{"title":"Motor Controller","description":null,"products":[{"product_id":"abb-1sda066460r1-mod-xt1-xt3-220-250v-ac-dc-motor-operator","title":"ABB 1SDA066460R1 MOD XT1-XT3 220...250V ac\/dc Motor Operator for Tmax XT1-XT3 Circuit Breakers","description":"\u003cp\u003eThe ABB 1SDA066460R1 MOD XT1-XT3 220...250V ac\/dc is a motor operator accessory designed for remote electrical operation of ABB Tmax XT1 and XT3 moulded case circuit breakers. This motor operator enables automated opening and closing of the circuit breaker via a 220–250V AC\/DC control signal, making it essential for applications requiring remote switching, supervisory control, or integration into automated power distribution systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD XT1-XT3 220...250V ac\/dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA066460R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT \/ XT1-XT3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Operator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Control Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220...250V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT1, XT3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644692827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Meets requirements of the EU RoHS Directive including the 2015 amendment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Meets the international standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 489:\u003c\/strong\u003e Listed to UL standard for molded-case circuit breakers and circuit breaker enclosures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives and carries the CE marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRemote operation of ABB Tmax XT1 and XT3 circuit breakers in motor control centres (MCCs)\u003c\/li\u003e\n\u003cli\u003eIntegration with SCADA, BMS, or PLC systems for automated load management and switching\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring electrically actuated circuit breaker operation\u003c\/li\u003e\n\u003cli\u003eEnergy management systems where manual breaker operation is impractical or unsafe\u003c\/li\u003e\n\u003cli\u003eBuilding automation and facility management distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229078294811,"sku":"1SDA066460R1","price":270.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda066460r1-mod-xt1-xt3-220-250v-ac-dc-xt1-xt3-circuit-breakers_1eab720b-24ee-4790-9134-27429c42cad1.webp?v=1777157942"},{"product_id":"abb-1sda066466r1-moe-xt2-xt4-220-250v-ac-dc-motor-operator","title":"ABB 1SDA066466R1 MOE XT2-XT4 220...250V ac\/dc Motor Operator for Tmax XT2 XT4 Circuit Breakers","description":"\u003cp\u003eThe ABB \u003cstrong\u003eMOE XT2-XT4 220...250V ac\/dc\u003c\/strong\u003e (SKU: 1SDA066466R1) is a motor operator accessory designed for remote electrical actuation of ABB Tmax XT2 and XT4 moulded case circuit breakers. The \u003cstrong\u003eMOE XT2-XT4 220...250V ac\/dc\u003c\/strong\u003e enables automated open\/close switching of the breaker via a 220–250V AC\/DC control voltage signal, making it ideal for remote operation, building management systems, and industrial automation applications where manual access to the breaker is impractical. Weighing 1.357 kg, it mounts directly onto compatible XT2\/XT4 frames without additional hardware.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOE XT2-XT4 220...250V ac\/dc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA066466R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT (XT2-XT4)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Operator\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220…250V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTmax XT2, Tmax XT4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.357 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644692858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Complies with the international standard for low-voltage circuit breakers and accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 489:\u003c\/strong\u003e Listed to the UL standard for molded-case circuit breakers, ensuring North American market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for safety, health, and environmental protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from lead, mercury, cadmium, and other restricted materials\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote switching of Tmax XT2\/XT4 circuit breakers in motor control centres (MCCs)\u003c\/li\u003e\n  \u003cli\u003eBuilding management and energy management systems requiring automated breaker control\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels where manual breaker access is restricted or hazardous\u003c\/li\u003e\n  \u003cli\u003eGenerator changeover and load-shedding schemes requiring motorised actuation\u003c\/li\u003e\n  \u003cli\u003eProcess industry installations requiring SCADA\/PLC-driven breaker open\/close commands\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229078524187,"sku":"1SDA066466R1","price":544.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda066466r1-moe-xt2-xt4-220-250v-ac-dc-xt4-circuit-breakers_c96d2bff-05ea-4032-b3e5-9fe59894cb4b.webp?v=1777157930"},{"product_id":"abb-1saj590000r0103-umc100-pan-lcd-panel-operator","title":"ABB 1SAJ590000R0103 UMC100-PAN LCD Panel with USB Interface Operator Panel for Motor Management Device","description":"\u003cp\u003eThe ABB UMC100-PAN (1SAJ590000R0103) is an LCD operator panel with USB interface designed for the UMC100.3 Universal Motor Controller, providing door-mounted local control and monitoring of motor management functions. This compact panel — measuring just 50 × 17 × 67 mm and weighing 47 g — replaces the previous 1SAJ590000R0102 and offers engineers a practical front-of-panel interface for commissioning, diagnostics, and parameter configuration directly on the switchboard door.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUMC100-PAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAJ590000R0103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUMC100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperator Panel for Motor Management Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD with USB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDoor Mounted (UMC100.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 × 17 × 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.047 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614496950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAJ590000R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.60947-1:\u003c\/strong\u003e Canadian standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.60947-4-1:\u003c\/strong\u003e Canadian standard for electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — generic immunity standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-4:\u003c\/strong\u003e Electromagnetic compatibility — generic emission standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e EMC generic standards for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-1:\u003c\/strong\u003e UL standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1A:\u003c\/strong\u003e UL standard for AC electromechanical contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.60947:\u003c\/strong\u003e CSA general low-voltage switchgear and controlgear standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL and CSA certification for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU health, safety, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemical safety regulation (EC No 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDoor-mounted local operator interface for ABB UMC100.3 Universal Motor Controllers in MCC panels and switchboards\u003c\/li\u003e\n\u003cli\u003eOn-site commissioning and parameter programming of motor management devices via USB connection\u003c\/li\u003e\n\u003cli\u003eReal-time motor diagnostics and fault display in industrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eMotor protection configuration in pump stations, compressor panels, HVAC systems, and conveyor drives\u003c\/li\u003e\n\u003cli\u003eSuitable for use in hazardous area panels certified to ATEX requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229302821147,"sku":"1SAJ590000R0103","price":283.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1saj590000r0103-umc100-pan-abb-1saj590000r0103-umc100-pan_0bc0fb9b-5b3f-4062-97d0-ef8cf5ec5ca5.webp?v=1777393972"},{"product_id":"abb-1sfa899300r1008-ab-modbus-tcp-2-communication-module","title":"ABB 1SFA899300R1008 AB-MODBUS-TCP-2 ANYBUS Modbus TCP Communication Module","description":"\u003cp\u003eThe ABB \u003cstrong\u003eAB-MODBUS-TCP-2\u003c\/strong\u003e (SKU: 1SFA899300R1008) is an ANYBUS series Modbus TCP communication module designed for seamless integration of ABB devices into industrial Ethernet-based automation networks. Compact and lightweight at just 27 g with dimensions of 50 × 54.81 × 22.25 mm, this module enables reliable Modbus TCP\/IP connectivity in control panel and automation system applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAB-MODBUS-TCP-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SFA899300R1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANYBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.027 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7320500505410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the module is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), confirming safe chemical substance management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive, supporting responsible end-of-life recycling and disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntegrating ABB soft starters, motor controllers, and drives into Modbus TCP\/IP industrial Ethernet networks\u003c\/li\u003e\n\u003cli\u003eControl panel automation and SCADA system connectivity\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation requiring standardised fieldbus communication\u003c\/li\u003e\n\u003cli\u003eBuilding automation and factory automation infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229348565275,"sku":"1SFA899300R1008","price":368.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sfa899300r1008-ab-modbus-tcp-2-fieldbus-communication-module_149a31de-f0a6-4954-862c-8a7470bf299a.webp?v=1777160213"},{"product_id":"schneider-luca12bl-tesys-ultra-3-12a-control-unit","title":"Schneider Electric LUCA12BL TeSys Ultra 3-12A Control Unit for Motor Protection","description":"\u003cp\u003eThe Schneider Electric LUCA12BL is a TeSys Ultra control unit designed for motor protection and industrial automation applications, offering an adjustable current range of 3A to 12A. Part of the TeSys Ultra series, the LUCA12BL integrates advanced motor management functions into a compact module suitable for use in modern control panels and motor starter assemblies. At just 135 g, it is engineered for space-efficient installation in demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA12BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A to 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Provides overload and fault protection for three-phase motors within the 3–12A current range, ideal for small to medium motor loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Integrates seamlessly into TeSys Ultra motor starter assemblies used in manufacturing, process control, and machine building applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact and lightweight design makes the LUCA12BL well-suited for DIN rail-mounted control panel builds requiring reliable motor management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Suitable for OEM machinery where standardised Schneider Electric TeSys Ultra components are specified for motor control and protection circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230472638747,"sku":"LUCA12BL","price":82.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-luca12bl-for-motor-protection_2e7832ec-ba16-4e04-adc5-34a281466c46.jpg?v=1777166482"},{"product_id":"schneider-luca12fu-tesys-ultra-3-12a-control-unit","title":"Schneider Electric LUCA12FU TeSys Ultra Control Unit 3-12A Motor Control","description":"\u003cp\u003eThe Schneider Electric LUCA12FU is a TeSys Ultra series control unit rated for 3 A to 12 A, designed to provide intelligent motor protection and control in industrial automation applications. The LUCA12FU integrates seamlessly into motor starter assemblies, offering precise current adjustment and reliable overload protection for demanding control panel environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA12FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A to 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Provides overload and phase-loss protection for three-phase motors in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for integration into motor starter assemblies within control panels and switchgear enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing \u0026amp; Process Control:\u003c\/strong\u003e Ideal for conveyor systems, pumps, compressors, and fans requiring reliable motor control up to 12 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machinery:\u003c\/strong\u003e Compact design and TeSys Ultra compatibility make the LUCA12FU a preferred choice for machine builders and system integrators.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230472737051,"sku":"LUCA12FU","price":82.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-luca12fu-3-12a-motor-control_15e97193-c1b0-48e5-b15d-d35bf3b026a7.jpg?v=1777166486"},{"product_id":"schneider-luca18bl-tesys-ultra-18a-3p-control-unit","title":"Schneider Electric LUCA18BL TeSys Ultra 4.5–18A 3P Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric LUCA18BL\u003c\/strong\u003e is a TeSys Ultra 3-pole control unit rated for 4.5 A to 18 A, designed for advanced motor management and protection in industrial automation and control panel applications. As part of Schneider Electric's TeSys Ultra series, the LUCA18BL provides reliable motor control functionality suitable for demanding electrical environments where precise current management and system integration are critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA18BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 A to 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Designed for motor management in industrial automation systems, providing adjustable current protection across the 4.5–18 A range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Compact 3-pole design suitable for integration into industrial control panels and motor control centers (MCCs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Ideal for manufacturing, conveyor, pump, and fan applications where reliable motor protection and control are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTeSys Ultra Systems:\u003c\/strong\u003e Functions as a core control unit within Schneider Electric's TeSys Ultra modular motor management platform.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230472868123,"sku":"LUCA18BL","price":84.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-luca18bl-3p-control-unit_2c3c220d-ddb8-4335-a84a-3686968071eb.jpg?v=1777166491"},{"product_id":"schneider-luca32fu-tesys-ultra-8-32a-control-unit","title":"Schneider Electric LUCA32FU TeSys Ultra 8-32A Control Unit for Motor Protection","description":"\u003cp\u003eThe Schneider Electric LUCA32FU is a TeSys Ultra control unit designed for intelligent motor protection and industrial automation applications. Rated for 8 A to 32 A, this control unit integrates seamlessly into motor starter assemblies within control panels, offering reliable overload and phase-failure protection for three-phase motors. Weighing just 135 g, the LUCA32FU is compact and suitable for space-constrained panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA32FU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A to 32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Provides overload and phase-loss protection for three-phase motors in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Designed for integration into automated motor starter assemblies and control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact form factor suits installation in DIN-rail-based motor control centres and enclosed switchgear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industries:\u003c\/strong\u003e Ideal for pumps, fans, compressors, and conveyor drive protection across manufacturing and process plants.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230473687323,"sku":"LUCA32FU","price":105.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-luca32fu-for-motor-protection_b5753768-c1c1-4838-a189-30a830da53b1.jpg?v=1777166496"},{"product_id":"schneider-lucb12bl-lucb-3-12a-tesys-ultra-control-unit","title":"Schneider Electric LUCB12BL LUCB 3P 3-12A TeSys Ultra Control Unit","description":"\u003cp\u003eThe Schneider Electric LUCB12BL is a TeSys Ultra 3-pole control unit rated for 3 A to 12 A, designed for intelligent motor management and protection in industrial automation applications. The LUCB12BL combines motor protection and control functions in a compact unit weighing just 0.119 kg, making it well suited for integration into modern motor starter assemblies and control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB12BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A to 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.119 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Provides intelligent overload and motor protection within TeSys Ultra motor starter assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Ideal for OEM machine builders and system integrators requiring compact, reliable control units in automated production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Suitable for switchboard and control panel installations where space-efficient motor management is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industries:\u003c\/strong\u003e Applicable in manufacturing, water treatment, HVAC, and material handling environments requiring dependable 3-phase motor control.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230474539291,"sku":"LUCB12BL","price":85.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lucb12bl-ultra-control-unit_814c93fc-0a6d-4763-a36a-2d1c46303c1d.jpg?v=1777166500"},{"product_id":"schneider-lucb18fu-lucb-3p-18a-tesys-ultra-control-unit","title":"Schneider Electric LUCB18FU LUCB 3P 4.5-18A TeSys Ultra Control Unit","description":"\u003cp\u003eThe Schneider Electric LUCB18FU is a TeSys Ultra control unit designed for industrial motor protection and automation applications. Identified by model LUCB, this 3-pole unit covers a rated current range of 4.5 A to 18 A, making it suitable for a broad range of motor sizes in control panel installations. Weighing just 122 g, the LUCB18FU integrates seamlessly into TeSys Ultra motor starter assemblies, providing reliable overload and control functions in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB18FU\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 A to 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.122 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking, confirming compliance with applicable UK product safety and regulatory requirements for the Great Britain market.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe LUCB18FU control unit is engineered for integration within TeSys Ultra motor starter assemblies used across a wide range of industrial automation and motor control applications. Typical use cases include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection and control in manufacturing and process automation\u003c\/li\u003e\n  \u003cli\u003eControl panel builds requiring compact, reliable motor management\u003c\/li\u003e\n  \u003cli\u003eHVAC and pumping system motor starters\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling drive protection\u003c\/li\u003e\n  \u003cli\u003eOEM machine builders requiring IEC-compliant motor control solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230474735899,"sku":"LUCB18FU","price":90.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lucb18fu-ultra-control-unit_3dfbd9c6-3637-4dcc-9441-ad7206541026.jpg?v=1777166505"},{"product_id":"schneider-lucb32bl-tesys-ultra-lucc-8-32a-control-unit","title":"Schneider Electric LUCB32BL TeSys Ultra LUCC 3P 8-32A Advanced Control Unit","description":"\u003cp\u003eThe Schneider Electric LUCB32BL is a TeSys Ultra series LUCC advanced control unit designed for industrial motor control and automation applications. This 3-pole unit covers a rated current range of 8 A to 32 A, making it suitable for a wide variety of motor protection and control panel installations. Compact at just 115 g, the LUCB32BL integrates seamlessly into TeSys Ultra motor management systems, delivering reliable performance in demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCB32BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A to 32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets applicable UK product safety and regulatory requirements for the Great Britain market\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230475227419,"sku":"LUCB32BL","price":111.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lucb32bl-advanced-control-unit_414c5332-d4de-4668-a2e7-5cd7cf7c5baa.jpg?v=1777166509"},{"product_id":"siemens-3rk1100-1cq20-0aa3-3rk1-1a-24v-motor-controller","title":"Siemens 3RK1100-1CQ20-0AA3 3RK1 1A 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1100-1CQ20-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K45 digital 4 DQ, IP67 4 x output, 1 A 24 V DC maximal 3 A for all outputs 4 x M12 socket Mounting plate 3RK1901-2EA00 or 3RK1901-2DA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1100-1CQ20-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edigital I\/O modules for operation in the field, IP67 - K45\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2- and 3-wire technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of output voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity of the semiconductor output at DC-13 at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of switching output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNP transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProperty of the output short-circuit proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K45 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.082 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1100-1CQ20-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619967856923,"sku":"3RK1100-1CQ20-0AA3","price":170.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1100-1cq20-0aa3.webp?v=1784372772"},{"product_id":"siemens-3rk1107-0bg00-2aa2-3rk1-motor-controller","title":"Siemens 3RK1107-0BG00-2AA2 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1107-0BG00-2AA2 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i SlimLine Compact module SC22.5, IP20, analog 2AQ-C\/V spring-loaded terminals 2 x analog output outputs switchable C\/V overall width 22.5 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1107-0BG00-2AA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 30 V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 24 V with AS-i Power24V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to EN 61346-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs safety-related\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply at the outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS interface or U_AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal range at analog output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 20 mA; 4 ... 20 mA; +\/- 20 mA; 1 ... 5 V; 0 ... 10 V; +\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function parameterizable output variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor AS-Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor external auxiliary voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew and snap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.179 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1107-0BG00-2AA2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619967889691,"sku":"3RK1107-0BG00-2AA2","price":338.82,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1107-0bg00-2aa2.webp?v=1784372778"},{"product_id":"siemens-3rk1107-1bq40-0aa3-3rk1-motor-controller","title":"Siemens 3RK1107-1BQ40-0AA3 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1107-1BQ40-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 2 AQ, IP67 2 x 1 output, current 0..20 mA,  4..20 mA, +\/- 20 mA for 2-wire actuators 2 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1107-1BQ40-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function parameterizable output variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.185 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1107-1BQ40-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619967955227,"sku":"3RK1107-1BQ40-0AA3","price":415.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1107-1bq40-0aa3.webp?v=1784372784"},{"product_id":"siemens-3rk1107-2bq40-0aa3-3rk1-10v-motor-controller","title":"Siemens 3RK1107-2BQ40-0AA3 3RK1 10V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1107-2BQ40-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 2 AQ, IP67 2x 1 output, Voltage +\/- 10 V 1..5 V for 2-wire actuators 2 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1107-2BQ40-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function parameterizable output variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1107-2BQ40-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619967987995,"sku":"3RK1107-2BQ40-0AA3","price":415.48,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1107-2bq40-0aa3.webp?v=1784372790"},{"product_id":"siemens-3rk1200-0cq20-0aa3-3rk1-motor-controller","title":"Siemens 3RK1200-0CQ20-0AA3 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1200-0CQ20-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K45 digital 4 DI, IP67 4 x input, maximum 200 mA 4 x M12 socket Mounting plate 3RK1901-2EA00 or 3RK1901-2DA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1200-0CQ20-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edigital I\/O modules for operation in the field, IP67 - K45\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply for sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing AS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt ambient temperature 40 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2- and 3-wire technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the input voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.084 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1200-0CQ20-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968053531,"sku":"3RK1200-0CQ20-0AA3","price":142.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1200-0cq20-0aa3.webp?v=1784372797"},{"product_id":"siemens-3rk1200-0dq00-0aa3-3rk1-motor-controller","title":"Siemens 3RK1200-0DQ00-0AA3 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1200-0DQ00-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 digital 8 DI, IP67 8 x inputs, maximum 200 mA 8 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1200-0DQ00-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edigital I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply for sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing AS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt ambient temperature 40 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2- and 3-wire technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the input voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY-II assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY-II assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1200-0DQ00-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968119067,"sku":"3RK1200-0DQ00-0AA3","price":282.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1200-0dq00-0aa3.webp?v=1784372804"},{"product_id":"siemens-3rk1205-0bg00-2aa2-3rk1-motor-controller","title":"Siemens 3RK1205-0BG00-2AA2 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1205-0BG00-2AA2 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. ASIsafe SlimLine Compact module SC17.5F digital safety 2 F-DI, IP20 2 x input for mechanical sensors spring-type terminals Overall width 17.5 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1205-0BG00-2AA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 30 V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 24 V with AS-i Power24V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to EN 61346-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs safety-related\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of input characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emechanical contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePFHD with high demand rate according to IEC 62061\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5E-9 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level (PL) according to EN ISO 13849-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ee\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory according to EN ISO 13849-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to Category 4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Integrity Level (SIL) according to IEC 61508\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePFDavg with low demand rate according to IEC 61508\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5E-6\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe failure fraction (SFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor AS-Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew and snap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.137 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1205-0BG00-2AA2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968151835,"sku":"3RK1205-0BG00-2AA2","price":190.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1205-0bg00-2aa2.webp?v=1784372814"},{"product_id":"siemens-3rk1207-0cg00-2aa2-3rk1-motor-controller","title":"Siemens 3RK1207-0CG00-2AA2 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-0CG00-2AA2 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i SlimLine Compact module SC22.5, IP20, analog, 4AI-C\/V spring-type terminals 4 x analog input Inputs switchable C\/V Overall width 22.5 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-0CG00-2AA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 30 V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 24 V with AS-i Power24V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to EN 61346-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs safety-related\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2- and 4-wire technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply for sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS interface, alternatively U_AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 mA with supply via AS interface \/ 500 mA with supply via Uaux\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal range at the analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ... 20 mA; +\/- 20 mA; 1 ... 5 V; +\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function smoothing parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor AS-Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor external auxiliary voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew and snap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.209 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-0CG00-2AA2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968217371,"sku":"3RK1207-0CG00-2AA2","price":355.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-0cg00-2aa2.webp?v=1784372820"},{"product_id":"siemens-3rk1207-1bq40-0aa3-3rk1-motor-controller","title":"Siemens 3RK1207-1BQ40-0AA3 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-1BQ40-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 2 AI, IP67 2 x input, current 4..20 mA, +\/- 20 mA for 4-wire sensors 2 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-1BQ40-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-1BQ40-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968250139,"sku":"3RK1207-1BQ40-0AA3","price":391.89,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-1bq40-0aa3.webp?v=1784372826"},{"product_id":"siemens-3rk1207-1bq44-0aa3-3rk1-motor-controller","title":"Siemens 3RK1207-1BQ44-0AA3 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-1BQ44-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 4 AI, IP67 4 x input, current 4..20 mA, +\/- 20 mA for 4-wire sensors 4 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-1BQ44-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.192 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-1BQ44-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968282907,"sku":"3RK1207-1BQ44-0AA3","price":450.27,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-1bq44-0aa3.webp?v=1784372832"},{"product_id":"siemens-3rk1207-2bq40-0aa3-3rk1-10v-motor-controller","title":"Siemens 3RK1207-2BQ40-0AA3 3RK1 10V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-2BQ40-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 2 AI, IP67 2 x input, Voltage +\/- 10 V 1..5 V for 4-wire sensors 2 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-2BQ40-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.183 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-2BQ40-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968348443,"sku":"3RK1207-2BQ40-0AA3","price":391.89,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-2bq40-0aa3.webp?v=1784372838"},{"product_id":"siemens-3rk1207-2bq44-0aa3-3rk1-10v-motor-controller","title":"Siemens 3RK1207-2BQ44-0AA3 3RK1 10V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-2BQ44-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 analog 4 AI, IP67 4 x input, Voltage +\/- 10 V 1..5 V for 4-wire sensors 4 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-2BQ44-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eanalog slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput variable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard rail mounting\/wall mounting using mounting plate for K60 compact module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.181 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-2BQ44-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968381211,"sku":"3RK1207-2BQ44-0AA3","price":450.27,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-2bq44-0aa3.webp?v=1784372844"},{"product_id":"siemens-3rk1207-3cg00-2aa2-3rk1-motor-controller","title":"Siemens 3RK1207-3CG00-2AA2 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1207-3CG00-2AA2 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i SlimLine Compact module SC22.5, IP20, analog, 4AI-RTD spring-type terminals 4 x analog input Thermal resistance\/resistor Overall width 22.5 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1207-3CG00-2AA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 30 V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 24 V with AS-i Power24V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to EN 61346-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs safety-related\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply for sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing AS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal range at the analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt 100 standard and climate range \/ Ni 100 \/ resistance measurement 0 ... 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function input variable parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D resolution for analog inputs\/outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function smoothing parameterizable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor AS-Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor external auxiliary voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003escrew and snap-on mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1207-3CG00-2AA2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968446747,"sku":"3RK1207-3CG00-2AA2","price":355.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1207-3cg00-2aa2.webp?v=1784372851"},{"product_id":"siemens-3rk1308-0aa00-0cp0-3rk1-0-4a-3p-400v-motor-controller","title":"Siemens 3RK1308-0AA00-0CP0 3RK1 0.4A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0AA00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW \/ 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0AA00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 0,4 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.413 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0AA00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968512283,"sku":"3RK1308-0AA00-0CP0","price":271.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0aa00-0cp0.webp?v=1784372857"},{"product_id":"siemens-3rk1308-0ab00-0cp0-3rk1-1a-3p-400v-motor-controller","title":"Siemens 3RK1308-0AB00-0CP0 3RK1 1A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0AB00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 0.25 kW \/ 400 V; Adjustment range 0.3 .. 1 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0AB00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 1 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.412 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0AB00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968545051,"sku":"3RK1308-0AB00-0CP0","price":272.91,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ab00-0cp0.webp?v=1784372864"},{"product_id":"siemens-3rk1308-0ac00-0cp0-3rk1-3a-3p-400v-motor-controller","title":"Siemens 3RK1308-0AC00-0CP0 3RK1 3A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0AC00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW \/ 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0AC00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 3 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.412 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0AC00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968610587,"sku":"3RK1308-0AC00-0CP0","price":282.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ac00-0cp0.webp?v=1784372870"},{"product_id":"siemens-3rk1308-0ad00-0cp0-3rk1-9a-3p-400v-motor-controller","title":"Siemens 3RK1308-0AD00-0CP0 3RK1 9A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0AD00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 4 kW \/ 400 V; Adjustment range 2.8 .. 9 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0AD00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 9 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.412 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0AD00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968676123,"sku":"3RK1308-0AD00-0CP0","price":300.16,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ad00-0cp0.webp?v=1784372877"},{"product_id":"siemens-3rk1308-0ae00-0cp0-3rk1-12a-3p-400v-motor-controller","title":"Siemens 3RK1308-0AE00-0CP0 3RK1 12A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0AE00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Direct-on-line starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW \/ 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0AE00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 12 A: (8-0,5: 72-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0AE00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968741659,"sku":"3RK1308-0AE00-0CP0","price":391.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ae00-0cp0.webp?v=1784372883"},{"product_id":"siemens-3rk1308-0ba00-0cp0-3rk1-0-4a-3p-400v-motor-controller","title":"Siemens 3RK1308-0BA00-0CP0 3RK1 0.4A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0BA00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW \/ 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0BA00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 0,4 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0BA00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968807195,"sku":"3RK1308-0BA00-0CP0","price":435.31,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ba00-0cp0.webp?v=1784372890"},{"product_id":"siemens-3rk1308-0bb00-0cp0-3rk1-1a-3p-400v-motor-controller","title":"Siemens 3RK1308-0BB00-0CP0 3RK1 1A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0BB00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.25 kW \/ 400 V; Adjustment range 0.3 .. 1 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0BB00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 1 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.445 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0BB00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968839963,"sku":"3RK1308-0BB00-0CP0","price":438.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0bb00-0cp0.webp?v=1784372896"},{"product_id":"siemens-3rk1308-0bc00-0cp0-3rk1-3a-3p-400v-motor-controller","title":"Siemens 3RK1308-0BC00-0CP0 3RK1 3A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0BC00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Reversing starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW \/ 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0BC00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 3 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.448 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0BC00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968905499,"sku":"3RK1308-0BC00-0CP0","price":450.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0bc00-0cp0.webp?v=1784372903"},{"product_id":"siemens-3rk1308-0bd00-0cp0-3rk1-9a-3p-400v-motor-controller","title":"Siemens 3RK1308-0BD00-0CP0 3RK1 9A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0BD00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Reversing starter High Feature; Electronic switching; Electronic overload protection up to 4 kW \/ 400 V; Adjustment range 2.8 .. 9 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0BD00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 9 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.444 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0BD00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619968971035,"sku":"3RK1308-0BD00-0CP0","price":470.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0bd00-0cp0.webp?v=1784372910"},{"product_id":"siemens-3rk1308-0be00-0cp0-3rk1-12a-3p-400v-motor-controller","title":"Siemens 3RK1308-0BE00-0CP0 3RK1 12A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0BE00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Reversing starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW \/ 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0BE00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 12 A: (8-0,5: 72-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0BE00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969003803,"sku":"3RK1308-0BE00-0CP0","price":571.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0be00-0cp0.webp?v=1784372917"},{"product_id":"siemens-3rk1308-0ca00-0cp0-3rk1-0-4a-3p-400v-motor-controller","title":"Siemens 3RK1308-0CA00-0CP0 3RK1 0.4A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0CA00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW \/ 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0CA00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe direct-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 0,4 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.421 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0CA00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969036571,"sku":"3RK1308-0CA00-0CP0","price":440.54,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ca00-0cp0.webp?v=1784372923"},{"product_id":"siemens-3rk1308-0cb00-0cp0-3rk1-1a-3p-400v-motor-controller","title":"Siemens 3RK1308-0CB00-0CP0 3RK1 1A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0CB00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 0.25 kW \/ 400 V; Adjustment range 0.3 .. 1 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0CB00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe direct-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 1 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.425 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0CB00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969102107,"sku":"3RK1308-0CB00-0CP0","price":450.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0cb00-0cp0.webp?v=1784372930"},{"product_id":"siemens-3rk1308-0cc00-0cp0-3rk1-3a-3p-400v-motor-controller","title":"Siemens 3RK1308-0CC00-0CP0 3RK1 3A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0CC00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW \/ 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0CC00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe direct-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 3 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.427 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0CC00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969134875,"sku":"3RK1308-0CC00-0CP0","price":470.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0cc00-0cp0.webp?v=1784372937"},{"product_id":"siemens-3rk1308-0cd00-0cp0-3rk1-9a-3p-400v-motor-controller","title":"Siemens 3RK1308-0CD00-0CP0 3RK1 9A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0CD00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 4 kW \/ 400 V; Adjustment range 2.8 .. 9 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0CD00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe direct-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 9 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.425 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0CD00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969167643,"sku":"3RK1308-0CD00-0CP0","price":491.83,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0cd00-0cp0.webp?v=1784372945"},{"product_id":"siemens-3rk1308-0ce00-0cp0-3rk1-12a-3p-400v-motor-controller","title":"Siemens 3RK1308-0CE00-0CP0 3RK1 12A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0CE00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Fail-safe direct-on-line starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW \/ 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0CE00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe direct-on-line starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 12 A: (8-0,5: 72-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.436 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0CE00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969233179,"sku":"3RK1308-0CE00-0CP0","price":610.23,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0ce00-0cp0.webp?v=1784372951"},{"product_id":"siemens-3rk1308-0da00-0cp0-3rk1-0-4a-3p-400v-motor-controller","title":"Siemens 3RK1308-0DA00-0CP0 3RK1 0.4A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0DA00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Failsafe reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW \/ 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0DA00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe reversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 0,4 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.443 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0DA00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969265947,"sku":"3RK1308-0DA00-0CP0","price":579.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0da00-0cp0.webp?v=1784372958"},{"product_id":"siemens-3rk1308-0db00-0cp0-3rk1-1a-3p-400v-motor-controller","title":"Siemens 3RK1308-0DB00-0CP0 3RK1 1A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0DB00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Failsafe reversing starter High Feature; Electronic switching; Electronic overload protection up to 0.25 kW \/ 400 V; Adjustment range 0.3 .. 1 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0DB00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe reversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 1 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.452 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0DB00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969331483,"sku":"3RK1308-0DB00-0CP0","price":583.53,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0db00-0cp0.webp?v=1784372967"},{"product_id":"siemens-3rk1308-0dc00-0cp0-3rk1-3a-3p-400v-motor-controller","title":"Siemens 3RK1308-0DC00-0CP0 3RK1 3A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0DC00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Failsafe reversing starter High Feature; Electronic switching; electronic overload protection up to 1.1 kW \/ 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0DC00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe reversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 3 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.449 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0DC00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969364251,"sku":"3RK1308-0DC00-0CP0","price":607.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0dc00-0cp0.webp?v=1784372973"},{"product_id":"siemens-3rk1308-0dd00-0cp0-3rk1-9a-3p-400v-motor-controller","title":"Siemens 3RK1308-0DD00-0CP0 3RK1 9A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0DD00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Failsafe reversing starter High Feature; Electronic switching; Electronic overload protection up to 4 kW \/ 400 V; Adjustment range 2.8 .. 9 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0DD00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe reversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 9 A: (8-0,7: 70-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.453 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0DD00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969397019,"sku":"3RK1308-0DD00-0CP0","price":628.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0dd00-0cp0.webp?v=1784372981"},{"product_id":"siemens-3rk1308-0de00-0cp0-3rk1-12a-3p-400v-motor-controller","title":"Siemens 3RK1308-0DE00-0CP0 3RK1 12A 3P 400V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1308-0DE00-0CP0 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. Failsafe reversing starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW \/ 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI\/LC module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1308-0DE00-0CP0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment version according to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail-safe reversing starter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-site operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntrinsic device protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote firmware update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor power supply reverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC in hot operating state per pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween main and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed current maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm to 6 Hz; 2 g to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of coordination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60947-4-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-53a: 12 A: (8-0,5: 72-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.462 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1308-0DE00-0CP0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969462555,"sku":"3RK1308-0DE00-0CP0","price":733.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1308-0de00-0cp0.webp?v=1784372987"},{"product_id":"siemens-3rk1400-1dq00-0aa3-3rk1-2a-24v-motor-controller","title":"Siemens 3RK1400-1DQ00-0AA3 3RK1 2A 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1400-1DQ00-0AA3 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-i compact module K60 digital 4 DI\/4 DQ, IP67 4 x input, maximum 200 mA 4 x output, 2 A, 24 V DC maximal 4 A for all outputs 8 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1400-1DQ00-0AA3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edigital I\/O modules for operation in the field, IP67 - K60\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the device type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003estandard slave\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection of the inputs and outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply for sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing AS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt ambient temperature 40 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of connection technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2- and 3-wire technology\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of the input voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY-II assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage of output voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity of the semiconductor output at DC-13 at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of switching output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNP transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the pin assignment of the outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY-II assignement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProperty of the output short-circuit proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.191 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1400-1DQ00-0AA3 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969495323,"sku":"3RK1400-1DQ00-0AA3","price":283.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1400-1dq00-0aa3.webp?v=1784372993"},{"product_id":"siemens-3rk1405-2bg00-2aa2-3rk1-24v-motor-controller","title":"Siemens 3RK1405-2BG00-2AA2 3RK1 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1405-2BG00-2AA2 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. ASIsafe SlimLine Compact module SC17.5F digital safety 2 F-DI\/2 DQ, IP20 2 x input for mechanical sensors 2 x standard output 24 V DC Output supply can be switched spring-type terminals Width 17.5 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1405-2BG00-2AA2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 30 V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt 24 V with AS-i Power24V maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to EN 61346-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital inputs safety-related\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of input characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emechanical contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of switching output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNP transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProperty of the output short-circuit proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in induction protection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal current of digital outputs per module maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A with supply via AS interface \/ 0.5 A with supply via Uaux\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of voltage supply at the outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAS interface \/ U_AUX switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity of the semiconductor output at DC-13 at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A; 0.15 A with supply via AS interface \/ 0.5 A with supply via Uaux\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of analog outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePFHD with high demand rate according to IEC 62061\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5E-9 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level (PL) according to EN ISO 13849-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ee\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1405-2BG00-2AA2 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969528091,"sku":"3RK1405-2BG00-2AA2","price":238.29,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1405-2bg00-2aa2.webp?v=1784372999"},{"product_id":"siemens-3rk1901-0ca00-3rk1-24v-motor-controller","title":"Siemens 3RK1901-0CA00 3RK1 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1901-0CA00 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-Interface mounting plate K60 for compact modules K60 for wall mounting for 2 flat cables AS-i cable (yellow) and AS-i cable 24 V (black). Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1901-0CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003einsulation piercing method for AS-Interface flat cable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation or assembly note\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eadditional seals only required if the flat cables end in the module (3RK1 902-0AR00)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1901-0CA00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619969593627,"sku":"3RK1901-0CA00","price":22.04,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1901-0ca00.webp?v=1784373004"},{"product_id":"siemens-3rk1901-0cb01-3rk1-24v-motor-controller","title":"Siemens 3RK1901-0CB01 3RK1 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1901-0CB01 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-Interface mounting plate K60 for compact modules K60 for installation on standard mounting rail for 2 flat cables AS-i cable (yellow) and AS-i cable 24 V (black). Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1901-0CB01\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of electrical connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003einsulation piercing method for AS-Interface flat cable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation or assembly note\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eflat cable end in the module possible with additional seals (3RK1902-0AR00)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.091 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1901-0CB01 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619973198107,"sku":"3RK1901-0CB01","price":21.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1901-0cb01.webp?v=1784373010"},{"product_id":"siemens-3rk1901-1de12-1aa0-3rk1-4a-24v-motor-controller","title":"Siemens 3RK1901-1DE12-1AA0 3RK1 4A 24V Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1901-1DE12-1AA0 is a single data decoupling module from the SENTRON\/SIRIUS 3RK1 series. AS-i data decoupler 1 x 4 A Screw terminals, AS-i single Data decoupling module IP20, SlimLine S22.5 Screw terminals Overall width module 22.5 mm IN: 24 V \/ 30 V DC OUT: 1 x AS-i, 4 A Integrated overload protection Integrated ground fault detection Signaling contact Remote reset. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1901-1DE12-1AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle data decoupling module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlimLine S22.5 - Module to beused in the IP20 control cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation altitude at height above sea level maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003em\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuring storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity at 25 °C during operation maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied active power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-RESET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal reset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual RESET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround fault detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest function of signaling contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for grounded AS-i networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdapted for non-grounded AS-i networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for AS-i Power24V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential connected time-delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAS-Interface data decoupling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.186 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1901-1DE12-1AA0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619974181147,"sku":"3RK1901-1DE12-1AA0","price":163.49,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1901-1de12-1aa0.webp?v=1784373017"},{"product_id":"siemens-3rk1901-1ka00-3rk1-motor-controller","title":"Siemens 3RK1901-1KA00 3RK1 Motor Controller","description":"\u003cp\u003eThe Siemens 3RK1901-1KA00 is a motor controller from the SENTRON\/SIRIUS 3RK1 series. AS-Interface accessory Cover M12 for module IP67 outer diameter 15 mm, with O-ring. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1901-1KA00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RK1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor free M12 sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RK1901-1KA00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RK1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619976573211,"sku":"3RK1901-1KA00","price":5.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rk1901-1ka00.webp?v=1784373024"}],"url":"https:\/\/stoklink.com\/collections\/motor-controller.oembed?page=4","provider":"Stoklink","version":"1.0","type":"link"}