{"title":"PLC Power Supplies, Memory Cards \u0026 Accessories","description":"\u003cp\u003ePLC power supplies, memory cards and accessories from Siemens, Schneider Electric and ABB. The range has over 160 products, including 24 V DC power supply modules, mounting rails, sync cables, terminating connectors and battery boards for S7-400, S7-1500, S7-1200 and Modicon X80. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePLC power supply modules: PS405 for S7-400, PM 1207 for S7-1200 and Modicon X80 supplies.\u003c\/li\u003e\n\u003cli\u003eMounting rails and rack parts for S7-1500.\u003c\/li\u003e\n\u003cli\u003eSync cables for S7-1500H and terminating connectors for S7-400 interface modules.\u003c\/li\u003e\n\u003cli\u003eBattery boards and backup batteries for real-time clock retention.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutput current: total the draw of CPU and modules, then add margin.\u003c\/li\u003e\n\u003cli\u003eInput voltage: 24 V DC or 120\/230 V AC input must match the control cabinet supply.\u003c\/li\u003e\n\u003cli\u003ePlatform match: supplies and memory cards are series-specific.\u003c\/li\u003e\n\u003cli\u003eCable length: sync and interface cables come in fixed lengths, so measure the rack distance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I use any 24 V supply for a PLC?\u003c\/h3\u003e\n\u003cp\u003eOnly if it delivers stable, regulated 24 V DC at the needed current. Platform power modules also feed the backplane, which a generic supply cannot do.\u003c\/p\u003e\n\u003ch3\u003eWhat does a battery board do in an S7-1200?\u003c\/h3\u003e\n\u003cp\u003eIt keeps the real-time clock running when the CPU has no power, for a limited period.\u003c\/p\u003e\n\u003ch3\u003eDo you export small PLC accessories?\u003c\/h3\u003e\n\u003cp\u003eStoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"siemens-6es7901-0bf00-0aa0-s7-mpi-cable-5m","title":"Siemens 6ES7901-0BF00-0AA0 SIMATIC S7 MPI Cable 5m PLC Accessory","description":"\u003cp\u003eThe Siemens 6ES7901-0BF00-0AA0 is a SIMATIC S7 MPI cable, 5 m long, for connecting SIMATIC S7 controllers to a PG\/PC MD-57A programming device over the MPI port. It weighs 293 g and terminates in MPI-sized connectors on both ends, with no active electronics or signal converters built into the cable jacket itself.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7901-0BF00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169009577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eMPI cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e293 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959555318043,"sku":"6ES7901-0BF00-0AA0","price":43.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7901-0bf00-0aa0-s7-mpi-cable-5m-plc-accessory.png?v=1789798421"},{"product_id":"siemens-6es7972-0aa02-0xa0-rs485-repeater-profibus-mpi","title":"Siemens 6ES7972-0AA02-0XA0 SIMATIC DP RS485 Repeater PROFIBUS\/MPI 12Mbit\/s PLC Accessory","description":"\u003cp\u003eThe Siemens 6ES7972-0AA02-0XA0 is a SIMATIC DP RS485 repeater that extends PROFIBUS or MPI bus systems up to 31 nodes at transmission rates from 9.6 kbit\/s to 12 Mbit\/s. It runs on 24 V DC, draws up to 100 mA unloaded, and carries an IP20 enclosure rating with two terminal blocks for the PROFIBUS cable connections.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0AA02-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (20.4 ... 28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, max.\u003c\/td\u003e\n\u003ctd\u003e100 mA unloaded; up to 200 mA with 24V\/100mA load at PG\/OP socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, typ.\u003c\/td\u003e\n\u003ctd\u003e0.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS DP Transmission Rate, max.\u003c\/td\u003e\n\u003ctd\u003e12 Mbit\/s (9.6 kbit\/s to 12 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Nodes\u003c\/td\u003e\n\u003ctd\u003e31; PROFIBUS\/MPI bus systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, storage\/transport\u003c\/td\u003e\n\u003ctd\u003e-40 ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, operation, max.\u003c\/td\u003e\n\u003ctd\u003e95 % at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, Supply Voltage\u003c\/td\u003e\n\u003ctd\u003eTerminal module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, PROFIBUS Cables\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e45 x 128 x 59.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eA repeater is needed on PROFIBUS or MPI segments once a run exceeds the standard RS485 cable length or node limits for the configured baud rate, or when a segment needs galvanic isolation between two bus sections; this unit supports up to 31 nodes per extended segment. Because the transmission rate spans the full 9.6 kbit\/s to 12 Mbit\/s PROFIBUS DP range, it works with both slow MPI segments and high-speed 12 Mbit\/s DP segments without manual rate configuration. IP20 rating and 24 V DC supply keep it in the same enclosure class as standard control-cabinet components.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eExtends PROFIBUS DP or MPI networks in control cabinets or across machine sections where cable length, node count, or electrical isolation between segments exceeds what a single unbroken bus run supports.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959581204763,"sku":"6ES7972-0AA02-0XA0","price":571.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7972-0aa02-0xa0-rs485-repeater-profibus-mpi.png?v=1789680098"},{"product_id":"siemens-6es7972-0ba61-0xa0-profibus-connector","title":"Siemens 6ES7972-0BA61-0XA0 SIMATIC DP PROFIBUS Bus Connector 35° FastConnect PLC Accessory","description":"\u003cp\u003eThe Siemens 6ES7972-0BA61-0XA0 is a PROFIBUS bus connector for RS 485 networks with a 35-degree cable outlet, supporting transfer rates from 9.6 kbit\/s up to 12 Mbit\/s. FastConnect insulation-displacement terminals accept two-core PROFIBUS FC cable, and the connector carries an integrated, switch-selectable terminating resistor in an IP20 plastic enclosure rated for -25 to +60C, suited to panel and field DP station connections.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0BA61-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623406877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s (PROFIBUS DP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Cable Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Equipment Connection\u003c\/td\u003e\n\u003ctd\u003e9-pin sub-D connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Termination Method\u003c\/td\u003e\n\u003ctd\u003eIntegrated insulation displacement terminals, FastConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminating Resistor\u003c\/td\u003e\n\u003ctd\u003eIntegrated, switch-selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Outlet Angle\u003c\/td\u003e\n\u003ctd\u003e35 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e15.8 x 54 x 39.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e29 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe FastConnect insulation-displacement termination cuts wiring time versus screw-terminal PROFIBUS connectors — strip, seat, and close, with no separate crimp tool. The 35-degree cable outlet reduces bend-radius stress in tight panel and junction-box layouts compared with a straight exit. The built-in switchable terminating resistor lets this connector serve as a bus-end node without a separate terminator, provided it sits at the physical end of the segment.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed to terminate PROFIBUS DP stations onto the bus cable in panel-mounted drives, remote I\/O stations, and field devices where FastConnect wiring and a compact 35-degree exit are needed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959581958427,"sku":"6ES7972-0BA61-0XA0","price":56.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7972-0ba61-0xa0-profibus-connector-plc-accessory.png?v=1789663917"},{"product_id":"siemens-6es7972-0bb61-0xa0-profibus-bus-connector","title":"Siemens 6ES7972-0BB61-0XA0 PROFIBUS Bus Connector 35 Degree FastConnect PLC Accessory","description":"\u003cp\u003eThe Siemens 6ES7972-0BB61-0XA0 is a PROFIBUS bus connector with FastConnect insulation-displacement terminals and a 35 degree cable outlet, used to connect PROFIBUS DP stations to the bus cable at transfer rates from 9.6 kbit\/s up to 12 Mbit\/s. It terminates two PROFIBUS cables via IDC contacts and provides a 9-pin Sub-D port with an integrated programming socket.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0BB61-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS bus connector, RS 485, FastConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (PROFIBUS DP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s ... 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFIBUS Cable Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, integrated IDC FastConnect terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork\/Terminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminating Resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated, slide-switch selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.8 x 54 x 39.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 35 degree cable outlet keeps the connector profile low against the PROFIBUS station housing, which matters in cabinets with tight DIN-rail spacing compared to straight or 90 degree outlet variants in the same connector family. FastConnect insulation-displacement termination avoids stripping and crimping individual conductors, cutting assembly time on multi-drop PROFIBUS DP segments.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTerminates SIMATIC S7-300\/S7-400 and distributed I\/O PROFIBUS DP stations onto the bus cable, with the integrated programming port letting a PG\/PC tap into the segment without breaking the bus connection.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959586349339,"sku":"6ES7972-0BB61-0XA0","price":74.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7972-0bb61-0xa0-profibus-bus-connector.png?v=1789680685"},{"product_id":"siemens-6es7972-0da00-0aa0-rs485-terminating-resistor","title":"Siemens 6ES7972-0DA00-0AA0 SIMATIC DP RS485 Terminating Resistor PROFIBUS MPI PLC Accessory","description":"\u003cp\u003eThe Siemens 6ES7972-0DA00-0AA0 is a SIMATIC DP RS485 terminating resistor for closing PROFIBUS or MPI network segments, powered from a 24 VDC bus supply within a 20.4-28.8 V range and drawing 30 mA typical. It supports transmission rates up to 12 Mbit\/s, carries an IP20 enclosure rated for 0 to 60 degrees C operation, and weighs 95 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0DA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515063001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eRS485 Terminating Resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage, Rated (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range (DC)\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, typ.\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, max.\u003c\/td\u003e\n\u003ctd\u003e0.72 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage\/Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Operation, max.)\u003c\/td\u003e\n\u003ctd\u003e95 percent at +25 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection (Supply Voltage)\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection (PROFIBUS Cables)\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaritime Approval\u003c\/td\u003e\n\u003ctd\u003eKR (Korean Register of Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis terminating resistor closes the RS485 bus electrically at the physical end of a PROFIBUS or MPI segment; installing one only at each of the two segment ends, not on every station, keeps reflections and signal levels within spec at the full 12 Mbit\/s rate. Match its 24 VDC bus-supply need against the segment design when using unpowered stations, since active bus termination on PROFIBUS\/MPI needs its own 24 V feed unlike a passive terminator.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eInstalled at the electrical ends of a PROFIBUS DP or MPI RS485 segment to prevent signal reflections on multidrop networks connecting SIMATIC controllers, HMIs, and field devices.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959586382107,"sku":"6ES7972-0DA00-0AA0","price":136.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7972-0da00-0aa0-rs485-terminating-resistor.png?v=1789799720"},{"product_id":"siemens-6au1400-2qa20-0aa0-simotion-d-2gb-cf-card","title":"Siemens 6AU1400-2QA20-0AA0 SIMOTION D 2GB CF Card for D4x5-2 Memory Card","description":"\u003cp\u003eThe Siemens 6AU1400-2QA20-0AA0 is a 2 GB Compact Flash card for SIMOTION D4x5-2 drive-based controllers, preloaded with the SINAMICS drive software V5.x and the matching SIMOTION kernel at the current software version. It is not compatible with the SIMOTION D410, D4x5, or D410-2 controller variants, so the exact controller generation must be confirmed before ordering it as a spare or replacement part.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6AU1400-2QA20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMOTION D410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003eSIMOTION D CF Card 2 GB for D4x5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible controllers\u003c\/td\u003e\n\u003ctd\u003eSIMOTION D4x5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot compatible with\u003c\/td\u003e\n\u003ctd\u003eSIMOTION D410, D4x5, D410-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreloaded software\u003c\/td\u003e\n\u003ctd\u003eSINAMICS drive software V5.x, SIMOTION kernel for D4x5-2 (current version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe D4x5-2 compatibility note is the detail that matters when ordering: this 2 GB card is built for the second-generation D4x5-2 controllers and is explicitly ruled out for the original D410, D4x5, and D410-2 models, so confirm the controller generation before ordering a replacement or spare card. Siemens lists it as compatible alongside the smaller-capacity 1 GB CF card 6AU1400-2PA23-0AA0 for the same controller family, so capacity choice comes down to project size and firmware\/data storage headroom rather than compatibility.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960403714331,"sku":"6AU1400-2QA20-0AA0","price":313.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6au1400-2qa20-0aa0-simotion-d-2gb-cf-card-plc-memory-card.png?v=1789679365"},{"product_id":"siemens-6au1400-3sa20-0aa0","title":"Siemens 6AU1400-3SA20-0AA0 SIMOTION D4x5-2 8 GB SD Memory Card","description":"\u003cp\u003eThe Siemens 6AU1400-3SA20-0AA0 is an 8 GB SD memory card for the SIMOTION D4x5-2 drive-based motion controller, preloaded with SINAMICS drive runtime software V5.x and the SIMOTION Kernel. It is intended specifically for the SIMOTION D435-2 and D455-2 control units (order numbers 6AU1435-2AD00-0AA2 and 6AU1455-2AD00-0AA2) and carries the current software version at time of shipment. Net weight is 0.03 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6AU1400-3SA20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMOTION\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC Memory Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Control Units\u003c\/td\u003e\n\u003ctd\u003eSIMOTION D435-2 (6AU1435-2AD00-0AA2), SIMOTION D455-2 (6AU1455-2AD00-0AA2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e8 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Type\u003c\/td\u003e\n\u003ctd\u003eSecure Digital (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreloaded Software\u003c\/td\u003e\n\u003ctd\u003eSINAMICS drive runtime software V5.x, SIMOTION Kernel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis memory card is specific to the -0AA2 variants of the SIMOTION D435-2 and D455-2 control units; it is not the general-purpose card for other D4x5-2 hardware revisions. Order this part number when replacing or provisioning the SD card for those two control units specifically, since it ships preloaded with the matching kernel and drive runtime version.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960403943707,"sku":"6AU1400-3SA20-0AA0","price":16.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-product-image-coming-soon_05704140-e6aa-4b58-b04c-274969cd92ad.png?v=1789640009"},{"product_id":"siemens-6ep1332-4ba00-pm1507-s7-1500-power-supply","title":"Siemens 6EP1332-4BA00 PM 1507 S7-1500 Power Module 24 V DC\/3 A PLC Power Supply","description":"\u003cp\u003eThe Siemens 6EP1332-4BA00 is the PM 1507 power module for the SIMATIC S7-1500 system, delivering a stabilized 24 V DC \/ 3 A output from a single-phase 120\/230 V AC input with automatic range selection. At 87% efficiency and 72 W active power output, it dissipates only 11 W at full load. Galvanic isolation provides SELV \/ ES1 output classification per IEC 62368-1.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No. (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1332-4BA00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515152705\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 1507\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 Power Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Current Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V \/ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Network Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-phase AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V (85–132 V) \/ 230 V (170–264 V), automatic range selection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage at 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage at 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (45–65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 120 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 230 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (max, 25 °C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 A for 3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI²t Value (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 A²·s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Overload Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 × Vin rated, 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Buffering Time (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms at Vin = 93\/187 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT 3.15 A \/ 250 V (not accessible)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Feeder MCB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A characteristic B or 6 A characteristic C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A (range: 0–3 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Power Output (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Full Load (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Ripple (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Peak (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoft Start \/ Output Overshoot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo overshoot (soft start)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Increase Time (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Delay (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A for 70 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limitation Response Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15–3.6 A (typical 3.4 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic shutdown, automatic restart\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdditional control loop, limitation at \u0026lt; 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2 units for increased power\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Current (max \/ typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 mA \/ 0.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Precision — Input Voltage Fluctuation (slow)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Precision — Input Voltage Fluctuation (rapid ±15%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Precision — Load Step 50\/100\/50 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Precision — Load Step 10\/90\/10 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSettling Time (load step, max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED green (24 V OK), LED red (error), LED yellow (standby)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal, 1 × L, N, PE; 0.5–2.5 mm² (removable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded terminals, 2 × L+, M; 0.5–2.5 mm² (removable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–60 °C (horizontal, natural convection); 0–40 °C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage \/ Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60721 Climate class 3K3, 5–95% RH, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC — Emitted Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC — Mains Harmonics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-3-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC — Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 611 993 h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 DIN rail; butt-mountable (0 mm lateral clearance)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Spacing — Top \/ Bottom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mm \/ 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 × 147 × 129 mm (installation height: 205 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRO (Romania)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85044083\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUKCA\u003c\/li\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eRCM\u003c\/li\u003e\n  \u003cli\u003eCB\u003c\/li\u003e\n  \u003cli\u003eUL 508\u003c\/li\u003e\n  \u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n  \u003cli\u003eBIS\u003c\/li\u003e\n  \u003cli\u003eIEC 62368-1\u003c\/li\u003e\n  \u003cli\u003eIEC 61204-7\u003c\/li\u003e\n  \u003cli\u003eEN 55022 Class B\u003c\/li\u003e\n  \u003cli\u003eEN 61000-3-2\u003c\/li\u003e\n  \u003cli\u003eEN 61000-6-2\u003c\/li\u003e\n  \u003cli\u003eABS\u003c\/li\u003e\n  \u003cli\u003eBV\u003c\/li\u003e\n  \u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe 6EP1332-4BA00 supplies 3 A at 24 V DC — sufficient for a compact S7-1500 station with a CPU plus a handful of I\/O modules drawing up to 72 W combined. Its 20 ms mains buffering at Vin = 93\/187 V covers brief supply dips without triggering a CPU restart. Where the station load exceeds 3 A, two PM 1507 units can be paralleled without additional hardware. Vertical mounting is permissible but derate the ambient limit to 40 °C; horizontal mounting retains the full 0–60 °C range. Choose the higher-rated PM 1507 5 A variant (6EP1333-4BA00) when module count or powered field devices push the 24 V bus above 72 W.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960451555611,"sku":"6EP1332-4BA00","price":158.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1332-4ba00-pm1507-s7-1500-power-supply.png?v=1789641222"},{"product_id":"siemens-6ep1333-4ba00-pm-1507-power-supply","title":"Siemens 6EP1333-4BA00 SIMATIC PM 1507 24V\/8A S7-1500 Power Supply","description":"\u003cp\u003eThe Siemens SIMATIC PM 1507 (6EP1333-4BA00) is a stabilized power module purpose-built for the S7-1500 rail, converting 120\/230 V AC input to a regulated 24 V DC \/ 8 A output. It reaches 90% efficiency, tolerates a 62 A inrush current, and carries CE, UKCA, and EAC approvals in an IP20 enclosure without Ex approval.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU (Order No.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1333-4BA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515152712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 1507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage, AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/230 V, automatic range (85-264 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (45-65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput power, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual ripple, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush current, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffering time at power failure, min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;28.8 V (closed-loop limitation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (input\/output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,362,918 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eshipbuilding\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 8 A \/ 192 W this is the higher-current step in the S7-1500 power module lineup, sized for racks with several I\/O modules or when the CPU's backplane load leaves little margin on a smaller supply. The 120\/230 V automatic range-selection input removes the manual voltage-tap step some earlier power supply generations required. Two units can be paralleled per the datasheet where a single PM 1507 does not cover the rack's total current draw. Vertical mounting derates the operating temperature range to 0-40°C versus 0-60°C horizontal, which is worth checking against the cabinet's planned orientation before specifying enclosure cooling.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e24 V DC bus supply for SIMATIC S7-1500 racks with multiple I\/O, communication, or technology modules where the CPU's backplane current draw exceeds what a smaller PM module or the CPU's integrated supply can deliver.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960451981595,"sku":"6EP1333-4BA00","price":221.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1333-4ba00-pm-1507-power-supply.png?v=1789681002"},{"product_id":"siemens-6es7133-6cv15-1am0-et200sp-bu-cover-15mm","title":"Siemens 6ES7133-6CV15-1AM0 SIMATIC ET 200SP BU Cover 15mm 5-Pack Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7133-6CV15-1AM0 is a pack of five SIMATIC ET 200SP BU covers, 15 mm wide, used to seal empty base-unit slots on an ET 200SP station. Each cover measures 73 mm high by 35.3 mm deep, rated for -40 to +70°C operation, and keeps enclosure protection intact where no I\/O module is installed yet.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7133-6CV15-1AM0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 covers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40…+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. installation altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.047 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSealing unused base-unit slots on partially populated ET 200SP stations to keep the assembled station's ingress protection intact until an I\/O module is added. Because the ET 200SP base rack accepts modules and covers in any slot order, this cover lets a panel builder commission a station in stages — installing I\/O modules as they become available and leaving remaining slots protected rather than exposed. Each cover snaps directly onto the base unit without tools, matching the 15 mm module pitch used across the ET 200SP I\/O range, and rated for the same -40 to +70°C operating range as the surrounding station.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960474755355,"sku":"6ES7133-6CV15-1AM0","price":27.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7133-6cv15-1am0-et200sp-bu-cover-15mm.png?v=1789681105"},{"product_id":"siemens-6es7133-6cv20-1am0-et200sp-bu-cover-20mm","title":"Siemens 6ES7133-6CV20-1AM0 SIMATIC ET 200SP BU Cover 20mm Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7133-6CV20-1AM0 is a 20 mm BU cover for the SIMATIC ET 200SP system, used to close off empty BaseUnit slots on the mounting rail. It measures 20 x 73 x 35.3 mm and operates from -40 to 70 degrees C, matching the temperature range of the active I\/O modules it sits beside.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7133-6CV20-1AM0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.059 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 C to 70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960475279643,"sku":"6ES7133-6CV20-1AM0","price":27.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7133-6cv20-1am0-et200sp-bu-cover-remote-io-accessory.png?v=1789780663"},{"product_id":"siemens-6es7138-7aa00-0aa0-et200isp-reserve-module","title":"Siemens 6ES7138-7AA00-0AA0 ET200iSP Reserve Module Ex ib IIC T4 Gb I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7138-7AA00-0AA0 is a reserve module for the SIMATIC ET200iSP intrinsically safe remote I\/O station, ATEX-approved for hazardous areas per marking II 2 G Ex ib IIC T4 Gb I M2 Ex ib I Mb. It occupies an unused station slot, connects to the station's DC supply, and has no active inputs or outputs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7138-7AA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eReserve module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage type\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of digital inputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G Ex ib IIC T4 Gb I M2 Ex ib I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 1251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e30 mm x 129 mm x 136.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e180 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is a passive reserve module, not an active I\/O channel: it fills an unused slot on an ET200iSP intrinsically safe station so the station's slot count and addressing stay fixed for later expansion with a live I\/O module. The Ex ib IIC T4 Gb I M2 Ex ib I Mb marking and KEMA 04 ATEX 1251 certificate mean it is rated for the same hazardous-area installation as the rest of the ET200iSP station, so it can be used in the intrinsically safe zone without a separate non-Ex approval check.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eReserves a slot in an ET200iSP intrinsically safe I\/O station for future channel expansion, keeping the station's module layout and addressing unchanged until an active I\/O module is installed in its place.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960506310939,"sku":"6ES7138-7AA00-0AA0","price":115.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7138-7aa00-0aa0-et200isp-reserve-module.png?v=1789681118"},{"product_id":"siemens-6es7138-7bb00-0ab0-et200isp-watchdog-module","title":"Siemens 6ES7138-7BB00-0AB0 SIMATIC ET 200iSP Watchdog Module Ex ib IIC T4 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7138-7BB00-0AB0 is a watchdog module for the SIMATIC ET 200iSP intrinsically safe I\/O station, monitoring the connected digital output modules on the power bus and reporting a group fault through its red SF LED. It runs from a 20.4-28.8 V DC supply, mounts on rail, front, or wall, and is rated IP30 with Ex ib IIC T4 Gb \/ Ex ib I Mb approval for Zone 1 gas and Group I mining areas.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7138-7BB00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169149105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eWatchdog module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware version\u003c\/td\u003e\n\u003ctd\u003eV1.0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront, rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage type\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e50 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic information readable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation\u003c\/td\u003e\n\u003ctd\u003eBetween channels and backplane bus; between channels and powerbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible potential difference\u003c\/td\u003e\n\u003ctd\u003e60 V DC \/ 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEx(i) max values, gas group IIC\u003c\/td\u003e\n\u003ctd\u003eUo 12.7 V, Io 329 mA, Po 0.91 W, Co 1 uF, Lo 0.3 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G Ex ib IIC T4 Gb; I M2 Ex ib I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 06 ATEX 0086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 06.0026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex\u003c\/td\u003e\n\u003ctd\u003e2020322316002993\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAC Ex\u003c\/td\u003e\n\u003ctd\u003e1Ex ib IIC T4 Gb; PB Ex ib I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM marking\u003c\/td\u003e\n\u003ctd\u003eClass I Zone 1 AEx ib IIC T4; Class I Division 2 GP A,B,C,D T4; DIP Class II, III GP E,F,G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e30 x 129 x 136.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e253 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis module has no digital inputs or fieldbus interfaces of its own; its job is watchdog supervision of the ET 200iSP power bus, so it is needed only when the station includes digital output modules whose power-bus feed must be monitored for a stuck or failed watchdog cycle. Its Ex ib IIC T4 Gb \/ Ex ib I Mb rating covers both surface gas Zone 1 installations and underground Group I mining areas from the same catalog number. The four marine class approvals (GL, ABS, BV, DNV) make it usable on shipboard hazardous-area I\/O stations without a separate maritime-rated variant.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960506802459,"sku":"6ES7138-7BB00-0AB0","price":245.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7138-7bb00-0ab0-et200isp-watchdog-module.png?v=1789780972"},{"product_id":"siemens-6es7148-4ca00-0aa0-pm-e-24v-dc-power-module","title":"Siemens 6ES7148-4CA00-0AA0 SIMATIC ET 200pro PM-E 24V DC 10A Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7148-4CA00-0AA0 is a 24 V DC power module for the SIMATIC ET 200pro distributed I\/O system, feeding load voltage to the electronic modules mounted on the same backplane segment. It carries up to 10 A on the internal busbars at ambient temperatures up to 55 degrees C and protects the circuit with an exchangeable fuse plus reverse-polarity protection against destruction.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7148-4CA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated load voltage 2L+\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eYes, via exchangeable fuse in the power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes, against destruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current from load voltage 2L+, max.\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, max.\u003c\/td\u003e\n\u003ctd\u003e10 A, up to 55 degrees C on internal busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, typ.\u003c\/td\u003e\n\u003ctd\u003e0.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic information readable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMissing load voltage diagnosis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation, load voltage \/ backplane bus\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e140 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eWith a 10 A busbar rating up to 55 degrees C, this module covers the higher-current end of ET 200pro I\/O groups on a single power segment; specify it where several electronic modules share one PM-E feed rather than splitting the station into extra potential groups. The exchangeable fuse means a short circuit on the load side is cleared without replacing the whole power module. It mounts to the ET 200pro backplane through a connection module that is ordered separately.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eET 200pro is a modular, machine-mounted distributed I\/O system, so this power module typically sits mid-station wherever a new load-voltage group starts on the backplane. The group error LED and missing-load-voltage diagnosis are reported back to the controller with the rest of the station's diagnostics, so a blown fuse or disconnected supply on this segment shows up without a separate wiring check.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960533934363,"sku":"6ES7148-4CA00-0AA0","price":76.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7148-4ca00-0aa0-pm-e-24v-dc-power-module.png?v=1789781225"},{"product_id":"siemens-6es7193-6af00-0aa0-et200sp-busadapter-ba-2xfc","title":"Siemens 6ES7193-6AF00-0AA0 SIMATIC ET 200SP BusAdapter BA 2xFC PROFINET Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AF00-0AA0 is a SIMATIC ET 200SP BusAdapter, type BA 2xFC, that fits the interface module's bus slot to add two FastConnect PROFINET ports for daisy-chaining ET 200SP stations. Each port supports up to 100 m of copper cabling, and the adapter carries an environmental product declaration with a total lifecycle CO2 footprint of 1.14 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AF00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA 2x FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2-port switch, 2x FastConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastConnect Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Cu conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential, total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.14 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA 2xFC BusAdapter mounts onto the ET 200SP interface module's bus slot to expose two FastConnect PROFINET ports, letting the station sit in a line topology without an external switch. Each port supports up to 100 m of copper cabling, matching standard Industrial Ethernet segment lengths. Choose it over a single-port BusAdapter when the station needs to daisy-chain to a downstream station rather than terminate the line.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLine-topology PROFINET wiring for SIMATIC ET 200SP distributed I\/O stations - connecting an interface module to both an upstream and downstream station without a separate switch.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960539570459,"sku":"6ES7193-6AF00-0AA0","price":90.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6af00-0aa0-et200sp-busadapter-ba-2xfc.png?v=1789715030"},{"product_id":"siemens-6es7193-6ag00-0aa0-ba-2xlc-busadapter","title":"Siemens 6ES7193-6AG00-0AA0 ET 200SP BusAdapter BA 2xLC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AG00-0AA0 is a SIMATIC ET 200SP BusAdapter (BA 2xLC) that replaces the copper PROFINET port of an ET 200SP interface module with two LC glass fiber-optic ports, covering up to 3 km on 50\/125 µm or 62.5\/125 µm multimode fiber. It mounts directly on the interface module's BusAdapter slot at just 20 mm width.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AG00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA 2x LC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; 2 ports (switch), LC multimode glass fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2; wavelength 1,270-1,380 nm, corresponds to 100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, 50\/125 µm Multimode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 km; min. transmit power -23.5 dB, min. receiver sensitivity -31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, 62.5\/125 µm Multimode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 km; min. transmit power -20 dB, min. receiver sensitivity -31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623406754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA 2xLC swaps the ET 200SP interface module's onboard copper PROFINET port for two LC glass fiber ports, the choice when a segment must cover up to 3 km - well beyond copper's practical reach - or route through electrically noisy plant areas immune to ground-loop interference on copper Ethernet. Glass fiber, unlike the shorter-range plastic\/PCF BusAdapters in the same family, is the pick when the run genuinely needs kilometer-class distance rather than a single machine-to-panel hop. At 20 mm width and 40 g it adds no extra footprint beyond the interface module it plugs into.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLong-distance PROFINET fiber links between ET 200SP stations spread across a plant, and segments routed through high-EMI zones where copper Ethernet risks ground-loop interference.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960539767067,"sku":"6ES7193-6AG00-0AA0","price":350.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ag00-0aa0-ba-2xlc-busadapter.png?v=1789781296"},{"product_id":"siemens-6es7193-6ag40-0aa0-ba-lc-fc-busadapter","title":"Siemens 6ES7193-6AG40-0AA0 ET 200SP BusAdapter BA LC\/FC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AG40-0AA0 is a SIMATIC ET 200SP BusAdapter (BA LC\/FC) that converts an ET 200SP interface module's PROFINET port to one LC glass fiber-optic port, up to 3 km, and one FastConnect copper port, up to 100 m, replacing the standard 2-port copper connection. It mounts directly on the interface module's BusAdapter slot at 20 mm width.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AG40-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA LC\/FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; 2 ports (switch) LC \/ FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of FC (FastConnect) Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; wavelength 1,270-1,380 nm, corresponds to 100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Cu Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, 50\/125 µm Multimode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 km; min. transmit power -23.5 dB, min. receiver sensitivity -31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, 62.5\/125 µm Multimode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 km; min. transmit power -20 dB, min. receiver sensitivity -31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623406761\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA LC\/FC mixes one glass fiber port with one copper FastConnect port on the same BusAdapter, the choice at a station that needs to continue a fiber backbone on one side while dropping a short copper run to the next panel on the other - a single-fiber BA 2xLC does not offer that copper leg. The glass fiber leg reaches up to 3 km, well past the 100 m copper leg, so segment planning should route the longer run over the LC port. Like the other BusAdapters in this family it adds no footprint beyond the interface module it plugs into.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMedia conversion point on an ET 200SP PROFINET line where one hop needs a fiber run into a remote panel and the other continues on standard copper cabling within the same station segment.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960539996443,"sku":"6ES7193-6AG40-0AA0","price":282.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ag40-0aa0-ba-lc-fc-busadapter.png?v=1789781303"},{"product_id":"siemens-6es7193-6ap00-0aa0-ba-2xscrj-busadapter","title":"Siemens 6ES7193-6AP00-0AA0 SIMATIC ET 200SP BusAdapter BA 2xSCRJ Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AP00-0AA0 is a SIMATIC ET 200SP BusAdapter (BA 2xSCRJ) that replaces the copper PROFINET port of an ET 200SP interface module with two SCRJ fiber-optic ports, supporting PCF fiber runs up to 100 m or plastic POF up to 50 m. It mounts directly on the interface module's BusAdapter slot at just 20 mm width.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AP00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA 2x SCRJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; 2 ports (switch), 2x SCRJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCRJ Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, PCF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Plastic FOC (POF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623403524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA 2xSCRJ swaps the ET 200SP interface module's onboard copper PROFINET port for two SCRJ fiber ports, which is the choice when a station segment runs through electrically noisy areas (near VFDs or welding equipment) or exceeds practical copper distances. PCF fiber covers 100 m and plastic POF covers 50 m, both suited to a single machine-to-panel hop rather than a plant-wide backbone. At 20 mm width and 50 g it adds no extra footprint beyond the interface module it plugs into, so it does not change the station's DIN-rail length.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eET 200SP stations wired through high-EMI zones where a fiber PROFINET hop avoids ground-loop interference on copper Ethernet, and panel-to-panel fiber links where cable trays cross high-voltage switchgear.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540193051,"sku":"6ES7193-6AP00-0AA0","price":350.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ap00-0aa0-ba-2xscrj-busadapter.png?v=1789679433"},{"product_id":"siemens-6es7193-6ap20-0aa0-ba-scrj-rj45-busadapter","title":"Siemens 6ES7193-6AP20-0AA0 SIMATIC ET 200SP BA SCRJ\/RJ45 BusAdapter Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AP20-0AA0 is a SIMATIC ET 200SP BusAdapter (BA SCRJ\/RJ45) that converts a PROFINET fiber-optic segment to copper, combining one SCRJ fiber port with one RJ45 copper port on the same interface module. It extends fiber-optic cable runs up to 100 m on PCF and up to 50 m on plastic FOC, with a single copper RJ45 uplink to the rest of the network.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AP20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623405610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA SCRJ\/RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (2 ports: 1x SCRJ, 1x RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length (PCF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length (Plastic FOC\/POF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length (Cu conductors)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Horizontal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Vertical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose this SCRJ\/RJ45 BusAdapter over the all-copper BA 2x RJ45 variant when one port of the ET 200SP station needs to run over a plastic or PCF fiber-optic link — for EMI-heavy environments or cable runs where copper's distance limit is a problem — while the other port stays on standard RJ45 copper for the rest of the network. There are no configurable parameters on the BusAdapter itself — module diagnostics and network settings are handled entirely by the ET 200SP interface module it plugs into.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMixed fiber\/copper PROFINET wiring on ET 200SP stations where part of the network run needs fiber-optic isolation or extended distance and the rest stays on standard Ethernet cabling.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540258587,"sku":"6ES7193-6AP20-0AA0","price":269.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ap20-0aa0-ba-scrj-rj45-busadapter.png?v=1789680556"},{"product_id":"siemens-6es7193-6ap40-0aa0-ba-scrj-fc-busadapter","title":"Siemens 6ES7193-6AP40-0AA0 ET 200SP BusAdapter BA SCRJ\/FC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AP40-0AA0 is a SIMATIC ET 200SP BusAdapter (BA SCRJ\/FC) that converts an ET 200SP interface module's PROFINET port to one SCRJ fiber-optic port and one FastConnect copper port, supporting PCF fiber up to 100 m, plastic POF up to 50 m, or copper up to 100 m. It mounts directly on the interface module's BusAdapter slot at 20 mm width.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AP40-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA SCRJ\/FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; 2 ports (switch) SCRJ\/FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of FC (FastConnect) Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of SCRJ Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, PCF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Plastic FOC (POF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Cu Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623405627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA SCRJ\/FC pairs one polymer\/PCF fiber port with one FastConnect copper port, aimed at short-hop fiber runs - 100 m on PCF, 50 m on plastic POF - rather than the multi-kilometer reach of the glass-fiber BA LC\/FC or BA 2xLC variants; pick it when the fiber leg only needs to cross a machine cell or clear a few meters of EMI-heavy cabling, not a plant-wide backbone. The copper FastConnect leg on the other port covers a conventional 100 m run to the next panel.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eShort-range fiber-to-copper media conversion on an ET 200SP PROFINET line within a single machine cell or across localized EMI sources, where full glass-fiber distance is not needed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540324123,"sku":"6ES7193-6AP40-0AA0","price":282.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ap40-0aa0-ba-scrj-fc-busadapter.png?v=1789781309"},{"product_id":"siemens-6es7193-6ar00-0aa0-busadapter-ba-2xrj45","title":"Siemens 6ES7193-6AR00-0AA0 SIMATIC ET 200SP BusAdapter BA 2xRJ45 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AR00-0AA0 is a SIMATIC ET 200SP BusAdapter BA 2xRJ45, an integrated 2-port PROFINET switch adapter with 2 RJ45 sockets that connects an ET 200SP interface module into a line or star PROFINET topology over copper cable runs up to 100 m.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AR00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AR00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA 2x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (2-port integrated switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length, Cu conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BA 2xRJ45 is the copper, 2-port variant of the ET 200SP BusAdapter line: both ports are on the same switch, so it slots into a PROFINET line topology or feeds a second station downstream, rather than terminating the network. Cable runs up to 100 m per segment on standard Cu cabling match typical Cat5e\/Cat6 PROFINET wiring without needing fiber.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnects an ET 200SP interface module to a PROFINET line or star network over copper RJ45 cabling, and links additional ET 200SP stations further down the same line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540520731,"sku":"6ES7193-6AR00-0AA0","price":73.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ar00-0aa0-busadapter-ba-2xrj45.png?v=1789662589"},{"product_id":"siemens-6es7193-6as00-0aa0-ba-send-busadapter","title":"Siemens 6ES7193-6AS00-0AA0 ET 200SP BusAdapter BA-Send 1xFC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6AS00-0AA0 is a SIMATIC ET 200SP BusAdapter (BA-Send 1xFC) that starts the sending side of an ET-Connection link, extending a station over Cu FastConnect cable via a single FastConnect termination. It mounts on the interface module's BusAdapter slot and pairs with a BaseUnit BU-Send to begin the extended segment.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6AS00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBA-Send 1x FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom FS05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Cu Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 m; from IM firmware V3.3, between BA-Send and the first ET-Connection bus node and between all other bus nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Interfaces, ET Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFC (FastConnect)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 69.5 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623404569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBA-Send starts an ET-Connection segment, the cabled link that lets an ET 200SP station's I\/O modules be physically split and mounted apart from the interface module, useful when panel space or field layout does not allow all modules on one contiguous DIN rail run. Each hop on the Cu FastConnect cable, including the first one from BA-Send, is limited to 15 m from IM firmware V3.3 onward, so the total split distance depends on how many bus nodes are chained. It requires a matching BaseUnit BU-Send on the same slot to physically start the segment.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSplitting an ET 200SP station across separate mounting locations, for example the interface module and first I\/O group in one cabinet with an additional I\/O group up to 15 m away, via the ET-Connection cabled extension.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540717339,"sku":"6ES7193-6AS00-0AA0","price":131.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6as00-0aa0-ba-send-busadapter.png?v=1789781315"},{"product_id":"siemens-6es7193-6bn00-0ne0-bu-send-baseunit","title":"Siemens 6ES7193-6BN00-0NE0 ET 200SP BaseUnit BU-Send Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BN00-0NE0 is a SIMATIC ET 200SP BaseUnit (BU-Send) used to start a station-split expansion via the ET-Connection cabled link, mounting the BA-Send BusAdapter on a single I\/O slot. It measures 20 mm wide by 117 mm high and mounts directly on the DIN rail alongside the other station BaseUnits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BN00-0NE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efrom FS04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Vertical Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047623404552\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBU-Send provides the single slot the BA-Send BusAdapter plugs into to begin an ET-Connection cabled segment; it carries no supply or bus circuitry of its own, since that function lives entirely in the BA-Send module mounted on it. Pair it with the matching BA-Send BusAdapter 6ES7193-6AS00-0AA0; it is not usable with a standard I\/O module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMechanical starting point on the DIN rail for an ET-Connection station-split segment on a SIMATIC ET 200SP station, used together with the BA-Send BusAdapter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960540913947,"sku":"6ES7193-6BN00-0NE0","price":65.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-product-image-coming-soon_b373f8c8-ef6d-4a50-9c87-2d3e11f0aec0.png?v=1789640012"},{"product_id":"siemens-6es7193-6bp00-0ba0-baseunit-type-a0-bridged","title":"Siemens 6ES7193-6BP00-0BA0 SIMATIC ET 200SP BaseUnit BU15-P16+A0+2B Type A0 24V DC Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0BA0 is a SIMATIC ET 200SP BaseUnit, type A0, that carries a digital I\/O module on a 24 V DC potential group bridged in from the terminal to its left. It provides 16 push-in process terminals across a 15 x 117 mm footprint and passes up to 10 A on the P1\/P2 backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW functional status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom FS06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\/10 A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinued from the left (bridged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; Type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26 to 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals to P1\/P2 bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, vertical installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis BaseUnit bridges its potential group in from the terminal on its left, so it shares the 24 V supply and reference potential of the preceding BaseUnit in the row - use it for modules that stay on the same load group as their neighbor. Pick a new-potential-group BaseUnit instead when a module needs its own fresh 24 V group at that position, for example downstream of outputs that must be individually fused or isolated. The push-in terminals accept 0.14-2.5 mm² (AWG 26-14) conductors, and the 10 A external circuit breaker requirement on the supply line sets the practical current ceiling for the whole potential group, not just this base.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMounts in a SIMATIC ET 200SP station to carry a Type A0 digital I\/O module (16 process terminals) sharing a bridged 24 V DC potential group with the adjacent station position - typical in mixed digital I\/O racks where several modules run off one supply feed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960541110555,"sku":"6ES7193-6BP00-0BA0","price":18.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0ba0-baseunit-type-a0-bridged.png?v=1789662596"},{"product_id":"siemens-6es7193-6bp00-0ba1-baseunit-a1-bridged","title":"Siemens 6ES7193-6BP00-0BA1 SIMATIC ET 200SP BU15-P16+A0+2B\/T BaseUnit Type A1 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0BA1 is a SIMATIC ET 200SP BaseUnit type A1 (BU15-P16+A0+2B\/T) for mounting one I\/O module with 16 push-in process terminals, rated 24 V DC and up to 10 A on the P1\/P2 potential bus. It includes a temperature sensor and bridges the incoming potential group to the left.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eBU type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots\u003c\/td\u003e\n\u003ctd\u003e1 (Type A1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, process terminals, max.\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended external protection\u003c\/td\u003e\n\u003ctd\u003e24 V DC\/10 A MCB, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of process terminals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential group formation\u003c\/td\u003e\n\u003ctd\u003eContinued from the left (bridged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, horizontal install\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, vertical install\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e15 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eType A1 accepts a 16-terminal I\/O module such as a 16-channel digital output module in the same station. The bridged potential-group formation continues the incoming 24 V feed from the adjacent BaseUnit rather than starting a fresh one - pick a new-load-group BaseUnit variant instead at a point in the station where a separate 24 V feed and fusing must begin. The built-in temperature sensor lets the paired I\/O module read local ambient temperature without an added sensor module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePhysical mounting and wiring base for ET 200SP digital or analog I\/O modules in a distributed control cabinet, used where the module continues the same 24 V potential group as its neighbors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960541471003,"sku":"6ES7193-6BP00-0BA1","price":25.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0ba1-et200sp-baseunit-a1.png?v=1789663065"},{"product_id":"siemens-6es7193-6bp00-0bu0-et200sp-baseunit-u0","title":"Siemens 6ES7193-6BP00-0BU0 SIMATIC ET 200SP BaseUnit Type U0 BU20-P16+A0+2B Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0BU0 is a SIMATIC ET 200SP BaseUnit type U0 (BU20-P16+A0+2B) that provides push-in terminal connections for I\/O modules on the ET 200SP backplane, rated 120 V DC or up to 277 V AC per process terminal, and bridged to the BaseUnit on its left to continue the existing potential group. It carries 10 A and measures 20 x 117 mm (W x H).\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0BU0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type U0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V, P1\/P2 bus, AUX bus, process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e277 V, P1\/P2 bus, AUX bus; up to 480 V L1-L2-L3, 277 V L-N at process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A up to 60C, all buses and process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Terminals to I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals to P1\/P2 Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinued from the BaseUnit on the left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30C to 60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eType U0 is a bridged BaseUnit - it continues the potential group from the BaseUnit mounted to its left instead of starting a new one, so use it mid-station where modules share the same supply zone as their neighbor, and reserve a load-group-starting type for the point where a new voltage domain begins. The 120 V DC \/ up to 277 V AC (480 V L-L) rating and 16 process terminals fit modules that need more I\/O points per slot than the smaller 6-terminal BaseUnits.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMid-station potential-group continuation in an ET 200SP station, a mounting slot for digital I\/O modules needing 16 process terminals, and 120\/277 V class distributed I\/O in North American voltage systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960541667611,"sku":"6ES7193-6BP00-0BU0","price":26.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0bu0-et200sp-baseunit.png?v=1789664296"},{"product_id":"siemens-6es7193-6bp00-0da0-baseunit-type-a0-new-group","title":"Siemens 6ES7193-6BP00-0DA0 SIMATIC ET 200SP BaseUnit BU15-P16+A0+2D Type A0 New Potential Group Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0DA0 is a SIMATIC ET 200SP BaseUnit, type A0, that starts a new 24 V DC potential group at its position instead of bridging power in from the left. It integrates a mains filter, provides 16 push-in process terminals on a 15 x 117 mm footprint, and carries up to 10 A on the P1\/P2 backplane bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0DA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW functional status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom FS06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\/10 A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew potential group started here\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation between groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; Type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26 to 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals to P1\/P2 bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, vertical installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis BaseUnit opens a new 24 V DC potential group at its slot, with an integrated mains filter and potential separation from the group upstream - use it wherever an I\/O module needs its own supply reference, for example after a block of relay or inductive-load outputs that should not share transients with the rest of the station. Pick a bridged-group BaseUnit instead when the module can share the existing 24 V feed from its neighbor. Terminal layout (16 push-in process terminals, 0.14-2.5 mm² conductors) and the Type A0 slot match the rest of the A0 family, so modules move between the two potential-group styles without rewiring changes to the module itself.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eStarts a fresh, filtered 24 V DC potential group inside a SIMATIC ET 200SP station - used ahead of I\/O modules that must be electrically segmented from earlier stations in the row, such as noisy output groups or modules fed from a separate power supply branch.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960541700379,"sku":"6ES7193-6BP00-0DA0","price":31.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0da0-baseunit-type-a0-new-group.png?v=1789662602"},{"product_id":"siemens-6es7193-6bp00-0da1-baseunit-a1-new-group","title":"Siemens 6ES7193-6BP00-0DA1 SIMATIC ET 200SP BU15-P16+A0+2D\/T BaseUnit Type A1 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0DA1 is a SIMATIC ET 200SP BaseUnit type A1 (BU15-P16+A0+2D\/T) for mounting one I\/O module with 16 push-in process terminals, rated 24 V DC and up to 10 A on the P1\/P2 potential bus. It starts a new, electrically separated potential group and includes a temperature sensor for local diagnostics.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0DA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eBU type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots\u003c\/td\u003e\n\u003ctd\u003e1 (Type A1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, process terminals, max.\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended external protection\u003c\/td\u003e\n\u003ctd\u003e24 V DC\/10 A MCB, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of process terminals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential group formation\u003c\/td\u003e\n\u003ctd\u003eNew potential group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation between groups\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, horizontal install\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, vertical install\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e15 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis BaseUnit starts a fresh, electrically separated potential group rather than continuing the incoming one - use it at a break point where a different zone needs its own 24 V feed and fusing. A bridged-continuation BaseUnit variant in the same A1 slot type continues the existing potential group instead when no new feed is required. Both variants accept the same 16-terminal Type A1 I\/O modules, so the choice is purely about potential-group segmentation, not I\/O compatibility.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eForming a new 24 V potential and fusing zone within an ET 200SP station, for example separating machine sections for isolated fault protection.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960543469851,"sku":"6ES7193-6BP00-0DA1","price":38.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0da1-et200sp-baseunit-a1.png?v=1789663071"},{"product_id":"siemens-6es7193-6bp00-0du0-et-200sp-bu20-type-u0-baseunit","title":"Siemens 6ES7193-6BP00-0DU0 SIMATIC ET 200SP BU20-P16+A0+2D Type U0 BaseUnit","description":"\u003cp\u003eThe Siemens 6ES7193-6BP00-0DU0 is a SIMATIC ET 200SP BaseUnit, type BU20-P16+A0+2D (BU-TYPE U0), that carries push-in terminals for one I\/O module slot and opens a new potential group on the station's P1\/P2 bus. Rated current is 10 A per bus and per process terminal, with push-in terminals sized for 0.14-2.5 mm² conductors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP00-0DU0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type U0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A max, P1\/P2 bus, AUX bus, and process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 120 V, see manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 277 V, see manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew potential group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in, 0.14-2.5 mm² (1.5 mm² with ferrule)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to I\/O module, 2 to P1\/P2 bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested at 3100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (horizontal install)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe BU-TYPE U0 designation and new potential group flag mean this BaseUnit breaks the power bus into a fresh isolated section, so it belongs at a point in the ET 200SP station where a downstream I\/O module needs a different supply or protection zone than the modules upstream. The push-in terminal set (16 process terminals, no AUX terminals) suits standard I\/O modules without their own auxiliary voltage requirement; pick a BaseUnit variant with AUX terminals instead for modules that need a separate load or sensor supply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eProvides the mounting slot, bus connection, and potential-group break for a single ET 200SP I\/O module in a modular distributed I\/O station.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960543994139,"sku":"6ES7193-6BP00-0DU0","price":39.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp00-0du0-et-200sp-bu20-type-u0-baseunit.png?v=1789664058"},{"product_id":"siemens-6es7193-6bp20-0ba0-baseunit-bu15-p16-a10-2b","title":"Siemens 6ES7193-6BP20-0BA0 SIMATIC ET 200SP BaseUnit BU15-P16+A10+2B Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0BA0 is a SIMATIC ET 200SP BaseUnit type A0 (BU15-P16+A10+2B) with push-in terminals for 0.14 to 2.5 mm² (AWG 26-14) conductors. It provides 16 process terminals to the I\/O module plus 10 AUX terminals bridged to the left, rated 10A on the P1\/P2 and AUX bus while process terminals carry up to 2A, and it operates from -30 to 60 °C horizontal mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A0 (BU15-P16+A10+2B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess terminals to I\/O module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAUX bus terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, bridged to the left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1\/P2 bus terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 and AUX bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal protection for power supply lines\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC \/ 10A MCB, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 141 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe AUX bus terminals are bridged to the left, so the potential group carries through from the preceding BaseUnit without a separate jumper - relevant when several BU type A0 slots in a row need to share the same AUX potential. The push-in terminals accept 0.14 to 2.5 mm² (AWG 26-14), the usual range for ET 200SP field wiring, and the 16 process terminals match a standard 8-channel BU type A0 I\/O module (8 signal + 8 return\/QI, depending on module type).\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMounting base for any BU type A0 I\/O module in an ET 200SP station where AUX terminal access is needed for shield, PE, or potential-group wiring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960544190747,"sku":"6ES7193-6BP20-0BA0","price":23.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0ba0-baseunit-bu15-p16-a10-2b.png?v=1789662878"},{"product_id":"siemens-6es7193-6bp20-0bb0-et200sp-baseunit-b0","title":"Siemens 6ES7193-6BP20-0BB0 SIMATIC ET 200SP BaseUnit Type B0 20mm Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0BB0 is a SIMATIC ET 200SP BaseUnit type B0 (BU20-P12+A4+0B) that carries the P1\/P2 backplane bus and 4 AUX terminals to a single I\/O module slot, rated 24 V DC or 230 V AC with up to 10 A on the P1\/P2 and AUX bus and 5 A on its 12 push-in process terminals. It measures 20 x 117 x 35 mm and weighs 48 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type B0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, P1\/P2 bus (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, P1\/P2 bus (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, AUX bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity, P1\/P2 bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity, AUX bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity, process terminals, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, push-in, per slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAUX Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, bridged to the left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential Separation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane bus \/ supply voltage: Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Tested With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Installation Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515082057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eType B0 carries 4 AUX terminals bridged to the left and 12 push-in process terminals per slot, which distinguishes it from BaseUnit types that route AUX to the right or provide a different terminal count, so match the type letter to the I\/O module's terminal requirement before ordering. The 10 A P1\/P2 and AUX bus rating and 5 A process-terminal rating cap what can be drawn through this specific BaseUnit regardless of the I\/O module plugged into it, so size the station's power budget against that 10 A bus limit across all BaseUnits sharing the potential group.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eForms the mounting and wiring base for a single I\/O module position in a SIMATIC ET 200SP distributed I\/O station, carrying the P1\/P2 backplane bus and AUX potential group to that slot.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960544387355,"sku":"6ES7193-6BP20-0BB0","price":25.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0bb0-et200sp-baseunit-b0.png?v=1789665023"},{"product_id":"siemens-6es7193-6bp20-0bb1-baseunit-b1","title":"Siemens 6ES7193-6BP20-0BB1 SIMATIC ET 200SP BaseUnit BU20-P12+A0+4B Type B1 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0BB1 is a SIMATIC ET 200SP BaseUnit, type B1, that supplies one I\/O module slot with push-in terminals rated up to 10 A on the P1\/P2 potential group and 5 A per process terminal. It carries 24 V DC or 230 V AC depending on the module installed and isolates the backplane bus from the supply voltage, letting the user start a new potential group at this slot.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, P1\/P2 bus (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, P1\/P2 bus (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage, AUX bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V \/ 230 V, equal potential group to P1\/P2 bus or PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, AUX bus, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm2 (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of process terminals to I\/O module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation, backplane bus \/ supply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eType B1 is delivered without auxiliary terminals and bridged to the left, so it continues the AUX-bus potential group of the preceding BaseUnit instead of starting a new one; pick an unbridged or isolating BaseUnit type instead when the station design needs to break the AUX-bus group at this slot. With 12 push-in process terminals and a 10 A P1\/P2 rating, it accepts standard (non fail-safe) ET 200SP I\/O modules with normal current draw; higher-current modules should be checked against this BaseUnit's 5 A per-terminal limit before assignment.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eCarrying a standard ET 200SP digital or analog I\/O module in a station where the AUX-bus potential group should continue unbroken from the neighboring slot, with push-in field wiring for the fastest terminal assembly.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960544846107,"sku":"6ES7193-6BP20-0BB1","price":25.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0bb1-baseunit-type-b1.png?v=1789715771"},{"product_id":"siemens-6es7193-6bp20-0bc1-et200sp-baseunit-c1","title":"Siemens 6ES7193-6BP20-0BC1 SIMATIC ET 200SP BaseUnit Type C1 BU20-P6+A2+4B Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0BC1 is a SIMATIC ET 200SP BaseUnit Type C1 (BU20-P6+A2+4B) that mounts one I\/O module on the mounting rail and connects it to the P1\/P2 backplane bus and AUX bus. It has push-in terminals, a 20 mm width, and carries up to 10 A on the backplane bus per module slot.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515082040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eBU type C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot type\u003c\/td\u003e\n\u003ctd\u003eType C1, 1 module slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage, P1\/P2 and AUX bus\u003c\/td\u003e\n\u003ctd\u003e24 V DC or 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage, process terminals\u003c\/td\u003e\n\u003ctd\u003e24 V DC or 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, backplane bus\u003c\/td\u003e\n\u003ctd\u003e10 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, process terminals\u003c\/td\u003e\n\u003ctd\u003e5 A max. (10 A on terminals 5 and 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of process terminals to I\/O module\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic encoding\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation, backplane bus \/ supply\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation, process terminals \/ supply\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e3100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, horizontal installation\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, vertical installation\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e47 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe Type C1 slot width (20 mm) and 16 process terminals fit ET 200SP modules that need up to 16 process connections in one slot, such as digital I\/O modules with wide channel counts. The dual voltage rating (24 V DC or 230 V AC on the same BaseUnit) means the same part number covers both DC and AC field wiring, so stock one BaseUnit type instead of separate DC and AC variants. Choose a narrower BaseUnit type only when the plugged-in module needs fewer than 16 process terminals and rail space is tight.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960545141019,"sku":"6ES7193-6BP20-0BC1","price":25.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0bc1-et200sp-baseunit-c1.png?v=1789781323"},{"product_id":"siemens-6es7193-6bp20-0bf0-et200sp-baseunit-f0","title":"Siemens 6ES7193-6BP20-0BF0 SIMATIC ET 200SP BaseUnit BU20-P8+A4+0B Type F0","description":"\u003cp\u003eThe Siemens SIMATIC ET 200SP BaseUnit (6ES7193-6BP20-0BF0) is a type F0 push-in base unit, 20 mm wide, that carries one I\/O module slot with 4 auxiliary terminals bridged to the left for the ET 200SP distributed I\/O station. It carries 10 A on the P1\/P2 and AUX backplane buses, 5 A at the process terminals, and measures 20 x 117 x 35 mm at 0.057 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0BF0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type F0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, up to 60 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, P1\/P2 bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, AUX bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent carrying capacity, process terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential separation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane bus \/ supply voltage; process terminals \/ supply voltage; power bus \/ supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation tested with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, horizontal installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth x Height x Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.057 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4 bridged AUX terminals on the left let this base unit share an auxiliary potential, such as a second load voltage, with the adjacent module without extra wiring, unlike plain type F0 base units without the auxiliary-terminal option. Its 10 A P1\/P2 bus rating matches the standard ET 200SP backplane bus current, so it doesn't limit the string unless the process terminals are pushed past their 5 A rating.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eAdds a single digital or analog I\/O module to an ET 200SP station where the module also needs a shared auxiliary potential distributed to neighboring slots.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960545435931,"sku":"6ES7193-6BP20-0BF0","price":25.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0bf0-et200sp-baseunit-f0.png?v=1789663206"},{"product_id":"siemens-6es7193-6bp20-0da0-et200sp-baseunit","title":"Siemens 6ES7193-6BP20-0DA0 SIMATIC ET 200SP BaseUnit BU15 Type A0 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0DA0 is a SIMATIC ET 200SP BaseUnit, type A0, model BU15-P16+A10+2D, that starts a new potential group on the station. It provides push-in terminals for 16 process connections and 10 AUX-bus terminals, rated 10A on the P1\/P2 and AUX bus and 2A per process terminal, so one BaseUnit both isolates the module electrically and starts a fresh load group downstream.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0DA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eBU type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots\u003c\/td\u003e\n\u003ctd\u003e1, type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Protection\u003c\/td\u003e\n\u003ctd\u003e24V DC \/ 10A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Carrying Capacity (P1\/P2 Bus)\u003c\/td\u003e\n\u003ctd\u003e10 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Carrying Capacity (AUX Bus)\u003c\/td\u003e\n\u003ctd\u003e10 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Carrying Capacity (Process Terminals)\u003c\/td\u003e\n\u003ctd\u003e2 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential Group\u003c\/td\u003e\n\u003ctd\u003eNew potential group, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e0.14 to 2.5 mm² (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Process Terminals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of AUX Terminals\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e707 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e15 x 141 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis BU15-P16+A10+2D variant starts a new potential group, so use it where the next I\/O module needs isolation from the previous load group's 24V supply rather than continuing it. It provides 10 AUX-bus terminals for wiring sensor supplies or third-wire signals alongside the 16 process terminals, and the 10A P1\/P2 and AUX bus rating, protected externally by a 10A type B\/C breaker, sets the group's current budget before the next new-potential-group BaseUnit is needed.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLoad-group segmentation and I\/O module mounting on SIMATIC ET 200SP stations where a module needs its own 24V potential group and AUX-bus wiring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960545730843,"sku":"6ES7193-6BP20-0DA0","price":36.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0da0-et200sp-baseunit.png?v=1789663836"},{"product_id":"siemens-6es7193-6bp20-0dc0-et200sp-baseunit-c0","title":"Siemens 6ES7193-6BP20-0DC0 SIMATIC ET 200SP BaseUnit Type C0 BU20-P6+A2+4D Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6BP20-0DC0 is a SIMATIC ET 200SP BaseUnit type C0 (BU20-P6+A2+4D) that provides push-in terminal connections for I\/O modules on the ET 200SP backplane, rated 24 V DC or 230 V AC and 10 A current carrying capacity. It includes 2 AUX terminals in a new load group and measures 20 x 117 mm (W x H), starting a new potential group for load segmentation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP20-0DC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type C0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V, P1\/P2 bus, AUX bus, process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, P1\/P2 bus, AUX bus, process terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A up to 60C; 5 A per process terminal, 10 A on terminals 5 and 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm2, AWG 26-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Terminals to I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential Separation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane bus\/supply voltage; process terminals\/supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Horizontal Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30C to 60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 117 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC51\/CC52 process terminals, CC84-CC86 AUX terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBU20-P6+A2+4D (type C0) starts a new load group and adds 2 AUX terminals, so this slot's process supply can be isolated from the BaseUnits upstream of it. Pick it over a bridged BaseUnit when a downstream module needs a separate voltage or potential domain, such as isolating a noisy actuator circuit or stepping from a 24 V DC zone to a 230 V AC zone. Since the slot itself supports both DC and AC rated values, confirm the connected I\/O module's own voltage class before wiring 230 V.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePotential-group segmentation within an ET 200SP station, a mounting slot for analog or digital I\/O modules that need an isolated process supply, and mixed-voltage-zone distributed I\/O stations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960546058523,"sku":"6ES7193-6BP20-0DC0","price":43.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp20-0dc0-et200sp-baseunit.png?v=1789664303"},{"product_id":"siemens-6es7193-6bp40-0ba1-et200sp-baseunit-bu15-type-a1","title":"Siemens 6ES7193-6BP40-0BA1 SIMATIC ET 200SP BaseUnit BU15-P16+A0+12B\/T Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens SIMATIC ET 200SP BaseUnit BU15-P16+A0+12B\/T 6ES7193-6BP40-0BA1 is a type A1 base unit with 16 push-in process terminals, 2x5 add-on terminals bridged to the left, and integrated temperature acquisition. It carries the P1\/P2 potential bus forward from the base unit to its left and is rated 10 A on the bus, 2 A per process terminal.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP40-0BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eBU type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHW functional status\u003c\/td\u003e\n\u003ctd\u003eFS10 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal protection required\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 10 A miniature circuit breaker, type B or C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, P1\/P2 bus, max.\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent carrying capacity, process terminals, max.\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional terminals\u003c\/td\u003e\n\u003ctd\u003eYes, 2x5 add-on terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential group continued from left\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots\u003c\/td\u003e\n\u003ctd\u003e1, type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation test voltage\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e0.14 ... 2.5 mm2 (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of process terminals\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, horizontal install\u003c\/td\u003e\n\u003ctd\u003e-30 ... 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, vertical install\u003c\/td\u003e\n\u003ctd\u003e-30 ... 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude, max.\u003c\/td\u003e\n\u003ctd\u003e5,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e15 x 141 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eType A1 fixes which I\/O modules this BaseUnit accepts; match it to an A1-type I\/O module rather than the wider A0 BaseUnit family. The built-in temperature sensor and the 2x5 add-on terminals distinguish this BU15 variant from a plain BU15 without additional terminals, so use it where the module needs local temperature acquisition or extra terminal points beyond the 16 process terminals.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960546189595,"sku":"6ES7193-6BP40-0BA1","price":30.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp40-0ba1-et200sp-baseunit-bu15.png?v=1789678970"},{"product_id":"siemens-6es7193-6bp40-0da1-et200sp-baseunit-type-a1","title":"Siemens 6ES7193-6BP40-0DA1 SIMATIC ET 200SP BaseUnit BU15-P16+A0+12D\/T Type A1 Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens SIMATIC ET 200SP BaseUnit BU15-P16+A0+12D\/T (6ES7193-6BP40-0DA1) is a Type A1 base unit with push-in terminals, 2x5 add-on terminals, and integrated temperature-sensor wiring, starting a new potential group at 24 V DC \/ 10 A. It carries the I\/O module plugged into slot 1 and passes P1\/P2 bus power to the next base unit in the ET 200SP station.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6BP40-0DA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBU type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHW Functional Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFS10 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity, P1\/P2 Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Carrying Capacity, Process Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, Type A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14-2.5 mm2 (AWG 26-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdd-On Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotential Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew potential group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temp., Horizontal Install\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temp., Vertical Install\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 x 141 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.059 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis Type A1 base unit starts a new potential group, isolated at 707 V DC type-test, and adds 2x5 extra terminals plus temperature-sensor wiring that a plain Type A1 base unit without AUX\/temperature terminals does not provide - choose it where the I\/O module needs external temperature-compensation wiring or where the panel design calls for a fresh 24 V DC potential group at this point in the station. The 10 A P1\/P2 bus rating and 2 A per process-terminal rating set the load the base unit can carry to downstream stations and field wiring respectively.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBuilding out an ET 200SP remote I\/O station where a module needs its own potential group, added terminals for auxiliary wiring, or temperature-sensor connections - common on analog\/RTD input modules and mixed digital I\/O racks in distributed control cabinets.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960546615579,"sku":"6ES7193-6BP40-0DA1","price":44.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6bp40-0da1-et200sp-baseunit-type-a1.png?v=1789664690"},{"product_id":"siemens-6es7193-6ef00-1aa0-et200sp-e-coding-elements-type-f","title":"Siemens 6ES7193-6EF00-1AA0 SIMATIC ET 200SP E-Coding Elements Type F 5-Pack Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6EF00-1AA0 is a SIMATIC ET 200SP spare part: a pack of 5 E-coding elements, type F, used to mechanically code the slots of F-DI, F-DQ, and F-PM-E fail-safe modules so a module can only be inserted into a matching-coded position. The package weighs 11 g and ships as a keying accessory, not an electronic module.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6EF00-1AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-coding element type F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMechanical slot coding for SIMATIC ET 200SP fail-safe modules - F-DI, F-DQ, and F-PM-E - to prevent a module from being inserted into the wrong station position after configuration.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960547795227,"sku":"6ES7193-6EF00-1AA0","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6ef00-1aa0-et200sp-e-coding-elements-type-f.png?v=1789715035"},{"product_id":"siemens-6es7193-6pa00-0aa0-et200sp-server-module","title":"Siemens 6ES7193-6PA00-0AA0 SIMATIC ET 200SP Server Module 7mm DIN Rail Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-6PA00-0AA0 is a server module for the SIMATIC ET 200SP remote I\/O station, mounted on a 7.5 mm or 15 mm DIN rail. It draws a maximum of 30 mA and operates from -30°C to 60°C horizontally (-30°C to 50°C vertically), in a 7 mm wide, 117 mm tall, 36 mm deep housing that weighs approximately 19 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-6PA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServer module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting rail 7.5 mm and 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Installation Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDew Point, min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515080947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.023 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6ES7193-6PA00-0AA0 fits both 7.5 mm and 15 mm DIN rail profiles, so it drops into existing ET 200SP racks without a rail swap. Vertical mounting derates the upper ambient limit from 60°C to 50°C, which matters when the module sits in a control cabinet with limited convection. At 19 g and 7 mm wide, it adds negligible depth to a station assembly.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a spare or replacement server module in SIMATIC ET 200SP distributed I\/O stations, alongside the interface module in PROFINET-connected remote I\/O installations in switchgear and process cabinets.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960549073179,"sku":"6ES7193-6PA00-0AA0","price":47.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-6pa00-0aa0-et200sp-server-module.png?v=1789665029"},{"product_id":"siemens-6es7193-7aa00-0aa0-et200isp-tm-im-em60s","title":"Siemens 6ES7193-7AA00-0AA0 SIMATIC ET 200iSP TM-IM\/EM60S Screw Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7AA00-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-IM\/EM60S, that holds the IM152-1 interface module plus one electronic module in a single slot pair. It uses screw terminals, includes the power bus termination module, and carries ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings for hazardous-area installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7AA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-IM\/EM60S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (IM152-1 + 1 electronic module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb; II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb; I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 2242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002881\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e235 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-IM\/EM60S pairs the IM152-1 interface module with one electronic module in a single terminal block, so it fits stations where only one I\/O module is needed per IM152-1. The screw terminals suit installations where field wiring is re-terminated occasionally; pick the spring-loaded version instead for faster initial wiring on new panel builds. Its Ex eb [ia Ga\/ib] IIC T4 Gb rating covers Zone 1 gas and Zone 21 dust areas without an additional Ex enclosure around the terminal block itself.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960549957915,"sku":"6ES7193-7AA00-0AA0","price":159.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7aa00-0aa0-et200isp-tm-im-em60s.png?v=1789781329"},{"product_id":"siemens-6es7193-7aa10-0aa0-et200isp-tm-im-em60c","title":"Siemens 6ES7193-7AA10-0AA0 SIMATIC ET 200iSP TM-IM\/EM60C Spring Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7AA10-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-IM\/EM60C, that holds the IM152-1 interface module plus one electronic module in a single slot pair. It uses spring-loaded terminals, includes the power bus termination module, and carries ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings for hazardous-area installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7AA10-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-IM\/EM60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eSpring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (IM152-1 + 1 electronic module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb; II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb; I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 2242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002881\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e235 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-IM\/EM60C pairs the IM152-1 interface module with one electronic module in a single terminal block, the same slot configuration as the screw-terminal TM-IM\/EM60S. Spring terminals cut wiring time on new panel builds and hold up better under vibration than screw terminals, so pick this version for OEM machine builds rather than for field-serviced installations that are re-terminated often. Its Ex eb [ia Ga\/ib] IIC T4 Gb rating covers Zone 1 gas and Zone 21 dust areas.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960550351131,"sku":"6ES7193-7AA10-0AA0","price":159.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7aa10-0aa0-et200isp-tm-im-em60c.png?v=1789781335"},{"product_id":"siemens-6es7193-7ab00-0aa0-et200isp-tm-im-im","title":"Siemens 6ES7193-7AB00-0AA0 SIMATIC ET 200iSP TM-IM\/IM Redundant Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7AB00-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-IM\/IM, built to hold two IM152-1 interface modules for redundant station operation. It includes the power bus termination module and carries ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings, so a station built on this terminal module keeps running if one IM152-1 fails.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7AB00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-IM\/IM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (redundant IM152-1 pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb; II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb; I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 2242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002881\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e195 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-IM\/IM is the only terminal module in this group built for two IM152-1 units instead of one IM152-1 plus an electronic module, so choose it specifically for redundant interface-module stations, not for standard single-IM152-1 stations. At 195 g it is lighter than the single-IM\/EM variants because it carries no electronic-module slot logic. Use it where a lost IM152-1 must not take the whole ET 200iSP station offline.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960551006491,"sku":"6ES7193-7AB00-0AA0","price":228.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7ab00-0aa0-et200isp-tm-im-im.png?v=1789781341"},{"product_id":"siemens-6es7193-7ca00-0aa0-et200isp-tm-em-em60s","title":"Siemens 6ES7193-7CA00-0AA0 SIMATIC ET 200iSP TM-EM\/EM60S Screw Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7CA00-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-EM\/EM60S, that holds two electronic modules in a single terminal block without an IM152-1 slot. It uses screw terminals and carries ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings, letting a station add I\/O capacity to an existing IM152-1 interface module instead of starting a new station.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7CA00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131742\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-EM\/EM60S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (two electronic modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb; II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb; I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 2242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002881\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e275 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-EM\/EM60S carries two electronic modules with no IM152-1 slot, so use it to extend an existing ET 200iSP station rather than to start a new one. The screw terminals suit panels where wiring is checked or re-terminated during commissioning; the spring-loaded EM60C version is the faster-to-wire alternative for repeat machine builds. At 275 g it is the heaviest of the two-module terminal blocks in this group.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960551694619,"sku":"6ES7193-7CA00-0AA0","price":128.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7ca00-0aa0-et200isp-tm-em-em60s.png?v=1789781347"},{"product_id":"siemens-6es7193-7ca10-0aa0-et200isp-tm-em-em60c","title":"Siemens 6ES7193-7CA10-0AA0 SIMATIC ET 200iSP TM-EM\/EM60C Spring Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7CA10-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-EM\/EM60C, that holds two electronic modules in a single terminal block without an IM152-1 slot. It uses spring-loaded terminals and carries ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings, letting a station add I\/O capacity to an existing IM152-1 interface module instead of starting a new station.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7CA10-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169131759\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-EM\/EM60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eSpring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (two electronic modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX marking\u003c\/td\u003e\n\u003ctd\u003eII 2 G (1) G Ex eb [ia Ga\/ib] IIC T4 Gb; II 2 G (1) D Ex eb [ia IIIC Da] IIC T4 Gb; I M2 Ex eb [ia\/ib] I Mb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 04 ATEX 2242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 05.0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002881\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e323 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-EM\/EM60C is the spring-terminal counterpart to TM-EM\/EM60S, same two-electronic-module slot layout with no IM152-1 slot. Spring terminals cut wiring time on new panel builds and hold up better under vibration, so pick this version for OEM machine builds; use the screw-terminal EM60S where wiring is checked or re-terminated during commissioning. At 323 g it is the heaviest terminal module in this group.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960551989531,"sku":"6ES7193-7CA10-0AA0","price":128.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7ca10-0aa0-et200isp-tm-em-em60c.png?v=1789781354"},{"product_id":"siemens-6es7193-7ca20-0aa0-et200isp-tm-em-em60s-black","title":"Siemens 6ES7193-7CA20-0AA0 SIMATIC ET 200iSP TM-EM\/EM60S Black Screw Terminal Module I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7CA20-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-EM\/EM60S in black screw terminals, that holds two electronic modules in a single terminal block without an IM152-1 slot. It has marine approvals from Germanischer Lloyd, ABS, Bureau Veritas, and DNV, and carries a CE 0344 mark for standard industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7CA20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169211833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-EM\/EM60S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (two electronic modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e235 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis black-terminal TM-EM\/EM60S variant has the same two-electronic-module slot layout and current ratings as the standard TM-EM\/EM60S but carries no ATEX\/IECEx hazardous-area certificate in the verified data, so treat it as the general-purpose finish rather than the Ex-rated one. Choose it for standard control-room or marine installations where the black housing matches panel color coding and a Zone 1\/Zone 21 rating is not required.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960552972571,"sku":"6ES7193-7CA20-0AA0","price":118.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7ca20-0aa0-et200isp-tm-em-em60s-black.png?v=1789781360"},{"product_id":"siemens-6es7193-7cb00-0aa0-et200isp-tm-rm-rm","title":"Siemens 6ES7193-7CB00-0AA0 SIMATIC ET 200iSP TM-RM\/RM Screw Terminal Module Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7CB00-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-RM\/RM, that holds two electronic modules with screw terminals rated 0.2-2 mm² conductor cross-section. It carries ATEX certificate KEMA 07 ATEX 0205 and IECEx KEM 07.0060, covering Zone 1 gas and Zone 21 dust hazardous areas without a separate Ex enclosure around the terminal block.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7CB00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169182874\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-RM\/RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e2 (two electronic modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e4 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e0.2-2 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX certificate\u003c\/td\u003e\n\u003ctd\u003eKEMA 07 ATEX 0205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx KEM 07.0060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC Ex certificate\u003c\/td\u003e\n\u003ctd\u003e2020322310002992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE mark\u003c\/td\u003e\n\u003ctd\u003eCE 0344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUKCA mark\u003c\/td\u003e\n\u003ctd\u003eDEKRA 21UKEX0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eLISTED E334384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM approval\u003c\/td\u003e\n\u003ctd\u003eCLASSIFIED 3025852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINMETRO certificate\u003c\/td\u003e\n\u003ctd\u003eUL-BR 12.0079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-RM\/RM uses its own ATEX certificate (KEMA 07 ATEX 0205) and IECEx number (IECEx KEM 07.0060), separate from the TM-EM\/EM60S\/TM-IM\/EM60S family, and takes a smaller 0.2-2 mm² conductor than the 0.14-2.5 mm² range on the IM\/EM terminal modules. At 340 g it is the heaviest terminal module in this group, so budget rail space and weight accordingly when stacking several RM slots in one ET 200iSP station.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960553398555,"sku":"6ES7193-7CB00-0AA0","price":287.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7cb00-0aa0-et200isp-tm-rm-rm.png?v=1789781366"},{"product_id":"siemens-6es7193-7da10-0aa0-et200isp-tm-ps-a","title":"Siemens 6ES7193-7DA10-0AA0 SIMATIC ET 200iSP TM-PS-A 24V DC Power Supply Terminal Module Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7DA10-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-PS-A, built to hold the 24 V DC power supply module (order number 6ES7138-7EA01-0AA0) that feeds an ET 200iSP station. It accepts 19.2-30 V DC input and delivers up to 5 A DC output, with ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7DA10-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169146661\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-PS-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e1 (holds power supply module 6ES7138-7EA01-0AA0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage input\u003c\/td\u003e\n\u003ctd\u003e19.2-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e6 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e5 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse in hazardous areas\u003c\/td\u003e\n\u003ctd\u003eATEX gas Zone 1, ATEX dust Zone 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (net, catalog)\u003c\/td\u003e\n\u003ctd\u003e294 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-PS-A is the standard, non-redundant power-supply terminal module: it holds a single power supply module feeding the whole ET 200iSP station. Choose TM-PS-B in addition when the station needs a redundant power feed, since TM-PS-B mounts alongside TM-PS-A rather than replacing it. Both only accept the 6ES7138-7EA01-0AA0 power supply module, so confirm that module is in the bill of materials before ordering this terminal module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960555954459,"sku":"6ES7193-7DA10-0AA0","price":159.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7da10-0aa0-et200isp-tm-ps-a.png?v=1789781371"},{"product_id":"siemens-6es7193-7da20-0aa0-et200isp-tm-ps-a-uc","title":"Siemens 6ES7193-7DA20-0AA0 SIMATIC ET200iSP TM-PS-A UC Terminal Module Ex Remote I\/O Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7DA20-0AA0 is the TM-PS-A UC terminal module for SIMATIC ET200iSP, holding a 120\/230 V AC power supply module rated up to 6 A input and delivering 24 V DC output at up to 5 A. Certified Ex eb [ia] IIC T4 Gb for ATEX Zone 1 gas and Zone 21 dust areas, it also carries cULus, FM, IECEx, and CCC Ex hazardous-location approvals.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7DA20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM-PS-A UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current, 50\/60 Hz, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection, gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX Zone 1 - Ex eb [ia Ga\/ib] IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection, dust\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX Zone 21 - Ex eb [ia IIIC Da] IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 x 190 x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eINMETRO\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC Ex\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe TM-PS-A UC terminal module carries the ET200iSP power supply's Ex eb [ia Ga\/ib] IIC T4 Gb rating for Zone 1 gas and Ex eb [ia IIIC Da] IIC T4 Gb for Zone 21 dust areas, so it belongs on the intrinsically-safe rail together with Ex-rated field modules rather than a standard, non-hazardous ET200iSP station. Its 85 to 264 V AC input accepts both 120 V and 230 V mains without reconfiguration, and the 5 A DC output at 24 V sizes the downstream I\/O load the station can carry from this slot.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePowering SIMATIC ET200iSP fail-safe and standard I\/O modules inside Zone 1\/21 hazardous-area installations - process automation in oil and gas, chemical, and pharmaceutical plants with marine classification requirements.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960556478747,"sku":"6ES7193-7DA20-0AA0","price":159.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7da20-0aa0-et200isp-tm-ps-a-uc-terminal-module.png?v=1789715041"},{"product_id":"siemens-6es7193-7db10-0aa0-et200isp-tm-ps-b","title":"Siemens 6ES7193-7DB10-0AA0 SIMATIC ET 200iSP TM-PS-B Redundant Power Supply Terminal Module Accessory","description":"\u003cp\u003eThe Siemens 6ES7193-7DB10-0AA0 is a SIMATIC ET 200iSP terminal module, type TM-PS-B, built to hold a second, redundant 24 V DC power supply module (order number 6ES7138-7EA01-0AA0) alongside a TM-PS-A. It accepts 19.2-30 V DC input and delivers up to 5 A DC output, with ATEX\/IECEx Zone 1 gas and Zone 21 dust ratings.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order number\u003c\/td\u003e\n\u003ctd\u003e6ES7193-7DB10-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169146678\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eTM-PS-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFront mounting, rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e1 (holds redundant power supply module 6ES7138-7EA01-0AA0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage input\u003c\/td\u003e\n\u003ctd\u003e19.2-30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current, max.\u003c\/td\u003e\n\u003ctd\u003e6 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e20.4-28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, max.\u003c\/td\u003e\n\u003ctd\u003e5 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse in hazardous areas\u003c\/td\u003e\n\u003ctd\u003eATEX gas Zone 1, ATEX dust Zone 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (net, catalog)\u003c\/td\u003e\n\u003ctd\u003e293 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTM-PS-B only mounts in addition to a TM-PS-A, it does not replace it; order it only when the station needs a redundant power feed rather than a single power supply module. Use it with the same 6ES7138-7EA01-0AA0 power supply module as TM-PS-A so both feeds share identical input\/output ratings, keeping the station powered if one supply module fails.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960556904731,"sku":"6ES7193-7DB10-0AA0","price":228.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7193-7db10-0aa0-et200isp-tm-ps-b.png?v=1789781377"}],"url":"https:\/\/stoklink.com\/collections\/plc-accessories.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}