{"title":"Communication \u0026 Fieldbus Modules","description":"\u003cp\u003ePLC communication and fieldbus modules from Siemens, Schneider Electric and ABB. The range has over 100 products: SIMATIC NET communication processors, PROFIBUS and PROFINET modules, gateways, Modicon X80 serial modules and ANYBUS interfaces. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSIMATIC NET CP modules, such as CP 343-1, CP 443-1 and CP 5612 PCI cards.\u003c\/li\u003e\n\u003cli\u003ePROFIBUS and PROFINET modules, including the PN\/CAN LINK gateway.\u003c\/li\u003e\n\u003cli\u003eModicon X80 serial link modules with RS232 and RS485 ports.\u003c\/li\u003e\n\u003cli\u003eBus couplers and panel servers from the Schneider Electric TeSys Island and EcoStruxure range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProtocol: PROFINET, PROFIBUS, EtherNet\/IP, Modbus or CANopen must match both ends of the link.\u003c\/li\u003e\n\u003cli\u003eController compatibility: communication processors are tied to a CPU family and rack.\u003c\/li\u003e\n\u003cli\u003ePhysical interface: RJ45, M12, D-sub or RS485, and port count.\u003c\/li\u003e\n\u003cli\u003eSpeed: Fast Ethernet or Gigabit for large data volumes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eDoes a CP 343-1 work in an S7-1500 rack?\u003c\/h3\u003e\n\u003cp\u003eNo. CP 343-1 belongs to the S7-300 family. S7-1500 uses its own communication modules, so select by CPU family.\u003c\/p\u003e\n\u003ch3\u003eWhat is a PN\/CAN LINK used for?\u003c\/h3\u003e\n\u003cp\u003eIt connects a PROFINET network to a CANopen network and passes data between the two.\u003c\/p\u003e\n\u003ch3\u003eDo you export communication modules?\u003c\/h3\u003e\n\u003cp\u003eStoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"abb-1sfa899300r1006-ab-ethernet-ip-2-fieldbus-module","title":"ABB 1SFA899300R1006 AB-ETHERNET-IP-2 ANYBUS EtherNet\/IP Fieldbus Communication Module 50x22x52mm","description":"\u003cp\u003eThe ABB AB-ETHERNET-IP-2 (SKU: 1SFA899300R1006) is an ANYBUS series EtherNet\/IP fieldbus communication module designed for decentralised peripheral communication in industrial automation systems. This compact module measures 50 x 22 x 52 mm and weighs just 0.03 kg, making it ideal for space-constrained control panel installations requiring reliable network connectivity and seamless integration with EtherNet\/IP-based control architectures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-ETHERNET-IP-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFieldbus, decentr. periphery-communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 22 x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances directive, ensuring the module is free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant following the July 22, 2019 amendment, confirming restricted substance compliance across the product lifecycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive, supporting responsible end-of-life disposal and recycling obligations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDecentralised I\/O communication in industrial automation control panels\u003c\/li\u003e\n\u003cli\u003eEtherNet\/IP network integration for ABB ANYBUS-compatible devices\u003c\/li\u003e\n\u003cli\u003eFactory automation systems requiring fieldbus connectivity\u003c\/li\u003e\n\u003cli\u003eMachine control architectures using distributed peripheral communication\u003c\/li\u003e\n\u003cli\u003ePLC and HMI network expansion via EtherNet\/IP protocol\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229347615003,"sku":"1SFA899300R1006","price":381.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1006-ab-ethernet-ip-2-communication-module-50x22x52mm_f55d0219-3e36-4cf1-aa42-7f2c8b67c3dd.webp?v=1777160209"},{"product_id":"abb-1sfa899300r1002-ab-devicenet-1-fieldbus-module","title":"ABB 1SFA899300R1002 AB-DEVICENET-1 ANYBUS Series DeviceNet Fieldbus Communication Module","description":"\u003cp\u003eThe ABB AB-DEVICENET-1 (SKU: 1SFA899300R1002) is an ANYBUS Series DeviceNet fieldbus communication module designed for decentralised peripheral communication in industrial automation systems. Enabling seamless integration of ABB devices onto DeviceNet networks, the AB-DEVICENET-1 delivers reliable fieldbus connectivity in a compact 50 × 61.7 × 22.25 mm form factor weighing just 31 g, making it ideal for space-constrained control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-DEVICENET-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFieldbus Decentralised Periphery Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 × 61.7 × 22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.031 kg (31 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Compliant with the European RoHS Directive restricting hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the updated RoHS substance restrictions introduced by EU Directive 2015\/863\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered and compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDeviceNet fieldbus network integration for ABB drives and soft starters\u003c\/li\u003e\n\u003cli\u003eDecentralised I\/O and peripheral communication in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eControl panel installations requiring compact fieldbus adapter modules\u003c\/li\u003e\n\u003cli\u003eFactory automation and process control environments using DeviceNet infrastructure\u003c\/li\u003e\n\u003cli\u003ePLC and DCS integration via DeviceNet protocol in manufacturing plants\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229347713307,"sku":"1SFA899300R1002","price":273.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1002-ab-devicenet-1-fieldbus-communication-module_a24a2ef6-f6b2-491a-a926-66c3617e7e00.webp?v=1777160199"},{"product_id":"abb-1sfa899300r1001-ab-profibus-1-fieldbus-communication-module","title":"ABB 1SFA899300R1001 AB-PROFIBUS-1 ANYBUS PROFIBUS Communication Module Fieldbus Decentralized Periphery","description":"\u003cp\u003eThe ABB AB-PROFIBUS-1 (SKU: 1SFA899300R1001) is a PROFIBUS fieldbus communication module from the ANYBUS series, designed to enable decentralized periphery communication in industrial automation and control panel applications. Engineered for seamless integration into distributed I\/O architectures, this compact module measures 50 × 56.6 × 22.25 mm and weighs only 0.029 kg, making it an ideal solution for space-constrained control cabinet installations.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-PROFIBUS-1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFieldbus Decentralized Periphery Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.029 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances Directive, ensuring the module is free from restricted hazardous materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) for chemical substance safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Fully compliant with the European RoHS Directive on the restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the 2015\/863\/EU amendment updating the list of restricted substances under RoHS 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePROFIBUS DP network integration in decentralized I\/O systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation and PLC-based control architectures\u003c\/li\u003e\n  \u003cli\u003eControl panel and cabinet communication infrastructure\u003c\/li\u003e\n  \u003cli\u003eMotor control centers requiring fieldbus connectivity\u003c\/li\u003e\n  \u003cli\u003eManufacturing and process automation environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229348008219,"sku":"1SFA899300R1001","price":273.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1001-ab-profibus-1-fieldbus-decentralized-periphery_b03545df-50df-49c2-a8fa-cd839123f766.webp?v=1777160194"},{"product_id":"abb-1sfa899300r1003-ab-modbus-rtu-1-communication-module","title":"ABB 1SFA899300R1003 AB-MODBUS-RTU-1 ANYBUS Modbus RTU Communication Module Fieldbus Decentralized Periphery","description":"\u003cp\u003eThe ABB AB-MODBUS-RTU-1 (SKU: 1SFA899300R1003) is a Modbus RTU fieldbus communication module from the ABB ANYBUS series, designed for decentralized periphery integration in industrial automation and control systems. Enabling seamless serial Modbus RTU connectivity, this compact module measures just 50 × 56.5 × 22.25 mm and weighs only 0.028 kg, making it ideal for space-constrained control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-MODBUS-RTU-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFieldbus \/ Decentralized Periphery Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.028 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) for safe chemical substances in products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Meets the European Union RoHS recast directive requirements for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the EU amendment extending RoHS substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for proper end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDecentralized field device communication via Modbus RTU serial protocol\u003c\/li\u003e\n\u003cli\u003eIntegration of ABB ANYBUS-compatible devices into industrial automation networks\u003c\/li\u003e\n\u003cli\u003eControl panel and switchgear automation in manufacturing and process industries\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control systems requiring fieldbus connectivity\u003c\/li\u003e\n\u003cli\u003eMachine control systems leveraging Modbus RTU for sensor and actuator communication\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229348237595,"sku":"1SFA899300R1003","price":273.71,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1003-ab-modbus-rtu-1-fieldbus-decentralized-periphery_c3cb215d-688c-470a-a00d-3828ef20a16d.webp?v=1777160204"},{"product_id":"abb-1sfa899300r1008-ab-modbus-tcp-2-communication-module","title":"ABB 1SFA899300R1008 AB-MODBUS-TCP-2 ANYBUS Modbus TCP Communication Module","description":"\u003cp\u003eThe ABB \u003cstrong\u003eAB-MODBUS-TCP-2\u003c\/strong\u003e (SKU: 1SFA899300R1008) is an ANYBUS series Modbus TCP communication module designed for seamless integration of ABB devices into industrial Ethernet-based automation networks. Compact and lightweight at just 27 g with dimensions of 50 × 54.81 × 22.25 mm, this module enables reliable Modbus TCP\/IP connectivity in control panel and automation system applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-MODBUS-TCP-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.027 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the module is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), confirming safe chemical substance management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life recycling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntegrating ABB soft starters, motor controllers, and drives into Modbus TCP\/IP industrial Ethernet networks\u003c\/li\u003e\n\u003cli\u003eControl panel automation and SCADA system connectivity\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation requiring standardised fieldbus communication\u003c\/li\u003e\n\u003cli\u003eBuilding automation and factory automation infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229348565275,"sku":"1SFA899300R1008","price":368.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1008-ab-modbus-tcp-2-fieldbus-communication-module_149a31de-f0a6-4954-862c-8a7470bf299a.webp?v=1777160213"},{"product_id":"abb-1sfa899300r1010-ab-profinet-io-2-communication-module","title":"ABB 1SFA899300R1010 AB-PROFINET-IO-2 ANYBUS PROFINET IO Fieldbus Decentralised Periphery Communication Module","description":"\u003cp\u003eThe ABB AB-PROFINET-IO-2 (SKU: 1SFA899300R1010) is an ANYBUS series fieldbus communication module designed for decentralised periphery integration via the PROFINET IO protocol. This compact module enables seamless connectivity between ABB automation devices and PROFINET IO networks, making it an essential component for modern industrial automation and control panel architectures. Weighing just 0.028 kg with a footprint of 50 × 55.1 × 22.25 mm, the AB-PROFINET-IO-2 fits easily into space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-PROFINET-IO-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFieldbus \/ Decentralised Periphery Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 × 55.1 × 22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.028 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Meets the European Union RoHS recast directive for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the 2015\/863\/EU amendment extending substance restrictions under RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntegration of ABB soft starters, motor controllers, and drives into PROFINET IO networks\u003c\/li\u003e\n\u003cli\u003eDecentralised I\/O periphery communication in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eFactory automation and process control architectures requiring PROFINET connectivity\u003c\/li\u003e\n\u003cli\u003eControl panel builds where fieldbus communication modules are required for distributed intelligence\u003c\/li\u003e\n\u003cli\u003eMachine builders and OEMs standardising on PROFINET IO for fieldbus infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229348696347,"sku":"1SFA899300R1010","price":552.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1010-ab-profinet-io-2-periphery-communication-module_b6e10d87-5b51-48b7-81f2-fa68995fd1e7.webp?v=1777160217"},{"product_id":"schneider-electric-tprbceip-tesys-island-bus-coupler","title":"Schneider Electric TPRBCEIP TeSys Island TPRBC 24V DC EtherNet\/IP Bus Coupler PLC Communication Module","description":"\u003cp\u003eThe Schneider Electric TPRBCEIP is a TeSys island bus coupler (device short name TPRBC) supplied at 24 V DC, 3 A maximum, providing two EtherNet\/IP or Modbus TCP fieldbus ports plus a service port for the automation controller connection. It manages the complete TeSys island configuration of up to 20 modules from the leftmost DIN-rail position.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPRBCEIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys island\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPRBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication port protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x RJ45 fieldbus (EtherNet\/IP \/ Modbus TCP), 1x RJ45 service port, 1x micro SD card port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP adapter, Modbus TCP server, DHCP client, BOOTP client, SNMP client, SNTP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated supply voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4...28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAchilles certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\/vertical, 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10...60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 50 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.204 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eAchilles level 2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003eUL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs the leftmost module in a TeSys island configuration, the TPRBCEIP is the single point of connection between the automation controller and up to 20 downstream starter and I\/O modules over EtherNet\/IP or Modbus TCP. Its 3 A \/ 24 V DC supply powers the entire island through one connection point rather than powering each module individually. The embedded web server and micro SD card port support diagnostics and configuration backup without a separate engineering tool session. Choose this EtherNet\/IP-and-Modbus TCP variant when the automation controller runs one of those protocols; a Profinet IO version of this bus coupler covers Profinet-based architectures instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230468182299,"sku":"TPRBCEIP","price":245.32,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tprbceip-tesys-island-bus-coupler.jpg?v=1790287418"},{"product_id":"schneider-electric-tprbcpfn-tesys-island-bus-coupler","title":"Schneider Electric TPRBCPFN TeSys Island TPRBC 24V DC Profinet IO Bus Coupler PLC Communication Module","description":"\u003cp\u003eThe Schneider Electric TPRBCPFN is a TeSys island bus coupler (device short name TPRBC) supplied at 24 V DC, 3 A maximum, providing two Profinet IO fieldbus ports plus a service port for the automation controller connection. It manages the complete TeSys island configuration of up to 20 modules from the leftmost DIN-rail position.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPRBCPFN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys island\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPRBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication port protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProfinet IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x RJ45 fieldbus (Profinet IO), 1x RJ45 service port, 1x micro SD card port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformance class A (CC-A), Net load class 1, DHCP client, SNTP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated supply voltage (Us)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4...28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAchilles certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\/vertical, 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10...60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 50 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.204 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eAchilles level 2\u003c\/li\u003e\n\u003cli\u003ePNO\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003eUL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61010-2-201\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs the leftmost module in a TeSys island configuration, the TPRBCPFN is the single point of connection between the automation controller and up to 20 downstream starter and I\/O modules over Profinet IO, at Conformance Class A. Its 3 A \/ 24 V DC supply powers the entire island through one connection point rather than powering each module individually. The embedded web server and micro SD card port support diagnostics and configuration backup without a separate engineering tool session. Choose this Profinet IO variant for Siemens-style Profinet architectures; an EtherNet\/IP and Modbus TCP version of this bus coupler covers those protocols instead.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230468247835,"sku":"TPRBCPFN","price":245.32,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tprbcpfn-tesys-island-bus-coupler.jpg?v=1790287428"},{"product_id":"schneider-electric-bmxeia0100-x80-as-i-master-module","title":"Schneider Electric BMXEIA0100 Modicon X80 AS-Interface Master Communication Module","description":"\u003cp\u003eThe Schneider Electric BMXEIA0100 is a Modicon X80 AS-Interface (AS-i) master module supporting up to 62 discrete I\/O devices or 31 analog I\/O devices on a single AS-i network. It draws 160 mA at 3.3 V DC, connects via a 3-pin SUB-D male connector, and carries an IP20 enclosure rating with Class I Division 2 hazardous-location approval.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eBMXEIA0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3595864038032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMaster module (AS-Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i Master Profile\u003c\/td\u003e\n\u003ctd\u003eM4 master profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i Slave Profiles Supported\u003c\/td\u003e\n\u003ctd\u003eS7.3, S7.A.7, S7.A.A, S7.A.8, S7.A.9, S6.0.X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing\u003c\/td\u003e\n\u003ctd\u003eStandard and extended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle Time\u003c\/td\u003e\n\u003ctd\u003e5 ms (31 devices) \/ 10 ms (62 devices)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer Devices (standard)\u003c\/td\u003e\n\u003ctd\u003e124 discrete I\/O, 124 analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer Devices (extended)\u003c\/td\u003e\n\u003ctd\u003e496 discrete I\/O, 124 analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e1 male SUB-D connector, 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance\u003c\/td\u003e\n\u003ctd\u003e100 m (200 m line extension; 300 m with 2 repeaters; 500 m with 2 repeaters, master at center)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Characteristic\u003c\/td\u003e\n\u003ctd\u003eHazardous location, Class I Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eMerchant Navy\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eIECEx Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2\u003c\/li\u003e\n\u003cli\u003eIEC 61010-2-201\u003c\/li\u003e\n\u003cli\u003eUL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eIEC 61000-6-5\u003c\/li\u003e\n\u003cli\u003eIEC 61850-3\u003c\/li\u003e\n\u003cli\u003eIEC 60079-0\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BMXEIA0100's standard addressing mode covers 124 AS-i server devices (discrete and analog combined); switch to extended addressing when the network needs to scale toward the 496-device discrete ceiling, accepting the 10 ms cycle time instead of 5 ms. Because the module carries ATEX\/IECEx Zone 2\/22 and Class I Division 2 approval, it is the module to specify when the AS-i segment itself runs into a hazardous area rather than staying entirely inside a standard enclosure.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAS-Interface network integration for Modicon X80 I\/O architectures — connecting up to 62 discrete or 31 analog AS-i field devices, including AS-i segments that extend into Zone 2\/22 hazardous areas.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230609740059,"sku":"BMXEIA0100","price":408.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-bmxeia0100-modicon-x80-as-i-master-module.jpg?v=1790284014"},{"product_id":"siemens-6es7157-0ac85-0xa0-fdc157-field-device-coupler","title":"Siemens 6ES7157-0AC85-0XA0 SIMATIC NET FDC 157 PROFIBUS PLC Communication Module","description":"\u003cp\u003eThe Siemens 6ES7157-0AC85-0XA0 is the Field Device Coupler FDC 157, a SIMATIC NET PROFIBUS DP to PA \/ Foundation Fieldbus H1 physical-layer coupler with an integrated bus-powered supply of up to 1 A for up to 31 field devices. It runs from 24 V DC, offers redundancy capability, and is rated IP20 for an extended -25 to 60 °C temperature range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7157-0AC85-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField Device Coupler for PROFIBUS PA and Foundation Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, rated (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V (20.4 to 28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains\/Voltage Failure Stored Energy Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS DP Transmission Rate, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.45 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS DP Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin sub D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS PA Transmission Rate, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.25 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connectable Field Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Current Output to Field Devices, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Tested With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Operation, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 x 125 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623404705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe FDC 157 couples a PROFIBUS DP segment at up to 45.45 kbit\/s to a PROFIBUS PA or Foundation Fieldbus H1 segment at 31.25 kbit\/s, so it sits at the transition point where DP-side controllers need to read PA\/FF field instruments without a separate power supply for the field segment - the integrated bus supply feeds up to 31 devices at up to 1 A total. Redundancy capability lets a second coupler back up the same field segment, relevant when the PA-side instruments sit on a process loop that cannot tolerate a single point of failure. IP20 limits mounting to a cabinet or enclosure rather than direct field installation.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePhysical-layer coupling point between a PROFIBUS DP automation network and PROFIBUS PA or Foundation Fieldbus H1 field instruments, such as process transmitters and positioners, mounted inside a control cabinet.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959547486491,"sku":"6ES7157-0AC85-0XA0","price":1508.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-product-image-coming-soon_74cdc955-3bf2-4713-985a-819d36e54c58.png?v=1789640002"},{"product_id":"siemens-6gk1411-1ac00-cloudconnect-cc712-telecontrol-module","title":"Siemens 6GK1411-1AC00 SIMATIC CloudConnect 7 CC712 2x Ethernet MQTT OPC UA Telecontrol Module","description":"\u003cp\u003eThe Siemens 6GK1411-1AC00 SIMATIC CloudConnect 7 CC712 is an IoT gateway that connects programmable controllers to cloud services and OPC UA over 2x RJ45 Industrial Ethernet ports. It reads S7, S7-Plus, OPC UA and Modbus on the field side and publishes via MQTT, HTTP or OPC UA to the cloud, supporting up to 3 active cloud connections and 500 data points per device.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1411-1AC00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622710920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCloudConnect CC712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7, S7-Plus, OPC UA, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCloud\/MES Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMQTT, HTTP, OPC UA (server and client)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45, 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pin terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLP card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (10.8-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA typical at 24 V DC in communication mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, S7-300 rail, S7-1500 rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Cloud Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLower-Level Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Points per Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 1 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOPC UA Server\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 10 client connections, 1500 variables max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOPC UA Client\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 1 server connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb-based diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassword protection for web applications, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTP, NTP (secure), manual setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 °C (vertical), up to 60 °C (horizontal busbars)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 95% at 25 °C, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL Hazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe CC712's single lower-level device limit and 500-data-point ceiling make it a fit for connecting one PLC station to the cloud; a line with several controllers or more than 500 tags needs the CC716's 7-device, 3500-point capacity instead. Its OPC UA server accepts up to 10 client connections against a 1500-variable limit, so the practical ceiling is usually the variable count rather than the connection count. DIN-rail, S7-300 rail, S7-1500 rail and wall mounting are all supported, so it drops into an existing control cabinet without extra hardware.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959670694171,"sku":"6GK1411-1AC00","price":917.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1411-1ac00-cloudconnect-cc712-telecontrol-module.png?v=1789799923"},{"product_id":"siemens-6gk1411-5ac00-cloudconnect-cc716-telecontrol-module","title":"Siemens 6GK1411-5AC00 SIMATIC CloudConnect 7 CC716 2x Ethernet MPI\/PB MQTT OPC UA Telecontrol Module","description":"\u003cp\u003eThe Siemens 6GK1411-5AC00 SIMATIC CloudConnect 7 CC716 is an IoT gateway that connects automation devices to cloud services and OPC UA over 2x RJ45 Industrial Ethernet ports plus one MPI\/PROFIBUS port. It reads S7, S7-Plus, OPC UA and Modbus and publishes via MQTT, HTTP or OPC UA, supporting up to 7 lower-level devices and 3500 data points per device.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1411-5AC00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622716670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCloudConnect CC716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7, S7-Plus, OPC UA, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCloud\/MES Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMQTT, HTTP, OPC UA (server and client)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45, 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMPI\/PROFIBUS Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS 485), 9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 digital input, 1 digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pin terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLP card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (10.8-28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA typical at 24 V DC in communication mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, S7-300 rail, S7-1500 rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Cloud Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLower-Level Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Points per Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 7 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOPC UA Server\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 10 client connections, 4500 variables max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOPC UA Client\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 7 server connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb-based diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassword protection for web applications, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTP, NTP (secure), manual setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 °C (vertical), up to 60 °C (horizontal busbars)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 95% at 25 °C, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL Hazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAgainst the single-device CC712, the CC716 adds an MPI\/PROFIBUS port and raises the lower-level device count to 7 and the data-point ceiling to 3500, so it fits a cell with several PLCs or a mixed Ethernet\/PROFIBUS layout rather than one standalone controller. Its OPC UA server takes up to 10 client connections against a 4500-variable limit, roughly triple the CC712's headroom, which matters more than the port count once tag volume grows.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959691141403,"sku":"6GK1411-5AC00","price":1379.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1411-5ac00-cloudconnect-cc716-telecontrol-module.png?v=1789799936"},{"product_id":"siemens-6gk1561-2aa00-cp-5612-pci","title":"Siemens 6GK1561-2AA00 SIMATIC NET CP 5612 PCI PROFIBUS Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1561-2AA00 CP 5612 is a PCI communications processor card that connects a PG or PC with a PCI bus to PROFIBUS or MPI at 9.6 kbit\/s to 12 Mbit\/s, supported on both 32-bit and 64-bit operating systems. It draws power from the backplane bus (3.3 V at 0.15 A, 12 V at 0.25 A) and presents a single 9-pin Sub-D RS 485 port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1561-2AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 5612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate, PROFIBUS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS 485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI, 32-bit, 3.3V\/5V Universal Key, 33\/66 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 V and 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 A at 3.3 V, 0.25 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master, Devices Operable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,640 bytes in, 14,640 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7\/PG Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 107 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169252478\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe PCI backplane connection fits older or existing PC hardware that has a PCI slot rather than PCI Express, which is the deciding factor against the CP 5622 since both cards offer the same 9.6 kbit\/s to 12 Mbit\/s PROFIBUS range and single RS 485 port. Its 64-device DP master limit and 8 S7\/PG connections suit engineering and diagnostic workstations rather than a production master handling more than 100 DP slaves, where the CP 5623 applies. SOFTNET-PB DP software is required and is not bundled with the card.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnecting an engineering PG or PC with a PCI slot to a PROFIBUS DP or MPI network for programming, diagnostics, or a DP master function within the 64-device limit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959755104539,"sku":"6GK1561-2AA00","price":787.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1561-2aa00-cp-5612-pci.png?v=1789799993"},{"product_id":"siemens-6gk1562-2aa00-cp-5622-pcie","title":"Siemens 6GK1562-2AA00 SIMATIC NET CP 5622 PCIe x1 PROFIBUS Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1562-2AA00 CP 5622 is a PCI Express x1 communications processor card that connects a PG or PC with a PCIe bus to PROFIBUS or MPI at 9.6 kbit\/s to 12 Mbit\/s, supported on both 32-bit and 64-bit operating systems. It draws power from the backplane bus (3.3 V at 0.3 A, 12 V at 0.25 A) and presents a single 9-pin Sub-D RS 485 port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1562-2AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 5622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate, PROFIBUS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS 485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 V and 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 A at 3.3 V, 0.25 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master, Devices Operable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14,640 bytes in, 14,640 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7\/PG Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 112 x 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169252461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe PCI Express x1 edge connector fits current PC hardware where a legacy PCI slot is no longer available, which is the practical reason to choose this card over the CP 5612 - the PROFIBUS performance figures (64 DP devices, 8 S7\/PG connections) are identical between the two. Compared with the CP 5623\/CP 5624, this card has no DP-Base software or configuration tool included, so it suits a PG\/engineering role rather than a standalone DP master station running without STEP 7 or TIA Portal.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnecting an engineering PG or PC with a PCIe slot to a PROFIBUS DP or MPI network for programming, diagnostics, or a DP master function within the 64-device limit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959755170075,"sku":"6GK1562-2AA00","price":739.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1562-2aa00-cp-5622-pcie.png?v=1789800000"},{"product_id":"siemens-6gk1571-1aa00-cp-5711-usb","title":"Siemens 6GK1571-1AA00 SIMATIC NET CP 5711 USB PROFIBUS Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1571-1AA00 CP 5711 is a USB 2.0 communications processor that connects a PG or notebook to PROFIBUS or MPI at 9.6 kbit\/s to 12 Mbit\/s through a 9-pin Sub-D RS 485 port, and ships with a 2 m USB cable. It runs from the USB bus at 5 V\/0.5 A, or from an optional external 18-30 V DC supply drawing up to 0.3 A, and mounts on a 35 mm DIN rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1571-1AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 5711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate, PROFIBUS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS 485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0, Standard-B socket with mechanical interlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, USB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, External (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (18 - 30 V), 0.3 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master, Devices Operable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15,616 bytes in, 15,616 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7\/PG Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 137 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail, optional mounting rail support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169187688\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUSB power from the PC or notebook removes the need for a separate power brick in the field, unlike the PCI\/PCI Express cards in this family which draw power from the backplane bus and cannot be used with a notebook at all. The optional external 24 V DC input is there for setups where USB power alone is not adequate, without losing USB connectivity. Its 64-device DP master limit and 8 S7\/PG connections match the CP 5612\/CP 5622 cards, so it fits an engineering or diagnostic role rather than a fixed 124-device production master.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnecting a service notebook or PG without a free PCI\/PCIe slot to a PROFIBUS DP or MPI network for programming, diagnostics, or a DP master function within the 64-device limit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959758512411,"sku":"6GK1571-1AA00","price":1271.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1571-1aa00-cp-5711-usb.png?v=1789800018"},{"product_id":"siemens-6gk7343-1cx10-0xe0-cp-343-1-lean","title":"Siemens 6GK7343-1CX10-0XE0 SIMATIC NET CP 343-1 Lean PROFINET IO Device PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 343-1 Lean (6GK7343-1CX10-0XE0) is a communications processor that connects a SIMATIC S7-300 CPU to Industrial Ethernet via TCP\/IP and UDP, with an integrated 2-port ERTEC 200 switch and PROFINET IO device support. It handles S7 communication as a server, SEND\/RECEIVE with RFC1006, and fetch\/write over two RJ45 ports at 10...100 Mbit\/s, drawing 24 V DC at 0.16 A typical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7343-1CX10-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 343-1 Lean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole pluggable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (+20% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5V typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (external, 24V typical \/ max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 A \/ 0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Device Data (input \/ output, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 byte \/ 512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (SEND\/RECEIVE, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch \/ Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated 2-port switch, ring redundancy (MRP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical install)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...40 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-300 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 x 125 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs a spare-part Lean variant, this CP covers PROFINET IO device operation with S7 communication and open communication over 8 SEND\/RECEIVE connections - a lighter connection budget than the CP 343-1 Advanced, which adds a PROFINET IO controller role and a Gigabit uplink. Pick the Lean version when the S7-300 station only needs to report into a higher-level PROFINET\/Ethernet network as a device, not act as a controller for its own IO devices.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdds PROFINET IO device and Industrial Ethernet connectivity to S7-300 stations exchanging data with SCADA, MES, or other S7 controllers over TCP\/IP, UDP, or S7 communication.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959820869915,"sku":"6GK7343-1CX10-0XE0","price":1363.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7343-1cx10-0xe0-cp-343-1-lean-communication-module.png?v=1789826088"},{"product_id":"siemens-6gk7343-1ex30-0xe0-cp-343-1-communication-processor","title":"Siemens 6GK7343-1EX30-0XE0 SIMATIC NET CP 343-1 PROFINET IO 2x RJ45 10\/100 Mbit\/s PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 343-1 (6GK7343-1EX30-0XE0) is a communication processor that connects a SIMATIC S7-300 CPU to Industrial Ethernet, offering an integrated 2-port ERTEC 200 switch, 10\/100 Mbit\/s over two RJ45 ports, and support for both PROFINET IO controller and IO device operation. It handles S7 communication, open communication via SEND\/RECEIVE, and multicast, drawing 24 V DC at 0.16 A typical plus 0.2 A from the backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7343-1EX30-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 343-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-300 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Ethernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5 V, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (external, 24 V, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Controller - Max. IO Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical installation, operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 x 125 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC for hazardous zone\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe integrated 2-port switch lets this CP sit inline in a PROFINET line or ring topology without a separate switch, and it can run simultaneously as a PROFINET IO controller for up to 32 IO devices or as an IO device with 512 byte of input and output data - useful where the same station both hosts remote I\/O and reports into a higher-level controller. Choose it over the CP 443-1 series when the backplane is S7-300 rather than S7-400, since the two module formats are not interchangeable.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdds PROFINET\/Industrial Ethernet connectivity, S7 routing, and open communication (SEND\/RECEIVE, multicast) to S7-300 stations in machine and process cells that need to exchange data with SCADA, MES, or other S7 controllers over Ethernet.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959822049563,"sku":"6GK7343-1EX30-0XE0","price":2414.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7343-1ex30-0xe0-cp-343-1-communication-module.png?v=1789681269"},{"product_id":"siemens-6gk7343-1gx31-0xe0-cp-343-1-advanced","title":"Siemens 6GK7343-1GX31-0XE0 SIMATIC NET CP 343-1 Advanced Gigabit PROFINET PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 343-1 Advanced (6GK7343-1GX31-0XE0) is a communications processor that connects a SIMATIC S7-300 CPU to Industrial Ethernet with a Gigabit RJ45 port plus a 2-port 10\/100 Mbit\/s switch, operating as a PROFINET IO controller for up to 128 IO devices or as an IO device with IRT support. It adds PROFINET CBA, firewall\/VPN security, and PROFIenergy, drawing 24 V DC at 0.48 A typical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7343-1GX31-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 343-1 Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (1x Gigabit + 2x switched 10\/100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interface 1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interface 2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5V typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (external, 24V typical \/ max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 A \/ 0.62 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, up to 128 IO devices (128 IRT-capable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET CBA Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (SEND\/RECEIVE, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPSec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Encryption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAES-256, AES-192, AES-128, 3DES-168, DES-56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirewall\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStateful inspection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical install)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...40 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 x 125 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe Gigabit uplink plus a separate 2-port 10\/100 switch let this CP run a high-speed backbone connection alongside a local PROFINET IO line, and its 128-device IO controller capacity with IRT support covers larger S7-300 machine cells than the Lean variant's device-only role. Choose the Advanced module when the station must act as a PROFINET IO controller, needs PROFINET CBA, or requires VPN\/firewall security - the Lean CP covers none of these.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to S7-300 stations acting as a PROFINET IO controller for machine or line segments, or where VPN\/firewall protection and Gigabit backbone connectivity are required alongside PROFINET CBA component-based automation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959822803227,"sku":"6GK7343-1GX31-0XE0","price":3557.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7343-1gx31-0xe0-cp-343-1-advanced-communication-module.png?v=1789826094"},{"product_id":"siemens-6gk7543-1ax00-0xe0-cp-1543-1-communication-processor","title":"Siemens 6GK7543-1AX00-0XE0 SIMATIC S7-1500 CP 1543-1 Gigabit Ethernet PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 1543-1 (6GK7543-1AX00-0XE0) is a communications processor that connects a SIMATIC S7-1500 CPU to Industrial Ethernet over a single Gigabit RJ45 port, supporting TCP\/IP, ISO, UDP, and S7 communication with IPv4\/IPv6 addressing. It adds a stateful-inspection firewall, IPSec VPN, and IEEE 802.1X port authentication, drawing 0.35 A typical from the backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7543-1AX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 1543-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 V (backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 15V typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 \/ Multi-Protocol Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication (T-block) Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFTP Connections (client \/ server, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 \/ 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPSec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Encryption \/ Hashing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAES-256, AES-192, AES-128, 3DES-168, DES-56; MD5, SHA-1, SHA-256, SHA-384, SHA-512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatic IP routing, up to 1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1X (radius), stateful firewall, log file for unauthorized access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical install)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...40 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-1500 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 142 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Units per CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (depending on CPU type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe single Gigabit port plus IEEE 802.1X port authentication and a stateful firewall make this CP suited to S7-1500 stations that sit directly on a plant IT network needing access control, not just PROFINET machine traffic. Choose it over the CM 1542-1 when the station needs VPN, firewall, or 802.1X security rather than baseline PROFINET IO connectivity alone.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits SIMATIC S7-1500 stations that need a secured, routed Ethernet connection into a plant or corporate network - VPN tunneling, IP routing, and 802.1X authentication support IT\/OT convergence requirements.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959823065371,"sku":"6GK7543-1AX00-0XE0","price":2154.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7543-1ax00-0xe0-cp-1543-1-communication-module.png?v=1789826126"},{"product_id":"siemens-6nh3112-0bb00-0xx0-rtu3011c-telecontrol-module","title":"Siemens 6NH3112-0BB00-0XX0 SIMATIC RTU3000C RTU3011C 8DI\/8DO\/4AI GNSS Telecontrol Module","description":"\u003cp\u003eThe Siemens 6NH3112-0BB00-0XX0 SIMATIC RTU3011C is a compact, battery- or solar-powered remote terminal unit with 8 DI, 8 DO and 4 AI onboard, an Industrial Ethernet port and GNSS positioning. It speaks DNP3, IEC 60870-5-104, SINAUT ST7 or MQTT for telecontrol and cloud reporting, and configures through its built-in webserver rather than dedicated engineering software.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-0BB00-0XX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623165651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eRTU3011C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eStandby (Sleep) mode, Actualization mode, Communication mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing \u0026amp; Mounting\u003c\/td\u003e\n\u003ctd\u003eCompact module, 130 x 100 x 75 mm (W x H x D), 35 mm top-hat DIN rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20; IP68 with optional protective housing accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1x Industrial Ethernet, RJ45 port, 10 ... 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003e5-pole pluggable terminal block, 1 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card Slot\u003c\/td\u003e\n\u003ctd\u003e1 slot; SD 1.0, SD 1.1, SDHC or Siemens SMC, max. 32 GiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNSS Antenna Connection\u003c\/td\u003e\n\u003ctd\u003eActive GNSS antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8, pluggable screw terminal block, open-drain transistor or switch, 2-wire; 2 of the 8 usable as counter inputs (min. pulse 0.1 ms, max. 5000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8, pluggable screw terminal block; 4x bistable relay (2-wire) + 4x solid-state relay; output current 300 mA (solid-state 60 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4, pluggable screw terminal block, 2\/3\/4-wire, 12-bit A\/D; parameterizable for 0\/4-20 mA, 0-5\/10 V or Pt1000 -80 ... +140 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless \/ Mobile Connectivity\u003c\/td\u003e\n\u003ctd\u003eVia external IP-based router (no onboard modem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003eDC, 10.8 ... 28.8 V external (12 ... 24 V range); output 12 V or 24 V DC for external devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNSS Antenna Supply\u003c\/td\u003e\n\u003ctd\u003e3.8 V nominal (3.575 V at 5 mA, 3.35 V at 10 mA, 3.125 V at 15 mA), max. 15 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, External 24V DC\u003c\/td\u003e\n\u003ctd\u003eStandby 14 mA, update 35 mA, communication 55 mA (typical, without connected consumers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, Battery 7.2V\u003c\/td\u003e\n\u003ctd\u003eStandby 0.28 mA, update 71 mA, communication 125 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, External 24V DC\u003c\/td\u003e\n\u003ctd\u003eStandby 0.34 W, update 0.85 W, communication 1.25 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, Battery 7.2V\u003c\/td\u003e\n\u003ctd\u003eStandby 0.002 W, update 0.51 W, communication 0.9 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C vertical mounting; -40 ... +70 °C horizontal busbar arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage \/ Transport\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, Max\u003c\/td\u003e\n\u003ctd\u003e95% at 30 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Connectivity\u003c\/td\u003e\n\u003ctd\u003eMQTT; trigger management, time stamping, buffered message frame memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e45 program block types, up to 48 configurable program blocks, 48 digital and 24 analog bit memories max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIT Functions\u003c\/td\u003e\n\u003ctd\u003eFTP client (1 connection, 12-entry buffer); email client (1 connection, 20 addresses \/ 10 user groups max., 20 free texts max. of 160 characters, 12-entry buffer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelecontrol\u003c\/td\u003e\n\u003ctd\u003eSubstation-capable; connects to IEC 60870-5-104, DNP3, SINAUT ST7cc\/sc or TeleControl Server Basic control centers; permanent or demand-oriented connection; max. 256 KiB user data per station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoadable Protocols\u003c\/td\u003e\n\u003ctd\u003eDNP3, IEC 60870-5, SINAUT ST7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection-Loss Buffering\u003c\/td\u003e\n\u003ctd\u003eApprox. 5,000 telegrams (IEC 60870), 10,900 (DNP3), 7,700 (SINAUT ST7), 10,900 (TeleControl Server Basic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeleservice\u003c\/td\u003e\n\u003ctd\u003eRemote firmware update, remote configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eNo configuration software required, via integrated webserver; SIMATIC PDM gateway via Modbus TCP or HART-IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eWeb-based diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN Security\u003c\/td\u003e\n\u003ctd\u003eOpenVPN client, AES-128\/AES-256 encryption, certificate-based authentication, SHA-256 hashing, 2 possible connections (1 simultaneous productive connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Security Functions\u003c\/td\u003e\n\u003ctd\u003ePassword protection for web applications, teleservice and VPN; encrypted data transmission; switch-off of unused services; SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Functions\u003c\/td\u003e\n\u003ctd\u003eNTP support; hardware real-time clock with battery backup, accuracy max. 1.8 s\/day; sync from NTP, GPS, control center, PC or manual setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Detection\u003c\/td\u003e\n\u003ctd\u003eGPS position detection with position data passed to the control center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications, TED-Confirmed\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, cULus, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULHazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 10.8 to 28.8 V DC external input plus a 7.2 V battery mode means this RTU keeps logging and buffering telegrams, up to roughly 10,900 for DNP3 or TeleControl Server Basic, through mains outages without a separate UPS. Two of the eight digital inputs double as 5 kHz counter inputs, so flow or pulse metering does not need a separate counter module. Choose the loadable protocol, DNP3, IEC 60870-5-104, SINAUT ST7 or MQTT, to match the control center already in use, since the unit runs one protocol stack at a time rather than several concurrently; check GNSS national approvals for the installation country before deployment.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959824146715,"sku":"6NH3112-0BB00-0XX0","price":1077.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-0bb00-0xx0-rtu3011c-telecontrol-module.png?v=1790181126"},{"product_id":"siemens-6nh3112-3ba00-1xx2-rtu3000c-battery-housing","title":"Siemens 6NH3112-3BA00-1XX2 SIMATIC RTU3000C Battery Housing for Two Mono Cells Automation Component","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-1XX2 is a battery enclosure for two mono cells, built for the SIMATIC RTU3011C and RTU3030C telecontrol units. Batteries are not included and must be ordered separately per the equipment manual's approved battery type. It connects to the RTU and to a second battery enclosure through two sockets, in a 45 x 100 x 75 mm plastic housing rated IP20.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-1XX2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622242490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eBattery housing for RTU3000C range with autonomous power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Operation\u003c\/td\u003e\n\u003ctd\u003eSuitable for two mono cells; observe the SIMATIC RTU3010C and RTU3030C Equipment Manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrical Connection\u003c\/td\u003e\n\u003ctd\u003eSockets for connecting to SIMATIC RTU3000C and another battery enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHousing: plastic; battery holder: spring steel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C (vertical mounting position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage \/ Transport\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, Max\u003c\/td\u003e\n\u003ctd\u003e95% at 30 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e132 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentification Link\u003c\/td\u003e\n\u003ctd\u003eSupported per IEC 61406-1:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTwo of these enclosures can be chained through the second socket to extend backup runtime beyond a single pair of mono cells, without adding a separate charger or supply module. Because the enclosure only supplies power during outages of the external 10.8 to 28.8 V DC input, the battery type specified in the RTU3010C and RTU3030C equipment manuals must be respected, or the RTU's battery-mode current draw and low-voltage cutoff will not match the cell chemistry.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959825096987,"sku":"6NH3112-3BA00-1XX2","price":207.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-1xx2-rtu3000c-battery-housing.png?v=1790181133"},{"product_id":"siemens-6nh3112-3ba00-1xx3-rtu3000c-aluminum-enclosure-ip68","title":"Siemens 6NH3112-3BA00-1XX3 SIMATIC RTU3000C Aluminum Enclosure IP68 280x230x111mm Automation Component","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-1XX3 is an IP68-rated aluminum enclosure for SIMATIC RTU3000C devices, powder-coated gray (RAL 7001), measuring 280 x 230 x 111 mm. The cover uses pin-Torx screws, and the housing has seven prepared cable bushings plus one for a mobile-radio antenna; cable glands and sealing plugs must be ordered separately. It is rated -40 to +80 degrees C and IP68 for 1 m \/ 24 h.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-1XX3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169855891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eAluminum housing with protection class IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eDegree of protection IP68, 1 m \/ 24 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Operation\u003c\/td\u003e\n\u003ctd\u003eSuitable for devices of the SIMATIC RTU3000C range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eAluminum, powder coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eGray (RAL 7001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage \/ Transport\u003c\/td\u003e\n\u003ctd\u003e-40 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, Max\u003c\/td\u003e\n\u003ctd\u003e95% at 30 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP68, 1 m \/ 24 h; observe the installation instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.395 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Head Design\u003c\/td\u003e\n\u003ctd\u003ePin-Torx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Bushings\u003c\/td\u003e\n\u003ctd\u003e7 prepared bushings plus 1 for a mobile-radio antenna; cable glands and sealing plugs ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation \u0026amp; Torque Note\u003c\/td\u003e\n\u003ctd\u003eCable gland article 6NH3112-3BA00-1XX4: cap nut 5-6 Nm, fittings 3.5-4.5 Nm; sealing plug article 6NH3112-3BA00-1XX5: 2.5-3.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe IP68 rating (1 m \/ 24 h) suits burial-adjacent, flood-prone or wash-down sites where the RTU3000C's own IP20 module housing would not survive; the pin-Torx cover screws deter unauthorized field access to the electronics inside. Seven prepared cable bushings plus one for a mobile-radio antenna cover a mixed I\/O and antenna installation without extra machining, but the cable glands and sealing plugs are ordered separately and must be torqued to the values given in the installation note to keep the IP68 rating intact.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959825457435,"sku":"6NH3112-3BA00-1XX3","price":381.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-1xx3-rtu3000c-aluminum-enclosure.png?v=1790181140"},{"product_id":"siemens-6nh3112-3ba00-1xx4-cable-gland-m16-ip68","title":"Siemens 6NH3112-3BA00-1XX4 SIMATIC Cable Gland M16 IP68 Automation Component","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-1XX4 is an M16 cable gland rated IP68 for 1 m \/ 24 h submersion, built for SIMATIC RTU3000C enclosures. Made from nickel-plated brass, it operates from -40 to +100°C and accepts cable diameters from 4.5 to 10 mm. It mounts on the 6NH3112-3BA00-1XX1 stainless steel and 6NH3112-3BA00-1XX3 aluminum housings and ships in packs of 2 units.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-1XX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCable gland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eM16, for IP68 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP68, 1 m \/ 24 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable For\u003c\/td\u003e\n\u003ctd\u003eStainless steel housing 6NH3112-3BA00-1XX1 and aluminum housing 6NH3112-3BA00-1XX3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eBrass, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e37.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e27.7 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e4.5 to 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Torque\u003c\/td\u003e\n\u003ctd\u003eCap nut 5-6 Nm, connection piece 3.4-4.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e2 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959825785115,"sku":"6NH3112-3BA00-1XX4","price":20.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-1xx4-cable-gland-m16-ip68.png?v=1790181147"},{"product_id":"siemens-6nh3112-3ba00-1xx5-sealing-plug-m16-ip68","title":"Siemens 6NH3112-3BA00-1XX5 SIMATIC Sealing Plug M16 IP68 Automation Component","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-1XX5 is an M16 sealing plug rated IP68 for 1 m \/ 24 h submersion, closing unused cable entries on SIMATIC RTU3000C enclosures. Made from nickel-plated brass, it measures 18 mm in diameter by 8 mm long, weighs 5.48 g, and operates from -40 to +100°C. It fits the 6NH3112-3BA00-1XX1 stainless steel and 6NH3112-3BA00-1XX3 aluminum housings and ships in packs of 2 units.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-1XX5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eClosing plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eM16, for IP68 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP68, 1 m \/ 24 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable For\u003c\/td\u003e\n\u003ctd\u003eStainless steel housing 6NH3112-3BA00-1XX1 and aluminum housing 6NH3112-3BA00-1XX3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eBrass, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Torque\u003c\/td\u003e\n\u003ctd\u003eHand-tight using tool, approx. 2.5-3.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e2 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959826964763,"sku":"6NH3112-3BA00-1XX5","price":14.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-1xx5-sealing-plug-m16-ip68.png?v=1790181153"},{"product_id":"siemens-6nh3112-3ba00-1xx6-battery-expansion-enclosure","title":"Siemens 6NH3112-3BA00-1XX6 SIMATIC Battery Expansion Enclosure RTU3000C Automation Component","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-1XX6 is a battery expansion enclosure that adds two mono-cell battery positions to the SIMATIC RTU3000C family for autonomous power supply. Its plastic housing uses spring-steel, nickel-plated battery holders, carries an IP20 rating, and operates from -40 to +60°C in vertical mounting. Two sockets connect it to the RTU3000C and to a second battery enclosure; batteries are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-1XX6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBattery housing extension for RTU3000C range with autonomous power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability\u003c\/td\u003e\n\u003ctd\u003eTwo mono cells; observe RTU3010C and RTU3030C Equipment Manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e2, sockets for RTU3000C and another battery enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHousing: plastic. Battery holder: spring steel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Vertical Mounting \/ Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (at 30°C, non-condensing, max)\u003c\/td\u003e\n\u003ctd\u003e95 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eCompact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentification Link\u003c\/td\u003e\n\u003ctd\u003eSupported, acc. to IEC 61406-1:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe enclosure extends battery standby capacity for RTU3000C remote and telecontrol installations that run without a continuous mains supply.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959827521819,"sku":"6NH3112-3BA00-1XX6","price":207.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-1xx6-battery-expansion-enclosure.png?v=1790181159"},{"product_id":"siemens-6nh3112-3ba00-6xx1-hart-rs485-extension-board","title":"Siemens 6NH3112-3BA00-6XX1 SIMATIC RTU3000C HART\/RS485 Extension Board Telecontrol Module","description":"\u003cp\u003eThe Siemens 6NH3112-3BA00-6XX1 is a plug-in extension board that adds HART and RS485 connectivity to the SIMATIC RTU3000C family, linking up to 16 Modbus RTU devices or 16 HART devices in multidrop mode for up to 32 variables. It transfers Modbus RTU data at 9600 to 115200 bit\/s and HART at 1200 bit\/s, draws power internally from the RTU, and operates from -40 to +60 °C in vertical or -40 to +70 °C in horizontal installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-3BA00-6XX1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension Board HART\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnected Devices\u003c\/td\u003e\n\u003ctd\u003e16 Modbus RTU devices or 16 HART devices in multidrop mode, max. 32 variables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e9600 to 115200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e1200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connection\u003c\/td\u003e\n\u003ctd\u003e6-pin plug-in terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal, via RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, External Devices\u003c\/td\u003e\n\u003ctd\u003eDC 12 V or 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Current\u003c\/td\u003e\n\u003ctd\u003e300 mA, limiting continuous current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Vertical Installation \/ Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Horizontal Installation \/ Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (at 30°C, non-condensing, max)\u003c\/td\u003e\n\u003ctd\u003e95 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20; IP68 with protective housing (see accessories)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003ePlug-in module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e62 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e21 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.022 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. RS485 Wire Length\u003c\/td\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, HART (Multidrop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Master Address Range\u003c\/td\u003e\n\u003ctd\u003e0 to 63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus RTU Master Address Range\u003c\/td\u003e\n\u003ctd\u003e1 to 247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eNot required as a separate tool; configured via RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb-Based Diagnostics\u003c\/td\u003e\n\u003ctd\u003eYes, over RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAdd the 6NH3112-3BA00-6XX1 when a low-power RTU3000C needs multidrop field wiring instead of point-to-point runs: one 6-pin terminal strip serves up to 16 Modbus RTU or 16 HART instruments, and the board draws its power from the RTU itself rather than a separate supply. Its ATEX, IECEx, ULhazloc, CCC, and FM approvals let it go into the same hazardous-location installations as the RTU3000C base unit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959828242715,"sku":"6NH3112-3BA00-6XX1","price":273.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-3ba00-6xx1-hart-rs485-extension-board.png?v=1790181166"},{"product_id":"siemens-6nh3112-5bb00-0xx0-rtu3051c-telecontrol-module","title":"Siemens 6NH3112-5BB00-0XX0 SIMATIC RTU3051C LTE-M\/NB-IoT Compact RTU Telecontrol Module","description":"\u003cp\u003eThe Siemens 6NH3112-5BB00-0XX0 SIMATIC RTU3051C is a compact, battery- or solar-powered remote terminal unit with an integrated LTE-M\/NB-IoT modem, a GNSS receiver, and 8 DI \/ 8 DO \/ 4 AI onboard I\/O. It connects to TeleControl Server Basic and supports DNP3, IEC 60870-5-104, SINAUT ST7, or MQTT, runs from 10.8 to 28.8 V DC, and operates from -40 to +60°C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-5BB00-0XX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTU3051C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eStandby (sleep), actualization, communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Ethernet\u003c\/td\u003e\n\u003ctd\u003e1x RJ45 port, 10 to 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAntenna Connections\u003c\/td\u003e\n\u003ctd\u003e2x SMA socket (50 ohms), for mobile wireless and active GNSS antennas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connection\u003c\/td\u003e\n\u003ctd\u003e5-pole pluggable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIM Card Slot\u003c\/td\u003e\n\u003ctd\u003e1x Mini SIM, Micro SIM with adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card Slot\u003c\/td\u003e\n\u003ctd\u003e1x, SD 1.0, SD 1.1, SDHC, Siemens SMC, up to 32 GiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8, pluggable screw terminal block, open-drain transistor or switch, 2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Inputs\u003c\/td\u003e\n\u003ctd\u003e2, max. pulse frequency 5000 Hz, min. pulse duration 0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8: 4x bistable relay (2-wire) and 4x solid-state relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Current\u003c\/td\u003e\n\u003ctd\u003e300 mA, limiting continuous current (60 mA with solid-state relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4, 12-bit, 2-\/3-\/4-wire, 0\/4-20 mA, 0-5\/10 V, or Pt1000 -80 to +140°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Services\u003c\/td\u003e\n\u003ctd\u003eSMS, GPRS, LTE-M, NB-IoT, GSM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGSM Operating Frequency\u003c\/td\u003e\n\u003ctd\u003e850 MHz, 900 MHz, 1800 MHz, 1900 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLTE-M Transfer Rate\u003c\/td\u003e\n\u003ctd\u003eup to 588 kbit\/s downlink, 1000 kbit\/s uplink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNB-IoT Transfer Rate\u003c\/td\u003e\n\u003ctd\u003eup to 120 kbit\/s downlink, 160 kbit\/s uplink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage, External\u003c\/td\u003e\n\u003ctd\u003e10.8 to 28.8 V DC (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumed Current (24 V DC, communication mode, typical)\u003c\/td\u003e\n\u003ctd\u003e83 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (24 V DC, communication mode, typical)\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Vertical Installation \/ Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (at 30°C, non-condensing, max)\u003c\/td\u003e\n\u003ctd\u003e95 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20; IP68 with protective housing (see accessories)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eCompact module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN\u003c\/td\u003e\n\u003ctd\u003eOpenVPN client, AES-128\/AES-256 encryption, SHA-256 hashing, certificate-based authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VPN Connections\u003c\/td\u003e\n\u003ctd\u003e2 (one simultaneous productive connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelecontrol Protocols\u003c\/td\u003e\n\u003ctd\u003eDNP3, IEC 60870-5-104, SINAUT ST7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Center Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60870-5-104, DNP3-capable control centers, SINAUT ST7cc\/sc, ST7 ScadaConnect, TeleControl Server Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Buffering on Connection Loss\u003c\/td\u003e\n\u003ctd\u003eapprox. 5,000 (IEC 60870), 10,900 (DNP3), 7,700 (SINAUT ST7), 10,900 (TeleControl Server Basic) telegrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. User Data per Station\u003c\/td\u003e\n\u003ctd\u003e256 KiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Connectivity\u003c\/td\u003e\n\u003ctd\u003eMQTT supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the RTU3051C over a modular RTU3000C base plus a separate communication board when the application needs an integrated cellular and GNSS remote terminal unit with onboard I\/O in one enclosure: its 8 DI \/ 8 DO \/ 4 AI cover typical substation or pipeline monitoring points without extra I\/O modules, and the dual power path, 10.8 to 28.8 V DC external or battery, suits unmanned or solar-powered sites. The OpenVPN client with AES-256 and certificate-based authentication secures the link back to TeleControl Server Basic without additional hardware.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959829061915,"sku":"6NH3112-5BB00-0XX0","price":1561.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-5bb00-0xx0-rtu3051c-telecontrol-module.png?v=1790181172"},{"product_id":"siemens-6es7137-6ea00-0ba0-et200sp-cm-can","title":"Siemens 6ES7137-6EA00-0BA0 SIMATIC ET 200SP CM CAN Gateway CANopen PLC Communication Module","description":"\u003cp\u003eThe Siemens 6ES7137-6EA00-0BA0 is a SIMATIC ET 200SP communication module, CM CAN, that acts as a gateway to CAN 2.0A\/B and CANopen networks, working as CANopen Manager or Slave per CiA 301\/302. It transmits at up to 1,000 kbit\/s to as many as 60 devices, with IP20 protection and 500 V AC isolation between the backplane bus and the interface.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7137-6EA00-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM 1x CAN ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsable BaseUnits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN according to CiA 303-1, isolated (500 V AC \/ 707 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAN Operating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAN Standard 2.0A\/B, CANopen Manager\/Slave per CiA 301 and 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kbit\/s to 1,000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Number of Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of SDOs, Parallel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of PDOs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128, send\/receive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode\/life-guarding, heartbeat, SYNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Space, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V, 19.2-28.8 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 C to 60 C horizontal, -30 C to 50 C vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth x Height x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 73 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.032 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 60-device limit and 128-PDO capacity size the 6ES7137-6EA00-0BA0 for a mid-sized CAN or CANopen segment integrated into an ET 200SP station rather than a large standalone CAN network. Its dual CANopen Manager\/Slave capability per CiA 301\/302 means the same module can either host the CAN segment from the S7-1200\/S7-1500 side or act as a CANopen node on a larger master network, avoiding a separate protocol converter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960499331355,"sku":"6ES7137-6EA00-0BA0","price":386.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7137-6ea00-0ba0-et200sp-cm-can-module.png?v=1789780720"},{"product_id":"siemens-6es7440-1cs00-0ye0-cp-440-1-comm-module","title":"Siemens 6ES7440-1CS00-0YE0 SIMATIC S7-400 CP 440-1 1-Channel Point-to-Point Comm Module","description":"\u003cp\u003eThe Siemens 6ES7440-1CS00-0YE0 is a SIMATIC S7-400 CP 440-1 coupling module for point-to-point connections, with 1 serial interface running at up to 115.2 kbit\/s. It ships with the STEP 7 configuration package on CD and supports the 3964(R) and ASCII protocol drivers for connecting third-party serial devices to the S7-400.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7440-1CS00-0YE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 440-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Drivers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3964(R), ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate (RS 422\/485)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7, own parameter assignment forms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current from Backplane Bus 5 V DC (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Requirement per Interface (S7-CPU card)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5 Kbytes for parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe CP 440-1 carries a single serial interface, so it fits racks that need one point-to-point link to a barcode reader or third-party serial device without dedicating a slot to a multi-channel module. Where an application needs a second independent serial link, a multi-channel coupling module in the same family is the better fit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eA single 115.2 kbit\/s serial link covers point-to-point connections to barcode scanners or third-party controllers that speak the 3964(R) or ASCII protocol rather than PROFIBUS or Industrial Ethernet. The STEP 7 configuration package handles the parameter assignment for the interface without custom driver code.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960604418331,"sku":"6ES7440-1CS00-0YE0","price":1768.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7440-1cs00-0ye0-cp-440-1-communication-module.png?v=1789797993"},{"product_id":"siemens-6es7441-1aa05-0ae0-cp-441-1-comm-module","title":"Siemens 6ES7441-1AA05-0AE0 SIMATIC S7-400 CP 441-1 1-Channel Point-to-Point Comm Module","description":"\u003cp\u003eThe Siemens 6ES7441-1AA05-0AE0 is a SIMATIC S7-400 CP 441-1 coupling module for point-to-point connections, with 1 variable interface configurable as 20 mA TTY, RS 422\/485, or RS 232 at up to 115.2 kbit\/s. It supports the 3964(R), ASCII, and printer protocol drivers, including direct output to HP-Deskjet, HP-Laserjet, and IBM-Proprinter devices.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7441-1AA05-0AE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 441-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Drivers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3964(R), ASCII, Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Printers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, RS 422\/485 (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, RS 232 (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, 20 mA TTY (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoint-to-Point Transmission Rate (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s (min. 300 bps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current from Backplane Bus 5 V DC (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA (without interface module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W (incl. 1x 20 mA TTY module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 g (interface modules: 80 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe CP 441-1 interface is variable rather than fixed, so the same module serves TTY, RS 422\/485, or RS 232 links depending on which interface module is fitted, instead of committing to one electrical standard at order time. The built-in printer protocol driver removes the need for a separate print-formatting program when the point-to-point link feeds a report printer rather than another controller. For a second independent serial channel on one module, a 2-channel coupling module in the same family is the better fit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe variable interface and 3964(R)\/ASCII\/printer protocol support cover point-to-point links to third-party serial controllers, barcode scanners, and report printers from an S7-400 rack, wherever the field device predates PROFIBUS or Ethernet connectivity.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960604614939,"sku":"6ES7441-1AA05-0AE0","price":1182.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7441-1aa05-0ae0-cp-441-1-communication-module.png?v=1789797999"},{"product_id":"siemens-6es7441-2aa05-0ae0-cp-441-2-comm-module","title":"Siemens 6ES7441-2AA05-0AE0 SIMATIC S7-400 CP 441-2 2-Channel Point-to-Point Comm Module","description":"\u003cp\u003eThe Siemens 6ES7441-2AA05-0AE0 is a SIMATIC S7-400 CP 441-2 coupling module for point-to-point connections, with 2 variable interfaces each configurable as 20 mA TTY, RS 422\/485, or RS 232 at up to 115.2 kbit\/s. It adds the RK 512 protocol driver on top of 3964(R), ASCII, and printer support, letting two independent serial links run from one module slot.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7441-2AA05-0AE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 441-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Drivers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3964(R), ASCII, RK 512, Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Printers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, RS 422\/485 (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, RS 232 (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, 20 mA TTY (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoint-to-Point Transmission Rate (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s (min. 300 bps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current from Backplane Bus 5 V DC (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA (without interface module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 W (incl. 2x 20 mA TTY module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 g (interface modules: 80 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the CP 441-2 over the single-interface variant in the same family when the application needs two independent point-to-point links, or specifically the RK 512 protocol, on one module slot rather than dedicating two slots to single-channel modules. Each of its two interfaces is separately variable between TTY, RS 422\/485, and RS 232, so the two links do not have to share the same electrical standard.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTwo independently configurable serial channels with 3964(R), ASCII, RK 512, and printer protocol support suit racks that must talk to two separate third-party serial devices, such as a host computer over RK 512 and a report printer, from a single S7-400 slot.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960604844315,"sku":"6ES7441-2AA05-0AE0","price":2697.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7441-2aa05-0ae0-cp-441-2-communication-module.png?v=1789798004"},{"product_id":"siemens-6es7540-1ab00-0aa0-cm-ptp-rs422-485-ba","title":"Siemens 6ES7540-1AB00-0AA0 SIMATIC S7-1500 CM PtP RS422\/485 BA 19.2kbit\/s PLC Communication Module","description":"\u003cp\u003eThe Siemens 6ES7540-1AB00-0AA0 is a SIMATIC S7-1500 point-to-point communication module, type CM PtP RS422\/485 BA, providing an RS422\/RS485 serial interface on a 15-pin D-sub socket. It transmits at up to 19.2 kbit\/s over cable runs up to 1 200 m and supports Freeport, 3964(R), and USS protocols for connecting third-party serial devices.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7540-1AB00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515079934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eCM PtP RS422\/485 BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS422 \/ RS485, 15-pin D-sub socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate, max. (RS485 \/ RS422)\u003c\/td\u003e\n\u003ctd\u003e19.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, max.\u003c\/td\u003e\n\u003ctd\u003e1 200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols supported\u003c\/td\u003e\n\u003ctd\u003eFreeport, 3964(R), USS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelegram length, max.\u003c\/td\u003e\n\u003ctd\u003e1 kbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelegram buffer\u003c\/td\u003e\n\u003ctd\u003e2 kbyte, up to 255 buffered telegrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption, rated (backplane bus)\u003c\/td\u003e\n\u003ctd\u003e43 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption from backplane bus\u003c\/td\u003e\n\u003ctd\u003e0.65 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degrees C (horizontal), 0 to 40 degrees C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUSS protocol support lets this module poll Siemens drives (such as MICROMASTER or SINAMICS units with USS interfaces) directly over RS485 without a PROFIBUS or PROFINET gateway, which is the main reason to pick a CM PtP module over a fieldbus communication module for small serial-drive networks. Freeport mode gives the user program full control of the telegram format for connecting non-Siemens serial instruments (scales, barcode readers, third-party controllers), while 3964(R) provides a fixed handshake protocol for point-to-point links to other SIMATIC controllers. At 19.2 kbit\/s and 1 200 m maximum cable length, throughput is adequate for polling or parameter read\/write but not for high-speed data acquisition.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSerial point-to-point links to third-party instrumentation, barcode scanners, or older SIMATIC S7-300\/S7-400\/S7-1500 stations, and USS-based polling of Siemens drives without a fieldbus network.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960655143195,"sku":"6ES7540-1AB00-0AA0","price":674.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7540-1ab00-0aa0-cm-ptp-rs422-485-ba.png?v=1789714777"},{"product_id":"siemens-6es7540-1ad00-0aa0-cm-ptp-rs232-ba-comm-module","title":"Siemens 6ES7540-1AD00-0AA0 SIMATIC S7-1500 CM PtP RS232 BA 19.2 kbit\/s Communication Module","description":"\u003cp\u003eThe Siemens 6ES7540-1AD00-0AA0 is a SIMATIC S7-1500 CM PtP RS232 BA point-to-point communication module for serial RS232 connections up to 19.2 kbit\/s, supporting Freeport, 3964(R), and USS protocols through a 9-pin D-sub connector. It draws 50 mA from the backplane bus, consumes 0.75 W, and mounts directly on the S7-1500 rail alongside the CPU.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7540-1AD00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM PtP RS 232 BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, 9-pin D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFreeport, 3964(R), USS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS232 Auxiliary Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS, CTS, DTR, DSR, RI, DCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreeport Telegram Length, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3964(R) Telegram Length, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelegram Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kbyte, 255 telegrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 W from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test), between backplane bus and interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 mounting rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V12 or higher, STEP 7 V5.5 SP2 with GSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA designation caps transmission at 19.2 kbit\/s, a fraction of what faster modules in the same CM PtP family support: adequate for USS drive telegrams and slow Freeport links, but a bottleneck for high-throughput 3964(R) transfers. Choose this module when the connected RS232 device, such as a legacy sensor, printer, or USS-interface drive, does not exceed 19.2 kbit\/s; links needing higher throughput or RS422\/RS485 wiring call for a different module in the lineup. The 707 V DC-tested isolation between the backplane bus and interface protects the CPU side from field-side transients on the RS232 line.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSerial point-to-point links to legacy RS232 field devices on an S7-1500 station, including metering equipment, badge printers, and USS-protocol drives that communicate below 19.2 kbit\/s. The 9-pin D-sub connector and RTS\/CTS\/DTR\/DSR\/RI\/DCD auxiliary signal support match standard RS232 cabling without an adapter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960655339803,"sku":"6ES7540-1AD00-0AA0","price":507.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7540-1ad00-0aa0-cm-ptp-rs232-ba-comm-module.png?v=1789798283"},{"product_id":"siemens-6es7541-1ab00-0ab0-cm-ptp-rs422-485-hf-comm-module","title":"Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422\/485 HF 115.2 kbit\/s Communication Module","description":"\u003cp\u003eThe Siemens 6ES7541-1AB00-0AB0 is a SIMATIC S7-1500 CM PtP RS422\/485 HF point-to-point communication module for RS422 and RS485 serial links up to 115.2 kbit\/s over a 15-pin D-sub socket, supporting Freeport, 3964(R), USS, and Modbus RTU master\/slave protocols. It draws 43 mA from the backplane bus and mounts directly on the S7-1500 rail alongside the CPU.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7541-1AB00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM PtP RS 422 \/ 485 HF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422, RS485, 15-pin D-sub socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, max. (RS485)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, max. (RS422)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS422 4-Wire Full Duplex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFreeport, 3964(R), USS, Modbus RTU master\/slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModbus RTU Master Address Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 247, extended 1 to 65535; max. 32 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModbus RTU Device Address Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 247, extended 1 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelegram Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kbyte, 255 telegrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43 mA from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65 W from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test), between backplane bus and interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 mounting rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V12 or higher, STEP 7 V5.5 SP2 with GSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.268 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe HF designation supports 115.2 kbit\/s over RS422 or RS485, well above the throughput of the base-level PtP modules in the same product line, and the 4-wire full-duplex RS422 wiring together with RS485 multidrop lets one module reach up to 1 200 m of cable. Modbus RTU master mode addresses up to 32 devices, 1 to 247 with extended addressing to 65535, so this module fits multidrop RS485 networks of Modbus field instruments where a single RS232 point-to-point link would not scale. The 8 kbyte telegram buffer holds more queued 3964(R) or Freeport frames during bursts than a smaller-buffer module handles.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMultidrop RS485 sensor and actuator networks, Modbus RTU polling of drives or metering devices, and long-distance RS422 links between control cabinets up to 1 200 m, all addressed through the S7-1500 backplane without a separate gateway.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960655536411,"sku":"6ES7541-1AB00-0AB0","price":1020.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7541-1ab00-0ab0-cm-ptp-rs422-485-hf-comm-module.png?v=1789798291"},{"product_id":"siemens-6es7541-1ad00-0ab0-cm-ptp-rs232-hf-comm-module","title":"Siemens 6ES7541-1AD00-0AB0 SIMATIC S7-1500 CM PtP RS232 HF 115.2 kbit\/s Communication Module","description":"\u003cp\u003eThe Siemens 6ES7541-1AD00-0AB0 is a SIMATIC S7-1500 CM PtP RS232 HF point-to-point communication module for RS232 serial connections up to 115.2 kbit\/s through a 9-pin D-sub connector, supporting Freeport, 3964(R), USS, and Modbus RTU master or device operation. It draws 50 mA from the backplane bus and mounts directly on the S7-1500 rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7541-1AD00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM PtP RS 232 HF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, 9-pin D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115.2 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS232 Auxiliary Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS, CTS, DTR, DSR, RI, DCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFreeport, 3964(R), USS, Modbus RTU master\/device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModbus RTU Master Address Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 247, extended 1 to 65535; max. 1 device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModbus RTU Device Address Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 247, extended 1 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelegram Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kbyte, 255 telegrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 W from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test), between backplane bus and interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 mounting rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V12 or higher, STEP 7 V5.5 SP2 with GSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.259 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe HF designation raises RS232 throughput to 115.2 kbit\/s and adds Modbus RTU master or device operation with an 8 kbyte telegram buffer, well beyond a base RS232 PtP module's lower baud rate and smaller buffer. Modbus RTU master mode on this module addresses a single device only, 1 to 247 with extended addressing to 65535, so it suits a dedicated point-to-point Modbus link rather than a multidrop network; multidrop or long-distance wiring needs an RS422\/RS485 interface module instead. The 15 m RS232 cable limit keeps this module tied to devices mounted close to the control cabinet.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePoint-to-point RS232 links at 115.2 kbit\/s to a single nearby device, such as a Modbus RTU-capable drive, barcode scanner, or operator terminal within 15 m of the S7-1500 station, using Freeport or 3964(R) framing where Modbus is not required.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960655733019,"sku":"6ES7541-1AD00-0AB0","price":1098.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7541-1ad00-0ab0-cm-ptp-rs232-hf-comm-module.png?v=1789798297"},{"product_id":"siemens-6es7545-5da00-0ab0-cm-profibus-dp","title":"Siemens 6ES7545-5DA00-0AB0 SIMATIC ET 200SP CM PROFIBUS DP 125-Slave PLC Communication Module","description":"\u003cp\u003eThe Siemens 6ES7545-5DA00-0AB0 is a SIMATIC ET 200SP communication module, type CM PROFIBUS DP, that plugs onto an ET 200SP CPU to add a PROFIBUS DP interface on a 9-pin D-sub socket. It can operate as a DP master for up to 125 DP slaves or as a DP slave itself, at transmission rates up to 12 Mbit\/s with automatic baud rate detection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7545-5DA00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623404538\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eCM PROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware \/ HW functional status\u003c\/td\u003e\n\u003ctd\u003eFS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS485, 9-pin D-sub socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, permissible range 19.2 to 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS DP master, max. slaves\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate, max.\u003c\/td\u003e\n\u003ctd\u003e12 Mbit\/s, automatic baud rate search\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress area, max. (DP device)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser data per address area, max.\u003c\/td\u003e\n\u003ctd\u003e128 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer memory, inputs \/ outputs\u003c\/td\u003e\n\u003ctd\u003e244 byte \/ 244 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, max. (RS485)\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 degrees C (horizontal), -25 to 50 degrees C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 117 x 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSupporting up to 125 DP slaves as a master, this module handles a full PROFIBUS DP segment from a single ET 200SP station, which is the reason to add it rather than route legacy PROFIBUS devices through a separate gateway. It can also run as a DP slave, so an ET 200SP station built around this CPU module can itself be integrated as a remote node on an existing PROFIBUS master system during a migration to PROFINET. The 244-byte input and 244-byte output transfer memory and 128-byte-per-address-area limit set the ceiling on how much process data can move per DP cycle; large legacy DP installations should check these limits against total connected slave data before specifying this module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdding PROFIBUS DP master or slave capability to an ET 200SP CPU for integrating legacy PROFIBUS drives, sensors, or remote I\/O during a phased migration to PROFINET.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960655929627,"sku":"6ES7545-5DA00-0AB0","price":548.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7545-5da00-0ab0-cm-profibus-dp.png?v=1789714783"},{"product_id":"siemens-6es7547-1jf00-0ab0-cm-8xio-link-master-module","title":"Siemens 6ES7547-1JF00-0AB0 SIMATIC S7-1500 CM 8xIO-Link 8-Port IO-Link Master Communication Module","description":"\u003cp\u003eThe Siemens 6ES7547-1JF00-0AB0 is a SIMATIC S7-1500 CM 8xIO-Link communication module, an 8-port IO-Link V1.1 master supporting IO-Link protocols 1.0 and 1.1 with up to 8 ports simultaneously controllable. It runs on 24 V DC, 20.4 to 28.8 V, delivers 1 A per port with 4 A total current per module, and mounts directly on the S7-1500 rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7547-1JF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM 8xIO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV1.0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO-Link, digital input (DI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, permissible range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA, without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIO-Link Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, all simultaneously controllable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIO-Link Protocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO-Link 1.0, IO-Link 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle Time, min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Input per Port, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Input per Module, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Output per Port, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Output per Module, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Parameter Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kbyte per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaster Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration without S7-PCT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, unshielded, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A; Type B with 24 V DC via external terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A per port, 4 A total current per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per channel, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption from Backplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 degC, observe derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 40 degC, observe derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test), between channels and backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 mounting rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V15.1 with HSP 274 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.302 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAll 8 IO-Link ports are simultaneously controllable at a 2 ms minimum cycle time, so a fully populated module updates every port without a scan-time penalty for using more channels. Each port carries 1 A, 4 A total per module, enough for most IO-Link sensors and small pneumatic valve terminals but a figure worth checking against actuator inrush current on multi-actuator ports. Master backup stores IO-Link device configurations on the module itself, so a failed sensor can be swapped without re-downloading parameters from the CPU. Ports left unused for IO-Link communication can be parameterized as plain 24 V digital inputs instead.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnecting IO-Link V1.1 sensors and actuators, photoelectric sensors, pressure switches, and small valve terminals directly to the S7-1500 backplane without a separate fieldbus gateway, with per-port diagnostics for wire break, short-circuit, and supply voltage monitoring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960656126235,"sku":"6ES7547-1JF00-0AB0","price":693.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7547-1jf00-0ab0-cm-8xio-link-master-module.png?v=1789798303"},{"product_id":"siemens-6gk1162-3aa00-cp-1623-communication-processor-card","title":"Siemens 6GK1162-3AA00 SIMATIC NET CP 1623 PCI Express Industrial Ethernet Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1162-3AA00 CP 1623 is a PCI Express x1 communication processor card that connects a PC station to Industrial Ethernet at 10\/100\/1000 Mbit\/s through its onboard 2-port RJ45 switch. It supports S7 communication, open communication via SEND\/RECEIVE, and PROFINET CBA, and up to 4 of these cards can be installed in a single PC station.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1162-3AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169160506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 1623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Ethernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Bus Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 V and 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (10.5-32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current from Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85 A at 3.3 V, 0.4 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current from External Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 A at 24 V, 0.55 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.6 W (7.2 W in switch mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1, half length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 111 x 167 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Cards per PC Station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication (SEND\/RECEIVE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 120 connections, requires HARDNET-IE S7 (S7-1613)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 120 connections (40 optimized), requires HARDNET-IE S7 (S7-1613)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 active \/ 207 configurable connections per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET CBA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 228 remote connection partners, 10000 connections total, requires PN CBA OPC server \/ SIMATIC iMAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, integrated 2-port switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHARDNET-IE S7-REDCONNECT for SIMATIC S7 H systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSICLOCK Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP v1, DCP, MIB (I\u0026amp;M0, I\u0026amp;M1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ... 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 95% at 25 °C, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eFour CP 1623 cards can run in one PC station, so a system needing more than 120 S7 connections or more Industrial Ethernet segments scales by adding cards rather than switching to a different processor. The onboard 2-port switch lets the card sit inline on a ring or line topology without a separate external switch, and PROFINET CBA support (up to 10,000 connections total) makes it the fit for PC-based component-based automation rather than pure S7\/open communication setups.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960699478299,"sku":"6GK1162-3AA00","price":2080.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1162-3aa00-cp-1623-communication-processor-card.png?v=1789799917"},{"product_id":"siemens-6gk1562-3aa00-cp-5623-pcie","title":"Siemens 6GK1562-3AA00 SIMATIC NET CP 5623 PCIe x1 PROFIBUS Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1562-3AA00 CP 5623 is a PCI Express x1 (3.3 V) communications processor for PROFIBUS, supplied with a configuration tool and DP-Base software including a DP-RAM interface, PG protocol, and FDL protocol as a single-installation runtime license, class A. It operates as a DP master for up to 124 devices with a 30,256-byte input and output address range.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1562-3AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 5623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate, PROFIBUS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS 485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1, half length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 V and 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.72 A at 3.3 V, 0.25 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master, Devices Operable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,256 bytes in, 30,256 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Services, Master\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPV0, DPV1, DPV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFMS Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7\/PG Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCards per PC Station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 112 x 168 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169188609\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eDP-Base software and the configuration tool ship with the card, so it operates as a standalone DP master without a separate SOFTNET-PB license, unlike the CP 5612\/CP 5622. The 124-device DP master capacity and 30,256-byte I\/O range are roughly double the CP 5612\/CP 5622 figures, matching it to a production master with more slaves than an engineering PG needs. DPV2 support adds isochronous and slave-to-slave data exchange, which DPV0\/DPV1-only cards in this family do not offer. Choose the CP 5624 instead when both a master and a device connection are needed on the same PC.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eStandalone PROFIBUS DP master stations running more than 64 slave devices, and applications needing DPV2 isochronous or slave-to-slave communication without additional master software.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960699511067,"sku":"6GK1562-3AA00","price":1368.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1562-3aa00-cp-5623-pcie.png?v=1789800005"},{"product_id":"siemens-6gk1562-4aa00-cp-5624-pcie","title":"Siemens 6GK1562-4AA00 SIMATIC NET CP 5624 PCIe x1 Dual-Port PROFIBUS Communication Processor Card","description":"\u003cp\u003eThe Siemens 6GK1562-4AA00 CP 5624 is a PCI Express x1 (3.3 V) communications processor with both a DP master and a DP device connection to PROFIBUS on two separate 9-pin Sub-D ports, supplied with a configuration tool and DP-Base software including a DP-RAM interface, PG protocol, and FDL protocol as a single-installation runtime license, class A.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1562-4AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 5624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate, PROFIBUS (both ports)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 9-pin Sub-D socket (RS 485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1, half length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 V and 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 A at 3.3 V, 0.3 A at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master, Devices Operable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,256 bytes in, 30,256 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Device I\/O Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244 bytes in, 244 bytes out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Services, Master\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPV0, DPV1, DPV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFMS Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7\/PG Connections, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207 per PC station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCards per PC Station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 x 112 x 168 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169188593\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe second RS 485 port is the reason to pick this card over the single-port CP 5623: it runs an independent DP master on one port and a DP device connection (244-byte I\/O) on the other, from the same PC. Master capacity and DPV0\/DPV1\/DPV2 support match the CP 5623 exactly, so choose this card specifically when the PC also needs to appear as a slave on a second PROFIBUS network rather than only mastering one.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePC stations that both master a PROFIBUS DP network and act as a DP device on a separate PROFIBUS segment, such as a gateway or supervisory PC bridging two independent bus systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960699576603,"sku":"6GK1562-4AA00","price":2142.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1562-4aa00-cp-5624-pcie.png?v=1789800012"},{"product_id":"siemens-6gk7443-1ex30-0xe0-cp-443-1-communication-module","title":"Siemens 6GK7443-1EX30-0XE0 SIMATIC S7-400 CP 443-1 PROFINET IO 2x RJ45 10\/100 Mbit\/s PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 443-1 (6GK7443-1EX30-0XE0) is a communication processor that links a SIMATIC S7-400 CPU to Industrial Ethernet via an integrated 2-port switch, offering 10\/100 Mbit\/s over two RJ45 ports with PROFINET IO controller support for up to 128 IO devices. It also handles S7 communication, open communication (SEND\/RECEIVE), S7 routing, and IP-based access control, drawing 5 V from the backplane bus at 1.4 A typical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7443-1EX30-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 443-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-400 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Ethernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5 V, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Controller - Max. IO Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Controller - Max. IRT Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal PROFINET IO Lines per Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max., multi-CPU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 128-device PROFINET IO controller capacity and 64 IRT-capable devices make this the CP to choose over the CP 343-1 when the station needs a larger, isochronous-capable IO network on an S7-400 backplane rather than S7-300. Four external PROFINET IO lines per rack allow splitting that device count across separate physical lines for cable-length or segmentation reasons, and the ACL and port-blocking security functions isolate the Ethernet segment without extra hardware.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnects S7-400 CPUs to Industrial Ethernet\/PROFINET networks in larger machine and process control systems that need S7 routing between subnets, open communication with third-party Ethernet devices, and centralized time synchronization via NTP or SICLOCK.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960703607067,"sku":"6GK7443-1EX30-0XE0","price":3512.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7443-1ex30-0xe0-cp-443-1-communication-module.png?v=1789681275"},{"product_id":"siemens-6gk7443-1gx30-0xe0-cp-443-1-advanced","title":"Siemens 6GK7443-1GX30-0XE0 SIMATIC NET CP 443-1 Advanced Gigabit PROFINET PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 443-1 Advanced (6GK7443-1GX30-0XE0) is a communications processor that connects a SIMATIC S7-400 CPU to Industrial Ethernet with one Gigabit RJ45 port and a 4-port 10\/100 Mbit\/s integrated switch, operating as a PROFINET IO controller for up to 128 IO devices with IRT support. It adds S7 routing, IP access control lists, and FTP\/email\/web server functions, drawing 1.8 A typical from the backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7443-1GX30-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 443-1 Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 (1x Gigabit + 4x switched 10\/100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interface 1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interface 2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5V typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, up to 128 IO devices (64 IRT-capable), 4 external PROFINET lines per rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (SEND\/RECEIVE, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 (with several CPUs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFTP Connections (client \/ server, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPSec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Encryption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAES-256, AES-192, AES-128, 3DES-168, DES-56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVPN Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirewall\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStateful inspection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-400 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Units per CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 (max. 4 as PN IO controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4-port switch plus a separate Gigabit uplink let this CP terminate a local PROFINET IO line on the integrated switch while carrying backbone traffic over the Gigabit port, and up to 4 units per S7-400 CPU can each run as an independent PROFINET IO controller for 128 devices. Select it over a Lean or non-Advanced CP 443 when the station needs Gigabit backbone speed, VPN\/firewall security, or multiple parallel PROFINET IO controller instances on the same rack.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits S7-400 stations that need a marine-classified PROFINET IO controller (ABS, BV, CCS, DNV, LRS, NK approvals) for process and marine automation, plus FTP, email, and web-based diagnostics for plant-wide integration.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960703639835,"sku":"6GK7443-1GX30-0XE0","price":3907.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7443-1gx30-0xe0-cp-443-1-advanced-communication-module.png?v=1789826100"},{"product_id":"siemens-6gk7443-5dx05-0xe0-cp-443-5-ext-communication-module","title":"Siemens 6GK7443-5DX05-0XE0 SIMATIC S7-400 CP 443-5 EXT PROFIBUS DP 12 Mbit\/s PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 443-5 Extended (6GK7443-5DX05-0XE0) is a communication processor that connects a SIMATIC S7-400 CPU to PROFIBUS DP, acting as a DP master (DPV1) for up to 125 distributed I\/O devices at transfer rates from 9.6 kbit\/s to 12 Mbit\/s over a 9-pin Sub-D RS485 port. It also supports S7 communication, open communication (SEND\/RECEIVE), and dataset routing, drawing 5 V from the backplane bus at 0.6 A typical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7443-5DX05-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 443-5 Extended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-400 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS485), PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master - Operable DP Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Range Inputs \/ Outputs (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 byte \/ 4096 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Range per DP Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244 byte (in) \/ 244 byte (out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 5 V, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 x 290 x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC for hazardous zone\u003c\/li\u003e\n\u003cli\u003eFM registration\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 125-device DP master capacity and 4096 byte total I\/O address range make this CP the choice when an S7-400 station needs PROFIBUS DP as a dedicated fieldbus alongside PROFINET handled by a separate CP 443-1 - up to 10 CP 443-5 Extended modules can operate as DP masters in one S7-400 station. Dataset routing with up to 30 connections lets engineering tools reach DP slaves through the S7-400 backplane without a direct PROFIBUS connection at the PC.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnects PROFIBUS DP field devices - drives, remote I\/O, valve islands - to an S7-400 CPU in process and machine control systems that still run PROFIBUS-based field instrumentation alongside newer PROFINET segments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960703705371,"sku":"6GK7443-5DX05-0XE0","price":2231.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7443-5dx05-0xe0-cp-443-5-ext-communication-module.png?v=1789681281"},{"product_id":"siemens-6gk7542-1ax00-0xe0-cm-1542-1-communication-module","title":"Siemens 6GK7542-1AX00-0XE0 SIMATIC S7-1500 CM 1542-1 PROFINET IO PLC Communication Module","description":"\u003cp\u003eThe Siemens CM 1542-1 (6GK7542-1AX00-0XE0) is a communications module that connects a SIMATIC S7-1500 CPU to PROFINET as an IO controller or IO device, supporting TCP\/IP, ISO-on-TCP, UDP, and S7 communication over two RJ45 ports at 10\/100 Mbit\/s. It adds IP broadcast\/multicast, SNMPv1, and NTP time synchronization, and weighs 0.36 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7542-1AX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM 1542-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169230100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x RJ45 port, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO Controller or IO Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, ISO-on-TCP, UDP, S7 communication, SNMPv1, NTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs a spare part, this CM covers baseline PROFINET connectivity for an S7-1500 station - TCP\/IP, ISO-on-TCP, and UDP open communication plus S7 communication as either an IO controller or IO device. Choose it when a station needs a second or replacement PROFINET port without the PROFIBUS DP interface the CM 1542-5 modules add.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdds a PROFINET interface to SIMATIC S7-1500 stations exchanging data with other S7 controllers, HMI, or SCADA systems over TCP\/IP or S7 communication.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960703738139,"sku":"6GK7542-1AX00-0XE0","price":1197.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7542-1ax00-0xe0-cm-1542-1-communication-module.png?v=1789826107"},{"product_id":"siemens-6gk7542-5dx00-0xe0-cm-1542-5-communication-module","title":"Siemens 6GK7542-5DX00-0XE0 SIMATIC S7-1500 CM 1542-5 PROFIBUS DP PLC Communication Module","description":"\u003cp\u003eThe Siemens CM 1542-5 (6GK7542-5DX00-0XE0) is a communications module that connects a SIMATIC S7-1500 CPU to PROFIBUS DP as a DP-V1 master or DP device, supporting S7 and PG\/OP communication, data record routing, and time synchronization across the PROFIBUS segment. It weighs 0.379 kg, is supplied as a Siemens spare part, and includes onboard diagnostics that flag PROFIBUS network faults directly through the S7-1500 CPU.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7542-5DX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM 1542-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169224260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDP-V1 master or DP device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7 communication, PG\/OP communication, data record routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard PROFIBUS diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.379 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis spare-part CM adds PROFIBUS DP master or device connectivity to an S7-1500 station, with data record routing letting the CPU pass PROFIBUS diagnostic and parameter data through to engineering tools without a direct cable connection. Pick it over the CM 1542-1 when the station needs to talk to legacy PROFIBUS DP field devices instead of PROFINET.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnects SIMATIC S7-1500 stations to PROFIBUS DP field devices - drives, remote I\/O, or sensors - as either the network master or a DP device reporting into a higher-level master.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960703770907,"sku":"6GK7542-5DX00-0XE0","price":1197.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7542-5dx00-0xe0-cm-1542-5-communication-module.png?v=1789826113"},{"product_id":"siemens-6gk7542-5fx00-0xe0-cp-1542-5-communication-processor","title":"Siemens 6GK7542-5FX00-0XE0 SIMATIC S7-1500 CP 1542-5 PROFIBUS DP PLC Communication Module","description":"\u003cp\u003eThe Siemens CP 1542-5 (6GK7542-5FX00-0XE0) is a communications processor that connects a SIMATIC S7-1500 CPU to PROFIBUS DP at 9.6 kbit\/s to 12 Mbit\/s, operating as a DPV1 master for up to 32 DP devices or as a DP device itself. It supports S7 and PG\/OP communication over a 9-pin Sub-D RS485 port, drawing 0.1 A typical from the backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7542-5FX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 1542-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D socket (RS485), PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Master Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPV1, up to 32 DP devices; 2048 byte input\/output address range (244 byte per device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDP Device Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDPV0\/DPV1; 240 byte input\/output address range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Protocol Mode Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 V (backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (backplane, 15V typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (vertical install)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...40 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-1500 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 142 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Units per CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (depending on CPU type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs a DPV1 master this CP handles up to 32 PROFIBUS DP devices with 2048 byte of input and output address space, while as a DP device it presents 240 byte each way to a higher-level master - covering both roles from one module. Choose the CP 1542-5 over the spare-part CM 1542-5 when a full published spec sheet and current TED data are needed for a new design rather than a like-for-like replacement.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnects SIMATIC S7-1500 stations to PROFIBUS DP networks - as master for drives, remote I\/O, and sensors, or as a device reporting into a plant-wide PROFIBUS master - in installations that still run PROFIBUS alongside newer PROFINET segments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960704262427,"sku":"6GK7542-5FX00-0XE0","price":756.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7542-5fx00-0xe0-cp-1542-5-communication-module.png?v=1789826120"},{"product_id":"siemens-6gk7542-6ux00-0xe0-cp-1542sp-1","title":"Siemens 6GK7542-6UX00-0XE0 SIMATIC NET CP 1542SP-1 ET 200SP PROFINET Communication Module","description":"\u003cp\u003eThe Siemens 6GK7542-6UX00-0XE0 is a SIMATIC NET CP 1542SP-1 communication processor that connects a SIMATIC ET 200SP station to Industrial Ethernet over an integrated 2-port switch at 10 to 100 Mbit\/s. It handles open IE communication over TCP\/IP, ISO-on-TCP, and UDP, PG\/OP traffic, S7 routing, and NTP time synchronization, and requires a separate bus adapter.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7542-6UX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP 1542SP-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVia ET 200SP bus adapter (RJ45, FC, SCRJ), integrated switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (19.2...28.8V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. S7 Communication Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Open Communication Connections (T-blocks)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. User Data per ISO-on-TCP Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65,536 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Multi-Protocol Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Modules per CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation (Vertical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to +50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 x 117 x 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUp to 2 CP 1542SP-1 modules can be plugged per ET 200SP CPU for redundant or segmented network connections, and simultaneous operation alongside a CM DP module is supported if PROFIBUS is also needed on the same station. The 32 open (T-block) connections plus 16 S7 connections give enough headroom for a station also running SNMP, DCP, and LLDP management traffic without exhausting connection resources. Because the bus adapter, RJ45, FC, or SCRJ, is ordered separately, confirm the physical media choice before ordering - the CP itself is media-agnostic at the module level.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdding a second, independently addressable Industrial Ethernet connection to a SIMATIC ET 200SP station for network segmentation, redundant PG\/OP access, open TCP\/IP or UDP communication to third-party devices, or NTP-synchronized time distribution.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960704295195,"sku":"6GK7542-6UX00-0XE0","price":621.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7542-6ux00-0xe0-cp-1542sp-1-communication-processor.png?v=1789679095"},{"product_id":"siemens-6gk7543-1ax10-0xe0-cp-1543-1-communication-processor","title":"Siemens 6GK7543-1AX10-0XE0 SIMATIC S7-1500 CP 1543-1 Gigabit Ethernet Security Communication Processor","description":"\u003cp\u003eThe Siemens 6GK7543-1AX10-0XE0 CP 1543-1 is a communication processor that gives a SIMATIC S7-1500 CPU an additional Industrial Ethernet interface, supporting 10\/100\/1000 Mbit\/s over one RJ45 port with TCP\/IP, ISO, UDP, and S7 communication. It includes a stateful-inspection firewall and IPsec VPN with up to 16 connections and AES-256 encryption for secure plant network segmentation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK7543-1AX10-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eCP 1543-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet interface\u003c\/td\u003e\n\u003ctd\u003e1x RJ45, 10-1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane supply\u003c\/td\u003e\n\u003ctd\u003e15 V DC, 0.25 A typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e3.75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (vertical)\u003c\/td\u003e\n\u003ctd\u003e-30...+40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (horizontal)\u003c\/td\u003e\n\u003ctd\u003e-30...+60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax installation altitude\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule format\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-1500, single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 142 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax units per CPU\u003c\/td\u003e\n\u003ctd\u003e8, depending on CPU type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen communication connections (max)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS7 communication connections (max)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTP connections (client \/ server)\u003c\/td\u003e\n\u003ctd\u003e32 \/ 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirewall type\u003c\/td\u003e\n\u003ctd\u003eStateful inspection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN connections\u003c\/td\u003e\n\u003ctd\u003e16, IPsec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN encryption\u003c\/td\u003e\n\u003ctd\u003eAES-256, AES-192, AES-128, 3DES-168, DES-56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN authentication\u003c\/td\u003e\n\u003ctd\u003ePreshared key (PSK), X.509v3 certificates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime synchronization\u003c\/td\u003e\n\u003ctd\u003eNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration software\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 Professional V19 (TIA Portal) or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUp to 8 units per CPU and 118 simultaneous open-communication or S7 connections make the CP 1543-1 suited to S7-1500 stations that need many parallel Ethernet links, well beyond what the CP 1243-1 supports on an S7-1200. It does not carry DNP3 or IEC 60870-5 telecontrol protocols, so it is the choice for standard plant TCP\/IP networking and VPN-secured segmentation rather than substation telecontrol reporting. Sixteen concurrent IPsec VPN connections with AES-256 support isolating an S7-1500 cell on its own encrypted segment while still allowing multiple remote engineering sessions.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdditional Gigabit Ethernet interface for S7-1500 CPUs, VPN-secured remote access and network segmentation, FTP and email-based IT integration, and static IP routing between plant network segments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960704327963,"sku":"6GK7543-1AX10-0XE0","price":1938.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7543-1ax10-0xe0-cp-1543-1-communication-processor.png?v=1789715060"},{"product_id":"siemens-6gk7543-1mx00-0xe0-tim-1531-irc-telecontrol-module","title":"Siemens 6GK7543-1MX00-0XE0 SIMATIC NET TIM 1531 IRC SINAUT DNP3 IEC 60870-5 Telecontrol Module","description":"\u003cp\u003eThe Siemens TIM 1531 IRC (6GK7543-1MX00-0XE0) is a telecontrol interface module for SIMATIC S7-1500, S7-400, S7-300, and ET200SP stations, supporting SINAUT ST7, DNP3, and IEC 60870-5-101\/104 protocols over three RJ45 ports and one switchable RS-232\/RS-485 interface. It buffers up to 250,000 events during a connection outage and synchronizes time from an NTP server or control center.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK7543-1MX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIM 1531 IRC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3x RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interface 1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Interfaces 2-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D, RS232 switchable to RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300...115200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Card Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x (SD 1.0, SD 1.1, SDHC, Siemens SMC), up to 32 GiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4...28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed Current (typical \/ maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 A \/ 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (update \/ communication mode, typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTelecontrol Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAUT ST7, DNP3, IEC 60870-5-101\/104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Buffering if Connection Aborted\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 telegrams (ST7) or 250,000 events (IEC 60870-5 \/ DNP3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Points per Device (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNP3 Masters (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (Ethernet), 4 (RS-232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS7 Communication Connections (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 (LAN only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length (RS-232 \/ RS-485, max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 m \/ 30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact module S7-1500 double-wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.525 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Units per S7-1500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe double-wide format and three Ethernet ports plus a switchable RS-232\/RS-485 interface let this TIM run parallel telecontrol paths - LAN\/WAN via Ethernet and a classic dial-up or radio link via the serial port - buffering up to 250,000 events if either connection drops. Its cross-platform compatibility with S7-1500, S7-400, S7-300, and ET200SP backplanes makes it the choice when a single telecontrol module design needs to cover mixed-CPU installations rather than a PROFINET or PROFIBUS-only CM or CP module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to substations, pumping stations, and remote SCADA-connected sites running SINAUT ST7, DNP3, or IEC 60870-5-101\/104 telecontrol protocols across mixed SIMATIC S7-1500, S7-400, S7-300, or ET200SP hardware.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960704426267,"sku":"6GK7543-1MX00-0XE0","price":2493.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7543-1mx00-0xe0-tim-1531-irc-telecontrol-module.png?v=1789826133"},{"product_id":"siemens-6gk7545-1gx00-0xe0-cp-1545-1-comms-processor","title":"Siemens 6GK7545-1GX00-0XE0 SIMATIC S7-1500 CP 1545-1 Industrial Ethernet Communications Processor","description":"\u003cp\u003eThe Siemens 6GK7545-1GX00-0XE0 CP 1545-1 is a communications processor that connects a SIMATIC S7-1500 CPU to Industrial Ethernet through a single RJ45 port running from 10 to 1000 Mbit\/s. It adds TCP\/IP, S7 communication, and MQTT cloud connectivity to the CPU, plus a stateful firewall with IPSec VPN for up to 16 secured connections, and up to eight modules can run per CPU depending on CPU type.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ MLFB\u003c\/td\u003e\n\u003ctd\u003e6GK7545-1GX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eCP 1545-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eCompact module, S7-1500 single width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e1x RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e10 ... 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, UDP, S7 communication, MQTT, SNMP v1\/v3, DHCP, FTP client\/server, email, NTP, IPv4\/IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Connectivity\u003c\/td\u003e\n\u003ctd\u003eMQTT, up to 500 data points per device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eStateful inspection firewall, IPSec VPN (AES-256\/AES-192\/AES-128\/3DES-168\/DES-56), up to 16 VPN connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS7 Communication Connections\u003c\/td\u003e\n\u003ctd\u003eup to 118, depending on system upper limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Communication (T-blocks)\u003c\/td\u003e\n\u003ctd\u003eup to 118 connections, 65536 byte max ISO-on-TCP user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Units per CPU\u003c\/td\u003e\n\u003ctd\u003eup to 8, depending on CPU type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e15 V DC from backplane bus, +-3% tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.3 A typical at 15 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 degC vertical installation, 0 ... 60 degC horizontal busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage \/ Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eup to 95% at 25 degC, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 142 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eS7-1500 rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 Professional V15.1 (TIA Portal) or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 16-connection IPSec VPN and stateful firewall make the CP 1545-1 the module to add when an S7-1500 station needs a protected remote-access or cloud path rather than plain Ethernet exposure through the CPU's integrated port. Its MQTT client and 500-data-point limit fit periodic telemetry to a cloud broker, not high-frequency process data acquisition. Because up to eight modules can share one CPU (the exact count depends on CPU type), a station that needs several isolated network segments - for example a plant network plus a separate maintenance VPN - can add a second or third CP 1545-1 instead of routing everything through one interface.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960704459035,"sku":"6GK7545-1GX00-0XE0","price":2079.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk7545-1gx00-0xe0-cp-1545-1-communications-processor.png?v=1789826139"}],"url":"https:\/\/stoklink.com\/collections\/plc-communication-modules.oembed?page=4","provider":"Stoklink","version":"1.0","type":"link"}