-800a-contactor","title":"ABB 1SFL617001R7011 AF580-30-11-70 3-Pole 800A 1000V AC-1 315kW Coil 100-250V AC\/DC Power Contactor","description":"\u003cp\u003eThe ABB AF580-30-11-70 power contactor (SKU 1SFL617001R7011) is a heavy-duty 3-pole AC switching contactor rated at 800 A (AC-1) and 1000 V IEC, delivering 315 kW at 400 V AC (AC-3). Designed for demanding industrial automation and control panel applications, the AF580-30-11-70 features a wide-range coil accepting 100–250 V AC\/DC at 50\/60 Hz, minimising the need for multiple spare variants across global installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF580-30-11-70\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFL617001R7011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF580\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500217696\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower contactor, AC switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current UL General Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 \/ 400 V IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL \/ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–250 V AC (50\/60 Hz) \/ 100–250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL listed for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korea Certification mark for South Korean market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLOVAG:\u003c\/strong\u003e Low Voltage Agreement Group certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Det Norske Veritas type approval for marine and offshore\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLR:\u003c\/strong\u003e Lloyd's Register type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCS:\u003c\/strong\u003e China Classification Society type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePRS:\u003c\/strong\u003e Polski Rejestr Statków (Polish Register of Shipping) approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRINA:\u003c\/strong\u003e Registro Italiano Navale type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4:\u003c\/strong\u003e Low-voltage switchgear — electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessment of the ability to repair, reuse, and recycle products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-69:\u003c\/strong\u003e Supplementary standard for switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — substances of very high concern compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-power motor switching and control in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eControl panel assembly for pumps, compressors, fans, and large drives\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical distribution switchboards (DNV, ABS, LR, BV, RINA, CCS, PRS approved)\u003c\/li\u003e\n  \u003cli\u003eBuilding services — HVAC plant rooms requiring heavy-duty switching\u003c\/li\u003e\n  \u003cli\u003eProcess industry installations requiring IEC 60947-4 compliant contactors\u003c\/li\u003e\n  \u003cli\u003eGlobal OEM equipment requiring a single coil variant across 100–250 V AC\/DC supply systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229134164251,"sku":"1SFL617001R7011","price":1806.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfl617001r7011-af580-30-11-70-ac-dc-power-contactor_680ae3ad-cdb6-40ff-8615-276181305266.webp?v=1777160367"},{"product_id":"abb-1sbl297001r1100-af38-30-00-11-50a-3p-contactor","title":"ABB 1SBL297001R1100 AF38-30-00-11 3-Pole 50A 690V AC 24-60V\/20-60VDC Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF38-30-00-11 (SKU: 1SBL297001R1100) is a 3-pole power contactor designed for AC switching applications, rated at 50 A and up to 690 V IEC \/ 600 V UL, delivering 18.5 kW at 400 V AC (AC-3). Part of ABB's AF Series, the AF38-30-00-11 features a wide-range coil accepting 24–60 V AC (50\/60 Hz) and 20–60 V DC, making it highly adaptable for diverse control system voltages in industrial automation and control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF38-30-00-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL297001R1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523111516\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking for EU market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine\/industrial certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme international safety certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for HVAC equipment safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian standard for HVAC equipment safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for AC contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL listing for HVAC application use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2No.60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA listing for HVAC application use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2No.60947-4-1:\u003c\/strong\u003e CSA standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, or recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Supplementary standard for energy-related product sustainability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2No.60335:\u003c\/strong\u003e CSA group standard for appliance and equipment safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2No.60947:\u003c\/strong\u003e CSA group standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor switching and control in industrial automation and manufacturing\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and fan motor control (UL 60335-2-40 listed)\u003c\/li\u003e\n\u003cli\u003eControl panel integration requiring wide-range coil voltage (24–60 V AC\/DC)\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS, BV certified)\u003c\/li\u003e\n\u003cli\u003eBuilding management systems and commercial electrical infrastructure\u003c\/li\u003e\n\u003cli\u003eApplications requiring simultaneous AC and DC coil compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229135180059,"sku":"1SBL297001R1100","price":68.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl297001r1100-af38-30-00-11-contactor-ac-switching_0f06f38d-b917-4c91-837e-2bffec264f72.webp?v=1777156912"},{"product_id":"abb-1sbl237001r1100-af26-30-00-11-45a-3p-contactor","title":"ABB 1SBL237001R1100 AF26-30-00-11 3-Pole 45A 690V 11kW 24-60V AC\/DC Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF26-30-00-11 (SKU: 1SBL237001R1100) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Part of ABB's AF-series, this contactor delivers a rated current of 45 A at up to 690 V AC, with an 11 kW power rating and a wide-range coil accepting 24–60 V AC (50\/60 Hz) and 20–60 V DC — enabling flexible integration across diverse power supply configurations. Its compact 45 × 86 × 86 mm footprint and lightweight 0.31 kg construction make it ideal for space-constrained installations on DIN rail or panel assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF26-30-00-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL237001R1100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF26\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110915\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IECEE CB Scheme international safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories product safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for safety of heat pumps and air conditioners\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian standard for heat pump and A\/C equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA certification for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e CSA standard for household and similar electrical appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters — electromechanical contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Harmonised international\/European standard for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Harmonised international\/European standard for contactors and starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing — mechanical and climatic test methods\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e General methods for assessing the energy-related aspects of networked products\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substances — compliance verified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229135507739,"sku":"1SBL237001R1100","price":32.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl237001r1100-af26-30-00-11-contactor-ac-switching_53ab5d05-33ba-4fa0-9db3-75275b80ab5f.webp?v=1777156861"},{"product_id":"abb-1sbl157001r1101-af12-30-01-11-power-contactor","title":"ABB 1SBL157001R1101 AF12-30-01-11 3-Pole 12A 24-60V AC\/DC Coil AF Series Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF12-30-01-11 power contactor (SKU: 1SBL157001R1101) is a 3-pole AC switching contactor rated at 28 A and 690 V, delivering 5.5 kW motor power. Part of ABB's proven AF Series, the AF12-30-01-11 features a wide-range coil accepting 24–60 V AC (50\/60 Hz) and 20–60 V DC, enabling flexible integration across diverse control panel and industrial automation applications. Compact at 45 × 86 × 77 mm and weighing just 0.27 kg, it is engineered for reliable, space-efficient performance in demanding electrical installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF12-30-01-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL157001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V AC 50\/60 Hz \/ 20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — product compliance for the UK market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for particular requirements for electrical heat pumps, air conditioners and dehumidifiers (file LZGH2A2L)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947-4-1:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335-2-40 (LZGH2A2L):\u003c\/strong\u003e CSA standard for heat pumps, air conditioners and dehumidifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60335:\u003c\/strong\u003e CSA standard for household and similar electrical appliances — safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification Centre voluntary certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e CB Scheme — international safety certification under IECEx framework\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping — marine type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas — marine and offshore type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions for low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-92:\u003c\/strong\u003e Supplementary standard for recoverability of electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229135835419,"sku":"1SBL157001R1101","price":22.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl157001r1101-af12-30-01-11-contactor-ac-switching_6da8a5a6-45a2-4d66-8808-a491ca464bdd.webp?v=1777156790"},{"product_id":"abb-1sbl397001r1111-af80-30-11-11-125a-3p-contactor","title":"ABB 1SBL397001R1111 AF80-30-11-11 3-Pole 125A AC-1 37kW 400V Coil 24-60V AC\/DC Contactor","description":"\u003cp\u003eThe ABB AF80-30-11-11 contactor (SKU 1SBL397001R1111) is a 3-pole industrial power contactor rated 125 A AC-1 and 37 kW at 400 V (AC-3), designed for demanding motor switching and load control applications. Part of ABB's AF Series, the AF80-30-11-11 accepts a wide-range coil voltage of 24–60 V AC (50\/60 Hz) and 20–60 V DC, enabling flexible integration across international control systems without the need for multiple coil variants.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF80-30-11-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL397001R1111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523133013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (AC-3 \/ 400 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (UL \/ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage AC (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1, AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 mm × 125.5 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety and EMC requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval for marine applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certificate for global market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Safety of household and commercial electrical appliances — heat pumps, HVAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian equivalent for HVAC\/heat pump appliances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear, general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for AC electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2A2L:\u003c\/strong\u003e UL file reference for HVAC appliance certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2A2L:\u003c\/strong\u003e CSA file reference for HVAC appliance certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA standard for AC contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN low-voltage switchgear general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrotechnical products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability of energy-related products to be repaired and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e General CSA electrical safety standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substance safety (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase AC motor switching and direct-on-line (DOL) motor starting up to 37 kW \/ 400 V\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and fan motor control in commercial and industrial buildings\u003c\/li\u003e\n\u003cli\u003ePump and conveyor motor control in process industries\u003c\/li\u003e\n\u003cli\u003eResistive and inductive load switching in industrial automation panels\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS, BV approved)\u003c\/li\u003e\n\u003cli\u003eNorth American applications requiring UL\/CSA listed 60 hp \/ 480 V contactors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229136097563,"sku":"1SBL397001R1111","price":158.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl397001r1111-af80-30-11-11-24-60v-ac-dc-contactor_68b1a86f-ee10-4cc8-b885-b62d7a703cfe.jpg?v=1777156975"},{"product_id":"abb-1sbl387001r1111-af65-30-11-11-power-contactor","title":"ABB 1SBL387001R1111 AF65-30-11-11 3-Pole 105A 690V AC 30kW Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF65-30-11-11 (SKU: 1SBL387001R1111) is a 3-pole power contactor designed for AC switching applications in industrial automation and control panel environments. Rated at 105 A AC-1 and 30 kW at 400 V AC (AC-3), this AF-series contactor supports up to 690 V IEC and 600 V UL, making it suitable for demanding motor control and load switching duties across a wide range of industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF65-30-11-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL387001R1111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (AC-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (UL General Use)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (UL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (AC-3 @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower (UL @ 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 mm × 125.5 mm × 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523132719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529 \/ EN 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e Safety of household and similar appliances — heat pumps, air-conditioners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL listing for A2L refrigerant applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-1:22:\u003c\/strong\u003e CSA standard for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:22:\u003c\/strong\u003e CSA standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e CSA safety standard for heat pump \/ air-conditioning equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA listing for A2L refrigerant applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 \/ CSA:\u003c\/strong\u003e General Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping marine certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas marine and industrial certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e IEC CB scheme international certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking — meets EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU chemical substance regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor control and starting in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eLoad switching in control panels and motor control centres (MCCs)\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and pump control, including A2L refrigerant applications\u003c\/li\u003e\n\u003cli\u003eMachine tool and conveyor drive switching\u003c\/li\u003e\n\u003cli\u003eBuilding automation and energy management systems\u003c\/li\u003e\n\u003cli\u003eMarine and offshore installations (ABS \/ BV certified)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229136326939,"sku":"1SBL387001R1111","price":135.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl387001r1111-af65-30-11-11-contactor-ac-switching_de1b6e3c-3de7-4762-a884-80476da7264e.jpg?v=1777156967"},{"product_id":"abb-1sbl177001r1101-af16-30-01-11-30a-3p-contactor","title":"ABB 1SBL177001R1101 AF16-30-01-11 3-Pole 30A 690V 7.5kW 24-60V AC\/DC Coil Power Contactor AC Switching","description":"\u003cp\u003eThe ABB AF16-30-01-11 (SKU: 1SBL177001R1101) is a 3-pole power contactor designed for AC switching applications in industrial control panels and motor circuits. Rated at 30 A and 690 V with a 7.5 kW motor power rating, the AF16-30-01-11 accepts a wide-range coil voltage of 24–60 V AC (50\/60 Hz) and 20–60 V DC, enabling flexible integration across global installations. Compact at 45 mm × 86 mm × 77 mm and weighing just 0.27 kg, this ABB AF Series contactor suits space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF16-30-01-11\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBL177001R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Contactor, AC Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–60 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 86 mm × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3471523110717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking for EU market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories listed for North American safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCQC:\u003c\/strong\u003e China Quality Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e American Bureau of Shipping type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBV:\u003c\/strong\u003e Bureau Veritas type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40:\u003c\/strong\u003e UL standard for air-conditioning and heat pump equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e UL listing for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1:\u003c\/strong\u003e UL standard for electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40:\u003c\/strong\u003e Canadian standard for HVAC\/heat pump equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335-2-40 LZGH2 A2L:\u003c\/strong\u003e CSA listing for A2L refrigerant applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947-4-1:\u003c\/strong\u003e Canadian standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60335:\u003c\/strong\u003e Canadian standard series for household and similar apparatus\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 60947:\u003c\/strong\u003e Canadian standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1 \/ EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-4 \/ EN 60947-4:\u003c\/strong\u003e Contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Combined IEC\/EN general rules for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Combined IEC\/EN standard for contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-4:\u003c\/strong\u003e IEC standard for contactors and motor starters (consolidated reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-5:\u003c\/strong\u003e IEC standard for control circuit devices (consolidated reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60715:\u003c\/strong\u003e Dimensions for DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60529 \/ EN60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear (consolidated reference)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60068-2-27:\u003c\/strong\u003e Environmental testing — shock\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the energy efficiency of networked standby\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN45555-92:\u003c\/strong\u003e Supplementary standard for energy efficiency assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229136589083,"sku":"1SBL177001R1101","price":25.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sbl177001r1101-af16-30-01-11-contactor-ac-switching_c3c61cd1-7966-4697-9593-2fbda247eb1c.webp?v=1777156825"}],"url":"https:\/\/stoklink.com\/collections\/power-contactors.oembed?page=33","provider":"Stoklink","version":"1.0","type":"link"}