{"title":"PLC CPUs, Safety PLCs \u0026 Logic Modules","description":"\u003cp\u003ePLC CPUs, safety PLCs and logic modules from Siemens, Schneider Electric and ABB. The range has over 240 controllers, from small logic relays such as LOGO! 8 and Zelio Logic to SIMATIC S7-1500 and redundant S7-400H systems. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSIMATIC S7-1500 and S7-1500F CPUs, including fail-safe and technology versions.\u003c\/li\u003e\n\u003cli\u003eSIMATIC S7-1200 and S7-400 CPUs, including S7-400H redundant systems.\u003c\/li\u003e\n\u003cli\u003eModicon M221, M241 and M262 controllers from Schneider Electric.\u003c\/li\u003e\n\u003cli\u003eLogic modules: LOGO! 8 and Zelio Logic for small machines and building control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProgram memory and cycle time: size them to the control task and expected growth.\u003c\/li\u003e\n\u003cli\u003eOnboard I\/O and expansion: small controllers have fixed I\/O, larger CPUs scale through modules.\u003c\/li\u003e\n\u003cli\u003eInterfaces: check PROFINET, Ethernet, serial and OPC UA support against the plant network.\u003c\/li\u003e\n\u003cli\u003eSafety rating: a safety PLC must match the SIL required by the risk assessment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I replace an S7-300 CPU with an S7-1500?\u003c\/h3\u003e\n\u003cp\u003eNot as a direct swap. The hardware differs and the program must be migrated in TIA Portal. Plan for new I\/O or an interface module.\u003c\/p\u003e\n\u003ch3\u003eWhat does the F in S7-1500F mean?\u003c\/h3\u003e\n\u003cp\u003eIt marks a fail-safe CPU. It runs safety functions alongside the standard program and needs F-rated I\/O for safety signals.\u003c\/p\u003e\n\u003ch3\u003eDo you ship CPUs outside Turkey?\u003c\/h3\u003e\n\u003cp\u003eStoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"schneider-electric-tm221c16r-modicon-m221-plc","title":"Schneider Electric TM221C16R Modicon M221 16 I\/O 9DI 7DO Relay Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C16R is a Modicon M221 logic controller with 16 discrete I\/O - 9 discrete inputs and 7 relay outputs rated 2 A - running from a 100-240 V AC supply. It provides 2 analog inputs, 4 fast counting inputs, and USB plus RS232\/RS485 serial ports for hardwired machine control panels programmed in SoMachine Basic.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221C16R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648694\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0-10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 local \/ 11 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS485), Serial 2 (RJ45, RS232\/RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII (serial), USB (SoMachine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.346 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degC horizontal \/ -10 to 35 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C16R's 7 relay outputs (5-125 V DC or 5-250 V AC, 2 A each) switch AC loads such as contactor coils or pilot lights directly, without an external interposing relay - the transistor-output C16T switches only 24 V DC loads but reaches PWM\/PLS output rates up to 100 kHz that this relay variant cannot match, since relay switching frequency here caps at 20 operations per minute at full load. Local I\/O tops out at 9 DI \/ 7 DO; machines needing more points step up to the 24 I\/O C24R or scale through the 4 local \/ 11 remote expansion module slots rather than moving to a larger base unit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eHardwired relay-logic machine control panels - conveyor and packaging line control, small-machine automation, and panels switching contactor coils or 230 V pilot devices directly from the controller.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230609871131,"sku":"TM221C16R","price":221.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c16r-modicon-m221-plc.jpg?v=1790279834"},{"product_id":"schneider-electric-tm221c16t-modicon-m221-plc","title":"Schneider Electric TM221C16T Modicon M221 16 I\/O 9DI 7DO Transistor PNP Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C16T is a Modicon M221 logic controller with 16 discrete I\/O - 9 discrete inputs (4 fast) and 7 PNP transistor outputs (2 fast) rated 0.5 A - running from a 24 V DC supply. Fast outputs reach 100 kHz PWM\/PLS for pulse-train positioning, alongside USB and RS232\/RS485 serial ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221C16T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 discrete + 4 fast (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 transistor + 2 fast, PNP (positive logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0-10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 local \/ 11 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS485), Serial 2 (RJ45, RS232\/RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII (serial), USB (SoMachine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.346 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degC horizontal \/ -10 to 35 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C16T's PNP transistor outputs switch 24 V DC loads at up to 100 kHz on outputs Q0-Q1 (PTO\/PWM\/PLS modes), which the relay-output C16R cannot do since its relays cap at 20 operations per minute - pick this variant for stepper or pulse-train positioning axes, and the C16R instead when the panel needs to switch 230 V AC loads directly without external relays. Local I\/O is the same 9 DI \/ 7 DO as the C16R; step up to the 24 I\/O C24T once the panel needs more points, or add expansion modules (4 local \/ 11 remote) rather than move to a larger base unit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eHardwired 24 V DC machine control panels needing pulse-train or PWM outputs - stepper-driven positioning axes, frequency generation, and small-machine automation on a 24 V DC control supply.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230609936667,"sku":"TM221C16T","price":221.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c16t-modicon-m221-plc.jpg?v=1790279842"},{"product_id":"schneider-electric-tm221c24r-modicon-m221-plc","title":"Schneider Electric TM221C24R Modicon M221 24 I\/O 14DI 10DO Relay Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C24R is a Modicon M221 logic controller with 24 discrete I\/O - 14 discrete inputs and 10 relay outputs rated 2 A - running from a 100-240 V AC supply. It provides 2 analog inputs, 4 fast counting inputs, and USB plus RS232\/RS485 serial ports for hardwired machine control panels programmed in SoMachine Basic.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221C24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0-10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS485), Serial 2 (RJ45, RS232\/RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII (serial), USB (SoMachine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.395 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degC horizontal \/ -10 to 35 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C24R steps up from the 16 I\/O C16R to 14 DI \/ 10 relay DO when a panel outgrows 16 points, without moving to a larger CPU family - the relay outputs (5-125 V DC or 5-250 V AC, 2 A each) still switch AC contactor coils and pilot devices directly. It also gains more expansion headroom (7 local \/ 14 remote modules versus 4\/11 on the C16R), useful when the panel needs distributed remote I\/O beyond the base unit. Where fast pulse-train outputs are needed instead of relay switching, the transistor-output C24T covers the same 24-point count.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMid-size hardwired relay-logic panels - packaging, conveyor, and material-handling machines needing more than 16 but fewer than 40 I\/O points, switching AC loads directly.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230610067739,"sku":"TM221C24R","price":284.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c24r-modicon-m221-plc.jpg?v=1790279852"},{"product_id":"schneider-electric-tm221c24t-modicon-m221-plc","title":"Schneider Electric TM221C24T Modicon M221 24 I\/O 14DI 10DO Transistor PNP Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C24T is a Modicon M221 logic controller with 24 discrete I\/O - 14 discrete inputs (4 fast) and 10 PNP transistor outputs (2 fast) rated 0.5 A - running from a 24 V DC supply. Fast outputs reach 100 kHz PWM\/PLS for pulse-train positioning, alongside USB and RS232\/RS485 serial ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221C24T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 discrete + 4 fast (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 transistor + 2 fast, PNP (positive logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0-10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS485), Serial 2 (RJ45, RS232\/RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII (serial), USB (SoMachine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.395 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degC horizontal \/ -10 to 35 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C24T steps up from the 16 I\/O C16T to 14 DI \/ 10 transistor DO for panels needing more pulse-train or high-speed digital points - fast outputs Q0-Q1 still reach 100 kHz for PTO\/PWM\/PLS motion functions, the same as the smaller C16T. Expansion headroom grows to 7 local \/ 14 remote modules versus 4\/11 on the C16T. Where the panel switches AC loads instead of 24 V DC, the relay-output C24R covers the same 24-point count without needing interposing relays.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMid-size 24 V DC panels needing pulse-train or high-speed outputs - stepper positioning, frequency generation, and machine control between 16 and 40 I\/O points.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230610133275,"sku":"TM221C24T","price":284.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c24t-modicon-m221-plc.jpg?v=1790279859"},{"product_id":"schneider-electric-tm221c40r-modicon-m221-plc","title":"Schneider Electric TM221C40R Modicon M221 40 I\/O 24DI 16DO Relay Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C40R is the largest-I\/O Modicon M221 logic controller in the relay family, with 40 discrete I\/O - 24 discrete inputs and 16 relay outputs rated 2 A - running from a 100-240 V AC supply. It provides 2 analog inputs, 4 fast counting inputs, and USB plus RS232\/RS485 serial ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221C40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648731\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0-10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS485), Serial 2 (RJ45, RS232\/RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII (serial), USB (SoMachine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.456 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degC horizontal \/ -10 to 35 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C40R is the top of the relay-output M221 range, stepping up from the 24 I\/O C24R when a hardwired panel needs 24 DI \/ 16 relay DO on a single base unit rather than adding expansion modules. It shares the same 7 local \/ 14 remote expansion capacity as the C24R, so the extra headroom comes from the base unit's I\/O count, not more expansion slots. As with the smaller relay variants, each output switches AC contactor coils or pilot devices directly, at the cost of the 100 kHz pulse-train outputs only the transistor-output variants provide.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLarge hardwired relay-logic panels - multi-zone conveyor systems, packaging lines, and machine control panels needing 40 discrete points switching AC loads directly on one base controller.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230610952475,"sku":"TM221C40R","price":370.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c40r-modicon-m221-plc.jpg?v=1790279866"},{"product_id":"schneider-electric-tm221c40t-modicon-m221-plc","title":"Schneider Electric TM221C40T Modicon M221 40 I\/O 24V DC Transistor Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221C40T is a Modicon M221 logic controller with 40 discrete I\/O — 24 inputs (4 fast) and 16 transistor outputs (2 fast) — powered from 24 V DC. It switches up to 0.5 A per output, supports up to 7 local expansion modules, and integrates USB, RS485 and RS232\/RS485 serial ports for Modbus master\/slave communication.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221C40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 4 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.1 W without expansion, 16 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS485 (RJ45), RS232\/RS485 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032\/CR2032 lithium, 1 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 degrees C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e160 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.456 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221C40T's 16 transistor outputs switch at up to 100 kHz on Q0-Q1 (PTO\/PWM\/PLS), the fastest output stage in the M221 range — pick it over a relay-output sibling when the application needs pulse-train motion outputs (2 axes up to 100 kHz) rather than switching AC loads directly. With 24 inputs (4 of them 100 kHz fast counters) it fits medium machines needing more I\/O density than the smaller 16 or 24-point models without moving to a rack-based M241.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230613737755,"sku":"TM221C40T","price":370.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221c40t-modicon-m221-plc.jpg?v=1790280440"},{"product_id":"schneider-electric-tm221ce16r-modicon-m221-plc","title":"Schneider Electric TM221CE16R Modicon M221 16 I\/O 9DI 7DO Relay Ethernet Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221CE16R is a Modicon M221 logic controller with 16 discrete I\/O: 9 discrete inputs and 7 relay outputs rated 2 A, plus 2 analog inputs. It runs from a 100...240 V AC supply and integrates Ethernet, a non-isolated RS232\/RS485 serial port, and a USB programming port for hardwired machine control architectures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221CE16R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85...264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 (IEC 61131-2 Type 1, 24 V DC, sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (0...10 V, 10-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...125 V DC \/ 5...250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 local \/ 11 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB user application\/data RAM, 256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Counting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (HSC mode, 100 kHz, 32-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, Modbus RTU\/ASCII, EtherNet\/IP adapter, DHCP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35-15 \/ TH35-7.5 DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover in place)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.346 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10...55 °C horizontal \/ -10...35 °C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221CE16R's 7 relay outputs (5...125 V DC or 5...250 V AC, 2 A each) switch AC loads such as contactor coils or pilot lights directly, without an external interposing relay - a transistor-output M221 variant would need one for anything above 24 V DC. Built-in Ethernet with Modbus TCP and EtherNet\/IP adapter support puts it on a plant network without an added communication module, which a non-Ethernet M221 variant lacks. Local I\/O tops out at 16 points (9 DI, 7 DO); machines needing more scale through the 4 local or 11 remote expansion module slots rather than a larger base unit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to hardwired relay-logic machine control panels that need networked Ethernet access - conveyor and packaging line control, small-machine automation, and panels where SoMachine Basic programming replaces a wired relay logic scheme.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230613868827,"sku":"TM221CE16R","price":328.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce16r-modicon-m221-plc.jpg?v=1790189864"},{"product_id":"schneider-electric-tm221ce16t-modicon-m221-plc","title":"Schneider Electric TM221CE16T Modicon M221 16-IO 24V DC Transistor Ethernet PLC","description":"\u003cp\u003eThe Schneider Electric TM221CE16T is a Modicon M221 logic controller with 16 discrete I\/O — 9 inputs (4 fast) and 7 transistor outputs (2 fast) — plus 2 analog inputs, powered from 24 V DC. It integrates Ethernet, RS232\/RS485 serial, and USB ports, supports up to 4 local or 11 remote I\/O expansion modules, and carries an IP20 rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221CE16T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e9 (4 fast), 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Inputs\u003c\/td\u003e\n\u003ctd\u003e2, 0...10 V, 10-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e7 transistor (2 fast), 24 V DC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e4 local \/ 11 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤30 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast inputs (HSC mode), 100 kHz, 32-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server, Modbus TCP slave, Ethernet\/IP adapter, DHCP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e95 x 90 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.346 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10...55 °C (horizontal) \/ -10...35 °C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221CE16T's 9 DI \/ 7 DO transistor mix, including 4 fast inputs and 2 fast transistor outputs at up to 100 kHz, suits compact machines needing high-speed counting or pulse output without stepping up to the M241 platform. Its built-in Ethernet port and Modbus TCP\/Ethernet-IP services let it network directly without an add-on communication module, and the 4-module local expansion limit (11 remote) sets the ceiling before a larger M221 or M241 controller is needed.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCompact standalone machine control with Ethernet networking, high-speed counting, and PWM\/pulse-train output on small automation cells.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230613967131,"sku":"TM221CE16T","price":328.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce16t-modicon-m221-plc.jpg?v=1790284098"},{"product_id":"schneider-electric-tm221ce24r-modicon-m221-plc","title":"Schneider Electric TM221CE24R Modicon M221 TM221C 24 IO Ethernet Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221CE24R is a Modicon M221 logic controller with 24 discrete I\/O (14 inputs, 10 relay outputs), built-in Ethernet, USB and RS232\/RS485 serial ports. It runs from a 100-240 V AC supply, switches loads up to 2 A per relay output, and provides 256 kB of application memory with an optional SD card slot.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM221CE24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated supply voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14, 24 V DC, sink or source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, 0...10 V, 10-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete output voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...125 V DC \/ 5...250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete output current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal discrete I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O expansion modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (mini B), RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP server\/client, Modbus RTU\/ASCII, Ethernet\/IP adapter, DHCP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 256 kB flash backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-time clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounting inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 fast inputs, HSC mode, 100 kHz, 32-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail or plate\/panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 with protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10...55 C horizontal \/ -10...35 C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 110 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.395 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 14 discrete inputs and 10 relay outputs give 24 total I\/O without an expansion module, while the base still accepts up to 7 local expansion modules when more I\/O is needed. Relay outputs switch up to 2 A at 5-250 V AC or 5-125 V DC, useful for mixed AC\/DC field loads that a transistor-output controller cannot switch directly. Built-in Ethernet plus RS232\/RS485 lets the controller run Modbus TCP alongside a serial link to existing equipment without an added communication module. The 2 GB SD card slot and 256 kB flash backup support local data logging or recipe storage beyond the onboard application memory.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230614458651,"sku":"TM221CE24R","price":410.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce24r-modicon-m221-plc.jpg?v=1790287411"},{"product_id":"schneider-electric-tm221ce24t-modicon-m221-plc","title":"Schneider Electric TM221CE24T Modicon M221 24 I\/O Ethernet Transistor Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221CE24T is a Modicon M221 logic controller with 24 discrete I\/O — 14 inputs (4 fast) and 10 transistor outputs (2 fast) — supplied from 24 V DC. It adds an integrated Ethernet RJ45 port (Modbus TCP client\/server, EtherNet\/IP adapter) alongside USB and RS232\/RS485 serial, switching up to 0.5 A per output channel.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221CE24T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e14 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e10 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 5 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.8 W without expansion, 14 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, up to 100 m copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server\/slave, EtherNet\/IP adapter, DHCP client, Modbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032\/CR2032 lithium, 1 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e110 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.395 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the TM221CE24T over a non-Ethernet M221 when the machine needs native Modbus TCP or EtherNet\/IP connectivity without an add-on gateway — the built-in 10\/100 Mbit RJ45 port also handles the DHCP client and TCP server\/client roles needed for SCADA polling. At 24 I\/O (14 DI\/10 DO) it sits below the 40-point models, so use it for compact machines where two fast outputs (100 kHz PTO\/PLS) are enough for a single-axis positioning task.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230614688027,"sku":"TM221CE24T","price":410.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce24t-modicon-m221-plc.jpg?v=1790280446"},{"product_id":"schneider-electric-tm221ce40r-modicon-m221-plc","title":"Schneider Electric TM221CE40R Modicon M221 40-IO Relay Ethernet Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221CE40R is a Modicon M221 logic controller with 40 discrete I\/O — 24 inputs and 16 relay outputs (2 A, 5-250 V AC or 5-125 V DC) — plus 2 analog inputs, powered from 100-240 V AC. It integrates Ethernet, RS232\/RS485 serial, and USB ports, and supports up to 7 local or 14 remote I\/O expansion modules.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221CE40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648793\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85...264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Inputs\u003c\/td\u003e\n\u003ctd\u003e2, 0...10 V, 10-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 relay (normally open), 2 A, 5...125 V DC \/ 5...250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e256 kB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤30 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast inputs (HSC mode), 100 kHz, 32-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eDHCP client, Modbus TCP client\/server, Modbus TCP slave, Ethernet\/IP adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e160 x 90 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.456 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10...55 °C (horizontal) \/ -10...35 °C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 16-relay output block (2 A per point, 5-250 V AC or 5-125 V DC) lets the TM221CE40R switch mixed AC and DC loads directly — pilot lights, small AC contactor coils, 24 V DC valves — without external interposing relays, unlike a transistor-output M221 limited to DC loads. Its 100-240 V AC universal supply and built-in 24 V DC 250 mA sensor supply also remove the need for a separate control-power supply on a 40-point panel.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMixed AC\/DC discrete load switching on machine or panel control where a universal 100-240 V AC supply and integrated Ethernet networking are needed.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615179547,"sku":"TM221CE40R","price":535.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce40r-modicon-m221-plc.jpg?v=1790284105"},{"product_id":"schneider-electric-tm221ce40t-modicon-m221-plc","title":"Schneider Electric TM221CE40T Modicon M221 40 I\/O Ethernet Transistor Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221CE40T is a Modicon M221 logic controller with 40 discrete I\/O — 24 inputs (4 fast) and 16 transistor outputs (2 fast) — supplied from 24 V DC. Built-in Ethernet RJ45 (Modbus TCP client\/server, EtherNet\/IP adapter) joins USB and RS232\/RS485 serial ports, and each output switches up to 0.5 A with up to 7 local expansion modules supported.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221CE40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648809\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 4 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.9 W without expansion, 17 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, up to 100 m copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server\/slave, EtherNet\/IP adapter, DHCP client, Modbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032\/CR2032 lithium, 1 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e160 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.456 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221CE40T pairs the M221's largest compact I\/O count (40 points) with native Ethernet, so pick it over the non-Ethernet 40 I\/O model when the line needs Modbus TCP or EtherNet\/IP reporting without a separate gateway module. Its two 100 kHz fast outputs (Q0-Q1) still support PTO\/PWM\/PLS for basic motion, while the remaining transistor outputs handle discrete switching at up to 4 A per common.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615572763,"sku":"TM221CE40T","price":535.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221ce40t-modicon-m221-plc.jpg?v=1790280453"},{"product_id":"schneider-electric-tm221m16r-modicon-m221-book-plc","title":"Schneider Electric TM221M16R Modicon M221 Book 16 I\/O Relay Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221M16R is a Modicon M221 Book-format logic controller with 16 discrete I\/O — 8 inputs and 8 relay outputs — in a compact 70 x 70 x 90 mm housing. Supplied from 24 V DC, its normally-open relay outputs switch 5-125 V DC or 5-250 V AC at up to 2 A per point, ideal for mixed AC\/DC load switching.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221M16R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point, 7 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e3.6 W without expansion, 22.5 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 operations\/minute at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS485 (RJ45), RS232\/RS485 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032\/CR2032 lithium, 1 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221M16R's relay outputs handle both AC and DC loads directly (5-250 V AC or 5-125 V DC), so choose it over a transistor-output Book controller when the application switches contactor coils, solenoid valves, or indicator lamps at line voltage without an external interposing relay. Its 20 operations\/minute maximum switching frequency at full load is a hard limit — high-cycle-rate outputs belong on a transistor variant instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615703835,"sku":"TM221M16R","price":221.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221m16r-modicon-m221-book-plc.jpg?v=1790280460"},{"product_id":"schneider-electric-tm221m16t-modicon-m221-book-plc","title":"Schneider Electric TM221M16T Modicon M221 Book 16 I\/O Transistor Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221M16T is a Modicon M221 Book-format logic controller with 16 discrete I\/O — 8 inputs (4 fast) and 8 PNP transistor outputs (2 fast) — in a compact 70 x 70 x 90 mm housing. Supplied from 24 V DC, it switches up to 0.5 A per output and supports PTO pulse-train outputs up to 100 kHz for simple positioning tasks.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221M16T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 4 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e3.2 W without expansion, 22 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS485 (RJ45), RS232\/RS485 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032\/CR2032 lithium, 1 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221M16T's PNP transistor outputs switch fast enough (up to 100 kHz on Q0-Q1 in PTO\/PWM\/PLS mode) for basic single-axis positioning, which the relay-output Book variant cannot do. Its 0.5 A per-channel rating suits PLC-driven solenoids and 24 V indicator loads rather than line-voltage switching, where the relay-output model is the better fit. The four fast inputs (I0, I1, I6, I7) respond in 5 microseconds, fast enough to catch a high-speed counter pulse or an encoder edge that a standard 35-microsecond input channel would miss.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615769371,"sku":"TM221M16T","price":221.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221m16t-modicon-m221-book-plc.jpg?v=1790280467"},{"product_id":"schneider-electric-tm221m32tk-modicon-m221-book-plc","title":"Schneider Electric TM221M32TK Modicon M221 Book 32 I\/O Transistor Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221M32TK is a Modicon M221 Book-format logic controller with 32 discrete I\/O — 16 inputs (4 fast) and 16 PNP transistor outputs (2 fast) — wired through HE-10 connectors in a 70 x 70 x 90 mm housing. Supplied from 24 V DC, each output switches 0.1 A (1.6 A per common), suited to dense low-current point counts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221M32TK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per point, 1.6 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W without expansion, 22.3 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connectors\u003c\/td\u003e\n\u003ctd\u003eHE-10, 20-pin for inputs, 20-pin for outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS485 (RJ45), RS232\/RS485 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221M32TK doubles the Book controller's I\/O count to 32 points through HE-10 connectors instead of the 16-point models' screw terminals, which suits panel builders using pre-wired ribbon-cable harnesses. Its lower 0.1 A per-channel and 1.6 A per-common output rating reflects the higher channel density — it fits many low-current 24 V DC loads (PLC inputs, small relays) rather than a handful of higher-draw actuators.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615900443,"sku":"TM221M32TK","price":328.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221m32tk-modicon-m221-book-plc.jpg?v=1790280477"},{"product_id":"schneider-electric-tm221me16r-modicon-m221-book-plc","title":"Schneider Electric TM221ME16R Modicon M221 Book 16 I\/O Relay Ethernet Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221ME16R is a Modicon M221 Book-format logic controller with 16 discrete I\/O — 8 inputs and 8 relay outputs — plus a built-in Ethernet RJ45 port for Modbus TCP and EtherNet\/IP. Supplied from 24 V DC, its normally-open relay outputs switch 5-125 V DC or 5-250 V AC at up to 2 A per point in a 70 x 70 x 90 mm housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221ME16R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point, 7 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.3 W without expansion, 23.3 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 operations\/minute at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, up to 100 m copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server\/slave, EtherNet\/IP adapter, DHCP client, Modbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221ME16R combines the 16-point relay Book controller with native Ethernet, so pick it over the serial-only relay variant when SCADA or line-level Modbus TCP polling is needed alongside line-voltage relay switching (5-250 V AC or 5-125 V DC, up to 2 A). Its EtherNet\/IP adapter role also lets an upstream PLC-class controller monitor the machine without protocol-conversion hardware.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230615965979,"sku":"TM221ME16R","price":323.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221me16r-modicon-m221-book-plc.jpg?v=1790280485"},{"product_id":"schneider-electric-tm221me16t-modicon-m221-book-plc","title":"Schneider Electric TM221ME16T Modicon M221 Book 16 I\/O Transistor Ethernet Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221ME16T is a Modicon M221 Book-format logic controller with 16 discrete I\/O — 8 inputs (4 fast) and 8 PNP transistor outputs (2 fast) — plus a built-in Ethernet RJ45 port for Modbus TCP and EtherNet\/IP. Supplied from 24 V DC in a 70 x 70 x 90 mm housing, it switches up to 0.5 A per output.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221ME16T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e8 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 4 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W without expansion, 22.9 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, up to 100 m copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server\/slave, EtherNet\/IP adapter, DHCP client, Modbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 2 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221ME16T adds Ethernet (Modbus TCP, EtherNet\/IP) to the 16-point transistor Book controller, making it the choice over the serial-only transistor variant when the machine needs network-level diagnostics or SCADA integration. Its two 100 kHz fast outputs still support PTO\/PWM\/PLS for simple positioning, unaffected by the added network interface. The DHCP client lets it pick up an IP address automatically on commissioning, which simplifies swapping a controller in the field without a static-address reconfiguration step.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230616031515,"sku":"TM221ME16T","price":323.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221me16t-modicon-m221-book-plc.jpg?v=1790280492"},{"product_id":"schneider-electric-tm221me32tk-modicon-m221-book-plc","title":"Schneider Electric TM221ME32TK Modicon M221 Book 32 I\/O Transistor Ethernet Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM221ME32TK is a Modicon M221 Book-format logic controller with 32 discrete I\/O — 16 inputs (4 fast) and 16 PNP transistor outputs (2 fast) — wired through HE-10 connectors, plus a built-in Ethernet RJ45 port for Modbus TCP and EtherNet\/IP. Supplied from 24 V DC, each output switches 0.1 A (1.6 A per common).\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM221ME32TK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (4 fast, HSC up to 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor (2 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per point, 1.6 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.2 W without expansion, 23.2 W with max expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connectors\u003c\/td\u003e\n\u003ctd\u003eHE-10, 20-pin for inputs, 20-pin for outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, up to 100 m copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP client\/server\/slave, EtherNet\/IP adapter, DHCP client, Modbus RTU\/ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e2x PTO pulse\/direction or CW\/CCW, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e256 kB application\/data RAM, 10,000 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e70 x 70 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus HazLoc\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM221ME32TK pairs the 32-point HE-10 transistor Book controller with built-in Ethernet, so choose it over the serial-only 32 I\/O variant when dense-channel machines also need Modbus TCP or EtherNet\/IP reporting. Each output's 0.1 A rating (1.6 A per common) still fits the same low-current 24 V DC loads the non-Ethernet model targets. The DHCP client lets it pick up an IP address automatically on commissioning, which simplifies swapping a controller in the field without a static-address reconfiguration step.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230616162587,"sku":"TM221ME32TK","price":441.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm221me32tk-modicon-m221-book-plc.jpg?v=1790280499"},{"product_id":"schneider-electric-tm241c24r-modicon-m241-plc","title":"Schneider Electric TM241C24R Modicon M241 24 I\/O Relay 100-240V AC Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241C24R is a Modicon M241 logic controller with 24 discrete I\/O — 14 inputs (8 fast) and a mixed 6-relay\/4-transistor (4 fast) output stage — supplied from 100-240 V AC. Relay outputs switch up to 2 A at 5-250 V AC or 5-125 V DC, and the controller supports up to 14 remote I\/O expansion modules for machines needing both discrete switching and AC-mains simplicity.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241C24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648816\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (85-264 V, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast, HSC up to 200 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e6 relay (normally open) + 4 transistor (4 fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Voltage\/Current\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC or 5-250 V AC, 2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Output Voltage\/Current\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 0.5 A per point \/ 0.1 A fast output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e4x PTO, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), RS485 (removable screw terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e8 MB program, 64 MB system memory RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash (backup of user programs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 16 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 2 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e150 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241C24R's relay outputs (6 of the 10, switching 5-250 V AC or 5-125 V DC at up to 2 A) let it drive AC contactors and solenoids directly from an AC-mains supply, unlike a transistor-only M241 that needs a 24 V DC source. Its remaining 4 transistor fast outputs (100 kHz PTO) cover a single positioning axis when the rest of the machine runs on relay-switched AC loads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230616228123,"sku":"TM241C24R","price":501.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241c24r-modicon-m241-plc.jpg?v=1790280507"},{"product_id":"schneider-electric-tm241c24t-modicon-m241-plc","title":"Schneider Electric TM241C24T Modicon M241 24 I\/O Transistor 24V DC Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241C24T is a Modicon M241 logic controller with 24 discrete I\/O — 14 inputs (8 fast) and 10 PNP transistor outputs (4 fast) — supplied from 24 V DC. Each standard output switches up to 0.5 A, fast outputs support PTO\/PWM\/PLS up to 100 kHz for 4 axes of pulse-train motion, and the controller accepts up to 14 remote I\/O expansion modules.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241C24T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611179\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast, HSC up to 200 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e10 transistor (4 fast), PNP positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point (Q0-Q9), 0.1 A fast output (Q0-Q3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e32.6-40.4 W with max expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e4x PTO, 100 kHz; 4x PTO transistor output, 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), RS485 (removable screw terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e8 MB program, 64 MB system memory RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash (backup of user programs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 16 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 2 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e150 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241C24T's all-transistor output stage (10 standard + 4 fast, up to 100 kHz PTO\/PWM\/PLS) supports up to 4 axes of pulse-train motion, which the relay-output M241 variant cannot do — pick it for machines needing multi-axis positioning rather than AC-load switching. Running from 24 V DC instead of the AC-supplied model also suits panels already standardized on a 24 V DC bus.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230616686875,"sku":"TM241C24T","price":501.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241c24t-modicon-m241-plc.jpg?v=1790280514"},{"product_id":"schneider-electric-tm241c40r-modicon-m241-plc","title":"Schneider Electric TM241C40R Modicon M241 40 I\/O Relay 100-240V AC Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241C40R is a Modicon M241 logic controller with 40 discrete I\/O — 24 inputs (8 fast) and a mixed 12-relay\/4-transistor (4 fast) output stage — supplied from 100-240 V AC. Relay outputs switch up to 2 A at 5-250 V AC or 5-125 V DC, giving the highest I\/O count in the M241 compact range for machines mixing AC field devices with fast-output motion.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241C40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (85-264 V, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 (8 fast, HSC up to 200 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e12 relay (normally open) + 4 transistor (4 fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Voltage\/Current\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC or 5-250 V AC, 2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Output Voltage\/Current\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 0.5 A per point \/ 0.1 A fast output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Total\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003e4x PTO, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B, RS232\/RS485 (RJ45), RS485 (removable screw terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e8 MB program, 64 MB system memory RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash (backup of user programs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Support\u003c\/td\u003e\n\u003ctd\u003eUp to 16 GB (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 2 year backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 with cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e190 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241C40R scales the M241's relay\/transistor mix to 40 I\/O, giving 12 relay outputs (5-250 V AC or 5-125 V DC, up to 2 A) for direct AC-load switching alongside 4 fast transistor outputs for a single positioning axis — pick it over the 24 I\/O relay model when the machine has more discrete AC loads (valves, contactors, lamps) than fast-output axes.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617014555,"sku":"TM241C40R","price":632.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241c40r-modicon-m241-plc.jpg?v=1790280521"},{"product_id":"schneider-electric-tm241c40t-modicon-m241-plc","title":"Schneider Electric TM241C40T Modicon M241 40 I\/O 24DI 16DO Transistor PNP Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241C40T is a Modicon M241 logic controller with 40 discrete I\/O - 24 inputs (8 fast) and 16 PNP transistor outputs (4 fast) - running from a 24 V DC supply. It provides USB, RS232\/RS485, and a second RS485 serial port for compact machine control programmed in EcoStruxure Machine Expert.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM241C40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480611186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 (8 fast, IEC 61131-2 Type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 transistor (4 fast), PNP (source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (transistor), 0.1 A (fast\/PTO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax I\/O Expansion Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM, 128 MB built-in flash (user program backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS232\/RS485), Serial 2 (removable terminal block, RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePositioning Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTO, 4 channels, up to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounting Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 fast (HSC, 200 kHz), 16 standard (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail TH35 or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10-50 degC (vertical), -10-55 degC (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241C40T's 40-point I\/O count (24 DI \/ 16 DO) and PNP transistor outputs suit compact machines needing more onboard I\/O than smaller M241 base units provide without adding expansion modules, while still leaving 7 local expansion slots for further growth. Its 4 fast inputs (200 kHz HSC) and 4 fast transistor outputs (100 kHz PTO\/PLS) support closed-loop positioning on up to 4 axes directly from the base unit, which relay-output M241 variants cannot match at the same speed. Marine specification certification (LR, ABS, DNV, GL) makes it a fit for shipboard control panels needing that class approval.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCompact-machine automation requiring integrated speed and position control - packaging, material handling, and general machine-control panels using DIN-rail mounting and EcoStruxure Machine Expert programming.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617080091,"sku":"TM241C40T","price":632.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241c40t-modicon-m241-plc.jpg?v=1790281435"},{"product_id":"schneider-electric-tm241ce24r-modicon-m241-plc","title":"Schneider Electric TM241CE24R Modicon M241 24 I\/O 14DI 6DO Relay Ethernet Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241CE24R is a Modicon M241 logic controller with 24 discrete I\/O - 14 inputs (8 fast) and 6 relay outputs plus 4 transistor outputs (4 fast) - running from a 100-240 V AC supply. It adds an embedded Ethernet port for Modbus TCP and EtherNet\/IP alongside USB and dual RS232\/RS485 serial ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM241CE24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480648830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast, IEC 61131-2 Type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 relay + 4 transistor (4 fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-125 V DC \/ 5-250 V AC (relay), 24 V DC (transistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A (relay), 0.5 A (transistor), 0.1 A (fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP, FTP, web server (WebVisu), OPC UA server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM, 128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS232\/RS485), Serial 2 (RS485), Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail TH35 or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10-50 degC (vertical), -10-55 degC (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241CE24R's embedded Ethernet port adds Modbus TCP, EtherNet\/IP, FTP, and OPC UA server connectivity that transistor-only, non-Ethernet M241 base units lack, making it the base unit of choice where the controller needs to sit on a plant network rather than communicate over serial links alone. Its 6 relay outputs (2 A, up to 250 V AC) switch contactor coils and pilot loads directly without an interposing relay, while the 4 transistor outputs (4 fast, 100 kHz PLS) still support basic pulse-train positioning where the relay outputs cannot. The 100-240 V AC supply removes the need for a separate 24 V DC power supply in panels already running on line voltage.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCompact-machine automation needing plant-network connectivity - packaging, material handling, and machine-control panels running Modbus TCP or EtherNet\/IP alongside relay-driven contactor and pilot-device switching.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617243931,"sku":"TM241CE24R","price":539.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241ce24r-modicon-m241-plc.jpg?v=1790281443"},{"product_id":"schneider-electric-tm241ce24t-modicon-m241-plc","title":"Schneider Electric TM241CE24T Modicon M241 24-IO 24V DC Transistor Ethernet PLC","description":"\u003cp\u003eThe Schneider Electric TM241CE24T is a Modicon M241 logic controller with 24 discrete I\/O — 14 inputs (8 fast) and 10 transistor outputs (4 fast) — powered from 24 V DC. It adds a second RS485 serial port to the M221's connectivity, runs on 64 MB system memory with a 128 MB flash backup, and supports up to a 16 GB SD card.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241CE24T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast), 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e10 transistor (4 fast), 24 V DC, 0.5 A (0.1 A fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 4-year life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤60 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast (HSC mode, 200 kHz) + 14 standard (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003ePTO x4 (100 kHz), PTO x4 transistor output (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, 2x RS232\/RS485 serial, Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Services\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, Ethernet\/IP, OPC UA server, FTP, SQL client, web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e150 x 90 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10...50 °C (vertical) \/ -10...55 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine Specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241CE24T's second serial port (RS485 on a removable terminal block) and OPC UA\/SQL-client Ethernet services go beyond the M221's networking, making it the choice when a machine needs a second field-device link alongside Ethernet, or to push data to a database or SCADA historian directly from the controller. Its 8 fast inputs and 4 fast transistor outputs at up to 100 kHz PTO cover basic positioning tasks without a separate motion controller.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCompact machine control needing dual serial connectivity, OPC UA\/SQL reporting, and basic PTO-based positioning at speeds up to 100 kHz.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617342235,"sku":"TM241CE24T","price":539.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241ce24t-modicon-m241-plc.jpg?v=1790284112"},{"product_id":"schneider-electric-tm241ce40r-modicon-m241-plc","title":"Schneider Electric TM241CE40R Modicon M241 40-IO Relay Transistor Ethernet PLC","description":"\u003cp\u003eThe Schneider Electric TM241CE40R is a Modicon M241 logic controller with 40 discrete I\/O — 24 inputs (8 fast), 12 relay outputs (2 A), and 4 transistor outputs (4 fast, 0.5 A) — powered from 100-240 V AC. It runs on 64 MB system memory with a 128 MB flash backup and supports up to a 16 GB SD card.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241CE40R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85...264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 (8 fast), 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e12 relay (2 A, 5...125 V DC \/ 5...250 V AC) + 4 transistor (0.5 A, 4 fast at 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 4-year life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤60 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast (HSC mode, 200 kHz) + 14 standard (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003ePTO x4 (100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, 2x RS232\/RS485 serial, Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e190 x 90 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10...50 °C (vertical) \/ -10...55 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine Specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMixing 12 relay points (for AC or DC loads up to 250 V AC) with 4 fast transistor outputs, the TM241CE40R covers both general-purpose switching and 100 kHz positioning outputs on a single 40-point controller — unlike the all-transistor TM241CE40T, it can drive AC loads directly. Its 100-240 V AC universal supply plus a built-in 24 V DC 400 mA sensor supply cover a mixed-voltage panel without an add-on power supply module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMixed relay\/transistor discrete switching on a universal-voltage panel needing both general I\/O and limited high-speed positioning outputs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617473307,"sku":"TM241CE40R","price":669.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241ce40r-modicon-m241-plc.jpg?v=1790284118"},{"product_id":"schneider-electric-tm241ce40t-modicon-m241-plc","title":"Schneider Electric TM241CE40T Modicon M241 40-IO 24V DC Transistor Ethernet PLC","description":"\u003cp\u003eThe Schneider Electric TM241CE40T is a Modicon M241 logic controller with 40 discrete I\/O — 24 inputs (8 fast) and 16 transistor outputs (4 fast, 0.5 A) — powered from 24 V DC. It runs on 64 MB system memory with a 128 MB flash backup, supports up to a 16 GB SD card, and integrates dual serial ports plus Ethernet.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241CE40T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 (8 fast), 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor (4 fast), 24 V DC, 0.5 A (0.1 A fast)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 4-year life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤60 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast (HSC mode, 200 kHz) + 16 standard (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003ePTO x4 (100 kHz), PTO x4 transistor output (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, 2x RS232\/RS485 serial, Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e190 x 90 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10...50 °C (vertical) \/ -10...55 °C (horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine Specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAll 16 outputs on the TM241CE40T are transistor rather than relay, so it is the pick when every output drives 24 V DC loads — valves, indicator stacks, small DC contactors — rather than mixed-voltage or AC loads; for AC switching on the same 40-point count, use the TM241CE40R instead. Four of its outputs support 100 kHz PTO positioning, which the all-relay variant does not offer.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e24 V DC discrete switching with basic PTO-based positioning on compact machines needing 40 I\/O points at speeds up to 100 kHz.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617604379,"sku":"TM241CE40T","price":669.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241ce40t-modicon-m241-plc.jpg?v=1790284129"},{"product_id":"schneider-electric-tm241cec24r-modicon-m241-plc","title":"Schneider Electric TM241CEC24R Modicon M241 24-IO CANopen Relay Ethernet PLC","description":"\u003cp\u003eThe Schneider Electric TM241CEC24R is a Modicon M241 logic controller with 24 discrete I\/O — 14 inputs (8 fast), 6 relay outputs (2 A), and 4 transistor outputs (4 fast) — plus an integrated CANopen master port, powered from 100-240 V AC. It supports up to 63 CANopen server devices alongside Ethernet and dual RS232\/RS485 serial connectivity.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTM241CEC24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480648854\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e85...264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast), 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e6 relay (2 A, 5...125 V DC \/ 5...250 V AC) + 4 transistor (0.5 A, 4 fast at 0.1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e7 local \/ 14 remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Backup\u003c\/td\u003e\n\u003ctd\u003e128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eBR2032 lithium, 4-year life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd\u003eYes, drift ≤60 s\/month at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Inputs\u003c\/td\u003e\n\u003ctd\u003e4 fast (HSC mode, 200 kHz) + 14 standard (1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Functions\u003c\/td\u003e\n\u003ctd\u003ePTO x4 (100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Connections\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Mini-B, 2x RS232\/RS485 serial, Ethernet (RJ45), CANopen (SUB-D 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCANopen\u003c\/td\u003e\n\u003ctd\u003eMaster, up to 63 server devices, 20 kbit\/s-1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eTH35 DIN rail (15 or 7.5 mm) or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e150 x 90 x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine Specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241CEC24R adds a dedicated CANopen master port (up to 63 server devices) that the plain TM241CE24T\/CE40R do not have, making it the choice when the machine needs to poll CANopen drives or I\/O nodes alongside Ethernet and Modbus. Its mixed 6-relay \/ 4-transistor output block covers both AC\/DC switching and 100 kHz PTO positioning on the same 24-point controller.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachines integrating CANopen field devices (drives, remote I\/O) alongside Ethernet networking and mixed relay\/transistor discrete control.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617735451,"sku":"TM241CEC24R","price":597.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241cec24r-modicon-m241-plc.jpg?v=1790284136"},{"product_id":"schneider-electric-tm241cec24t-modicon-m241-plc","title":"Schneider Electric TM241CEC24T Modicon M241 24 I\/O Transistor Ethernet CANopen Programmable Logic Controller","description":"\u003cp\u003eThe Schneider Electric TM241CEC24T is a Modicon M241 logic controller with 24 discrete I\/O - 14 inputs (8 fast) and 10 PNP transistor outputs (4 fast) - running from a 24 V DC supply. It adds embedded Ethernet (Modbus TCP, EtherNet\/IP) and a CANopen master port alongside USB and dual RS232\/RS485 serial links.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM241CEC24T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480611117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon M241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLogic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Us] Rated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 (8 fast, IEC 61131-2 Type 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 transistor (4 fast), PNP (source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (transistor), 0.1 A (fast\/PTO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10BASE-T\/100BASE-TX, RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, EtherNet\/IP adapter, FTP, web server (WebVisu), OPC UA server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCANopen Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSUB-D 9, master, up to 1000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCANopen Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS 301 V4.02, DR 303-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB system RAM, 128 MB built-in flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=16 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB (Mini-B), Serial 1 (RJ45, RS232\/RS485), Serial 2 (RS485), Ethernet (RJ45), CANopen (SUB-D 9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail TH35 or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 x 95 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with protective cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eLR\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA 12-12-01\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2:2007\u003c\/li\u003e\n\u003cli\u003eMarine specification (LR, ABS, DNV, GL)\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM241CEC24T combines an embedded Ethernet port with a CANopen master port, so it fits machines needing both a plant-network connection (Modbus TCP, EtherNet\/IP) and a CANopen fieldbus for distributed drives or I\/O in the same controller. Its 10 PNP transistor outputs (4 fast, up to 100 kHz PLS) suit sinking-logic field wiring and basic pulse-train positioning, and the CANopen port runs up to 1000 kbit\/s over short distances or down to 20 kbit\/s over 2500 m, so network speed can be traded for cable run length as the machine layout requires.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCompact-machine automation combining plant-network connectivity and a CANopen fieldbus - multi-axis packaging or material-handling machines where distributed drives or remote I\/O communicate over CANopen while the controller reports to a plant SCADA or MES over Ethernet.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230617800987,"sku":"TM241CEC24T","price":597.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tm241cec24t-modicon-m241-plc.jpg?v=1790281450"},{"product_id":"siemens-s7-1200-cpu-1214c-6es7214-1ag40-0xb0","title":"Siemens S7-1200 CPU 1214C – 6ES7214-1AG40-0XB0","description":"\u003cp data-start=\"237\" data-end=\"718\"\u003eThe Siemens S7-1200 CPU 1214C is a compact and high-performance PLC designed for modern industrial automation applications. Offering reliable processing power, integrated PROFINET communication, and flexible I\/O capabilities, this CPU provides a scalable solution for machine control, factory automation, and small to mid-size process systems. With seamless integration into the TIA Portal software, it enables fast configuration, efficient programming, and simplified diagnostics.\u003c\/p\u003e\n\u003chr data-start=\"720\" data-end=\"723\"\u003e\n\u003ch2 data-start=\"725\" data-end=\"754\"\u003e\u003cstrong data-start=\"728\" data-end=\"754\"\u003eKey Technical Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"755\" data-end=\"1503\"\u003e\n\u003cli data-start=\"755\" data-end=\"779\"\u003e\n\u003cp data-start=\"757\" data-end=\"779\"\u003e\u003cstrong data-start=\"757\" data-end=\"767\"\u003eModel:\u003c\/strong\u003e CPU 1214C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"819\"\u003e\n\u003cp data-start=\"782\" data-end=\"819\"\u003e\u003cstrong data-start=\"782\" data-end=\"798\"\u003ePart Number:\u003c\/strong\u003e 6ES7214-1AG40-0XB0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"820\" data-end=\"901\"\u003e\n\u003cp data-start=\"822\" data-end=\"901\"\u003e\u003cstrong data-start=\"822\" data-end=\"848\"\u003eProcessor Performance:\u003c\/strong\u003e High-speed processing for machine-level automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"902\" data-end=\"1017\"\u003e\n\u003cp data-start=\"904\" data-end=\"926\"\u003e\u003cstrong data-start=\"904\" data-end=\"924\"\u003eIntegrated I\/Os:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"929\" data-end=\"1017\"\u003e\n\u003cli data-start=\"929\" data-end=\"954\"\u003e\n\u003cp data-start=\"931\" data-end=\"954\"\u003e\u003cstrong data-start=\"931\" data-end=\"952\"\u003e14 Digital Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"991\"\u003e\n\u003cp data-start=\"959\" data-end=\"991\"\u003e\u003cstrong data-start=\"959\" data-end=\"981\"\u003e10 Digital Outputs\u003c\/strong\u003e (relay)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"994\" data-end=\"1017\"\u003e\n\u003cp data-start=\"996\" data-end=\"1017\"\u003e\u003cstrong data-start=\"996\" data-end=\"1015\"\u003e2 Analog Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1156\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1050\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1048\"\u003eCommunication Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1053\" data-end=\"1156\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1104\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1104\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1070\"\u003e1× PROFINET\u003c\/strong\u003e (Integrated Ethernet interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1156\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1156\"\u003eSupports HMI and networked automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1157\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1159\" data-end=\"1172\"\u003e\u003cstrong data-start=\"1159\" data-end=\"1170\"\u003eMemory:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1175\" data-end=\"1234\"\u003e\n\u003cli data-start=\"1175\" data-end=\"1205\"\u003e\n\u003cp data-start=\"1177\" data-end=\"1205\"\u003e\u003cstrong data-start=\"1177\" data-end=\"1196\"\u003eProgram Memory:\u003c\/strong\u003e 100 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1226\"\u003eData Memory:\u003c\/strong\u003e 50 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1330\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1265\"\u003eSignal Module Expansion:\u003c\/strong\u003e Supports additional digital, analog, and communication modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1373\"\u003e\n\u003cp data-start=\"1333\" data-end=\"1373\"\u003e\u003cstrong data-start=\"1333\" data-end=\"1357\"\u003eHigh-Speed Counters:\u003c\/strong\u003e Up to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1403\"\u003e\n\u003cp data-start=\"1376\" data-end=\"1403\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1393\"\u003ePower Supply:\u003c\/strong\u003e 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1404\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1406\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1406\" data-end=\"1432\"\u003eOperating Temperature:\u003c\/strong\u003e –20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1503\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1477\"\u003eProgramming Software:\u003c\/strong\u003e TIA Portal (STEP 7 Basic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1505\" data-end=\"1508\"\u003e\n\u003ch2 data-start=\"1510\" data-end=\"1537\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1537\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1538\" data-end=\"1771\"\u003e\n\u003cli data-start=\"1538\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1540\" data-end=\"1578\"\u003eMachine automation and OEM equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1621\"\u003e\n\u003cp data-start=\"1581\" data-end=\"1621\"\u003eConveyor and material-handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1622\" data-end=\"1645\"\u003e\n\u003cp data-start=\"1624\" data-end=\"1645\"\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1678\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1678\"\u003eHVAC and building automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1681\" data-end=\"1731\"\u003eProcess monitoring and small-scale SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1771\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1771\"\u003eIndustrial panel and MCC integrations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1773\" data-end=\"1776\"\u003e\n\u003ch2 data-start=\"1778\" data-end=\"1803\"\u003e\u003cstrong data-start=\"1781\" data-end=\"1803\"\u003eProduct Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1804\" data-end=\"2156\"\u003e\n\u003cli data-start=\"1804\" data-end=\"1855\"\u003e\n\u003cp data-start=\"1806\" data-end=\"1855\"\u003eCompact design with high processing performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1913\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1913\"\u003eSeamless integration with Siemens TIA Portal platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"1980\"\u003e\n\u003cp data-start=\"1916\" data-end=\"1980\"\u003eIntegrated PROFINET for efficient communication and networking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1981\" data-end=\"2031\"\u003e\n\u003cp data-start=\"1983\" data-end=\"2031\"\u003eLong lifecycle and industry-proven reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2032\" data-end=\"2091\"\u003e\n\u003cp data-start=\"2034\" data-end=\"2091\"\u003eFlexible expansion with a wide range of S7-1200 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2094\" data-end=\"2156\"\u003eEasy diagnostics and maintenance through built-in web server\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":51420876898587,"sku":"6ES7214-1AG40-0XB0","price":350.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7214-1ag40-0xb0-cpu-1214c-dc-dc-dc-14di-10do-2ai-1214c-6es7214-1ag40-0xb0_470bc6cb-9758-4976-8f80-cbb055e7fc58.webp?v=1777185870"},{"product_id":"siemens-3rd1000-0ba00-0ep0-3rd1-2-0a-3p-204288v-programmable-logic-controller","title":"Siemens 3RD1000-0BA00-0EP0 3RD1 2.0A 3P 204288V Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 3RD1000-0BA00-0EP0 is a programmable logic controller from the SENTRON\/SIRIUS 3RD1 series. SIMATIC ET 200SP e-Starter 0.1 - 2.0 A reversing starter electronic short-circuit protection. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-0BA00-0EP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOf supplied fan unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FS00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOf the optionally available fan unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FD00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function external reset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the overcurrent release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETU\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable current limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithout load current share typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of calculation of power loss current-dependent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003equadratic\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.667 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RD1000-0BA00-0EP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RD1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620074123547,"sku":"3RD1000-0BA00-0EP0","price":851.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rd1000-0ba00-0ep0.webp?v=1784379788"},{"product_id":"siemens-3rd1000-0bb00-0ep0-3rd1-7-0a-3p-204288v-programmable-logic-controller","title":"Siemens 3RD1000-0BB00-0EP0 3RD1 7.0A 3P 204288V Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 3RD1000-0BB00-0EP0 is a programmable logic controller from the SENTRON\/SIRIUS 3RD1 series. SIMATIC ET 200SP e-Starter 0.7 - 7.0 A reversing starter electronic short-circuit protection. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-0BB00-0EP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOf supplied fan unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FS00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOf the optionally available fan unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FD00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function external reset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the overcurrent release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETU\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable current limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithout load current share typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of calculation of power loss current-dependent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003equadratic\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.655 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RD1000-0BB00-0EP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RD1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620074320155,"sku":"3RD1000-0BB00-0EP0","price":1085.19,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rd1000-0bb00-0ep0.webp?v=1784379794"},{"product_id":"siemens-3rd1000-1fd00-0bp0-3rd1-programmable-logic-controller","title":"Siemens 3RD1000-1FD00-0BP0 3RD1 Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 3RD1000-1FD00-0BP0 is a programmable logic controller from the SENTRON\/SIRIUS 3RD1 series. SIMATIC ET 200SP e-Starter fan unit with 2 fans. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FD00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP on the front according to IEC 60529\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.028 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch protection on the front according to IEC 60529\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efinger-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esnap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.028 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RD1000-1FD00-0BP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RD1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620074352923,"sku":"3RD1000-1FD00-0BP0","price":138.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rd1000-1fd00-0bp0.webp?v=1784379802"},{"product_id":"siemens-3rd1000-1fs00-0bp0-3rd1-programmable-logic-controller","title":"Siemens 3RD1000-1FS00-0BP0 3RD1 Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 3RD1000-1FS00-0BP0 is a programmable logic controller from the SENTRON\/SIRIUS 3RD1 series. SIMATIC ET 200SP e-Starter fan unit with 1 fan. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1FS00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP on the front according to IEC 60529\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.023 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch protection on the front according to IEC 60529\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efinger-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esnap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.023 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RD1000-1FS00-0BP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RD1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620074582299,"sku":"3RD1000-1FS00-0BP0","price":79.96,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rd1000-1fs00-0bp0.webp?v=1784379811"},{"product_id":"siemens-3rd1000-1mb00-0bp0-3rd1-programmable-logic-controller","title":"Siemens 3RD1000-1MB00-0BP0 3RD1 Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 3RD1000-1MB00-0BP0 is a programmable logic controller from the SENTRON\/SIRIUS 3RD1 series. SIMATIC ET 200SP e-Starter basic 4DI (LC) submodule. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1000-1MB00-0BP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RD1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp-up (soft starting)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoft stopping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoft Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO) via F-DI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Torque Off (STO) via PROFIsafe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCreep speed in both directions of rotation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump stop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\/max pointer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrace function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary state detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching of capacitive loads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmart Start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReversing brakes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection of direction of rotation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.043 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RD1000-1MB00-0BP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RD1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620074713371,"sku":"3RD1000-1MB00-0BP0","price":138.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rd1000-1mb00-0bp0.webp?v=1784379818"},{"product_id":"siemens-6gk1210-0sa01-6gk1-programmable-logic-controller","title":"Siemens 6GK1210-0SA01 6GK1 Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 6GK1210-0SA01 is a programmable logic controller from the SENTRON\/SIRIUS 6GK1 series. SIMATIC NET, Repeater for AS-Interface for cable extension in K45 enclosure. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1210-0SA01\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS-Interface Repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eno slave integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the AS-Interface connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect connection to AS-i ribbon cable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature during operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.122 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 6GK1210-0SA01 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 6GK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620075434267,"sku":"6GK1210-0SA01","price":424.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1210-0sa01.webp?v=1784379828"},{"product_id":"siemens-6es7400-0hr01-4ab0-s7-400h-412-5h-bundle-ac","title":"Siemens 6ES7400-0HR01-4AB0 SIMATIC S7-400H CPU 412-5H System Bundle AC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR01-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 412-5H controllers. It ships with one UR2-H rack, 2x PS407 UC120\/230V, 10 A, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR01-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792681\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 412-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS407 UC120\/230V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits at the entry point of the S7-400H CPU line offered here; step up to the equivalent bundle with a higher-numbered CPU when the application needs more program memory or scan-time headroom than the 412-5H provides. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS407 supplies run on 120\/230 V AC, so this variant suits sites with AC distribution; the DC-supply version of the same CPU bundle covers 24\/48\/60 V DC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960577581339,"sku":"6ES7400-0HR01-4AB0","price":15340.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr01-4ab0-s7-400h-412-5h-bundle-ac.png?v=1789781924"},{"product_id":"siemens-6es7400-0hr02-4ab0-s7-400h-414-5h-bundle-ac","title":"Siemens 6ES7400-0HR02-4AB0 SIMATIC S7-400H CPU 414-5H System Bundle AC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR02-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 414-5H controllers. It ships with one UR2-H rack, 2x PS407 UC120\/230V, 10 A, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR02-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 414-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS407 UC120\/230V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits between the smaller and larger CPU bundles in the S7-400H line; drop to the lower-numbered CPU bundle if the application is lighter, or step up to a higher-numbered one if scan-time or memory headroom is tight. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS407 supplies run on 120\/230 V AC, so this variant suits sites with AC distribution; the DC-supply version of the same CPU bundle covers 24\/48\/60 V DC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960577777947,"sku":"6ES7400-0HR02-4AB0","price":25766.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr02-4ab0-s7-400h-414-5h-bundle-ac.png?v=1789781931"},{"product_id":"siemens-6es7400-0hr03-4ab0-s7-400h-416-5h-bundle-ac","title":"Siemens 6ES7400-0HR03-4AB0 SIMATIC S7-400H CPU 416-5H System Bundle AC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR03-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 416-5H controllers. It ships with one UR2-H rack, 2x PS407 UC120\/230V, 10 A, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR03-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 416-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS407 UC120\/230V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits between the smaller and larger CPU bundles in the S7-400H line; drop to the lower-numbered CPU bundle if the application is lighter, or step up to the largest CPU bundle in the line if headroom is tight. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS407 supplies run on 120\/230 V AC, so this variant suits sites with AC distribution; the DC-supply version of the same CPU bundle covers 24\/48\/60 V DC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960577974555,"sku":"6ES7400-0HR03-4AB0","price":36672.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr03-4ab0-s7-400h-416-5h-bundle-ac.png?v=1789781938"},{"product_id":"siemens-6es7400-0hr04-4ab0-s7-400h-417-5h-bundle-ac","title":"Siemens 6ES7400-0HR04-4AB0 SIMATIC S7-400H CPU 417-5H System Bundle AC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR04-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 417-5H controllers. It ships with one UR2-H rack, 2x PS407 UC120\/230V, 10 A, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR04-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 417-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS407 UC120\/230V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle carries the largest CPU offered in this S7-400H bundle line; choose it when the application already saturates the memory or scan-time budget of the lower-numbered CPU bundles. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS407 supplies run on 120\/230 V AC, so this variant suits sites with AC distribution; the DC-supply version of the same CPU bundle covers 24\/48\/60 V DC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960578203931,"sku":"6ES7400-0HR04-4AB0","price":46269.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr04-4ab0-s7-400h-417-5h-bundle-ac.png?v=1789781944"},{"product_id":"siemens-6es7400-0hr51-4ab0-s7-400h-412-5h-bundle-dc","title":"Siemens 6ES7400-0HR51-4AB0 SIMATIC S7-400H CPU 412-5H System Bundle DC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR51-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 412-5H controllers. It ships with one UR2-H rack, 2x PS 405 10A, 24\/48\/60 V DC, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR51-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 412-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS 405 10A, 24\/48\/60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits at the entry point of the S7-400H CPU line offered here; step up to the equivalent bundle with a higher-numbered CPU when the application needs more program memory or scan-time headroom than the 412-5H provides. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS 405 supplies run on 24\/48\/60 V DC, so this variant suits sites with DC distribution already in place; the AC-supply version of the same CPU bundle covers 120\/230 V AC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960578400539,"sku":"6ES7400-0HR51-4AB0","price":15374.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr51-4ab0-s7-400h-412-5h-bundle-dc.png?v=1789781951"},{"product_id":"siemens-6es7400-0hr52-4ab0-s7-400h-414-5h-bundle-dc","title":"Siemens 6ES7400-0HR52-4AB0 SIMATIC S7-400H CPU 414-5H System Bundle DC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR52-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 414-5H controllers. It ships with one UR2-H rack, 2x PS 405 10A, 24\/48\/60 V DC, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR52-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 414-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS 405 10A, 24\/48\/60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits between the smaller and larger CPU bundles in the S7-400H line; drop to the lower-numbered CPU bundle if the application is lighter, or step up to a higher-numbered one if scan-time or memory headroom is tight. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS 405 supplies run on 24\/48\/60 V DC, so this variant suits sites with DC distribution already in place; the AC-supply version of the same CPU bundle covers 120\/230 V AC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960578597147,"sku":"6ES7400-0HR52-4AB0","price":26333.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr52-4ab0-s7-400h-414-5h-bundle-dc.png?v=1789781957"},{"product_id":"siemens-6es7400-0hr53-4ab0-s7-400h-416-5h-bundle-dc","title":"Siemens 6ES7400-0HR53-4AB0 SIMATIC S7-400H CPU 416-5H System Bundle DC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR53-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 416-5H controllers. It ships with one UR2-H rack, 2x PS 405 10A, 24\/48\/60 V DC, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR53-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792742\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 416-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS 405 10A, 24\/48\/60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle sits between the smaller and larger CPU bundles in the S7-400H line; drop to the lower-numbered CPU bundle if the application is lighter, or step up to the largest CPU bundle in the line if headroom is tight. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS 405 supplies run on 24\/48\/60 V DC, so this variant suits sites with DC distribution already in place; the AC-supply version of the same CPU bundle covers 120\/230 V AC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960578957595,"sku":"6ES7400-0HR53-4AB0","price":36759.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr53-4ab0-s7-400h-416-5h-bundle-dc.png?v=1789781963"},{"product_id":"siemens-6es7400-0hr54-4ab0-s7-400h-417-5h-bundle-dc","title":"Siemens 6ES7400-0HR54-4AB0 SIMATIC S7-400H CPU 417-5H System Bundle DC UR2-H Redundant PLC","description":"\u003cp\u003eThe Siemens 6ES7400-0HR54-4AB0 is a SIMATIC S7-400H redundant system bundle built around two CPU 417-5H controllers. It ships with one UR2-H rack, 2x PS 405 10A, 24\/48\/60 V DC, four synchronization modules for cable runs up to 10 m, and two 1 m sync cables; the memory cards and backup batteries needed to complete the H-system pair are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7400-0HR54-4AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948792759\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eSystem bundle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Rack\u003c\/td\u003e\n\u003ctd\u003e1x UR2-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded CPU\u003c\/td\u003e\n\u003ctd\u003e2x CPU 417-5H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Power Supply\u003c\/td\u003e\n\u003ctd\u003e2x PS 405 10A, 24\/48\/60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Modules\u003c\/td\u003e\n\u003ctd\u003e4x, cable run up to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Synchronization Cables\u003c\/td\u003e\n\u003ctd\u003e2x, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003eNot included - 2x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eNot included - 4x required, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis bundle carries the largest CPU offered in this S7-400H bundle line; choose it when the application already saturates the memory or scan-time budget of the lower-numbered CPU bundles. All four synchronization modules needed to link the redundant CPU pair ship in the box, so no separate sync hardware has to be sourced when building the H-system. The included PS 405 supplies run on 24\/48\/60 V DC, so this variant suits sites with DC distribution already in place; the AC-supply version of the same CPU bundle covers 120\/230 V AC installations instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960579154203,"sku":"6ES7400-0HR54-4AB0","price":46392.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7400-0hr54-4ab0-s7-400h-417-5h-bundle-dc.png?v=1789781970"},{"product_id":"siemens-6es7412-1xj07-0ab0-cpu-412-1","title":"Siemens 6ES7412-1XJ07-0AB0 SIMATIC S7-400 CPU 412-1 512KB MPI\/DP Programmable Logic Controller","description":"\u003cp\u003eThe Siemens CPU 412-1 (6ES7412-1XJ07-0AB0) is a SIMATIC S7-400 central processing unit with 512 KB of work memory, split 256 KB for program and 256 KB for data, and a single combined MPI\/DP interface running at up to 12 Mbit\/s. It takes one rack slot and runs bit and word instructions in 31.25 ns typical, making it a baseline choice for single-interface S7-400 stations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7412-1XJ07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 412-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPI\/DP, 12 Mbit\/s, isochronous mode for PROFIBUS only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.4 or higher with HSP 261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 kbyte (256 kbyte program, 256 kbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (FLASH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (RAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 850 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 A typ., 0.8 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, floating point, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 inputs, 32768 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 inputs, 2048 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulticomputing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 CPUs with UR1 or UR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware real-time clock, retentive, 1 ms resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eA single MPI\/DP interface means one PROFIBUS DP network or MPI programming connection at a time, which fits stations where the CPU only needs to talk to a programming device and one field network. The 512 KB work memory and 3000-DB limit suit small to mid-size logic; projects with more data blocks, a second dedicated PROFIBUS interface, or higher I\/O counts should move up within the S7-400 CPU line rather than push this unit past its 21-expansion-unit and 47-OP connection limits.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960583741723,"sku":"6ES7412-1XJ07-0AB0","price":1934.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7412-1xj07-0ab0-cpu-412-1.png?v=1789782059"},{"product_id":"siemens-6es7412-2ek07-0ab0-cpu-412-2-pn","title":"Siemens 6ES7412-2EK07-0AB0 SIMATIC S7-400 CPU 412-2 PN 1MB MPI\/DP PROFINET Programmable Logic Controller","description":"\u003cp\u003eThe Siemens 6ES7412-2EK07-0AB0 is a SIMATIC S7-400 CPU 412-2 PN central processing unit with 1 MB of work memory split 512 KB program \/ 512 KB data, and two interfaces: a 12 Mbit\/s MPI\/DP port and an Ethernet\/PROFINET port. It supports up to 21 expansion units and multicomputing with up to 4 CPUs in one UR1 or UR2 rack.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7412-2EK07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 412-2 PN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, program\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB (Memory Card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery-backed, all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU processing time, bit \/ word, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.25 ns \/ 31.25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB \/ FB \/ FC, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 \/ 1500 \/ 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O address area, inputs \/ outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 KB \/ 4 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels, inputs \/ outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 \/ 32768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels, inputs \/ outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 \/ 2048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulticomputing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, up to 4 CPUs (UR1\/UR2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IO Controllers, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of PROFIBUS\/PROFINET CPs, recommended\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.977 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe -2 PN designation adds an integrated Ethernet\/PROFINET port alongside the MPI\/DP interface, so PROFINET IO devices connect directly to the CPU without a separate CP 443-1 module — choose this over a DP-only 412 CPU when the plant network is PROFINET-based. Multicomputing support for up to 4 CPUs in one UR1\/UR2 rack lets a program split across CPUs when a single 1 MB work memory (512 KB program \/ 512 KB data) is not enough for the application; for programs that fit in one CPU, the simpler single-CPU rack layout is sufficient.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to S7-400 rack-based process and machine control retrofits that need PROFINET IO connectivity without re-architecting an existing MPI\/DP installation, and to multicomputing configurations that distribute a large control program across several CPUs sharing one backplane.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584102171,"sku":"6ES7412-2EK07-0AB0","price":4347.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7412-2ek07-0ab0-cpu-412-2-pn-plc.png?v=1789680597"},{"product_id":"siemens-6es7412-2xk07-0ab0-cpu-412-2","title":"Siemens 6ES7412-2XK07-0AB0 SIMATIC S7-400 CPU 412-2 1MB MPI\/DP PROFIBUS DP PLC","description":"\u003cp\u003eThe Siemens CPU 412-2 (6ES7412-2XK07-0AB0) is a SIMATIC S7-400 central processing unit with 1 MB of work memory, split 512 KB for program and 512 KB for data, plus two integrated interfaces: a combined MPI\/DP port and a dedicated PROFIBUS DP port, each running at up to 12 Mbit\/s. It takes one rack slot and runs bit and word instructions in 31.25 ns typical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7412-2XK07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 412-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st MPI\/DP, 2nd PROFIBUS DP, both 12 Mbit\/s, isochronous mode for PROFIBUS only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.4 or higher with HSP 261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mbyte (512 kbyte program, 512 kbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (FLASH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (RAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 850 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 A typ., 1.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, floating point, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 inputs, 32768 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 inputs, 2048 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulticomputing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 CPUs with UR1 or UR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware real-time clock, retentive, 1 ms resolution, synchronizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe second, dedicated PROFIBUS DP interface is the practical difference from the single-interface variant: it lets the CPU run a field network on port two while keeping MPI free for programming and HMI traffic on port one, so both connections are live at the same time instead of shared over one port. Doubled work memory, 1 MB against 512 KB, and a 6000-entry DB range instead of 3000 give more headroom for larger programs. Backplane current draw rises only slightly, 0.9 A typical versus 0.7 A, so the extra interface does not demand a bigger power supply in most single-rack layouts.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584298779,"sku":"6ES7412-2XK07-0AB0","price":3758.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7412-2xk07-0ab0-cpu-412-2.png?v=1789782065"},{"product_id":"siemens-6es7412-5hk06-0ab0-cpu-412-5h","title":"Siemens 6ES7412-5HK06-0AB0 SIMATIC S7-400H CPU 412-5H PN\/DP 1MB Fault-Tolerant Controller","description":"\u003cp\u003eThe Siemens CPU 412-5H PN\/DP (6ES7412-5HK06-0AB0) is a fault-tolerant central processing unit for SIMATIC S7-400H and S7-400F\/FH systems, with 1 MB of work memory split 512 KB program and 512 KB data. Five interfaces cover MPI\/DP, a dedicated DP port, PROFINET, and two synchronization module ports for redundant CPU pairing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7412-5HK06-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 412-5H PN\/DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x MPI\/DP, 1x DP, 1x PN, 2 for synchronization modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.5 SP2 with HF1 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mbyte (512 kbyte program, 512 kbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 1000 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 A typ., 1.9 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65536 inputs, 65536 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 inputs, 4096 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IO controllers, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVia MPI, DP, AS and Ethernet NTP (as client), 10 ms max. deviation via NTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe two synchronization-module ports are what set this CPU apart from the standard 412 line: they pair a redundant CPU for S7-400H fault-tolerant operation, or run fail-safe F-blocks on S7-400F\/FH systems. The integrated PROFINET IO controller adds Ethernet-based I\/O alongside the MPI\/DP and DP ports, so this variant fits process or safety-relevant plants where a single CPU failure cannot stop the line, rather than the simpler single-CPU 412-1 or 412-2 used in non-redundant stations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584397083,"sku":"6ES7412-5HK06-0AB0","price":4859.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7412-5hk06-0ab0-cpu-412-5h.png?v=1789782071"},{"product_id":"siemens-6es7414-2xl07-0ab0-cpu-414-2","title":"Siemens 6ES7414-2XL07-0AB0 SIMATIC S7-400 CPU 414-2 2MB MPI\/DP PROFIBUS DP PLC","description":"\u003cp\u003eThe Siemens CPU 414-2 (6ES7414-2XL07-0AB0) is a SIMATIC S7-400 central processing unit with 2 MB of work memory, split 1 MB for program and 1 MB for data, plus two integrated interfaces: a combined MPI\/DP port and a dedicated PROFIBUS DP port. Bit and word instructions run in 18.75 ns typical, faster than the 412 line, for programs with larger logic and data footprints.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7414-2XL07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 414-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st MPI\/DP, 2nd PROFIBUS DP, both 12 Mbit\/s, isochronous mode for PROFIBUS only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.4 or higher with HSP 261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Mbyte (1 Mbyte program, 1 Mbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (FLASH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (RAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 850 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 A typ., 1.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, floating point, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65536 inputs, 65536 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 inputs, 4096 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulticomputing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 CPUs with UR1 or UR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware real-time clock, retentive, 1 ms resolution, synchronizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eDoubled work memory versus the 412-2, 2 MB against 1 MB, and an instruction time nearly 40 percent faster, 18.75 ns instead of 31.25 ns, make this CPU the choice once program size or scan-time budget outgrows the 412 line while keeping the same MPI\/DP plus PROFIBUS DP interface pair. The DB range already reaches 6000 blocks, so projects staying below that count gain little from moving further up the family; those with heavier PROFINET or multi-interface requirements need a PN\/DP-equipped CPU instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584495387,"sku":"6ES7414-2XL07-0AB0","price":5196.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7414-2xl07-0ab0-cpu-414-2.png?v=1789782077"},{"product_id":"siemens-6es7414-3em07-0ab0-cpu-414-3-pndp","title":"Siemens 6ES7414-3EM07-0AB0 SIMATIC S7-400 CPU 414-3 PN\/DP 4MB 3 Interfaces PLC","description":"\u003cp\u003eThe Siemens CPU 414-3 PN\/DP (6ES7414-3EM07-0AB0) is a SIMATIC S7-400 central processing unit with 4 MB of work memory, split 2 MB program and 2 MB data, and three interfaces: MPI\/DP on X1, integrated Ethernet\/PROFINET on X5, and a plug-in IF 964-DP port. It runs bit and word instructions in 18.75 ns typical and takes two rack slots.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7414-3EM07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 414-3 PN\/DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX1 MPI\/DP 12 Mbit\/s, X5 Ethernet\/PROFINET, IF1 plug-in IF 964-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.5 or higher with HSP 262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mbyte (2 Mbyte program, 2 Mbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (FLASH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (RAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 850 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 A typ., 1.6 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65536 inputs, 65536 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 inputs, 4096 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, plus 1 via IF 964-DP interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IO controllers, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware real-time clock, retentive, 1 ms resolution, synchronizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe integrated PROFINET interface on X5 plus an IF 964-DP plug-in slot give this CPU three live networks at once, MPI\/DP, PROFINET IO, and a second PROFIBUS DP master, where the 414-2 offers only MPI\/DP and one PROFIBUS DP port. That third interface is the reason to pick this variant over the 414-2: stations mixing PROFINET IO devices with an existing PROFIBUS DP segment can run both without a separate communication processor. The extra slot requirement and 6.5 W power loss reflect the added PROFINET hardware on board.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584659227,"sku":"6ES7414-3EM07-0AB0","price":9167.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7414-3em07-0ab0-cpu-414-3-pndp.png?v=1789782083"},{"product_id":"siemens-6es7414-3fm07-0ab0-cpu-414f-3-pndp","title":"Siemens 6ES7414-3FM07-0AB0 SIMATIC S7-400 CPU 414F-3 PN\/DP 4MB Fail-Safe PLC","description":"\u003cp\u003eFail-safe function blocks distinguish the Siemens CPU 414F-3 PN\/DP (6ES7414-3FM07-0AB0) from the standard 414-3: it is a SIMATIC S7-400 CPU built for safety-related SIMATIC S7-400F\/FH programs, with 4 MB of work memory (2 MB program, 2 MB data) across three interfaces, MPI\/DP on X1, Ethernet\/PROFINET on X5, and a plug-in IF 964-DP port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7414-3FM07-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU 414F-3 PN\/DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX1 MPI\/DP 12 Mbit\/s, X5 Ethernet\/PROFINET, IF1 plug-in IF 964-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 V5.5 or higher with HSP 262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork memory, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mbyte (2 Mbyte program, 2 Mbyte data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable FEPROM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (FLASH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad memory, expandable RAM, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Mbyte via Memory Card (RAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePresent, backs up all data; typ. 180 uA, max. 850 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current, backplane bus 5 V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 A typ., 1.6 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing time, bit\/word operations, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDB, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000, numbered 1 to 16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFB \/ FC, number max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 each, numbered 0 to 7999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of startup OBs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, OB 100 and OB 102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65536 inputs, 65536 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 inputs, 4096 outputs, all central\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of DP masters, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, plus 1 via IF 964-DP interface module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IO controllers, integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of expansion units, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable OPs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the F-3 over the standard 414-3 when the program includes safety functions written with F-blocks for an S7-400F or S7-400FH station; the underlying hardware, memory, and three-interface layout are otherwise identical. Only the startup-OB count differs in the verified data, two on this CPU against three on the non-safety 414-3, reflecting the more constrained startup sequence a safety-rated CPU runs. Where no F-blocks are needed, the standard 414-3 PN\/DP is the simpler and functionally equivalent pick.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960584724763,"sku":"6ES7414-3FM07-0AB0","price":9658.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7414-3fm07-0ab0-cpu-414f-3-pndp.png?v=1789782089"}],"url":"https:\/\/stoklink.com\/collections\/plc-cpu.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}