{"title":"Monitoring Relays (Phase, Voltage, Current, Level)","description":"\u003cp\u003eMonitoring relays from ABB, Siemens and Schneider Electric supervise phase sequence, phase loss, voltage, current, residual current and liquid level. The range includes CM and 3RS7 series, 3RQ4 and 3UG5 units and Harmony control relays, with measuring ranges up to about 10 A. Stoklink ships worldwide from Turkey and quotes project quantities on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase monitoring relays for phase sequence, phase loss and under or overvoltage, such as the ABB CM-PVS and CM-PVE types.\u003c\/li\u003e\n\u003cli\u003eSingle-phase voltage and current monitors, including ABB CM single-phase monitors and Harmony voltage control relays.\u003c\/li\u003e\n\u003cli\u003eLevel monitoring relays, for example conductive fill-level units with a resistance setting range.\u003c\/li\u003e\n\u003cli\u003eResidual current monitor relays for earth-leakage supervision.\u003c\/li\u003e\n\u003cli\u003eSiemens SIRIUS monitoring relays in the 3UG5, 3RS7 and 3RR2 series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMonitored quantity: phase, voltage, current, residual current or level.\u003c\/li\u003e\n\u003cli\u003eMeasuring range and set window: choose a range where your nominal value sits mid-scale.\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 24-240 V AC\/DC universal supply units cover most panels.\u003c\/li\u003e\n\u003cli\u003eOutput contacts: one or two C\/O contacts, and the switched current at 250 V.\u003c\/li\u003e\n\u003cli\u003eDelay and hysteresis: adjustable trip delay avoids nuisance trips on short dips.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does a phase monitoring relay protect against?\u003c\/h3\u003e\u003cp\u003eIt detects phase loss, wrong phase sequence and voltage outside the set window. Motors, pumps and compressors are protected from running on a faulty supply.\u003c\/p\u003e\u003ch3\u003eIs a monitoring relay the same as an overload relay?\u003c\/h3\u003e\u003cp\u003eNo. An overload relay protects a motor from thermal overload. A monitoring relay supervises the supply or process, and often works together with the overload device.\u003c\/p\u003e\u003ch3\u003eCan I order monitoring relays for export projects?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"abb-1svr560730r3401-cm-ufd-m31-voltage-monitoring-relay","title":"ABB 1SVR560730R3401 CM-UFD.M31 3C\/O Grid Feeding Voltage Monitoring Relay L-L 0-540V AC L-N 0-312V AC","description":"\u003cp\u003eThe ABB CM-UFD.M31 (SKU: 1SVR560730R3401) is a grid feeding voltage monitoring relay from the CM-UFD series, designed to monitor AC supply voltage in grid-connected photovoltaic and distributed energy systems. Offering a 3-changeover-contact output, a line-to-line measurement range of 0–540V AC and line-to-neutral range of 0–312V AC, the CM-UFD.M31 ensures compliant disconnection of grid-feeding inverters in accordance with German VDE-AR-N grid codes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-UFD.M31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR560730R3401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-UFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 C\/O (3 changeover contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range (L-L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–540V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range (L-N)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–312V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614492914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 mm × 90 mm × 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.304 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4105:\u003c\/strong\u003e German grid connection standard for low-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4110:\u003c\/strong\u003e German grid connection standard for medium-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE-AR-N 4120:\u003c\/strong\u003e German grid connection standard for high-voltage power generating systems — verified compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Verband der Elektrotechnik — German electrical safety and quality certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association — certified for use in North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU Regulation (EC) No 1907\/2006 — substances of very high concern compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive 2011\/65\/EU — compliant, hazardous substance restrictions met\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — product meets all applicable EU directives\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGrid-feeding photovoltaic (PV) inverter disconnection monitoring\u003c\/li\u003e\n\u003cli\u003eDistributed energy resource (DER) grid interface protection\u003c\/li\u003e\n\u003cli\u003eLow-, medium-, and high-voltage grid compliance monitoring per VDE-AR-N 4105 \/ 4110 \/ 4120\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial control panels requiring certified voltage supervision\u003c\/li\u003e\n\u003cli\u003eRenewable energy installations requiring automatic grid disconnection on voltage anomaly\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat is the CM-UFD.M31 used for?\u003c\/strong\u003e\u003cbr\u003eThe CM-UFD.M31 is a grid feeding monitoring relay used to supervise AC supply voltage in grid-connected systems. It detects voltage anomalies and triggers its 3 changeover contacts to disconnect grid-feeding inverters in compliance with VDE-AR-N grid codes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat voltage ranges does the CM-UFD.M31 support?\u003c\/strong\u003e\u003cbr\u003eIt monitors line-to-line (L-L) voltages from 0 to 540V AC and line-to-neutral (L-N) voltages from 0 to 312V AC, making it suitable for standard European three-phase systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich grid codes is the CM-UFD.M31 certified to?\u003c\/strong\u003e\u003cbr\u003eThe relay is certified to VDE-AR-N 4105 (low voltage), VDE-AR-N 4110 (medium voltage), and VDE-AR-N 4120 (high voltage), as well as holding CE, VDE, CSA, REACH, and RoHS certifications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229035794715,"sku":"1SVR560730R3401","price":1210.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr560730r3401-cm-ufd-m31-l-n-0-312v-ac_8634ed3e-8a7f-4fd6-a081-a1753946b704.webp?v=1777160764"},{"product_id":"abb-1svr730840r0200-cm-srs-11s-current-monitoring-relay","title":"ABB 1SVR730840R0200 CM-SRS.11S Current Monitoring Relay 1C\/O 3mA-1A RMS 24-240VAC\/DC Single-Phase","description":"\u003cp\u003eThe ABB CM-SRS.11S (SKU: 1SVR730840R0200) is a single-phase current monitoring relay designed for precise over- and under-current detection in industrial automation and control panel applications. Part of the ABB CM single-phase monitors series, the CM-SRS.11S monitors AC\/DC currents from 3 mA to 1 A RMS across a wide supply voltage range of 24–240 V AC\/DC, providing one changeover (1C\/O) output contact for reliable protection and signalling. Its compact 22.5 mm DIN rail housing makes it ideal for space-constrained control cabinets.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-SRS.11S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730840R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM single-phase monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 mA – 1 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1C\/O (1 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.145 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the UK market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL and CSA dual-certified for North American safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for evaluation of electrical and electronic equipment with respect to the restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOver-current and under-current monitoring in industrial machinery and control panels\u003c\/li\u003e\n\u003cli\u003eLoad monitoring for motors, pumps, fans, and conveyors\u003c\/li\u003e\n\u003cli\u003eWire-break and load-loss detection in process automation\u003c\/li\u003e\n\u003cli\u003eProtection of heating elements and resistive loads\u003c\/li\u003e\n\u003cli\u003eEnergy management and consumption monitoring systems\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat current range does the CM-SRS.11S monitor?\u003c\/h3\u003e\u003cp\u003eThe CM-SRS.11S monitors currents from 3 mA to 1 A RMS, making it suitable for a wide range of low-current monitoring applications in industrial and commercial control systems.\u003c\/p\u003e\u003ch3\u003eWhat supply voltages are compatible with the CM-SRS.11S?\u003c\/h3\u003e\u003cp\u003eThe relay accepts a universal supply voltage of 24–240 V AC\/DC, eliminating the need for separate power supplies in most standard control panel applications.\u003c\/p\u003e\u003ch3\u003eWhat output does the CM-SRS.11S provide?\u003c\/h3\u003e\u003cp\u003eThe CM-SRS.11S provides one changeover (1C\/O) output contact, enabling both normally open (NO) and normally closed (NC) circuit configurations for alarm or control functions.\u003c\/p\u003e\u003ch3\u003eWhat DIN rail width does the CM-SRS.11S occupy?\u003c\/h3\u003e\u003cp\u003eThe CM-SRS.11S fits a standard 22.5 mm DIN rail slot, consistent with IEC 60715 DIN rail mounting standards.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229333328155,"sku":"1SVR730840R0200","price":117.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730840r0200-cm-srs-11s-rms-24-240vac-dc-single-phase_4a89111e-bfdd-4d20-a7f8-40ccaeb1b0c3.webp?v=1777160872"},{"product_id":"abb-1svr730841r1200-cm-srs-11s-current-monitoring-relay","title":"ABB 1SVR730841R1200 CM-SRS.11S Current Monitoring Relay 1C\/O 3mA-1A RMS 220-240V AC Single-Phase","description":"\u003cp\u003eThe ABB CM-SRS.11S current monitoring relay (SKU: 1SVR730841R1200) is a single-phase current monitoring device designed to protect motors, pumps, and industrial loads from under-current and over-current faults. With a wide monitoring range of 3mA to 1A RMS and a rated supply voltage of 220–240V AC, the CM-SRS.11S delivers reliable protection in compact DIN-rail-mountable form — measuring just 22.5mm wide — making it ideal for space-constrained control panels in industrial automation and building services applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-SRS.11S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730841R1200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852326\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Monitoring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 mA – 1 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.161 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable EU directives for electrical equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to UL and CSA standards for the North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for Industrial Control Equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — generic immunity standard for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — generic emission standard for residential, commercial, and light-industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor under-current and over-current protection in pumping stations and HVAC systems\u003c\/li\u003e\n  \u003cli\u003eLoad monitoring and broken-belt or dry-run detection in conveyor and pump applications\u003c\/li\u003e\n  \u003cli\u003eProcess current monitoring in industrial automation and control panels\u003c\/li\u003e\n  \u003cli\u003eMachine protection in manufacturing and packaging lines\u003c\/li\u003e\n  \u003cli\u003eBuilding services electrical distribution boards requiring compact single-phase monitoring\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229333557531,"sku":"1SVR730841R1200","price":109.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730841r1200-cm-srs-11s-220-240v-ac-single-phase_bd418469-1095-44e5-82f9-36f9bcc46597.webp?v=1777160881"},{"product_id":"abb-1svr730841r1300-cm-srs-12s-current-monitoring-relay","title":"ABB 1SVR730841R1300 CM-SRS.12S Current Monitoring Relay 1C\/O 0.3-15A RMS 220-240V AC","description":"\u003cp\u003eThe ABB CM-SRS.12S (SKU: 1SVR730841R1300) is a single-phase current monitoring relay designed for industrial automation and control panel applications. It monitors AC RMS current in the range of 0.3–15A on a 220–240V AC supply, providing a 1 changeover (1C\/O) output contact to signal overcurrent or undercurrent conditions. Part of ABB's CM single-phase monitors series, the CM-SRS.12S delivers reliable, precise current supervision to protect motors, transformers, and other electrical loads in demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-SRS.12S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730841R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3–15 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (1 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm × 85.6 mm × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.168 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to both UL (USA) and CSA (Canada) safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment standard (Underwriters Laboratories)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association — Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334278427,"sku":"1SVR730841R1300","price":109.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730841r1300-cm-srs-12s-rms-220-240v-ac_808f7432-9747-45ee-96ad-1dfdff64da97.webp?v=1777160886"},{"product_id":"abb-1svr730840r0500-cm-srs-22s-current-monitoring-relay","title":"ABB 1SVR730840R0500 CM-SRS.22S 0.3-15A RMS 24-240V AC\/DC 2 C\/O Current Monitoring Relay","description":"\u003cp\u003eThe ABB CM-SRS.22S (SKU: 1SVR730840R0500) is a single-phase current monitoring relay designed to detect over-current and under-current conditions in industrial control systems. Part of ABB's CM single-phase monitors series, it supports a wide measurement range of 0.3–15 A RMS and a universal supply voltage of 24–240 V AC\/DC, making it highly versatile for global installation. With two changeover (2 c\/o) output contacts, the CM-SRS.22S provides reliable switching for alarm and protection circuits in automation and power distribution applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-SRS.22S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730840R0500\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3–15 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 c\/o (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 mm × 30 mm × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union CE marking requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to both Canadian and US safety standards (UL\/CSA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certification for global market acceptance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Certified by DNV GL for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed per UL 508 standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation and assessment for RoHS compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) generic standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European standard for measuring relays and protection equipment safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic emission and immunity standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for safety of industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOver-current and under-current monitoring in motor protection circuits\u003c\/li\u003e\n  \u003cli\u003eLoad monitoring in HVAC, pump, and compressor control panels\u003c\/li\u003e\n  \u003cli\u003eProcess fault detection in industrial automation and PLC-based systems\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore panel installations (DNV GL certified)\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting in low-voltage switchgear and distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334376731,"sku":"1SVR730840R0500","price":133.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730840r0500-cm-srs-22s-abb-1svr730840r0500-cm-srs-22s_424b4d58-8fc7-4e20-88ec-3e129601843b.webp?v=1777393983"},{"product_id":"abb-1svr730830r0300-cm-ess-1s-voltage-monitoring-relay","title":"ABB 1SVR730830R0300 CM-ESS.1S Voltage Monitoring Relay 1 C\/O 3-600V RMS 24-240V AC\/DC 4A Single-Phase","description":"\u003cp\u003eThe ABB CM-ESS.1S voltage monitoring relay (SKU: 1SVR730830R0300) is a single-phase monitoring device from ABB's CM series, designed to detect under-voltage, over-voltage, and supply failures across a wide measurement range of 3–600 V RMS. With a universal auxiliary supply of 24–240 V AC\/DC, a 1 C\/O (SPDT) output contact rated at 4 A, and a compact 22.5 mm DIN rail housing, the CM-ESS.1S suits a broad range of industrial control panel and power quality applications where reliable voltage supervision is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ESS.1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730830R0300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–600 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.135 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — required for products placed on the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to both UL (USA) and CSA (Canada) standards for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL Standard for Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certification for Canadian market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility — generic emission and immunity standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European harmonised standard for measuring relay product safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European harmonised EMC generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334540571,"sku":"1SVR730830R0300","price":105.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730830r0300-cm-ess-1s-ac-dc-4a-single-phase_c6285330-ca8a-426f-80a6-b089b5778d54.webp?v=1777160852"},{"product_id":"abb-1svr730831r1300-cm-ess-1s-voltage-monitoring-relay","title":"ABB 1SVR730831R1300 CM-ESS.1S Voltage Monitoring Relay 1C\/O 3-600V RMS 220-240V AC Single-Phase","description":"\u003cp\u003eThe ABB CM-ESS.1S (SKU: 1SVR730831R1300) is a single-phase voltage monitoring relay designed to protect electrical equipment by continuously supervising supply voltage levels across a wide measurement range of 3–600V RMS. Part of the ABB CM single-phase monitors series, the CM-ESS.1S features a 1 changeover (1C\/O) output contact, a rated control voltage of 220–240V AC, and a compact 30 mm wide DIN rail housing — making it ideal for integration into industrial control panels where reliable voltage supervision is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ESS.1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730831R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–600V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Control Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.186 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) — generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardized DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonized standard for RoHS technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European harmonized standard for measuring relay product safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standards compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment — UL certification for the US market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Industrial control equipment — Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL (USA) and CSA (Canada) listing mark\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — post-Brexit certification for the Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase mains voltage supervision in industrial control panels and machinery\u003c\/li\u003e\n\u003cli\u003eUnder-voltage and over-voltage protection for sensitive loads and motors\u003c\/li\u003e\n\u003cli\u003ePump and compressor protection against supply voltage faults\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC system voltage monitoring\u003c\/li\u003e\n\u003cli\u003eProcess industry equipment protection where supply quality is critical\u003c\/li\u003e\n\u003cli\u003eIntegration into safety circuits requiring relay output signalling on voltage fault conditions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334704411,"sku":"1SVR730831R1300","price":98.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730831r1300-cm-ess-1s-220-240v-ac-single-phase_ab015be8-6f13-48d5-bdbb-fa2560d1bac1.webp?v=1777160866"},{"product_id":"abb-1svr730840r0300-cm-srs-12s-current-monitoring-relay","title":"ABB 1SVR730840R0300 CM-SRS.12S Current Monitoring Relay 1C\/O 0.3-15A RMS 24-240VAC\/DC Single-Phase","description":"\u003cp\u003eThe ABB CM-SRS.12S (SKU: 1SVR730840R0300) is a single-phase current monitoring relay designed for industrial automation and control panel applications. Part of ABB's CM single-phase monitors series, the CM-SRS.12S monitors RMS current in the range of 0.3–15A and provides a 1 changeover (1C\/O) output contact, making it ideal for protecting motors, heaters, and other loads against overcurrent and undercurrent faults. It operates on a wide supply voltage of 24–240V AC\/DC, ensuring versatile integration across a broad range of industrial installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-SRS.12S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730840R0300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3–15 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm × 85.6 mm × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.137 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant with Great Britain market regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US (UL508) and Canadian (CSA C22.2 No.14) markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association certification for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Mechanical requirements for measuring relays and protection equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to restrictions on hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — generic immunity standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — generic emission standard for residential and commercial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardized mounting on DIN rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor protection against overcurrent and undercurrent conditions in industrial automation\u003c\/li\u003e\n\u003cli\u003eHeater and resistive load monitoring in control panels\u003c\/li\u003e\n\u003cli\u003ePump and fan protection to detect dry-run or overload faults\u003c\/li\u003e\n\u003cli\u003eConveyor and machinery protection in manufacturing environments\u003c\/li\u003e\n\u003cli\u003eProcess monitoring in building automation and HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334802715,"sku":"1SVR730840R0300","price":117.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730840r0300-cm-srs-12s-rms-24-240vac-dc-single-phase_44d32a50-8537-4c4d-8198-f95944ea664b.webp?v=1777160876"},{"product_id":"abb-1svr730784r2300-cm-pss-31s-phase-monitoring-relay","title":"ABB 1SVR730784R2300 CM-PSS.31S Three-Phase Monitoring Relay 2 C\/O 0.1-30s 3x380V AC Phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-PSS.31S (SKU: 1SVR730784R2300) is a three-phase monitoring relay designed to protect motors, transformers, and industrial loads against phase faults including phase failure, phase sequence errors, and phase asymmetry. Rated at 3×380V AC with a 2 C\/O output and an adjustable time delay of 0.1–30 seconds, the CM-PSS.31S provides reliable protection in demanding control panel environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PSS.31S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730784R2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3×380V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.157 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to both UL and CSA standards for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential\/light industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products regarding restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255 \/ EN 61000-6:\u003c\/strong\u003e European standards for measuring relays and EMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor protection against phase failure, incorrect phase sequence, and phase asymmetry\u003c\/li\u003e\n\u003cli\u003eProtection of three-phase loads in industrial automation control panels\u003c\/li\u003e\n\u003cli\u003ePump, compressor, and conveyor motor protection systems\u003c\/li\u003e\n\u003cli\u003eGenerator and transformer monitoring in power distribution\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC motor protection applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the CM-PSS.31S monitor?\u003c\/strong\u003e\u003cbr\u003eThe ABB CM-PSS.31S monitors three-phase AC supplies for phase failure, incorrect phase sequence, and phase asymmetry, triggering its 2 C\/O output contacts upon a fault condition.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the adjustable time delay range?\u003c\/strong\u003e\u003cbr\u003eThe time delay is adjustable from 0.1 to 30 seconds, allowing engineers to set appropriate response times to avoid nuisance tripping.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the CM-PSS.31S suitable for DIN rail mounting?\u003c\/strong\u003e\u003cbr\u003eYes. The CM-PSS.31S is compliant with IEC 60715 and is designed for standard 35 mm DIN rail installation inside control panels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat certifications does the CM-PSS.31S carry?\u003c\/strong\u003e\u003cbr\u003eThe relay holds CE, UKCA, cULus, UL 508, CCC, CSA, CAN\/CSA C22.2 No.14, RoHS, and REACH certifications, making it suitable for global deployment.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229334999323,"sku":"1SVR730784R2300","price":108.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730784r2300-cm-pss-31s-phase-monitoring-relay_6cd17764-2b52-4ab4-b590-65b3d1039871.webp?v=1777160831"},{"product_id":"abb-1svr550870r9400-cm-pve-phase-monitoring-relay","title":"ABB 1SVR550870R9400 CM-PVE Phase Monitoring Relay 1NO 185-265V AC L1 L2 L3-N","description":"\u003cp\u003eThe ABB CM-PVE (SKU: 1SVR550870R9400) is a phase monitoring relay designed to protect three-phase electrical systems by continuously supervising voltage across L1, L2, L3, and N. The CM-PVE operates on a rated voltage of 185–265 V AC and features a 1NO output contact, making it a compact, reliable solution for detecting phase loss, phase asymmetry, and under\/over-voltage conditions in industrial control panels and automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550870R9400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (1 normally open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185–265 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL1, L2, L3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 x 78 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.069 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment safety and EMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed to UL 508 standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e UL certification recognized for Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association certification for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2:\u003c\/strong\u003e CSA standard compliance for electrical products in Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for RoHS assessment of electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential and industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e Generic EMC standards for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePhase loss and phase failure detection in three-phase industrial power systems\u003c\/li\u003e\n\u003cli\u003eMotor protection in manufacturing plants, pumping stations, and HVAC systems\u003c\/li\u003e\n\u003cli\u003ePreventing equipment damage from unbalanced or missing phase voltages in control panels\u003c\/li\u003e\n\u003cli\u003eIntegration into building automation and industrial automation control systems\u003c\/li\u003e\n\u003cli\u003eSafeguarding three-phase loads in compressors, conveyors, and process machinery\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335064859,"sku":"1SVR550870R9400","price":61.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550870r9400-cm-pve-l1-l2-l3-n_7b028de0-179d-4d2a-a036-060cec76b758.webp?v=1777160750"},{"product_id":"abb-1svr730784r3300-cm-pss-41s-phase-monitoring-relay","title":"ABB 1SVR730784R3300 CM-PSS.41S Three-Phase Monitoring Relay 2 C\/O 0.1-30s 3×400V AC Phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-PSS.41S (SKU: 1SVR730784R3300) is a three-phase monitoring relay designed to protect industrial equipment from phase faults, offering reliable detection of phase failure, phase sequence errors, and phase asymmetry on 3×400V AC networks. Featuring two changeover output contacts and an adjustable time delay of 0.1 to 30 seconds, the CM-PSS.41S is engineered for demanding industrial automation and control panel applications where motor and load protection is critical.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PSS.41S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730784R3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3×400V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 – 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H×W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.157 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European low-voltage and EMC directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for the UK market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed under UL508 for industrial control equipment (US \u0026amp; Canada)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL508:\u003c\/strong\u003e Industrial Control Equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association — industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN63000:\u003c\/strong\u003e Technical documentation for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential\/industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU RoHS directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335163163,"sku":"1SVR730784R3300","price":122.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730784r3300-cm-pss-41s-phase-monitoring-relay_7f067c80-48a1-4afe-b094-e11700735988.webp?v=1777160837"},{"product_id":"abb-1svr550871r9500-cm-pve-phase-monitoring-relay","title":"ABB 1SVR550871R9500 CM-PVE Phase Monitoring Relay 1NO 320-460V AC 3-Phase","description":"\u003cp\u003eThe ABB CM-PVE (SKU: 1SVR550871R9500) is a 3-phase monitoring relay designed to protect electrical equipment against phase failures, phase asymmetry, and incorrect phase sequences. The CM-PVE monitors supply voltages in the range of 320–460 V AC and provides a 1NO (normally open) output contact, making it a reliable choice for motor protection and industrial control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550871R9500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320–460 V AC (L1, L2, L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (1 normally open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 x 78 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.066 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European directives for safety and market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for the UK market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL listing for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment standard (Canada)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for RoHS assessment of electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard aligned with IEC 63000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals (SVHC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB CM-PVE phase monitoring relay is widely used in industrial automation and motor protection applications where 3-phase power quality is critical. Typical installations include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProtection of 3-phase motors against phase loss, phase reversal, and asymmetry\u003c\/li\u003e\n\u003cli\u003eControl panel integration for manufacturing and process automation\u003c\/li\u003e\n\u003cli\u003eHVAC systems and pump stations requiring continuous phase supervision\u003c\/li\u003e\n\u003cli\u003eMachine tool and compressor protection circuits\u003c\/li\u003e\n\u003cli\u003eBuilding automation and industrial drive protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335261467,"sku":"1SVR550871R9500","price":61.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550871r9500-cm-pve-320-460v-ac-3-phase_fb087921-1f33-4aec-baf3-3f438b198ca3.webp?v=1777160754"},{"product_id":"abb-1svr730824r9300-cm-pfs-s-phase-monitoring-relay","title":"ABB 1SVR730824R9300 CM-PFS.S Three-Phase Monitoring Relay 2C\/O 200-500V AC 50\/60Hz Phase Sequence Failure Detection","description":"\u003cp\u003eThe ABB CM-PFS.S (SKU: 1SVR730824R9300) is a three-phase monitoring relay designed to detect phase sequence faults, phase failure, and asymmetry in industrial power systems operating at 200–500V AC, 50\/60Hz. Featuring a dual change-over (2C\/O) output contact rated at 4A, the CM-PFS.S from ABB's CM Series provides reliable protection for motors, pumps, compressors, and other three-phase loads in demanding control panel environments. Its compact 22.5mm DIN rail footprint makes it ideal for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PFS.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730824R9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-Phase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2C\/O (2 change-over)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–500 V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.127 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association industrial control equipment certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified for Canadian electrical safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for assessment of electrical and electronic products with respect to restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential and light industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335392539,"sku":"1SVR730824R9300","price":66.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730824r9300-cm-pfs-s-sequence-failure-detection_98ef3831-2c7b-4976-b200-5193ae44c474.webp?v=1777160846"},{"product_id":"abb-1svr550824r9100-cm-pfe-phase-monitoring-relay","title":"ABB 1SVR550824R9100 CM-PFE Phase Sequence Monitoring Relay 1C\/O 208-440V AC","description":"\u003cp\u003eThe ABB CM-PFE (SKU: 1SVR550824R9100) is a phase sequence monitoring relay designed to protect three-phase electrical systems from phase sequence faults and asymmetry. Operating across a rated voltage range of 208–440V AC on lines L1, L2, and L3, the CM-PFE provides a single changeover (1C\/O) output contact for reliable integration into control panels and industrial automation systems. Compact at just 22.5 × 78 × 78.5 mm and weighing 68 g, it suits DIN-rail mounting in space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PFE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550824R9100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Sequence Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–440V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1C\/O (1 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 × 78 × 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.068 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment (listed as UL508)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) — generic standards for emission and immunity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardized DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European harmonised measuring relays and protection equipment safety standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic emission and immunity standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of three-phase motors and pumps against incorrect phase sequence at start-up\u003c\/li\u003e\n  \u003cli\u003ePrevention of equipment damage caused by reversed phase rotation in industrial drives\u003c\/li\u003e\n  \u003cli\u003eIntegration into control panels, motor control centres (MCCs), and automation cabinets\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC systems requiring phase sequence supervision\u003c\/li\u003e\n  \u003cli\u003eFood \u0026amp; beverage, water treatment, and manufacturing plant electrical protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335458075,"sku":"1SVR550824R9100","price":63.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550824r9100-cm-pfe-1c-o-208-440v-ac_e7834670-1b8a-4348-bdd0-6376ea9b5461.webp?v=1777160740"},{"product_id":"abb-1svr730830r0400-cm-ess-2s-voltage-monitoring-relay","title":"ABB 1SVR730830R0400 CM-ESS.2S Voltage Monitoring Relay 2 C\/O 3-600V RMS 24-240VAC\/DC","description":"\u003cp\u003eThe ABB CM-ESS.2S (SKU: 1SVR730830R0400) is a single-phase voltage monitoring relay from the CM series, designed to continuously monitor AC or DC supply voltages across a wide measurement range of 3–600 V RMS. With dual changeover (2 C\/O) output contacts and a supply voltage range of 24–240 VAC\/DC, the CM-ESS.2S is engineered for reliable over- and under-voltage protection in demanding industrial control panel environments. Its compact 22.5 mm DIN rail profile makes it ideal for space-sensitive installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ESS.2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730830R0400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–600 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm × 85.6 mm × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.176 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852166\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for electrical and electronic products with respect to restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) — generic standards for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail standardised mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European standard for measuring relays and protection equipment safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL (USA) and CSA (Canada) safety listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOver-voltage and under-voltage protection in industrial control panels\u003c\/li\u003e\n\u003cli\u003ePower supply monitoring in automation and process control systems\u003c\/li\u003e\n\u003cli\u003eEquipment protection in HVAC, pumping, and compressor installations\u003c\/li\u003e\n\u003cli\u003eDIN rail integration in MCC (Motor Control Centres) and distribution boards\u003c\/li\u003e\n\u003cli\u003eWide-range voltage monitoring across AC and DC networks from 3 to 600 V RMS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335621915,"sku":"1SVR730830R0400","price":117.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730830r0400-cm-ess-2s-3-600v-rms-24-240vac-dc_d36e8562-65e9-4f0a-b794-78a495702903.webp?v=1777160857"},{"product_id":"abb-1svr550881r9400-cm-pbe-phase-monitoring-relay","title":"ABB 1SVR550881R9400 CM-PBE Phase Loss Monitoring Relay 1NO 220-240V AC Phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-PBE phase monitoring relay (SKU: 1SVR550881R9400) is a compact, DIN-rail-mounted phase loss monitoring relay designed to protect three-phase electrical systems against phase loss conditions across L1, L2, and L3 relative to neutral (220–240V AC). Featuring a 1NO output contact, the CM-PBE delivers reliable fault detection for motors, pumps, compressors, and industrial automation equipment, making it an essential component in control panels and motor protection circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550881R9400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase loss monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (1 normally open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC (L1, L2, L3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 x 78 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.066 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614350498\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union CE marking requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed per UL 508 standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL listing for safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Certified per Canadian Standards Association industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA certified for Canadian and North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Declaration of Conformity:\u003c\/strong\u003e Full EU DoC issued by ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Compliant with technical documentation requirements for RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility — generic emission and immunity standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standards for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Compliant with DIN rail mounting dimensions standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the UK market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase motor protection against phase loss in pumps, fans, and compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring phase integrity monitoring\u003c\/li\u003e\n\u003cli\u003eAutomation systems where phase loss could damage connected loads\u003c\/li\u003e\n\u003cli\u003eBuilding management and HVAC systems with three-phase supply\u003c\/li\u003e\n\u003cli\u003eManufacturing and process control environments requiring reliable phase monitoring relay protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335687451,"sku":"1SVR550881R9400","price":55.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550881r9400-cm-pbe-phase-monitoring-relay_7347b2d4-eab3-4a83-b922-cf4f87dd3ec9.webp?v=1777160759"},{"product_id":"abb-1svr730830r0500-cm-ess-ms-voltage-monitoring-relay","title":"ABB 1SVR730830R0500 CM-ESS.MS Voltage Monitoring Relay 2 C\/O 3-600V RMS 24-240VAC\/DC 4A","description":"\u003cp\u003eThe ABB CM-ESS.MS (SKU: 1SVR730830R0500) is a single-phase voltage monitoring relay designed for continuous supervision of AC and DC supply voltages across an exceptionally wide measurement range of 3–600 V RMS. Part of ABB's CM single-phase monitors series, this 2 C\/O (2 changeover contact) relay provides reliable over- and under-voltage protection in control panels and industrial automation systems, with a coil supply voltage of 24–240 V AC\/DC and a compact 22.5 mm DIN-rail footprint.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ESS.MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730830R0500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Single-Phase Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852173\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–600 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary \/ Coil Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (IEC 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 × 85.6 × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.176 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No. 14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for RoHS compliance assessment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Mechanical requirements for measuring relays and protection equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e EMC immunity for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e EMC emission standard for residential and light industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e DIN rail mounting dimensions for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255:\u003c\/strong\u003e Measuring relays and protection equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Dual USA and Canadian UL listing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOver-voltage and under-voltage protection in control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eMonitoring of single-phase AC supply lines from 3 V to 600 V RMS\u003c\/li\u003e\n\u003cli\u003eDC bus voltage supervision in industrial automation and drives\u003c\/li\u003e\n\u003cli\u003eMachine tool and process control cabinet protection\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC power quality monitoring\u003c\/li\u003e\n\u003cli\u003eProtection of sensitive industrial loads against supply voltage deviations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat is the measurement voltage range of the CM-ESS.MS?\u003c\/strong\u003e\u003cbr\u003eThe CM-ESS.MS monitors voltages from 3 V to 600 V RMS, covering a very wide range suitable for both low-voltage signal circuits and standard 230\/400 V mains supplies.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat supply voltage does the CM-ESS.MS require?\u003c\/strong\u003e\u003cbr\u003eThe relay operates on an auxiliary\/coil supply of 24–240 V AC or DC, making it highly flexible for international applications without the need for separate power supplies.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow wide is the CM-ESS.MS for panel design purposes?\u003c\/strong\u003e\u003cbr\u003eThe relay has a standard 22.5 mm width and mounts on a DIN rail per IEC 60715, compatible with industry-standard enclosures and busbar systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the CM-ESS.MS approved for North American markets?\u003c\/strong\u003e\u003cbr\u003eYes. The CM-ESS.MS carries cULus listing (UL 508) and CAN\/CSA C22.2 No. 14 certification, making it suitable for use in both the United States and Canada.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229335949595,"sku":"1SVR730830R0500","price":125.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730830r0500-cm-ess-ms-rms-24-240vac-dc-4a_ebeb0df3-cd88-44de-b0d5-8db5710be917.webp?v=1777160862"},{"product_id":"abb-1svr730794r3300-cm-pvs-41s-phase-monitoring-relay","title":"ABB 1SVR730794R3300 CM-PVS.41S Three-Phase Monitoring Relay 2 C\/O 300-500V AC 4A 0.1-30s Phase Sequence Voltage","description":"\u003cp\u003eThe ABB CM-PVS.41S (SKU: 1SVR730794R3300) is a three-phase monitoring relay designed to protect industrial equipment from phase faults including phase loss, phase sequence errors, and voltage asymmetry across a wide input range of 300–500 V AC. Part of ABB's CM series, the CM-PVS.41S features a dual changeover (2 C\/O) output contact, an adjustable time delay of 0.1 to 30 seconds, and a compact 30 mm wide housing suited for DIN rail installation in control panels and motor protection circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PVS.41S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730794R3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-Phase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 × 300–500 V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.164 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL\/CSA dual certification for US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for assessment of electrical and electronic products with respect to restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — generic immunity standard for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — generic emission standard for residential environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor protection against phase loss, phase sequence reversal, and voltage unbalance in three-phase systems\u003c\/li\u003e\n\u003cli\u003eProtection of pumps, compressors, and HVAC systems operating on 300–500 V AC three-phase networks\u003c\/li\u003e\n\u003cli\u003eIndustrial automation control panels requiring phase integrity monitoring\u003c\/li\u003e\n\u003cli\u003eBuilding management systems and critical infrastructure where phase faults must be detected and isolated rapidly\u003c\/li\u003e\n\u003cli\u003eOEM machine builders integrating compact DIN-rail-mountable protection relays into motor starter assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat faults does the CM-PVS.41S detect?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe CM-PVS.41S monitors three-phase supplies for phase loss, incorrect phase sequence, and voltage outside the rated 300–500 V AC window, triggering its 2 C\/O output contacts after the set time delay.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the adjustable time delay range?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe time delay is adjustable from 0.1 to 30 seconds, allowing coordination with downstream protective devices and preventing nuisance tripping during brief supply disturbances.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs the CM-PVS.41S suitable for DIN rail mounting?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. At 30 mm wide and compliant with IEC 60715, the CM-PVS.41S mounts directly onto standard 35 mm DIN rails.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhich markets is this relay approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe CM-PVS.41S carries CE, UKCA, cULus (UL 508 \/ CSA C22.2 No.14), and CCC certifications, making it suitable for European, UK, North American, and Chinese markets.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336047899,"sku":"1SVR730794R3300","price":116.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730794r3300-cm-pvs-41s-phase-sequence-voltage_a1497d99-6ec9-4c2f-af96-5fb9d88f8d8d.webp?v=1777160842"},{"product_id":"abb-1svr730885r3300-cm-mps-21s-phase-monitoring-relay","title":"ABB 1SVR730885R3300 CM-MPS.21S Three-Phase Monitoring Relay 2 C\/O 180-280V AC 0.1-30s Phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-MPS.21S (SKU: 1SVR730885R3300) is a three-phase monitoring relay from the CM-MPS series, designed to detect phase faults, phase asymmetry, and phase sequence errors in three-phase AC power systems rated 3×180–280V AC. Featuring two changeover (2 C\/O) output contacts and an adjustable time delay of 0.1 to 30 seconds, the CM-MPS.21S provides reliable protection for motors, pumps, and industrial machinery from damaging supply anomalies. With a compact 97 × 30 × 109 mm DIN rail mount profile, it fits easily into standard control panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MPS.21S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730885R3300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MPS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3×180–280 V AC (L1-L2-L3-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.171 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851893\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union low voltage and EMC directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the United Kingdom market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed to both UL and CSA standards for USA and Canada (UL 508)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standards for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Certified for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential\/light-industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products regarding RoHS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255:\u003c\/strong\u003e Measuring relays and protection equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility generic standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection against phase loss, phase asymmetry, and incorrect phase sequence\u003c\/li\u003e\n  \u003cli\u003eProtection of pumps, compressors, and HVAC equipment in industrial installations\u003c\/li\u003e\n  \u003cli\u003eControl panel integration for three-phase power quality monitoring\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore electrical systems (DNV GL certified)\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and industrial process control panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336113435,"sku":"1SVR730885R3300","price":118.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730885r3300-cm-mps-21s-abb-1svr730885r3300-cm-mps-21s_9b1bcd60-85b5-45a1-b6b4-4d2c3e4c6bac.webp?v=1777393987"},{"product_id":"abb-1svr730794r1300-cm-pvs-31s-three-phase-monitoring-relay","title":"ABB 1SVR730794R1300 CM-PVS.31S 3-Phase Monitoring Relay 2 C\/O 160-300V AC 4A 0.1-30s Three-phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-PVS.31S three-phase monitoring relay (SKU: 1SVR730794R1300) is a compact, DIN-rail mounted relay designed to monitor three-phase supply voltages across all three lines (L1–L2–L3) in the range of 160–300V AC. Offering 2 changeover output contacts, an adjustable time delay of 0.1–30 seconds, and a rated current of 4A, the CM-PVS.31S provides reliable protection against phase loss, phase sequence errors, and voltage deviations in industrial control panels and automation systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PVS.31S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730794R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (L1–L2–L3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160–300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — compliant for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Certified by UL for both US (UL) and Canadian (CSA) markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment standard (UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association — Industrial Control Equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for assessment of electrical and electronic products with respect to restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential, commercial, and light-industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of three-phase motors and equipment against phase loss and phase sequence faults\u003c\/li\u003e\n  \u003cli\u003eMonitoring of three-phase supply voltage levels in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eAutomation systems requiring reliable phase monitoring and fault signalling\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and HVAC systems with three-phase power supplies\u003c\/li\u003e\n  \u003cli\u003ePump and compressor protection in process industries\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336178971,"sku":"1SVR730794R1300","price":126.82,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730794r1300-cm-pvs-31s-abb-1svr730794r1300-cm-pvs-31s_13a4de36-0a4a-454e-9a97-a7650e1dc56a.webp?v=1777393991"},{"product_id":"abb-1svr730774r1300-cm-pas-31s-phase-monitoring-relay","title":"ABB 1SVR730774R1300 CM-PAS.31S Three-Phase Monitoring Relay 2 C\/O 160-300V AC 0.1-30s Phase Monitoring Relay","description":"\u003cp\u003eThe ABB CM-PAS.31S (SKU: 1SVR730774R1300) is a three-phase monitoring relay designed to protect industrial electrical systems from phase faults including phase loss, phase sequence errors, and phase asymmetry across a supply voltage range of 160–300 V AC. Featuring 2 changeover (C\/O) output contacts and an adjustable time delay of 0.1 to 30 seconds, the CM-PAS.31S provides flexible and reliable protection for motors, drives, and control panel applications in industrial automation environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-PAS.31S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730774R1300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 160–300 V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 x 30 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.158 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — required for the Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA \/ CAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association industrial control equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential, commercial, and light-industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336277275,"sku":"1SVR730774R1300","price":116.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730774r1300-cm-pas-31s-phase-monitoring-relay_2ed076c0-edd1-4bb3-b717-5ce5f50e3b9a.webp?v=1777160827"},{"product_id":"abb-1svr730884r3300-cm-mps-41s-phase-monitoring-relay","title":"ABB 1SVR730884R3300 CM-MPS.41S Three-Phase Monitoring Relay 2C\/O 300-500V AC 0.1-30s Phase Sequence Failure Protection","description":"\u003cp\u003eThe ABB CM-MPS.41S (SKU: 1SVR730884R3300) is a three-phase monitoring relay designed to protect motors, machinery, and control panels against phase sequence errors, phase failure, and asymmetry in three-phase power systems rated 300–500V AC. Part of ABB's trusted CM-MPS series, the CM-MPS.41S features a dual change-over (2C\/O) output relay and an adjustable time delay of 0.1 to 30 seconds, making it ideal for demanding industrial automation environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MPS.41S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730884R3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-Phase Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 × 300–500 V AC (L1-L2-L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1–30 s (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779851862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for RoHS compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment mechanical requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions for DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonized standard for RoHS technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European standard for measuring relays mechanical requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment (UL Listed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Industrial control equipment (CSA certified)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL and CSA approval for US and Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor protection against phase loss, phase sequence reversal, and voltage asymmetry\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels monitoring three-phase supply integrity\u003c\/li\u003e\n\u003cli\u003eHVAC systems and pump stations requiring phase supervision\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power distribution (DNV GL approved)\u003c\/li\u003e\n\u003cli\u003eManufacturing automation lines with critical three-phase machinery\u003c\/li\u003e\n\u003cli\u003eBuilding management systems protecting compressors and large HVAC units\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat voltage range does the CM-MPS.41S monitor?\u003c\/strong\u003e\u003cbr\u003eThe CM-MPS.41S monitors three-phase supplies from 300 to 500V AC across phases L1, L2, and L3.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the 2C\/O output mean?\u003c\/strong\u003e\u003cbr\u003e2C\/O means two changeover relay outputs — each output has a normally open (NO) and normally closed (NC) contact, providing flexible wiring options for fault signalling or machine shutdown.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the CM-MPS.41S approved for marine applications?\u003c\/strong\u003e\u003cbr\u003eYes. The CM-MPS.41S carries DNV GL approval, making it suitable for marine and offshore installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the time delay be adjusted?\u003c\/strong\u003e\u003cbr\u003eYes. The response time delay is fully adjustable between 0.1 and 30 seconds, allowing engineers to tune trip response to suit their application.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336703259,"sku":"1SVR730884R3300","price":125.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730884r3300-cm-mps-41s-sequence-failure-protection_02fa4e65-b512-4c50-8fbf-60e4b6e87598.webp?v=1777160897"},{"product_id":"abb-1svr730740r0200-cm-tcs-12s-temperature-monitoring-relay","title":"ABB 1SVR730740R0200 CM-TCS.12S 0–100°C 24-240VAC\/DC 4A Temperature Monitoring Relay","description":"\u003cp\u003eThe ABB CM-TCS.12S (SKU: 1SVR730740R0200) is a temperature monitoring relay from the ABB CM temperature monitors series, designed to continuously monitor temperatures in the range of 0 to +100°C using a 24–240V AC\/DC supply voltage. The CM-TCS.12S provides reliable overshoot and undershoot protection for motors, transformers, and process equipment in industrial automation and control panel applications, offering a compact 97 × 30 × 109 mm DIN-rail mountable footprint.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-TCS.12S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730740R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Temperature Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 … +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.176 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852722\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by UL for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements (UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Det Norske Veritas — maritime and offshore industry type approval\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No. 60947-5-1:\u003c\/strong\u003e Canadian standard for low-voltage switchgear control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e International\/European standard for low-voltage control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-26:\u003c\/strong\u003e Measuring relays and protection equipment — electromagnetic compatibility requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardized mounting on DIN rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255:\u003c\/strong\u003e European standard series for measuring relays and protection equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC standard series for generic emission and immunity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for low-voltage switchgear control circuit devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe CM-TCS.12S temperature monitoring relay is widely deployed across industrial automation and process control applications where thermal protection is critical. Typical use cases include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor winding temperature monitoring to prevent thermal overload damage\u003c\/li\u003e\n  \u003cli\u003eTransformer and power supply thermal protection in control panels\u003c\/li\u003e\n  \u003cli\u003eHVAC and refrigeration system temperature supervision\u003c\/li\u003e\n  \u003cli\u003eIndustrial process equipment temperature control and alarming\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore applications (DNV GL approved)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229336867099,"sku":"1SVR730740R0200","price":152.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730740r0200-cm-tcs-12s-abb-1svr730740r0200-cm-tcs-12s_8c68cc8a-596b-4ed0-8a8f-4770660fb437.webp?v=1777393995"},{"product_id":"abb-1svr730850r0200-cm-ens-21s-level-monitoring-relay","title":"ABB 1SVR730850R0200 CM-ENS.21S 1C\/O 0.1-1000kΩ 4A 250V (Fill)Level Monitoring Relay","description":"\u003cp\u003eThe ABB CM-ENS.21S (SKU: 1SVR730850R0200) is a liquid (fill)level monitoring relay featuring a single changeover output contact and an adjustable sensitivity range of 0.1 to 1000 kΩ, making it suitable for detecting the presence or absence of conductive liquids across a wide range of industrial applications. Rated at 4 A and 250 V, the CM-ENS.21S mounts on standard DIN rail and integrates seamlessly into control panel assemblies requiring reliable level detection and process protection.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ENS.21S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730850R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(Fill)level monitoring relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 – 1000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614502927\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) — generic standards for emission and immunity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European standard for measuring relays and protection equipment safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (North America)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU Regulation (EC) No 1907\/2006 on chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eLiquid level detection in tanks, reservoirs, and process vessels\u003c\/li\u003e\n  \u003cli\u003ePump protection against dry-run or overflow conditions\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment plant automation\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing level control\u003c\/li\u003e\n  \u003cli\u003eHVAC and building services water management\u003c\/li\u003e\n  \u003cli\u003eMachine tool coolant level monitoring\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229337784603,"sku":"1SVR730850R0200","price":64.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730850r0200-cm-ens-21s-abb-1svr730850r0200-cm-ens-21s_588a6a23-699d-460e-978a-cd54bf9bb93c.webp?v=1777394004"},{"product_id":"abb-1svr550851r9500-cm-ene-min-level-relay","title":"ABB 1SVR550851R9500 CM-ENE MIN 1NO 220-240V AC (Fill)Level Monitoring Relay","description":"\u003cp\u003eThe ABB CM-ENE MIN (1SVR550851R9500) is a liquid fill-level monitoring relay from the ABB CM series, designed to detect minimum liquid levels in tanks, reservoirs, and industrial process vessels. Equipped with a 1NO (normally open) output contact and rated for 220–240V AC supply, the CM-ENE MIN provides reliable level detection for use in control panels and automation systems requiring precise fluid-level monitoring.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ENE MIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550851R9500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(Fill)Level Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (normally open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 x 78 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.106 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical equipment safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for products placed on the Great Britain market.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed to UL 508 standard for industrial control equipment (USA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL recognition for industrial control equipment, meeting CSA requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements for electrical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for electrical products sold in the Chinese market.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted harmful materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMinimum liquid level detection in water tanks, storage vessels, and process reservoirs\u003c\/li\u003e\n\u003cli\u003ePump protection against dry running by monitoring minimum fill levels\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and control panel integration for fluid management systems\u003c\/li\u003e\n\u003cli\u003eBuilding services, HVAC, and water treatment plant level monitoring\u003c\/li\u003e\n\u003cli\u003eMachine building applications requiring reliable conductive level sensing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat does the CM-ENE MIN monitor?\u003c\/h3\u003e\u003cp\u003eThe CM-ENE MIN monitors the minimum liquid level in a tank or vessel using conductive level sensing. When the liquid drops below the set electrode level, the relay output changes state to trigger an alarm or control action.\u003c\/p\u003e\u003ch3\u003eWhat is the supply voltage for the CM-ENE MIN?\u003c\/h3\u003e\u003cp\u003eThe ABB CM-ENE MIN relay operates on a 220–240V AC supply voltage.\u003c\/p\u003e\u003ch3\u003eHow many output contacts does the CM-ENE MIN provide?\u003c\/h3\u003e\u003cp\u003eThe CM-ENE MIN provides one normally open (1NO) output contact for integration into your control circuit.\u003c\/p\u003e\u003ch3\u003eWhat is the mounting width of the CM-ENE MIN?\u003c\/h3\u003e\u003cp\u003eThe CM-ENE MIN has a width of 22.5 mm, making it suitable for space-efficient DIN rail installation in control panels.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229337948443,"sku":"1SVR550851R9500","price":44.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550851r9500-cm-ene-min-fill-level-monitoring-relay_5cf3730e-376f-4a22-b4a7-d455d4257a18.webp?v=1777160745"},{"product_id":"abb-1svr730850r2100-cm-ens-13s-level-monitoring-relay","title":"ABB 1SVR730850R2100 CM-ENS.13S Liquid Level (Fill) Monitoring Relay 1 C\/O 5-100 kΩ Sensitivity 110-240V AC","description":"\u003cp\u003eThe ABB CM-ENS.13S liquid level monitoring relay (SKU: 1SVR730850R2100) is a compact, single-output (1 C\/O) fill-level monitoring relay designed for detecting the presence or absence of conductive liquids in industrial tanks and vessels. With an adjustable sensitivity range of 5–100 kΩ and a supply voltage of 110–240 V AC, the CM-ENS.13S provides reliable, cost-effective level control in demanding automation and process environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ENS.13S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730850R2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(Fill) Level Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (1 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–130 V AC \/ 220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 mm × 30 mm × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.177 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614502903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Approved for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN60255-27:\u003c\/strong\u003e Measuring relays and protection equipment – product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN61000-6:\u003c\/strong\u003e Electromagnetic compatibility (EMC) – generic standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear – standardized DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN63000:\u003c\/strong\u003e European harmonized standard for electrical\/electronic equipment documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN60255-27:\u003c\/strong\u003e Measuring relays and protection equipment – European product safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN61000-6:\u003c\/strong\u003e EMC generic standards – European harmonized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL508:\u003c\/strong\u003e Industrial control equipment – UL Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment – Canadian standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on chemicals (REACH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed for both US and Canadian markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed – valid for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338145051,"sku":"1SVR730850R2100","price":62.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730850r2100-cm-ens-13s-sensitivity-110-240v-ac_d570c083-cd7a-4274-8b04-00791003fa19.webp?v=1777160891"},{"product_id":"abb-1svr730850r0300-cm-ens-31s-level-monitoring-relay","title":"ABB 1SVR730850R0300 CM-ENS.31S 2C\/O 0.1-1000kΩ 250V 4A (Fill)Level Monitoring Relay","description":"\u003cp\u003eThe ABB CM-ENS.31S (SKU 1SVR730850R0300) is a liquid level monitoring relay designed for reliable fill-level detection in industrial automation and process control applications. Featuring two changeover (2C\/O) output contacts, an adjustable sensitivity range of 0.1 to 1000 kΩ, and a rated voltage of 250 V at 4 A, the CM-ENS.31S delivers accurate, dependable level monitoring for conductive liquids across a wide range of installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ENS.31S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730850R0300\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(Fill)Level Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 – 1000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.168 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614502910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed by Underwriters Laboratories for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Mechanical requirements for measuring relays and protection equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-2:\u003c\/strong\u003e Electromagnetic compatibility — immunity for industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6-3:\u003c\/strong\u003e Electromagnetic compatibility — emission standard for residential\/industrial environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60255 \/ EN 61000-6:\u003c\/strong\u003e Measuring relays and protection equipment; EMC standards family\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eLiquid level detection in tanks, reservoirs, and sumps for conductive media\u003c\/li\u003e\n  \u003cli\u003ePump protection — automatic start\/stop based on fill level thresholds\u003c\/li\u003e\n  \u003cli\u003eOverflow and dry-run prevention in water treatment and HVAC systems\u003c\/li\u003e\n  \u003cli\u003eProcess automation in food \u0026amp; beverage, chemical, and pharmaceutical plants\u003c\/li\u003e\n  \u003cli\u003eBuilding management systems requiring reliable level monitoring with relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338276123,"sku":"1SVR730850R0300","price":101.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730850r0300-cm-ens-31s-abb-1svr730850r0300-cm-ens-31s_34512021-7926-442a-86b5-f83b1eaa31d8.webp?v=1777393999"},{"product_id":"abb-1svr730700r2200-cm-mss-23s-ptc-relay","title":"ABB 1SVR730700R2200 CM-MSS.23S Thermistor Motor Protection Relay 2 C\/O 110-130V \/ 220-240V AC PTC","description":"\u003cp\u003eThe ABB CM-MSS.23S (SKU: 1SVR730700R2200) is a thermistor-based motor protection relay designed to safeguard electric motors against overtemperature by continuously monitoring PTC thermistor resistance embedded in motor windings. Part of the trusted CM-MSS series, the CM-MSS.23S provides a 2 change-over (2 C\/O) output contact configuration and accepts a wide supply voltage range of 110–130 V AC or 220–240 V AC, making it suitable for global industrial installations and control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS.23S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730700R2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay for Thermistor Protection (PTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 change-over)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–130 V AC \/ 220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTC Thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.197 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614496691\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformity with European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market regulations post-Brexit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Certified to both Canadian (cUL) and US (UL) safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Marine and offshore type approval by DNV GL classification society\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for electrical and electronic equipment (RoHS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-8:\u003c\/strong\u003e Control units for built-in thermal protection of rotating electrical machines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment per CSA Group standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvertemperature protection of AC and DC motors via embedded PTC thermistors\u003c\/li\u003e\n\u003cli\u003eMotor protection in industrial automation and control panel environments\u003c\/li\u003e\n\u003cli\u003eMarine and offshore motor protection (DNV GL approved)\u003c\/li\u003e\n\u003cli\u003eHVAC fan and pump motor protection in building automation systems\u003c\/li\u003e\n\u003cli\u003eCompressor and conveyor drive motor protection in manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338407195,"sku":"1SVR730700R2200","price":58.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730700r2200-cm-mss-23s-220-240v-ac-ptc_37aa2b8e-8800-4d09-baf5-c21a36ea071c.webp?v=1777160812"},{"product_id":"abb-1svr730712r1200-cm-mss-41s-ptc-relay","title":"ABB 1SVR730712R1200 CM-MSS.41S Thermistor Motor Protection Relay 2 C\/O 24-240V AC\/DC PTC Relay","description":"\u003cp\u003eThe ABB CM-MSS.41S (SKU: 1SVR730712R1200) is a relay for thermistor protection (PTC) designed to safeguard electric motors from overtemperature damage in industrial automation and control panel applications. Part of the CM-MSS series, the CM-MSS.41S features a 2 C\/O (DPDT) output contact configuration and accepts a wide supply voltage range of 24–240V AC\/DC, making it highly versatile for global installations. Weighing just 167 g and measuring 97 × 30 × 109 mm, it is engineered for compact DIN-rail mounting in demanding environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS.41S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730712R1200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614496677\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay for thermistor protection (PTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (DPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.167 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX (Directive 94\/9\/EC):\u003c\/strong\u003e Approved for use in explosive atmospheres per European ATEX directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — meets Great Britain market requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Certified for marine and offshore applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Canadian Standards Association industrial control equipment standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 50495:\u003c\/strong\u003e Safety devices for explosion protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for RoHS compliance assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60079-7:\u003c\/strong\u003e Explosion-proof increased safety equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear — control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-8:\u003c\/strong\u003e Control units for built-in thermal protection (PTC) of rotating electrical machines\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment — UL standard for safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e DIN rail mounting dimensions for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60079:\u003c\/strong\u003e Electrical apparatus for explosive gas atmospheres\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5 \/ EN 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA C22.2 \/ CSA:\u003c\/strong\u003e Canadian Standards Association product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemical substances compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Dual US and Canadian UL safety certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor overtemperature protection using PTC thermistor sensors embedded in motor windings\u003c\/li\u003e\n  \u003cli\u003eProtection of pumps, compressors, fans, and conveyors in industrial automation\u003c\/li\u003e\n  \u003cli\u003eSafe integration into ATEX-rated and potentially explosive environments\u003c\/li\u003e\n  \u003cli\u003eMarine and offshore motor protection systems (DNV GL certified)\u003c\/li\u003e\n  \u003cli\u003eControl panels requiring compact DIN-rail mounted protection relays\u003c\/li\u003e\n  \u003cli\u003eMulti-voltage installations across global facilities (24–240V AC\/DC universally)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338603803,"sku":"1SVR730712R1200","price":102.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730712r1200-cm-mss-41s-ac-dc-ptc-relay_9566caf8-b718-45a1-95cc-cd8885502990.webp?v=1777160818"},{"product_id":"abb-1svr730850r2200-cm-ens-23s-level-monitoring-relay","title":"ABB 1SVR730850R2200 CM-ENS.23S 1CO 0.1-1000kOhm 110-240V AC (Fill)Level Monitoring Relay","description":"\u003cp\u003eThe ABB CM-ENS.23S (SKU: 1SVR730850R2200) is a liquid level monitoring relay from the ABB CM Series, designed to detect and control fill levels in tanks and vessels using electrode-based conductivity sensing. With an adjustable sensitivity range of 0.1 to 1000 kOhm and a single changeover (1C\/O) output contact, the CM-ENS.23S provides reliable, interference-resistant level detection for industrial automation and process control applications operating at 110–130 V AC or 220–240 V AC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-ENS.23S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730850R2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614502897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(Fill)Level Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 – 1000 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–130 V AC \/ 220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.179 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to restrictions on hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60255-27:\u003c\/strong\u003e Measuring relays and protection equipment — product safety requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61000-6:\u003c\/strong\u003e Electromagnetic compatibility — generic emission and immunity standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60255-27:\u003c\/strong\u003e European standard for measuring relay and protection equipment safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61000-6:\u003c\/strong\u003e European EMC generic standards for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (North America)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14:\u003c\/strong\u003e Canadian standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLiquid level detection and control in industrial tanks and reservoirs\u003c\/li\u003e\n\u003cli\u003ePump control systems — automatic fill and drain cycles\u003c\/li\u003e\n\u003cli\u003eOverflow and dry-run protection for pumps and vessels\u003c\/li\u003e\n\u003cli\u003eWater treatment and wastewater management systems\u003c\/li\u003e\n\u003cli\u003eFood and beverage processing where conductive liquid monitoring is required\u003c\/li\u003e\n\u003cli\u003eHVAC condensate and coolant level monitoring\u003c\/li\u003e\n\u003cli\u003eControl panel integration on standard 35 mm DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338669339,"sku":"1SVR730850R2200","price":64.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730850r2200-cm-ens-23s-abb-1svr730850r2200-cm-ens-23s_4245c2b6-66cc-4ed2-928a-89693552b0a7.webp?v=1777394008"},{"product_id":"abb-1svr730712r2200-cm-mss-33s-ptc-motor-protection-relay","title":"ABB 1SVR730712R2200 CM-MSS.33S Thermistor Motor Protection Relay 2C\/O 110-130V\/220-240VAC PTC Relay","description":"\u003cp\u003eThe ABB CM-MSS.33S (SKU: 1SVR730712R2200) is a thermistor (PTC) motor protection relay from the CM-MSS series, designed to safeguard electric motors against overtemperature damage by monitoring embedded PTC thermistor sensors. The CM-MSS.33S features a dual changeover (2C\/O) output contact configuration and accepts a wide supply voltage range of 110–130V AC and 220–240V AC, making it suitable for diverse international control panel applications. With global certifications including ATEX, CE, UKCA, cULus, CCC, and DNV GL, this relay is engineered for demanding industrial and hazardous area environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS.33S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730712R2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay for thermistor protection (PTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–130V AC \/ 220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTC thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 × 30 × 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.199 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614496646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX (Directive 94\/9\/EC):\u003c\/strong\u003e Approved for use in explosive atmospheres and hazardous area installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e Meets United Kingdom Conformity Assessed requirements for the UK market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus (UL 508):\u003c\/strong\u003e Listed to UL 508 industrial control equipment standard for North American markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB:\u003c\/strong\u003e International CB Scheme certification for global market access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV GL:\u003c\/strong\u003e Certified for marine and offshore applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No. 14:\u003c\/strong\u003e Canadian Standards Association approval for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 50495:\u003c\/strong\u003e Safety devices for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for assessment of electrical and electronic products regarding restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60079-7:\u003c\/strong\u003e Explosive atmospheres — equipment protection by increased safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-8:\u003c\/strong\u003e Control units for built-in thermal protection (PTC) for rotating electrical machines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardized mounting on rails\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 \/ CSA:\u003c\/strong\u003e Canadian Standards Association certified for industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor overtemperature protection in industrial drives and automation systems\u003c\/li\u003e\n\u003cli\u003eHazardous area motor protection where ATEX compliance is mandatory\u003c\/li\u003e\n\u003cli\u003eMarine and offshore motor control panels (DNV GL certified)\u003c\/li\u003e\n\u003cli\u003eControl cabinet integration for motors equipped with embedded PTC thermistor sensors\u003c\/li\u003e\n\u003cli\u003eInternational installations requiring multi-voltage supply compatibility (110–130V \/ 220–240V AC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338800411,"sku":"1SVR730712R2200","price":62.18,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730712r2200-cm-mss-33s-110-130v-220-240vac-ptc-relay_0baa8a06-5d25-4124-9a26-b50244e949dc.webp?v=1777160822"},{"product_id":"abb-1svr550801r9300-cm-mse-thermistor-motor-protection-relay","title":"ABB 1SVR550801R9300 CM-MSE Thermistor Motor Protection Relay 1NO 220-240V AC PTC Relay","description":"\u003cp\u003eThe ABB CM-MSE (SKU: 1SVR550801R9300) is a thermistor motor protection relay designed to safeguard electric motors from overheating by monitoring PTC thermistor signals embedded in motor windings. Featuring a single normally-open (1NO) output contact and a rated supply voltage of 220–240V AC, the CM-MSE provides reliable thermal protection in control panels and industrial automation systems. Its compact 22.5 mm width makes it ideal for DIN rail installation in space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550801R9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay for Thermistor Protection (PTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (1 Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 x 78 x 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.104 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348785\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed to UL standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL certification for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor winding temperature monitoring via embedded PTC thermistors\u003c\/li\u003e\n\u003cli\u003eThermal overload protection for AC motors in industrial drive systems\u003c\/li\u003e\n\u003cli\u003eControl panel integration for motor starters and soft starters\u003c\/li\u003e\n\u003cli\u003eProtection of pumps, fans, compressors, and conveyor drives\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control environments\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat type of sensor does the CM-MSE work with?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe CM-MSE is designed to work with PTC (Positive Temperature Coefficient) thermistors embedded in motor windings, providing accurate and responsive thermal protection.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the output configuration of the CM-MSE relay?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe CM-MSE features one normally-open (1NO) output contact, which opens when the thermistor detects an over-temperature condition, triggering a motor shutdown signal.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs the CM-MSE suitable for DIN rail mounting?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. At only 22.5 mm wide, the CM-MSE is designed for standard DIN rail installation and integrates easily into compact control panels.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338865947,"sku":"1SVR550801R9300","price":40.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550801r9300-cm-mse-ac-ptc-relay_99e28858-794c-4cdf-8f5c-bab8bbd6281a.webp?v=1777160730"},{"product_id":"abb-1svr550805r9300-cm-mse-thermistor-motor-protection-relay","title":"ABB 1SVR550805R9300 CM-MSE Thermistor Motor Protection Relay 1NO 24VAC Relay for Thermistor Protection (PTC)","description":"\u003cp\u003eThe ABB CM-MSE (SKU: 1SVR550805R9300) is a thermistor motor protection relay (PTC) designed to protect electric motors from overtemperature damage by monitoring PTC thermistor sensors embedded in the motor windings. Rated at 4 A \/ 250 V with a 24 VAC supply and a single normally-open (1NO) output contact, the CM-MSE delivers reliable thermal protection in compact 22.5 mm DIN-rail format for control panels and industrial automation systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-MSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR550805R9300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay for Thermistor Protection (PTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 × 78 × 78.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.105 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614348761\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecUL:\u003c\/strong\u003e Canadian UL recognition for industrial control use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified to Canadian Standards Association requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU directives for electrical safety and EMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed for post-Brexit Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for import and sale in China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor thermal protection in industrial drives and motor starters\u003c\/li\u003e\n\u003cli\u003eIntegration with PTC thermistor sensors embedded in motor windings\u003c\/li\u003e\n\u003cli\u003eControl panel automation circuits requiring compact DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003eHVAC, pump, compressor, and conveyor motor protection\u003c\/li\u003e\n\u003cli\u003eOEM machinery requiring UL508 \/ CSA certified thermistor monitoring relays\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat sensor type does the CM-MSE work with?\u003c\/strong\u003e\u003cbr\u003eThe CM-MSE is designed exclusively for PTC (Positive Temperature Coefficient) thermistors embedded in motor windings, triggering the output contact when sensor resistance indicates an overtemperature condition.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the supply voltage of the CM-MSE?\u003c\/strong\u003e\u003cbr\u003eThe relay for thermistor protection CM-MSE operates on a 24 VAC control supply voltage.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat output configuration does the CM-MSE provide?\u003c\/strong\u003e\u003cbr\u003eIt provides one normally-open (1NO) output contact rated at 4 A \/ 250 V for integration into motor control or alarm circuits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229338964251,"sku":"1SVR550805R9300","price":40.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr550805r9300-cm-mse-thermistor-protection-ptc_b6354b6f-857c-43a8-8232-a24a332c0d50.webp?v=1777160735"},{"product_id":"abb-1svr730660r0100-cm-iws-1s-insulation-monitoring-relay","title":"ABB 1SVR730660R0100 CM-IWS.1S Insulation and Earth Fault Monitoring Relay 1 C\/O 1-100kΩ 24-240VAC\/DC","description":"\u003cp\u003eThe ABB CM-IWS.1S insulation and earth fault monitoring relay (SKU: 1SVR730660R0100) continuously monitors insulation resistance in ungrounded AC and DC systems, tripping its 1 change-over (C\/O) output when resistance falls below a user-selectable threshold between 1 and 100 kΩ. Designed for demanding industrial control panel environments, the CM-IWS.1S operates across a wide supply voltage range of 24–240 V AC\/DC, making it a versatile choice for global applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWS.1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730660R0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation and Earth Fault Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (change-over)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm × 85.6 mm × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.148 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852609\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-1:\u003c\/strong\u003e General requirements for measuring equipment for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems (EN harmonised)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61326-2-4:\u003c\/strong\u003e EMC requirements for portable test and measurement equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for evaluation of electrical and electronic products with respect to hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Standard for industrial control equipment (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment (Canada)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Listed for both US (UL) and Canadian (CSA) markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances — compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eContinuous insulation monitoring in ungrounded (IT) AC and DC power systems\u003c\/li\u003e\n\u003cli\u003eEarth fault detection in industrial machinery and control panels\u003c\/li\u003e\n\u003cli\u003eProtection of medical, marine, and process plant electrical installations\u003c\/li\u003e\n\u003cli\u003eEarly warning systems preventing unplanned shutdowns due to insulation degradation\u003c\/li\u003e\n\u003cli\u003eBuilding automation and infrastructure applications requiring 24–240 V AC\/DC flexibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229339226395,"sku":"1SVR730660R0100","price":178.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730660r0100-cm-iws-1s-c-o-1-100k-24-240vac-dc_3d618511-d0c6-41ab-86e5-e3e2073fa740.webp?v=1777160802"},{"product_id":"abb-1svr750660r0200-cm-iwn-1s-insulation-monitoring-relay","title":"ABB 1SVR750660R0200 CM-IWN.1S Insulation and Earth Fault Monitoring Relay 2 C\/O 1-100kΩ 24-240VAC\/DC","description":"\u003cp\u003eThe ABB CM-IWN.1S insulation and earth fault monitoring relay (SKU: 1SVR750660R0200) continuously monitors insulation resistance in unearthed AC and DC systems, providing two changeover output contacts and a wide supply voltage range of 24–240 VAC\/DC. Part of the CM-IWN series, the CM-IWN.1S is designed for industrial control panels, machinery, and critical electrical installations where early detection of insulation degradation is essential to prevent equipment damage and personnel hazards. Its compact 45 mm × 85.6 mm × 104.8 mm DIN-rail housing makes it suitable for space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWN.1S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR750660R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWN\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation and Earth Fault Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 C\/O (2 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2–200 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm × 85.6 mm × 104.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.241 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-1:\u003c\/strong\u003e General requirements for electrical safety in low-voltage distribution systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems (EN harmonised)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61326-2-4:\u003c\/strong\u003e EMC requirements for equipment used in industrial locations — particular requirements for insulation monitoring devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61326-2:\u003c\/strong\u003e EMC — immunity requirements for industrial electromagnetic environments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61326-2:\u003c\/strong\u003e EMC for measurement, control and laboratory equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61557-1:\u003c\/strong\u003e Electrical safety in LV distribution systems — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems (EN)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60715:\u003c\/strong\u003e Dimensions of low-voltage switchgear and controlgear — standardised mounting on rails\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment (USA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment (Canada)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL recognised for both US and Canadian markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous insulation resistance monitoring in unearthed (IT) AC and DC power systems\u003c\/li\u003e\n  \u003cli\u003eEarly fault detection in industrial machinery, control panels, and process automation systems\u003c\/li\u003e\n  \u003cli\u003eProtection of medical equipment power supplies and operating theatre electrical systems\u003c\/li\u003e\n  \u003cli\u003eMonitoring of photovoltaic (PV) and battery energy storage DC systems\u003c\/li\u003e\n  \u003cli\u003eAlarm and shutdown triggering in offshore, marine, and mining electrical installations\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and critical infrastructure panels requiring IEC 61557-8 compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229340471579,"sku":"1SVR750660R0200","price":391.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr750660r0200-cm-iwn-1s-c-o-1-100k-24-240vac-dc_87fcabf0-8bfe-4d9c-9dc1-0efd0bbc0595.webp?v=1777160902"},{"product_id":"abb-1svr730670r0200-cm-iws-2s-insulation-monitoring-relay","title":"ABB 1SVR730670R0200 CM-IWS.2S Insulation and Earth Fault Monitoring Relay 1 C\/O 1-100kΩ 24-240VAC\/DC","description":"\u003cp\u003eThe ABB CM-IWS.2S insulation and earth fault monitoring relay (SKU: 1SVR730670R0200) continuously monitors the insulation resistance of unearthed AC, DC, and mixed electrical systems, providing a single changeover (1 C\/O) output contact when insulation resistance falls below the set threshold. Designed for control panels and industrial automation environments, the CM-IWS.2S supports a wide monitoring range of 1–100 kΩ and operates across a broad supply voltage range of 24–240V AC\/DC, making it suitable for diverse global applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWS.2S\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SVR730670R0200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM-IWS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation and Earth Fault Monitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 C\/O (1 changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm × 85.6 mm × 103.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.141 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779852616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61557-8:\u003c\/strong\u003e Insulation fault location in IT systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-1:\u003c\/strong\u003e General requirements for measuring and monitoring devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 63000:\u003c\/strong\u003e Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61326-2-4:\u003c\/strong\u003e EMC requirements for equipment used in industrial locations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 63000:\u003c\/strong\u003e European harmonised standard for RoHS technical documentation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61326-2:\u003c\/strong\u003e EMC requirements — particular requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61557-1:\u003c\/strong\u003e Measuring and monitoring devices — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61557-8:\u003c\/strong\u003e Insulation monitoring devices for IT systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial control equipment (USA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCAN\/CSA C22.2 No.14:\u003c\/strong\u003e Industrial control equipment (Canada)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e Combined UL and CSA mark for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for the British market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on chemicals — compliance confirmed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous insulation resistance monitoring in unearthed IT power systems\u003c\/li\u003e\n  \u003cli\u003eEarth fault detection in industrial control panels and switchgear\u003c\/li\u003e\n  \u003cli\u003eProtection of machines, motors, and generators in manufacturing environments\u003c\/li\u003e\n  \u003cli\u003eBuilding automation systems requiring wide-range voltage monitoring\u003c\/li\u003e\n  \u003cli\u003eMedical, offshore, and critical infrastructure installations demanding high electrical safety\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229340602651,"sku":"1SVR730670R0200","price":138.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1svr730670r0200-cm-iws-2s-c-o-1-100k-24-240vac-dc_d43547ec-b9d1-4a93-adf8-8311a05e0bfb.webp?v=1777160807"},{"product_id":"schneider-rm17jc00mw-harmony-5a-1co-250v-current-control-relay","title":"Schneider Electric RM17JC00MW Harmony Control Relay 1CO 5A 250V AC\/DC Current Control Relay","description":"\u003cp\u003eThe Schneider Electric RM17JC00MW is a Harmony series current control relay designed for industrial automation and control panel applications. Rated at 5A with a 250V AC\/DC operating voltage and a 1CO (1 changeover) contact configuration, this compact relay delivers reliable current monitoring and switching in a 0.13 kg package suitable for DIN rail installation. Ideal for protecting motors, transformers, and process equipment against abnormal current conditions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM17JC00MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1CO (1 Changeover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Monitors load current to detect overload or underload conditions in motor drive circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Ensures continuous current supervision in automated production lines and control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Monitoring:\u003c\/strong\u003e Detects dry-run or blockage conditions through current threshold monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Provides current-based fault detection for fans, pumps, and compressors in building management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Industrial Control:\u003c\/strong\u003e Suitable for any control panel application requiring precise current level supervision up to 250V AC\/DC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229834318107,"sku":"RM17JC00MW","price":156.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm17jc00mw-current-control-relay_c35a827a-2c05-4722-bb51-b3f455e57e14.jpg?v=1777166769"},{"product_id":"schneider-rm17ta00-harmony-3-phase-control-relay-1co-5a","title":"Schneider Electric RM17TA00 Harmony Relay 3-Phase Control Relay 1CO 5A 208-480V AC","description":"\u003cp\u003eThe Schneider Electric RM17TA00 is a Harmony series 3-phase control relay designed for monitoring and control applications in industrial automation systems. Rated at 5A with a 1CO output contact and a wide operating voltage range of 208–480V AC, the RM17TA00 provides reliable phase monitoring and protection for motors, control panels, and process equipment. Weighing just 0.13 kg, this compact relay integrates easily into DIN rail-mounted control panel assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM17TA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Monitors 3-phase power supply integrity to prevent motor damage from phase loss, phase imbalance, or incorrect phase sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Used in automated manufacturing lines and process control systems requiring reliable phase supervision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panels:\u003c\/strong\u003e Compact 0.13 kg form factor suits space-constrained DIN rail panel builds in switchboards and MCC cubicles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Pump Systems:\u003c\/strong\u003e Protects 3-phase-driven compressors, pumps, and fans operating on 208–480V AC supply networks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229834416411,"sku":"RM17TA00","price":120.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm17ta00-5a-208-480v-ac_23075cfc-6f47-4b5f-aef6-c30ec8f01a19.jpg?v=1777166773"},{"product_id":"schneider-rm17tg00-harmony-3-phase-control-relay-5a","title":"Schneider Electric RM17TG00 Harmony Relay 3-Phase Control Relay 5A 208-480V AC","description":"\u003cp\u003eThe Schneider Electric RM17TG00 is a Harmony series 3-phase control relay designed for reliable phase monitoring and control in industrial automation systems. Rated at 5A with a wide operating voltage range of 208 to 480V AC, the RM17TG00 is engineered for integration into control panels and motor protection circuits where precise 3-phase supervision is critical. Compact and lightweight at just 130g, this relay suits demanding panel-building environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM17TG00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208...480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229834711323,"sku":"RM17TG00","price":102.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm17tg00-5a-208-480v-ac_71239f6a-1416-45f1-8ce0-21798bb4f0ef.jpg?v=1777166778"},{"product_id":"schneider-rm17tg20-harmony-3-phase-control-relay-5a","title":"Schneider Electric RM17TG20 Harmony 3-Phase Control Relay 5A 208-480V AC","description":"\u003cp\u003eThe Schneider Electric RM17TG20 is a Harmony series 3-phase control relay rated at 5A and designed for 208–480V AC supply voltages, making it a versatile solution for monitoring and protecting three-phase electrical systems in industrial automation environments. The RM17TG20 provides reliable phase sequence and phase loss detection, helping safeguard motors and other connected equipment in control panels and automation installations. Weighing just 0.13 kg, its compact form factor supports easy DIN rail integration.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM17TG20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Monitors three-phase supply integrity to protect motors from phase loss, phase imbalance, and incorrect phase sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Integrates into control panels and automation systems requiring reliable three-phase supply monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact DIN rail design suits both OEM machine builders and panel integrators working with 208–480V AC networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Systems:\u003c\/strong\u003e Protects rotating machinery from damaging single-phase conditions in industrial plant environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229834842395,"sku":"RM17TG20","price":108.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm17tg20-5a-208-480v-ac_f02c93f4-0e37-47f2-81eb-456d05e2d38a.jpg?v=1777166782"},{"product_id":"schneider-electric-rm22la32mr-level-control-relay","title":"Schneider Electric RM22LA32MR Harmony RM22L 8A 2CO Level Control 24-240V AC\/DC Control Relay","description":"\u003cp\u003eThe Schneider Electric RM22LA32MR is a Harmony RM22L level control relay that detects liquid level through resistive probes and switches 2 C\/O contacts rated 8 A. It runs from a universal 24-240 V AC\/DC 50\/60 Hz supply, offers an adjustable 0.1-30 second fault time delay, and mounts on 35 mm DIN rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eRM22LA32MR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRM22L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLevel control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameter\u003c\/td\u003e\n\u003ctd\u003eLevel, by resistive probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Nominal Voltage (Un)\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\/DC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...264 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay (fault)\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.1...30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd\u003e8 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.25...1000 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity Scale\u003c\/td\u003e\n\u003ctd\u003e0.25...5 kOhm (LS) \/ 5...100 kOhm (St) \/ 50...1000 kOhm (HS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance (probe)\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Electrode Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals) \/ IP40 (housing) \/ IP50 (front panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Reliability Data\u003c\/td\u003e\n\u003ctd\u003eMTTFd = 182.6 years, B10d = 170000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eIEC 60255-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRM22LA32MR detects liquid level through resistive probes rather than a float switch, which suits tanks where mechanical floats foul or where several fixed level points must be sensed. The LS\/St\/HS sensitivity scale (0.25 kOhm to 1000 kOhm) is set to match probe cable length and liquid conductivity, with runs up to 100 m supported. At 8 A\/2 C\/O on a 24-240 V AC\/DC supply, it can switch a pump contactor coil directly from the panel's control voltage without an interposing relay.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229836316955,"sku":"RM22LA32MR","price":74.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm22la32mr-rm22l-control-relay.jpg?v=1790282815"},{"product_id":"schneider-electric-rm35ba10-pump-control-relay","title":"Schneider Electric RM35BA10 Harmony RM35BA Pump 5A 1CO 208-480V AC Control Relay","description":"\u003cp\u003eThe Schneider Electric RM35BA10 is a Harmony RM35BA pump control relay that monitors overcurrent, undercurrent, phase sequence and phase failure on 3-phase or single-phase pump supplies. It switches a single 5 A C\/O contact, measures 1-10 A current and 208-480 V AC voltage, and mounts on 35 mm DIN rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eRM35BA10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRM35BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePump control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameters\u003c\/td\u003e\n\u003ctd\u003eOvercurrent\/undercurrent, phase sequence, phase failure (3-phase and single-phase pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts\u003c\/td\u003e\n\u003ctd\u003e1 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e1...10 A \/ 208...480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Nominal Voltage (Un)\u003c\/td\u003e\n\u003ctd\u003e208...480 V AC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e183...528 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay\u003c\/td\u003e\n\u003ctd\u003eAdjustable 1...60 s (startup inhibition, Ti) \/ 0.1...10 s (fault, Tt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Input Current\u003c\/td\u003e\n\u003ctd\u003e11 A permanent \/ 50 A non-repetitive \u0026lt; 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 300 ms (fault event)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals) \/ IP30 (casing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-tick\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eIEC 60255-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRM35BA10's 1-10 A measurement range on the pump's current line catches both dry-running (undercurrent) and blocked-rotor\/overload (overcurrent) faults with one relay, plus phase sequence and phase-loss on the 3-phase supply - four failure modes without four separate devices. The 11 A permanent overload input current rating means the sensing input tolerates sustained overcurrent faults through the 1-60 s startup inhibition window without damage. Its 208-480 V AC measurement range covers both 230\/400 V and 460\/480 V motor supplies from one part.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229836579099,"sku":"RM35BA10","price":102.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35ba10-rm35ba-pump-relay.jpg?v=1790282821"},{"product_id":"schneider-electric-rm35ja32mw-current-control-relay","title":"Schneider Electric RM35JA32MW Harmony RM35JA 5A 2CO 0.15-15A 24-240V AC\/DC Control Relay","description":"\u003cp\u003eThe Schneider Electric RM35JA32MW is a Harmony RM35JA current control relay that detects overcurrent or undercurrent on single-phase circuits from 150 mA to 15 A. It switches 2 C\/O contacts rated 5 A from a universal 24-240 V AC\/DC 50\/60 Hz supply and mounts on 35 mm DIN rail. Threshold and hysteresis are field-adjustable.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eRM35JA32MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRM35JA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCurrent control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameter\u003c\/td\u003e\n\u003ctd\u003eOvercurrent or undercurrent detection (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e150 mA...15 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage (Us)\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\/DC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...264 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.3...30 s (fault, Tt) \/ 1...20 s (startup inhibition, Ti)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003e5...50% of threshold setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThreshold Setting\u003c\/td\u003e\n\u003ctd\u003e10...100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals) \/ IP30 (casing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eC-tick\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eIEC 60255-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRM35JA32MW's 150 mA-15 A measurement window spans light-load to full-load single-phase currents, so the same part covers small fan motors and larger single-phase pumps by adjusting the threshold (10-100%) and hysteresis (5-50%) rather than swapping relays. Its 2 C\/O output, versus RM35BA10's single contact, lets one contact drive an alarm circuit while the other trips the load contactor. The startup inhibition delay (1-20 s) rides through motor inrush before undercurrent tripping is armed.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229836939547,"sku":"RM35JA32MW","price":140.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35ja32mw-rm35ja-control-relay.jpg?v=1790282829"},{"product_id":"schneider-electric-rm35lm33mw-level-control-relay","title":"Schneider Electric RM35LM33MW Harmony RM35L 5A 2CO Level Control 24-240V AC\/DC Control Relay","description":"\u003cp\u003eThe Schneider Electric RM35LM33MW is a Harmony RM35L level control relay that detects liquid level via resistive probes in 3-phase-supplied installations and switches 2 C\/O contacts rated 5 A. It runs from a universal 24-240 V AC\/DC 50\/60 Hz supply, offers an adjustable 0.1-5 second fault time delay, and mounts on 35 mm DIN rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eRM35LM33MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRM35L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLevel control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameter\u003c\/td\u003e\n\u003ctd\u003eLevel, by resistive probes (3-phase networks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts\u003c\/td\u003e\n\u003ctd\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.25...1000 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Nominal Voltage (Un)\u003c\/td\u003e\n\u003ctd\u003e24...240 V AC\/DC 50\/60 Hz, non self-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e20.4...264 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay (fault)\u003c\/td\u003e\n\u003ctd\u003eAdjustable 0.1...5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity Scale\u003c\/td\u003e\n\u003ctd\u003e0.25...5 kOhm (LS) \/ 5...100 kOhm (St) \/ 50...1000 kOhm (HS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Distance (probe)\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (terminals) \/ IP30 (casing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003e35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Reliability Data\u003c\/td\u003e\n\u003ctd\u003eMTTFd = 182.6 years, B10d = 170000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eGL\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eC-tick\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003cli\u003eIEC 60255-6\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRM35LM33MW monitors liquid level via resistive probes on 3-phase-supplied installations, using the same LS\/St\/HS sensitivity scale (0.25 kOhm to 1000 kOhm) and 100 m probe cable limit as the other Harmony RM35 measurement relays, so probes sized for one RM35 part carry over to another. Its 0.1-5 s fault time delay is short enough for fast dry-run alarms, and the 2 C\/O output at 5 A lets one contact drive an alarm circuit while the other trips the load.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229837070619,"sku":"RM35LM33MW","price":76.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35lm33mw-rm35l-control-relay.jpg?v=1790282835"},{"product_id":"schneider-rm35tf30-harmony-3-phase-supply-control-relay","title":"Schneider Electric RM35TF30 Harmony Relay 3-Phase Supply Control Relay 220-480VAC","description":"\u003cp\u003eThe Schneider Electric RM35TF30 Harmony Relay is a 3-phase supply control relay designed for industrial automation and control panel applications. Operating across a wide rated voltage range of 220 to 480 V AC, the RM35TF30 provides reliable monitoring and protection of 3-phase electrical supplies, making it an essential component for safeguarding motors, machinery, and industrial processes against phase faults.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM35TF30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Supply Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 to 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase Motor Protection:\u003c\/strong\u003e Monitors 3-phase supply integrity to protect motors from phase loss, phase imbalance, and incorrect phase sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Integrates into control panels and switchgear assemblies for continuous supply supervision in manufacturing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Used in industrial automation applications where reliable 3-phase power quality monitoring is critical for process continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; Compressor Systems:\u003c\/strong\u003e Protects rotating equipment by detecting supply anomalies before damage can occur.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229837267227,"sku":"RM35TF30","price":182.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35tf30-control-relay-220-480vac_cd25291b-60a3-4130-82e0-b7dc018a9a89.jpg?v=1777166786"},{"product_id":"schneider-rm35tm50mw-ssd1-3-phase-control-relay-5a","title":"Schneider Electric RM35TM50MW SSD1 3-Phase Control Relay 5A 24-240V AC\/DC Harmony Series","description":"\u003cp\u003eThe Schneider Electric RM35TM50MW is a Harmony Series SSD1 3-phase control relay rated at 5A with a wide supply voltage range of 24–240V AC\/DC, designed for reliable phase monitoring and protection in industrial automation and control panel applications. This versatile relay detects phase loss, phase imbalance, and incorrect phase sequence, safeguarding three-phase equipment from potentially damaging electrical faults. Compact and DIN-rail mountable, the RM35TM50MW is a trusted choice for engineers specifying motor and load protection solutions across diverse industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM35TM50MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSSD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Control Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–240V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.298 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e Monitors three-phase supplies to detect phase loss, imbalance, or incorrect phase sequence before motors are energised, preventing winding damage and costly downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Compact DIN-rail form factor makes the RM35TM50MW straightforward to integrate into standard industrial control panels and switchboards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for production lines, HVAC systems, pumping stations, and conveyor drives where reliable three-phase supply integrity is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e The 24–240V AC\/DC rated voltage range allows a single relay type to cover a broad range of global supply standards, simplifying spares inventory.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229837431067,"sku":"RM35TM50MW","price":136.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rm35tm50mw-ac-dc-harmony-series_c24bab4e-018e-4502-8f03-235789576fb3.jpg?v=1777166791"},{"product_id":"siemens-3rq4018-1ab00-3rq4-6a-24v-relay","title":"Siemens 3RQ4018-1AB00 3RQ4 6A 24V Relay","description":"\u003cp\u003eThe Siemens 3RQ4018-1AB00 is a relay from the SENTRON\/SIRIUS 3RQ4 series. Output coupler with integrated relay, 24 V AC\/DC, 1 change-over contact, screw terminal, width 6.2 mm, thermal current 6 A. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4018-1AB00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay version LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSemi-conductor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [W] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed active power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween control and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePercental drop-out voltage related to the input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlammability class of enclosure material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esinusoidal half-wave 15 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 ... 150 Hz: 2 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 000 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emonostable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical service life (operating cycles) typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-15 at 250 V typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.037 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.037 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 60947-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RQ4018-1AB00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RQ4 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620021924123,"sku":"3RQ4018-1AB00","price":28.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rq4018-1ab00.webp?v=1784376614"},{"product_id":"siemens-3rq4018-1af00-3rq4-6a-230v-relay","title":"Siemens 3RQ4018-1AF00 3RQ4 6A 230V Relay","description":"\u003cp\u003eThe Siemens 3RQ4018-1AF00 is a relay from the SENTRON\/SIRIUS 3RQ4 series. Output coupler with integrated relay, 230 V AC\/DC, 1 change-over contact, screw terminal, width 6.2 mm, thermal current 6 A. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4018-1AF00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay version LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSemi-conductor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [W] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed active power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween control and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePercental drop-out voltage related to the input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlammability class of enclosure material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esinusoidal half-wave 15 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 ... 150 Hz: 2 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 000 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emonostable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical service life (operating cycles) typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-15 at 250 V typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.039 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.039 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 60947-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RQ4018-1AF00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RQ4 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620021956891,"sku":"3RQ4018-1AF00","price":30.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rq4018-1af00.webp?v=1784376620"},{"product_id":"siemens-3rq4018-2am08-0aa0-3rq4-6a-24v-relay","title":"Siemens 3RQ4018-2AM08-0AA0 3RQ4 6A 24V Relay","description":"\u003cp\u003eThe Siemens 3RQ4018-2AM08-0AA0 is a relay from the SENTRON\/SIRIUS 3RQ4 series. Output coupler with integrated relay, 24 V DC (0.7-1.25 x Us), 1 change-over contact, spring-loaded terminal (push-in), width 6.2 mm, thermal current 6 A. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4018-2AM08-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay version LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSemi-conductor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [W] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed active power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween control and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePercental drop-out voltage related to the input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlammability class of enclosure material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor railway applications according to EN 61373\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 1, Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 000 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emonostable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical service life (operating cycles) typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-15 at 250 V typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.035 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl supply voltage at DC rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.035 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 50121-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RQ4018-2AM08-0AA0 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RQ4 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620021989659,"sku":"3RQ4018-2AM08-0AA0","price":20.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rq4018-2am08-0aa0.webp?v=1784376626"},{"product_id":"siemens-3rq4038-1ab00-3rq4-6a-24v-relay","title":"Siemens 3RQ4038-1AB00 3RQ4 6A 24V Relay","description":"\u003cp\u003eThe Siemens 3RQ4038-1AB00 is a relay from the SENTRON\/SIRIUS 3RQ4 series. Input coupler with integrated relay, 24 V AC\/DC, 1 change-over contact, screw terminal, width 6.2 mm, thermal current 6 A. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4038-1AB00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RQ4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay version LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSemi-conductor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss [W] maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumed active power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge voltage resistance rated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetween control and auxiliary circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePercental drop-out voltage related to the input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlammability class of enclosure material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esinusoidal half-wave 15 g \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccording to IEC 60068-2-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 ... 150 Hz: 2 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating frequency maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 000 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emonostable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical service life (operating cycles) typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-15 at 250 V typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.039 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.039 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEN 60947-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RQ4038-1AB00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RQ4 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52620022022427,"sku":"3RQ4038-1AB00","price":33.19,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3rq4038-1ab00.webp?v=1784376632"}],"url":"https:\/\/stoklink.com\/collections\/monitoring-relays.oembed","provider":"Stoklink","version":"1.0","type":"link"}